Final Safety Analysis Report, Rev. 35, Chapter 10, Steam and Power Conversion System
ML17212A051
Person / Time
Site: Millstone Dominion icon.png
Issue date: 06/29/2017
From:
Dominion Nuclear Connecticut
To:
Office of Nuclear Reactor Regulation
Shared Package
ML17212A038 List:
References
17-208
Download: ML17212A051 (55)


Text

Millstone Power Station Unit 2 Safety Analysis Report Chapter 10 MPS2 UFSAR 10-i Rev. 35CHAPTER 10-STEAM AND POWER CONVERSION SYSTEM Table of ContentsSection Title Page10.1

SUMMARY

DESCRIPTION............................................................................10.1-110.2TURBINE GENERATOR.................................................................................

10.2-110.2.1Design Bases.............................................................................................10.2-110.2.1.1Functional Requirements..........................................................................10.2-1 10.2.1.2Design Criteria..........................................................................................

10.2-110.2.2System Description...................................................................................10.2-1 10.2.2.1System.......................................................................................................10.2-1 10.2.2.2Components..............................................................................................10.2-210.2.3System Operation......................................................................................

10.2-210.2.3.1Startup.......................................................................................................10.2-210.2.3.2Normal Operation.....................................................................................

10.2-210.2.4Availability and Reliability.......................................................................

10.2-210.2.4.1Special Features........................................................................................10.2-2 10.2.4.1.1Overspeed Protection Inherent in Normal Operating Control System.....

10.2-310.2.4.1.2Primary Overspeed Trip............................................................................

10.2-310.2.4.1.3Emergency Overspeed Trip......................................................................10.2-4 10.2.4.1.4Testing......................................................................................................10.2-4 10.2.4.1.5 Valves.......................................................................................................10.2-4 10.2.4.2Tests and Inspection..................................................................................10.2-510.2.5Bulk Hydrogen Storage Facility...............................................................10.2-610.3MAIN STEAM SUPPLY SYSTEM..................................................................10.3-1 10.3.1Design Bases.............................................................................................10.3-110.3.1.1Functional Requirements..........................................................................10.3-1 10.3.1.2Design Criteria..........................................................................................

10.3-110.3.2System Description...................................................................................10.3-2 10.3.2.1System.......................................................................................................10.3-2 10.3.2.2Components..............................................................................................10.3-410.3.3System Operation......................................................................................

10.3-410.3.3.1Startup.......................................................................................................10.3-410.3.3.2Normal Operation.....................................................................................

10.3-410.3.3.3Emergency Condition...............................................................................10.3-4 10.3.4Availability and Reliability.......................................................................

10.3-510.3.4.1Special Features........................................................................................10.3-5 10.3.4.2Tests and Inspection..................................................................................10.3-510.4OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM 10.4-1 MPS2 UFSAR Table of Contents (Continued)

Section Title Page 10-ii Rev. 3510.4.1Main Condensers......................................................................................10.4-110.4.1.1Design Bases.............................................................................................10.4-110.4.1.2System Description...................................................................................10.4-1 10.4.1.3Safety Evaluation......................................................................................10.4-210.4.1.4Tests and Inspection..................................................................................10.4-210.4.1.5Instrumentation.........................................................................................10.4-2 10.4.2Main Condensers Evacuation System.......................................................

10.4-210.4.2.1Design Bases.............................................................................................10.4-2 10.4.2.2System Description...................................................................................10.4-3 10.4.2.3Safety Evaluation......................................................................................10.4-310.4.2.4Tests and Inspection..................................................................................10.4-310.4.2.5Instrumentation.........................................................................................10.4-3 10.4.3Turbine Gland Sealing System.................................................................

10.4-310.4.3.1Design Bases.............................................................................................10.4-3 10.4.3.2System Description...................................................................................10.4-3 10.4.3.3Safety Evaluation......................................................................................10.4-410.4.3.4Tests and Inspection..................................................................................10.4-410.4.4Circulating Water System.........................................................................10.4-4 10.4.5Condensate and Feedwater System...........................................................

10.4-410.4.5.1Design Bases.............................................................................................10.4-4 10.4.5.1.1Functional Requirement............................................................................

10.4-410.4.5.1.2Design Criteria..........................................................................................

10.4-510.4.5.2System Description...................................................................................10.4-6 10.4.5.3Auxiliary Feedwater System.....................................................................10.4-6 10.4.5.4Equipment...............................................................................................10.4-1010.4.5.4.1Condensate Pumps..................................................................................

10.4-1010.4.5.4.2Feedwater Heaters...................................................................................

10.4-1010.4.5.4.3Heater Drain Pumps................................................................................

10.4-1010.4.5.4.4Steam Generator Feed Pumps.................................................................10.4-1110.4.5.4.5Steam Generator Feed Pump Turbine Drives.........................................

10.4-1110.4.5.4.6Condensate Polishing Facility................................................................

10.4-1110.4.5.5Safety Evaluation....................................................................................10.4-11 10.4.5.6Tests and Inspection................................................................................10.4-13 10.4.6Steam Generator Blowdown System......................................................10.4-1310.4.6.1Design Bases...........................................................................................10.4-1310.4.6.2System Description.................................................................................10.4-1310.4.6.3Safety Evaluation....................................................................................10.4-1410.4.6.4Tests and Inspection................................................................................10.4-14 10.4.7References...............................................................................................

10.4-14 MPS2 UFSAR 10-iii Rev. 35 CHAPTER 10-STEAM AND POWER CONVERSION SYSTEM List of Tables Number Title10.1-1DELETED10.2-1Turbine Generator Component Description 10.3-1Major Components of Main Steam System 10.3-2Omitted 10.3-3Operating Details for Valve Systems Prot ecting Steam Generations of Overpressure10.4-1Major Components of the C ondensate and Feedwater System10.4-2Failure Analysis of Steam Generator Blowdown System Components MPS2 UFSARNOTE: REFER TO THE CONTROLLED PLANT DRAWING FOR THE LATEST REVISION.

10-iv Rev. 35 CHAPTER 10 - STEAM AND POWER CONVERSION SYSTEM List of Figures Figure Title10.1-1Deleted by FSARCR 03-MP2-007]10.1-2Deleted by FSARCR 03-MP2-007 10.3-1P&ID Main Steam from Generators (25203-26002 Sheet 1) 10.4-1P&ID Condenser Air Removal Water Box Priming and Turbine Building Sump (25203-26012)10.4-2P&ID Condensate System (25203-26005 Sheet 1)

MPS2 UFSAR10.1-1Rev. 35 CHAPTER 10 - STEAM AND POWER CONVERSION SYSTEM 10.1

SUMMARY

DESCRIPTION The components of the steam and power conversion system are de signed to electromechanically produce electrical power using st eam from the steam generators. The steam is condensed, and returned to the steam generators as heated feedwater. The ga seous, dissolved and particulate impurities are maintained within the level acceptable to the steam generators.

The power conversion system includes the turbine generator, main condenser, air ejector and steam packing exhauster, turbine steam dump and bypass system, and th e feedwater pumping and heating system. The heat rejected to the main turbine condenser is transferred to the circulating water system.Steam is generated in two genera tors and supplied to the high pressure section of the turbine. Steam leaving the high pres sure turbine passes through moisture separators and reheaters prior to entering the low pressure sections of the turbine.

A portion of the turbine steam is extracted for feedwater heating. The moisture separator drains, reheater drains, and drains from the top three highest pressure feedwater heat ers are pumped into the feedwate r stream. The drains from the remaining lower three feedwater heaters are cascaded to the condenser.Steam exhausted from the low pres sure turbines is condensed and deaerated in the condenser. The condensate pumps take suction from the condens er hotwell, delivering the condensate through the turbine steam packing exhauster, the condensate polishing demineralizers, the air ejector condenser, and five stages of low pressure feedwater heaters to two turbine-driven steam generator feedwater pumps whose suction and discharge are headered together. Steam generator feedwater pumps discharge feedwater through high pressure heaters into each steam generator.

The condensate and feedwater h eating equipment is duplicate, half-capacity and arranged in parallel trains from the air ejectors to the steam generators. The turbine cycle utilizes all the steam being generated by the steam generators. The turbine steam dump and bypass system is provided to discharge stea m directly to th e condenser during load transient and turbine trip.

If the condenser is not available, steam is discharged to the atmosphere through atmosphe ric dump valves and/or main steam safety valves.The Steam Generator blowdown liquid is normally discharg ed to the circulati ng water outlet, and approximately one-third of the steam generato r blowdown liquid is flas hed to steam and is discharged to the environment via the Unit 2 steam generator blowdown tank vent on the enclosure building roof. When in use, the blowdown quench tank condenses the flashed steam, and non-condensibles are vented to the gaseous waste processing system. Steam generator blowdown from the sample line prior to th e blowdown tank is cont inuously monitored for radioactivity. Blowdown stop, blowdown tank drain, and blowdown quench tank drain valves are closed when high radioactivity is detected. Resi dual quantities in the blowdown system can be manually diverted to the radioactive waste processing system.

MPS2 UFSAR10.1-2Rev. 35TABLE 10.1-1 DELETED MPS2 UFSAR10.1-3Rev. 35FIGURE 10.1-1 DELETED BY FSARCR 03-MP2-007]

MPS2 UFSAR10.1-4Rev. 35FIGURE 10.1-2 DELETED BY FSARCR 03-MP2-007 MPS2 UFSAR10.2-1Rev. 35 10.2 TURBINE GENERATOR 10.2.1 DESIGN BASES 10.2.1.1 Functional Requirements The turbine generator converts steam energy to mechanical ener gy a nd mechanical in to electrical energy. The turbine generator is capable of r eceiving steam with up to 2715 MW thermal energy from the steam generators. The total energy available is converted to 935 MW electrical energy, and the remainder is rejected to the condenser.

A closed regenerative turbine cycle heats the condensate and feedwater and returns it to the steam generators.

