Category:INSPECTION REPORT
MONTHYEARIR 05000266/19990151999-09-30030 September 1999 Insp Repts 50-266/99-15 & 50-301/99-15 on 990830-0903.No Violations Noted.Major Areas Inspected:Operations & Training IR 05000266/19990131999-09-29029 September 1999 Insp Repts 50-266/99-13 & 50-301/99-13 on 990714-0830.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000266/19990141999-08-31031 August 1999 Insp Repts 50-266/99-14 & 50-301/99-14 on 990726-30.No Violations Noted.Major Areas Inspected:Access Authorization Program,Alarm Stations & Communications.Security Mgt Also Inspected IR 05000266/19990091999-07-28028 July 1999 Insp Repts 50-266/99-09 & 50-301/99-09 on 990528-0713. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000266/19990121999-07-14014 July 1999 Insp Repts 50-266/99-12 & 50-301/99-12 on 990614-18.No Violations Noted.Major Areas Inspected:Implementation of Inservice Test Program & MOVs Capability,Per GL 96-05 IR 05000266/19990081999-06-18018 June 1999 Insp Repts 50-266/99-08 & 50-301/99-08 on 990411-0527.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19990061999-05-0707 May 1999 Insp Repts 50-266/99-06 & 50-301/99-06 on 990223-0410. Non-cited Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19990051999-04-20020 April 1999 Insp Repts 50-266/99-05 & 50-301/99-05 on 990222-0312. Violations Noted.Major Areas Inspected:Effectiveness & Engineering & Technical Support Organization in Performance of Routine & Reactive Site Activities & Problem Prevention IR 05000266/19990101999-04-19019 April 1999 Insp Repts 50-266/99-10 & 50-301/99-10 on 990329-0401.No Violations Noted.Major Areas Inspected:Review of Emergency Preparedness Program & Aspect of Plant Support IR 05000266/19990071999-03-16016 March 1999 Insp Repts 50-266/99-07 & 50-301/99-07 on 990216-19.No Violations Noted.Major Areas Inspected:Routine Insp of Radiation Protection & Chemistry Program Which Included Water Chemistry Control Program ML20204D8311999-03-12012 March 1999 Insp Rept 50-266/99-04 on 990105-0222.One Violations of NRC Requirements Occurred & Being Treated as non-cited Violation.Major Areas Inspected:Operations,Maint & Engineering IR 05000266/19990021999-03-10010 March 1999 Insp Repts 50-266/99-02 & 50-301/99-02 on 990105-0222. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000266/19990031999-02-0101 February 1999 Insp Repts 50-266/99-03 & 50-301/99-03 on 990111-15.No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Relating to Physical Protection of Facility IR 05000266/19980211999-01-15015 January 1999 Insp Repts 50-266/98-21 & 50-301/98-21 on 981121-990104. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19980221998-12-24024 December 1998 Insp Repts 50-266/98-22 & 50-301/98-22 on 981208-10.No Violations Noted.Major Areas Inspected:Maint Rule Program IR 05000206/19980191998-12-0404 December 1998 Insp Repts 50-206/98-19 & 50-301/98-19 on 981004.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000266/19980201998-11-30030 November 1998 Insp Rept 50-266/98-20 & 50-301/98-20 on 981102-06.No Violations Noted.Major Areas Inspected:Plant Biennial Exercise of Emergency Plan IR 05000266/19980171998-10-26026 October 1998 Insp Repts 50-266/98-17 & 50-301/98-17 on 980818-1005.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980181998-10-0202 October 1998 Insp Repts 50-266/98-18 & 50-301/98-18 on 980831-0904.No Violations Noted.Major Areas Inspected:Radiation Protection Program,Including Review of Whole Body Counter Calibration, Portable Instrument Calibration & Routine Contamination IR 05000266/19980151998-09-11011 September 1998 Insp Repts 50-266/98-15 & 50-301/98-15 on 980720-31.No Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training & Supporting Documentation to Ensure TS Required Surveillance Testing IR 05000266/19980131998-09-11011 September 1998 Insp Repts 50-266/98-13 & 50-301/98-13 on 980608-12 & 0715-16.Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training,Equipment & Supporting Documentation for Maint of Medium Voltage & Low Voltage IR 05000266/19980141998-09-0303 September 1998 Insp Repts 50-266/98-14 & 50-301/98-14 on 980707-0817.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980161998-08-10010 August 1998 Insp Repts 50-266/98-16 & 50-301/98-16 on 980713-17.No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility ML20236V6621998-07-29029 July 1998 Insp Repts 50-266/98-11 & 50-301/98-11 on 980526-0706. No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980091998-06-19019 June 1998 Insp Repts 50-266/98-09 & 50-301/98-09 on 980414-0523. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980121998-06-11011 June 1998 Insp Repts 50-266/98-12 & 50-301/98-12 on 980518-22. Violations Noted.Major Areas Inspected:Review of Unit 1 Refueling Outage Doses,Solid Radwaste Mgt,Transportation of Radioactive Matls & Health Physics Program IR 05000266/19980071998-06-0303 June 1998 Insp Rept 50-266/98-07 on 980310-13,16,17,0401-02,22,24 & 0504-05.No Violations Noted.Major Areas Inspected: Maint & Engineeing IR 05000301/19980051998-05-0505 May 1998 Insp Rept 50-301/98-05 on 971216-980309.Violations Noted. Major Areas Inspected:Maint ML20247D2961998-05-0505 May 1998 Insp Repts 50-266/98-06 & 50-301/98-06 on 980303-0413. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000266/19980081998-04-15015 April 1998 Insp Repts 50-266/98-08 & 50-301/98-08 on 980316-20.No Violations Noted.Major Areas Inspected:Radiation Protection Performance During Refueling Outage ML20217J4571998-04-0101 April 1998 Insp Repts 50-266/98-10 & 50-301/98-10 on 980310-18. Violations Noted.Major Areas Inspected:Review of Measuring & Test Equipment Procedures ML20217D3531998-03-21021 March 1998 Insp Repts 50-266/98-03 & 50-301/98-03 on 980120-0302. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19980041998-02-27027 February 1998 Insp Repts 50-266/98-04 & 50-301/98-04 on 980202-06.No Violations Noted.Major Areas Inspected:Review of Health Physics Dept Preparations for Unit 1 Refueling Outage, Including ALARA Planning & Work Planning ML20203D4361998-02-19019 February 1998 Insp Repts 50-266/97-23 & 50-301/97-23 on 971020-1107. Violations Noted.Major Areas Inspected:Licensee Controls in Area of SEs as Well as Effectiveness of Licensee Controls in Identifying,Resolving & Correcting Problems IR 05000266/19970221998-02-18018 February 1998 Insp Repts 50-266/97-22 & 50-301/97-22 on 971104-980203.No Violations Noted.Major Areas Inspected:Review of 20 Licensee Event Repts Submitted Between 960909 & 971215 ML20202E9811998-02-10010 February 1998 Insp Repts 50-266/97-26 & 50-301/97-26 on 971201-980120. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20202E3841998-02-0909 February 1998 Partially Withheld Insp Repts 50-266/98-02 & 50-301/98-02 on 980105-20 (Ref 10CFR73.71).Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility ML20199F1361997-12-22022 December 1997 Insp Repts 50-266/97-21 & 50-301/97-21 on 971021-1130. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000266/19970191997-11-14014 November 1997 Insp Repts 50-266/97-19 & 50-301/97-19 on 970908-12.Noncited Violations Noted.Major Areas Inspected:Review of Licensee Licensed RO & SRO Requalification Training Programs IR 05000266/19970151997-10-14014 October 1997 Insp Repts 50-266/97-15 & 50-301/97-15 on 970707-11. Violations Noted.Major Areas Inspected:Fire Protection Program & Several App R Issues IR 05000266/19970181997-10-0404 October 1997 Insp Repts 50-266/97-18 & 50-301/97-18 on 970825-29. Violations Noted.Major Areas Inspected:Self Reading Dosimeter Calibrations,Radiation Work Permit Program, Condition Reporting Sys & Health Physics Organization ML20211B1961997-09-17017 September 1997 Insp Repts 50-266/97-17 & 50-301/97-17 on 970304-0805. Violations Noted.Major Areas Inspected:Operations & Maint IR 05000266/19970101997-09-15015 September 1997 Insp Repts 50-266/97-10 & 50-301/97-10 on 970519-0613. Violations Noted.Major Areas Inspected:Maint,Operations & Engineering Support IR 05000266/19970121997-08-14014 August 1997 Emergency Preparedness Insp Repts 50-266/97-12 & 50-301/97-12 on 970623-27.No Violations Noted.Major Areas Inpected:Ep Program ML20151K4271997-07-29029 July 1997 Insp Repts 50-266/97-14 & 50-301/97-14 on 970707-11. Violations Noted.Major Areas Inspected:Review of Radiological Environ Monitoring Program,Water Chemistry Control Program & Health Physics Insp ML20148L4451997-06-0909 June 1997 Insp Repts 50-266/97-08 & 50-301/97-08 on 970505-09. Violations Noted.Major Areas Inspected:Review of High Radiation Area Controls,Solid Radwaste Program, Transportation of Radwaste & Radiation Protection Program ML20138K2111997-05-0505 May 1997 Partially Withheld Insp Repts 50-266/97-07 & 50-301/97-07 on 970331-0410 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility & Security Performance IR 05000266/19970021997-04-25025 April 1997 Insp Repts 50-266/97-02 & 50-301/97-02 on 970113-0304.No Violations Noted.Major Areas Inspected:Preliminary Review of Portions of Operability Evaluation of CFCs & Tscr 192 IR 05000266/19970041997-04-0303 April 1997 Insp Repts 50-266/97-04 & 50-301/97-04 on 970303-07. Violations Noted.Major Areas Inspected:Review of High Radiation Area Controls,Liquid Effluent Program & Observation of Radiological Work & Review of SG Replacement IR 05000266/19970051997-04-0303 April 1997 Insp Repts 50-266/97-05 & 50-301/97-05 on 970208-0314.No Violations Noted.Major Areas Inspected:Insp to Review Use of Manual Operator Action in Place of Automatic Operation of Train a of MDAFW Sys During Accident 1999-09-30
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000266/19990151999-09-30030 September 1999 Insp Repts 50-266/99-15 & 50-301/99-15 on 990830-0903.No Violations Noted.Major Areas Inspected:Operations & Training IR 05000266/19990131999-09-29029 September 1999 Insp Repts 50-266/99-13 & 50-301/99-13 on 990714-0830.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000266/19990141999-08-31031 August 1999 Insp Repts 50-266/99-14 & 50-301/99-14 on 990726-30.No Violations Noted.Major Areas Inspected:Access Authorization Program,Alarm Stations & Communications.Security Mgt Also Inspected IR 05000266/19990091999-07-28028 July 1999 Insp Repts 50-266/99-09 & 50-301/99-09 on 990528-0713. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000266/19990121999-07-14014 July 1999 Insp Repts 50-266/99-12 & 50-301/99-12 on 990614-18.No Violations Noted.Major Areas Inspected:Implementation of Inservice Test Program & MOVs Capability,Per GL 96-05 IR 05000266/19990081999-06-18018 June 1999 Insp Repts 50-266/99-08 & 50-301/99-08 on 990411-0527.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19990061999-05-0707 May 1999 Insp Repts 50-266/99-06 & 50-301/99-06 on 990223-0410. Non-cited Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19990051999-04-20020 April 1999 Insp Repts 50-266/99-05 & 50-301/99-05 on 990222-0312. Violations Noted.Major Areas Inspected:Effectiveness & Engineering & Technical Support Organization in Performance of Routine & Reactive Site Activities & Problem Prevention IR 05000266/19990101999-04-19019 April 1999 Insp Repts 50-266/99-10 & 50-301/99-10 on 990329-0401.No Violations Noted.Major Areas Inspected:Review of Emergency Preparedness Program & Aspect of Plant Support IR 05000266/19990071999-03-16016 March 1999 Insp Repts 50-266/99-07 & 50-301/99-07 on 990216-19.No Violations Noted.Major Areas Inspected:Routine Insp of Radiation Protection & Chemistry Program Which Included Water Chemistry Control Program ML20204D8311999-03-12012 March 1999 Insp Rept 50-266/99-04 on 990105-0222.One Violations of NRC Requirements Occurred & Being Treated as non-cited Violation.Major Areas Inspected:Operations,Maint & Engineering IR 05000266/19990021999-03-10010 March 1999 Insp Repts 50-266/99-02 & 50-301/99-02 on 990105-0222. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000266/19990031999-02-0101 February 1999 Insp Repts 50-266/99-03 & 50-301/99-03 on 990111-15.No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Relating to Physical Protection of Facility IR 05000266/19980211999-01-15015 January 1999 Insp Repts 50-266/98-21 & 50-301/98-21 on 981121-990104. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19980221998-12-24024 December 1998 Insp Repts 50-266/98-22 & 50-301/98-22 on 981208-10.No Violations Noted.Major Areas Inspected:Maint Rule Program IR 05000206/19980191998-12-0404 December 1998 Insp Repts 50-206/98-19 & 50-301/98-19 on 981004.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000266/19980201998-11-30030 November 1998 Insp Rept 50-266/98-20 & 50-301/98-20 on 981102-06.No Violations Noted.Major Areas Inspected:Plant Biennial Exercise of Emergency Plan IR 05000266/19980171998-10-26026 October 1998 Insp Repts 50-266/98-17 & 50-301/98-17 on 980818-1005.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980181998-10-0202 October 1998 Insp Repts 50-266/98-18 & 50-301/98-18 on 980831-0904.No Violations Noted.Major Areas Inspected:Radiation Protection Program,Including Review of Whole Body Counter Calibration, Portable Instrument Calibration & Routine Contamination IR 05000266/19980151998-09-11011 September 1998 Insp Repts 50-266/98-15 & 50-301/98-15 on 980720-31.No Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training & Supporting Documentation to Ensure TS Required Surveillance Testing IR 05000266/19980131998-09-11011 September 1998 Insp Repts 50-266/98-13 & 50-301/98-13 on 980608-12 & 0715-16.Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training,Equipment & Supporting Documentation for Maint of Medium Voltage & Low Voltage IR 05000266/19980141998-09-0303 September 1998 Insp Repts 50-266/98-14 & 50-301/98-14 on 980707-0817.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980161998-08-10010 August 1998 Insp Repts 50-266/98-16 & 50-301/98-16 on 980713-17.No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility ML20236V6621998-07-29029 July 1998 Insp Repts 50-266/98-11 & 50-301/98-11 on 980526-0706. No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980091998-06-19019 June 1998 Insp Repts 50-266/98-09 & 50-301/98-09 on 980414-0523. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980121998-06-11011 June 1998 Insp Repts 50-266/98-12 & 50-301/98-12 on 980518-22. Violations Noted.Major Areas Inspected:Review of Unit 1 Refueling Outage Doses,Solid Radwaste Mgt,Transportation of Radioactive Matls & Health Physics Program IR 05000266/19980071998-06-0303 June 1998 Insp Rept 50-266/98-07 on 980310-13,16,17,0401-02,22,24 & 0504-05.No Violations Noted.Major Areas Inspected: Maint & Engineeing IR 05000301/19980051998-05-0505 May 1998 Insp Rept 50-301/98-05 on 971216-980309.Violations Noted. Major Areas Inspected:Maint ML20247D2961998-05-0505 May 1998 Insp Repts 50-266/98-06 & 50-301/98-06 on 980303-0413. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000266/19980081998-04-15015 April 1998 Insp Repts 50-266/98-08 & 50-301/98-08 on 980316-20.No Violations Noted.Major Areas Inspected:Radiation Protection Performance During Refueling Outage ML20217J4571998-04-0101 April 1998 Insp Repts 50-266/98-10 & 50-301/98-10 on 980310-18. Violations Noted.Major Areas Inspected:Review of Measuring & Test Equipment Procedures ML20217D3531998-03-21021 March 1998 Insp Repts 50-266/98-03 & 50-301/98-03 on 980120-0302. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19980041998-02-27027 February 1998 Insp Repts 50-266/98-04 & 50-301/98-04 on 980202-06.No Violations Noted.Major Areas Inspected:Review of Health Physics Dept Preparations for Unit 1 Refueling Outage, Including ALARA Planning & Work Planning ML20203D4361998-02-19019 February 1998 Insp Repts 50-266/97-23 & 50-301/97-23 on 971020-1107. Violations Noted.Major Areas Inspected:Licensee Controls in Area of SEs as Well as Effectiveness of Licensee Controls in Identifying,Resolving & Correcting Problems IR 05000266/19970221998-02-18018 February 1998 Insp Repts 50-266/97-22 & 50-301/97-22 on 971104-980203.No Violations Noted.Major Areas Inspected:Review of 20 Licensee Event Repts Submitted Between 960909 & 971215 ML20202E9811998-02-10010 February 1998 Insp Repts 50-266/97-26 & 50-301/97-26 on 971201-980120. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20202E3841998-02-0909 February 1998 Partially Withheld Insp Repts 50-266/98-02 & 50-301/98-02 on 980105-20 (Ref 10CFR73.71).Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility ML20199F1361997-12-22022 December 1997 Insp Repts 50-266/97-21 & 50-301/97-21 on 971021-1130. Violations Noted.Major Areas Inspected:Operations, Engineering,Maintenance & Plant Support IR 05000266/19970191997-11-14014 November 1997 Insp Repts 50-266/97-19 & 50-301/97-19 on 970908-12.Noncited Violations Noted.Major Areas Inspected:Review of Licensee Licensed RO & SRO Requalification Training Programs IR 05000266/19970151997-10-14014 October 1997 Insp Repts 50-266/97-15 & 50-301/97-15 on 970707-11. Violations Noted.Major Areas Inspected:Fire Protection Program & Several App R Issues IR 05000266/19970181997-10-0404 October 1997 Insp Repts 50-266/97-18 & 50-301/97-18 on 970825-29. Violations Noted.Major Areas Inspected:Self Reading Dosimeter Calibrations,Radiation Work Permit Program, Condition Reporting Sys & Health Physics Organization ML20211B1961997-09-17017 September 1997 Insp Repts 50-266/97-17 & 50-301/97-17 on 970304-0805. Violations Noted.Major Areas Inspected:Operations & Maint IR 05000266/19970101997-09-15015 September 1997 Insp Repts 50-266/97-10 & 50-301/97-10 on 970519-0613. Violations Noted.Major Areas Inspected:Maint,Operations & Engineering Support IR 05000266/19970121997-08-14014 August 1997 Emergency Preparedness Insp Repts 50-266/97-12 & 50-301/97-12 on 970623-27.No Violations Noted.Major Areas Inpected:Ep Program ML20151K4271997-07-29029 July 1997 Insp Repts 50-266/97-14 & 50-301/97-14 on 970707-11. Violations Noted.Major Areas Inspected:Review of Radiological Environ Monitoring Program,Water Chemistry Control Program & Health