05000272/LER-1981-112, Forwards LER 81-112/03L-0.Detailed Event Analysis Encl

From kanterella
Jump to navigation Jump to search
Forwards LER 81-112/03L-0.Detailed Event Analysis Encl
ML20038D028
Person / Time
Site: Salem 
Issue date: 12/02/1981
From: Midura H
Public Service Enterprise Group
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20038D029 List:
References
NUDOCS 8112140352
Download: ML20038D028 (3)


LER-1981-112, Forwards LER 81-112/03L-0.Detailed Event Analysis Encl
Event date:
Report date:
2721981112R00 - NRC Website

text

~

" O PSEG Public Service Electric and Gas Company P.O. Box 168 Hancocks Bridge, New Jersey 08038 Salem Generating Station December 2, 1981

<,9

%)

l'e Mr.

R.

C.

Haynes c

Director of USNRC 5

4s C

Office of Inspection and Enforcement

,[/

j, Region 1

/ Ll

'( j 631 Park Avenue 7

g,' O,

King of Prussia, Pennsylvania 19406 Q,

Dear Mr. Haynes:

LICENSE NO. DPR-70 DOCKET NO. 50-272 REPORTABLE OCCURRENCE 81-112/03L Pursuant to the requirements of Salem Generating Station Unit No.

1, Technical Specifications, Section 6.9.1.9.b, we are submitting Licensee Event Report for Reportable Occurrence 81-ll2/03L.

This report is required within thirty (30) days of the occurrence.

Sincerely yours, flC, bt -e YwuJ H.

J.

Midura l

General Manager -

l Salem Operations 1

I CC:

Distribution 8112140352 811202 PDR ADOCK 05000272 S

PDR g) l 51 l

. n.

s Report Number:

91-112/03L Report Date:

12-2-81 Occurrence Date:

11-6-81 Facility:

Salem Generating Station, Unit 1 Public Service Electric & Gas Company Hancocks Bridge, New Jersey 08038 IDENTIFICATION OF OCCURRENCE:

Auxiliary Feed Storage Tank - Low Level This report was initiated by Incident Report 81-448.

CONDITIONS PRIOR TO OCCURRENCE:

Mode 3 - Rx Power 0% - Unit Load 0 MWe.

DESCRIPTION OF OCCURRENCE:

On November 6, 1981 during recovery actions from a reactor trip, the Auxiliary Feed Storage Tank (AFST) was observed to be below the minimum level required by the technical specifications.

At 1353 hours0.0157 days <br />0.376 hours <br />0.00224 weeks <br />5.148165e-4 months <br />, the AFST was declared inoperable and Action Statement 3.7.1.3.a was entered.

This occurrence constituted operation in a degraded mode in accordance with Technical Specification 6.9.1.9.b.

DESIGNATION OF APPARENT CAUSE OF OCCURRENCE:

The cause of the low level in the AFST was the feeding of the steam generators with auxiliary feedwater following a reactor trip at 1330 hours0.0154 days <br />0.369 hours <br />0.0022 weeks <br />5.06065e-4 months <br />.

ANALYSIS OF OCCURRENCE:

Technical Specification 3.7.1.3.a requires:

With the Auxiliary Feed Storage Tank inoperable, within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> restore to operable or be in hot shutdown within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

CORRECTIVE ACTION

Demineralized water makeup was initiated and the proper level was restored in the AFST.

The AFST was declared operable and Action Statement 3.7.1.3.a was terminated at 1630 hours0.0189 days <br />0.453 hours <br />0.0027 weeks <br />6.20215e-4 months <br />.

.,LER 81-112/03L '

FAILURE DATA:

Not Applicable

/dh k[hdh Prepared By K. Whitcomb Gene'ral Manager -

~

Salem Operations SORC Meeting No.81-123