10.2.1.2 Design Criteria The following criteria have been used in the design of the turbine-generator: a.The turbine generator shall have the capacity to utilize all the steam produced by the steam generators at full power except that required for auxiliary use.b.The system shall have suitable means of controlling the speed, load, pressure and flow for startup, normal operations and all emergencies such that plant equipment is operated safely and in accordance with the prescribed mode.

c.The system shall be designed to perm it periodic testing of the important components such as main steam stop and control valves, combined intermediate valves, extraction no-return valves, and emergency overspeed trip systems. See Section 10.2.4.2 for a detailed description.

10.2.2 SYSTEM DESCRIPTION 10.2.2.1 System The General Electric turbine generator consists of the turbine, generator, exciter , controls, moisture separator/reheaters, tu rbine lubricating oil, gland seal , stator system winding cooling water system, generator hydrogen sealing syst em and electrohydraulic control system. The moisture separation package and reheat tube bundles for the mois ture separator/reheaters have been replaced with equipment manufactured by the Senior Engineering Company. The General Electric pressure vessels have been retained.The 1,800 rpm turbine includes one double flow high pressure turbine and two double flow low

pressure turbines. Exhaust stea m from the high pressure turbin e passes through two parallel moisture separators/reheaters be fore entering the two low pressu re turbines. The low pressure turbines exhaust steam to the main turbine condenser.

The turbine generator utilizes an electrohydraulic control (EHC) system which governs the speed, load, and flow for startup, ope ration and shutdown. The EHC unit trips the turbine on any of the MPS2 UFSAR10.2-2Rev. 35conditions listed in Section 7.4.6.3.3. Low hydraulic oi l pressure signals ar e supplied from the turbine EHC system to the reactor protective system to trip the reactor. The turbine first-stage pressure is fed to the reactor regulating system as a load reference.

The turbine lubricating oil system supplies lubrication for the bearings. A bypass stream of the turbine lubricating oil flows cont inuously through an oil conditioner at a rate sufficient to process the oil inventory once every six hours.

The generator shaft is provided with oil seals to prevent hydrogen leakage. The generator field excited by an alternator located on the stub shaft of the generator.

The turbine generator supervisory instrumentat ion is provided for ope rational analysis and malfunction diagnosis.

10.2.2.2 Components The major system components and associated performance data are listed in Ta ble 10.2-1.

10.2.3 SYSTEM OPERATION The turbine generator is designed to nor mally operate as a base-loaded machine.

10.2.3.1 Startup The turbine generator is started at 900 psia (cont rolled) steam generator pressure. St artup times and initial speeds are functions of the turbine metal temperature. When the machine is at rated speed, it is synchronized with the electrical 345 kV network and then manually connected to the system.

10.2.3.2 Normal Operation The turbine generator is operated and controlled by the EHC system which combines the turbine generator speed error signals with the generato r load signal to produce the steam flow demand.

The steam flow demand accurately positions the turbine steam flow control valves to maintain the required speed and thereby satisf y the generator load. The turb ine generator is capable of accommodating reactor maximum mane uvering limitations of a power change at a rate of five percent of full power per minute or up to a step change of 10 percent of full power.

10.2.4 AVAILABILITY AND RELIABILITY 10.2.4.1 Special Features The turbine generator is equipped wi th an electrohydraulic control sy stem. It is highly reliable and employs components and s ubsystems of proven high reliabilit y and a completely redundant speed control subsystem (including spee d pickups and logic). Logic is processed in electronic and hydraulic channels.

MPS2 UFSAR10.2-3Rev. 35Valve opening actuation is provided by a 1500 psig hydraulic system which is totally independent of the bearing lubrication system, and utilizes a fire resistant fluid. Valve closing actuation is provided by springs and steam forces upon the reduction or relief of fluid pressure. The system is designed to respond to a lo ss of fluid pressure fo r any reason, and leads to turbine inlet valve closing and consequent turbine generator shutdown.Because of the extreme importa nce of guarding agai nst excessive oversp eed, three lines of defense are provided. These consist of:a.First, during normal operation turbine overspeed is precluded by the governing action of the electro-hyd ra ulic control system by modulating the control and intercept valves. Speed sensing for this control system is provided by three magnetic pickups in conjunction with a toothed wheel on the main turbine shaft.b.The second line of defense against turbine overspeed is the primary overspeed trip system, utilizing the same three magnetic pickups used to provide the control system governing action.c.The third line of defense is provided by the emergency overspeed trip system. This is an independent electrical tripping f unction in which a set of three magnetic pickups, independent from the primary speed signal magnetic pickups, sense the speed of the toothed wheel on the main tu rbine shaft. The primary overspeed trip and emer gency overspeed trip systems constitute two separa te and independent means of protecting the turbine against an overspeed condition.

10.2.4.1.1 Overspeed Protection Inherent in Normal Operating Control System Under normal operation, turbine overspeed is precluded by the governing action of the electrohydraulic control system. Speed sensing fo r this control system is provided by three magnetic pickups in conjunction w ith the toothed wheel on the main turbine shaft. The median value of the three speed signals is used for co nt rol and also for the prim ary overspeed protection logic. The circuitry and software for these control signals is isolat ed from, and independent of, the emergency overspeed trip circuitr y and software. Failure of two of the three primary speed control signals results in a turbine trip.

10.2.4.1.2 Primary Overspeed Trip The turbine protective system consists of a highl y reliable trip manifold assembly along with the EHC system software and hardware. The trip manifold assembly consists of two independent hydraulic circuits arranged in parallel. Each circuit includes three Emergency Trip Devices (ETDs) arranged hydraulically fo r two-out-of-three voting logic. The ETD solenoids, which are de-energized to trip, can be de-energized by either the primary or emergency overs peed protection systems using independent circui ts. If two ETDs in the same hydraulic circuit are de-energized, the EHC fluid trip supply header is isolated and the emergency trip system header is depressurized.

MPS2 UFSAR10.2-4Rev. 35 The primary overspeed trip system utilizes the primary speed pickup signals. The median value of the three signals is compared to the overspeed trip setpoint of 109 percent of rated speed. When the setpoint is reached, the prim ary trip relays de-energize all six ETDs in the trip manifold assembly, removing emergency trip system hydraulic pressure. This causes th e fast closure of the main stop valves and the slower control valves which are in series in the high pressure stage turbine inlet. Also, the trip system pressure rem oval causes the rapid clos ure of the intercept and reheat stop valves which are in series in the in let to the low- pressure stage of the turbine.

10.2.4.1.3 Emergency Overspeed TripThe emergency overspeed trip system utilizes the emergency sp eed pickup signals. The median value of the three signals is compared to the emer gency overspeed trip setpoint of 109.5 percent of rated speed. When the setpoint is reached, the emergency trip relays de-energize all six ETDs in the trip manifold assembly, thereby removing the emergency trip system hydraulic pressure and activating the fast closure of all the turbine steam valves previously mentioned.The emergency overspeed trip sy stem magnetic pickups, I/O modul es, software and processors are independent from the components used fo r control and primary overspeed protection.

10.2.4.1.4 TestingTestability during operation is provided for both the control system and the two overspeed protection systems. The test features provide coverage of the initiating, trippi ng, and controlling devices.10.2.4.1.5 ValvesTwo valves in series are used in the high pressure stage inlet to the turbine.a.Control valves are normally controlled by the redundant speed control system and (tripped) closed rapidly when pressure in the emergency trip fluid system is removed by the redundant trip valves.

The operation of each control valve, in cluding the operating and fast closing devices, can be tested during normal operation.b.Main stop valves are held open by the hydraulic pressure of the emergency trip fluid system and tripped closed ra pidly upon removal of the pressure.

The operation of each stop valve including its fast closing device can be tested during normal operation.Stop valves of the steam-sealed design have been used on ove r 650 General Electric steam turbines since 1948. There have been no reports of a main stop valve fa iling to close, when required, to protect the turbine.

Impending sticking has been disclosed by means of testing so that a planned shutdown could be made to make necessary corrections. This almost always involves MPS2 UFSAR10.2-5Rev. 35 removal of the oxide layer whic h builds up in the stem and bush ing. This oxide buildup does not occur on a low-temperature nuclear application.Combined stop and intercept valves are furnished to prevent the energy stored in reheaters or moisture separators from accelerating the turbine generator to excessive overspeed. These two independently operated valves are arranged in series in one valve body.a.The intercept valves are normally wide open but are closed by the speed control system upon a moderate speed increase and are tripped closed rapidly upon removal of the pressure in the emergency trip fluid system.

The intercept valves are also provided with a st em seal. Each intercept valve, including its fast closing devices, can be tested during normal operation.b.Reheat stop valves are normally open but are closed rapidly upon removal of the pressure in the emergency trip fluid syst em. They are also provided with a steam seal. Each reheat stop valve, including its fast closing de vices, can be tested during normal operation.Thus, there are two independent valves for defense against overspeed in each steam admission line to the turbine. The normal speed control system modulates one of them to prevent overspeed and the overspeed trip systems close both of them on a higher overspeed. All valves are testable during operation and the fast closi ng feature of any valve is fully operative while the valves are being tested.

Where necessary to provide adequate overspeed protection resulting from the energy stored in extraction lines, positive closing nonreturn valves are fitted and actuat ed indirectly by the emergency trip fluid system. Station piping, heater, and check valve systems are reviewed during the design stages to make sure the entrained steam cannot oversp eed the unit beyond safe limits.

The described design, inspection an d testing features adequately preclude the possibility of a destructive overspeed condition from occurring.

10.2.4.2 Tests and Inspection Equipment, instruments and controls are regularly inspected to en sure proper functioning of the system.a.Test the main stop valves and combined intermediate valves fully closed by sequence testing at the EHC control panel.b.Close extraction check valves, equipped with air-operated closing mechanism, part way by operating the test levers.c.Test the fully closed control valves by sequence testing at th e EHC control panel.