Physics Insp ML20148L4451997-06-0909 June 1997 Insp Repts 50-266/97-08 & 50-301/97-08 on 970505-09. Violations Noted.Major Areas Inspected:Review of High Radiation Area Controls,Solid Radwaste Program, Transportation of Radwaste & Radiation Protection Program ML20138K2111997-05-0505 May 1997 Partially Withheld Insp Repts 50-266/97-07 & 50-301/97-07 on 970331-0410 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility & Security Performance IR 05000266/19970021997-04-25025 April 1997 Insp Repts 50-266/97-02 & 50-301/97-02 on 970113-0304.No Violations Noted.Major Areas Inspected:Preliminary Review of Portions of Operability Evaluation of CFCs & Tscr 192 IR 05000266/19970041997-04-0303 April 1997 Insp Repts 50-266/97-04 & 50-301/97-04 on 970303-07. Violations Noted.Major Areas Inspected:Review of High Radiation Area Controls,Liquid Effluent Program & Observation of Radiological Work & Review of SG Replacement IR 05000266/19970051997-04-0303 April 1997 Insp Repts 50-266/97-05 & 50-301/97-05 on 970208-0314.No Violations Noted.Major Areas Inspected:Insp to Review Use of Manual Operator Action in Place of Automatic Operation of Train a of MDAFW Sys During Accident 1999-09-30
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000266/19990151999-09-30030 September 1999 Insp Repts 50-266/99-15 & 50-301/99-15 on 990830-0903.No Violations Noted.Major Areas Inspected:Operations & Training IR 05000266/19990131999-09-29029 September 1999 Insp Repts 50-266/99-13 & 50-301/99-13 on 990714-0830.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000266/19993011999-09-0808 September 1999 NRC Operator Licensing Exam Repts 50-266/99-301OL & 50-301/99-301OL (Including Graded Tests) for Tests Administered on 990726-0802 IR 05000266/19990141999-08-31031 August 1999 Insp Repts 50-266/99-14 & 50-301/99-14 on 990726-30.No Violations Noted.Major Areas Inspected:Access Authorization Program,Alarm Stations & Communications.Security Mgt Also Inspected IR 05000266/19990091999-07-28028 July 1999 Insp Repts 50-266/99-09 & 50-301/99-09 on 990528-0713. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000266/19990121999-07-14014 July 1999 Insp Repts 50-266/99-12 & 50-301/99-12 on 990614-18.No Violations Noted.Major Areas Inspected:Implementation of Inservice Test Program & MOVs Capability,Per GL 96-05 IR 05000266/19990081999-06-18018 June 1999 Insp Repts 50-266/99-08 & 50-301/99-08 on 990411-0527.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support PNO-III-99-027, on 990514,Unit 1 Was Manually Tripped Due to Steam Leak from 4B Feedwater Heater.Nrc Resident Inspectors Monitored Activities in CR Following Reactor Trip & Monitoring Progress of Repair Work.Licensee Notified NRC1999-05-19019 May 1999 PNO-III-99-027:on 990514,Unit 1 Was Manually Tripped Due to Steam Leak from 4B Feedwater Heater.Nrc Resident Inspectors Monitored Activities in CR Following Reactor Trip & Monitoring Progress of Repair Work.Licensee Notified NRC IR 05000266/19990061999-05-0707 May 1999 Insp Repts 50-266/99-06 & 50-301/99-06 on 990223-0410. Non-cited Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support ML20206E3331999-04-28028 April 1999 Notice of Violation from Insp on 990105-022.Violation Noted: Between 981222 & 990105,low Temp Condition with Potential to Cause Freezing of Common Min Flow Line Was Not Identified Nor Cause Determined IR 05000266/19990051999-04-20020 April 1999 Insp Repts 50-266/99-05 & 50-301/99-05 on 990222-0312. Violations Noted.Major Areas Inspected:Effectiveness & Engineering & Technical Support Organization in Performance of Routine & Reactive Site Activities & Problem Prevention IR 05000266/19990101999-04-19019 April 1999 Insp Repts 50-266/99-10 & 50-301/99-10 on 990329-0401.No Violations Noted.Major Areas Inspected:Review of Emergency Preparedness Program & Aspect of Plant Support IR 05000266/19990071999-03-16016 March 1999 Insp Repts 50-266/99-07 & 50-301/99-07 on 990216-19.No Violations Noted.Major Areas Inspected:Routine Insp of Radiation Protection & Chemistry Program Which Included Water Chemistry Control Program ML20204D8311999-03-12012 March 1999 Insp Rept 50-266/99-04 on 990105-0222.One Violations of NRC Requirements Occurred & Being Treated as non-cited Violation.Major Areas Inspected:Operations,Maint & Engineering ML20207L1211999-03-10010 March 1999 Notice of Violation from Insp on 990105-0222.Violation Noted:As of 990129,Operations Manual 3.7, AOP & EOP Sets Use & Adherence, Rev 5,major Procedure Prescribing Activities Affecting Quality,Inappropriate for Circumstance IR 05000266/19990021999-03-10010 March 1999 Insp Repts 50-266/99-02 & 50-301/99-02 on 990105-0222. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000266/19990031999-02-0101 February 1999 Insp Repts 50-266/99-03 & 50-301/99-03 on 990111-15.No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Relating to Physical Protection of Facility ML20199H5621999-01-15015 January 1999 Notice of Violation from Insp on 981121-990104.Violations Noted:As of 981015,adequate VT-2 Visual Exam of Pressure Retaining Boundary of Sfsp Common to Units 1 & 2 Not Performed During Each Code Insp Period IR 05000266/19980211999-01-15015 January 1999 Insp Repts 50-266/98-21 & 50-301/98-21 on 981121-990104. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000266/19980221998-12-24024 December 1998 Insp Repts 50-266/98-22 & 50-301/98-22 on 981208-10.No Violations Noted.Major Areas Inspected:Maint Rule Program IR 05000206/19980191998-12-0404 December 1998 Insp Repts 50-206/98-19 & 50-301/98-19 on 981004.No Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000266/19980201998-11-30030 November 1998 Insp Rept 50-266/98-20 & 50-301/98-20 on 981102-06.No Violations Noted.Major Areas Inspected:Plant Biennial Exercise of Emergency Plan IR 05000266/19980171998-10-26026 October 1998 Insp Repts 50-266/98-17 & 50-301/98-17 on 980818-1005.