ML18096B108

From kanterella
Jump to navigation Jump to search
Form NIS-1 Owner Data Rept for Inservice Insps, as Required by Provisions of ASME Code Rules
ML18096B108
Person / Time
Site: Salem PSEG icon.png
Issue date: 11/16/1992
From:
Public Service Enterprise Group
To:
Shared Package
ML18096B107 List:
References
NUDOCS 9211240267
Download: ML18096B108 (242)


Text

{{#Wiki_filter:FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. Owner: Public Service Electric & Gas Co., 80 Park Plaza Newark, N.J. 07101
2. Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. owner's Certificate of Authorization (if required) N/A.
5. Commercial Service Date 7/1/77.
6. National Board Number for Unit: N/A.
7. Examination Dates: 2-26-91 through 4-17-92.
8. This report covers the examinations that were conducted during the 10th Refueling Outage.
9. Components Inspected.

MANUFACTURER STATION OR COMPONENTS OR MANUFACTURER OR INSTALLER PROVINCE NATIONAL APPURTENANCE OR INSTALLER SER. NO. NUMBER BOARD NO.

        #1 Reactor         Combustion      66201 Head Vessel             Engineering     66101 Vessel     N/A     20757
        #11 Steam          Westinghouse      1003           N/A     68-10 Generator          Tampa Div.

P.O. Box - 19218 Tampa, FL 33616

        #12 steam Generator          II  II 1022            N/A    68-08
        #13 Steam Generator          "   II 1023            N/A    68-09
        #14 Steam Generator          II  II 1203            N/A    68-51
        #11 Regen.         Sentry Equip. 4195-A4         N/A    385, 386, Ht. Exch.          Corp.              7' 8' 9               387 Oconomowoc, WI 92l 1240267 921116 PDR   ADOCK 05000272               Page 1 of 21 G                   PDR

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASKE CODE RULES

1. Owner: Public Service Electric & Gas co., 80 Park Plaza Newark, N.J. 07101
2. Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. Owner's Certificate of Authorization (if required) N/A.
5. Commercial Service Date 7/1/77.
6. National Board Number for Unit N/A.
7. Examination Dates: 2-26-91 through 4-17-92.
9. Components Inspected (cont'd):

MANUFACTURER STATION OR COMPONENTS OR MANUFACTURER OR INSTALLER PROVINCE NATIONAL APPURTENANCE OR INSTALLER SER. NO. NUMBER BOARD NO.

 #1 Pressur-      Delta Southern      1011         N/A      68-8 izer Chemical         United Engineers Volume &         & Constructors Control          (UE&C) 30 South      N/A         N/A       N/A Piping           17th st., Phila.

System PA 19101 Containment UE&C N/A N/A N/A Spray Piping System Mains team UE&C N/A N/A N/A Piping sys.

 #1 Volume         Joseph Oat         1781-2A      N/A       374 control        & Sons, Inc.

Tank Camden, N.J.

 #1 Excess         Atlas Industries     850        N/A       701 Letdown Heat      81 Somerset Place Exchanger         Clifton, N.J.
 #1 Letdown        Atlas Industries     N/A        N/A       694 Heat Exc:tianger
 #1 RHR Heat       Engineers &-       S15860-C     N/A       122 Exchanger         Fabricators, Inc.
  • Page 2 of 21

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASKE CODE RULES

1. Owner: Public Service Electric & Gas Co., 80 Park Plaza Newark, N.J. 07101
  • 2.

3. 4. 5. 6. Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038 Plant Unit 1 Owner's Certificate of Authorization (if required) N/A. commercial Service Date 7/1/77. National Board Number for Unit N/A.

7. Examination Dates: 2-26-91 through 4-17-92.
9. Components Inspected (cont'd).:

MANUFACTURER STATION OR COMPONENTS OR MANUFACTURER OR INSTALLER PROVINCE NATIONAL APPURTENANCE OR INSTALLER SER. NO. NUMBER BOARD NO. Pressurizer UE&C N/A N/A N/A Relief Piping Sys. Reactor UE&C N/A N/A N/A Coolant Piping Sys Steam Gen. UE&C N/A N/A N/A Feed Piping System Safety UE&C N/A N/A N/A Injection Piping Sys *

  • Page 3 of 21

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASKE CODE RULES "' 1. Owner: Public Service Electric & Gas Co., so Park Plaza Newark, N.J. 07101

2. Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. Owner's Certificate of Authorization (if required) N/A.
5. commercial Service Date 7/1/77.
6. National Board Number for Unit N/A.
7. Examination Dates: 2-26-91 through 4-17-92.
10. Abstracts of Examinations:

10.1 Examinations were conducted by PSE&G as well as compa-nies under contract to PSE&G. The following examina-tion summary (Section 11) is a brief summary with further details found in the attached report and on file at the Salem Generating Station. Since nearly all inservice examination requirements can be found in Salem's Technical Specifications, this summary lists these requirements first arranged by Tech. Spec. paragraph number followed by applicable NRC circulars and bulletins.

11. Examination Summary:

11.1 Technical Specificat1on 4.0.5 - ASME Section XI The examinations were conducted during the tenth re-

  • fueling ISI outage at Salem Unit 1. These examinations constituted the third ISI performed at Salem Unit 1 during the second - ten year interval of operation.

The components were examined in accordance with "Exami-nation Plan for the 1992 Inservice Examination of Salem generating Station, Unit 1" *

  • Page 4 of 21

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. owner: Public Service Electric & Gas Co., 80 Park Plaza Newark, N.J. 07101
2. Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. owner's Certificate of Authorization (if required) N/A.
5. Commercial Service Date 7/1/77.
6. National Board Number for Unit N/A.
7. Examination Dates: 2-26-91 through 4-17-92.
11. Examination summary (cont'd):

11

  • 1 (cont * )

11.1.1 ISI Examination Southwes.t Research Institute ( SWRI) under the direction of the Salem ISI Group conducted eighty-two (82) ultrasonic, one hundred thirty-one (131) liquid penetrant, fifty-six (56) magnetic particle, and one (1) visual examina-tion. The examinations were conducted on the following welds and components: Class 1 Components Vessels

  • Piping Reactor Pressure Vessel Closure head Pressurizer Chemical and Volume Control System Pressure Relief System Pressurizing System Reactor Coolant System Residual Heat Removal System Safety Injection System Pumps Reactor Coolant Pump Bolts and Flywheels Class 2 Components Vessels Steam Generator Boron Injection Tank Piping Feedwater System Main Steam System i I

Page 5 of 21

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASHE CODE RULES

1. owner: Public Service Electric & Gas Co., so Park Plaza Newark, N.J. 07101
2. Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. owner's Certificate of Authorization (if required) N/A.
5. Commercial Service Date 7/1/77.
6. National Board Number for Unit N/A.
7. Examination Dates: 2-26-91 through 4-17-92~
11. Examination Summary (cont'd):

11.1.2 UT examination of #12 Steam Generator transi-tion cone to shell weld per PSE&G's response to I.E. Notice 90-04. 11.1.3 The following recordable indications were reported during the course of the examinations. A. During the PT examinations, recordable indications were revealed in nine examina-tion areas. These indications were report-ed to PSE&G on customer notification Forms (CNFs) SAM 1-1 through 1-6, 1-6A, 1-6B, 1-6C and 1-7 through 1-9. One indication was resolved as "Code allowable" and accepted "as is". Seven indications were removed with cosmetic buffing. One was mechanical-ly removed after confirmation and accept-ance with the UT method

  • B. During the MT examinations, recordable indications were revealed in three areas.

One was resolved as "code allowable" and accepted "as is". One indication was mechanically removed after sizing with the UT method *. The other was recorded as being outside the American Society of Mechanical

  • Engineers Section XI examination area on the adjacent valve casting. These indica-tions were reported to PSE&G on CNFs SAM 1-10, 1-11, 1-llA, 1-llB and 1-12.

11.1.4 There were no other reportable indications identified during this ISI *

  • Page 6 of 21

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASHE CODE RULES "' 1. owner: Public Service Electric & Gas co., 80 Park Plaza Newark, N.J. 07101

2. Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. owner's Certificate of Authorization (if required) N/A.
5. Commercial Service Date 7/1/77.
6. National Board Number for Unit N/A.
7. Examination Dates: 2-26-91 through 4-17-92.
11. Examination Summary (cont'd):

11.1.5 Visual Examinations A. Contract personnel under the direction of the Salem ISI Group conducted visual exami-nations on seventy-six Nuclear Class I, eighty-two Nuclear Class II eighty-eight Nuclear Class III supports. There were several minor discrepancies noted includ-ing; wrong spring settings, rust, loose bolts, etc *. Work orders and/or deficiency reports were generated to document and correct all discrepancies. As a result of some of the discrepancies, twenty-one additional support exams were scheduled and performed satisfactory. B. PSE&G conducted VT-1 visual examinations of

  • Nuclear Class 1 bolting on five components (valves and/or flanges) satisfying ASME Section XI B-G-2 examination requirements.

Results of these examinations were satis-factory.

c. PSE&G conducted VT-3 visual examinations of five components (vessel and/or pump) sup-ports to satisfy examination category D-A, D-B, and F-A of ASME Section XI. Results of these examinations were satisfactory .
  • Page 7 of 21

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASKE CODE RULES ' ' 1. Owner: Public Service Electric & Gas Co., 80 Park Plaza Newark, N.J. 07101

2. Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. owner's Certificate of Authorization (if required) N/A.
5. Commercial Service Date 7/1/77.
6. National Board Number for Unit N/A.
7. Examination Dates: 2-26-91 through 4-17-92.
11. Examination Summary (cont'd):

11.1.6 System Pressure Tests Summary System leakage exams were performed in accord-ance with ASME Section XI on all Nuclear Class 1 systems. System functional Tests/system inservice tests were performed on those Nuclear Class 2 and 3 systems required to satisfy a percentage of the requirements for the second inspection period. Results None of the systems tested exhibited any exces-sive leakage. There was some minor mechanical leakage which was identified and work orders were written to correct. 11.2 Technical Specification 4.7.9 (a) Visual Inspection of Hydraulic and Mechanical Snubbers 11.2.1 Summary Contract.and PSE&G personnel under the direc-tion of.the Salem ISI Group conducted visual examinations on one hundred and sixteen mechan-ical snubbers and twenty-four hydraulic snub-bers. 11.2.2 Results There were no discrepancies noted which would affect snubber operability. There were some minor items noted including reservoirs not full, missing washers, loose spherical bearings and binding around the bearings, and some light corrosion. These conditions were all noted and corrected. All snubbers which were removed and reinstalled for functional testing received an "As-Left"

  • visual exa~ination.

Page 8 of 21

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. owner: Public Service Electric & Gas Co., 80 Park Plaza Newark, N.J. 07101
2. Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. owner's Certificate of Authorization (if required) N/A.
5. commercial Service Date 7/1/77.
6. National Board Number for Unit N/A.
7. Examination Dates:. 2-26-91 through 4-17-92.
11. Examination Summary (cont'd):

11.3 Technical Specification 4.7.9 (c) "Functional Testing of Selected Hydraulic and Mechanical snubbers" 11.3.1 Summary - Hydraulic Snubbers Per Technical Specifications, 10% of the in-stalled hydraulic snubbers as well as all previous outage functional test failures are required to be tested. The 10% sample included one 200 KIP Main Steam snubber and two 1000 KIP Steam Generator snubbers. There were no previ-ous outage test failures.

           *11.3.2 Results - Hydraulic Snubbers There were noted discrepancies in the Tech.

Spec. sample .

  • 11.3.3 Summary - Mechanical Snubbers Per Technical Specifications, 10% of the total installed mechanical snubbers as well as previ-ous outage functional test failures were tested utilizing the WYLE Model 150 Snubber Testing machine. The 10% sample is broken down by snubber category size (small and medium) with 10% from each size selected each outage. All selected snubbers are detailed below:

A. The 10% sample of the medium size snubbers included four (4) PSA-l's, six (6) PSA-3's, one (1) PSA-10 and one (1) PSA-35. B. Due to previous outage failures, 100% of the small size snubbers (PSA-1/4's, PSA-1/2") and equiv. hydraulic snubbers are tested each outage. This resulted in tests being performed on one Model 1/4, three Model 1/2 and one.Lisega HSML *

  • Page 9 of 21

FORK NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. Owner: Public Service Electric & Gas Co., 80 Park Plaza Newark, N.J. 07101 2
  • Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. owner's Certificate of Authorization (if required) N/A.
5. Commercial Service Date 7/1/77.
6. National Board Nwnber for Unit N/A.
7. Examination Dates: 2-26-91 through 4-17-92.
11. Examination Summary (cont'd):

11.3.4 Results - Mechanical Snubbers A. All the medium size Tech. Spec. sample snubbers were tested satisfactory. B. All the small size snubber and equivalent hydraulic snubbers were tested satisfacto-ry. 11.4 NRC Circular 76-06 and NRC Bulletin 79-17 "Commitment to Examine and/or Flush Stainless Steel Lines Contain-ing Borated Water.