MPS2 UFSAR10.2-6Rev. 35d.Test the alarm on the oil tank level gage.e.Check the hydraulic thrust wear detectors.f.Test the overspeed trip systems operati on by using the controls on the EHC panel.g.Deleted by MP-PACKAGE-FSC-MP2-UCR-2013-013.h.Test power load unbalance circuits.

i.Deleted by MP-PACKAGE-FSC-MP2-UCR-2013-013.j.Deleted by MP-PACKAGE-FSC-MP2-UCR-2013-013.k.Lift pump test.

l.Check automatic starting of turbine motor-driven oil pumps.m.Deleted by MP-PACKAGE-FSC-MP2-UCR-2013-013.n.Check main stop and control valve tightness.

o.Test automatic pump starting.p.Deleted by MP-PACKAGE-FSC-MP2-UCR-2013-013.The moisture separator reheaters are tested periodically for tube leaks.

The detectable flaw size in th e rotating members of the turbine generator is several orders of magnitude smaller than any cri tical crack which might develop from normal operation and could possibly result in a rotor failure.

10.2.5 BULK HYDROGEN STORAGE FACILITY The bulk hydrogen storage facility is located outside, on the west side of Unit 2 Turbine building.

A firewall is provided between the Turbine building and the Hydrogen Storage Facility. The cylinders are isolated from pe rsonnel by a chain link fence. "N o Smoking" signs and "Hydrogen Flammable Gas - No Open Flames" signs are posted per NFPA requirements. The H 2 bulk supply header is run above ground from H 2 bulk storage area to the Unit 2 Turbine Building west wall.

An excess flow check valve is installed on the hydrogen supply piping outside the Turbine building. The H 2 distribution headers inside Unit 2 are run as follows:1.Headers are located to prevent physical damage to pipe.

MPS2 UFSAR10.2-7Rev. 352.Headers are located as safe distances from equipment that present a fire hazard to H 2.3.Headers are run through well-ventilated areas.4.H 2 piping is provided with guard pipes.

The equipment supplied with H 2 is the volume control tank and the main turbine generator. The following protective measures are provided to prevent fire s and explosions during operation:1.Volume Control Tank During normal operation N 2 and H 2 are supplied to the volume control tank pressure-reducing valves at a maximum pres sure of 75 psig. If a tank leak occurs there is adequate ventilation to exhaust the H 2 to the atmosphere. During purging, N 2 is used to purge that tank to the gaseous waste processing system.2.Main Turbine Generator During normal operation, H 2 at 60 psig is used to cool the turbine generator rotor. To prevent H 2 from leaking through the generator sh aft seal glands into the turbine building, a shaft oil seali ng system is provided. During purging of the H 2 from the generator, CO 2 is used to prevent fi res and the mixture of H 2 and CO 2 is exhausted through a vent line to the outside atmosphere.

MPS2 UFSAR10.2-8Rev. 35TABLE 10.2-1 TURBINE GENERATOR COMPONENT DESCRIPTIONTurbineSteam generator power, rated design/(MWth) 2715Throttle steam pressure, rated design (psia)870

Main steam moisture content, max (%)

0.2 kW output, rated-design 935, 338 Makeup (%)

0Turbine backpressure, (inches Hg abs) 2.0 Points of extraction 6Note:The MP2 original licensed power was 2607 MWth Steam Generator Power.

License up-rating took place during 1979 to stretch power of 2715 MWth Steam Generator Power.

GeneratorRating (kVA) 1,011,000 Power factor 0.9Voltage (volts) 24,000Hydrogen pressure (psig) 60 MPS2 UFSAR10.3-1Rev. 35 10.3 MAIN STEAM SUPPLY SYSTEM 10.3.1 DESIGN BASES 10.3.1.1 Functional RequirementsThe main steam system (MSS) will perform the following functions:a.Deliver steam from the steam generators to the turbine generator from warmup to valve wide open flow and pressure.b.Provide steam for turbine gland seals, steam jet air ejectors (SJAE), moisture separators reheaters, a nd steam generator main a nd auxiliary feedwater pump (AFP) turbines.c.Transfer heat generated by the nuclear steam supply system (NSSS) to the condenser or atmosphere in the event the turbine generator is out of service.

10.3.1.2 Design Criteria The following design criteria have been used in the design of the main steam supply system:a.The steam line leaving each steam generator is equipped with isolation valves located outside the containment. The isol ation valves are designed to function so as to isolate a steam generator in the even t of a rupture of the steam piping at any point, and to maintain at least one steam ge nerator as a heat si nk to remove reactor decay and sensible heat.b.Each main steam line is provided with sp ring-loaded safety valves upstream of the isolation valves. The total relieving capaci ty is in excess of 100 percent steam flow at 2700 MWt rated thermal power. The safety valves discharge to the atmosphere.c.A steam generator AFP turbine is supplied with steam from eith er main steam line upstream of the isolation valves.d.The main steam supply syst em is provided with an au tomatically actuated steam dump system and turbine bypass to control steam pressure (hence, reactor coolant temperature) at hot standby zero load operation and to remove reactor coolant system (RCS) stored energy following a tu rbine trip. Atmospheric dump valves (ADV) from each steam generator are pr ovided to limit or control secondary pressure whenever the condenser is out of service. Either steam dump system to the condenser or the atmosphe ric dump is capable of cool ing the plant to the point of shutdown coolin g manua l initiation.

MPS2 UFSAR10.3-2Rev. 35e.The main steam piping, from the steam generators up to and including the main steam isolation safety valves and steam dump to atmosphe re valves, is designed to withstand a Clas s I seismic disturbance.f.The main steam piping from the main steam isol ation valves (MSIV) to the turbine stop valves is designed to with stand dyna mic loading resulting from rapid closure of the turbine stop valves.

An analysis was performed on the 34 inch Atwood and Morrill main steam isolation swing check valve under the dynamic loads associated with postulated steam line breaks.The valve disc kinetic energy was calculated by determining its velocity at the time of impact with the seat. The forces acting on the disc due to steam pressure we re integrated with time to determine the terminal velocity. The pressures were calculated assuming a full area break on the main steam line under maximum flow conditions. The flow conditions were evaluated at different degrees of disc closure and the effects of choked flow were considered.

The inner portion of the disc and the point of im pact on the body casting go plastic during impact. However, the zones of plastic deformation at any instant of time are surrounded by a sufficient amount of material in the elasti c stress range to prevent failure.The stresses were calculated using the SAAS com puter program. The SAAS was a state-of-the-art program at the time the analysis was performed. Th e SAAS program is a fini te element code that calculates the time hist ory of stresses due to impact on an elastic basis.

Although this analysis proved th at a failure of the MSIV disc would not occur, several modifications were made by Atwood and Morrill to preclude the possibility of local surface

failures at the farthest point from the disc arm. The modificat ions consisted of increasing the seating area and a redesign of th e disc from a flat configurati on to a shallow spherical shell configuration.

10.3.2 SYSTEM DESCRIPTION 10.3.2.1 System The main steam supply system is shown in Fi gure 10.3-1. The main steam pi ping consists of two parallel 34 inch OD lines and terminates at the 34 inch cross tie header which manifolds to the four turbine stop valves.

Each steam line has eight spring-loaded safety valves, set to sequentially discharge to the atmosphere. The spring-loaded sa fety valves have setpoints ra nging from 985 psig to 1035 psig, and the total relieving capacity for all valv es on all of the steam lines is 12.7 x 10 6 lb/hr, which is 108 percent of the total secondary steam flow of 11.8 x 10 6 lb/hr at 100 percent rated thermal power. See Section 4.3.2 for more details.

MPS2 UFSAR10.3-3Rev. 35 The atmospheric steam dump system consists of one automatically actuated dump valve for each steam generator which exhausts to the atmosphe re. The total atmospheri c dump system capacity is 15 percent of 2700 MWt rated thermal power. The turbine bypass and dump-to-condenser system consists of four automatically actuated valves which exhaust to the condenser. It has a total capacity of approximately 40 percent of the 2700 MWt rated thermal power. The system control valves are arranged for automatic opera tion but can be manually operated. More details may be found in Section 7.4.5.

The MSIV assemblies are located outside of and adjacent to the containment building. Each consists of an air-operated trip valve adjacent to a fr ee swinging, reverse flow check valve and a motor-operated bypass valve.Each air-operated trip valve is equipped with a separate auxiliary air accumulator to assure an air supply for its operation if the normal air supply fails.

A pressure switch alarms in the control room in the event of loss of air supply to the accumulator. The mechanism has a spring-assist feature which closes if there is a loss of air in the accumulators or if it is vented by a solenoid pilot. The trip valve component of the assembly protects the steam generator and reactor from damage in the even t a rupture occurs in the main steam line downstream of the isolation valve.

Closing of the isolation valve within a max imum of six seconds after a command signal is initiated prevents rapid flashing and blowdown of water stored in the shell side of the steam generator, thus avoiding a rapid uncontrolled cooldown of the RCS.

As an auxiliary function, the isolation valves also prevent th e release of the contents of the secondary side s of both steam generators in the event of a r upture in one main steam line upstream of the valves. During normal operation these valves remain ope

n. Low steam generator pressure or high c ontainment pressure causes a steam generator isolation signal to energize the closing mechanism of the valves to stop the steam flow through the main and bypass valves.

Four pressure transmitters on each steam generato r are monitored by four independent bistables.

Upon low pressure in eith er steam generator and 2-out-of-4 coincidence bist able trip signals, both air-operated MSIVs are closed.Automatic closure of the air-ope rated MSIVs via the low steam ge nerator pressure signal can be manually blocked to permit orderl y startup and shutdown of the uni t (see Section 7.3). The high containment pressure signal cannot be blocked.

One 4-inch line is provided from each main steam line upstream of the MSIV to feed the AFP turbine.

