ML022980530

From kanterella
Revision as of 04:59, 25 March 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Technical Specification Pages for Amendment No. 195, Technical Specification Change Selective Implementation of Alternative Radiological Source
ML022980530
Person / Time
Site: Robinson Duke Energy icon.png
Issue date: 10/04/2002
From:
NRC/NRR/DLPM/LPD2
To:
References
TAC MB4632
Download: ML022980530 (11)


Text

Containment Ventilation Isolation Instrumentation 3.3.6 Table 3.3.6-1 (page I of 1)

Containment Ventilation Isolation Instrumentation FUNCTION APPLICABLE REQUIRED SURVEILLANCE TRIP MODES OR OTHER CHANNELS REQUIREMENTS SETPOINT SPECIFIED CONDITIONS Manual Initiation 1.2.3.4.(a) 2 SR 3.3.6.6 NA 1.

2 trains SR 3.3.6.2 NA

2. Automatic Actuation Logic and Actuation Relays 1.2.3.4.(a) SR 3.3.6.3 SR 3.3.6.5
3. Containment Radiation Gaseous 1.2.3.4.(a) 1 SR 3.3.6.1 (b) a.

SR 3.3.6.4 SR 3.3.6.7

b. Particulate 1.2.3.4.(a) 1 SR 3.3.6.1 (b)

SR 3.3.6.4 SR 3.3.6.7

4. Safety Injection Refer to LCO 3.3.2. "ESFAS Instrumentation,' Functions l.a-f. for all initiation functions and requirements.

(a) During movement of recently irradiated fuel assemblies within the containment.

(b) Trip Setpoint shall be in accordance with the methodology in the Offsite Dose Calculation Manual.

HBRSEP Unit No. 2 3.3-39 Amendment No. 176,195

CREFS Actuation Instrumentation 3.3.7 3.3 INSTRUMENTATION 3.3.7 Control Room Emergency Filtration System (CREFS) Actuation Instrumentati on LCO 3.3.7 The CREFS actuation instrumentation for each Function in Table 3.3.7-1 shall be OPERABLE.

APPLICABILITY: MODES 1, 2. 3, 4 During movement of irradiated fuel assemblies I ACTIONS

..................................... NOTE .....................................

Separate Condition entry is allowed for each Function.

CONDITION REQUIRED ACTION COMPLETION TIME A. One automatic A.1 Place one CREFS train 7 days actuation train in emergency inoperable, pressurization mode.

B. Two automatic B.1 Place one CREFS train Immediately in emergency actuation trains pressurization mode.

inoperable.

OR One radiation monitoring channel inoperable.

_________ 1____________________ .7___________

(continued) 3.3-40 Amendment No. 176, 195 HBRSEP Unit No. 2

CREFS Actuation Instrumentation 3.3.7 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C. Required Action and C.1 Be in MODE 3. 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time for Condition A AND or B not met in MODE 1. 2, 3. or 4. C.2 Be in MODE 5. 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> D. Required Action and D.1 Suspend movement of Immediately associated Completion irradiated fuel Time for Condition A assemblies.

or B not met during movement of irradiated fuel assemblies.

SURVEILLANCE REQUIREMENTS

. . --.. NOTE... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Refer to Table 3.3.7-1 to determine which SRs apply for each CREFS Actuation Function.

SURVEILLANCE FREQUENCY SR 3.3.7.1 Perform CHANNEL CHECK. 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> SR 3.3.7.2 Perform COT. 92 days SR 3.3.7.3 Perform ACTUATION LOGIC TEST. 31 days on a STAGGERED TEST BASIS (continued) 3.3-41 Amendment No. 4;6,195 HBRSEP Unit No. 2

CREFS 3.7.9 3.7 PLANT SYSTEMS 3.7.9 Control Room Emergency Filtration System (CREFS)

LCO 3.7.9 Two CREFS trains shall be OPERABLE.

APPLICABILITY: MODES 1. 2, 3, and 4 During movement of iirradiated fuel assemblies. I ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. One CREFS train A.1 Restore CREFS train 7 days inoperable, to OPERABLE status.

B. Required Action and B.1 Be in MODE 3. 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time of Condition A AND not met in MODE 1, 2, 3, or 4. B.2 Be in MODE 5. 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> C. Required Action and C.1 Place OPERABLE CREFS Immediately associated Completion train in emergency Time of Condition A pressurization mode.

not met during movement of irradiated OR fuel assemblies.

C.2 Suspend movement of Immediately irradiated fuel assemblies.

(continued)

Amendment No. 1-;6. 195 HBRSEP Unit 2 3.7-22

CREFS 3.7.9 ACTIONS (continued)

D. Two CREFS trains D.1 Suspend movement of Immediately inoperable during irradiated fuel movement of irradiated assemblies.

fuel assemblies.