  • 11.4.1 Southwest Research Institute (SwRI) under the direction of the Salem ISI Group performed ultrasonic examinations on fourteen welds. No recordable indications were noted .
  • 11.4.2 Quarterly chemistry samples were taken by the PSE&G Chemistry Department and the results were transmitted to the Salem ISI Group per the Chemistry procedure. During the past 18 months, this program identified a few noncon-formances. The nonconforming pipe was flushed and a new sample taken to verify it met the acceptance criteria.

11.5 Technical Specification 4.4.11.1 Reactor Coolant Pump

            .Flywheel Examination (USNRC Regulatory Guide 1.14,
           * "Reactor Coolant Pump Flywheel Integrity").

11.5.1 Summary Southwest Research Institute (SwRI) performed examinations on Reactor Coolant Pump (RCP) Flywheels. Flywheels are tracked by RCP Motor serial number and original pump location, however, many have been moved to different pump locations throughout outages. The exam results are as follows: A. Performed "UT" examination of the top side of serial # 35-76P-917 which was originally

  • installed in #23 pump and is now installed in #12 pump. Exam performed in-place.

Page 10 of 21

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASHE CODE RULES 1. Owner: Public Service Electric & Gas Co., 80 Park Plaza Newark, N.J. 07101

  • 2. Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. Owner's Certificate of Authorization (if required) N/A.
5. Commercial Service Date 7/1/77.
6. National Board Number for Unit N/A.
7. Examination Dates: 2-26-91 through 4-17-92.
11. Examination Summary (cont'd):

B. Performed "UT" examination of the top side of serial # 45-75P-790 which was originally installed in #14 pump and is now installed in #11 pump. Exam performed in-place. 11.5.2 Results No discrepancies were noted. 11.6 NRC Bulletin 87-01 "Thinning of Pipe Walls in Nuclear Power Plants".

11. 6 .1 Summary Southwest Research Institute (SwRI) and General Electric Co. under the direction of the Salem ISI Group performed ultrasonic thickness meas-urements on eighty-one piping components as identified by PSE&G engineering.

11.6.2 Results Any areas identified having a wall thickness below minimum wall were submitted to PSE&G Engineering Department for disposition. 11.7 NRC Bulletin 82-02 "Degradation of Threaded Fasteners

             .*in the Reactor Coolant Pressure Boundary of Power Plants".

11.7.1 Summary Visual (VT) and Magnetic Particle (MT) exams were performed on the primary manway bolts for all four Steam Generators. In addition, a VT exam was performed on all four Reactor Coolant Pumps main flange bolting .

  • Page 11 of 21

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES ' ' 1. Owner: Public Service Electric & Gas co., 80 Park Plaza Newark, N.J. 07101

  • 2. Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. owner's Certificate of Authorization (if required) N/A.
5. commercial service Date 7/1/77.
6. National Board Number for Unit N/A.
7. Examination Dates: 2-26-91 through 4-17-92.
11. Examination summary (cont'd):

11.7.2 Results One bolt on #14 Steam Generator.hot leg had minor indications observed during the visual examinations. Deficiency Reports and Code Job Packages were prepared to replace these bolts in kind. There were no discrepancies noted on the Reactor Coolant Pump flange bolting. 11.8 NRC Bulletin 88-08 "Thermal Stresses in Piping Connect-ed to reactor coolant System" *

               . 11.8.1    Southwest Research Institute (SwRI),

under the direction of the Salem ISI Group, performed augmented ultrasonic and dye pene-trant examinations on seventeen 1.5" Safety Injection welds, two 2 11 and two 3" Chemical and

  • 11.9 Volume Control system welds for the third consecutive outage. No discrepancies were noted.

NRC Bulletin 88-11 "Pressurizer Surge Line Thermal Stratification". 11.9.1 summary The Salem ISI Group performed visual examina-tions on all the existing surge line pipe supports\HEBA restraints and any insulation damage. A total of nine supports were exam-ined.

11. 9 . 2 Results No discrepancies were noted. Results were forwarded ~o system engineering *
  • Page 12 of 21

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE ROLES

1. Owner: Public Service Electric & Gas Co., 80 Park Plaza Newark, N.J. 07101
2. Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. Owner's Certificate of Authorization (if required) N/A.
5. commercial Service*Date 7/1/77.
6. National Board Number for Unit N/A.
7. Examination Dates: 2-26-91 through 4-17-92.
11. Examination Summary (cont'd):

11.10 Technical Specification 4.4.5.0 - Steam Generator Tube eddy current inspection. 11.10.l The original eddy current examination scope is detailed below: A. Three percent Tech. Spec bobbin coil exami-nation in #11, #12, #13 and #14 steam generators (102 tubes per steam generator). B. A non-tech spec sample of six hundred ten tubes in #11 steam generator per Engineer-ing's recommendation to comply with EPRI recommended guidelines of performing 100% examination of all steam generator tubes over a six year period. This sample com-bined with the tech Spec sample brings the

  • c.

total percentage of tubes inspected in this generator for this outage to 21%. A non-tech. spec. sample of six hundred forty-one tubes in #12 steam generator per Engineering's ~ecommendation to comply with EPRI recommended guidelines of performing 100% examination of all steam generator tub~s over a* six year period. This sample combined with.the tech. Spec. sample brings the total percentage of tubes inspected in this generator for this outage to 22%. D. A non-tech. spec sample of six hundred and nine tubes in #13 'steam generator per Engineering's recommendation to comply with EPRI recommended guidelines of performing 100% examination of all steam generator tubes over a six year period. This sample combined with the Tech. Spec. sample brings the total percentage of tubes inspected in this generator for this outage to 21% .

  • Page 13 of 21

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY TBE PROVISIONS OF THE ASME CODE RULES

1. owner: Public Service Electric & Gas co.," so Park Plaza Newark, N.J. 07101
  • 2. Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. owner's Certificate of Authorization (if required) N/A.
5. Com.n;lercial Service Date 7/1/77.
6. National Board Number for Unit N/A.
7. Examination Dates: 2-26-91 through 4-17-92.
11. Examination Summary (cont'd):

D. A non-tech. spec sample of six hundred thirty-one tubes in #14 steam generator per Engineering's recommendation to comply with EPRI recommended guidelines of performing 100' examination of all steam generator tubes over a six year period. This sample combined with the Tech. Spec. sample brings the total percentage of tubes inspected in this generator for this outage to 21%. E. A twenty percent inspection (approximately 680 tubes) in #11, #12, #13 and #14 steam generators with rotating pancake probe to address the concern of Expansion Zone Pure Water Stress Corrosion Cracking at the hot leg tube sheet (WETEX) for steam generators manufactured using explosive tube expansion

  • F.

techniques. A seven percent inspection (approximately 240) in #11, #12, #13 and #14 steam genera-tors with rotating pancake probe at multi-ple support plate intersections. 11.10.2 The results of the eddy current inspections are as follows: A. The Tech. Spec. sample in #11, #12, #13 and

                         #14 steam generators revealed no indication equal to or exceeding the plugging limit and satisfied the less than 5% of the inspected tubes being degraded therefore no scope expansion was required.

B. Zero tubes in #11 steam generator were required to be plugged due to eddy current indications.

c. One tube in #12 steam generator was re-quired to be plugged due to an eddy current indication on the non-tech. spec. sample exceeding the plugging limit .
  • Page 14 of 21

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASHE CODE RULES ' 1. Owner: Public Service Electric & Gas Co., 80 Park Plaza Newark, N.J. 07101

  • 2. Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. Owner's Certificate of Authorization (if required) N/A.
5. Commercial service Date 7/1/77.
6. National Board Number for Unit N/A.
7. Examination Oates: 2-26-91 through 4-17-92.
11. Examination summary (cont'd):
o. Two tubes in #13 steam generator were required to be plugged due to eddy current indication~ in the non-tech. spec. sample exceeding the plugging limit. In addition, one tube was preventively plugged due to an eddy current indication in the 35% to 39%

through wall range. E. Zero tubes in #14 steam generator were required to be plugged due to eddy current indications exceeding the plugging limit however two tubes were preventively plugged due to eddy. current indications in the 35% to 39% through wall range *

  • Page 15 of 21.

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. Owner: Public Service Electric & Gas Co., 80 Park Plaza Newark, N.J. 07101 2 . Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. owner's Certificate of Authorization (if required) N/A.
5. Commercial Service Date 7/1/77.
6. National Board Number for Unit N/A.
7. Examination Dates: 2-26-91 through 4-17-92.
11. Examination Summary (cont'd):

steam Extent of No. of Tubes Tubes with Indications Generator Exam. Inspected < 20%. 20-39% > 40% 11 Full Length 712 9 16 0 Bobbin Coil RCP at Support 237 0 0 0 Plates RCP of Tubesheet 680 0 0 0 12 Full Length 743 20 41 1 Bobbin Coil RCP at support 240 0 0 0 Plates

  • 13 RCP of Tubesheet Full Length Bobbin Coil RCP at Support 678 711 241 0

8 0 0 10 0 0 1 0 Plates RCP of Tubesheet 687 0 0 0 14 Full Length 733 15 39 0 Bobbin Coil RCP at support 241 0 0 0 Plates RCP of Tubesheet 678 0 0 0 Sub~Total Full Length 2899 52 106 2 Support Plates 959 0 0 0 Tube sheet 2723 0 0 1 TOTAL 6581 52 106 3

  • Page 16 of 21

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASHE CODE ROLES

1. Owner: Public Service Electric & Gas Co., 80 Park Plaza Newark, N.J. 07101
  • 2. Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. Owner's Certificate of Authorization (if required) N/A.
5. Commercial Service Date 7/1/77.
6. National Board Number for Unit N/A.
7. Examination Dates: 2-26-91 through 4-17-92.
11. Examination summary (cont'd):

11.10.3 Additional Steam Generator Work A. Helium leak detection was performed on #11 steam generator to locate the source of primary to secondary leakage. No positive evidence of primary to secondary leakage was observed using the Helium Leak Detec-tion Technique however tubesheet video scan during helium pressurization revealed an excessive amount of boron deposits observed surrounding the explosive plugs located in Row 1 Column 91 hot leg and Row 1 Column 2 in the cold leg. The explosive plugs in these locations were remotely machined and replaced with short standard type Inconel 690 mechanical plugs .

  • B. All explosive plugs in both legs of #11 steam generator were scheduled for replace-ment. These plugs were located at Row 1 Columns 1-5 and 90-94 in both legs, twenty total. Due to difficulties encountered while attempting to machine the explosive plugs and time constraints, only six of the twenty plugs were removed. Four of these plugs were reported as having both boron deposits surrounding them during helium pressurization and were successfully re-moved (see above). In addition the explo-sive plugs in Row 1 Column 5 hot and cold were removed and replaced with a short standard type Inconel mechanical plug *
  • Page 17 of 21

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASME CODE RULES

1. Owner: Public Service Electric & Gas Co., 80 Park Plaza Newark, N.J. 07101
  • 2. Plant: Salem Generating Station P.O. Box 236, Hancock'~ Bridge, N.J.
3. Plant Unit 1 08038
4. Owner's Certificate of Authorization (if required) N/A.
5. Commercial Service Date 7/1/77.
6. National Board Number for Unit N/A.
7. Examination Dates: 2-26-91 through 4-17-92.
11. Examination Summary (cont'd):

11.10.4 Current status of Steam Generators At this time, the total number of tubes plugged in the Salem Unit 1 steam Generators are as follows:,

  • S/G 11 S/G 12 S/G 13 S/G 14 Plugs repaired this outage 6 0 0 0 New tubes plunged this outage 0 1 3 2 Tubes previously plugged 104 120 109 141 Total tubes plugged 104 121 112 143
  • 11.11 Technical Specification 4.6.1.2 (d) Containment Type "B" (Penetrations) and "C" (Valves) Leak Rate Testing.
11. 11. 1 Summary The PSE&G Research Corp. under the field super-vision of the Salem ISI Group, conducted leak rate tests on sixty-three Type "B" Electrical Penetrations, seven Type "B" Mechanical Pene-trations and fifty-five Type "C" Mechanical penetrations (113 valves).