Each steam supply line from the respective main st eam line to the AFP turbine is equipped with a check valve and a remote (main control room) manual motor-operate d gate valve for isolation to prevent the blowdown of the isolated steam generator in the event of a steam line break at the other steam generator. Each of the remote, manual, motor-operated gate valves has an upstream drain line with a manual isolation valve. This valve can be opened for draining the upstream side MPS2 UFSAR10.3-4Rev. 35of a gate valve while an operator is in attendance. These valves will otherwise be maintained in the "locked closed" position while containment integrity is required.

Seismic Class I design requireme nts are placed on the main steam line, bypass piping, branch lines to auxiliary feedwater pum ps and to the atmospheric dump valves, up to and including the isolation trip valve outside the containment. This includes the piping up to and including the main steam safety valves, the atmospheric dump valv es and the steam generators. All downstream components are designed to seismic Class II requirements.

10.3.2.2 ComponentsTable 10.3-1 describes the major components of the main steam system.

10.3.3 SYSTEM OPERATION 10.3.3.1 StartupSteam produced by the steam generator is bypassed from the turb ine generator to the condenser to maintain steam generator pressure and temperature at 900 psia and 532

°F. Steam flow is increased according to the turbine metal temperature-steam temperature differentials. Steam flow to the steam generator feed pump (SGFP) turbines is changed from high to low pressure and the condenser air removal mode changed to SJAE operation from mechanical pump operation, according to moisture separa tor pressure and main steam availability, respectively.

10.3.3.2 Normal Operation Main steam is led to the turb ine stop valve inlet headers fr om each steam generator through separate 34-inch OD main steam lines to the turbine with no steam bypassed and the generator producing steam as required by the turbine generator. Feedwater flow is controlled by the feedwater control valve constant differential characteristic which adjusts feedwater flow; therefore, steam flow is according to steam demand.

10.3.3.3 Emergency ConditionDuring a reactor-turbine trip from full power, the four (4) steam d ump to condenser valves (CDVs) and the two (2) main steam dump to atmo sphere valves (ADVs) are fully open within four (4) and five (5) seconds, respectively, to avoid lifting of the safety valves. These limiting stroke times include any contro l circuit processing time. In th e event of a loss of condenser vacuum, the steam dump to condenser valves close automatically. The ADVs open at a preset steam pressure of 920 psig to exhaust the steam generated by decay heat. The atmospheric dump capacity, equivalent of 15 percent of 2700 MWt (rated thermal power), is sufficient to cool the RCS to 300

°F when shutdown cooling is initiated. A flow equivalent to 55 percent of 2700 MWt is sufficient to prevent lifting of the main steam safety valves. As the RCS approaches the shutdown cooling temperature, the steam pressure also decreases and if the bypass valve capacity is not sufficient to continue the desired rate of cooldown, the operator ca n partially open the steam dump to condenser or the ADVs to obt ain the desired rate of cooldown.

MPS2 UFSAR10.3-5Rev. 35 Under normal operation, the ADV wi ll not open. A steam dump va lve is assumed to open inadvertently for the accident an alysis Sections 14.1.3 and 14.1.4 address increa se in steam flow events that bound the inadvertent opening of an ADV. The inadvertent operation of these valves is unlikely.Assuming a double-end break of an individual auxiliary steam supply line upstream of the common header and check valve with the reactor at rated ther mal power (2700 MWt), (see Figure 10.3-1), the check valv es will prevent one steam ge nerator from blowing down and the other steam generator will blowdown at the rate of 133 pounds per second causing the reactor power to reach 105 percent of full power. This condition will continue until the operator stops the feedwater to the steam generator associated with the break and shuts down the plant. No additional protective action is required.Assuming the line breaks in either one of the 4 inch auxiliary st eam supply lines downstream of the check valves or on the common header and with the reactor at 100 percent power, the steam flow through each of the 4 inch lines is 133 pounds per second. The re actor power will increase to 109 percent of full power and will stay at this new steady stat e condition. Each steam generator will continue to blowdown thr ough the break until the operator cl osed the remote-manual, motor operated isolation valves in the 4 inch lines, at which time the reactor will return to its initial power level. No other pr otective action is required.The feeding of the steam generators using AFW combined with the dumping of steam to the environment through the atmosphe ric steam dump valves may be employed to provide long-term cooling during a LOCA. This w ould be required post-LOCA when the shutdown cooling system cannot be placed into operation or during simultaneous hot a nd cold leg injection. During a LOCA event, an aggressive cooldown rate is to be initiated and maintained, using the atmospheric steam dump valves, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> after the start of the accident and at a minimum rate of 40

°F/hr, until steam removal from the st eam generators becomes limite d by the fully open atmospheric steam dump valves.

10.3.4 AVAILABILITY AN D RELIABILITY 10.3.4.1 Special Features The main steam piping, the isolation valves, the atmospheric dump, the main steam safety valves and the steam generators are designed in a ccord ance with seismic Class I requirements.

Three self-operating valve systems, using separate components, protect th e steam generator from overpressure; however, safety valves alone can do the job. Each system operates as given inTable 10.3-3.

10.3.4.2 Tests and InspectionSee Section 5.2.7.4.2 and Technical Specifications Section 4.7.1.5.

MPS2 UFSAR10.3-6Rev. 35Three inch motor-operated bypass valve assemblies provided for each 34 inch valve assembly.

The applicable codes and material are similar to those for the main steam swing disc trip valves.

TABLE 10.3-1 MAJOR COMPONENTS OF MAIN STEAM SYSTEMMain Steam Isolation Valves DescriptionMain steam swing check valves, 600 pound ANSI, carbon steel, butt-welded endsMain steam swing disc trip valves, air cylinder operated 600 pound ANSI, butt-welded ends, carbon steel.ManufacturerAtwood & MorrillAtwood & Morrill Size 34 inch34 inchCodes and Standards ANSI B31.1.0 a , B16.10, B16.25 MSS-SP-25, -55, -61a.Except weld reinforcement requirements of Code Case 83 shall apply.

Draft ASME Code for pumps and valves for nuclear power, November 1968; including 1970 Addenda, Code Case 1427Material BodyCast steel ASTM A216 Gr WCBCast steel ASTM A-216-Gr WCBDiscCast steel ASTM A216 Gr WCBCast Steel ASTM A216 Gr WCBShaftStainless steel ASTM A276 Type 410Steel bar ASTM A-276 Type 410Design pressure / temperature1000 psig/600

°F1000 psig/600

°FMain Steam Dump to Atmosphere Description600 pound ANSI, cast steel, butt-welded ends, diaphragm operated.ManufacturerCopes-Vulcan Size 8 inchCodes and StandardsASME Code for Pumps and Valves for Nuclear Power Class II; ASME Code Case 1427; ANSI B16.5, -B16.10, -B16.25; MSS-SP-6, -25, -45, -53, -55, -61, -66.Material BodyCast steel ASTM A-216 Gr WCB PlugStainless steel ASTM A276 Type 420StemStainless steel ASMT A-276 Type 316-B MPS2 UFSAR10.3-7Rev. 35 Piping - See Table 10.4-1.Main Steam Safety Valves -

See Section 4.3.2 for details.Conditions and CharacteristicsQuick opening time (seconds)5 or lessInlet pressure (no-load steam generator pressure less piping losses) (psia) 896Temperature ( °F)530Differential pressures (psi)829Maximum differential pressure (psi)985Total combined flow rate (2 valves)(lb/hr)1,770,450Modulating service stroke time, max (seconds)10Turbine Bypass to Condenser Description600 pound ANSI, cast steel, butt-welded ends, pneumatically operated piston actuator Size12 inch inlet x 14 inch outletCodes and StandardsANSI B16.10, B16.25, B31.1; MSS-SP-25, -45, -53, -55, -61, -66; ASME B16.34; ISA S75.01Material BodyCast steel ASTM A-216 Gr WCB PlugStainless steel Commercial ASTM - A479 - 410StemStainless steel ASTM A-276 - 410Conditions and CharacteristicsDump modeBypass modeQuick opening time (sec)4 or less N/A Inlet pressure (psig) 822879Outlet pressure (psig) 155155Steam stateDry, saturatedDry, saturatedTotal combined flow rate (lb/hr)4,850,000590,150Modulating service, max (lb/hr)4,850,000590,150 Modulating service, stroke time (sec) 10 max10 max MPS2 UFSAR10.3-8Rev. 35TABLE 10.3-2 OMITTED MPS2 UFSAR10.3-9Rev. 35TABLE 10.3-3 OPERATING DETAILS FOR VALVE SYSTEMS PROTECTING STEAM GENERATIONS OF OVERPRESSUREValve DescriptionNumber Of Valves Actuating Inlet Pressure (psia)ModeSteam dump bypass to condenser4; one bypass900Quick open; modulated on

reactor T aveAtmospheric dump2; one for each steam generator920Pressure controller Main steam safety valves16; 8 on each line1000,1005 1015,1025 1035,1045 and 1050 Pressure controlled spring-loaded MPS2 UFSAR10.3-10Rev. 35FIGURE 10.3-1 P&ID MAIN STEAM FROM GENERATORS (25203-26002 SHEET 1)

The figure indicated above represents an engineering controlled drawing that is Incorporated by Reference in the MPS-2 FSAR. Refer to the List of Effective Figures for the related drawing number and the controlled plant drawing for the latest revision.

MPS2 UFSAR10.3-11Rev. 35FIGURE 10.3-1 P&ID MAIN STEAM GENERATOR BLOWDOWN SYSTEM (25203-26002 SHEET 2)

The figure indicated above represents an engineering controlled drawing that is Incorporated by Reference in the MPS-2 FSAR. Refer to the List of Effective Figures for the related drawing number and the controlled plant drawing for the latest revision.

MPS2 UFSAR10.3-12Rev. 35FIGURE 10.3-1 P&ID MAIN STEAM TURBINE AND REHEATER 1A (25203-26002 SHEET 3)The figure indicated above represents an engineering controlled drawing that is Incorporated by Reference in the MPS-2 FSAR. Refer to the List of Effective Figures for the related drawing number and the controlled plant drawing for the latest revision.

