EN 56683 - Curtiss Wright, Interim Notification Report for PotentialPurt2l
ML23233A169
Person / Time
Site: Catawba  
Issue date: 08/17/2023
From: Franchuk T
Curtiss-Wright Corp
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
Download: ML23233A169 (1)


Text

CURTTSS-WRTGHT Nuclear Division 4600 East Tech Dr.. Cincinnati, OH 45245 Phone: 51 3.528.7900. Fax: 5'13.528.9292 www.CWNuclear.com August 11,2023 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555-000 1

Subject:

Interim Notification Report for PotentialPurt2l

Dear Sir or Madam:

This letter is being provided as an interim notification on a failure of a Curtiss Wright (CW) supplied Tyco (Agastat) safety related relay. The relay is identified as Agastat Part Number E7I02PELL004, Mfg serial number 16120301, CW tag # CJ583101, CW SAI02.

Duke Energy (Catawba Plant) notified CW on June 22, 2023 of the failure via letter. The Duke letter and background information is provided with this notification. Per Duke non-conformance details N.C. contacts 4 and 6 were found sticking in the open position. The contacts were cycled several times by Duke and eventually broke free. The relay was returned to CW for evaluation, however CW could not duplicate the failure.

As the relay is questionable for reliable service at this point CW is having the relay returned to Tyco for their evaluation. Once the evaluation is complete this report will be updated. CW anticipates an update to this notification with final results by October 15ft.

Sincerely:

f6+^-*lL Tim Franchuk Sr Director, Quality Assurance Curtiss-Wright Nuclear Division, 5t3-20t-2r76 TFranchuk@Curti ssWright. com Cincirurati Operations

DUKE ENERGY Catawba Nuclear Slation Duke Energy CNolVP I 4800 Concord Road York, SC 29745 RA-23-0158 June 20, 2023 Curtiss-Wright N uclear Division (Qualtech NP) 4600 East Tech Drive Cincinnati, Oh 45245 Attention: Tim Franchuk, QualityAssurance Direclor,tfranchuk@curtisswright.com

$ubject: Duke Energy Carolinas, LLC (Duke Energy)

Catawba Nuclear Station, Units 1 and 2 Request for Curtiss-Wright Determination of 10 CFR 21 Reportability Catawba Nuclear Condition Report (NCR) A2475101 RE:

Agastat Relay model E7000 Part number E701 2PELL004 The purpose of this letter is to formally notify Curtiss Wright of a discovery by Duke Energy concerning the above described relay. For your convenience the associated Nuclear Condition Report describing the as found condition is attached to this letter.

It is possible that 10 CFR 21 may require Curtiss Wright, as the supplier, to make a report to the NRC. Therefore, Duke Energy requests that Curtiss Wright review this issue against the reporting criteria of 10 CFR 21 and take appropriate action to assure that Curtiss Wright complies with 10 CFR 21 with respect to this issue, Duke Energy requests that Curtiss Wright replies to this letter indicating ownership of the evaluation process and provide documentation of its conclusions relative to 10 CFR 21 reportability for our records within 30 days of receipt of this letter. Please contact Josh Stewart of Catawba Engineering at (803)701-4277 or J9.shu-a.$e-wan@du&eetelgy.qom to arrange shipment of failed components if necessary.

Please direct any questions to Ari Tuckman of Catawba Regulatory Affairs at (803) 701-3771.

Sincerely,

'[nr*/X-E //"/"-

Mandy a. nar.U Nuclear Support Services Manager Catawba Nuclear Station

Le-tter from Duke Energy to Curtiss Wright RA-23-0158 Page 2 bxc:

M,B. Hare S.E. Andrews A. Linker J. Stewart A. Beekman