1-TS Page (Issuance of Amd 140) Palo Verde Ngs, Units 1,2,&3. TS 5.6.5b, Core Operating Limits Report & Use of Zirlo Cladding Material
ML020710011
Person / Time
Site: Palo Verde  Arizona Public Service icon.png
Issue date: 03/12/2002
From: Donohew J
NRC/NRR/DLPM/LPD4
To: Overbeck G
Arizona Public Service Co
Shared Package
ML 003734091 List:
References
TAC MB3373, TAC MB3374, TAC MB3375
Download: ML020710011 (1)


Text

Reporting Requirements 5.6 5.6 Reporting Requirements (continued) 5.6.5 Core Operating Limits Report (COLR) (continued)

7. Letter: O.D. Parr (NRC) to F. M. Stern (CE). dated June 13, 1975 (NRC Staff Review of the Combustion Engineering ECCS Evaluation Model). NRC approval for:

5.6.5.b.6.

8. Letter: K. Kniel (NRC) to A. E. Scherer (CE). dated September 27, 1977 (Evaluation of Topical Reports CENPD-133. Supplement 3-P and CENPD-137, Supplement I-P). NRC approval for 5.6.5.b.6.
9. "Fuel Rod Maximum Allowable Pressure," CEN-372-P-A.

(Methodology for Specification 3.2.1, Linear Heat Rate).

10. Letter: A. C. Thadani (NRC) to A. E. Scherer (CE),

dated April 10, 1990, ("Acceptance for Reference CE Topical Report CEN-372-P"). NRC approval for 5.6.5.b.9.

11. -Arizona Public Service Company PWR Reactor Physics Methodology Using CASMO-4/SIMULATE-3," [Methodology for Specifications 3.1.1, Shutdown Margin - Reactor Trip Breakers Open: 3.1.2, Shutdown Margin - Reactor Trip Breakers Closed: 3.1.4. Moderator Temperature Coefficient; 3.1.7, Regulating CEA Insertion Limits and 3.9.1, Boron Concentration (Mode 6)].
12. "Technical Manual for the CENTS Code." CE-NPD 282-P-A.

Volumes 1-3. [Methodology for Specifications Shutdown Margin-Reactor Trip Breakers Closed: 3.1.2.

3.1.4, Moderator Temperature Coefficient: 3.1.5. CEA Alignment:

3.1.7. Regulating CEA Insertion Limits: 3.1.8. Part Length CEA Insertion Limits and 3.2.3. Azimuthal Power Tilt- Tq].

13. CENPD-404-P-A. 'Implementation of ZIRLOTh Cladding Material in CE Nuclear Power Fuel Assembly Designs.
c. The core operating limits shall be determined such that all applicable limits (e.g., fuel thermal mechanical limits.

Systems (ECCS) limits, nuclear limits such as SDM, transient analysis limits, and accident analysis limits) of the safety analysis are met.

d. The COLR. including any mid cycle revisions or supplements.

shall be provided upon issuance for each reload cycle to the NRC.

(continued)

PALO VERDE UNITS 2.2,3 5.6-5 AMENDMENT NO. .13- 140