IR 05000409/2021001

From kanterella
Revision as of 08:26, 14 April 2022 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
NRC Inspection Report No. 05000409/2021-001 La Crosse Boiling Water Reactor
ML22005A144
Person / Time
Site: La Crosse File:Dairyland Power Cooperative icon.png
Issue date: 01/07/2022
From: Dave Hills
NRC/RGN-III/DNMS/FCB
To: Sauger J
EnergySolutions
Lee P
References
IR 2021001
Download: ML22005A144 (10)


Text

January 7, 2022

SUBJECT:

NRC INSPECTION REPORT NO. 05000409/2021001(DNMS) - LA CROSSE BOILING WATER REACTOR

Dear Mr. Sauger:

On December 15, 2021, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at the La Crosse Boiling Water Reactor (LACBWR) in Genoa, Wisconsin. The purpose of the inspection was to determine whether the decommissioning facility was maintained safely and in accordance with NRC requirements. The enclosed report presents the results of this inspection, which were discussed with Mr. S. Zoller of your staff on December 15, 2021.

The inspection consisted of an examination of activities at the facility as they relate to safety and compliance with the Commissions rules and regulations. Areas examined during the inspection included facility management and control, radiological safety, and confirmatory survey. Within these areas, the inspection consisted of a selective examination of procedures and representative records, field observations of activities in progress, and interviews with personnel.

Based on the results of this inspection, the NRC did not identify any violations.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations (CFR) 2.390, Public Inspections, Exemptions, Requests for Withholding. We will gladly discuss any questions you have concerning this inspection. If you have any questions, please contact Dr. Peter Lee of my staff at 630-829-9870.

Sincerely, Signed by Hills, David on 01/07/22 David E. Hills, Chief Materials Control, ISFSI, and Decommissioning Branch Division of Nuclear Materials Safety Docket No. 50-409 License No. DPR-45 Enclosure:

IR 05000409/2021001(DNMS)

cc w/encl: LaCrosseSolutions Service List