11.11. 2 Results A. Several Type "C" valves exceeded the recom-mended leak rate acceptance criteria. These valves were reworked to an acceptable condition and retested satisfactorily. B. A total As-Found leakage of 32,432.7 SCCM was measured through all Type 11 Bil and 88 C" containment penetrations. After corrective maintenance, a total As-Left leakage of 22,338.2 was measured through all Type "B" and "C" penetrations

  • Page 18 of 21

FORM HIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASHE CODE RULES

1. Owner: Public Service Electric & Gas Co., 80 Park Plaza Newark, N.J. 07101
  • 2. Plant: Salem Generating Station P.O. Box 236, 4.

5. Hancock's Bridge, N.J. 08038

3. Plant Unit 1 Owner's Certificate of Authorization (if required) N/A.

Commercial Service Date 7/1/77.

6. National Board Number for Unit N/A.
7. Examination Dates: 2-26-91 through 4-17-92.
11. Examination Summary (cont'd):

11.12 Technical Specification 4.6.l.3b Elevation 100 1 and 130' Airlock Leak Rate Tests 11.12.1 Summary PSE&G Research Corp. under the field supervi-sion of the Salem ISI Group, conducted leak rate tests on the 100' and 130' containment personnel airlocks. 11.12.2 Results The combined As-Found leakage for these air-locks was 8,340.0 SCCM. After scheduled pre-ventative maintenance, the combined As-Left leakage for the airlocks was 9,500.0 SCCM. Both of these measured combined leakage rates satisfy the Technical Specification acceptance criteria of s 0.05 La (10,812 SCCM). 11.13 NUREG 0578 - "TMI Lessons Learned - Performing Service Leak Exams, measuring leakage outside Containment, and take corrective actions necessary to reduce leakage as low as possible on systems likely to contain radioac-tive liquids in the event of an accident. 11.13.1 Summary A. Th.e saiem ISI Group performed service pressure leak exams on the Safety injec-tion, Chemical and Volume Control, Residual Heat Removal and Containment Spray Systems. B. The PSE&G Research Corp., under the direc-tion of the Salem ISI Group conducted the Waste Gas System Leak Test in accordance with Site Service procedure sc.ss-IS.WG-0003 (R) .

  • Page 19 of 21

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY THE PROVISIONS OF THE ASHE CODE RULES

1. Owner: Public Service Electric & Gas Co., 80 Park Plaza Newark, N.J. 07101
2. Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. owner's Certificate of Authorization (if required) N/A.
5. commercial service Date 7/1/77.
6. National Board Number for Unit N/A.
7. Examination Dates: 2-26-91 through 4-17-92.
11. Examination . Summary (cont'd) :

11.13.2 Results A. The waste Gas Decay Tanks, waste Gas Suc-tion and Discharge Headers and #11 Waste Gas Compressor showed no adverse findings relative to this bulletin. B. #12 Waste Gas Compressor could not .be tested. because it is out of service await-ing breaker maintenance. The activity to perform a leak rate check remains open until the breaker is repaired.

c. The leak rate test on the 1WG41 valve was acceptable with a measured leakage of 1,629 SCCM which is below the acceptance criteria of 1,850 SCCM .

11.14 Field Directive, S-C-R700-MFD-288, "Leak Rate test Program for the Steam Generator Blowdown Isolation Valve (GB4) 11.14.1 PSE&G*Research and Testing Lab under the field supervision of the Salem ISI Group, conducted leak rate tests on all four Steam Generator Blowdown Valves (GB-4's) in accordance with Site Service procedure SC.SS-IS.GB-0004(Q).

              11.14.2 Results All f.our valves had an acceptable leak rates below the test acceptance criteria of s 30,000 SCCM. No discrepancies were noted
  • Page 20 of 21

FORM HIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS AS REQUIRED BY TBB PROVISIONS OF THE ASHE CODE RULES

1. Owner: Public Service Electric & Gas Co., 80 Park Plaza Newark, N.J. 07101
2. Plant: Salem Generating Station P.O. Box 236, Hancock's Bridge, N.J. 08038
3. Plant Unit 1
4. Owner's Certificate of Authorization (if required) N/A.
5. Commercial Service Date 7/1/77.
6. National Board Number for Unit N/A.
7. Examination Dates: 2-26-91 through 4-17-92.
11. Examination Summary (cont'd):

we certify that the statements made in this report are correct and the examinations and corrective measures taken conform to the rules of the ASME Code, Section X

  • Date J./gl/ 3 ' 19 ~ Signed PSE&G Owner Certificate of Authorization Expiration Date N/A CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and/or the State or Province of New Jersey and employed by Arkwright Mutual Insurance company, Norwood, Massachusetts, have inspected the components described in this Ownerws Data Report during the period 02-26-91 to 04-17~92 and state that to the best of my knowledge and belief the Owner has performed examinations and taken corrective measures described in this Owner's *Data Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employ-er makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this owner's Data Report. Furthermore, neither the Inspector nor his employer

  • shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspectio~.

Date __.......2ltw~---"""'-' 19 uFactory Mutual systems

                                                               ~  'I Conmlissions   /JTJ19    I National Board, State, Province and No *
  • Page 21 of 21
  • A IL DISCUSSION OF EXAMINATION ACTIVITIES Pre-Outage Planning In order to assure efficient performance of the ISI, SwRI devoted a concentrated effort toward planning and preparation for the examination activities. This included review of the Long-Term Plan, scrutinizing calibration block configuration to ensure that they met the requirements for the 83/S83 Code, and developing nuclear projects operating procedures_ (NPOPs) to supplement the PSE&G preapproved listing of NPOPs. These activities were accomplished by SwRI's NDE Engineering Section with assistance provided by the NDE Applications Section culminating in the development of an Examination Plan.

The Examination Plan was developed to provide the basis for the ISi in one comprehensive document. It provided a listing of the examination areas, copies of all procedures, calibration block drawings, weld identification figures, and other information pertinent to the performance of the ISI. The Examination Plan was reviewed and approved by PSE&G prior to SwRI's arrival on site. B. Examination Procedures and Personnel The NDE activities were performed using visual (VT), liquid penetrant (PT), magnetic particle (MT), and manual ultrasonic (UT) techniques. These examinations were performed by Sw RI and Sonic Systems International, Inc. (SSI), personnel in accordance with SwRI NPOPs which had been preapproved by PSE&G personnel SwRI NPOPs were utilized to provide guidelines and controls for performance of onsite

  • examination activities. This included procedures for weld joint identification marking, indication recording, records control, and resolution of indications.

NPOPs were written to conform to the requirements of the applicable sections of the ASME B&PV Code and SwRI's NQAPM. Some procedures were amended for specific examination purposes with Interim Change Notices (ICNs). These ICNs were necessary to incorporate exami-nation requirements unique to particular examinations at Salem 1. The ICNs used are noted on the individual examination data sheets, NDE Summary Tables, and copies of the ICNs and their respective NPOPs are located in Appendix C. SwRI examination personnel were Certified in accordance with SwRI NPOP 2.0-NDES-101, "Nondestructive Examination Personnel Qualification and Certification," which incorporates the guidelines of SNT-TC-lA of the American Society for Nondestructive Test~g and ASME Section XI B&PV Code. The SSI examiner was certified in accordance with SSI's training, qualification, and certification procedure number SSI-A-005, which complies with SNT-TC-lA. A copy of each examin~r's certifications is included in Appendix E. C. El'3mjnation Activities This subsection provides a discussion of the various NDE activities performed during the ISI. SwRI examination data records are included in Volumes ill through V. A discussion of equip-ment and materials used for these examinations appears in Subsections E and F of this section of the report.

  • washers.*

VT examinations were perfo.rmed on the reactor pressure vessel (RPV) closure head i 3 __J

Solvent removable visible dye penetrant examinations were performed by SwRI personnel on selected Class 1 and Class 2 piping and support welds.

3. MT .Emmination.r Examination personnel used an AC yoke and dry particle MT to examine supports on the boron injection tank, and piping welds within the Feedwater and Main Steam Systems.

Fluorescent MT was performed on the RPV studs and nuts. UT examinations were performed on Class 1 and Class 2 components, including vessels, studs, austenitic piping. ferritic piping,; and dissimilar metal welds. Various techniques were used to perform the UT examinations, depending on material type and weld thickness. For typical vessel and piping examinations, the following techniques were used:

a. A 0-degree lamination scan (UTOL) was used for detection of laminar reflectors which might affect interpretation of angle-beam results.
b. A 0-degree scan (UTOW) was used for detection of reflectors in the weld for vessel examinations.
c. For austenitic and ferritic welds, angle-beam scans of 45 degrees (UT45) were used for detection of reflectors oriented parallel to the weld .
  • d e.

Angle-beam scans, using 45-degree *search units directed parallel to the weld (UT4ST) were used on piping for detection of reflectors oriented transverse to the weld. For vessel examinations, 45- and 60-degree scans parallel to the weld were performed for detection of transverse reflectors. For selected dissimilar metal welds, augmented 45.cfegree refracted longitudinal examinations were also used for detection of reflectors oriented parallel and transverse to the .weld Thickness measurements were recorded using SwRI's Thickness Data Acquisition System (IDAS) at 58 pipe locations to identify possible corrosion/erosion. Results of the IDAS examinations in the form of thickness plots for each fitting were reported to PSE&G personnel during the examinations, and a separate summary report was submitted. At the request of PSE&G, two special series of examinations were performed:

a. In response to Nuclear Regulatory Commission (NRC) Bulletin 76-06, "Stress Corrosion Cracks in Stagnant, Low Pressure Piping Containing Boric Acid Solution at PWR's," one 14-inch Residual Heat Remov~ two 10-inch Safety Injection, one 8-inch Safety Injection, seven 6-inch Safety Injection, and three 4-inch Safety Injection welds were examined.
  • 4
b. In response to NRC Bulletin No. 88-08, "Thermal Stresses in Piping Connected to Reactor Coolant Systems," seventeen 1.5-inch Safety Injection and two 2-inch and two 3-inch Chemical and Volume Control welds were examined with UT for the third consecutive outage.

D. Examination Results PT examinations revealed the following indications: Description Resolutfon CNf No. 2-SJ-1137-12 7/32-inch linear indication Reexamination after SAM 1-1 Pipe to Valve on base material of pipe cosmetic buffing revealed no recordable indications. 2-SJ-2160-10 Two linear indications, one Reexamination after SAM 1*2 Elbow to Pipe 3/8-inch, one 9/32-inch on cosmetic buffing revealed base material of elbow no recordable indications. 2-SJ-2160-9 1/8-inch linear indication Reexamination after SAM 1-3 Pipe to Elbow on base material of elbow cosmetic buffing revealed no recordable indications. 2-CV-2147-14 3/8-inch linear indication Reexamination after SAM 1-4 Pipe to Elbow on base material of elbow cosmetic buffing revealed no recordable indications.

  • 4-SJ-2150-14 Pipe to Valve 6-PR-1103-12 Elbow to Flange 3/16-inch round indication 1/2 inch from fusion line on pipe side of weld Four linear indications, one 3/4 inch, one 1/8 inch Reexamination after cosmetic buffing revealed no recordable indications.

Reexamination after mechanical removal SAM 1-5 SAM 1-6, 1-6A, 1-6B, and two 3/16 inch on revealed no recordable 1-6C Flange side 1/2 inch from indications. weld centerline. 6-PR-1105-1 . 3/16-inch linear indication Indication is allowable by SAM 1*7 Nozzle to Safe on nozzle side, 1/4 inch Code. Accepted "as is11 by End from weld centerline PSE&G personnel 1-1/2-SJ-1132-40 1/4-inch linear indication Reexamination after SAM 1-8 Valve to Pipe on base material of valve cosmetic buffing revealed no recordable indications. 6-SJ-1141-1 9-inch linear indication on Reexamination after SAM 1-9 Reducer to Elbow weld. cosmetic buffing revealed no recordable indications.

