L-MT-08-028, Annual Radiological Environmental Operating Report

From kanterella
Revision as of 13:36, 12 July 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Annual Radiological Environmental Operating Report
ML081060237
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 04/11/2008
From: O'Connor T
Nuclear Management Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
FOIA/PA-2010-0209, L-MT-08-028
Download: ML081060237 (60)


Text

N omm mitred to NUCI Monticello Nuclear Generatinq Plant Operated by Nuclear Management Company, LLC April 11, 2008 L-MT-08-028 Technical Specification 5.6.1 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Monticello Nuclear Generating Plant Docket 50-263 License No. DPR-22 2007 Annual Radiological Environmental Operating Report In accordance with the Monticello Nuclear Generating Plant Technical Specification 5.6.1, the Nuclear Management Company, LLC is submitting the Annual Radiological Environmental Operating Report for the year 2007. This letter contains no new NRC commitments, nor does it modify any prior commitments.

Timothy J. O'Connor Site Vice President, Monticello Nuclear Generating Plant Nuclear Management Company, LLC Enclosure cc: Administrator, Region Ill, USNRC Project Manager, Monticello, USNRC Resident Inspector, Monticello, USNRC Minnesota Department of Commerce 2807 West County Road 75 Monticello, Minnesota 55362-9637 Telephone: 763-295-5151 Fax: 763-295-1454 ENCLOSURE I ANNUAL REPORT TO THE UNITED STATES NUCLEAR REGULATORY COMMISSION, RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM, JANUARY 1 TO DECEMBER 31,2007 58 pages follow

\ *.+.-....?..

,&sTz:=:L%.*, ... . ........ ..--: .<.&, ..... &,+7..,+":

.........

  • L%.;=:. em, ..... .......L* - ..*.. F*! Environmental, Inc. m: / Midwest Laboratorv

/ an Allegheny Tedlndogies Co. ' 700 Landwehr Road Northbrook, IL 60062-2310 ph. (847) 564-0700 fax (847) 564-4517 XCEL ENERGY CORPORATION MONTICELLO NUCLEAR GENERATING PLANT DOCKET NO. 50-263 LICENSE NO.

DPR-22 ANNUAL REPORT TO THE UNITED STATES NUCLEAR REGULATORY COMMISSION Radiological Environmental Monitoring Program January 1 to December 31, 2007 Prepared under Contract by ENVIRONMENTAL, Inc. Midwest Laboratory Project No. 801 0 Approved:

PREFACE The staff of Environmental, Inc., Midwest Laboratory was responsible for the acquisition of data presented in this report. Samples were collected by personnel of the Monticello Nuclear Generating Plant, operated by Nuclear Management Company, LLC for XCEL Energy Corporation.

This report was prepared by Environmental, Inc., Midwest Laboratory.

TABLE OF CONTENTS ...............................................................................................................................

Preface ii ...................................................................................................................... List of Tables iv ..................................................................................................................... List of Figures v INTRODUCTION

..........................................................................................................

1

SUMMARY

..........................................................................................................................

2 ...................... RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM (REMP) 3 3.1 Program Design and Data Interpretation

...............................................................

3 3.2 Program Description

..............................................................................................

4 .................................................................................................

3.3 Program Execution 5 3.4 Laboratory Procedures

..........................................................................................

6 3.5 Program Modifications

...........................................................................................

6 3.6 Land Use Census ..................................................................................................

6 ........................................................................................... RESULTS AND DISCUSSION 7 ....................................

4.1 Atmospheric Nuclear Detonations and Nuclear Accidents 7 4.2 Summary of Preoperational Data

..........................................................................

7 4.3 Program Findings ..................................................................................................

8 FIGURES AND TABLES

...................................................................................................

12 REFERENCES

..................................................................................................................

24 APPENDICES A Interlaboratory Comparison Program Results ....................................................................

A-1 B Data Reporting Conventions

.............................................................................................

B-I C Maximum Permissible Concentrations of Radioactivity in Air and Water Above Natural Background in Unrestricted Area

.............................................................

C-I ...................................................................................................

D Sampling Location Maps D.1 LIST OF TABLES No . - Title 5.1 Sample Collection and Analysis Program ......................................................................

13 5.2 Sampling Locations

........................................................................................................

14 5.3 Missed Collections and Analyses

................................................................................

16 ...............................................

5.4 Radiation Environmental Monitoring Program Summary 19 The following tables are in the Appendices: Appendix A A-1 Interlaboratory Comparison Program Results

...........................................................

Al-I A-2 Thermoluminescent dosimeters (TLDs) ......................................................................

A2-1 A-3 In-house Spiked Samples

...........................................................................................

A3-1 A-4 In-house "Blank" Samples ...........................................................................................

A4-1 A-5 In-house "Duplicate" Samples

................................................................................

A5-1 A-6 Department of Energy MAPEP comparison results

...................................................

A6-1 Attachment A: Acceptance criteria for spiked samples ....................................................

A2 Appendix C C-1 Maximum Permissible Concentrations of Radioactivity in air and water above background in unrestricted areas ........................................................................

C-2 LIST OF FIGURES No. - Title - Paae ..........................................

5-1 Offsite Ambient Radiation (TLDs), inner versus outer ring locations 17 5-2 Airborne Particulates; analysis for gross beta, average mean of all indicator locations versus control location

..............................................................................................

18 Appendix D D-I Sample collection and analysis program: TLD locations, Inner Ring ...............................................................................................................................

D-2 D-2 Sample collection and analysis program: TLD locations, Outer Ring .............................................................................................................................

D-3 D-3 Sample collection and analysis program: TLD locations, Controls ..............................................................................................................................

D-4 D-4 Sample collection and analysis program: Radiation Environmental Monitoring Program, ........................................................................................................... Milk sampling locations D-5 D-5 Sample collection and analysis program: Radiation Environmental Monitoring Program, Milk, Sludge, Ground water and Shoreline sampling locations

...............................................

D-6

1.0 INTRODUCTION

This report summarizes and interprets results of the Radiological Environmental Monitoring Program (REMP) conducted by Environmental, Inc., Midwest Laboratory for the Monticello Nuclear Generating Plant, Monticello, Minnesota, during the period January - December, 2007. This Program monitors the levels of radioactivity in the air, terrestrial, and aquatic environments in order to assess the impact of the Plant on its surroundings.

Tabulation of the individual analyses made during the year are not included in this report. These data are included in a reference document (Environmental, Inc., Midwest Laboratory, 2007a) available at the Monticello Nuclear Generating Plant, Chemistry and Radiation Protection Department. The Monticello Nuclear Generating Plant is a boiling water reactor with a nominal generating capacity of 620 MWe. It is located on the Mississippi River in Wright County, Minnesota, and operated by Nuclear Management Company, LLC. Initial criticality was achieved on December 10, 1970. Full power was achieved March 5, 1971 and commercial operation began on June 30, 1971.

2.0

SUMMARY

The Radiological Environmental Monitoring Program (REMP) required by the U.S. Nuclear Regulatory Commission (NRC) Technical Specifications and the Offsite Dose Calculation Manual (ODCM) for the Monticello Nuclear Generating Plant is described. Results for the year 2007 are summarized and discussed. Program findings show background levels of radioactivity in the environmental samples collected in the vicinity of the Monticello Nuclear Generating Plant.

No effect on the environment due to the operation of the Monticello Nuclear Generating Plant is indicated.

3.0 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM (REMP) Prosram Design and Data Interpretation The purpose of the Radiological Environmental Monitoring Program (REMP) at the Monticello Nuclear Generating Plant is to assess the impact of the Plant on its environment. For this purpose, samples are collected from the air, terrestrial, and aquatic environments and analyzed for radioactive content. In addition, ambient gamma radiation levels are monitored by thermoluminescent dosimeters (TLD's). Sources of environmental radiation include the following:

(1) Natural background radiation arising from cosmic rays and primordial radionuclides; (2) Fallout from atmospheric nuclear detonations; (3) Releases from nuclear power plants; (4) Industrial and medical radioactive waste; and (5) Fallout from nuclear accidents.

In interpreting the data, effects due to the Plant must be distinguished from those due to other sources. A major interpretive aid in assessment of these effects is the design of the monitoring program at the Monticello Plant which is based on the indicator-control concept. Most types of samples are collected both at indicator locations (nearby, downwind, or downstream) and at control locations (distant, upwind, or upstream).

A plant effect would be indicated if the radiation level at an indicator location was significantly larger than that at the control location. The difference would have to be greater than could be accounted for by typical fluctuations in radiation levels arising from other sources. An additional interpretive technique involves analyses for specific radionuclides present in environmental samples collected from the Plant site. The Plant's monitoring program includes analyses for tritium and iodine-131. Most samples are also analyzed for gamma-emitting isotopes with results for the following groups quantified: zirconium-95, cesium-1 37, cerium-144, beryllium-7, and potassium-40.

