Finding | |
|---|---|
| Title | Failure to Make Eight Hour Report Pursuant to 10 CFR 50.72 |
| Description | The inspectors identified a Severity Level IV NCV of 10 CFR 50.72(b)(3)(v)(D) for the licensees failure to report an event or condition that could have prevented the fulfillment of a safety function to the NRC within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />. Specifically, on June 27, 2011, an unexpected lockout of the 2RY transformer rendered one of two required offsite power paths inoperable. A subsequent review of the remaining transmission system capabilities resulted in declaring the second offsite power path inoperable due to inadequate minimum post-trip voltage. However, the licensee failed to recognize that the inoperability of both offsite power paths constituted a loss of safety function that was reportable to the NRC within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />. The licensee initiated a corrective action document, CAP 1292940, for this issue. Corrective actions for this issue included reporting this issue to the NRC on July 1, 2011, revising procedures to ensure that inoperable offsite power paths that remain available were reported to the NRC, and repairing the 2RY transformer. The inspectors determined that the failure to report required plant events or conditions to the NRC had the potential to impede or impact the regulatory process. As a result, the NRC dispositions violations of 10 CFR 50.72 using the traditional enforcement process instead of the SDP. However, if possible, the underlying technical issue was evaluated using the SDP. In this case, the inspectors determined that the 2RY transformer locked out due to moisture entering a degraded bus duct, which was exposed to the environment. The licensee failed to identify the degraded bus duct earlier due to the inappropriate deferral of preventive maintenance activities. The inspectors determined that this issue was more than minor because it was associated with the protection against external factors attribute of the Initiating Events Cornerstone, and affected the cornerstone objective of limiting the likelihood of those events that upset plant stability and challenge critical safety functions during power operations. Since the finding contributed to both the likelihood of a plant trip and that mitigating systems equipment or functions would not be available, a Region III Senior Reactor Analyst (SRA) was contacted for assistance. The results of the Phase 3 analysis showed a change in core damage frequency of 2.4E-8/year, which represented a finding of very low safety significance (Green). In accordance with Section 6.1.d.2 of the NRC Enforcement Policy, this violation was categorized as Severity Level IV because the underlying technical issue was evaluated by the SDP and determined to be of very low safety significance. The inspectors concluded that this finding was cross-cutting in the Human Performance, Work Practices area because licensee personnel failed to follow procedures regarding the preventive maintenance deferral process. |
| Site: | Prairie Island |
|---|---|
| Report | IR 05000282/2011004 Section 4OA3 |
| Date counted | Sep 30, 2011 (2011Q3) |
| Type: | Finding: Green |
| cornerstone | Initiating Events |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71153 |
| Inspectors (proximate) | C Zoia D Betancourt J Beavers J Giessner K Stoedter M Phalen N Feliz Adorno P Cardona Morales P Elkmann P Zurawski S Shah V Meghani |
| CCA | H.8, Procedure Adherence |
| INPO aspect | WP.4 |
| ' | |
Finding - Prairie Island - IR 05000282/2011004 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Prairie Island) @ 2011Q3
Self-Identified List (Prairie Island)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||