NIS-1 OWNER'RATA REPORT FOR INSERVICE lsPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner Public Service Electric & Gas Co .. 80 Park Plaza. Newark. NJ. 07101 2.

  • Plant Salem Generating Station P.O. Box E. Hancock's Bridge. NJ 08038 3. Plant Unit Unit 1 (Facility Operating License DPR-70) 4. Owner's Certificate of Authorization (if Required)

NIA 5. Commercial Service Date 07101/77 6. National Board Number for Unit 20757 7. Components inspected (see page 1) 8. Exam Dates March 7. 1995 to March 17. 1998 9. Inspection Interval from February 27. 1988 to July 7. 2001 10. Applicable Edition of ASME Section XI, 1983, through 1983 Summer Addenda 11. Abstract of Examinations:

Component or Appurtenance

  1. 11 Steam Generator
  1. 12 Steam Generator
  1. 13 Steam Generator
  1. 14 Steam Generator Reactor Coolant System Safety Injection System Residual Heat Removal System Boiler Feed System Main Steam System Chemical Volume and Control System Auxiliary Feedwater System Containment Spray System Service Water System Component Cooling System Sampling System Manufacturer or Installer Westinghouse Tampa Div. P.O. Box 19218 Tampa, FL 33616 " " " " United Engineers

& Constructors (UE&C) UE&C UE&C UE&C UE&C UE&C UE&C UE&C UE&C UE&C Manufacturer or Installer Serial No. 2174 2173 2171 2172 NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA 9807220295 980713 PDR ADOCK 05000272 ---...,, I Page 1 Q . ____ __ I State or Province No. NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA National Board No. NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA

  • , .... ,, ;ORM NIS-1 REPORT FOR INSERVICE IPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Ownyr Public Service Electric & Gas Co., 80 Park Plaza, Newark. NJ. 07101 2. Plant Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 3. Plant Unit Unit 1 (Facility Operating License DPR-70) 4. Owner's Certificate of Authorization (if Required)

NIA 5. Commercial Service Date 07/01/77 6. National Board Number for Unit 20757 7. Components inspected (see page 1) 8. Exam Dates March 7, 1995 to March 17, 1998 9. Inspection Interval from February 27. 1988 to July 7, 2001 10. Applicable Edition of ASME Section XI, 1983, through 1983 Summer Addenda 11. Abstract of Examinations:

An inservice examination (ISI) of selected Class 1, Class 2 and Class 3 components of Public Service Electric and Gas Company's (PSE&G) Salem Generating Station, Unit 1, was performed by Public Service Electric & Gas* (PSE&G), Magnaflux Quality Services (MQS), Southwest Research Institute (SwRI), Virginia Corporation of Richmond (VCR) and AEA Technology Engineering Services (AEA) personnel during the April 1995 -April 1998. These examinations constituted the twelfth (2nd Period, 3rd Outage) at Salem 1 during the Second 10-year Inspection Interval of operation.

Exams were performed in accordance with the 1983 Edition through Summer 1983 Addenda of ASME Section XI and the Salem Inservice Inspection Program Long Term Plan. ISI was performed utilizing visual (VT), magnetic particle (MT), liquid penetrant (PT), manual ultrasonic (UT), mechanized ultrasonic (M-UT) and radiography (RT) nondestructive examination techniques.

This report also contains augmented examinations required by the Salem Technical Specifications, Regulatory Guides, Circulars and Bulletins issued by the United States Nuclear Regulatory Commission.

Page 2

..

NIS-1 OWNER'RATA REPORT FOR INSERVICE .PECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1.

Public Service Electric & Gas Co .. 80 Park Plaza. Newark. NJ, 07101 2. Plant Salem Generating Station P.O. Box E. Hancock's Bridge, NJ 08038 3. Plant Unit Unit 1 (Facility Operating License DPR-70) 4. Owner's Certificate of Authorization (if Required)

NIA 5. Commercial Service Date 07/01/77 6. National Board Number for Unit 20757 7. Components inspected (see page 1) 8. Exam Dates March 7, 1995 to March 17. 1998 9. Inspection Interval from February 27, 1988 to July 7, 2001 10. Applicable Edition of ASME Section XI, 1983, through 1983 Summer Addenda 11. Abstract of Examinations:

11.1 MQS, SwRI and VCR under the direction of the PSE&G ISI Group, conducted 13 manual ultrasonic, five liquid penetrant and two magnetic particle examinations.