E. Two CREFS trains E.1 Restore at least one 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> inoperable in MODE 1. CREFS train to 2, 3, or 4. OPERABLE status.

F. Required Action and F.1 Be in MODE 3. 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time of Condition E AND not met in MODE 1, 2.

3, or 4. F.2 Be in MODE 5. 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.9.1 Operate each CREFS train for Ž 15 minutes. 31 days SR 3.7.9.2 Perform required CREFS filter testing in In accordance accordance with the Ventilation Filter with VFTP Testing Program (VFTP).

SR 3.7.9.3 Verify each CREFS train actuates on an 18 months actual or simulated actuation signal.

SR 3.7.9.4 Verify one CREFS train can maintain a 18 months on a positive pressure of 2 0.125 inches water STAGGERED TEST gauge, relative to the outside atmosphere BASIS and a positive pressure relative to adjacent building areas during the emergency pressurization mode of operation at a makeup flow rate of ; 400 cfm.

3.7-23 Amendment No. 1-76, 195 HBRSEP Unit 2

CREFS 3.7.9 Page is intentionally blank I 3.7-24 Amendment No. 4.-, 195 HBRSEP Unit 2

CREATC 3.7.10 3.7 PLANT SYSTEMS 3.7.10 Control Room Emergency Air Temperature Control (CREATC)

LCO 3.7.10 Two CREATC Water Cooled Condensing Unit (WCCU) trains shall be OPERABLE.

APPLICABILITY: MODES 1. 2, 3, and 4 During movement of i rradiated fuel assemblies. I ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. One CREATC WCCU train A.1 Restore CREATC WCCU 30 days inoperable, train to OPERABLE status.

B. Required Action and B.1 Be in MODE 3. 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time of Condition A AND not met in MODE 1. 2, 3, or 4. B.2 Be in MODE 5. 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> (continued) 3.7-25 Amendment No. 1-76,195 HBRSEP Unit No. 2

CREATC 3.7.10 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME C. Required Action and C.1 Place OPERABLE CREATC Immediately associated Completion WCCU train in Time of Condition A operation.

not met during movement of irradiated OR

.fuel assemblies.

C.2 Suspend movement of Immediately irradiated fuel assemblies.

D. Two CREATC WCCU trains D.1 Suspend movement of Immediately inoperable during irradiated fuel movement of irradiated assemblies.

fuel assemblies.

E. Two CREATC WCCU trains E.1 Restore at least one 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> inoperable in MODE 1, CREATC WCCU train to 2, 3, or 4. OPERABLE status.

F. Required Action and F.1 Be in MODE 3. 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time of Condition E AND not met in MODE 1. 2.

3, or 4. F.2 Be in MODE 5. 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> HBRSEP Unit No. 2 3.7-26 Amendment No. -1.76, 195

Containment Penetrations 3.9.3 3.9 REFUELING OPERATIONS 3.9.3 Containment Penetrations LCO 3.9.3 The containment penetrations shall be in the following status:

a. The equipment hatch closed and held in place by four bolts;
b. One door in the air lock closed; and
c. Each penetration providing direct access from the containment atmosphere to the outside atmosphere either:
1. closed by a manual or automatic isolation valve, blind flange, or equivalent, or
2. capable of being closed by an OPERABLE Containment Ventilation Isolation System.

APPLICABILITY: During movement of recently irradiated fuel assemblies within containment. I ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. One or more containment A.1 Suspend movement of Immediately penetrations not in recently irradiated required status. fuel assemblies within containment.

HBRSEP Unit No. 2 3.9-4 Amendment No. 1-7-6,195

Refueling Cavity Water Level 3.9.6 3.9 REFUELING OPERATIONS 3.9.6 Refueling Cavity Water Level LCO 3.9.6 Refueling cavity water level shall be maintained ; 23 ft above the top of reactor vessel flange.

APPLICABILITY: During movement of irradiated fuel assemblies within containment.

I ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Refueling cavity water A.1 Suspend movement of Immediately level not within irradiated fuel limit, assemblies within containment.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.9.6.1 Verify refueling cavity water level is 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />

23 ft above the top of reactor vessel flange.

HBRSEP Unit No. 2 3.9-10 Amendment No. 6, 195

Containment Purge Filter System 3.9.7 3.9 REFUELING OPERATIONS 3.9.7 Containment Purge Filter System LCO 3.9.7 The Containment Purge Filter System shall be OPERABLE and operating.

APPLICABILITY: During movement of recently irradiated fuel assemblies in I containment.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Containment Purge A.1 Close each Immediately Filter System penetration providing inoperable, direct access from the containment OR atmosphere to the outside atmosphere by Containment Purge a manual or automatic Filter System not in valve, blind flange.

operation. or equivalent method.

OR A.2 Suspend movement of Immediately recently irradiated fuel assemblies within containment.

HBRSEP Unit No. 2 3.9-11 Amendment No. ,76,195