The first three gamma-emitting isotopes were selected as radiological impact indicators because of the different characteristic proportions in which they appear in the fission product mix produced by a nuclear reactor and that produced by a nuclear detonation.

Each of the three isotopes is produced in roughly equivalent amounts by a reactor: each constitutes about 10% of the total activity of fission products 10 days after reactor shutdown. On the other hand, 10 days after a nuclear explosion, the contributions of zirconium-95, cerium-144, and cesium-137 to the activity of the resulting debris are in the approximate ratio 4:1:0.03 (Eisenbud, 1963). Beryllium-7 is of cosmogenic origin and potassium-40 is a naturally-occurring isotope. They were chosen as calibration monitors and should not be considered as radiological impact indicators. The other group quantified consists of niobium-95, ruthenium-103 and

-106, cesium-1 34, barium-lanthanum-1 40, and cerium-1 41. These isotopes are released in small quantities by nuclear power plants, but to date their major source of injection into the general environment has been atmospheric nuclear testing. Nuclides of the final group, manganese-54, iron-59, cobalt-58 and -60, and zinc-65, are activation products and arise from activation of corrosion products. They are typical components of a nuclear power plant's effluents, but are not produced in significant quantities by nuclear detonations.

Program Design and Data Interpretation (continued)

Other means of distinguishing sources of environmental radiation are employed in interpreting the data. Current radiation levels are compared with previous levels, including those measured before the plant became operational. Results of the Plant's Monitoring Program can be related to those obtained in other parts of the world. Finally, results can be related to events known to cause elevated levels of radiation in the environment, e.g., atmospheric nuclear detonations.

3.2 Program Descri~tion The sampling and analysis schedule for the Radiological Environmental Monitoring Program (REMP) at the Monticello Plant is summarized in Table 5.1 and briefly reviewed below. Table 5.2 defines the sampling location codes used in Table 5.1 and specifies for each location its type (indicator or control) and its distance, direction, and sector relative to the plant site. To assure that sampling is carried out in a reproducible manner, detailed sampling procedures have been prescribed (Monticello Generating Plant REMP Surveillances, Current Revision). Maps of sampling locations are included in Appendix D. To monitor the air environment, airborne particulates are collected on membrane filters by continuous pumping at five locations.

Also, airborne iodine is collected by continuous pumping through charcoal filters at all of these locations. Filters are changed and counted weekly. Particulate filters are analyzed for gross beta activity and charcoal filters for iodine-1 31. Quarterly composites of particulate filters from each location are determined by gamma spectroscopy. One of the five locations is a control (M-I), and four are indicators (M-2, M-3, M-4, M-5). One of the indicators is located in the geographical sector expected to be most susceptible to any atmospheric emissions from the Plant (highest DIQ sector).

Ambient gamma radiation is monitored at forty locations, using CaS0,:Dy dosimeters with four sensitive areas at each location: fourteen in an inner ring in the general area of the site boundary, sixteen in the outer ring within 4-5 mile radius, six at special interest locations and four control locations, outside a 10 mile radius from the plant. They are replaced and measured quarterly. Milk samples are collected monthly from three farms (two indicator and one control). There are currently only two milk producers within the indicator area. Milk is collected biweekly during the growing season (May - October), because the animals may be on pasture. Samples are analyzed for iodine-131 and gamma-emitting isotopes. Leafy green vegetables (cabbage) are collected annually from the highest DIQ garden and a control location and analyzed for iodine-1

31. Corn and potatoes are collected annually only if the field is irrigated by water in which liquid radioactive effluent has been discharged. Analysis is for gamma-emitting isotopes.

Ground water is monitored by quarterly collections from three off-site locations (one control and two indicators) and one on-site Plant well. The samples are analyzed for tritium and gamma- emitting isotopes. Twelve on-site monitoring wells were added to the program and sampled for tritium and gamma isotopic analyses. Four of the wells (M-29 to M-32) are deep water drinking wells and were only sampled until the shallow monitoring wells (M-36 to M-40) could be completed The four deep drinking wells are no longer sampled as part of the analyses program River water is collected weekly at two locations, one upstream of the plant and one downstream. Monthly composites are analyzed for gamma-emitting isotopes. Quarterly composites are analyzed for tritium.

Procrram Description (continued)

Drinking water is collected weekly from the City of Minneapolis water supply, which is taken from the Mississippi River downstream of the Plant. Monthly composites are analyzed for gross beta, iodine-131, and gamma-emitting isotopes.

Quarterly composites are analyzed for tritium.

The aquatic environment is also monitored by semi-annual upstream and downstream collections of fish, invertebrates, and shoreline sediments. Shoreline sediment is also collected semi-annually from one downstream recreational location.

All samples are analyzed for gamma- emitting isotopes.

3.3 Proqram Execution The Program was executed as described in the preceding section with the following exceptions:

(1) Air Particulates I Air Iodine: No air particulate I air iodine samples were available from location M-4 for the week ending Sept.

5, 2007. There was no power to the substation.

Milk samples were not available from M-24 (Weinand Farm) for the November 14 and December 12 collection. The herd has been sold. Milk samples were not available from M-28 (Hoglund Farm) June 14th through October 25th, 2007. Dairy operations were temporarily discontinued.

Collections were resumed on Nov.

14,2007. (3) Thermoluminescent Dosimeters: The TLD for location M-1-08 was missing in the field for the second quarter, 2007. TLDs for location M-04C and Neutron Control B were missing in the third quarter, 2007. The TLDs for locations M-1-01 through M-1-13 and ISFSI-01 through ISFSI-10 neutron dosimeters were not installed for the third quarter, 2007, due to ISFSl construction. TLDs for location M-12A and ISFSI-14 neutron were missing in the fourth quarter, 2007. The TLDs for locations M-1-01 through M-1-10 and ISFSI-01 through ISFSI-10 neutron dosimeters were not installed for the fourth quarter, 2007, due to ISFSl construction.

(4) Invertebrates: The fall collection for invertebrates was missed due to river conditions. The water was too high to safely collect samples.

(5) Ground Water:

Plant Well #I 1 could not be sampled for the second quarter, 2007, due to site problems. A substitute sample was taken from Well

  1. 12. Deviations from the program are summarized in Table 5.3.

3.4 Laboratow Procedures The iodine-131 analyses in milk and drinking water were made using a sensitive radiochemical procedure which involves separation of the iodine using an ion-exchange method and solvent extraction and subsequent beta counting. Gamma-spectroscopic analyses are performed using high-purity germanium (HPGe) detectors. Levels of iodine-1 31 in cabbage and natural vegetation and concentrations of airborne iodine-1 31 in charcoal samples were determined by gamma spectroscopy. Tritium concentrations are determined by liquid scintillation.

Analytical Procedures used by Environmental, Inc. are on file and are available for inspection. Procedures are based on those prescribed by the Health and Safety Laboratory of the U.S. Dep't of Energy, Edition 28, 1997, U.S. Environmental Protection Agency for Measurement of Radioactivity in Drinking Water, 1980, and the U.S. Environmental Protection Agency, EERF, Radiochemical Procedures Manual. 1984.

Environmental, lnc., Midwest Laboratory has a comprehensive quality control/quality assurance program designed to assure the reliability of data obtained. Details of the QA Program are presented elsewhere (Environmental, Inc., Midwest Laboratory, 2003 ). The QA Program includes participation in lnterlaboratory Comparison (crosscheck) Programs. Results obtained in the crosscheck programs are presented in Appendix A.

3.5 Pronram Modifications Well Water, analysis for tritium and gamma-emitting isotopes.

Five onsite monitoring wells (M-36 through M-40) were added to the program in the fourth quarter of 2007. (Tables 5.1, 5.2). 3.6 Land Use Census In accordance with the MNGP Chemistry Manual, Procedure 1.05.41, "Annual Land Use Census and Critical Receptor Identification", a land use census shall be conducted and shall identify the location of the nearest milk animal, the nearest residence, and the nearest garden of greater than 500 ft2 producing fresh leafy vegetables, in each of the 16 meteorological sectors within a distance of 5 miles. The census shall also identify the locations of all milk animals and all 500 ft2 or greater gardens producing broad leaf vegetation in each of the meteorological sectors within a distance of three miles. This census shall be conducted at least once per year between the dates of May 1 and October

31. New locations shall be added to the radiation environmental monitoring program within 30 days and sampling locations having lower calculated doses or a lower dose commitment may be deleted from this monitoring program after October 31 of the year in which the land use census was conducted.

