ML17263A981

From kanterella
Revision as of 17:16, 29 October 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards LER 95-001 Re Pressurizer Safety Valves Lift Settings Found Above TS Tolerance During post-svc Test,Due to Setpoint Shifts
ML17263A981
Person / Time
Site: Ginna Constellation icon.png
Issue date: 03/06/1995
From: Mecredy R
ROCHESTER GAS & ELECTRIC CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17263A982 List:
References
NUDOCS 9503160234
Download: ML17263A981 (2)


Text

P RI C) RIWY (ACCELERATED RIDS PROCESSING)

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9503160234 DOC.DATE: 95/03/06 NOTARIZED: NO DOCKET N FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G 05000244 AUTH. NAME AUTHOR AFFILIATION MECREDY,R.C. Rochester Gas & Electric Corp. F RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards LER 95-001 re pressurizer safety valves

.settings found above TS tolerance during post-svc test,due lift to setpoint shifts.

DISTRIBUTION CODE: IE22T COPIES RECEIVED:LTR TITLE: 50.73/50.9 Licensee Event Report (LER),&nciden Rpt, etc.

I ENCL SIZE'-

NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72). 05000244 F RECIPIENT COPIES'TTR RECIPIENT COPIES ID CODE/NAME ENCL ID CODE/NAME LTTR ENCL PD1-3 PD 1 1 JOHNSON,A 1 1 INTERNAL: AEOD/SPD/RAB 1 1 AEOD/SPD/RRAB 1 1

~FILE CEHTER+02 1 '

NRR/DE/ECGB 1 1 NRR/DE/EELB 1 1 NRR/DE/EMEB 1 1 NRR/DISP/PI PB 1 1 NRR/DOPS/OECB 1 1 NRR/DRCH/HHFB 1 1 NRR/DRCH/HICB 1 1 NRR/DRCH/HOLB 1 1 NRR/DRSS/PRPB 2 2 NRR/DSSA/SPLB 1 1 NRR/DSSA/SRXB 1 1 RES/DSIR/EIB 1 1 RGN1 FILE 01 1 . 1 EXTERNAL: L ST LOBBY HARD 1 1 LITCO BRYCE,J H 2 2 NOAC MURPHY,G.A 1 1 NOAC POORE,H. 1 1 NRC PDR 1 1 NUDOCS FULL TXT 1 1 LIMNI!

NOTE TO ALL"RIDS" RECIPIENTS:

DESK. ROOWI PI.37 (EVE 504-2083 ) TO E i PLEASE HELP US TO REDUCE O'ASTE! CONTACT THE DOC!:LIEST CONTROL ATE YOI.'R FAME F ROTI DISTRIBUTION LISTS I'OR DOCL'RIED'I'S YOL'Oi "I'L'ED!

FULL TEXT CONVERSION REQUIRED TOTAL NUMBER OF COPIES REQUIRED: 'LTTR 26 ENCL 26

1ND ROCHESTER GAS AND ElE'CTRIC CORPORATION ~ 89 FAST AtrENUE, ROCHESTER, N, Y Id6d9 0001 AREA CODE 716 $66.2700 ROBERT C. IrtECREDY Vice President Hucteor Operotions March 6, 1995 U.S. Nuclear Regulatory Commission Document Control Desk Attn: Allen R. Johnson PWR Project Directorate I-3 Washington, D.C. 20555

Subject:

LER 95-001, Pressurizer Safety Valves Lift Settings Found Above Technical Specifications Tolerance During Post-service Test, Due to Setpoint Shifts, Results in Independent Trains Being Considered Inoperable R.E. Ginna Nuclear Power Plant Docket No. 50-244 In accordance with 10 CFR 50.73, Licensee Event Report System, item (a) (2) (vii) (D), which requires a report of, "any event where a single cause or condition caused at least one independent train or channel to become inoperable in multiple systems or two independent trains or channels to become inoperable in a single system designed to ... mitigate the consequences of an accident", the. attached Licensee Event Report LER 95-001 is hereby submitted.

This event has in no way affected the public's health and safety.

Very truly yours, Robert C. Mecredy xc: U.S. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406 Ginna USNRC Senior Resident Inspector 9503i60234 950306 PDR ADOCK 05000244 S PDR