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980181998-10-0202 October 1998 Insp Repts 50-266/98-18 & 50-301/98-18 on 980831-0904.No Violations Noted.Major Areas Inspected:Radiation Protection Program,Including Review of Whole Body Counter Calibration, Portable Instrument Calibration & Routine Contamination IR 05000266/19980131998-09-11011 September 1998 Insp Repts 50-266/98-13 & 50-301/98-13 on 980608-12 & 0715-16.Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training,Equipment & Supporting Documentation for Maint of Medium Voltage & Low Voltage ML20151Y2571998-09-11011 September 1998 Notice of Violations from Insp on 980608-12 & 0715-16. Violations Noted:Licensee Failed to Determine Lowest Voltages Available at Breaker Close & Trip Coils Since Original Installation of Breaker IR 05000266/19980151998-09-11011 September 1998 Insp Repts 50-266/98-15 & 50-301/98-15 on 980720-31.No Violations Noted.Major Areas Inspected:Adequacy of Licensee Programs,Procedures,Training & Supporting Documentation to Ensure TS Required Surveillance Testing IR 05000266/19980141998-09-0303 September 1998 Insp Repts 50-266/98-14 & 50-301/98-14 on 980707-0817.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980161998-08-10010 August 1998 Insp Repts 50-266/98-16 & 50-301/98-16 on 980713-17.No Violations Noted.Major Areas Inspected:Review of Plant Support Activities Re Physical Protection of Facility IR 05000266/19983011998-07-29029 July 1998 NRC Operator Licensing Exam Repts 50-266/98-301 & 50-301/98-301 (Including Completed & Graded Tests) for Tests Administered on 980622-25.One SRO License Applicant Passed All Portions of Exam & Issued Operating License ML20236V6621998-07-29029 July 1998 Insp Repts 50-266/98-11 & 50-301/98-11 on 980526-0706. No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support ML20249C2851998-06-19019 June 1998 Notice of Violation from Insp on 980414-0523.Violation Noted:Licensee Did Not Test Some Refueling Sys Interlocks During Refueling Shutdowns from Time of Initial Plant Refueling Through 980422 IR 05000266/19980091998-06-19019 June 1998 Insp Repts 50-266/98-09 & 50-301/98-09 on 980414-0523. Violation Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000266/19980121998-06-11011 June 1998 Insp Repts 50-266/98-12 & 50-301/98-12 on 980518-22. Violations Noted.Major Areas Inspected:Review of Unit 1 Refueling Outage Doses,Solid Radwaste Mgt,Transportation of Radioactive Matls & Health Physics Program ML20249A0621998-06-11011 June 1998 Notice of Violation from Insp on 980518-22.Violation Noted: Two Emergency Plan SRDs Available for Use in Emergency Plan Sampling Kits,Not Calibrated in Dec 1997 IR 05000266/19980071998-06-0303 June 1998 Insp Rept 50-266/98-07 on 980310-13,16,17,0401-02,22,24 & 0504-05.No Violations Noted.Major Areas Inspected: Maint & Engineeing ML20247D6681998-05-0505 May 1998 Notice of Violation from Insp on 971216-980309.Violations Noted:Weld Procedure Wps GT-SM/1.1-1 Pb,Rev 4,used to Fabricate SG Replacement Main Steam & Feedwater Welds,Did Not Meet Requirements of QW-409.1 IR 05000301/19980051998-05-0505 May 1998 Insp Rept 50-301/98-05 on 971216-980309.Violations Noted. Major Areas Inspected:Maint ML20247D2961998-05-0505 May 1998 Insp Repts 50-266/98-06 & 50-301/98-06 on 980303-0413. Violations Noted.Major Areas Inspected:Licensee Operations, Engineering,Maint & Plant Support IR 05000266/19980081998-04-15015 April 1998 Insp Repts 50-266/98-08 & 50-301/98-08 on 980316-20.No Violations Noted.Major Areas Inspected:Radiation Protection Performance During Refueling Outage ML20217J4521998-04-0101 April 1998 Notice of Violation from Insp on 980310-18.Violation Noted: as of 980313,licensee Failed to Establish Measures to Assure That Conditions Adverse to Quality,Promptly Identified & Corrected ML20217J4571998-04-0101 April 1998 Insp Repts 50-266/98-10 & 50-301/98-10 on 980310-18. Violations Noted.Major Areas Inspected:Review of Measuring & Test Equipment Procedures ML20217D3451998-03-21021 March 1998 Notice of Violation from Insp on 980120-0302.Violation Noted:Replacement of 10CFR50,App B,Criterion V,State,In Part,That Activities Affecting Quality Shall Be Prescribed by Documented Instructions ML20217D3531998-03-21021 March 1998 Insp Repts 50-266/98-03 & 50-301/98-03 on 980120-0302. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support PNO-III-98-023, on 980305,unit 2 Completed TS-required Shutdown After Declaring CCW Sys Inoperable.While Shutdown, Licensee Plans to Conduct More Detailed Analysis of Postulated Failure1998-03-0606 March 1998 PNO-III-98-023:on 980305,unit 2 Completed TS-required Shutdown After Declaring CCW Sys Inoperable.While Shutdown, Licensee Plans to Conduct More Detailed Analysis of Postulated Failure IR 05000266/19980041998-02-27027 February 1998 Insp Repts 50-266/98-04 & 50-301/98-04 on 980202-06.No Violations Noted.Major Areas Inspected:Review of Health Physics Dept Preparations for Unit 1 Refueling Outage, Including ALARA Planning & Work Planning ML20203D4361998-02-19019 February 1998 Insp Repts 50-266/97-23 & 50-301/97-23 on 971020-1107. Violations Noted.Major Areas Inspected:Licensee Controls in Area of SEs as Well as Effectiveness of Licensee Controls in Identifying,Resolving & Correcting Problems IR 07100020/20110071998-02-19019 February 1998 Notice of Violation from Insp on 971020-1107.Violation Noted:Danger Tags 97-753 & 97-800 Were Installed on 971007 & 18,w/o Tag Sequence Numbers Being Assigned to Danger Tag Location Sheet IR 05000266/19970221998-02-18018 February 1998 Insp Repts 50-266/97-22 & 50-301/97-22 on 971104-980203.No Violations Noted.Major Areas Inspected:Review of 20 Licensee Event Repts Submitted Between 960909 & 971215 ML20202E9641998-02-10010 February 1998 NOV from Insp on 971201-980120.Violation Noted:From 980108- 09,operators Failed to Initiate Actions within 1 H to Place Unit in Hot Shutdown When Both Unit 1 safety-related 4,160- Volt Buses Were Powered from Standby Emergency Power Supply 1999-09-08
[Table view] |
See also: IR 05000266/1997008
Text
. _ . ._ . . - _ _ _ . _ _ _ . . _ _ _ . - - . - .