The 2007 land use census was conducted between September 10 and September 18,2007. There were no sectors in which the highest DIQ value increased by greater than 20%. No changes to the sampling procedures are required. In summary, the highest DIQ locations for nearest resident, garden and nearest milk animal did not change from the 2006 census.

Details of the land use census are contained in the Land Use Census and Critical Receptor Report, Monticello Nuclear Generating Plant, Chemistry and Radiation Protection Department.

4.0 RESULTS AND DISCUSSION All of the scheduled collections and analyses were made except those listed in Table 5.3. All results are summarized in Table 5.4 in a format recommended by the Nuclear Regulatory Commission in Regulatory Guide 4.8. For each type of analysis of each sampled medium, this table lists the mean and range for all indicator locations and for all control locations.

The locations with the highest mean and range are also shown. 4.1 Atmospheric Nuclear Detonations and Nuclear Accidents There were no reported accidents at nuclear facilities and no atmospheric nuclear tests conducted in the year 2007. The last reported test was made by the People's Republic of China on October 16, 1980. 4.2 Summaw of Preo~erational Data The following constitutes a summary of preoperational studies conducted at the Monticello Nuclear Generating Plant during the years 1968 to 1970, to determine background levels expected in the environment, and provided, where applicable, as a means for comparison with present day levels. Strict comparisons, however, are difficult to make, since background levels of radiation were much higher in these years due to ra$ioactive fallout from the atmosphere.

Gross 2 beta measurements in fallout averaged 20,600 pCiIm in 1969 and 12,000 pCi1m in 1970. These levels are reflected throughout the various media tested. In the air environment, ambient gamma radiation (TLDs) averaged 9.1 mRemI4 weeks during preoperational studies (1 970). Gross beta in air particulates in3 1969 and 1970 averaged 0.20 3 pCi1m . Present day levels have stabilized at around 0.025 pCiIm . Airborne radioiodine remained below detection levels. In the terrestrial environment of 1968 to 1970, milk, agricultural crops, and soil were monitored.

In milk samples, low levels of Cs-137 and Sr-90 were detected.

Cs-137 levels averaged 16.7 pCilL. Soybean crop measurements in 1969 averaged 35.5 pCilg for gross beta and 0.3 pCiIg for Cs- 137. Gross beta measured in soil averaged 51.7 pCilg . Present day measurements for cesium- 137 are below detection levels in milk and agricultural crops. The aqueous environment was monitored by testing of river water, bottom sediments, fish, aquatic vegetation, and periphyton. Specific location comparison of drinking, river, and well water concentrations for tritium and gross beta are not possible. However, tritium background levels, measured at seven separate locations from 1968 to 1970, averaged 970 pCiIL. Present day environmental samples measure below detection levels. Values for gross beta, measured from 1968 to 1970, averaged 9.8 pCilL in upstream and downstream Mississippi River water, 4.4 pCi/L for well waters, and 18.6 pCi/L for lake waters. Gamma emitters were below the lower limit of detection (LLD).

In shoreline sediments, gross beta background levels in 1970 averaged 49.8 pCiIg for both upstream and downstream samples. Cs-137 activity averaged 0.10 pCiIg for both upstream and downstream samples. Low levels of Cs-137, occasionally observed today can still be attributed to residual activity from atmospheric fallout. Gross beta levels in fish flesh averaged 5.3 pCilg in 1968 and 1969. Cs-137, measured in 1969 and 1970, averaged 0.044 pCilg. Gross beta background levels, in 1970, for aquatic vegetation, algae, and periphyton samples measured 86.7 pCiIg, 76.5 pCiIg, and 28.1 pCiIg respectively.

4.3 Proqram Findinns Results obtained show background levels of radioactivity in the environmental samples collected in the vicinity of the Monticello Nuclear Generating Plant. Ambient Radiation (TLD's) Ambient radiation was measured in the general area of the site boundary, at an outer ring 4 - 5 mi. distant from the Plant, at special interest areas and at four control locations. The means were similar for both inner and outer rings (16.1 and 15.1 mRem191 days, respectively). The mean for special interest locations was 14.7 mRem191 days and the mean for the control locations was 15.5 mRem191 days. Dose rates measured at the inner and outer ring locations were similar to those observed from 1992 through 2006 and are tabulated below. No plant effect on ambient gamma radiation is indicated (Figure 5-1). Ambient gamma radiation as measured by therrnolurninescent dosimetry.

Average quarterly dose rates, Inner vs. Outer Ring locations Airborne Particulates The average annual gross beta concentrations in airborn: particulates were almost identical at indicator and control locations (0.027 and 0.028 pCi/m , respectively) and similar to levels observed from 1992 through 2006. The results are tabulated below. Average annual gross beta concentrations in airborne particulates A spring peak in beta activity had been observed almost annually for many years (Wilson et a/., 1969). It had been attributed to fallout of nuclides from the stratosphere (Gold et a/., 1964). It was pronounced in 1981, occurred to a lesser degree in 1982, and has not occurred since 1983. The highest averages usually occur during the months of January and December, and the first and fourth quarters, as seen in 1992 through 2006. Gamma spectroscopic analysis of quarterly composites of air particulate filters yielded similar results for indicator and control locations. Beryllium-7, which is produced continuously in the upper atmosphere by cosmic radiation3(Arnold and Al-Salih, 1955) was detected in all samples, with an average activity of 0.077 pCi/m for all locations. All other gamma-emitting isotopes were below their respective LLD limits. Airborne iodine Weekly levels of airborne iodine-131 were below the lower limit of detection (LLD) of 0.03 pCi/m3 in all samples.

Milk - iodine-131 activity measured below the detection limit of 0.5 pCi1L in all samples.

No gamma-emitting isotopes, excepting naturally-occurring potassium-40, were detected. This is consistent with the finding of the National Center for Radiological Health (1968) that most radiocontaminants in feed do not find their way into milk due to the selective metabolism of the cow. Common exceptions are radioisotopes of potassium, cesium, strontium, barium, and iodine.

In summary, the milk data for 2007 show no radiological effects of the plant operation.

River Water and Drinkincl Water Tritium activity measured below the LLD of 500 pCi/L in all samples.

Gross beta activity in Minneapolis drinking water averaged 2.8 pCilL and was similar to average levels observed from 1992 through 2006.

Gross beta averages are tabulated below.

Average annual concentrations; Gross beta in drinking water. Year Comparisons with data reported by the USEPA for Minneapolis drinking water samples collected from 1980 through 2005 indicate that concentrations of these nuclides are remaining fairly constant. Gamma-emitting isotopes were below detection limits in all surface water samples. There was no indication of a plant effect.

Well Water Gross Beta (pCi1L) At the four indicator and control locations, tritium measured below the LLD level of 500 pCilL in all samples. Gamma isotopic results were below detection limits.

The data for 2007 were consistent with previous years results and no plant operational effects were indicated.

In three of the forty-nine monitoring well samples tested, tritium was detected at an average concentration of 591 pCilL. No gamma-emitting isotopes attributable to plant operation were detected.

I Year Gross Beta (pCilL)

Cabbage was collected in September from two locations and analyzed for iodine-131.

Levels of 1-131 measured below 0.034 pCi1g wet weight in both samples. Other gamma-emitting isotopes were below respective LLD levels. There was no indication of a plant effect.

There were no crops irrigated from the Mississippi River within 5 miles of the plant in 2007; therefore, no corn or potato samples were collected for analysis from irrigated fields.

Fish - Fish samples were collected in May and October. Flesh was separated from the bones and analyzed by gamma spectroscopy. Naturally-occurring potassium-40 was found to be similar in upstream and downstream samples (3.32 and 2.77 pCilg wet weight, respectively).

All gamma- emitting isotopes were below their respective LLD levels.

There was no indication of a plant effect. l nvertebrates Samples were collected in the third quarter of 2007, and analyzed for gamma-emitting isotopes. All gamma-emitting isotopes were below detection limits. There was no indication of a plant effect. Shoreline Sediments Upstream, downstream and downstream recreational area shoreline sediment collections were made in May and October and analyzed for gamma-emitting isotopes. Low levels of cesium-137 were detected in three of four downstream samples, averaging, 0.083 pCi/g dry weight, and 0.030 pCi1g dry weight in one of two control samples. Similar levels of activity and distribution have been observed since 1978, and are indicative of the influence of fallout deposition. The only other gamma-emitting isotopes detected were naturally-occurring beryllium-7 and potassium-40.

There was no indication of a plant effect.