There were no unacceptable indications identified.

Class 1 => Vessels => Steam Generator

=> Piping => Reactor Coolant => Safety Injection

=> Residual Heat Removal Class 2 => Vessels => Steam Generator

=> Piping => Boiler Feed => Main Steam => Chemical Volume Control Page 3

. ,.

NIS-1 OWNER'"ATA REPORT FOR INSERVICE lsPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1.

Public Service Electric & Gas Co .. 80 Park Plaza. Newark. NJ. 07101 2. Plant Salem Generating Station P.O. Box E. Hancock's Bridge. NJ 08038 3. Plant Unit Unit 1 (Facility Operating License DPR-70) 4. Owner's Certificate of Authorization (if Required)

N/ A 5. Commercial Service Date 07/01/77 6. National Board Number for Unit 20757 7. Components inspected (see page 1) 8. Exam Dates March 7. 1995 to March 17. 1998 9. Inspection Interval from February 27. 1988 to July 7. 2001 10. Applicable Edition of ASME Section XI, 1983, through 1983 Summer Addenda 11. Abstract of Examinations:

11.2 ISI Section XI Visual examinations on valves and bolting PSE&G's ISI Group conducted eight Class 1 bolting exams and one Class 1 valve internal exam. ISI Section XI examinations were conducted on the following systems: => Safety Injection

=> Residual Heat Removal The following was identified during the course of these examinations:

Valve 1RH26 (WinISI Sum# 193800) had a visual VT-3 internal examination, which revealed seating surface wear. The valve interior was resurfaced and an acceptable post rework VT-3 valve internal examination was performed.

An additional sample was not required, since the valve is the only one identified in that valve group. There were no other unacceptable indications identified.

11. 3 ISl Section XI Visual examination of components supports PSE&G conducted four Class 1, 2 & 3 component support visual VT-3 and VT-3/ 4 examinations.

ISI Section XI examinations were conducted on the following systems: => Main Steam => Safety Injection

=> Reactor Coolant => Chemical and Volume Control There were no unacceptable indications identified.

Page 4

. -

NIS-1 OWNER'AATA REPORT FOR INSERVICE lsPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1.

Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ. 07101 2. Plant Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 3. Plant Unit Unit 1 (Facility Operating License DPR-70) 4. Owner's Certificate of Authorization (if Required)

NIA 5. Commercial Service Date 07/01/77 6. National Board Number for Unit 20757 7. Components inspected (see page 1) 8. Exam Dates March 7, 1995 to March 17. 1998 9. Inspection Interval from February 27. 1988 to July 7, 2001 10. Applicable Edition of ASME Section XI, 1983, through 1983 Summer Addenda 11. Abstract of Examinations:

11.4 ISI Section XI System Leakage Examinations PSE&G' s ISI Group conducted four System Pressure Tests during a System Functional or Inservice Test, on Nuclear Class 1, 2 and 3, in accordance with ASME Section XL A system Leakage exam was performed in accordance with ASME Section XI on all Class 1 Systems. The system leakage test was performed with the Reactor Coolant System in Mode 3 (normal operating temperature and pressure) with the insulation installed.

No pressure boundary leakage was detected.

Work requests were initiated to correct minor mechanical leakage that was not corrected during the system walkdowns.

Class 2 and 3 System Pressure Tests were conducted on the following systems: :::::> Auxiliary Feedwater

> Sampling 11.5 RCP Flywheel Augmented Examinations per USNRC Regulatory Guide 1.14 SwRI under the direction of the ISI Group performed a Ten year exam (with the Flywheels removed from the motors) on all Salem Unit 1 & 2's RCP Flywheels at the Westinghouse Cheswick, PA facility as identified below by the Flywheel serial number: 2S-76P917 3S-75P790 4S-75P790 3S-76P917 1S-88P318 2S-75P790 1S-75P790 1S-D003 1S-76P917 There were no unacceptable indications identified.

Page 5

. '

NIS-1 OWNER'"ATA REPORT FOR INSERVICE .PECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1.

