IR 05000305/1988005

From kanterella
Revision as of 19:58, 25 October 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Insp Rept 50-305/88-05 on 880216-23.Violation Noted.Major Areas Inspected:Review of Security Incident Involving Vital Area Barrier Degradation That Was Discovered on 880209 & Existed Since Const of Plant
ML20150E515
Person / Time
Site: Kewaunee Dominion icon.png
Issue date: 03/23/1988
From: Creed J, Kniceley J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20150E514 List:
References
50-305-88-05, 50-305-88-5, NUDOCS 8804010029
Download: ML20150E515 (1)


Text

. _ __- _ __

<

.

.

U.S. NUCLEAR REGULATORY COMMISSION

REGION III

Report No. 50-305/88005(DRSS)

Docket No. 50-305 License No. DPR-43 Safeguards Group IV Licensee: Wisconsin Public Service Corporation Post Office Box 1200 Green Bay, WI 54305 Facility Name: Kewaunee Nuclear Power Plant Inspection At: Kewaunee Site, Kewaunee, Wisconsin Inspection Conducted: February 16-17 (Onsite), and 18-23 (In-Office),1988 Type of Inspection: Special Announced Physical Security Inspection Inspector: M Ac~s F. R. Kniceley 4 3f>NM Date Physical Security Inspector Approved By: 9 Maa _ba% lo v 3l#fM James R. Creed, Chief 0 Date Safeguards Sectica Inspection Summary Inspection on February 16-23, 1938 (Report No. 50-305/87005(ORSS))

Areas Inspected: Included a review of a security incident involving a vital area (VA) barrier degradation that was discovered on February 9,1988, and has existed since construction of the plan Results: Based on this inspection, one violation was identified:

Physical Barriers - Vital Areas: The licensee failed to control access to a i vital area because of a degraded physical barrier which was not monitored, i (Section 3) l

l Enclosuro Contair SAFEGili.RM WTONt;T!Cl!

Upon Separation Tais Page is Decontrolled 8804010029 880325 PDR ADOCK 05000305 O DCD