5.0 FIGURES AND TABLES Table 5.1. Sample collection and analysis program, Monticello Nuclear Generating Plant. Collection Analysis Location Type and Type and Medium No. Codes (and Type)a ~requenc~~

FrequencyC Ambient radiation (TLDs) Airborne Particulates Airborne Iodine Milk Surface water Drinking water Well water On-site monitoring wells Edible cultivated crops - Come Leafy Vegetable Fish (one species, edible portion) Periphyton or invertebrates Shoreline sediment 3 M-10 (C), M-24, M-28 1 M-19 2 M-27, St. Cloud Farmer's Mkt. (C) 1 M-21 CIQ Ambient gamma CNV GB, GS (QC of each location)

CNV 1-131 GNV GS(MC), H-3(QC) GNV GB(MC), 1-1 31 (MC) GS (MC), H-3 (QC) GIQ H-3, GS GIA GS GIA 1-1 31 GIA GS 2 M-8(C), M-9 GISA GS 3 M-8(C), M-9, M-15 GlS A GS a Location codes are defined in Table 5.2. Control stations are indicated by (C). All other stations are indicators. Collection type is coded as follows: CI = continuous, GI = grab. Collection frequency is coded as follows:

W= weekly, M

= monthly, Q

= quarterly, SA

= semiannually, A

= annually. Analysis type is coded as follows:

GB = gross beta, GS = gamma spectroscopy, H-3

= tritium, 1-131 = iodine 131. Analysis frequency is coded as follows:

MC = monthly composite, QC = quarterly composite.

Milk is collected biweekly during the grazing season (May - October), if milch animals are on pasture. Collected only if the plant discharges radioactive effluent into the river, then only from river irrigated fields.

Table 5.2. Sampling locations, Monticello Nuclear Generating Plant. Distance and Direction from Code Typea Collection Site Sample ~ype~ Reactor C Air Station M-I Air Station M-2 Air Station M-3 Air Station M-4 Air Station M-5 C Upstream of Plant Intake Downstream of Plant Discharge C Campbell Farm City of Monticello Plant Well #I City of Minneapolis Montissippi Park River Irrigated Corn FieldC River lrrigated Potato FieldC Weinand Farm Wise residence (Highest DIQ Garden) a. Available Producer Hoglund Farm Warehouse

  1. 5 Receiving Warehouse Site Administration Building Shooting Range Monitoring Well #I Monitoring Well #2 Monitoring Well #3 Monitoring Well #4 Monitoring Well #5 Monitoring Well #6 Monitoring Well #7 Monitoring Well #8 AP, Al AP, Al AP, Al AP, Al AP, Al SW, SS, BO, F SW, SS, BO, F M, WW WW WW DW SS M VE, WW VE M WW WW WW WW WW WW WW WW WW WW WW WW 11.0 mi @ 307"INW 0.8 mi @ 14O0ISE 0.6 mi @ 104"IESE 0.8 mi @ 147"ISSE 2.6 mi @ 134"ISE < 1000' upstream

< 1000' downstream 10.6 mi @ 357"IN 3.3 mi @ 127"ISE 0.26 mi @ 252"ISW 37.0 mi @ 1 3Z01SE 1.27 mi @ 1 14"IESE 4.7 mi @ 18O0IS 0.64 mi @ 207"ISSW > 10.0 mi. 3.8 mi @ 30OoNVNW 276' @ 32"INNE 0.27 mi @ 156"ISSE 424' @ 192"ISSW 0.33 mi @ 1 1 1 "IESE 593' @ 299"NVNW 749' @ 301 "NVNW 770' @ 304"INW 0.1 mi @ 335"INNW 0.1 mi @ 253"NVSW 229' @ 228"ISW 0.2 mi @ 66"IENE 0.3 mi @ 15O0ISSE General Area of the Site Boundary M-OIA M-02A M-03A M-04A M-05A M-06A M-07A M-08A M-09A M-1 OA M-1 1A M-12A M-13A M-14A Sherburne Ave. So. Sherburne Ave. So.

Sherburne Ave. So. Biology Station Road Biology Station Road Biology Station Road County Road 75 County Road 75 County Road 75 County Road 75 County Road 75 County Road 75 North Boundary Road North Boundary Road TLD TL D TLD TLD TLD TLD TLD TLD TLD TLD TLD TLD TLD TLD Table 5.2. Sampling locations, Monticello Nuclear Generating Plant.

Distance and Direction from Code Typea Collection Site Sample ~~~e~ Reactor Approximately 4 to 5 miles Distant from the Plant M-OIB M-02B M-03B M-04B M-05B M-06B M-07B M-08B M-09B M-1 OB M-1 1B M-12B M-13B M-14B M-15B M-16B S~ecial Interest Locations Sherco #I Air Station TLD County Road 11 TLD County Road 73 & 81 TLD County Road 73 (196th St.) TLD City of Big Lake TLD County Road 14 and 196th St. TLD Monte Industrial Drive TLD Residence, Hwy 25 & Davidson Ave. TLD Weinand Farm TLD Reisewitz Farm, Acacia Ave. TLD Vanlith Farm, 97th Ave. TLD Lake Maria State Park TLD Bridgewater Station TLD Anderson Residence, Cty Rd. 11 1 TLD Red Oak Wild Bird Farm TLD Sand Plain Research Farm TLD Osowski Fun Market Krone Residence Big Oaks Park Pinewood School Rivercrest Christian Academy Monte Public Works C Kirchenbauer Farm C County Roads 4 and 15 C County Rd 19 and Jason Ave. C Maple Lake Water Tower TLD TLD TLD TLD TLD TLD TLD TLD TLD TLD - - a "C" denotes control location. All other locations are indicators. Sample Codes:

AP Airborne particulates Al Airborne Iodine BS Bottom (river) sediments BO Bottom organisms DW Drinking Water F Fish M Milk RW River Water SS Shoreline Sediments VE Vegetation I vegetables WW Well Water Collected only if the plant discharges radioactive effluent into the river, then only from river irrigated fields.

Table 5.3. Missed coilections and analyses at the Monticello Nuclear Generating Plant. All required samples were collected and analyzed as scheduled with the following exceptions:

Sample Type APIA1 MI MI TLD BO TLD TLD Analysis Beta, 1-131 Gamma, 1-131 Gamma, 1-1 31 Ambient Gamma Gamma Ambient Gamma Neutron Dosimetry Ambient Gamma Neutron Dosimetry Location M-04 M-28 M-24 M-1-08 M-08 M-09 M-04C M-1-01 to M-1-13 Control B ISFSI-01 to ISFSI-10 M-12A M-1-01 to M-1-10 ISFSI-14 ISFSI-01 to ISFSI-10 Collection Date or Period 91512007 611412007 through 1 0125/2007 11/14/2007 1211 212007 2nd. Qtr. 2007 3rd. Qtr. 2007 3rd. Qtr. 2007 3rd. Qtr.

2007 4th. Qtr. 2007 4th. Qtr. 2007 Reason for not conducting REMP as required No power to substation. Hoglund Dairy temporarily out of business for the summer.

Weinand Farm no longer in the dairy business.

Missing in the field Missed collection due to unsafe river conditions.

Missing in the field Not installed due to ISFSl construction.

Missing in the field Not installed due to ISFSl construction.

Missing in the field Not installed due to ISFSl construction.

Missing in the field Not installed due to ISFSl construction.

Plans for Preventing Recurrence None required.

Hoglund will inform the MNGP upon resumption of operation.

Operation resumed 1 111 4/07. None required. None required. None required. None required. None required.

Figure 5-1. Offsite Ambient Radiation (TLDs); lnner Ring versus Outer Ring locations.

1 1 - - Inner Ring 1 Figure 5-2. Airborne Particulates; analysis for gross beta, average mean of all indicator locations versus control location. - r - Indicators (M-2, 3,4, 5) - Control (M-I ) Nr9bmcot-comOrN~~~~~

mmmmmmmmoooooooo ZZZZ?Z?ZZ8ZEZZZZ Table 5.4 Radiological Environmental Monitoring Program Summary Name of Facility Monticello Nuclear Generating Plant Docket No.

50-263 Location of Facility Wright, Minnesota Reporting Period January-December, 2007 ( County, State ) Sample Type (Units) TLD (Inner R~ng, General Area at Site Boundary) mReml91 days) TLD (Outer Ring, 4-5 mi. distant) mReml91 days) TLD (Special Interest Areas) mReml91 days) TLD (Control) mReml91 days) Airborne Particulates (p~ilrn~) Airborne Iodine (pci1m3) Type and Number of Analysesa Gamma 55 Gamma 64 Gamma 24 Gamma 15 GB 259 GS 20 Be-7 Mn-54 CO-58 Co-60 Zn-65 Zr-Nb-95 Ru-103 Ru-106 CS-134 CS-137 Ba-La-140 Ce-141 Ce-144 1-131 259 LLD~ 3.0 3.0 3.0 3.0 0.005 0.015 0.0009 0.0008 0.001 1 0.0014 0.0013 0.0013 0.0063 0.0009 0.0007 0.0047 0.0024 0.0043 0.03 Indicator Locations Mean (F)' RangeC 16.1 (55155) ( 12.6-20.1) 15.1 (64164) ( 12.6-18.9) 14.7 (24124) ( 10.7-18.0)

None 0.027 (2071207)

(0.010-0.084) 0.076 (16116) (0.045-0.101)

< LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD Location with Annual ~ocation" M-11A 0.4 mi @ 25O0NVSW M-079 4.4 mi @ 135"ISE M-06S, Mont. Pub. Wks.