Public Service Electric & Gas Co., 80 Park Plaza. Newark. NJ. 07101 2. Plant Salem Generating Station P.O. Box E, Hancock's Bridge. NJ 08038 3. Plant Unit Unit 1 (Facility Operating License DPR-70) 4. Owner's Certificate of Authorization (if Required)

NI A 5. Commercial Service Date 07/01/77 6. National Board Number for Unit 20757 7. Components inspected (see page 1) 8. Exam Dates March 7, 1995 to March 17. 1998 9. Inspection Interval from Februar:y

27. 1988 to July 7. 2001 10. Applicable Edition of ASME Section XI, 1983, through 1983 Summer Addenda 11. Abstract of Examinations:

11.6 NRC Bulletin 88-08 "Thermal Stresses in Piping Connected to the Reactor Coolant System" Augmented Examinations VCR under the direction of PSE&G's ISi Group performed augmented ultrasonic and dye penetrant examinations on a total of 20 components, broken down as follows: => 15 -1.5 inch Safety Injection piping welds => Two -2 inch Chemical and Volume Control piping welds => Two -3 inch Chemical and Volume Control piping welds There are no unacceptable indications identified.

11.7 Augmented Exams per Branch Technical Position MEB 3-1 30 welds were volumetrically examined, to comply with the augmented requirements of NUREG 0800 Standard Review Plan, Section 3.6.2, Branch Technical Position MEB 3-1. The UT was performed by VCR with no unacceptable indications identified.

11. 8 NRC Bulletin 88-11 "Pressurizer Surge Line Thermal Stratification" Augmented Examinations PSE&G's ISi Group performed visual examinations on all existing surge line pipe supports I HEBA restraints and their associated insulation interfaces.

A total of ten supports were examined.

There were no unacceptable indications identified.

Page 6

NIS-1 REPORT FOR INSERVICE .PECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1.

Public Service Electric & Gas Co .. 80 Park Plaza. Newark. NJ. 07101 2. Plant Salem Generating Station P.O. Box E. Hancock's Bridge. NJ 08038 3. Plant Unit Unit 1 (Facility Operating License DPR-70) 4. Owner's Certificate of Authorization (if Required)

NI A 5. Commercial Service Date 07/01177 6. National Board Number for Unit 20757 7. Components inspected (see page 1) 8. Exam Dates March 7. 1995 to March 17. 1998 9. Inspection Interval from February 27. 1988 to July 7. 2001 10. Applicable Edition of ASME Section XI, 1983, through 1983 Summer Addenda 11. Abstract of Examinations:

11.9 Augmented System Leakage tests per NUREG 0578 "TMI Lessons Learned" PSE&G's ISI Group conducted 27 System Leakage Tests in accordance with NUREG 0578 on the following systems: Safety Injection Chemical and Volume Control Sampling Waste Gas Residual Heat Removal Containment Spray Liquid Radwaste Waste Liquid There were no unacceptable indications identified.

11.10 PSE&G's Supplemental Ultrasonic Examinations on the old Steam Generator Feedwater Nozzle to Forging Expanders AEA ultrasonically examined the four Steam Generator Feedwater Nozzle inner radius and the barrel of the nozzle including the Feedwater thermal sleeves. There were no unacceptable indications identified.

11.11 PSE&G Augmented Visual Examinations on the Reactor Coolant Pump Main Flange connection (R/T# 290049) PSE&G's ISI Group performed a visual examination of the Reactor Coolant Pumps Main Flange connection for evidence of leakage in accordance with R/T# 290049. Each of the four RCP' s showed evidence of RCS leakage (dried boron on the main flange connection area and the bolting).

All the RCP main flange studs were removed, several at a time, and visually VT-1 examined for damage and reinstalled and re-torqued.

Several studs were found with unacceptable conditions and were replaced as required (See the following preservice examination descriptions for specific details) Page 7

NIS-1 OWNER'IATA REPORT FOR INSERVICE .PECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner Public Service Electric & Gas Co .. 80 Park Plaza. Newark. NJ. 07101 2. Plant Salem Generating Station P.O. Box E. Hancock's Bridge. NJ 08038 3. Plant Unit Unit 1 (Facility Operating License DPR-70) 4. Owner's Certificate of Authorization (if Required)

NI A 5. Commercial Service Date 07101/77 6. National Board Number for Unit 20757 7. Components inspected (see page 1) 8. Exam Dates March 7. 1995 to March 17. 1998 9. Inspection Interval from February 27. 1988 to July 7. 2001 10. Applicable Edition of ASME Section XI, 1983, through 1983 Summer Addenda 11. Abstract of Examinations:

11.12 Preservice Examinations on Various Bolting Material Replacements Several bolted connections were replaced as identified below: ITEM PSE&G PSE&G PSE&G COMPONENT NO. DCPNO. CJPNO. W.0.# DESCRIPTION