- . . _ . . . . _
-
_-
-
.
I
!
U.S. NUCLEAR REGULATORY COMMISSION
REGION lli
l
i
l Docket Nos: 50-266; 50 301
Licenses No: DPR-24; DPR-27
!
'
Reports No: 50 266/97008(DRS); 50-301/97008(DRS)
,
Licensee: Wisconsin Electric Power Company
Facility: Point Beach Nucisar Plant, Units 1 and 2
Location: 6610 Nuclear Road
Two Rivers, WI 54241
Dates: May 5-9,1997
Inspectors: R. Paul, Senior Radiation Specialist
K. Lambert, Radiation Specialist
i
Approved by: G. Shear, Chief, Plant Support Branch 2
Division of Reactor Safety
l
I
,
9706190249 970609 E
gDR ADOCK 05000266 I
ena g .
. .-
-
.
EXECUTIVE SUMMARY
Point Beach Nuclear Plant, Units 1 & 2 I
NRC Inspection Reports 50-266/97008; 50-301/97008
This announced inspection included a review of high radiation area controls, the solid
.
radwaste program, transportation of radwaste, and the radiation protection program. The l
following specific observations were made:
l
l
j * Continuing problems with high radiation area controls were identified as a contract i
painter entered several posted high radiation areas while on the Radiologically )
Controlled Area Entry Permit, which did not authorize entry into those areas. One
violation was identified (Section R1.1).
- The inspectors identified a violation in which, the licensee failed to provide
recurrent training for contractor health physics technicians assigned to radwaste in
-
accordance with Department of Transportation requirements (Section R8.1).
4
the radiologically controlled area, so that individuals pass by the health physics
station to inform a technician where they are going and the type of work to be l
performed. This has had a positive impact with ini eased communication between
1 workers and health physics (Section R2.1).
1
,
- The licensee effectively implemented the external dose program. ALARA reviews
were performed and identified radiological hot spots which could impact work being
performed. The licensee has good procedures in place to evaluate exposures from
hot particles (Section R1.2).
<
- The solid radwaste program was being implemented as described in the Process
] Control Program. The material condition of tanks and equipment in demineralizer
and processing radwaste tank cubicles was good (Section R1.3).
- * The continuing training program for the licensee's health physics technicians was
'
effectively implemented. However, the licensee identified, that contractor
technicians initial qualification cards were not completely signed-off and took
- corrective actions (Section R5.1).
,
- A comprehensive audit of the health physics program identified several areas with
minor deficiencies and provided recommendations for improvement. Corrective
actions in response to recommendations are being implemented (Section R7.1).
j
s
J
2 ,
i
- - .
I
i
-
.)
i
,
Report Details
i
R1 Radiological Protection and Chemistry (RP&C) Controls I
R1.1 Hiah Radiation Area Boundarv incident l
'
a. Inanection Scone (83750)
l
The inspectors reviewed and discussed with licensee personnel an incident where '
an individual entered a posted high radiation area (HRA) in the radiologically I
controlled area (RCA) of the primary auxiliary building (PAB) to perform painting J
functions without proper authorization.
1
b. Observation and Findinas
!
On April 8,1997, the licensee identified that a contract painter entered the Unit 1
Mixed Bed Domineralizer cubicle on April 7,1997, which was posted as a HRA-
RWP (radiation work permit) required. Upon further review the licensee identified I
that additional posted HRAs had also been entered by the contract painter. These ;
areas were Spent Fuel Pool Domineralizer cubicle, Unit 1 Reactor Coolant Filter I
cubicle: Unit 2 Reactor Coolant Filter cubicle, and Reactor Coolant Pump Seal Water i
Supply Filter cubicle. Of these areas, only the Spent Fuel Pool Domineralizer Filter
cubicle was an actual HRA with a dose rate of 150 mrom/hr at 30 centimeters (cm) I
from the locked door. The contract painter crew had access to the RCA through
the licensee's Radiologically Controlled Area Entry Permit (RCAEP), which does not
{
authorize entry into HRAs. The painters were not signed on to a specific RWP.
The contract painters possessed self reading dosimeters (SRDs) and
thermoluminescent dosimeters (TLDs), but did not possess a high range SRD or
electronic dosimeter as would be required for entry into HRA-RWP required areas.
Immediate corrective actions taken by the licensee were to temporarily suspend the
contract painters access to the RCA, send the painters TLDs for processing, and to
perform a root cause evaluation. The TLD results for the painter who entered the
HRAs were 30 mrem for the first quarter of 1997 and 20 mrem for the period April
1-8,1997. The painter's total dose of 50 mrem for 1997, was 20 mrem higher
than the nearest coworker's dose for the same periods.
Technical Specification (TS) 15.6.11 states, in part, that radiological control
procedures shall be written and made available to all station personnel. Health
Physics Manual Procedure HP 2.5.6, Revision 3, states that radiation workers are 1
responsible for complying with the requirements of the Radiologically Controlled i
Area Entry Permit (RCAEP). The RCAEP revised January 2,1997, states that
entering high radiation areas under this entry permit is an unauthorized work j
activity. Entry into an area posted as a high radiation area while on the RCAEP is a
violation of Technical Specification 15.6.11 (VIO 52-266/97008-01(DRS); 50-
301/97008-01(DRS)).
The licensee performed a common cause analysis to determine root causes of the !
continuing HRA boundary incidents. Preliminary results included the following root I
causes: (1) inadequate management expectations for worker performance; (2) lack 1
3 l
l
'
.. . - - . . - . . - . - . - - - - - - . , . - - . - .. . - - - - _..
i<-
.
,
j
of management support for the radiation protection program; (3) lack of
communication between health physics and the painters; (4) inadequate work
I oversight; and (5) lack of clear health physics procedures and policies. The 1
l licensee's immediate corrective actions to the common cause analysis were to )
, reconfigure the RCA access point so that individuals have to pass by a Health
Physics Technician (HPT) greater; require all newly trained radiation workers to
j attend an health physics orientation prior to unescorted access to the RCA, use of a
.
HPT rover by health physics, and issue a memo to all personnel from the plant !
-
manager on expectations for radiation workers. In addition, the licenses has '
{
retrained all contract painters in radiation worker practices prior to restoring their I
access to the RCA.