2.7 mi @ 136"ISE M-03C, County Rd.19

& Jason, 11.6 mi. @ 13Oo1SE M-I (C) 11.0 mi @ 307"INW M-5, Air Stat~on 2.6 mi @ 134"ISE Control Locations Mean (F)' RangeC (See Control below.) (See Control below.) (See Control below.) 15.5 (15115) ( 13.7-17.9) 0.028 (52152) (0.010-0.083) 0.078 (414) (0.065-0.093)

< LLD < LLD 4 LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD Highest Mean Mean (F)' RangeC 18.1 (4 14) (15.6-20.1) 16.5 (4 14) (1 5.2-18.3) 16.8 (4 14) (1 5.9-18.0) 16.7 (414) (14.9-17.7) 0.028 (52 152) (0.010-0.083) 0.087 (414) (0.058-0.101)

Number Non- Routine Resultse 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Table 5.4 Radiological Environmental Monitoring Program Summary Name of Facility Monticello Nuclear Generating Plant Docket No.

50-263 Location of Facility Wright, Minnesota Reporting Period January-December, 2007 ( County, State ) Sample Type (Units) Milk (pCilL) R~ver Water (pCilL) Type and Number of Analysesa 1-131 45 GS 45 K-40 CS-134 CS-137 Ba-La-140 H-3 8 GS 24 Mn-54 Fe-59 CO-58 CO-60 Zn-65 Zr-Nb-95 CS-1 34 CS-137 Ba-La-140 Ce-144 LLDb 0.5 200 5 5 5 500 10 30 10 10 30 15 10 10 15 45 Indicator Locations Mean (F)' RangeC < LLD 1339 (26126) (1 190-1445)

< LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD Control Locations Mean (F)' RangeC < LLD 1389 (19119) (1313-1513)

< LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD Number Non- Routine Resultse 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Location with Highest Annual Mean

~ocation~

M-28 Hoglund Farm Mean (F)' Rangec 1394 (9 19) (1279-1445)

Table 5.4 Radiological Environmental Monitoring Program Summary Name of Facility Monticello Nuclear Generating Plant Docket No.

50-263 Location of Facility Wright, Minnesota Reporting Period January-December, 2007 ( County, State ) Sample Type (Units) Drinking Water (pCilL) Well Water (pCilL) Crops - Cabbage (pcilgwet)

Type and Number of Analysesa GB 12 1-131 12 H-3 4 GS 12 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 Ce-144 H-3 65 GS 65 Mn-54 Fe-59 CO-58 Co-60 Zn-65 Zr-Nb-95 CS-1 34 CS-137 Ba-La-140 Ce-144 GS 2 1-131 CS-1 34 CS-137 LLD~ 1.0 1.0 500 10 30 10 10 30 15 10 10 15 38 500 10 30 10 10 30 15 10 10 15 54 0.034 0.020 0.028 Indicator Locations Mean (F)' RangeC 2.8 (12112) (1.7-4.8)

< LLD < LLD < LLD < LLD < LLD < LLD < LLD LLD < LLD < LLD < LLD < LLD 591(3165)

(505-732)

< LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD Locat~on with Annual ~ocat~on~

M-14, Minneapolis 37.0 mi. @ 132" ISE Monitoring Well #3 770' @304" INW Control Locations Mean (F)' RangeC None None None None None None None None None None None None None < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD Highest Mean Mean (F)' ~ange' 2.8 (12112) (1.7-4.8) 634 (216) (535-732)

Number Non- Routine Resultse 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Table 5.4 Radiological Environmental Monitoring Program Summary Name of Facility Monticello Nuclear Generating Plant Docket No. 50-263 Location of Facility Wright, Minnesota Reporting Period January-December, 2007 ( County, State ) Sample Type (Units) Fish (pCilg wet) Invertebrates (pCilg wet) Type and Number of Analysesa GS 4 K-40 Mn-54 Fe-59 CO-58 Co-60 Zn-65 Zr-Nb-95 CS-134 CS-137 Ba-La-140 Ce-144 GS 2 Be-7 K-40 Mn-54 Fe-59 CO-58 Co-60 Zn-65 Zr-Nb-95 Ru-1 03 Ru-1 06 CS-134 CS-137 Ba-La-140 Ce-144 LLD~ 0.10 0.015 0.031 0.017 0.014 0.033 0.024 0.013 0.016 0.087 0.10 0.76 1.14 0.063 0.11 0.084 0.062 0.13 0.1 1 0.11 0.53 0.046 0.047 0.68 0.34 Indicator Locations Mean (F)' RangeC 2.77 (212) (2.51-3.03) 4 LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD c LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD Location with Highest Control Locations Mean (F)' RangeC 3.32 (212)

(3.21-3.42)

< LLD < LLD < LLD c LLD c LLD < LLD < LLD < LLD < LLD < LLD < LLD c LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD < LLD Annual ~ocation~ M-08, Upstream

< 1000' of discharge Number Non- Routine Resultse 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Mean Mean (F)' RangeC 3.32 (212) (3.21-3.42)

Table 5.4 Radiological Environmental Monitoring Program Summary Name of Facility Monticello Nuclear Generating Plant Docket No. 50-263 Location of Facility Wright, Minnesota Reporting Period January-December, 2007 ( County, State ) a GB = gross beta, GS = gamma scan.

LLD = nominal lower limit of detection based on a 4.66 sigma counting error for background sample.

Mean and range are based on detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parentheses (F). Locations are specified: (1) by name, andlor station code (Table 2) and (2) by distance (miles) and direction relative to reactor site. Non-routine results are those which exceed ten times the control station value. If no control station value is available, the result is considered non-routine if it exceeds ten time the typical preoperational value for the medium or location.

Sample Type (Units) Shoreline Sediments (pCi19 dry) Type and Number of Analysesa GS 6 Be-7 K-40 Mn-54 Fe-59 CO-58 Co-60 Zn-65 Nb-95 Zr-95 Ru-103 Ru-106 CS-134 Cs-1 37 Ba-La-140 Ce-I 44 LLD~ 0.19 0.10 0.020 0.070 0.021 0.014 0.045 0.028 0.037 0.026 0.16 0.016 0.01 6 0.062 0.10 Indicator Locations Mean (F)' ~ange' 0.42 (114) 10.80 (414) (9.86-1 1.79) < LLD c LLD < LLD c LLD < LLD < LLD < LLD c LLD < LLD < LLD 0.083 (314) (0.043-0.120) c LLD < LLD Control Locations Mean (F)' RangeC c LLD 10.85 (212) (9.67-12.03) c LLD c LLD < LLD c LLD < LLD c LLD c LLD < LLD < LLD < LLD 0.030 (112) c LLD < LLD Number Non- Routine Resultse 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Location with Highest Annual ~ocation~

M-15, Montissippi Park 1.27 mi @ 114"lESE M-08, Upstream < 1000' of discharge M-09, Downstream

< 1000' of discharge Mean Mean (F)' ~ange' 0.42 (112) 10.85 (212) (9.67-12.03) 0.120 (112)

6.0 REFERENCES

CITED Arnold, J. R. and H. A. Al-Salih. 1955.

Beryllium-7 Produced by Cosmic Rays. Science 121:

451-453. Eisenbud, M. 1963. Environmental Radioactivity, McGraw-Hill, New York, New York, pp. 213, 275, 276.

Environmental, Inc., Midwest Laboratory.

2001a through 2008a. Radiation Environmental Monitoring for Monticello Nuclear Generating Plant, Complete Analysis Data Tables, January-December, 2000 through 2007. 2001b through 2008b. Radiation Environmental Monitoring for Prairie Island Nuclear Generating Plant, Complete Analysis Data Tables, January - December, 2000 through 2007. 2003. Quality Assurance Program Manual, Rev.

1, 01 October 2003. 2005. Quality Control Procedures Manual, Rev. 0, 17 September 2005. 2003. Quality Control Program, Rev.

1, 21 August 2003. Gold, S., H.W. Barkhau, B. Shlein, and B. Kahn, 1964.

Measurement of Naturally Occurring Radionuclides in Air, in the Natural Environment, University of Chicago Press, Illinois, 369-382. Hazleton Environmental Sciences Corporation.

