SLS 2.0 2.0 SAFETY LIMITS (SLs) 2.1 SLS 2.1.1 Reactor Core SLs In MODES 1 and 2, the combination of THERMAL POWER, Reactor Coolant System (RCS) highest cold leg temperature, and pressurizer pressure shall not exceed the SLs specified in Figure 2.1.1-1.
2.1.2 RCS Pressure SL In MODES 1, 2, 3, 4, and 5, the RCS pressure shall be maintained
< 2735 psig.
2.2 SL Violations 2.2.1 If SL 2.1.1 is violated, restore compliance and be in MODE 3 within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.
2.2.2 If SL 2.1.2 is violated:
2.2.2.1 In MODE 1 or 2, restore compliance and be in MODE 3 within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.
2.2.2.2 In MODE 3, 4, or 5, restore compliance within 5 minutes.
HBRSEP Unit No. 2 2.0-l Amendment No. 176
SLS 2.0 I-t-G 560J ACCEPTABLE OPERATION 5
2 540-if2 520-HfQl.4 FLUX TRfP AT 118 OF RATED POWER sm-)
I I
0 I
20 I
40 I
I 60 I
80 100 120 NOTE: BASED ON A MINIMUM RCS FLOW OF 97.3 x lo6 lbm/hr Figure 2.1.1-l (page 1 of 1)