  • 5

MT examinations revealed the following indications: Ara Description Resolution CNF No. 34-MS-2131-lPL- 1/4-inch linear indication Indication is allowable by SAM 1-10 19 Pipe Lug on lug side Code. Accepted "as is" by PSE&G personnel 34-MS-2121-2 1-inch linear indication at Reexamination after SAM 1-11, Pipe to Valve fusion line on valve mechanical removal 1-llA, revealed no recordable 1-llB indications. 34-MS-2141-2 13/16-inch linear PSE&G personnel SAM 1-12 Pipe to Valve indication outside Code- forwarded to their required examination area Engineering for on valve body disposition. Seat 92-322. vr and UT examinations revealed no reportable indications. At the request of PSE&G personne~ each examination area was checked to ensure that the appropriate identification number and L0 was etched or stamped on it. PSE&G-developed forms were used to report variances from the requirement. Copies of the CNFs are included in Appendix G. E. Equipment Various NDE equipment was used during the ISi to perform the examinations of the selected components. The major equipment items are discussed below. Sonic 136 and FrS Mark I UT instruments were used for the NDE activities. To assure proper instrument linearity and operation, SwRI certified each instrument prior to use at Salem Unit 1, as specified in the NQAPM. Copies of certifications for those instruments utilized at Salem Unit 1 are contained in Appendix F. In addition, instrument linearity measurements were taken before and aft.er completion of site activities as specified in SwRI NPOP SwRI-NDES, "Ultrasonic Linearity Measurements." 2 Transducen Various brands, sizes, and frequencies of UT transducers were used to perform the examinations. A transducer frequency of 1.5, 2.25, 5.0, or 10.0 MHz was used as specified in the applicable NPOP. Prior to use at Salem l, each transducer was tested and certified to be within SwRI's acceptance standards. This certification is performed within 12 months of use to verify that each transducer is performing within standards. A copy of each transducer's certification is contained in Appendix F. Information on the actual transducer used for any specific examination may be deter-

  • mined by reviewing the data sheets and referenced calibration sheets in the field data volumes.

6 I

  • F.

Hand-held alternating current magnetic particle yokes were used for MT examinations. Materials In addition to the equipment previously discussed, certain materials were required in the performance of the examinations. All materials contacting the examination surface (i.e., glycerine, pipe marking pencils, penetrants, etc.) were tested and certified to be within acceptable sulfur and halogen

  • limits prior to use at Salem 1. Certifications for these materials are contained in Appendix F.

G. ur Calibration B1oclm Pipe and vessel cah"bration blocks were utilized to cah"brate the UT instruments prior to examination of the selected welds. Drawings of the various cah"bration blocks used are contained in Appendix D .

  • 7

IlL

SUMMARY

OF EXAMINATIONS This section provides a discussion of the field data records and a summary of the NDE activities performed at Salem 1. A Explanation of Field Data Records The results of the examinations and calibrations performed by SwRI personnel were recorded on standard SwRI forms. Copies of these completed documents constitute Volumes III through V of this report. The original records will be retained in the SwRI Records Vault. The field data records for each weld or area are assembled in a package preceded by a summary sheet. The examination areas and summary sheet numbers correspond to those listed in the Nondestructive Examination Summary Table provided in Subsection B below. The instruments used in performing UT examinations were calibrated prior to use, then verified again at specified intervals during the examinations and upon completion of the examina-tions. The calibration parameters were recorded on the appropriate calibration record sheet as specified in the applicable NPOP. The documented calibration and calibration verification provide immediate assurance that the examinations were performed using properly calibrated instruments. The results of the examinations were recorded on the applicable data record sheets as specified in the Examination Plan. The information documented on these forms describes the parameters associated with those indications which were greater than the recording levels specified in the applicable NPOP .

  • The size, location, and nature of reflectors were determined by analyzing the indication parameters recorded on the forms described above. The analysis is documented on SwRI Indica-tion Resolution Record Sheets, which are included as part of each data package, when required.

B. Nondestructive Examination Summary Table The following section is the Nondestructive Examination Summary Table (Summary Table). The Summary Table lists the areas that were examined by SwRI personnel during this ISi. See Figure 1 for an explanation of the Summary Table format. Weld identification drawings depicting the location of Class 1 and *class 2 components are contained in Appendices A and B, respectively.

  • 9

DATE: SALEM NUCLEAR POWER STATION UNIT 1 PAGE: REVISION:

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERICO, FIRST OUTAGE (1992) CLASS 1 CC14PLETED CCl4PONENTS REACTOR PRESSURE VESSEL CLQS!JRE HEAD N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTI Fl CATION ITEM NO METHCO PROCEDURE c M R -CALIBRATION BLOCK** The remarks column Is ased to describe any pertinent or unique features of the

  • examination such as limitations, results, CNFs, etc. Ultrasonic calibration blocks are also listed In tilts column.

Tiie results of the examination are ladbted In these columns. The absence of ncordahle ladlcadoas Is sbOWD by an "X" ID the "NOREC" column. The presence

                                                                                        ~ u!trumafc lndlcztlom shown to be the
                                                                                        !'1!!9!! of e pomi:trfc f=:tun ot the eumt..tJon area Is ladlcated by an "X" In
  • dae "GEOM" column. The presence of aoapometrfc Indications Is Indicated by aa "X" In tbe "OTIIER" column. and an esplanatloa of the nature of each aoqeometrfc Indication Is cont:alned In da9 "REMARKS" column.

Tlda column Ilsa tile applicable SwRI nudear projects operadq procedan used ror the aamlnatlon. The NDE method used duriq the eumlaadoa ls lkted In tbJs column. The ASME SECTION XI ITEM NO. and CATEGORY of the eumlnadon uu an Usted In this co.hmm. Each evmtuadon area Is l1tted la this column. Details of the weld ldentlftcatJoa system are contained la Appeudk:es A and B. This column references the e:um!natlon mmmary sheet which serves u a cover sheet for the data package and llsm the data record numbers, dae eumillers, and any pertinent remarks. Figure 1. Explanation of Summary Table Format

  • 10

DATE: 08/27/92 SALEM NUCLEAR POWER STATION UNIT 1 PAGE: 11 REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 1 COMPLETED CCMPONENTS REACTOR PRESSURE yESS£L CLOSURE HEAD N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOO PROCEDURE C M R **CALIBRATION BLOCK** CLOSURE STUDS. NUTS. AND WASHERS CFIG NO A*2> 005200 1*RPV*STUDS 1*54 B*G*1 MT PSE*MT2/1 x EXAMINED 19 THROUGH 37. CLOSURE STUDS 86.30 , UT60 PSE*UT18/0 x UT88 x

                                                                                             **7*1.125*8*CS*60*SAM**

005310 1*RPV*NUTS 1*54 CLOSURE NUTS B*G*1 MT PSE*MT2/1 x - - EXAMINED NUTS ON STUDS 19 THROUGH 37.

86. 10 005400 1*RPV*WASHERS 1*54 B*G*1 VT PSE*VT1/0 X *
  • EXAMINED WASHERS ON STUDS 19 THROUGH 37 CLOSURE WASHERS 86.50
 *                                                                                                                         /

DATE: 08/27/92 SALEM NUCLEAR POWER STATION UNIT 1 PAGE: 12

  • l!EVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST CAJTAGE (1992) CLASS 1 COMPLETED COMPONENTS PRESSURIZER N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER !DENT! Fl CATION ITEM NO METHOD PROCEDURE c MR **CALIBRATION BLOCK** LONGITUDINAL WELDS CFIG NO A*3) 006100 1*PZR*2 B*B UTO\I PSE*UT49/1 x EXAMINED 12u OF WELD LENGTH INTERSECTING LONGITUDINAL WELD SHELL A B2.12 UT45 PSE*UT15/1 x CIRCUMFERENTIAL HEAD WELD. UT45T x UT60 x UT60T x **S*CSCL*42*SAM** 006325 1*PZR*20 B*B UTO\I PSE*UT49/1 x LIMITED EXAM DUE TO PRESSURIZER SUPPORT. LONGITUDINAL WELD SHELL J B2.12 UT45 KPSE*UT15/1 x EXAMINED 8*1/2u OF THE REQUIRED 12n. UT45T x UT60 x UT60T x **S*CSCL*42*SAM** CIRCUMFERENTIAL WELDS CFIG NO A*3> 1*PZR*1 B*B UTIN PSE*UT49/1 x EXAMINED FROM La26011 TO L=5 11 IJHICH IJAS LOWER HEAD TO SHELL A B2.11 UT45 PSE*UT15/1

  • x . . NOT EXAMINED IN 1989. TOTAL \JELD NOIJ UT45T x EXAMINED.

UT60 x . . UT60T x **S*CSCL*42*SAM** 006850 1*PZR*21 B*B UTIN PSE*UT49/1 x LIMITED EXAM DUE TO WELDED PAOS. SHELL J TO UPPER HEAD B2.11 UT45 PSE*UT15/1 x EXAMINED 99.98X IN ONE DIRECTION. UT45T, x EXAMINED 75.3X CCOE REQUIRED TIJO UT60 x DIRECTIONS. UT60T x **S*CSCL*42*SAM**

          'NOZZLE INSIDE RADIUS£!) §ECTION CFIG NO A*3) 007100 6*PRN*1103*IRS                     B*D       UT53       PSE*UT11/1        )( . .

RELIEF NOZZLE 83.120

                                                                                            **IR*CSCL*84*SAM**

007200 6*PRN*1104*1RS B*D UT53 PSE*UT11/1 x . . RELIEF NOZZLE B3.120

*                                                                                           **IR*CSCL*84*SAM**

DATE: 08/27/92 SALEM NUCLEAR PO\JER STATION UNIT 1 PAGE: REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOO,,FIRST OUTAGE <1992) CLASS 1 Cet4PLETEO COMPONENTS PRESSURIZER N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C M R **CALIBRATION BLOCK** NOZZLE INSIDE RADIUSED SECTION CFIG NO A-3) 007300 6*PRN*1105*IRS B*D UT53 PSE*UT11/1 X, -

  • RELIEF NOZZLE B3.120
                                                                                             **IR*CSCL*B4*SAM**

INTEGRALLY lo'ELDED SUPPORTS CFIG NO A*3> 007700 1*PZR*1VS B*H UT45 PSE*UT16/1 x EXAMINED FROM L=260 11 TO L=S 11 WHICH WAS LWR HEAD TO SUPPORT SKIRT 88.20 UT45T x NOT EXAMINED IN 1989. TOTAL WELD NO\J UT60 x EXAMINED.

                                                                                             **PL*1.5*CS*65*SAM**

DATE: 08/27/92 SALEM NUCLEAR POWER STATION UNIT 1 PAGE: 14

  • QEVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE C1992) CLASS 1 CCMPLETED CCMPONENTS CHEMICAL AND VOLUME CONTROL SYSTEM N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHCO PROCEDURE C M R **CALIBRATION BLOCK** 3*CV*1143 CFIG NO A*8) 012600 3*CV*1143*5 B*J PT PSE*PT1/0 x - - PIPE TO PIPE B9.21 012800 3*CV*1143*7 B*J PT PSE*PT1/0 x -

  • PIPE TO ELBOW B9.21 013000 3*CV*1143*9 PIPE TO ELBOW 9*J 99.21 PT PSE*PT1/0 x - -
  • 3*CV*1141 CFIG NO A*9) 015900 3*CV*1141*6 PIPE TO ELBOW 9*J 99.21 PT PSE*PT1/0 x - -

016700 3*CV*1141*.14 9*J PT PSE*PT1/0 x EXAMINED PER IE9 88*08. VALVE TO ELBOW 99.21 UT45 PSE*UT31/1 x UT45T x UT45TAN x

                                                                                         **3*SS*160*.451*30*SAM*'*

016800 3*CV*1141*15 9*J PT PSE*PT1/0 x EXAMINED PER IEB 88*08. UT45 ELBOW TO BRANCH CONNECTION B9.21 UT45 PSE*UT31/1 - x . INDICATIONS ARE GECMETRIC REFLECTORS UT45T x FROM THE WELD ROOT. UT45TAN x

                                                                                         **3*SS*160*.451*30*SAM*'*

3*CV*1133 CFIG NO A*10)

 . 017'900 3*CV*1133*11 PIPE TO ELBOW 9*J B9.21 PT          PSE*PT1/0         x   --

DATE: 08/27/92 SALEM NUCLEAR PO'WER STATION UNIT 1 PAGE: REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOO, FIRST OUTAGE (1992) CLASS 1 COMPLETED COMPONENTS CHEMICAL AND VOLUME CQNTROL SYSTEM N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK**

                                                                                 . . .    ************************************** I 3*CV*1133 CFIG NO A*10) 018300 3*CV*1133*15                     B*J      PT          PSE*PT1/0
  • x *
  • VALVE TO PIPE B9.21 2*CV*1175 CFIG NO A*11. A*12) 020500 2*CV*1175*20 B*J PT PSE*PT1/0 x *
  • PIPE TO ELBOW B9.40 021700 2*CV*1175*32 B*J PT PSE*PT1/0 x . .