1. NIA S-93-036 920804179 Valve lPRl Bonnet Bolting 2. NIA S-94-048 950527023 Valve 1PR4 Flange Bolting 3. NIA S-94-052 940425148 Valve 1PR5 Flange Bolting 4. NIA S-94-051 940425145 Valve 1PR3 Flange Bolting 5. NIA S-94-073 940520130 Valve 1PR3 Flange Bolting 6. NIA S-95-288 950325019 Valve 13MS167 7. NIA S-95-287 950325019 Valve 1CV78 8. NIA S-95-254 950527006 Valve 1CV80 9. NIA S-95-180 950505099 Valve 1CV75 10. NIA S-95-176 950520006 Valve 1SJ150 11. NIA S-95-026 941112125 Valve 1CV75 12. NIA S-96-072 950811370 13 RCP Main Flange 13. NIA S-96-071 950811362 11 RCP Main Flange 14. NIA S-96-062 950811372 14 RCP Main Flange 15. NIA S-96-059 950811368 12 RCP Main Flange 16. NIA S-97-031 960921041 Valve 14MS167 17. NIA S-97-077 960921040 Valve 12MS167 18. NIA S-97-232 950527035 Valve 1PR3 Inlet Flange 19. NIA S-97-233 951104046 Valve 1PR4 Inlet Flange 20. NIA S-97-234 950608024 Valve 1PR5 Inlet Flange 21. NIA S-97-263 971107115 Valve 2PS25 22. NIA NIA NIA Valve 1PR3, 4, & 5 (P.O.# P3-0933105-0630)
23. NIA S-97-263 971107115 Valve 2PS25 The applicable (PSI) examinations were performed with no unacceptable indications identified.

Page 8

NIS-1 OWNER'IATA REPORT FOR INSERVICE .PECTIONS AS REQUJRED BY THE PROVISIONS OF THE ASME CODE RULES 1.

Public Service Electric & Gas Co .. 80 Park Plaza, Newark. NJ, 07101 2. Plant Salem Generating Station P.O. Box E. Hancock's Bridge, NJ 08038 3. Piant Unit Unit 1 (Facility Operating License DPR-70) 4. Owner's Certificate of Authorization (if Required)

NIA 5. Commercial Service Date 07/01/77 6. National Board Number for Unit 20757 7. Components inspected (see page 1) 8. Exam Dates March 7, 1995 to March 17. 1998 9. Inspection Interval from February 27. 1988 to July 7. 2001 10. Applicable Edition of ASME Section XI, 1983, through 1983 Summer Addenda 11. Abstract of Examinations:

11.13 Preservice Examinations on Various Component Supports and their Associated Integral Attachments due to Repair/Replacement/Modifications Several component supports and their associated integral attachments were repaired/replaced or modified as identified below: ITEM PSE&G PSE&G PSE&G COMPONENT NO. DCPNO. CJPNO. W.0.# DESCRIPTION

1. lEC-3323-2 PS-94-036 940811077 MSWG-30 2. lEC-3323-3 PS-95-033 950913228 Sl-SWPG-49
3. lEC-3396-4 PS-95-070 951114131 Various Aux. Feedwater supports 4. lEC-3412-1 PS-95-037 950823379 Various PZR Relief supports 5. NIA S-95-210 950809300 MSWG-36A 6. NIA S-95-171 950803107 MSWG-25 7. lEC-3396-1 PS-95-028 950606218 Various SJ, RHR, & CS supports 8. NIA S-95-105 950519222 13-FWLS-11
9. NIA S-95-040 950215277 lM-SWPS-029
10. lEE-0102 PS-95-012 950206127 lC-PRH-155
11. lEC-3322-1 PS-95-033 940811073 Various Service Water supports 12. lEC-3323-1 PS-94-035 950914127 Various Service Water supports 13. lEC-3404-1 PS-95-010 950206095 1-PRG-2552
14. lEC-3322-4 PS-95-035 940811075 Various Service Water supports 15. lEC-3322-2 PS-94-034 940811076 Various Service Water supports 16. lEC-3323-3 PS-95-032 950913288 Various Service Water supports 17. lEC-3323-3 PS-95-050 950914129 Various Service Water supports 18. lEC-3476-1 PS-95-078 951001130 1C-13SIH-136

& lC-llSIA-39

19. lEE-0282-1 PS-96-142 960523251 Various Service Water supports 20. lEC-3525-1 PS-96-001 951212220 Various CVCS supports 21. lEC-3668-8 PS-97-070 970318111 lP-1 lSWG-005 & lP-1 lSWS-2 22. lEC-3668-9 PS-97-071 970318121 Various Service Water supports Page 9

...