1979a through 1983a. Radiation Environmental Monitoring for Monticello Nuclear Generating Plant, Complete Analysis Data Tables, January - December 1978 through 1982.

1979b through 1983b. Radiation Environmental Monitoring for Prairie Island Nuclear Generating Plant, Complete Analysis Data Tables, January - December 1978 through 1982.

Hohenemser, C. M. Deicher, A. Emst, H. Hofsass, G. Lindner, E. Racknagel, 1986. "Chernobyl," Chemtech, October 1986, pp. 596-605. National Center for Radiological Health, 1968.

Radiological Helath and Data Reports, Vol.

9, Number 12, 730-746. Northern States Power Company.

1969 through 1971. Monticello Nuclear Generating Plant, Environmental Radiation Monitoring Program, Annual Report, June 18,1968 to December 31,1968,1969,1970.

Minneapolis, Minnesota.

Northern States Power Company. Monticello Nuclear Generating Plant, Annual Radiation Environmental Monitoring Report to the U.S. Nuclear Regulatory Commission, January 1, to December 31, 1977 through 1982 (prepared by Hazleton Environmental Sciences).

Minneapolis, Minnesota.

1984 through 2000. Monticello Nuclear Generating Plant, Annual Radiation Environmental Monitoring Report to the U.S. Nuclear Regulatory Commission, January 1 to December 31, 1983 through 1999 (prepared by Teledyne Brown Engineering Environmental Services, Midwest Laboratory).

Northbrook, Illinois REFERENCES CITED (continued)

Teledyne Brown Engineering Environmental Services, Midwest Laboratory.

1984a to 2000a. Radiation Environmental Monitoring for Monticello Nuclear Generating Plant, Complete Analysis Data Tables, January - December, 1983 through 1999. 1984b to 2000b. Radiation Environmental Monitoring for Prairie Island Nuclear Generating Plant, Complete Analysis Data Tables, January - December, 1983 through 1999. U.S. Dep't of Energy 1997 HASL-300, Edition 28, Procedures Manual, Environmental Measurements Laboratory, New York, NY. U.S. Environmental Protection Agency . 1980. Prescribed Procedures for Measurement of Radioactivity in Drinking Water, Cincinnati, Ohio (EPA- 60014-80-032).

1 984. Eastem Environmental Radiation Facility, Radiochemistry Procedures Manual, Montgomery, Alabama (EPA-52015-84-006).

2007. RadNet, formerly Environmental Radiation Ambient Monitoring System, Gross Beta in Air, Gross Beta in Drinking Water (MN) 1981- 2005. Wilson, D. W., G. M. Ward and J. E. Johnson. 1969. In Environmental Contamination by Radioactive Materials, International Atomic Energy Agency. p.125.

XCEL Energy Corporation.

2008. Prairie Island Nuclear Generating Plant, Annual Radiation Environmental Monitoring Report to the U.S. Nuclear Regulatory Commission, January 1 to December 31, 2000 through 2007. (prepared by Environmental, Inc., Midwest Laboratory). Northbrook, Illinois

\ ..+.--.3h.-,-L-, /, .... . . -3% . r<+,*,a,- . . . . . . . .- . . .* -.-, - __At. .A:A-. - --, . . . . . . . Environmental, Inc. .... / " Midwest Laboratow

/ an Allegheny Technolog~es Cn. 700 Landwehr Road Northbock, IL 60062-2310 ph. (847) 564-0700 fax (847) 564-4517 APPENDIX A INTERLABORATORY COMPARISON PROGRAM RESULTS NOTE: Environmental Inc., Midwest Laboratory participates in intercomparison studies administered by Environmental Resources Associates, and serves as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada. Results are reported in Appendix A. TLD Intercomparison results, in-house spikes, blanks, duplicates and mixed analyte performance evaluation program results are also reported. Appendix A is updated four times a year; the complete Appendix is included in March, June, September and December monthly progress reports only. January through December, 2007 Appendix A lnterlaboratorv Comparison Proaram Results Environmental, Inc., Midwest Laboratory has participated in interlaboratory comparison (crosscheck) programs since the formulation of it's quality control program in December 1971. These programs are operated by agencies which supply environmental type samples containing concentrations of radionuclides known to the issuing agency but not to participant laboratories.

The purpose of such a program is to provide an independent check on a laboratory's analytical procedures and to alert it of any possible problems.

Participant laboratories measure the concentration of specified radionuclides and report them to the issuing agency. Several months later, the agency reports the known values to the participant laboratories and specifies control limits. Results consistently higher or lower than the known values or outside the control limits indicate a need to check the instruments or procedures used.

Results in Table A-I were obtained through participation in the environmental sample crosscheck program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada.

The results in Table A-2 list results for thermoluminescent dosimeters (TLDs), via International Intercomparison of Environmental Dosimeters, when available, and internal laboratory testing.

Table A-3 lists results of the analyses on in-house "spiked samples for the past twelve months.

All samples are prepared using NlST traceable sources.

Data for previous years available upon request. Table A-4 lists results of the analyses on in-house "blank" samples for the past twelve months. Data for previous years available upon request.

Table A-5 lists REMP specific analytical results from the in-house "duplicate" program for the past twelve month: Acceptance is based on the difference of the results being less than the sum of the errors. Complete analytical data for duplicate analyses is available upon request. The results in Table A-6 were obtained through participation in the Mixed Analyte Performance Evaluation Program. Results in Table A-7 were obtained through participation in the environmental sample crosscheck program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurement Laboratory Quality Assessment Program (EML). Attachment A lists acceptance criteria for "spiked" samples. Out-of-limit results are explained directly below the result.

Attachment A ACCEPTANCE CRITERIA FOR "SPIKED" SAMPLES LABORATORY PRECISION:

ONE STANDARD DEVIATION VALUES FOR VARIOUS ANALYSESa One standard deviation for sinale determination Analvsis Level Gamma Emitters 5 to 100 pcilliter or kg 5.0 pcilliter

> 100 pcilliter or kg 5% of known value 5.0 pcilliter 10% of known value 5.0 pcilliter 10% of known value Potassium40 Gross alpha 2 0.1 glliter or kg 5% of known value 5.0 pcilliter 25% of known value 5.0 pCi1liter 5% of known value Gross beta Tritium *lo = 169.85 x (kno~n)~.~~~~

1O0/0 of known value 15% of known value Plutonium r 0.1 pcilliter, gram, or sample 10% of known value 6.0 pcilliter 10% of known value 6.0 pcilliter 15% of known value 10 pcilliter 10% of known value 20% of known value a From EPA publication, "Environmental Radioactivity Laboratory lntercomparison Studies Program, Fiscal Year, 1981-1 982, EPA-60014-81-004. Laboratory limit.

TABLE A-I . Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a. Lab Code Date Analysis STW-1121 STW-1121 STW-1122 STW-1122 STW-1122 STW-1122 STW-I 122 STW-1123 STW-1123 STW-1124 STW-1125 STW-1125 STW-1125 STW-1125 Sr-89 Sr-90 Ba-133 Co-60 CS-1 34 CS-137 Zn-65 Gr. Alpha Gr. Beta 1-1 31 H-3 Ra-226 Ra-228 Uranium Sr-89 Sr-90 Ba-133 Co-60 Cs-134 Cs-137 Zn-65 Gr. Alpha Gr. Beta Ra-226 Ra-228 Uranium Sr-89 Sr-90 Ba-133 Co-60 CS-134 CS-137 Zn-65 Gr. Alpha Gr. Beta 1-1 31 H-3 Ra-226 Ra-228 Uranium Concentration (pCilL) Laboratory ERA Control ~esult~ ResultC Limits 30.7 + 4.3 35.4 26.7 - 44.1 39.3 + 1.8 42.1 33.4 - 50.8 30.0 + 2.4 29.3 20.6 - 38.0 118.5 ? 3.9 119.0 109.0 - 129.0 52.6 + 2.3 54.3 45.6 - 63.0 49.5 + 3.8 50.3 41.6 - 59.0 91.7 + 6.3 88.6 73.3 - 104.0 33.8 + 3.5 56.5 32.0 - 81 .O 24.2 f 2.3 25.3 16.6 - 34.0 19.2 + 1.2 18.9 13.7 - 24.1 7540.0 + 255.0 8060.0 6660.0 - 9450.0 13.0 + 0.6 13.4 9.9 - 16.9 19.9 + 2.7 18.2 10.3 - 26.1 4.5 + 0.2 4.6 0.0 - 9.8 Acceptance Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass a Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for profic~ency testing in drinking water conducted by Environmental Resources Associates (ERA). Unless otherwise indicated, the laboratory result is given as the mean + standard deviation for three determinations. Results are presented as the known values, expected laboratory precision (1 sigma, 1 determination) and control limits as provided by ERA.