PIPE TO ELBOW B9.40 022000 2*CV*1175*35 B*J PT PSE*PT1/0 x . . EXAMINED PER IEB 88*08. VALVE TO PIPE B9.40 UT45 PSE*UT39/1 x UT45T x . . UT70 x

                                                                                         **1.5*SS*COUP*111*SAM**

022100 2*CV* 1175*36 B*J PT PSE*PT1/0 x EXAMINED PER IEB 88*08. PIPE TO TEE. B9.21 UT45 PSE*UT39/1 x . . UT45T x UT70 x

                                                                                         **1.5*SS*COUP*111*SAM**

' SALEM NUCLEAR POWER STATION UNIT DATE: 08/27/92 PAGE: 16

 *    ~evlSION:      0                              

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 1 COMPLETED COMPONENTS PRESSURE RELIEF SYSTEM N 0 ASHE 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHCO PROCEDURE c MR **CALIBRATION BLOCK** 6*PR*1105 <FIG NO A*13) 022200 6*PR*1105*1 B-F PT PSE*PT1/0 . . x PT INDICATION IS CCOE ALLO\IABLE. SEE NOZZLE TO SAFE-ENO BS. 130 UT45 PSE-UT31/1 x - . CNF SAM1*7. ACCEPTED "AS IS" BY PSE&G UT45T UT45RL PSE*UT31/1 x x

                                                                                       -   - PERSONNEL.

UT45RLT x . - **6-SS-160-.764-25-SAM** 022300 6-PR-1105-2 B-J PT PSE*PT1/0 x UT45 INDICATION IS A GEOMETRIC REFLECTOR SAFE-END TO ELBOW 89. 11 UT45 PSE*UT31/1 - x . FRCJC THE llE LO ROOT

  • NO UT FRCJC THE UT45T x UPSTREAM SIDE DUE TO SAFE-ENO UT45TAN x CONFIGURTAT ION. OBTAINED 100% OF CODE REQUIRED COVERAGE.
                                                                                             **6-SS-160-.764*25-SAM**
 *-J200 6*PR*1105*11                        B-J        PT          PSE-PT1/0         x . -   PT PERFORMED AT REQUEST OF PSE&G AS PART ELBOW TO FLANGE                89.11                                            OF AN EXPANDED s*COPE DUE TO INDICATIONS ON 6-PR-1103*12.
                                                                                             **6-SS-160-.764-25-SAM**

6*PR*1104 CFIG NO A-14) 024400 6-PR* 1104* 11 B-J PT PSE-PT1/0 x . - PT PERFORMED AT REQUEST OF PSE&G AS PART ELBOW TO FLANGE 89.,, OF AN EXPANDED SCOPE DUE TO INDICATIONS ON 6*PR-1103*12.

                                                                                             **6-SS-160-.764-25-SAM**

6-PR-1103 CFIG NO A-15) 025700 6*PR*1103*12 B-J

  • PT PSE*PT1/0 - . x PT EXAM REVEALED ONE INDICATION WHICH ELBO\I TO FLANGE 89.11 PT x EXCEEDED CODE ALLOWABLE DIMENSION.

UT45 PSE*UT31/2 x REEXAMINATION AFTER SURFACE PREPARATION UT45T x REVEALED NO RECORDABLE INDICATIONS. SEE UT45TAN x CNF SAM1*6, 6A, 68 AND 6C.

                                                                                             **6*SS-160*.764-25-SAM**

CATE: 08/27/92 SALEH NUCLEAR POIJER STATION UNIT 1 PAGE: 17 REVISION: 0 SUHHARY OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERICO, FIRST CIJTAGE (1992) CLASS 1 Celo4PLETED COMPONENTS PRESSURIZING SYSTEM N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IOENTIFICATION ITEM NO METHOO PROCEDURE C M R **CALIBRATION BLOCK** 14*PS*1131 (FIG NO A*18) 029700 14-PS-1131*2 B*F PT PSE*PT1/0 x NO UT UPSTREAM OUE TO NOZZLE NOZZLE TO PIPE BS.130 UT45 PSE*UT31/2 x CONFIGURAT.ION. 100X OF COOE REQUIRED UT45T x COVERAGE OBTAINED. UT45TAN x

                                                                                     **14-SS-140-1.25-77-SAM**

DATE: 08/27/92 SALEM NUCLEAR PO\JER STATION UNIT 1 PAGE: 18 REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERICO, FIRST OUTAGE ( 1992) CLASS 1 CCJ4PLETED CCJ4PONENTS

  • REACTOR COOLANT SYSTEM N 0 ASME 0 Ci T SEC. XI R E H

SUMMARY

EXA141NATION AREA CATGY EXA14 E 0 E REMARKS NUMBER !DENT! Fl CATION ITEM NO MET HOO PROCEDURE c MR **CALIBRATION BLOCK** 31*RC*1130 CFJG NO A*24> 040100 31*RC*1130*3 B*J PT PSE*PT1/0 x ELBOW TO PIPE B9.11 UT45 PSE*UT31/2 x UT45T x UT45TAN x

                                                                                                  **2.312*SS*37*SAM**

31*RC*1120 CFIG NO A*25> 041900 31*RC*1120*2 B*F PT PSE*PT1/0 x NOZZLE TO ELBOW B5.130 UT45 PSE*UT31/2 x UT45T x UT45TAN x

                                                                                                 **2.312*SS*37*SAM**
  • 31*RC*1110 CFIG NO A*26>

044700 31-ltC* 1110*2 NOZZLE to ELBOW B*F 85.130 PT UT45 UT45T

  • PSE*PT1/0 SEE RMKS PSE*UT31/1 x

x NO UT45 & UT45TAN FROM UPSTREAM SIDE DUE TO NOZZLE CONFIGURATION OR FROM DOWNSTREAM SIDE DUE TO ACCOUSTIC UT45TAN SEE RMKS PROPERTIES OF ELBOW MATERIAL. EXAMINED FOR TRANSVERSE REFLECTORS ON THE WELD ONLY.

                                                                                                 **2.312*SS*37*SAM**

29*RC*1140 CFIG NO A*27> 048250 29*RC*1140*5 B*F PT PSE*PT1/0 x NO UT45 & UT45TAN FROM UPSTREAM SIDE DUE ELB!7tl TO NOZZLE 85.130 UT45 SEE RMICS TO ACCOUSTIC PROPERTIES OF ELBOW UT45T PSE*UT31/1 x MATERIAL OR FROM DOWNSTREAM SIDE DUE TO UT45TAN SEE RMICS NOZZLE CONFIGURATION. EXAMINED FOR TRANSVERSE REFLECTORS ON THE WELD ONLY.

                                                                                                **2.312*SS*37*SAM**

27.5*RC*1140 CFIG NO A*31> 054400 27.5*RC*1140*1 B*J PT PSE*PT1/0 x NO UT FROM THE UPSREAM SIDE DUE TO PUMP* PUMP TO PIPE 89.11 UT45 PSE*UT31/1 . x . CONF IGURA Tl ON. UT45 INDICATION IS A UT45T x GEOMETRIC REFLECTOR FROM THE WELD RCXJT. UT45TAN x

                                                                                                **2.312*SS*37*SAM**

DATE: DS/27/92 SALEM NUCLEAR PO\.IER STATION UNIT 1 ,, PAGE: REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERI~, FIRST OUTAGE (1992) CLASS 1 COMPLETED COMPONENTS REACTOR COOLANT SYSTI!! N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO MET HOO PROCEDURE c MR **CALIBRATION BLOCK** 27.5*RC*1140 CFIG NO A*312 054700 27.5*RC*1140*1/10*SJ*1141 B*J PT PSE*PT1/0 )( AUGMENTED EXAM FROM THE BRANCH 10 IN. BRANCH CONNECTION 89.31

  • UT45 PSE*UT31/2 )( CONNECTION SIDE. LIMITED UT. NO UT39.

UT45T )( ON WELD DUE TO CONTOUR. EXAMINED 74% UT39T )( THE REQUIRED TWO DIRECTIONS.

                                                                                                 **2.312*SS*37*SAM**

27.5*RC*1130 <FIG NO A*32> 056600 27.5*RC*1130.*2 B*J PT PSE*PT1/0 )( UT45 INDICATIONS ARE GEOMETRIC PIPE TO PIPE B9.11 UT45 UT45T PSE*UT31/1 -

                                                                                       )(
                                                                                           )(
                                                                                              - REFLECTORS FROM THE WELD ROOT.

UT45TAN )(

                                                                                                **2.312*SS*37*SAM**

27.5*RC*1110 <FIG NO A*34> 059100 27.S*RC*1110*1/4*PS*1111 B*J PT PSE*PT1/0 )( AUGMENTED EXAM FROM THE BRANCH

           ~4 IN. BRANCH CONNECTION         B9.31      UT45        PSE*UT31/2         )(        CONNECTION SIDE. LIMITED UT EXAM. NO UT45T                          )(        UT32T ON WELD DUE TO CONTOUR. EXA141NEI:

UT32T )( 87X OF THE COOE REQUIRED TWO DIRECTIONS

                                                                                                **2.312*SS*.37*SAM**

3*RC*1143 (FIG NO A-35> 061900 3*RC* 1143* 18 B*J PT PSE*PT1/0 )( CAP TO BRANCH CONNECTION 89.21

DATE: 08/27/92 SALEM NUCLEAR PO\JER STATION UNIT 1 PAGE: 20

   ~EVISION:      0                       

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 1 CCJ4PLETED CCJ4PONENTS RESIDUAL HEAT REMOVAL SYSTEM N 0 ASME 0 G T SEC. XI. R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOO PROCEDURE C M R **CALIBRATION BLOCK** 14-RH-1111 (FIG NO A-52> 092300 14*RH*1111*1/6*SJ*1111 B*J PT PSE*PT1/0 x EXAMINED FROM BOTH SIDES. 6 IN. BRANCH CONNECTION B9.31 UT45 PSE*UT31/2 x UT45T x

                                                                                    **14*SS*160*1.400*78*SAM**

093700 14*RH*1111*15 B*J PT PSE*PT1/0 X EXAMINED PER !EB 76*06. UT45 INDICATION PIPE TO ELBOW B9.11 UT45 PSE*UT31/2

  • X
  • IS A GECJ4ETRIC REFLRECTOR FROM THE llELD UT45T x ROOT.
                                                                                    **14*SS*160*1.400*78*SAM**

DATE: 08/27/92 SALEM NUCLEAR PO\JER STATION UNIT 1 PAGE: 2 REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXA.141NATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 1 CC>>4PLETED CCJllPONENTS SAFETY INJECTION SYSTEM N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEH NO METHOO PROCEDURE C M R **CALIBRATION BLOCK** 10*SJ*1121 <FIG NO A*56> 100300 10*SJ*1121*8PS B*K*1 PT PSE*PT1/0 x * - PENETRATION TO PIPE B10.10 100500 10*SJ*1121*10 B*J PT PSE*PT1/0 x EXAMINED PER !EB 76*06. UT45 ELBOW TO PIPE B9.11 UT45 PSE*UT31/2 - x - INDICATIONS ARE GECJllETRIC REFLECTORS UT45T x -- FRCJll THE lo'ELD ROOT. UT45TAN x --

                                                                                              **10*SS*160*1.119*22*SAM**

100800 10*SJ*1121*13 11-J PT PSE*PT1/0 x EXAMINED PER IEB 76*06. UT45 PIPE TO EL~ B9.11 UT45 PSE*UT31/2 - x - INDICATIONS ARE GECJllETRIC REFLECTORS UT45T x FRCJll THE lo'ELD ROOT. UT45TAN x

                                                                                              **10*SS*160*1.119*22*SAM**

101200 '10*SJ*1121*16/2*SJ*1129 B*J PT PSE*PT1/0 x - - 2 IN. BRANCH CONNECTION B9.32 10*SJ*1111 ~FIG NO A*57} 103700 10*SJ*1111-'18 B*J PT PSE*PT1/0 x UT45 INDICATION IS A GECJllETRIC REFLECTOf VALVE TO EL~ 89.11 UT45 UT45T PSE*UT31/2 -x x