NIS-1 REPORT FOR INSERVICE .PECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Ownyr Public Service Electric & Gas Co .. 80 Park Plaza. Newark. NJ. 07101 2. Plant Salem Generating Station P.O. Box E. Hancock's Bridge. NJ 08038 3. Plant Unit Unit 1 (Facility Operating License DPR-70) 4. Owner's Certificate of Authorization (if Required)

NI A 5. Commercial Service Date 07101/77 6. National Board Number for Unit 20757 7. Components inspected (see page 1) 8. Exam Dates March 7. 1995 to March 17. 1998 9. Inspection Interval from February 27. 1988 to July 7. 2001 10. Applicable Edition of ASME Section XI, 1983, through 1983 Summer Addenda 11. Abstract of Examinations:

ITEM PSE&G PSE&G PSE&G NO. DCP NO. CJP NO. W.0.# 23. lEC-3668-3 PS-97-085 970318099

24. lE0-2600-1 PS-97-039 961011186
25. lEC-3668-4 PS-97-090 970318103
26. lEC-2668-15 PS-97-092 970318133
27. lEC-3715-3 PS-97-125 970815174
28. lEC-3668-5 PS-97-091 970318104
29. lEC-3668-3 PS-97-084 970318099
30. lEC-3715-2 PS-97-116 970818173
31. lEC-3668-7 PS-97-129 970318108
32. lEA-1240-1 PS-98-001 970620208
33. lEA-1240-1 PS-98-002 970525116 970525067
34. lEA-1240-1 PS-98-003 970526071 970526068
35. lEC-3343-1 PS-97-049 950218096 PS-97-050 950609102 PS-97-051 PS-97-052
36. NIA S-94-074 940426177
37. NIA S-94-049 940413245

940424126

38. NIA S-97-224 970811072
39. NIA S-95-161 950523016
40. NIA S-95-220 950523016
41. NIA S-95-157 950523016
42. NIA S-95-159 950523016
43. NIA S-95-248 950523016
44. NIA S-95-221 950523016 Page 10 COMPONENT DESCRIPTION Various SW (CFCU) supports lCCH-8 Various SW (CFCU) supports 1C-13SWG-3A

& 3B Various CVCS supports Various SW (CFCU) supports Various SW (CFCU) supports Various CS supports Various SW (CFCU) supports FWH-14-24 FWG-11-3065

& FWG-12-3066 Various SIG Feedwater supports SIG platform to SIG lower vertical support attachment welds 1A-CVCH-408A and 1A-CVCH-407A lC-PRH-145 and lC-PRH-149 1PRSN29 lC-PRSN-401 lC-CC-SNOOl lA-CC-SNlOOB 1C-CVCSN900 lC-SISN-501 lC-PRSN-023

NIS-1 REPORT FOR INSERVICE IPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1.

Public Service Electric & Gas Co .. 80 Park Plaza, Newark. NJ. 07101 2. Plant Salem Generating Station P.O. Box E. Hancock's Bridge. NJ 08038 3. Plant Unit Unit 1 (Facility Operating License DPR-70) 4. Owner's Certificate of Authorization (if Required)

NI A 5. Commercial Service Date 07/01/77 6. National Board Number for Unit 20757 7. Components inspected (see page 1) 8. Exam Dates March 7, 1995 to March 17. 1998 9. Inspection Interval from February 27. 1988 to July 7. 2001 10. Applicable Edition of ASME Section XI, 1983, through 1983 Summer Addenda 11. Abstract of Examinations:

11.14 ITEM PSE&G PSE&G PSE&G COMPONENT NO. DCP NO. CJP NO. W.0.# DESCRIPTION

45. NIA 46. NIA 47. NIA 48. NIA S-95-158 S-97-239 S-95-160 S-95-195 950523016 950815548 950523016 950523016 lA-SISN-lOlA lC-SISN-500 1A-MSASN-147A lA-MSASN-147 A The applicable (PSI) examinations were performed with no unacceptable indications identified.

