March 6, 2002 MEMORANDUM TO: File FROM:
Jack N. Donohew, Senior Project Manager, Section 2 Project Directorate IV
/RA/
Division of Licensing Project Management Office of Nuclear Reactor Regulation
SUBJECT:
RESPONSES TO QUESTIONS ON LICENSE AMENDMENT REQUEST TO USE ZIRLO CLADDING FUEL FOR PALO VERDE UNITS 1, 2, AND 3 (TAC NOS. MB3373, MB3374, AND MB3375)
In its application of November 9, 2001, Arizona Public Service Company (the licensee),
submitted a request for a license amendment to the Technical Specifications (TSs) for Palo Verde Nuclear Generating Station, Units 1, 2 and 3. In the letter, the licensee proposed to add a topical report to Section 5.6.5.b of the TSs.
In the attached e-mail dated March 1, 2002, from the licensee, the license provided responses to questions to clarify the description of the proposed TS amendment in its application.
Docket Nos. STN 50-528, STN 50-529, and STN 50-530
Attachment:
E-mail Dated March 1, 2002
March 6, 2002 MEMORANDUM TO: File FROM:
Jack N. Donohew, Senior Project Manager, Section 2 Project Directorate IV
/RA/
Division of Licensing Project Management Office of Nuclear Reactor Regulation
SUBJECT:
RESPONSES TO QUESTIONS ON LICENSE AMENDMENT REQUEST TO USE ZIRLO CLADDING FUEL FOR PALO VERDE UNITS 1, 2, AND 3 (TAC NOS. MB3373, MB3374, AND MB3375)
In its application of November 9, 2001, Arizona Public Service Company (the licensee),
submitted a request for a license amendment to the Technical Specifications (TSs) for Palo Verde Nuclear Generating Station, Units 1, 2 and 3. In the letter, the licensee proposed to add a topical report to Section 5.6.5.b of the TSs.
In the attached e-mail dated March 1, 2002, from the licensee, the license provided responses to questions to clarify the description of the proposed TS amendment in its application.
Docket Nos. STN 50-528, STN 50-529, and STN 50-530
Attachment:
E-mail Dated March 1, 2002 DISTRIBUTION:
PUBLIC PDIV-2 R/F RidsOgcRp RidsAcrsAcnwMailCenter RidsNrrPMJDonohew (JDonohew)
RidsNrrLAMMcAllister (MMcAllister)
ACCESSION NO.: ML020630199 OFFICE PDIV-2/PM PDIV-1/LA PDIV-2/SC NAME JDonohew:as MMcAllister SDembek DATE 3/5/2002 3/5/02 3/5/02 OFFICIAL RECORD COPY
Attachment E-MAIL DATED MARCH 1, 2002 From:
"Weber, Thomas N(Z00499)" <TWEBER01@apsc.com>
To:
"'Jack Donohew'" <JND@nrc.gov>
Date:
3/1/02 10:20AM
Subject:
RE: A Question on A Past Amendment Issued 1.
The Zirlo Topical Report will be added to the COLR and will contain the complete identification including the report no., title, revision, date and any supplements. This will be done in accordance with the requirements of TS 5.6.5b of the PVNGS Technical specifications. Specifically, the note associated with TS 5.6.5b 2.
The complete listing of the Zirlo Topical Report into the PVNGS COLR will be completed in conjunction with the implementation of the TS Amendment approving the use of the Zirlo Topical Report.
If you have any questions or comments, please give me a call.
Original Message-----
From: Jack Donohew [1]
Sent: Friday, March 01, 2002 6:51 AM To: Weber, Thomas N(Z00499)
Subject:
RE: A Question on A Past Amendment Issued Thank you. I am going to add a reference to this amendment in the ZIRLO/COLR amendment to explain why the addition of that one topical report to TS 5.6.5.b does not have a revision number or date.
I, however, need to ask to two more questions on this ZIRLO/COLR amendment:
- 1. Would you confirm that the reference to this topical report that will be added to the COLR document (versus the COLR TS section) issued for each reload will have the topical report listed with the date and revision number given in reference 1 of the attachment to the 11/09/2001 application?
TSTF-363 states this complete citation should be done in the COLR document, and the staff's SE does not address this.
- 2. Will the listing of the topical report be added to the COLR document (versus the COLR TS section) during the implementation of the amendment?
<JND>
>>> "Weber, Thomas N(Z00499)" <TWEBER01@apsc.com> 02/28/02 07:09PM >>>
Jack, that was included as part of TS Amendment 137, issued along with the approval of the CENTS Code and other changes to the Administrative Section of TS's.
Original Message-----
From: Jack Donohew [2]
Sent: Thursday, February 28, 2002 12:45 PM To: Weber, Thomas N(Z00499)
Subject:
A Question on A Past Amendment Issued What amendments for the 3 units were issued to incorporate TSTF-363 in the TSs to allow topical report references listed in TS Section 5.6.5, "COLR,"
did not have to have the revision number and date, as long as the complete citation is given in the core operating limits report document? <JND>
CC:
"Proctor, James A(Z76277)" <JPROCTOR@apsc.com>, "Hasson, Craig A(V43830)" <CAHASSON@apsc.com>