TABLE A-2. Crosscheck program results; Thermoluminescent Dosimetry, (TLD, CaSO,: Dy Cards). mR Lab Code Date Known Lab Result Control Description Value + 2 sigma Limits Acceptance Environmental, Inc. Environmental. Inc.

2007-2 1111212007 2007-2 1111212007 2007-2 1 111 212007 2007-2 1 111 212007 2007-2 1 111 212007 2007-2 1 111 212007 2007-2 1 111 212007 2007-2 1 111 212007 2007-2 1 111 212007 2007-2 1 111212007 2007-2 1 111 212007 30 cm. 40 cm. 50 cm. 60 cm. 70 cm. 80 cm. 90 cm. 100 cm. 110 cm. 120 cm. 150 cm. 30 cm. 40 cm. 60 cm. 70 cm. 80 cm. 90 cm. 110 cm. 120 cm. 120 cm. 150 cm. 180 cm. Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass TABLE A-3. In-House "Spike" Samples Concentration IDC~/L)~ Lab Code Gr. Alpha Gr. Beta Cs-I 34 CS-1 37 H-3 Tc-99 CS-1 34 CS-137 I-131(G) 1-1 31 1-1 31 Cs-134 Cs-137 1-1 31 (G) 1-1 31 1-131 1-1 31 (G) CS-1 34 CS-1 37 1-1 31 (G) Cs-134 CS-137 1-1 31 (G) 1-1 31 (G) 1-1 31 Sr-89 Sr-89 1-131 Fe-55 H-3 Gr. Beta CS-1 34 CS-137 Cs-134 CS-137 Ni-63 Gr. Alpha Gr. Beta Tc-99 Ni-63 Gr. Alpha Gr. Beta iabowioiy iesiiils Known 2s, n=l Activity Conlroi Limits Acceptance Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass TABLE A-3. In-House "Spike" Samples SPW-6880 W-1 1 1007 W-1 1 1007 SPAP-7742 SPAP-7742 SPAP-7744 SPMI-7746 SPM 1-7746 SPMI-7746 SPW-7748 SPW-7748 SPW-7748 SPW-7752 SPW-7758 SPF-7760 SPF-7760 SPW-8034 Concentration (PC~IL)~ Date Anaiysis Laboratory resuits Known Coniroi 2s, n=lb Activity LimitsC Acceptance Tc-99 Gr. Alpha Gr. Beta Cs-134 CS-1 37 Gr. Beta Cs-134 CS-1 37 Sr-90 Cs-134 Cs-I 37 Sr-90 Fe-55 H-3 Cs-134 CS-1 37 Ni-63 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass a Liquid sample results are reported in pCilLiter, air filters( pcilfilter), charcoal (p~ilm3), and solid samples (pcilg). Laboratory codes as follows: W (water), MI (milk), AP (air filter), SO (soil), VE (vegetation), CH (charcoal canister), F (fish). Results are based on single determinations. Control limits are based on Attachment A, Page A2 of this report. Sample recount: 12557 f 335. NOTE: For fish, Jello is used for the Spike matrix. For Vegetation, cabbage is used for the Spike matrix.

TABLE A-4. In-House "Blank" Samples -- - Concentration (DC~/L)~ Lab Code W-30707 W-30707 SPAP-1567 SPW-1567 SPW-I 568 Sample Date

~nal~sis~ Laboratory results (4.660) Acceptance Type LLD ActivityC Criteria (4.66 o) water 3/7/2007 Gr. Alpha 0.40 0.01 + 0.28 2 water 3/7/2007 Gr. Beta 0.75 0.06 r 0.53 4 Air Filter 3/23/2007 Cs-1 34 0.79 100 Air Filter 3/23/2007 Cs-1 37 1.01 100 water 3/23/2007 H-3 176.10 -26.16 + 91.62 200 water water water water Milk Milk Milk Milk Charcoal Canister water water water Milk Milk Milk water water water Milk Milk Milk Air Filter Air Filter Air Filter Fish Fish water water water Cs-134 Cs-137 1-131 1-1 31(G) Cs-I 34 Cs-137 1-131 I-131(G) 1-1 31 (G) CS-134 Cs-137 I-131(G) Cs-I 34 CS-I 37 1-1 31(G) 1-1 31 Sr-89 Sr-90 1-131 Sr-89 Sr-90 Gr. Beta Cs-134 Cs-137 CS-I 34 CS-1 37 Ni-63 Gr. Alpha Gr. Beta water 711 8/2007 Tc-99 6.41 -3.12 It 3.84 water 811 712007 Ni-63 1.48 4.38

+ 1.01 water 9/21/2007 Gr. Alpha 0.41 0.09 + 0.29 water 9/21/2007 Gr. Beta 0.75 -0.26 + 0.51 TABLE A-4. In-House "Blank" Samples Concentration

[DC~IL)~ Lab Code Sample Date

~nalysis~ Laboratory results (4.660)

Acceptance Type LLD ActivityC Criteria (4.66 0) water Air Filter Milk Milk Milk Milk water water water water water water Fish Fish water water water Tc-99 Gr. Beta CS-1 34 CS-137 1-1 31 (G) Sr-90 CS-134 Cs-I 37 1-1 31 (G) Sr-90 Fe-55 H-3 CS-134 Cs-137 Ni-63 Gr. Alpha Gr. Beta a Liquid sample results are reported in pCilLiter, air filters( pcilfilter), charcoal (pcilcharcoal canister), and solid samples (pcilkg).

I-131(G);

iodine-131 as analyzed by gamma spectroscopy. Activity reported is a net activity result.

For gamma spectroscopic analysis, activity detected below the LLD value is not reported. Low levels of Sr-90 are still detected in the environment.

A concentration of (1-5 pCiIL) in milk is not unusual.

TABLE A-5. In-House "Duplicate" Samples Concentration (PC~IL)~ Averaged Lab Code Date Analysis Gr. Beta K-40 Gr. Beta K-40 Sr-90 H-3 Gr. Beta Gr. Alpha Gr. Alpha Gr. Alpha Gr. Alpha Gr. Beta Gr. Alpha Gr. Alpha Gr. Beta Gr. Alpha K-40 Gr. Beta H-3 K-40 Gr. Alpha Gr. Beta Gr. Alpha Gr. Alpha Gr. Beta Gr. Alpha Gr. Alpha Gr. Beta Gr. Alpha Gr. Beta Gr. Alpha Gr. Beta Gr. Alpha Gr. Beta Gr. Beta Gr. Alpha Gr. Beta H-3 K-40 Gr. Alpha Gr. Alpha Gr. Beta Gr. Beta First Result Second Result Result Acceptance Pass Pass Pass Pass Pass \\ Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass TABLE A-5. In-House "Duplicate" Samples Concentration (PC~IL)~ Averaged Lab Code Date Analysis First Result Second Result Result K-40 Sr-90 Be-7 H-3 Be-7 Be-7 Gr. Alpha Gr. Beta Gr. Alpha Gr. Beta Gr. Alpha Gr. Beta H-3 Gr. Alpha Gr. Beta Gr. Alpha Gr. Beta Gr. Alpha Gr. Alpha H-3 Gr. Beta Gr. Beta Be-7 CS-1 37 K-40 Gr. Alpha Gr. Beta Sr-90 H-3 K-40 Gr. Beta Cs-137 K-40 K-40 Gr. Beta 1-131 CS-1 37 Gr. Beta K-40 K-40 Be-7 K-40 Acceptance Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass TABLE A-5. In-House "Duplicate" Samples Lab Code Date Analysis Be-7 Gr. Beta K-40 Gr. Beta H-3 Gr. Alpha Gr. Beta Be-7 Be-7 CS-1 37 Gr. Beta K-40 Gr. Beta Gr. Alpha Gr. Beta Be-7 Be-7 Be-7 Cs-137 Gr. Alpha Gr. Beta K-40 Gr. Beta Gr. Alpha H-3 K-40 Be-7 Gr. Beta K-40 Gr. Alpha Gr. Beta 1-131 CS-137 Gr. Alpha Gr. Beta K-40 H-3 Gr. Beta H-3 H-3 Concentration (QC~IL)~ Averaged First Result Second Result Result Acceptance Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass TABLE A-5.