                                                                                          -  FRCJll THE lo'ELD ROOT. NO UT FRCJll THE UPSTREAM SIDE DUE TO VALVE UT45TAN                          )(        COO FI GURA TI ON.
                                                                                             **10*SS*160*1.119*22*SAM**

8-SJ-1162 <FIG NO A-58; A-59) 107400 B*SJ-1162*28 B*J PT PSE*PT1/0 x - - UT45 INDICATIONS 1, 2, 4 AND 5 ARE PIPE TO PIPE 89.11 UT45 PSE*UT31/2 - x - GECJllETRIC REFLECTORS FRCJll THE WELD ROOT UT45T x INDICATIONS 3 AND 6 ARE CRO'JN GECJllETRY. UT45TAN x

                                                                                             **8*SS*XX*.860*23*SAH**

DATE: 08/27/92 SALEM NUCLEAR PO\JER STATION UNIT 1 PAGE: 22

  • ~EVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 1 COMPLETED COMPONENTS SAFETY INJECTION SYSTEM N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C M R **CALIBRATION BLOCK** 8*SJ*1162 <FIG NO A*58. A*59) 107700 8*SJ*1162*30PS B*K*1 PT PSE*PT1/0 x - - PIPE TO PENETRATION 810.10 8*SJ*1145 CFIG NO A*62) 111800 8*SJ*1145*3 PIPE TO PIPE B*J B9.11 PT UT45 PSE*PT1/0 PSE*UT31/1 x --

                                                                                   - x -

EXAMINED PER IEB 76*06. UT45 INDICATIONS ARE GEOMETRIC REFLECTORS UT45T x FROM THE WELD ROOT. UT45TAN x

                                                                                           **8*SS*XX*.860*23*SAM'**
          *6*SJ*1142 (FIG NO A*64)

.114300 6*SJ*1142*5 B*J PT PSE*PT1/0 x EXAMINED PER IEB 76*06. UT45 PIPE TO ELBOW 89.11 UT45 PSE*UT31/1 - x - INDICATIONS 1 AND 3 ARE GEOMETRIC UT45T x REFLECTORS FROM THE WELD ROOT. UT45TAN x . . INDICATION 2 IS A GEOMETRIC REFLECTOR FROM THE COUNTER BORE. *

                                                                                           **6*SS*160*.764*25*SAM'**

6*SJ*1141 (FIG NO A*65) 115300 6*SJ*1141*1 B*J PT PSE*PT1/0 x EXAMINED PER IEB 76*06. ONE LINEAR REDUCER TO ELBOW 89.11 PT x INDICATION. SEE CNF SAM1*9. REEXAM UT45 PSE*UT31/2 x . . AFTER WELD PREPARATION REVEALED NO UT45T x RECORDABLE INDICATIONS. UT4STAN x **6*SS*160*.764*25*SAM** 116400 6*SJ*1141*12 B*J PT PSE*PT1/0 x EXAMINED PER IEB 76*06. UT45 PIPE TO ELBOW 89.11 . UT45 PSE*UT31/2 . x . INDICATIONS ARE GEOMETRIC REFLECTORS UT45T x FROM THE WELD ROOT AND INSIDE SURFACE UT45TAN x COUNTER BORE AREA.

                                                                                           **6*SS*160*.764*25*SAM**

DATE: 08/27/92 SALEM NUCLEAR PO\JER STATION UNIT 1 PAGE: z: REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 1 COMPLETED CCJIPONENTS SAFETY INJECTION SYSTI!! N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTI Fl CATION ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** 6*SJ*1131 CFIG NO A*67> 119800 6*SJ*1131*10 B*J PT PSE*PT1/0 x EXAMINED PER !EB 76*06. UT45 PIPE TO ELBOW B9. 11 UT45 PSE*UT31/2 . x . INDICATIONS ARE GECJIETRIC REFLECTORS UT45T x . . FRCJI TH.E WELD ROOT. UT45TAN x . .

                                                                                                  **6*SS*160*.764*25*SAM**

120600 6*SJ*1131*18 B*J PT PSE*PT1/0 x . . EXAMINED PER IEB 76*06. ELBOW TO VALVE B9.11 UT45 PSE*UT31/2 x . . UT45T x UT45TAN x

                                                                                                 **6*SS*160*.764*25*SAM**

6*SJ*1122 CFIG NO A*68> 122100 6*SJ*1122*12 B*J PT PSE*PT1/0 x . . EXAMINED PER IEB 76*06. NO UT FRCJ4 THE PIPE TO TEE B9.11 UT45 PSE*UT31/2 x DOWNSTREAM SIDE DUE TO TEE UT45T UT45TAN x x

                                                                                         -. .. CONFIGURATION.
                                                                                                **6*SS*160*.764*25*SAM**

6*SJ*1112 CFIG NO A*70> 123600 ~-SJ*1112*9 B*J PT PSE*PT1/0 x EXAMINED PER IEB 76*06. UT45 PIPE TO EL8()(1 B9.11 UT45 PSE*UT31/2 . x . INDICATIONS ARE GECJIETRIC REFLECTORS UT45T x FRCJ4 THE WELD ROOT. UT45TAN x . .

                                                                                                **6*SS*160*.764*25*SAM**

6*SJ*1111 CFIG NO A*71> 124100 6*SJ*1111*1 B*J PT PSE*PT1/0 x EXAMINED PER IEB 76*06. UT45 REDUCER TO VALVE B9. 11 UT45 PSE*UT31/2 . x . INDICATIONS ARE GECJIETRIC REFLECTORS UT45T x . . FRCJI THE WELD ROOT. NO UT ON DOWNSTREA UT45TAN x SIDE DUE TO VALVE CONFIGURATION. LIMITED UT FRCJI THE UPSTREAM SIDE DUE T REDUCER. 100% COVERAGE OBTAINED.

                                                                                                **6*SS*160*.764*25*SAM**

DATE: 08/27/92 SALEM NUCLEAR PO\JER STATION UNIT 1 PAGE: 24 .EVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 1 COMPLETED COMPONENTS SAFETY INJECTION SYSTEM N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C M R **CALIBRATION BLOCK** 4-SJ-1194 CFIG NO A-73) 125100 4-SJ-1194-5 B-J PT PSE*PT1/0 X - - EXAMINED PER !EB 76-06. UT45 INDICATION PIPE TO ELBCN B9.11 UT45 PSE*UT31/1 - X - IS A GEOMETRIC REFLECTOR FROM THE WELD UT45T X - - ROOT. UT45TAN x

                                                                                        **4-SS-160-.533-28-SAM*R**

125700 4*SJ-1194-9 B-J PT PSE*PT1/0 X - - EXAMINED PER IEB 76*06. UT45 INDICATION PIPE TO ELBOW B9.11 UT45 PSE*UT31/1 - X - IS A GEOMETRIC REFLECTOR FROM THE WELD UT45T X * - ROOT. UT45TAN x

                                                                                        **4-SS*160*.533-28-SAM-R**

.S500 4-SJ-1194-17 B-J PT PSE-PT1/0 x EXAMINED PER IEB 76-06. ELBOW TO PIPE B9.11 UT45 PSE-UT31/1 x UT45T x UT45TAN x

                                                                                       **4-SS-160-.533-28*SAM-R**

3-SJ-1192 CFIG NO A-72> 135400 3-SJ-1192-12/1.5-SJ-1112 B-J PT PSE-PT1/0 x 1 1/2IN. BRANCH CONNECTION B9.32 2-SJ-1149 CFIG NO A-76. A-77) 136000 2-SJ-1149-2 B-J PT PSE-PT1/0 x - - PIPE TO FLANGE B9.40 137200 2-SJ-1149-13 B-J PT PSE-PT1/0 x - - TEE TO REDUCER B9.40

  • /

I

DATE: 08/27/92 SALEM NUCLEAR POIJER STATION UNIT 1 PAGE: 25 REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST CXJTAGE (1992) CLASS 1 COMPLETED COMPONENTS SAFETY INJECTION SYSTEM N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C M R **CALIBRATION BLOCK** 2*SJ*1149 CFIG NO A-76, A-77) 140000 2-SJ-1149*41 B*J PT PSE*PT1/0 x - - PIPE TO ELBO'J B9.40 140400 2-SJ-1149*45 B*J PT PSE*PT1/0 x - - Pl.PE TO ELBO'J B9.40 2*SJ*1147 (FIG NO A-78) 141100 2-SJ* 1147*5 B*J PT PSE-PT1/0 x - - ELBO'J TO PIPE B9.40 142400 2-SJ-1147*17 B*J PT PSE*PT1/0 x - - PIPE TO ELBO'J B9.40 2-SJ-1139 CFIG NO A-79) 143300 2-SJ-1139*1 B*J PT PSE*PT1/0 x - - REDUCING ELBPW TO PIPE B9.21 143900 2-SJ-1139*4 B*J PT PSE*PT1/0 x PIPE TO VALVE B9.40 145100 2-SJ-1139*16 B*J PT PSE-PT1/0 x - - ELBO'J TO PIPE B9.40

  • \..

DATE: 08/27/92 SALEM NUCLEAR PO\JER STATION UNIT 1 PAGE: 26 ~VISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERICO, FIRST OUTAGE (1992) CLASS 1 COMPLETED COMPONENTS SAFETY INJECTION SYSTEM N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHCO PROCEDURE C M R **CALIBRATION BLOCK** 2*SJ*1139 CFIG NO A*79) 146300 2*SJ*1139*28 B*J PT PSE*PT1/0 x *

  • ELBO'J TO PIPE B9.40 2*SJ*1137 CFIG NO A-80) 148100 2*SJ*1137*12 B*J PT PSE*PT1/0 . . x ONE LINEAR INDICATION. SEE CNF SAM1*1.

PIPE TO VALVE B9.40 PT x . . REEXAMINATION AFTER IJELD PREPARATION REVEALED NO RECORDABLE INDICATIONS. 149300 2*SJ*1137*24 B*J PT PSE*PT1/0 x ELBO'J TO PIPE B9.40 2*SJ*1129 CFIG NO A*81, A*82) 151000 2*SJ*1129*8 B*J PT PSE*PT1/0 x . . PIPE TO ELBOW B9.40 152300 2*SJ*1129*21 B*J PT PSE*PT1/0 x . . LIMITED EXAM DUE TO PROXIMITY OF PIPE TO ELBOW B9.40 ADJACENT PIPING. EXAMINED 84X OF REQUIRED AREA. 153500 2*SJ*1129*33 B*J PT PSE"PT1/0 x . . PIPE TO COUPLING B9.40 154300 2*SJ*1129*41 B*J PT PSE*PT1/0 x *

  • PIPE TO ELBOW B9.40

DATE: 08/27/92 SALEM NUCLEAR PO\IER STATION UNIT 1 PAGE: 27 REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 1 COMPLETED COMPONENTS SAFETY INJECTION SYSTEM N 0 ASHE 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C M R **CALIBRATION BLOCK** 2*SJ*1129 (FIG NO A-81, A*82) 154700 2-SJ-1129-45 B*J PT PSE*PT1/0 x - - PIPE TO COUPLING B9.40

         . 2*SJ*1128 (FIG NO A-83,84,85) 155300 2*SJ*1128*1B                      B*J      PT          PSE*PT1/0         x - -

COUPLING TO PIPE 89.40 156600 2-SJ-1128*13 8*J PT PSE*PT1/0 x - - PIPE TO ELBO'J 89.40 158000 2-SJ-1128*27 B*J PT PSE*PT1/0 x . - COUPLING TO PIPE 89.40 160300 2-SJ-1128-49 B*J PT PSE*PT1/0 x - - COUPLING TO PIPE 89.40 161500 2*SJ*1128*61 B*J PT PSE*PT1/0 x - - PIPE TO ELBOW 89.40 162300 . 2-SJ* 1128*69 8*J PT PSE*PT1/0 x - - COUPLING TO PIPE 89.40 2-SJ-1119 <FIG NO A*86) 163800 2*SJ*1119*9 B*J PT x - - PSE*PT1/0 ELBO'J TO PIPE 89.40 I I