Preservice Examinations on Various Piping welds due to Repair/Replacement/Modifications Several piping welds were repaired/replaced or modified as identified below: ITEM PSE&G PSE&G PSE&G COMPONENT NO. DCPNO. CJPNO. W.0.# DESCRIPTION

1. NIA S-95-292 931002072 l 1SJ139 associated piping welds 2. NIA S-95-349 950623083 11 RHR Pump piping replacement
3. lEE-0152-1 PS-95-093 951120163 Valve 1CV55 replacement welds 4. lEC-3530 PS-96-029 960116178 Safety Injection System orifice addition, socket welds 5. NIA S-96-084 960111096 Valve 13SJ143 replacement welds 6. NIA S-96-398 960506124 Valve 1 lRHlO replacement welds 7. lEC-3525-1 PS-96-001 951212220 Valves 1CV63 & 1CV141 relocation associated welds Page 11

NIS-1 OWNER'RATA REPORT FOR INSERVICE lsPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1.

Public Service Electric & Gas Co .. 80 Park Plaza, Newark, NJ, 07101 2. Plant Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 3. Plant Unit Unit 1 (Facility Operating License DPR-70) 4. Owner's Certificate of Authorization (if Required)

NI A 5. Commercial Service Date 07/01/77 6. National Board Number for Unit 20757 7. Components inspected (see page 1) 8. Exam Dates March 7, 1995 to March 17, 1998 9. Inspection Interval from February 27, 1988 to July 7, 2001 10. Applicable Edition of ASME Section XI, 1983, through 1983 Summer Addenda 11. Abstract of Examinations:

ITEM PSE&G NO. DCPNO. PSE&G CJPNO. PSE&G W.0.# 8. 9. NIA S-96-049 951004102 lEC-3530-2 PS-97-029 970623168 COMPONENT DESCRIPTION Valve 1CV137 associated welds Safety Injection System orifice addition, socket welds near valves 11-14SJ16 The applicable (PSI) examinations were performed with no unacceptable indications identified.

11.15 Preservice Examinations per, DCP# MM-97-099, CJP# S-97-156, Work Order# 970613277 Replacement of the 11 Charging Pump Casing (1 CVE20). The applicable (PSI) examinations were performed with no unacceptable indications identified.

11.16 Preservice Examinations per, CJP# S-97-257, Work Order# 971108157 Weld repairs to the 100' personnel airlock door seal knife edges. The (PSI) examinations were performed with no unacceptable indications identified.

11.17 Preservice Examinations per, Work Order# 971129120 The 100' personnel airlock inside and outside door (inner and outer) rubber 0-ring seal replacement.

The (PSI) examinations were performed with no unacceptable indications identified.

Page 12

NIS-1 REPORT FOR INSERVICE IPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1. Owner Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ, 07101 2. Plant Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 3. Plant Unit Unit 1 (Facility Operating License DPR-70) 4. Owner's Certificate of Authorization (if Required)

N/ A 5. Commercial Service Date 07/01/77 6. National Board Number for Unit 20757 7. Components inspected (see page 1) 8. Exam Dates March 7, 1995 to March 17, 1998 9. Inspection Interval from February 27, 1988 to July 7, 2001 10. Applicable Edition of ASME Section XI, 1983, through 1983 Summer Addenda 11. Abstract of Examinations:

11.18 Preservice Examinations on four Replacement Steam Generators and their Associated Feedwater, Main Steam and Reactor Coolant piping welds and component supports I integral attachments The Steam Generator Vessel welds, Steam Generator Primary Manway bolting, Reactor Coolant, Feedwater, and Main Steam piping welds and their associated component supports/integral attachments were replaced/repaired and/or modified as identified below: ITEM PSE&G PSE&G REPAIR/REPLACEMENT/

NO. DCPNO. P.O. NO .. MODIFICATION DESCRIPTION

1. NIA P3-0879959
  1. 11 -14 Steam Generator (S/G) vessel welds were preservice (PSI) examined at the Sea Brook Facility by SwRI after the construction hydro was satisfactorily completed.
2. EWP# NIA #11 -14 new Steam Generators Primary SLM-MOD-04 Manway bolts were replaced with studs and nuts. 3. EWP# NIA #11 -14 new Steam Generator Reactor SLM-MOD-07 Coolant hot and cold leg tie in welds. 4. lEA-1240-11 NIA #11 SIG Feedwater piping and component support/integral attachment modifications.
5. lEA-1240-12 NIA #12 SIG Feedwater piping and component support/integral attachment modifications.
6. lEA-1240-13 NIA #13 SIG Feedwater piping and component support/integral attachment modifications.
7. lEA-1240-14 NIA #14 SIG Feedwater piping and component support/integral attachment modifications.
8. lEA-1241-11 NIA #11 SIG Main Steam piping and component support/integral attachment modifications.