In-House "Duplicate" Samples Lab Code Date Analysis K-40 H-3 Gr. Beta Gr. Alpha Be-7 K-40 Gr. Beta K-40 K-40 Sr-90 Gr. Alpha Gr. Beta H-3 CS-137 Gr. Beta K-40 Gr. Beta Gr. Beta K-40 Gr. Beta H-3 Gr. Alpha Gr. Beta Be-7 H-3 H-3 Gr. Alpha Gr. Beta K-40 Gr. Beta K-40 Gr. Beta K-40 Sr-90 K-40 H-3 K-40 H-3 Gr. Alpha CS-I 37 Gr. Beta K-40 Concentration (PC~IL)~ Averaged First Result Second Result Result Acceptance Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass TABLE A-5. In-House "Duplicate" Samples Concentration (DC~IL)~ Averaged Lab Code Date Analysis First Result Second Result Result Acceptance Cs-137 K-40 Gr. Beta Gr. Beta K-40 Gr. Alpha

Gr. Beta K-40 1-1 31 K-40 Gr. Beta Gr. Beta Gr. Beta H-3 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Note: Duplicate analyses are performed on every twentieth sample received in-house.

Results are not listed for those analyses with activities that measure below the LLD. a Results are reported in units of pCilL, except for air filters (pCiIFilter), food products, vegetation, soil, sediment (pCi1g).

TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP)a.

Concentration iinown Controi Lab CodeC Date Analysis Laboratory result Activity Limits Acceptance STW-1110 01101107 Gr. Alpha 0.45 + 0.08 0.33 0.00 - 0.65 Pass STW-1110 01101/07 Gr. Beta 0.90 -1 0.14 0.85 0.43 - 1.28 Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass STSO-1 1 12 ' 01/01/07 Am-241 46.40 + 9.00 34.80 24.40 - 45.20 Fail STSO-11 12 01/01/07 CO-57 501.20 +_ 2.90 471.20 329.80 - 612.60 Pass STSO-1 1 12 01 101 107 CO-60 285.90 + 2.10 274.70 192.30 - 357.10 Pass STSO-1 112 01101107 Cs-134 325.90 + 7.40 327.40 229.20 - 425.60 Pass STSO-1 1 12 01/01/07 CS-I 37 855.70 + 4.60 799.70 559.80 - 1039.60 Pass STSO-1 1 12 01/01107 Mn-54 750.90 + 4.70 685.20 479.60 - 890.80 Pass STAP-1113 01/01107 Gr. Alpha 0.27 + 0.04 0.60 0.00 - 1.20 Pass STAP-1113 01101107 Gr. Beta 0.57 _+ 0.05 0.44 0.22 - 0.66 Pass STAP-1114 STAP-1114 STAP-1114 STAP-1114 STAP-1114 STAP- 1 1 1 4 STAP-1114 STAP-1114 STAP-1114 STAP-1114 STAP- 1 1 1 4 STAP-1114 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP)a.

Concentration " Known Control Lab CodeC Date Analysis Laboratory result Activity Limits Acceptance STVE-1115 01/01/07 Co-57 8.90 k 0.20 8.19 5.73 - 10.64 Pass SNE-1115 01/01/07 CO-60 6.50 k 0.20 5.82 4.08 - 7.57 Pass SNE-1115 01/01/07 Cs-134 6.90 + 0.30 6.21 4.35 - 8.07 Pass SNE-1125 01101/07 CS-137 8.20 k 0.30 6.99 4.90 - 9.09 Pass SNE-1115 01/01/07 Mn-54 10.10 k 0.30 8.46 5.91 - 10.98 Pass a Results obtained by Environmental, Inc., Midwest Laboratory as a part~cipant in the Department of Energy's Mixed Analyte Performance Evaluation Program, ldaho Operations office, ldaho Falls, ldaho Results are reported in units of Bqlkg (soil), BqlL (water) or Bqltotal sample (filters, vegetation). Laboratory codes as follows: STW (water), STAP (air filter), STSO (soil), STVE (vegetation).

  • MAPEP results are presented as the known values and expected laboratory precision (1 sigma, 1 determination) and control limits as defined by the MAPEP. Result of reanalysis, 2.08 f 0.13 pCilL. 'The test samples were recounted on lower background detectors. Result of the recounts: 41.4
  • 6.3 Bqlkg.

TABLE A-7. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a. Concentration (pCilL) Lab Code Date Analysis Laboratory ERA Control Result Result a Limits Acceptance Gr. Alpha Gr. Beta Am-241 Co-60 Cs-134 CS-1 37 Fe-55 Mn-54 Pu-238 Pu-239140 Sr-90 U-23314 U-238 Uranium Zn-65 Ac-228 Am-241 Bi-212 Co-60 CS-1 34 CS-1 37 K-40 Mn-54 Pb-212 Pb-214 Pu-238 Pu-239140 S r-90 Th-234 U-23314 U-238 Uranium Uranium Zn-65 Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass TABLE A-7. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a. Concentration (pCilL) Lab Code Date Analysis Laboratory ERA Control Result Result a Limits Acceptance Am-241 Cm-244 Co-60 Cs-134 CS-1 37 K-40 Mn-54 Pu-238 Pu-239140 Sr-90 U-23314 U-238 Uranium Zn-65 Am-241 Co-60 Cs-134 CS-1 37 Fe-55 Mn-54 Pu-238 Pu-239140 Sr-90 U-23314 U-238 Uranium Zn-65 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass a Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurements Laboratory Quality Assessment Program (EML). Laboratory codes as follows: STW (water), STAP (air filter), STSO (soil), STVE (vegetation). Unless otherwise indicated, the laboratory result is given as the mean k standard deviation for three determinations. Results are presented as the known values, expected laboratory precision (1 sigma, 1 determination) and control limits as provided by ERA. 'A high bias (- 20%) was observed in gamma results for air filters. A composite filter geometry was used in the calculations vs. a single filter geometry. Result of recalculation. Cs-137, 305.8 f 6.0 pcilfilter.

'Included in the testing series as a "false positive".

No activity expected.

APPENDIX B DATA REPORTING CONVENTIONS Data Re~ortinq Conventions 1.0. All activities, except gross alpha and gross beta, are decay corrected to collection time or the end of the collection period.

2.0. Sinale Measurements Each single measurement is reported as follows:

xf s where: x = value of the measurement; s = 20 counting uncertainty (corresponding to the 95% confidence level).

In cases where the activity is less than the lower limit of detection L, it is reported as:

< L, where L = the lower limit of detection based on 4.660 uncertainty for a background sample.

3.0. Duplicate analyses 3.1 Individual results: For two analysis results; x, f s, and x, f s, Reported result:

x k s; where x = (112) (x, + x,) and s = (112) dm 3.2. Individual results:

' 4 , < L~ Reported result:

< L, where L = lower of L, and L, 3.3. Individual results:

xfs,<L Reported result: x

+ s if x r L; < L otherwise.

4.0. Com~utation of Averaaes and Standard Deviations 4.1 Averages and standard deviations listed in the tables are computed from all of the individual measurements over the period averaged; for example, - an annual standard deviation would not be the average of quarterly standard deviations. The average x and standard deviation s of a set of n numbers x,, x2 . . . xn are defined as follows:

4.2 Values below the highest lower limit of detection are not included in the average.

4.3 If all values in the averaging group are less than the highest LLD, the highest LLD is reported.

4.4 If all but one of the values are less than the highest LLD, the single value x and associated two sigma error is reported.

4.5 In rounding off, the following rules are followed:

4.5.1. If the number following those to be retained is less than 5, the number is dropped, and the retained number s are kept unchanged. As an example, 11.443 is rounded off to 11.44. 4.5.2. If the number following those to be retained is equal to or greater than 5, the number is dropped and the last retained number is raised by 1. As an example, 11.445 is rounded off to 1 1.45.

APPENDIX C Maximum Permissible Concentrations of Radioactivity in Air and Water Above Background in Unrestricted Areas Table C-I Maximurr!

permissib!e cnncentratisns c? radieactivity in air and water abse ii~tiiial background in unrestricted areasa.

Air (p~ilm3) - -- Water (pCilL) Gmss alpha I x 10-3 Gross beta 1 b Iodine-I 31 2.8 x lo-' Strontium-89 Strontium-90 Cesium-1 37 Barium-1 40 Iodine-I 31 Potassium-40 Gross alpha Gross beta Tritium a Taken from Table 2 of Appendix B to Code of Federal Regulations Title 10, Part 20, and appropriate footnotes.

Concentrations may be averaged over a period not greater than one year. b Value adjusted by a factor of 700 to reduce the dose resulting from the air-grass-cow-milk-child pathway. C A natural radionuclide.

APPENDIX D Sampling Location Maps Figure D-I, Sample Coliection and Analysis program:

TLD locations, Inner ring (Table 5.2).

Figure D-2. Sample Collection and Analysis program: TLD locations, Outer ring (Table 5.2). D-3 Figure D-3. Sample Collection and Analysis program: TLD locations, Controls (Table 5.2).

Figure D-5. Sample Collection and Analysis Program: Radiation Environmental Monitoring Program, Milk, Sludge, Ground Water and Shoreline sampling locations (Table 5-2.)