MPS2 UFSAR10.3-13Rev. 35FIGURE 10.3-1 P&ID MAIN STEAM TURBINE (25203-26002 SHEET 4)

The figure indicated above represents an engineering controlled drawing that is Incorporated by Reference in the MPS-2 FSAR. Refer to the List of Effective Figures for the related drawing number and the controlled plant drawing for the latest revision.

MPS2 UFSAR10.4-1Rev. 35 10.4 OTHER FEATURES OF STEAM AND POWER CONVERSION SYSTEM 10.4.1 MAIN CONDENSERS 10.4.1.1 Design Bases The purpose of the condenser is to provide a heat sink for the turb ine exhaust steam, main steam dump and bypass and other flows. It also deaer ates and provides stor age for the condensate.

The main condenser is designed for the following conditions:

Condenser duty (Btu/hr) 6059 x 10 6 Condenser pressure (inch Hg absolute) 2.07 Circulating water temperatureInlet (°F) 60.8 Outlet (°F) 84.8 Flow (gpm) 522,500 total Heat transfer area (square feet) 485,260 total Design pressure Shell (inches Hg vacuum) 29.5Waterbox (psig) 25 The condenser is designed to a ccept up to 40 percent of the design main steam flow (vwo) through the steam dump and bypass valves while maintaining turbine back pressure below 5 inches. Hg absolute without exceeding th e allowable turbine exhaust temperature.

The condenser hotwell has four minut es of vwo flow storage capacity

.The condenser is designed to deaerate the condensate properly, to provide condensate of the required quality and to remove noncondensable gases and air in leakage from the condensing steam.10.4.1.2 System Description During planned operation, steam fr om the low pressure turbine is exhausted directly downward into the condenser shells through exhaust openings in the bottom of the turbine casings. The condenser consists of two sections, each section serving one double-flow, low pressure turbine section. The condenser also serves as a heat sink for several othe r sources, such as exhaust steam from feed pump turbines, cascad ing heater drains, ai r ejector condenser drain, steam packing exhauster condenser drain, feedwa ter heater shell operating vent s and condensate pump suction vents.

MPS2 UFSAR10.4-2Rev. 35 During abnormal conditions, the c ondenser is designed to recei ve steam dump and bypass steam and feedwater heater and moisture separa tor/reheaters drain tank high level dump(s).

The condenser is a single-pass, single-pressure deaerating type with divided water boxes. The condenser is supported on the turbine foundation ma t with expansion joints provided between each turbine exhaust opening a nd the steam extraction connecti ons in the condenser shells.

Condenser shells are connected by a pressure equalizing duct.

Dearation in the condenser removes normal inleakage of air plus noncondensable gases contained in the turbine steam. The noncondens able gases are then collected in the air cooling section of the condenser, from which they are removed by the mechanical vacuum pump at startup and by the steam jet air ejectors (SJA E) during normal operation.

10.4.1.3 Safety Evaluation The condenser is designed to store a suff icient volume of conde nsate to provide a three minute effective retention time of the condensate for radioactive decay in the event of tube leakage of the steam generator.

10.4.1.4 Tests and InspectionThe condenser is built in accordan ce with Heat Exchanger Institute (HEI) standards fo r the steam surface condensers. The water boxe s shall be tested in accordance with these standards. After erection, the condenser will be filled with water to check tube and other leaks.

10.4.1.5 Instrumentation Condenser vacuum and temperature are monitored continuously. Ne cessary alarm and trip signals are provided for high pressure and exhaust hood temperatures. Th e condenser hotwell level is controlled by level controllers. C onductivity elements in ea ch effluent line detect any inleakage of the circulating water into the condenser steam space.

Redundant conductivity elements ar e provided, one in each condenser outlet line to detect in leakage of circulating water into the feedwate r system. Each conductivi ty cell output is continuously recorded. High conductivity will be alarmed in the Control Room.

10.4.2 MAIN CONDENSERS EVACUATION SYSTEM 10.4.2.1 Design Bases The main condenser evacuation system is de signed to remove a to tal of 80 scfm of noncondensable gases in accor dance with HEI standards.

MPS2 UFSAR10.4-3Rev. 35 10.4.2.2 System Description The main condensers evacuation system, as shown in Figure 10.4

-1, includes two SJAE units complete with inter- and after-condensers wh ich remove air and nonconde nsable gases from the main condenser. A mechanical vacuum pum p is provided for use during startup.

Main steam, reduced in pressure by an automatic steam-pressure reducing station, is supplied as the driving medium to the twin element two-stage air ejectors. Ai r ejector condenser cooling is provided by the main condensate flow. Air inleakage and nonc ondensable gases are removed from the condenser and discharg ed to the Millstone stack whic h is continuously monitored for radioactivity.Two full capacity mechanical vacuum pumps re move air and noncondens able gases from the condenser during startup and when the desired rate of air and gas removal exceeds the capacity of the air ejectors. The discharge from the vacuum pump is routed to the Millstone stack.

10.4.2.3 Safety Evaluation A radiation monitor is provided in the air ejector vent line to the Millstone stack to detect primary to secondary leakage in the steam generators. U pon a high radiation signal an alarm is actuated and checks of the monitor alarm and possible leakage sources and rates are instigated.

10.4.2.4 Tests and InspectionThe air ejector inter- and after-c ondensers are hydrostatically tested at the manufacturer's plant in accordance with HEI standards.

Mechanical vacuum pumps a nd air ejectors first and second stages are performance tested at the factory for the design capacity.

10.4.2.5 InstrumentationAll necessary instrumentation is provided for normal and abnormal operations.

10.4.3 TURBINE GLAND SEALING SYSTEM 10.4.3.1 Design BasesThe turbine gland seal system provides a means of sealing the turbine shaft and valve stem packing against air leakage into the cycle and to prevent steam leakage into the Turbine Room.

10.4.3.2 System Description The turbine gland sealing system, consists of a main steam source, steam seal pressure regulator, steam seal header , one full capacity steam packing ex hauster with two full capacity blowers and the associated piping and valves.

MPS2 UFSAR10.4-4Rev. 35 During planned operation, one blower is operating while the other is on standby. The exhaust blower discharges gland air leakage to the Millst one stack. The steam packi ng exhauster is cooled by main condensate flow and is drained to the main condenser.

10.4.3.3 Safety Evaluation The radiation monitor for the Mill stone stack would alar m any high radioactive releases from this system.

10.4.3.4 Tests and Inspection The gland seal condenser is de signed in accordance with Amer ican Society of Mechanical Engineers (ASME)Section VIII and is hydrostatically tested.

10.4.4 CIRCULATING WATER SYSTEM This system is described in Section 9.7.1.

10.4.5 CONDENSATE AND FEEDWATER SYSTEM 10.4.5.1 Design Bases 10.4.5.1.1 Functional Requirement The function of the condensate and feedwater system is to proces s the condensate and provide the required amount of feedwater to the steam generators. The c ondensate and feedwater system provides feedwater heating and maintains the required quality of feedwater.

The auxiliary feedwater system (AFWS) is compri sed of two full-capacity subsystems to satisfy two safety functional requirement

s. One subsystem consists of two motor driven, automatically initiated AFW pumps. The second subsystem consists of one turbine-driven pump.

The first safety functional require ment is to provide cooling to either steam generator, on low-steam generator level, with or without the loss of normal AC pow er along with the most limiting single failure. The arrangement of these two independent subsystems ensures that the auxiliary feedwater system can accomplish this functional requirement.

The second functional requirement is that AFW must be delivered to the steam generators independently of AC power in the event of a st ation blackout scenario. The turbine-driven AFW pump performs this second function.

MPS2 UFSAR10.4-5Rev. 35 10.4.5.1.2 Design Criteria The following criteria have been used in th e design of the condensate and feedwater system:a.The system shall provide 110 percent of the valve wide open flow at 935 psig at the steam generator feedwater nozzles.b.The system shall maintain the required volume and quality of water in the cycle.c.The system shall process and provide a cont rolled path for the fluids in the cycle.d.The system shall provide sufficient f eedwater for the cold shutdown of the RCS.The design of the feedwater piping system had been modified to ensure that the loop seals were provided in the piping as close to the steam generator feedwater in let nozzles as possible. These modifications had been provided in lieu of perf orming analyses using d ynamic forcing functions associated with the draining of feedwater lines to qualify the piping system design.

The design of the feedwater piping has also been modified to the interface requirement for the design associated with steam ge nerators installed in 1991. The m odified feedwater design retains the water hammer mitigation desi gns described in the previous paragraph but accommodates the 1991 steam generator's lower prim ary deck (below the normal wa ter level), lower feedwater sparger ring, top discharge J-tubes, all welded thermal sleeve and a goose neck inlet design.

The following criteria have been used in the design of the AFWS:a.The system shall have two redundant, i ndependent subsystems, each capable of performing the functional requirements. The turbine-driven pump and associated piping is one subsystem. The two motor driven pum ps and associated piping is the second subsystem.b.The system shall have suitable subsystem and component alignments to assure operation of a complete subsystem with associated components.c.Capabilities shall be provided to assu re the system operati on with onsite power (assuming offsite power is not available) or with offsite electrical power.d.A single failure of an active component in either subsystem shall not affect the functional capability of the other subsystem.

e.The system shall be designed to pe rmit periodic inspection of important components such as pumps, valves, piping and tanks to assure the integrity and capability of the system.f.The system shall be designed to th e general criteria as described in Section 6.1.

MPS2 UFSAR10.4-6Rev. 35g.The AFWS is automatically initiated upon detection of low steam generator level.