DATE: D8/27/92 SALEM NUCLEAR POWER STATION UNIT 1 PAGE: 28 .EVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 1 COMPLETED COMPONENTS SAFETY INJECTION SYSTEM N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C M R **CALIBRATION BLOCK** 2*SJ-1119 <FIG NO A-86> 165000 2*SJ*1119*21 B-J PT PSE*PT1/0 x - - PIPE TO ELBOW B9.40 2-SJ-1118 (FIG NO A-87, A*SS) 165400 2-SJ-1118*1 8*J PT PSE*PT1/0 x - - REDUCER TO PIPE B9.21 166700 2-SJ-1118*13 8-J PT PSE*PT1/0 x - - PIPE TO ELBOW 89.40 167900 2-SJ-1118-25 8*J PT PSE*PT1/0 x - - ELBOW TO PIPE 89.40 169100 2-SJ-1118-37 B*J PT PSE*PT1/0 x - - COUPLING TO PIPE B9.40 169800 2-SJ-1118*44 B*J PT PSE-PT1/0 x - - TEE TO PIPE B9.40 1.5-SJ-1142 (FIG NO A-89,90,91) 170400 1 1/2*SJ*1142*5 B*J PT PSE*PT1/0 x PIPE TO ELBOW 89.40

DATE: 08/27/92 SALEM NUCLEAR POUER STATION UNIT 1 PAGE: 29 REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERICO, FIRST OUTAGE (1992) CLASS 1 COMPLETED COMPONENTS SAFETY INJECTION SYSTEM N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGy EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C M R **CALIBRATION BLOCK** 1.5-SJ-1142 CFIG NO A-89.90.91) 171700 1 1/2-SJ-1142-17 B-J PT PSE-PT1/0 x - - ELBO'J TO PIPE B9.40 172900 1 1/2-SJ-1142-29 B-J PT PSE-PT1/0 x - - PIPE TO ELBO'J B9.40 174400 1 1/2-SJ-1142-44 B-J PT PSE-PT1/0 x - - PIPE TO ELBO'J B9.40

  • 175000 1 1/2"SJ-1142-50 VALVE TO PIPE B-J B9.40 PT UT45 UT45T UT70 PSE-PT1/0 PSE-UT39/1 x

x x x EXAMINED PER !EB 88-08.

                                                                                        **1.5-SS-COUP-111-SAM**

175100 1 1/2-SJ-1142-51 B-J PT PSE-PT1/0 x EXAMINED PER !EB 88-08. PIPE TO ELBO'J B9.40 UT45 PSE-UT39/1 x UT45T x - - UT70 x

                                                                                        **1.5-SS-COUP-111-SAM**

175200 1 1/2-SJ-1142-52 B-J PT PSE-PT1/0 x EXAMINED PER IEB 88-08. ELBO'J TO PIPE B9.40 UT45 PSE-UT39/1 x UT45T x UT70 x - -

                                                                                        **1.5-SS-COUP-111-SAM**

175300 1 1/2-SJ-1142-53 B-J PT PSE-PT1/0 x EXAMINED PER !EB 88-08. PIPE TO BRANCH CONNECTION B9.40 UT45 PSE-UT39/1 )( UT45T )( UT70 x

                                                                                        **1.5-SS-COUP-111-SAM**

DATE: 08/27/92 SALEM NUCLEAR PO\JER STATION UNIT 1 PAGE: 30 .VISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 1 COMPLETED COMPONENTS SAFETY INJECTION SYSTEM N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C M R **CALIBRATION BLOCK** 1.S*SJ-1132 CFIG NO A*92. A*93> 176200 1 1/2*SJ*1132*9 B*J PT PSE*PT1/0 x * - PIPE TO ELBOW B9.40 177500 1 1/2*SJ*1132*19 B*J PT PSE*PT1/0 x - - PIPE TO TEE B9.40 179600 1 1/2-SJ-1132*40 B*J PT PSE*PT1/0 . - x EXAMINED PER !EB 88*08. PT EXAM VALVE TO PIPE B9.40 PT x REVEALED ONE INDICATION WHICH EXCEEDED UT45 PSE*UT39/1 x CODE ALLOWABLE DIMENSIONS. SEE CNF x UT45T SAM1 *8. REEXAMINATION AFTER SURFACE UT70 x - - PREPARATION REVEALED NO RECORDABLE INDICATIONS.

                                                                                        **1.S*SS*COUP*111*SAM**

179700 1 1/2*SJe1132*41 B*J PT PSE*PT1/0 x EXAMINED PER IEB 88-08. PIPE TO ELBOW B9.40 UT45 PSE*UT39/1 x UT45T x UT70 x

                                                                                        **1.5-SS*COUP*111*SAM**

179800 1 112~sJ-1132*42 B*J PT PSE*PT1/0 x EXAMINED PER IEB 88-08. ELBOW TO PIPE 89.40 UT45 PSE*UT39/1 x UT45T x UT70 x

                                                                                        **1.S*SS*COUP*111*SAM**

179900 1 1/2-SJ-1132*43 B*J PT PSE*PT1/0 x EXAMINED PER IEB 88*08. PIPE TO BRANCH CONNECTION B9.40 UT45 PSE*UT39/1 x UT45T x UT70 x

                                                                                        **1.S*SS*COUP-111-SAM**

DATE: 08/27/92 SALEH NUCLEAR PO\.IER STATION UNIT 1 PAGE: 31 REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERICO, FIRST OUTAGE (1992) CLASS 1 CO>IPLETED COMPONENTS SAFETY INJECTION SYSTEM N 0 ASHE 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C M R **CALIBRATION BLOCK** 1.5*SJ*1122 CFIG NO A-94. A-95) 180100 1 1/2-SJ-1122*2 B*J PT PSE-PT1/0 x - - ELBOW TO PIPE B9.40 180700 1 1/2-SJ-1122*5 B-J PT PSE-PT1/0 x * - PIPE TO TEE B9.40 181400 1 1/2-SJ-1122-11 B-J PT PSE*PT1/0 x - - ELBOW TO PIPE B9.40

  • 183800 1 1/2-SJ-1122-33 PIPE TO COUPLING B-J B9.40 PT PSE-PT1/0 x . -

184800 1/2-SJ-1122-43 B*J PT PSE*PT1/0 x EXAMINED PER !EB 88*08. VALVE TO PIPE B9.40 UT45 PSE-UT39/1 x UT45T x - - UT70 x

                                                                                               **1.5-SS*COUP-111-SAM**

184900 1/2-SJ-1122-44 B*J PT PSE-PT1/0 x - - EXAMINED PER. !EB 88-08. PIPE TO ELBOW B9.40 UT45 PSE-UT39/1 x - - UT45T )( - . UT70 x - -

                                                                                               **1.5-SS*COUP-111-SAM**

185000 1 1/2-SJ-1122-45 B-J PT PSE-PT1/0 x EXAMINED PER !EB 88*08. ELBOW TO PIPE 89.40 UT45 PSE*UT39/1 x UT45T x UT70 x

                                                                                               **1.5-SS*COUP-111-SAM**

DATE: 08/27/92 SALEM NUCLEAR PO\IER STATION UNIT 1 PAGE: 32 ~VISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 1 COMPLETED COMPONENTS SAFETY INJECTION SYSTEM N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER !DENT! FICATION ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** 1.5-SJ-1122 CFIG NO A-94. A*95) 185100 1 1/2*SJ*1122*46 B*J PT PSE*PT1/0 x EXAMINED PER IEB 88*08. PIPE TO BRANCH CONNECTION B9.40 UT45 PSE*UT39/1 x - - UT45T x - - UT70 x

                                                                                            **1.5-SS*COUP-111-SAM**

1.5-SJ-1112 (FIG NO A*96. A*97) 185800 1 1/2*SJ*1112*7 B*J PT PSE*PT1/0 x - - PIPE TO FLANGE B9.40 1 1/2*SJ*1112*12 B*J PT PSE*PT1/0 x - - ELBOW TO PIPE B9.40 187100 1 1/2*Sa*1112*19 B*J PT PSE*PT1/0 x - - PIPE TO TEE B9.40 188300 1 1/2-SJ-1112-31 B*J PT PSE*PT1/0 x - - ELBOW TO PIPE B9.40 189500 1 1/2*SJ*1112*43 B*J PT PSE*PT1/0 x - - ELBOW TO PIPE B9.40 190200 1 1/2*SJ*1112*50 B*J PT PSE*PT1/0 X *

  • EXAMINED PER IEB 88*08.

VALVE TO PIPE B9.40 UT45 PSE*UT39/1 x UT45T x UT70 x

                                                                                           **1.5*SS*COUP*111*SAM**

DATE: 08/27/92 SALEH NUCLEAR PO\JER STATION UNIT 1 PAGE: 33 REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 1 COMPLETED COMPONENTS SAFETY INJECTION SYSTEM N 0 ASHE 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C M R **CALIBRATION BLOCK** 1.5-SJ-1112 CFIG NO A-96, A-97) 190300 1 1/2-SJ-1112*51 B*J PT PSE*PT1/0 x - - EXAMINED PER !EB 88-08. PIPE TO ELBC\J B9.40 UT45 PSE*UT39/1 x - - UT45T x - - UT70 x

                                                                                         **1.5*SS-COUP*111*SAM**

190400 1 1/2-SJ-1112*52 B-J PT PSE*PT1/0 x EXAMINED PER !EB 88*08. ELBC\J TO PIPE B9.40 UT45 PSE*UT39/1 x UT45T x - - UT70 x

                                                                                         **1.5-SS-COUP-111-SAM**
  • 190500 1 1/2-SJ-1112*53 PIPE TO BRANCH CONNECTION B*J B9.40 PT UT45 UT45T UT70 PSE*PT1/0 PSE*UT39/1 x

x x x EXAMINED PER !EB 88*08.

                                                                                         **1.5-SS-COUP-111-SAM**

DATE: 08/27/92 SALEM NUCLEAR PO\IER STATION UNIT 1 PAGE: 34 .VISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERICO, FIRST CXJTAGE (1992) CLASS 1 COMPLETED COMPONENTS REACTOR COOLANT PUMP 11 N 0 ASME 0 G T sec. x1 R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C M R **CALIBRATION BLOCK** BOLTING CFIG NO A*98) 190800 11*PMP*BOLTS 1*24 (IN PLACE) B*G*1 UT60 PSE*UT18/0 x NO EXAM ON BOLTS 3, 4, 5, 6, 13, 22, AND B6.180 UT88 x 23 DUE TO OBSTRUCTIONS FRCl4 OIL PANS, eve AND INSTRUMENT LINES.

                                                                                         **4.5*.75*8*CS*70*SAM**

PUMP MOTOR FLYWHEEL (FIG NO A*98) 191300 11*PMP*FLW UTOL PSE*UT6/1 x FLYWHEEL EXAMINED IN PLACE IN ACCORDANCE PUMP MOTOR FLYWHEEL RG1.14 UT45 (IN PLACE) x WITH REG. GUIDE 1.14. NO PT AND MT PERFORMED. LIMITED UT DUE TO BORE AND BOLT HOLES.

                                                                                         **S*CSCL*42*SAM/50*SAM**

DATE: 08/27/92 SALEM NUCLEAR PO\.IER STATION UNIT 1 PAGE: 35 REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERICO, FIRST OUTAGE (1992) CLASS 1 COMPLETED COMPONENTS REACTOR COOLANT PUMP 12 N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C M R **CALIBRATION BLOCK** BOLTING CFIG NO A-98) 191600 12-PMP-BOLTS 1*24 (IN PLACE) B-G-1 UT60 PSE-UT18/0 x NO EXAM ON BOLTS 3, 4, 5, 6, 7, 13, 14, B6.180 UT88 x AND 23 DUE TO OBSTRUCTIONS FROM OIL PANS, eve AND INSTRUMENT LINES.

                                                                                          **4.5-.75-8-CS-70-SAM**

PUMP MOTOR FLYWHEEL CFIG NO A-98) 192100 12-PMP*FLW UTOL PSE*UT6/1 x EXAMINED IN PLACE IN ACCORDANCE YITH 3S*76P917 RG1.14 UT45 CIN PLACE) x REG. GUIDE 1.14. NO PT AND MT PERFORMED. LIMITED UT DUE TO BORE AND BOLT HOLES.

