Special Report, Revision 1
ML090400574
Person / Time
Site: Catawba Duke Energy icon.png
Issue date: 02/04/2009
From: Morris J
Duke Energy Carolinas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML090400574 (5)


Text

Duke JAMES R. MORRIS, VICE PRESIDENT DEEnergy Duke Energy Carolinas, LLC Carolinas Catawba Nuclear Station 4800 Concord Road / CN01 VP York, SC 29745 803-701-4251 803-701-3221 fax February 4, 2009 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001

Subject:

Duke Energy Carolinas, LLC Catawba Nuclear Station, Unit 2 Docket No. 50-414 Special Report, Revision I Duke Energy is submitting a revision to the Special Report which had been sent on September 9, 200.8. The September 9, 2008 report was submitted pursuant to the requirements of Catawba Nuclear Station Selected Licensee Commitment (SLC) 16.7-15, Required Action "B. ." The report included the cause of the inoperability of the Unit 2 Channel A Hydrogen Monitor and plans for restoring the system to operable status.

This revision to the Special Report is being submitted due to the following:

1. Correct the incorrect statement that the hydrogen monitors are required to be operable during Mode 3.
2. Clarify the previous statement that the hydrogen monitors are required to mitigate the consequences of a Loss of Coolant Accident (LOCA).

The need for the revision noted above has been captured in the site Corrective Action Program. The revised Special Report is included as an attachment. There are no commitments contained in this letter. Any questions concerning this report may be directed to Marc Sawicki at (803) 701-5191.

Sincerely, J. R. Morris Attachment www. duke-energy corn

U.S. Nuclear Regulatory Commission February 4, 2009 Page 2 w/attachment xc: L. A. Reyes, Regional Administrator, Region II U. S. Nuclear Regulatory Commission Atlanta Federal Center 61 Forsyth St., SW, Suite 23T85 Atlanta, GA 30303 J. H. Thompson, NRR Project Manager U.S. Nuclear Regulatory Commission One White Flint North, Mail Stop 8 H4A 11555 Rockville Pike Rockville, MD 20852-2738 A.T. Sabisch, Senior Resident Inspector Catawba Nuclear Station

U.S. Nuclear Regulatory Commission February 4, 2009 Page 3 w/attachrnent bxc: NCMPA-1 NCEMC PMPA M.L. Edmunds CN03CE R. D. Hart CNO1RC B. G. Davenport ON02DB K. Ashe MGO1RC E. L. Black, III CN03CE M.J. Sawicki CNO1RC Electronic Licensing Library EC050 RGC File CNO1RC Master File CN-801.01 CN04DM

Reporting Requirement:

Catawba Nuclear Station Selected Licensee Commitment (SLC) 16.7-15, "Hydrogen Monitors," Required Action "A. I" requires that if one Hydrogen Monitor channel is inoperable, to restore that channel to operable status within 30 days. On August 26, 2008, it was determined that the 2A Hydrogen Monitor had been inoperable from January 5, 2008, until August 12, 2008, which exceeded the 30 day limit. Therefore Required Action "B. I" is entered which necessitated that if the Hydrogen Monitor channel cannot be restored as required in Required Action "A. 1", that a Special Report is to be prepared and submitted within 14 days to the Nuclear Regulatory Commission. The report shall outline the cause of the inoperability and the plans for restoring the channel to operable status. The report will be submitted within 14 days of the initial inoperability determination of the Hydrogen Monitor.

Description of the Event:

On January 5, 2008, the "READY" light was extinguished on the 2A Hydrogen Analyzer Control Unit. At that time a work request was written to repair the suspected problem; a failed light bulb. As there have been bulbs and lenses on these units needing replacement in the past, repair was not urgent.

On July 25, 2008, while performingthe 92 day calibration and 18 month calibration on Unit 2A Train Hydrogen Analyzer, the loss of indications and lights was observed on the Hydrogen Analyzer Control Unit, along with the trip of the sample pump. All lights illuminated during the calibration went dark with the exception of the "Standby" light, which always remained illuminated. Lights then extinguished unexpectedly three times during the calibration check and lasted approximately 1 to 2 minutes. A work request was written to address this problem. Subsequent investigation into this problem and review of the "READY" light issue from January 5, 2008 concluded that the 2A Hydrogen Analyzer had been in noncompliance with SLC 16.7-15 from January 5, 2008 until August 12, 2008.

The Containment Hydrogen Monitors (Hydrogen Analyzers) are used to monitor the concentration of hydrogen in containment after a severe accident involving core damage and confirm that random or deliberate ignition has occurred. These components are first used to determine if Hydrogen Igniters are effective, then used to determine if the Containment Hydrogen Sample and Purge System should be manually actuated. Two independent hydrogen monitors, while not used during normal plant operation, are required to be operable during Modes 1 and 2 to assure their post-LOCA availability.

The detection of hydrogen gas supports mitigative actions taken to maintain containment hydrogen concentration levels below explosive limits.

Cause of Inoperability:

Thermoswitch TC3 was opening and closing (cycling) because it was found to be operating around the same temperature to which the enclosure temperature Page 1 of 2

(Thermoswitch TC2) was operating. This cycling of TC3 correlated to the cycling of the extinguishing lights which had been observed on July 25, 2008. Furthermore, each time TC3 opened, the power to operate the Hydrogen Analyzer was lost such that the Hydrogen Analyzer would not have been able to perform its specified safety function if called upon during an accident.

The apparent cause of the inoperability is a lack of preventive maintenance, as the ihermoswitches have never been checked and have drifted from their original setpoints.

A history search did not reveal any problems in the past with any thermoswitches, leading one to assume that the thermoswitches have never been checked or adjusted.

Further, neither the preventative maintenance work.order nor the calibration procedure specifies to perform a calibration check of the thermoswitches.

Interim Actions:

The Hydrogen Analyzer was restored to operable status by August 12, 2008 by properly adjusting the setpoints for TC2 and TC3.

Individual Work Requests have been written to check and adjust, if necessary, the setpoints of TC2 and TC3 in all three other Hydrogen Analyzers at Catawba.

Planned Actions:

No Compensatory Actions are required as the Unit 2A Containment Hydrogen Monitor is operable. The site Corrective Action Program is tracking this issue. The following corrective actions are being taken to preclude reoccurrence:

1. Revision of the inspection procedure IP/1 &2/A/3176/001C to check the setpoints of TC2 and TC3.
2. 'Revise 18-month Preventive Maintenance Model Work Orders to check the setpoints of TC2 and TC3.
3. Request editorial modification to add additional guidance into vendor manual regarding the vendor's (Fenwal) thermoswitches.
4. Request OPS to review this event and determine how to better evaluate up-front failure modes and effects such that the proper focus is placed on work orders.
5. Add a statement to the Nuclear Assets Suite Program relating that failures of certain lights to illuminate may be caused by conditions rendering the Hydrogen Monitor inoperable.

Page 2 of 2