10.4.5.2 System Description The condensate and feedwater system is shown in Figure 10.4-2.

The condensate pumps take conde nsate from the condenser hotwe lls and pump it through the condensate polishing demineralizers and the steam packing exhauster. The flow is then split into two streams. Each stream passes through an ejector condenser, an external drain cooler and sixth-and fifth-stage feedwater heaters located in the condenser neck a nd three low pressure feedwater heaters and one high pressure heater.The SGFPs are located in the cycle between the lo w pressure heaters and the high pressure heater.To maintain the proper feedwater chemistry a secondary chemical feed system is provided for injecting hydrazine as an oxygen scavenger and ethanolamine (ETA) to control pH. The rate of chemical injection is controlled to maintain chemistry within the desired limits. The point of chemical injection during norma l operation is in the condensat e return header from the Condensate Polishing Faci lity (CPF), upstream of the bypass valve. An alternate point of injection, when the CPF is bypassed, is in the CPF discharge header downstrea m of the CPF bypass valve and upstream of the steam jet air ejectors.

Feedwater regulating and contro l is described in Section 7.4.

10.4.5.3 Auxiliary Feedwater System The AFWS, shown in Figure 10.4-2, is designed to provide feedwater for the removal of sensible and decay heat, and to cool the primary system to 300

°F in case the main condensate and SGFP are inoperative due to loss of normal electric power sources or the main steam. A single motor-driven pump is capable of adequately removing de cay heat. This has been demonstrated by a best estimate analysis of th e loss of feedwater event (Reference 10.4-1). The best estim ate analysis is performed to demonstrate the automatic start of both motor driven auxiliary feedwater pumps on low steam generator level satisfies the automatic auxiliary feedwater in itiation requirements of NUREG-0737 item II.E.1.2. Automatic st art of the turbine driven a uxiliary feedwater pump is not required. The suction condition yi elds a net positive suction he ad (NPSH) in excess of that required. The AFWS may also be used for normal system cooldown to 300

°F. The AFWS supplies feedwater from the c ondensate storage tank (CST) to the steam generators for evaporation and heat absorption. R eactor decay heat and se nsible heat are tran sferred to the steam generators by natural circulation of the reactor coolant if power is not available for the reactor coolant pumps (RCP).

In order to perform its safety-related function (per Section 14.2.

7) assuming single failure, the auxiliary feedwater system (AFWS) is comprised of tw o full capacity subs ystems. One subsystem consists of two motor driven AFW pumps, that are automatically connected to the diesel generators in the event of a loss of offsite power. Th e second subsystem consists of one turbine-driven pump that is inde pendent of AC power a nd may be started by operator action. The turbine-MPS2 UFSAR10.4-7Rev. 35 driven pump has a maximum cap acity of 600 gpm at 2437 feet de sign head (TDH) and the two motor driven pumps have a constant 300 gpm capacity each at 2437 feet TDH.The two motor driven auxiliary feedwater pumps (AFP) receive d their power from redundant Facility 1E 4160VAC breakers. The 4160 VAC breakers receive control power from redundant 125VDC feeds, Facility Z1 125 VDC panel DV 10 and Facility Z2 125 VDC panel DV20. The speed adjuster motor and the steam inlet valve for the turbine-driven AFP normally receive their power from Facility Z2 125 VD C panel DV20. During design basis accidents coincident with a single failure that could di sable one motor driven AFP and the turbine-driven AFP simultaneously, the steam inlet valve and the speed adjuster motor are capable of being transferred to Facility Z1 125 VD C panel DV10. In the event of a lo ss of Facility Z2 125 or a loss of DC panel DV20, the transfer is accomplished by switching the position of two key-locked isolation switches on panel C-05. Th e associated wiring from panel C-05 is routed in dedicated Z5 conduit to panel C-21, pane l C-10 and ultimately to the steam inlet valve and the speed adjuster motor.The auxiliary feedwater pumps (AFP) are located in two separate pump rooms at elevation 1 foot 6 inches in the Turbine Building. The Turbine Buil ding is protected from potential flooding by the flood wall system as shown in Figure 2.5-18 of the FSAR. Access to the first room which houses the two motor driven AFPs is by stairs leading down from the ground floor at elevation 14 feet 6 inches. The enclosure over the pump room stairwell serves as a protective barrier against direct water streams into the Pump Room due to a po ssible overhead pipe failure. The second room which houses the turbine-driven AFP is a vault physically separated from the motor driven AFP room by a reinforced concrete wall. The only access means to this room is through a water-tight fire door.

Separate floor drain and sump systems are provided for each pump room. A high-level alarm system which is monitored in th e Control Room for each sump wi ll indicate exce ssive flooding in the room. The power supply to the sump pump in the moto r driven AFP room and to the 'B' sump pump in the steam-driven AFP room is fed from vital power supply, MCC B61.Directly above each pump and on the ground floor of the Turbine Building is a removable hatch serviced by a monorail and hoist system for equipment removal and emergency access. The AFP and piping in both rooms are Seismic Class I.

The AFPs can each be connected to a separate diesel generator by means of a separate control switch located on the main control board with th e capability to manually start each pump from the control room.

The CST capacity is 250,000 gallons. A nitrogen blan keting system is util ized to limit oxygen intrusion into the stored condensate inventory. A nitrogen sparger sy stem is available to lower the oxygen concentration in the tank.

A redundant relief pr otection scheme, including both breather valves and rupture disks, is provided to prevent an over-pressure or vacuum situation. At operational low level, the volume of water available for decay heat removal and cooldown of the nuclear steam supply system (NSSS) is 165,000 gallons. This is suff icient to cool down the RCS to less than 300

°F following a total loss of offsite power. The 165,000 gallons are also adequate to MPS2 UFSAR10.4-8Rev. 35remove decay heat alone for more than 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br />, leaving a normal no-load water level in the steam generators at the end of 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> afte r initiation of the cooldown cycle. The 165,000 gallons includes unusable tank volume due to discharge nozzle pipe elevation above tank bottom, plus an allowance for vortex formation. CST is equipped with a recirculat ion heating system to prevent freezing within the tank during cold weather. The heating system includes a recirculation line that takes suction inside and near the bottom of the tank, penetr ates the tank above the concrete protected region, is pum ped through a heat exchanger and returns to the top of the tank.

The suction line inside the tank is provided with a siphon breaker to prevent siphoning of the tank following a postulated pipe break.

The siphon breaker is located at a height that will protect the minimum required tank water level to assure suction for the CST he ating system, and to minimize drainage following a postulated pipe rupture.

The CST is missile protected by a concrete wa ll extending to a height which will provide adequate water for a safe shutdown. The exposed por tion of the steel tank is designed to withstand the tornado wind pressure as described in Section 5.7.3.1.4 of the FSAR. Failure in the upper portion of the tank due to missile impact will be local and since the tank is fabricated of ductile steel, any fragmentation is unlikely. However, to ensure proper water flow from the tank in the event of a postulated free falli ng fragment of steel, the tank discharges are protected by screens which will prevent blockage.The portion of the steel liner whic h is protected by the concrete wa ll could be damaged locally by a missile entering through the upper po rtion of the tank. In the event of local damage to the steel tank wall below the top of the exte rior concrete wall, significant wa ter loss is not possible as the steel shell is anchored to the concrete with vertical angles ha ving a spacing of 24 inches. Any minor water leakage will be confined to the interface between the steel and concrete.

The concrete wall, which extends to a height of 25 feet, ensures that a minimum of 205,800 gallons of water is ava ilable for a safe shutdown of the plant. The concrete wall extends above the operational low-water level corresponding to 165,000 gallons.The steam generated during decay heat removal and cooldown during an electric power failure will be discharged by the atmo spheric dump valves (ADV), except for that used by the turbine-driven AFP. The turbine-driven pum p operates reliably as long as th ere is steam pressure in excess of 50 PSIG in one of the steam generators.

The three AFPs are individually controlled from Control Room Panel CO-5 or from the Hot Shutdown Panel C-21 in the Turb ine Building. In addition, the steam-driven AFP can also be controlled from the fire shutdown panel C-10 in the Turbine Bu ilding. The electric-driven pumps may be either automatically ac tuated or manually actuated. Th e steam-driven AFP can only be manually actuated. In the event of a loss of Facility Z2 125 VDC power or a loss of panel DV20, the steam-driven AFP speed adjuster motor and stea m inlet valve can be swapped to Facility Z1 125 VDC power by switching two key-lock ed isolation switches on panel C-05.

For automatic actuation, each pump a nd its associated flow control valve have two switches on each panel. The first switch, the automatic permissi ve, either allows or blocks the a utomatic start of the respective pump. This auto pe rmissive switch has three positions:

MPS2 UFSAR10.4-9Rev. 35*Pull to lock, which blocks the automatic signal.*Reset, which resets the automatic function.*Start, which will start the electric AF Ps and open the flow control valves.

The second switch selects the mode of operation of the flow cont rol valve associated with the pump.

The three modes of selection are:*Normal, which allows the valve to open fully for an automatic actuation.

  • Override, which allows manual control of the valve position following an automatic actuation.*Reset, which resets the electrical logic for returning the mode of operations back to normal.Auto actuation of the electric-driven pumps and the auxiliary feedwater re gulating valves occurs when 3 minutes, 25 seconds ha ve elapsed since the steam generator levels dropped to 26.8 percent.