1
- c. Conclusions I
j
One violation was identified for entering a posted HRA while on the RCAEP. The
licensee performed a common cause analysis to determine root causes of the
continuing HRA boundary incidents. The licensee has implemented corrective i
I actions based on the preliminary results of the common cause analysis. I
'
- R1.2 External Dose Control and ALARA Imolementation
,
j a. Insoection Scone (83750)
!
i
'
The inspectors reviewed the licensee's program for controlling external dose to
~
workers. This included a review of individual dose records, the process for i
evaluating lost or off scale SRDs or lost TLDs, comparison of SRD and TLD results,
i
hot particle evaluations, and hot spot reduction programs.
.
b. Findinas
l
l The inspectors' review of selected individual dose records did not identify any i
- doses that exceeded licensee administrative limits. The licensee's total dose for the
! first quarter of 1997 was 31.1 person-rem, with a 1997 goal of 185 person-rem,
j The licensee has procedures in place to evaluate lost TLDs and SRDs. A review of
'
records revealed that the licensee has performed evaluations in accordance with
i procedures when dosimetry is lost. The licensee compared SRD and TLD doses in ,
accordance with procedures and performed evaluations when SRD/TLD ratios were
, outside the procedural limits. The licensee has good procedures in place to
- evaluate and document exposures from hot particles. The licensee performs
- - approximately 6 hot particle evaluations per year, with none performed recently.
The licensee files the evaluations in the employee's exposure file and does not
mairitain a log, therefore it is difficult for the licensee to retrieve the evaluations.
- Locations of hot spots are reviewed as part of the ALARA review for jobs.
Protective measures such as shielding or flushing of hot spots were performed to
reduce dose rates when there could be an impact on worker doses.
c. Conclusions
! The licensee effectively implemented the external dose program. ALARA reviews
i were performed and identified radiological hot spots which could impact work being
!
i 4
i
,.
- .- - . - . - . . _ ~ . . - . . - - . . - _ . - _ - - . _ _ - - . - ~ - . . . - - _ . -
_
-
- .
j performed. The licensee has good procedures in place to evaluate exposures from
j hot particles.
1
R1.3 Imalementation of the Solid Radioactive Waste Prooram
l a. Insoection Scone (86750)
! The inspectors reviewed the licensee's solid radioactive waste (radwaste) program
i as described in the USAR and the Process Control Program (PCP), and inspected
j demineralizer and processing radwaste tank cubicles.
j b. Observations and Findinas
j
j The licensee's radwaste included Dry Active Waste (DAW), evaporator
a
concentrates, spent resins, and process stream filters. Spent resins and filters were
i dewatered onsite, using a vendor system, and DAW was sent to an offsite
] contractor for processing. Waste not immediately sent for processing was stored in
-
the radwaste area or immediately outside the PAB truck bay in sea land vans,
- which were appropriately posted and secured. The 10 CFR Part 61 sampling and
i analysis program was conducted in accordance with the PCP and Radioactive
Materials Handling Manual, Procedures RDW 18.1.1 and 18.2. The inspectors
observed generally good housekeeping and appropriate posting and labeling in the
, radwaste storage and processing areas.
- The inspectors observed a spent resin transfer from a radwaste holding tank to the
radwaste shielded High Integrity Container (HIC), verified that the dewatering
l system was operated in accordance with procedural requirements, and that system l
l operators were knowledgeable about the system. During the transfer, an
! unexpected high alarm sounded and the transfer was automatically shutdown when
- the high level shutoff valve isolated the transfer. The reason for the high !
! water / resin level in the HIC was the inability of the radwaste dewatering pump to
j maintaln the same flow rate of the slurry pumped from the holding tank. No resin >
j or water was spilled because the shutoff valve operated as designed. The licensee
j wrote a condition report for this event to evaluate the adequacy of existing transfer
i procedures and to determine if they can safely transfer resin to the HIC while
!
controlling the slurry level in the HIC below the high level alarm setpoint. The
'
inspectors also noted during their pre-job briefing for the transfer evolution, that
specific contingencies concerning actions to be taken if significant problems arose
'
during the transfer were not discussed.
i
l The inspectors toured all radweste domineralizer and processing radweste tank
l- cubicles. The cubicles were accessible as the spent resins had been transferred to
!
a holding tank (controlled as HRA). The inspectors verified that the integrity and
i
material condition of the tanks were good and that there were no visible indications
- of resin leakage from the tanks. The licensee had recently initiated a program to
<
periodically inspect infrequently accessed cubicles and rooms to access system
j- integrity,
l
i
]
l
!
5
,
'
. - - . .,_ . . _ _
.
c. Conclusions
The inspectors concluded that the solid radwaste program was being implemented
as described in the PCP. The material condition of tanks and equipment in
demineralizer and processing radwaste tank cubicles was good.
R2 Status of RP&C Facilities and Equipment
R2.1 General Tours of Primarv Auxiliarv Buildina (83750)
The inspectors performed several inspections of activities in the PAB, including
several demineralizer cubicles (Discussed in Section R1.3 above), and observed
radiation worker practices. Radiological posting and boundaries in the PAB were
generally well maintained and housekeeping was good. Observed workers
demonstrated knowledge of radiological conditions. Personnel were wearing the
appropriate dosimetry.
The licensee reconfigured access to the RCA, so that individuals pass by the HP
station to inform a HPT greater where they are going and the type of work to be
performed. From discussion with workers and HPT greeters,it appeared that this
change has had a positive impact with increased communication between HP and
workers.
R5 Staff Training and Qualification in RP&C
R5.1 Technician Trainino
a. insoection Scone (83750)
The inspectors reviewed training programs for licensee technicians and contract
technicians. This included a review of training records, and discussions with
technicians.
b. Observations and Findinas
The licensee has not hired any HPTs for approximately 6 years. The licensee has a
program in place to provide continuing training to the HP staff. A review of training
records indicated that the continuing training program for licensee HPTs was
effectively implemented. However, the licensee identified, through a self
assessment, that contractor technicians initial qualification cards were not
completely signed-off. The licensee's review indicated that while the cards were
not signed-off, the technicians have performed the duties campetently. The
licensee intends to complete the qualification cards after the technicians adequately
perform the tasks in question. Until the sign-offs are complete, technicians will be
prohibited from independently performing those tasks not signed-off.
6
.
.
c. Conclusions
The technician training program was effectively implemented except for the
documentation of contractor qualification cards. This had been identified by the
licensee and corrective actions were implemented.