Page 13

NIS-1 OWNER'RATA REPORT FOR INSERVICE lsPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1.

Public Service Electric & Gas Co .. 80 Park Plaza. Newark. NJ. 07101 2. Plant Salein Generating Station P.O. Box E. Hancock's Bridge. NJ 08038 3. Plant Unit Unit 1 (Facility Operating License DPR-70) 4. Owner's Certificate of Authorization (if Required)

NI A 5. Commercial Service Date 07/01/77 6. National Board Number for Unit 20757 7. Components inspected (see page 1) 8. Exam Dates March 7. 1995 to March 17. 1998 9. Inspection Interval from February 27. 1988 to July 7. 2001 10. Applicable Edition of ASME Section XI, 1983, through 1983 Summer Addenda 11. Abstract of Examinations:

ITEM PSE&G PSE&G REPAIR/REPLACEMENT/

NO. DCPNO. P.O. NO .. MODIFICATION DESCRIPTION

9. lEA-1241-12 NIA #12 SIG Main Steam piping and component support/integral attachment modifications.
10. lEA-1241-13 NIA #13 SIG Main Steam piping and component support/integral attachment modifications.
11. lEA-1241-14 NIA #14 SIG Main Steam piping and component support/integral attachment modifications.
12. EWP# SLM-01 NIA #11 -14 new Steam Generator Lower Vertical support modifications SwRI found a rejectable PSI indication on the #14 Steam Generator (S/N 2172) Transition Cone to Shell C weld. The rejectable indication was located at the inside surface, approximately 301 inches clock wise from ISI vessel zero. The rejectable indication was reduced in size by mechanical blending to within acceptable limits. There were no other unacceptable indications identified.

Page 14

. -.FORM NIS-1 OWNER'IATA REPORT FOR INSERVICE .PECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1.

Public Service Electric & Gas Co., 80 Park Plaza. Newark. NJ. 07101 2. Plant Salem Generating Station P.O. Box E. Hancock's Bridge. NJ 08038 3. Plant Unit Unit 1 (Facility Operating License DPR-70) 4. Owner's Certificate of Authorization (if Required)

NI A 5. Commercial Service Date 07/01/77 6. National Board Number for Unit 20757 7. Components inspected (see page 1) 8. Exam Dates March 7, 1995 to March 17. 1998 9. Inspection Interval from February 27. 1988 to July 7. 2001 10. Applicable Edition of ASME Section XI, 1983, through 1983 Summer Addenda 11. Abstract of Examinations:

11.19 Erosion/Corrosion UT Thickness Program In response to NRC Bulletin 87-01 and Engineering Directive MEC-94-1071, 130 components were scheduled for UT thickness examinations The following Components were replaced, due to the results of the erosion/corrosion UT examinations performed.

ITEM COMPONENT COMPONENT NO. SYSTEM ID DESCRIPTION

1. Heater Drain A3 18" Orifice 2. Heater Drain A29 18" X 16" X 12" Tee 3. MSR (Reheat Drains) Cl7 3" Tee 4. MSR (Reheat Drains) C18 3" Tee 5. MSR (Reheat Drains) C20 3" Tee 6. MSR (Reheat Drains) C30 3" Tee 7. Misc. Drains H9 3" Orifice 8. Condensate Ml 20" Orifice 9. Condensate M12 24" Elbow As a result of these repairs/replacements, and procedural requirements for readings less than 70 % of nominal wall, an examination expansion of 35 components was performed.

This increased the total number of examinations to 165 components.

The following is a break down of these examinations.

a. Nine components were replaced.
b. 156 were acceptable for continued service, based on minimum wall design requirements
c. No components required a weld build-up.

There were no other unacceptable indications identified.

Page 15

.FORM NIS-1 OWNER'IATA REPORT FOR INSERVICE lsPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1.