A manual bypass valve is provided around each air-operated AFW regulating valve, 2-FW-43A and 2-FW-43B, in the auxiliary feedwater (AF) line to each steam generator to ensure the availability of feedwater for decay heat removal should either one of the regulator valves fail in the closed position. To meet the functional requirement of providing AFW to either or both steam generators with a limiting singl e failure, a normally open motor-operated cross-tie valve is provided between the AF regulating valves.In addition, the AFW regulating valves, 2-FW-43A and 2-FW-43B, are equipped with a backup air supply to provide valve closur e and valve control in the event of loss of the Instrument Air System. The backup air supply is pr ovided by high pressure air cyli nders. The system is designed to operate in a harsh environm ent caused by the beyond design basi s event of a feedwater line break inside the turbine building coincident with a failure of the main feedwater check valve (2-FW-5A or 2-FW-5B). The Instrument Air syst em is non-safety rela ted. The backup air supply is safety related.The AFW regulating valves receive an AFAIS signal to open upon low level in either steam generator to ensure feedwater flow following a loss of normal feedwater. These valves are also designed to fail open upon a loss of air or electric power. Follow ing a MSLB or HELB, AFW to the affected steam generator is isolated. The AFW regulating valv es can be closed by the backup air supply for a MSLB inside C ontainment or outside Containment upstream of the Main Steam Isolation Valve (MSIV). For HELBs inside the Turbine Building, the AFW regulating valves are open and the cross-tie motor-operated valve (MOV) is environmentally qu alified to close to isolate the affected steam generator. Depending on which steam generator is affected, the motor MPS2 UFSAR10.4-10Rev. 35 driven pumps may need to be shut down and the turbine-driven pump started to feed the unaffected steam generator. In the event of a single failure in the power system that causes the AFW regulating valve 2-FW-43B to fail open and the MOV cross-tie valve to fail as-is, the affected steam generator will be isolated by local operator action following a MSLB.The auxiliary feedwater system can be used to provide long term cooling in the event of a LOCA in conjunction with the dumping of steam. The AFW pumps would in itially take a suction on the condensate storage tank. If in the long term the CST becomes depleted a nd cannot be replenished by normal makeup, the operators can connect the fire water system and its two, 250,000 gallon storage tanks to the AFW pump suct ions. The fire water storage tanks can be replenished from the city water supply if necessary. See Section 14.6.5.3 for a descripti on of long term cooling in the event of a LOCA. The AFW system contains suction and discharge conne ctions that facilitate portable diesel engine driven AFW pump deployment and CST replenishment. These conditions are defense-in-depth design features that are availabl e for coping with an extended loss of AC power (ELAP) event.

The location of these BDB AFW Flex suction and discharge connections are shown on

Figure 10.4-2, Sheet 3.

10.4.5.4 Equipment 10.4.5.4.1 Condensate Pumps Each condensate pump is a motor driven, multista ge, vertical, canned suc tion type, centrifugal unit. Three 55 percent capacity pum ps are installed at an elevat ion that al lows operation at low level in the condenser hotwell. Table 10.4-1 desc ribes the detail design conditions. The third (standby) pump starts automatically on the low pr essure signal from the condensate discharge header.

10.4.5.4.2 Feedwater HeatersTwo parallel trains with five low pressure heaters and one hi gh pressure heater are provided.

Drain coolers are provided for al l stages of feedwater except Number 3 heater from which the drains are pumped forward, and all except Number 6 heater drain cooler sections are integral with the heaters. All heaters have 439 stainless steel tubes except Numbers 2, 3, and 4 which have 304 series SS. Table 10.4-1 provides more details.

10.4.5.4.3 Heater Drain Pumps Heater drain pumps are motor driven centrifuga l types, vertical, canned suction units. Tw o 55 percent capacity pumps are provided at an elevation that allows adequate NPSH at all loads. Table 10.4-1 lists the details.

MPS2 UFSAR10.4-11Rev. 35 10.4.5.4.4 Steam Generator Feed PumpsEach SGFP is a horizontal turbine-driven centrifugal unit. Two 55 percent capacity pumps operate in series with the condensate pumps. Recircul ation control valves ar e provided in the pump discharge lines to provide automa tic recirculation of a portion of the feedwater flow to the main condenser. This assures that a minimum safe flow is maintained through the pumps. Table 10.4-1 lists the characteristics.

10.4.5.4.5 Steam Generator Feed Pump Turbine Drives Each feedwater pump is driven by an individual steam turbine. The turbine drives are of the dual admission type and are equipped with stop and control valves. Under normal operating conditions, the turbine drives run on the low pressure crossover steam. Main steam is used during plant startup, low load or transi ent conditions when crossover steam is not availa ble or is of insufficient pressure. The turbines operate at 2.5 inches Hg absolute back pressure and exhaust to the main condenser.

10.4.5.4.6 Condensate Polishing Facility When in use, the Condensate Po lishing Facility (CPF) receives condensate from the condenser hotwell after it passes through the Steam Packing Exhauster. After processing, condensate is returned at the air ejectors. The CPF consists of seven parallel flow demineralizers. Full condensate flow can be accomm odated by six demineralizers allowing for regeneration of the seventh without reducing power. The CPF can be completely bypassed. The CPF is used to maintain the secondary system water chemistr y within the limits of plant procedures.

10.4.5.5 Safety Evaluation The components of the condensate and feedwater system are conventional and of a type that has been extensively used in fossil-fueled and other nuclear plants.The plant can carry 65 percent load with one-half of the feedwater heat ers out of service and isolated from the system, with only one condensate pump in opera tion and with only one SGFP in service.

The components of AFWS are designed to the ge neral requirements includi ng seismic response as described in Section 6.1. The components are prot ected from missile dama ge and pipe whip by physical separation of duplicate equipment as described in Section 6.1. The pumps are completely redundant. Each subsystem is capable of providing the requi red amount of feedwater for performing the cold shutdown of the RCS.

The total inventory of the c ondensate and feedwater system is approximately 209,000 gallons divided between the components as follows:1.Condenser (shell) = 80,100 gallons MPS2 UFSAR10.4-12Rev. 352.Condensate and Feedwater piping = 55,500 gallons3.Moisture Separator/Reheater and Drain Ta nks = 3,200 gallons4.Feedwater Heaters = 37,000 gallons 5.Steam Generator = 33,200 gallons The maximum flowrate to each steam generator is approximately 14,100 gpm during normal plant operation.

The potential for failures in the condensate and feedwater syst em are minimized by designing the piping for pressures well above any pressures possible in the system, with the low pressure heaters designed for the maximum shut-off head of the condensate pumps and the high pressure heaters designed for the SGFP shut-off head, see FSAR Section 10.4.5 and Table 10.4-1.

Failures in the condensate system can be readily detected by equi pment performance alarms in the Control Room indicating the malfunction to the operator. The t ype of alarm depends on the severity and location of the failure and allows the operator the option of either isolating the failed component and reducing load or complete shutdown of the plant. However, as with any gross failure in this system, the alarms on the steam generator would ultimately indicate decreased flow, loss of pressure and low liquid level resulting in a possible reactor trip by the reactor protection system (RPS). The type of alarms are dependent on the location of the pipe rupture or equipment failure and are summarized below:1.Failures in the system between the condenser and the condensate pumps would result in gradual flooding of the condenser pit setting off the condenser pit sump high-level alarm, set at 6 inches below the top of the sump. If the condenser hotwell level continues to decrease, a low le vel alarm is registered in the Control Room.2.Failures in the equipmen t or piping between the cond ensate pumps and the SGFPs would result in low condensate pump discharge pressure and low SGFP suction pressure alarms in the Control Room.

In addition, the steam generator would register the alarms indicated previously (i.e., low flow, pressure and liquid level).3.Failures in the equipment or piping between the SGFP discharge and the feedwater containment isolation valves would result in a low pressu re alarm indicated in the feedwater header and low-level alarms for the steam generator

.4.Failures in the piping between the cont ainment isolation valves and the steam generator would be indicated by the low flow, pressure and water level alarms in

the steam generator

.The entire system can be brought to rest, with the termination of all flow, within several seconds from the time the co ndensate and SGFPs are tripped. Static head would be the onl y driving force MPS2 UFSAR10.4-13Rev. 35 for water escaping through leaks at lower elevations. In the even t that the entire system inventory were drained to the Turbine Building ground floor , equipment and floor dr ains located at low spots in the floor would drain the water to the condenser pit sumps and prevent any accumulation on the ground floor. Feedwater pipi ng in the Enclosure Building is either routed through areas void of essential equipment or provided with restraints in other areas as required so that any ruptures occurring do not af fect safe operation of the plant. Ther efore, any postulated failures in the condensate and feedwater system can be detected and controlled quickly, and in no way affect the operation of essential equipment.To increase the original design basis safety margin for a main stream line break (MSLB) inside containment, the MSI signal was modified to actua te on either high containment pressure or low steam generator pressure. The m odified MSI signal provides a mo re rapid isolation signal for feedwater and main steam isolat ion during a steam line break within containment. Also, the feedwater block valves, feedpump discharge valv es, feedwater regulating and bypass valves as well as the feed pumps are pr ovided with redundant MSI trip a nd closure signals for ensuring feedwater isolation.

10.4.5.6 Tests and Inspection Equipment, instruments, and controls are regularly inspected to ensure proper functioning of systems. The motor driven pumps and controls are given preoperational tests after erection and before plant warmup.

The AFWS can be tested during normal operation by reci rculating an AFP flow of 50 gpm to the CST.

10.4.6 STEAM GENERATOR BLOWDOWN SYSTEM 10.4.6.1 Design Bases The function of the steam genera tor blowdown system (SGBS) is to withdraw and reject the system fluid at a rate which will maintain contaminate concentrations in the steam generator water below equipment operating limits. The sy stem has three modes of operation: sampling blowdown: condenser leakag e: and startup blowdown.

10.4.6.2 System DescriptionThe SGBS is shown in Figure 10.3-1. Blowdow n and quench tanks are provided. The blowdown tank has a capacity of two percen t of the vwo main steam flow and is used du ring startup and when condenser tube leakage occurs. The quenc h tank has a blowdown ca pacity of 10 gpm and will normally be in service at all times when the blow down tank is not in service.

T ube sheet blowdown nozzles are provided on each steam generator. The blowdown tank vents to the atmosphere and the quench tank vents to the gas processing system. Normally, both drain to the condenser cooling water discharge. The quenc h tank is provided with a closed recirculating pump and cooler cycle for quench water supply.

MPS2 UFSAR10.4-14Rev. 35The steam generator blowdown is automatically isolated in response to the CIAS and the low-low steam generator water level trip (AFAIS) that activates the auxiliary feedwater system.A radioactivity monitor is located in the co mbined sampling line from both steam generator blowdown lines. When a high ra dioactivity level is detected, an alarm is annunciated in the Control Room and the blowdown stop and drain valves are closed automatically. The blowdown system residual inventory is ma nually diverted to the Aerated Liquid radioactive waste system.