R7 Quality Assurance in RP&C activities
R7.1 Health Physics Denartment Audit
a. Insoection Scone (83750)
The inspectors attended an exit meeting where the preliminary results of an HP
department audit were presented. This was a comprehensive audit which included
a program review of radiation contamination monitoring, RWP control and
processing, waste disposal, dosimetry and ALARA, respiratory protection,
radiological environmental program, instrument calibration, and technical i
specification requirements. This audit was performed by a team comprised of
licensee personnel from the station and its headquarters, and individuals from
outside the licensee's organization. The audit team identified several areas where
improvements in the program could be made and initiated several condition reports.
The HP department manager indicated that corrective actions to the condition
reports and other areas will be implemented. The inspectors noted that the audit
appeared comprehensive and that corrective actions in response to
recommendations and condition reports should strengthen the HP program.
R8 Miscellaneous RP&C lasues
1
R8.1 Imolementation of Revised 49 CFR Parts 100-179 and 10 CFR Part 71 l
a. Insoection Scone (Tl 2515/133)
The inspectors reviewed the licensee's transportation program for the
implementation of the revised Department of Transportation (DOT) and NRC
trinsportation regulations for shipments of radioactive materials.
b. Observations and Findinas
The inspectors verified that station procedures correctly referenced the revised
Department of fransportation (DOT) requirements and, through interviews, that
workers responsible for shipping were cognizant of these requirements. Overall,
the .ecedures effectively incorporated the changes in the classification and
tra;.s . tation of LSA material and implemented the use of SI units as required in
49 CFR 172.203(d)(4). The inspectors reviewed selected 1996 and 1997
shipments and noted that documentation for several LSA material and SCO
shipments contained required information. The licensee used a vendor computer
program (RADMAN) to classify shipments and maintained current files of
certificates of compliance for high integrity containers (HICs), shipping cask
licenses, and burial site regulations.
7
.
The licensee's training program was comprehensive in content and effectively
addressed the regulations; personnel interviewed by the inspectors had an
acceptable understanding of the requirements. However, the inspectors identified
that current contractor technicians who are assigned to radwaste, and are
considered hazmat employees, had not been provided periodic training as required
by 49 CFR Part 172. The regulation requires all DOT defined hazmat employees to
receive recurrent training every three years. The last time contractor technicians
were trained at the station to meet these requirements was in 1991. Failure to
provide this training is a violation of 49 CFR 172.704(c)(2). (VIO 52-266/97008-
02(DRS); 50-301/97008-02(DRS)).
c. Conclusions
With the exception of the violation of DOT training requirements, the licensee's
transportation program was effective in meeting the revised DOT and NRC
transportation regulations for shipments of radioactive materials.
X1 Exit Meeting Summary
.
The inspectors presented the inspection results to members of licensee management at the
conclusion of the inspection on May 9,1997. The licensee acknowledged the findings
presented.
The licensee did not identify any information discussed as being proprietary.
8
. - . _ . . - - - . - . ~ . - - . . . . . . - ~ . - . - ~ - . . . _ - - . - _ _ - - - . - ..
b, .
,
'
'
PARTIAL LIST OF PERSONS CONTACTED
Licensee
A. J. Cayia, Plant Manager
E. J. Epstein, Health Physics Specialist
F. A. Flentje, Regulatory Specialist
' S. P. Johnson, Training Specialist
E. J. Lange, Health Physics Supervisor
T. A. Smith, Health Physics Supervisor
S. J. Thomas, Health Physics Specialist
P.' B. Tindall, Manager, Chemistry and Health Physics
INSPECTION PROCEDURES USED
IP 83750 Occupational Radiation Exposure
IP 86750 Solid Radioactive Waste Management and
Transportation of Radioactive Materials
IP 92904 Followup-Plant Support
Tl 2515/133 Implementation of Revised 49 CFR Parts 100-179
and 10 CFR part 71
LIST OF ITEMS OPENED AND CLOSED
Opened
50-266(301)/97008-01 VIO The failure to follow a Health Physics procedure and the
Radiologically Controlled Area Entry Permit is a violation
of Technical Specification 15.6.11
50 266(301)/97008-02 VIO The failure to provide hazmat training to contractor
HPTs working in redwaste once every three years is a
violation of 49 CFR 172.704(c)(2).
!
!
!
9
.. __- , . , _ _ _ . _ _ _ _ . _ _ _ __. _ __
. . - _ _. - _ . _ . . _ _ _ ______. __ - _ _ _ _
.
LIST OF DOCUMENTS REVIEWED
Condition Report No. 97-1132
Condition Report No. 97-1525
Condition Report No. 97-1540
Health Physics Implementing Procedure, HPIP 1.51, Revision 6, "SRD-TLD Comparison"
Health Physics implementing Procedure, HPIP 1.60, Revision 7, " Calculating Shallow and
Deep Dose Rates Due to Skin Contamination" l
Health Physics Implementing Procedure, HPIP 1.70, Revision 3, " Completion of Forms
NRC-4 and NRC-5"
Health Physics Manual, HP 2.15, Revision 3, " Control of Personnel Exposure to High Level
Contamination, Hot Particles, and Activated or Fission Product Debris"
Health Physics Manual, HP 2.15.1, Revision 3, " Implementation of Control Program for
High Level Contamination, Hot Particies, and Activated or Fission Product Debris" !
Health Physics Manual, HP 2.15.2, Revision 3, " Action Levels for Response to incidents
involving High Levels of Contamination, Hot Particles and Activated or Fission Product
Debris" l
Health Physics Manual, HP 2.5.6, Revision 3, " Radiologically Controlled Area Entry Permit" i
Health Physics Radiologically Controlled Area Orientation Checklist
Nuclear Procedures Manual, NP 4.2.19, Revision 1, " General Rules for Work in a
Radiologically Controlled Area"
Personnel Dosimetry Records
Process Control Program Manual
Radioactive Material Handling Manual, RDW 17.3, Revision 50, " Processing Bead Resin by
Dewatering"
Radioactive Material Handling Manual, RDW 18.1.1, Revision 1, "10 CFR 61 Sampling
Program"
Radioactive Material Handling Manual, RDW 18.2, Revision 1, "Radwaste Classification,
Shipment Type and Waste Stability Determination"
Radiologically Controlled Area Entry Permit, January 1 - December 31,1997
Technical Specification 15.6.11, " Radiation Protection Program"
Updated Safety Analysis Report, June 1992, Section 11, " Waste Disposal and Radiation
Protection System"
10