Public Service Electric & Gas Co., 80 Park Plaza, Newark. NJ, 07101 2. Plant Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 3. Plant Unit Unit 1 (Facility Operating License DPR-70) 4. Owner's Certificate of Authorization (if Required)

NI A 5. Commercial Service Date 07101/77 6. National Board Number for Unit 20757 7. Components inspected (see page 1) 8. Exam Dates March 7, 1995 to March 17, 1998 9. Inspection Interval from February 27, 1988 to July 7. 2001 10. Applicable Edition of ASME Section XI, 1983, through 1983 Summer Addenda 11. Abstract of Examinations:

11.20 Technical Specification 4.7.9 (c) Functional Testing of Selected Hydraulic and Mechanical Snubbers HYDRAULIC SNUBBERS (FIRST TEST SAMPLE) Hydraulic snubbers were tested using the Technical Specification 4.7.9(c), 10% sample plan by Wyle Laboratories using the API in-place snubber test machine and the Wyle Laboratories model 150 snubber test machine as follows: => Two SIG 1,000 Kip Rexnords => One MSN 200 Kip Paul Monroe => One Lisega small hydraulic snubber All hydraulic snubbers tested satisfactorily, except for the one Lisega small snubber. MECHANICAL SNUBBERS (FIRST TEST SAMPLE) Mechanical snubbers were tested using the Technical Specification 4.7.9(c), 10% sample plan using the Wyle Laboratories model 150 snubber test machine as follows: => Two Mechanical large (PSA-35) => 11 mechanical medium (PSA-1, 3 and 10) => Four mechanical small (PSA-114 and 112) All mechanical snubbers tested satisfactorily, except for the two mechanical medium (PSA-1, 3 and 10) snubbers.

HYDRAULIC AND MECHANICAL EXPANDED SNUBBER TEST SAMPLES Due to Hydraulic and Mechanical snubbers test failures the following expanded snubber test samples were tested using the Wyle Laboratories model 150 snubber test machine. => Four snubbers (100% of the Lisega hydraulic snubbers)

=> Two expanded samples totaling 22 mechanical medium (PSA-1, 3 and 10) PSE&G Engineering performed a stress evaluation on all failed snubber locations and concluded that the piping and components to which the snubbers were attached were not impaired due to in-operability of the snubbers.

Page 16

.. FORM NIS-1 OWNER'"ATA REPORT FOR INSERVICE lsPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES 1.

Public Service Electric & Gas Co., 80 Park Plaza, Newark, NJ, 07101 2. Plant Salem Generating Station P.O. Box E, Hancock's Bridge, NJ 08038 3. Plant Unit Unit 1 (Facility Operating License DPR-70) 4. Owner's Certificate of Authorization (if Required)

NI A 5. Commercial Service Date 07101/77 6. National Board Number for Unit 20757 7. Components inspected (see page 1) 8. Exam Dates March 7, 1995 to March 17, 1998 9. Inspection Interval from February 27, 1988 to July 7, 2001 10. Applicable Edition of ASME Section XI, 1983, through 1983 Summer Addenda 11. Abstract of Examinations:

STEAM GENERATOR REPLACEMENT, MSIV REFURBISHMENT

& MISC. Six SIG snubbers were removed during the SIG replacement and were returned to their position, two SIG snubbers were retested satisfactorily, eight MSIV snubbers were removed for MSIV rebuild and were restored and one retested satisfactorily.

Five none Code pre-NF snubbers were found in the Turbine area and tested and were replaced with new snubbers.

HYDRAULIC AND MECHANICAL SNUBBER EXTENDED OUTAGE SAMPLE Due to the extended outage greater than 18 months, the following hydraulic and mechanical snubbers were tested to comply with Technical Specification 4.7.9 (c) (10% sample): => One 1, 000 Kip Paul Monroe => One 1,000 Kip Rexnord => One 200 Kip Paul Monroe snubbers => One mechanical large (PSA-35) => 11 mechanical medium (PSA-1, 3 and 10) => 100% mechanical small (PSA-114 and 1/2) under a new random sample were previously tested satisfactorily.

Thus, no additional testing was required.

Page 17

  • 11. Abstract of Examinations (see pages 2 -17) 12. ** Abstract of Conditions Notes (see pages 2-17) 13. Abstract of Corrective Measures Recommended and Taken (see pages 2-17) We certify that the statements made in this report are correct and the examinations and corrective measures taken conform to the rules of the ASME Code,Section XI. Certificate of Authorization No. (if applicable) 19 9J' Signed PSE&G, Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by Protection Mutual Insurance Company, DBA Factory Mutual Engineering Association, have inspected the components described in this Owner's Report during the period March 7, 1995 to March 17. 1998, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

/</l:T/CJ 20 National Board, State, Province and Endorsements 19 9'8 Page 18