The 10 gpm quench tank blowdown ma y be resumed; if so, the blow down liquid is diverted to the Clean Liquid radioactive waste system.

10.4.6.3 Safety Evaluation Failure analysis of system components is given on Ta ble 10.4-2.

10.4.6.4 Tests and InspectionThe steam generator blowdown tank and quench tank are designed in accordance with ASME Section VIII and seismi c Class II require ments. The performance of th e blowdown system is ascertained by an inplace test.

10.

4.7 REFERENCES

10.4-1"Millstone Unit Number 2 FSAR Chapter 10 Loss of Normal Feedwater Flow Transient with Reduced Auxiliary Feedwater Flow," EMF-98-049, Rev. 0, Siemens Power Corporation, August 1998.

MPS2 UFSARMPS2 UFSAR10.4-15Rev. 35TABLE 10.4-1 MAJOR COMPON ENTS OF THE CONDENSATE AND FEEDWATER SYSTEM Steam Generator Feed Pumps TypeDouble suction, diffuser type, single stage, vertical split, horizontal centrifugalQuantity2Capacity each (gpm)15,000 Head differential tdh (feet)2,100 MaterialCaseASTM A217, Gr C5ImpellerASTM A296, Gr CA 15ShaftAISI 410 Ht & SRDriverCondensing, nonextrac ting, dual admission, horizontal steam turbineCodesASME Section VIII and IX, Standards of the Hydraulic Institutes, NEMA, ANSIManufacturerIngersoll RandSteam Generator Auxiliary Feed PumpsTypeHorizontal, split case , multistage, centrifugal Quantity1 turbine driven, 2 motor drivenCapacity each (gpm)600300 Head (feet)24372437 MaterialCaseASTM A 216, Gr WCB ImpellerASTM A 48, Class 30 for P9B; ASTM A 217, Grade CA15 for P9A, P4 ShaftASTM A 582, Type 416 or ASTM A 276 Type 410 DriverSingle-state, noncondensing steam turbine (for turbine-driven) GE motor, 350 Hp, 4160 volt, 60 Hz, 3 phase, 3600 rpm (for motor-driven pumps)

MPS2 UFSARMPS2 UFSAR10.4-16Rev. 35Seismic requirements CodesClass IASME Code for Pumps and Valves for Nuclear Power, Class II NEMA Sta ndard SM 20-1958 Hydraulic InstituteManufacturerIngersoll RandCondensate PumpsTypeVertical centrifugalQuantity3Capacity each (gpm)9200 Head (ft)1050 MaterialCaseASTM A-48, CL 30ImpellerASTM A-296, Gr CA-15ShaftASTM A-276, Type 416DriverE1 motor, 3000 Hp 6600 volts, 60 Hz, 3 phase, 900 rpmCodesASME Sections VIII and IX, Standards of the Hydraulic Institute, NEMA ANSIManufacturerB&W Canada Heater Drain PumpsTypeVertical CentrifugalQuantity2 (per unit)Capacity each (gpm)4300 Heat (feet)1000 MaterialCaseASTM A-217, Gr C-5TABLE 10.4-1 MAJOR COMPONENTS OF THE CONDENSATE AND F EEDWATER SYSTEM (CONTINUED)

MPS2 UFSARMPS2 UFSAR10.4-17Rev. 35 ImpellerASTM A-296, Gr. CA-15 ShaftASTM A-276, Type 410 HT Driver E1 motor 1250 Hp, service fact or 1.15 4160 volts, 60 Hz, 3 phase, 1800 rpm CodesASME Sections VIII and IX, Standards of the Hydraulic Institute, NEMA, ANSI Manufacturer Byron-JacksonCondenserTypeTwo shell, single-pass with di vided water boxes, surface condenser Design duty (Btu/hr) 6.059 x 10 9Heat transfer area (ft 2)485,260 totalDesign pressureShell 29.5 in. Hg. vacuum Water box 25 psig MaterialShellASTM A-285, Grade CTubesASTM B 338, Gr. 2 TitaniumTube sheetsASTM B-265, Gr. 2 TitaniumCodesStandards of the Heat Exchange InstituteFeedwater HeatersTypeClosed, U-tube except drain cooler is straight MaterialHeater 1 (A,B)Heater 2 (A,B)Heaters 3 & 4 (A, B)OthersShellCarbon steelCarbon steelCarbon steelCarbon steel Tubes439 SS304 LSS Stainless Steel439 SS Tube SheetsCarbon Steel w/Inconel overlayCarbon SteelCarbon SteelCarbon SteelCodesASME Section VIII, Heat Exchange InstituteTABLE 10.4-1 MAJOR COMPONENTS OF THE CONDENSATE AND F EEDWATER SYSTEM (CONTINUED)

MPS2 UFSARMPS2 UFSAR10.4-18Rev. 35 Details on joints, tube-to-tube sheetsWelded & RolledHydraulically Expanded & RolledRolledRolled Heater No.

Design Duty Each (Btu/

hr)Design Pressure (psig)Design Temperature

(°F)Heat Transfer Area Each (ft 2)ShellTubeShellTube 1, A, B 355.215 x 10 6 450170046046020,445 2, A, B 287.518 x 10 6 225 65040040023,675 3, A, B 154.152 x 10 630 in Hg. & 150 65037037012,163 4, A, B 296.046 x 10 630 in. Hg & 75 65033033017,019 5, A, B 263.347 x 10 630 in. Hg & 50 65030030016,144 6, A, B 198.156 x 10 630 in. Hg & 50 65030030015,839 Drain cooler (6, A, B) 47.550 x 10 630 in. Hg 650300300 5,156 PipingTABLE 10.4-1 MAJOR COMPONENTS OF THE CONDENSATE AND F EEDWATER SYSTEM (CONTINUED)

MPS2 UFSARMPS2 UFSAR10.4-19Rev. 35 Piping SystemApplicable CodeMaterialDesign Pressure (psig)Design Temperature

°F Main steamANSI B31.1.0ASTM A-144 Gr. KC 70 1000 580 Main steam penetration piping (including atmospheric dump)ANSI B31.7 C12ASTM A-155 Gr. KC 70 1000 580 FeedwaterANSI B31.1.0ASTM A-106 Gr. C 1600 400-450ANSI B31.1.0ASTM A-106 Gr. B 1100 600ANSI B31.1.0ASTM A-335 Gr. P5 1100-1600 400-600ANSI B31.1.0ASTM A-335 Gr. P22 1100-1600 400-600 Feedwater penetrationANSI B31.7CL 2ASTM A-106 Gr. B 1100 600ANSI B31.7CL 2ASTM A-335 Gr. P5 1100 600ANSI B31.7CL 2ASTM A-335 Gr. P22 1100 600 CondensateANSI B31.1.0ASTM A-106 Gr. B or ASTM A-335 Gr. P22 650 400 MPS2 UFSARMPS2 UFSAR10.4-20Rev. 35TABLE 10.4-2 FAILURE ANALYSIS OF STEAM GENERATOR BLOWDOWN SYSTEM COMPONENTS1.Steam Generator Blowdown line Break at 2 inch diameter line inside containment1)Containment pressure and Radiation

monitoring.Plant shutdownRadioactivity release only to the containment which can be held and

processed through filters.2)Containment sample loss alarm2.Steam Generator Blowdown pipinga) Outside the containment1)Area radiation monitoring Close control valve HV4246 & HV4248 or Plant shutdownRadioactivity release to the Auxiliary Building is monitored as discharged to the environment

through the EBFS and liquid collected in the Drain System.

b) Break of Blowdown

piping downstream valve HV4246 or 4248 in the

Enclosure Building2)Aerated waste sump level alarms. 3.Radiation Monitors Radiation monitoring failure with no mechanical

piping failure Radiation monitoring

failure alarm at control

room. Close control valves

HV4246, HV4248, HV4245, and HV4578 and manual sampling MPS2 UFSAR10.4-21Rev. 35FIGURE 10.4-1 P&ID CONDENSER AIR REMOVAL WATER BOX PRIMING AND TURBINE BUILDING SUMP (25203-26012)

The figure indicated above represents an engineering controlled drawing that is Incorporated by Reference in the MPS-2 FSAR. Refer to the List of Effective Figures for the related drawing number and the controlled plant drawing for the latest revision.

MPS2 UFSAR10.4-22Rev. 35FIGURE 10.4-2 P&ID CONDENSATE SYSTEM (25203-26005 SHEET 1)

The figure indicated above represents an engineering controlled drawing that is Incorporated by Reference in the MPS-2 FSAR. Refer to the List of Effective Figures for the related drawing number and the controlled plant drawing for the latest revision.

MPS2 UFSAR10.4-23Rev. 35FIGURE 10.4-2 P&ID CONDENSATE SYSTEM (25203-26005 SHEET 2)

The figure indicated above represents an engineering controlled drawing that is Incorporated by Reference in the MPS-2 FSAR. Refer to the List of Effective Figures for the related drawing number and the controlled plant drawing for the latest revision.

MPS2 UFSAR10.4-24Rev. 35FIGURE 10.4-2 P&ID CONDENSATE ST ORAGE AND AUXILIARY FEED (25203-26005 SHEET 3)

The figure indicated above represents an engineering controlled drawing that is Incorporated by Reference in the MPS-2 FSAR. Refer to the List of Effective Figures for the related drawing number and the controlled plant drawing for the latest revision.

MPS2 UFSAR10.4-25Rev. 35FIGURE 10.4-2 P&ID CONDENSATE ST ORAGE AND AUXILIARY FEED (25203-26005 SHEET 4)

The figure indicated above represents an engineering controlled drawing that is Incorporated by Reference in the MPS-2 FSAR. Refer to the List of Effective Figures for the related drawing number and the controlled plant drawing for the latest revision.