                                                                                          **42-SAM/50-SAM**

DATE: 08/27/92 SALEM NUCLEAR PO\JER STATION UNIT 1 PAGE: 36 .EVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERICO, FIRST OUTAGE (1992) CLASS 1 COMPLETED COMPONENTS REACTOR COOLANT PUMP 14 N 0 ASHE 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOO PROCEDURE C M R **CALIBRATION BLOCK** BOLTING CFIG NO A*98) 193200 14*PHP*BOLTS 1*24 CIN PLACE) B*G*1 UT60 PSE*UT18/0 X *

  • NO EXAM ON BOLTS 1, 2, 13, 19, 22, 23, B6.180 UTBB X AND 24 DUE TO OBSTRUCTIONS FROM OIL PANS, eve AND INSTRUMENT LINES. NO EXAM ON BOLTS 3 AND 11 DUE TO OBSTRUCTIONS IN HEATER HOLES.
                                                                                        **4.5*.75*8*CS*70*SAM**

DATE: D8/27/92 SALEM NUCLEAR PO\JER STATION UNIT 1 PAGE: 37 REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 2 COMPLETED COMPONENTS STEAM GENERATOR 12 N 0 ASHE 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C H R **CALIBRATION BLOCK** CIRCUMFERENTIAL WELDS (FIG NO A*5) 201500 12*STG*24 C-A UTOll PSE*UT49/1 x EXAMINED WELD PLUS 1T OF BASE MATERIAL TRANSITION CONE TO SHELL C C1 .10 UT45 PSE*UT15/1 x FROM L=540" TO L=25", L=156" TO L=196" UT45T x AND L=348 11 TO L=388 11 (120 11 ) . SPECIAL UT60 x EXAMINATION AT THE REQUEST OF PSE&G. UT60T X **PL*3*CS-51*SAH**

DATE: 08/27/92 SALEM NUCLEAR POl./ER STATION UNIT 1 PAGE: 38 .REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST CXJTAGE (1992) CLASS 2 COMPLETED COMPONENTS BORON INJECTION TANK N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHCO PROCEDURE C M R **CALIBRATION BLOCK** SUPPORTS CFIG NO B-108) 204490 1*BIT*VS*2 c-c MT PSE*MT1/0 X *

  • LIMITED EXAM DUE TO INSULATION SUPPORT SUPPORT AT 135 DEG. C3.10 RING. EXAMINED OVER 90% OF REQUIRED AREA
  • DATE: 08/27/92 SALEM NUCLEAR PO\IER STATION UNIT 1 PAGE: 39 REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERICO, FIRST OUTAGE (1992) CLASS 2 COMPLETED COMPONENTS FEEDWATER SYSTEM N 0 ASHE 0 G T sec. x1 R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** 14*BF*2131 CFIG* NO B*11l 210800 14-BF-2131*1 C*F-2 MT PSE*MT1/0 x NO UT FROM THE UPSTREAM SIDE DUE TO VALVE TO PIPE C5.51 UT45 PSE*UT41/1 x VALVE CONFIGURATION. 100X OF COOE UT45T x REQUIRED COVERAGE OBTAINED.

                                                                                        **14*CS*120*1.14*36*SAM**

211650 14*BF*2131*10PS c-c MT PSE*MT1/0 x - - PIPE SUPPORT C3.20 14*BF*2121 CFIG NO 8*12> 214700 14*BF*2121*1 C*F*2 MT PSE*MT1/0 x - - MT PERFORMED AT REQUEST OF PSE&G AS PART VALVE TO PIPE C5.51 OF AN EXPANDED SCOPE DUE TO INDICATION ON 34*MS*2121*2.

                                                                                       **14*CS*120*1.14*36*SAM**

214800 '14*BF*2121*2 C*F*2 MT PSE*MT1/0 x - - MT PERFORMED AT REQUEST OF PES&G AS PART PIPE TO ELBO'J C5.51 OF AN EXPANDED SCOPE DUE TO INDICATION* ON 34*MS*2121*2.

                                                                                       **14*CS*120*1.14*36*SAM**

214910 14*BF*2121*3~L-1 c-c MT PSE*MT1/0 x - - PIPE LUG C3.20 214920 14*BF*2121*3PL*2 c-c MT PSE*MT1/0 x - - PIPE LUG C3.20 214930 14*BF*2121*3PL*3 c-c MT PSE*MT1/0 X *

  • LIMITED EXAM DUE TO PROXIMITY OF PIPE LUG C3.20 PENETRATION. EXAMINED 26X OF REQUIRED
                                                                                     . AREA
  • DATE: DS/27/92 SALEM NUCLEAR POUER STATION UNIT 1 PAGE: 40

.VISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 2 COMPLETED COMPONENTS FEED~ATER SYSTEM N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO MET HOO PROCEDURE c M R **CALIBRATION BLOCK** 14*BF*2121 CFIG NO B*12) 214940 14*BF*2121*3PL*4 C*C MT PSE*MT1/0 x . - LIMITED EXAM DUE TO PROXIMITY OF PIPE LUG C3.20 PENETRATION AND ADJACENT PIPING. EXAMINED ax OF REQUIRED AREA. 215100 14*BF*2121*3PS*2 C*C MT PSE*MT1/0 x . . PIPE SUPPORT C3.20

DATE: 08/27/92 SALEM NUCLEAR PO'JER STATION UNIT 1 PAGE: 41

  • REVISION: 0 MAIN STEAM SYSTEM ASME

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERICO, FIRST OUTAGE (1992) SEC. XI CLASS 2 COMPLETED COMPONENTS N 0 G T R E H 0

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** 34-MS-2141 CFIG NO B-21> 2223DO 34-MS-2141*2 C*F-2 ~T PSE*MT1/0 - - x MT PERFORMED (EXPANDED SCOPE) DUE TO PIPE TO VALVE CS.51 MT x INDICATION ON 34-MS-2121*2. NO RECORDABLE INDICATIONS ~!THIN THE CODE REQUIRED EXAM AREA. EXAM REVEALED ONE LINEAR INDICATION OUTSIDE THE CODE REQUIRED EXAM AREA, ON ADJACENT VALVE BCJOY. SEE CNF SAM1*12.

                                                                                         **PL*3*CS-51-SAM**

34-MS-2131 CFIG NO B-22) 222700 34*MS*2131*1/8*MS*2133 C*F-2 MT PSE-MT1/0 x - - 8 IN. BRANCH CONNECTION CS.81 223200 34-MS*2131-1PL-1 c-c MT PSE*MT1/0 x - - LIMITED EXAM DUE TO INACCESS~BILITY. PIPE LUG C3.20 EXAMINED 90% OF REQUIRED AREA. 223300 34*MS*2131*1PL*2 c-c MT PSE*MT1/0 X *

  • LIMITED EXAM DUE TO INACCESSIBILITY.

PIPE LUG C3.20 EXAMINED 90% OF REQUIRED AREA. 223400 34*MS*2131*1PL*3 c-c MT PSE*MT1/0 x - - PIPE LUG C3.20 223500 34*MS*2131*1PL*4 c-c MT PSE*MT1/0 x - - PIPE LUG C3.20 223600 34*MS*2131*1PL*5 c-c MT PSE*MT1/0 x - - PIPE LUG C3.20

DATE: 08/27/92 SALEM NUCLEAR POl.'ER STATION UNIT 1 PAGE: 42 .EVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERICO, FIRST CXJTAGE (1992) CLASS 2 COMPLETED COMPONENTS MAIN STEAM SYSTEM N 0 ASHE 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOO PROCEDURE C M R **CALIBRATION BLOCK** 34*MS-2131 CFIG NO B-22) 223700 34-MS-2131-1PL-6 c-c MT PSE-MT1/0 x - - PIPE LUG C3.20 223800 34-MS-2131-1PL-7 c-c MT PSE-MT1/0 x - - PIPE LUG C3.20 224000 34-MS-2131-1PL-9 c-c MT PSE-MT1/0 x - - PIPE LUG C3.20 . 0 0 5 34-MS-2131-1PL-10 c-c MT PSE-MT1/0 x - - PIPE LUG C3.20 224010 34-MS-2131-1PL-11 c-c MT PSE-MT1/0 X - - LIMITED EXAM DUE TO INACCESSIBILITY. PIPE LUG C3.20 EXAMINED 90% OF REQUIRED AREA. 224015 34-MS-2131-1PL-12 c-c MT PSE-MT1/0 X - - LIMITED EXAM DUE TO INACCESSIBILITY. PIPE LUG C3.20 EXAMINED 90% OF REQUIRED AREA. 224020 34-MS-2131-1PL-13 c-c MT PSE*MT1/0 x - - PIPE LUG C3.20 224025 34-MS-2131-1PL-14 c-c MT PSE-MT1/0 x - - PIPE LUG C3.-20

DATE: D8/27/92 SALEM NUCLEAR PO\JER STATION UNIT 1 PAGE: 43

  • REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 2 COMPLETED COMPONENTS MAIN STEAM SYSTEM N 0 ASHE 0 G T sec. x1 R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** 34*MS*2131 CFIG NO B*22) 224030 34*MS*2131*1PL-15 C*C MT PSE*MT1/0 x * - PIPE LUG C3.20 224035 34-MS-2131-1PL-16 c-c MT PSE-MT1/0 x - - PIPE LUG C3.20 224040 34-MS-2131-1PL-17 c-c MT PSE-MT1/0 x - - PIPE LUG C3.20

  • 224045 34-MS-2131-1PL-18 PIPE LUG c-c C3.20 MT PSE-MT1/0 x - -

224050 34-MS-2131-1PL-19 c-c MT PSE-MT1/0 - - x ONE CODE ALLOWABLE INDICATION. SEE CNF PIPE LUG C3.20 SAM1-10. ACCEPTED "AS IS" BY PSE&G PERSONNEL. 224055 34-MS-2131-1PL-20 c-c MT PSE-MT1/0 x - - PIPE LUG C3.20 224060 34-MS-2131-1PL-21 c-c MT PSE-MT1/0 X - - LIMITED EXAM DUE TO INACCESSIBILITY. PIPE LUG C3.20 EXAMINED 90% OF REQUIRED AREA. 224100 34-MS-2131-2 C-F-2 MT PSE-MT1/0 X - - MT PERFORMED AT REQUEST OF PSE&G AS PART PIPE TO VALVE C5.51 UT OF AN EXPANDED SCOPE DUE TO INDICATION ON 34-MS-2121-2.

                                                                                   **PL-3-CS-51-SAM**

DATE: 08/27/92 SALEM NUCLEAR PO\JER STATION UNIT 1 PAGE: 44 .VISION: -0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 2 COMPLETED COMPONENTS MAIN STEAM SYSTEM N 0 ASHE 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER !DENT! FI CATION ITEM NO METHOD PROCEDURE c M R **CALIBRATION BLOCK** 34*MS*2121 CFIG NO B-23) 225700 34-MS-2121*2 C*F-2 MT PSE-MT1/0 - - x MT REVEALED ONE INDICATION WHICH PIPE TO VALVE C5.51 MT x EXCEEDED CODE ALLO\IABLE DIMENSIONS. SEE UT45 PSE*UT41/1 - x - CNF'S SAM1*11, 11A & B. REEXAM AFTER UT45T x MECHANICAL REMOVAL OF INDICATllON REVEALED NO RECORDABLE INDICATIONS. UT45 INDICATIONS ARE GEOMETRIC REFLECTORS FROM THE INSIDE SURFACE.

                                                                                          **PL-3-CS-51-SAM**

34-MS-2111 CFIG NO B-24) 227500 34-MS-2111*2 C-F-2 MT PSE-MT1/0 x - - MT PERFORMED AT REQUEST OF PSE&G AS PART PIPE TO VALVE C5.51 UT OF AN EXPANDED SCOPE DUE TO INDICATION

  • 32-MS-2131 CFIG NO B-26)

ON 34-MS-2121*2.

                                                                                          **PL-3-CS-51-SAM**

228800 32*MS-2131-2PS*1 c-c MT PSE-MT1/0 x - - PIPE SUPPORT C3.20 228900 32-MS*2131-2PS-2 c-c MT PSE-MT1/0 x - - LIMITED EXAM DUE TO PIPE RESTRAINTS AND PIPE SUPPORT C3.20 INSTRUMENTATION LINES. EXAMINED 35.4% OF REQUIRED AREA. 30-MS-2131 CFIG NO B-26> 236400 30-MS-2131-8 C*F*2 MT PSE*MT1/0 x UT45 INDICATION IS A GEOMETRIC REFLECTOR PIPE TO ELBO\I C5.51 UT45 PSE*UT41/1 - x - FROM THE ID SURFACE. UT45T x

                                                                                          **PL-1.5-CS-65-SAM**

236420 30-MS-2131*8LD*I C-F-2 MT PSE*MT1/0 x 2.5T (3.75 11 ) OF WELD LENGTH REQUIRED. LONGITUDINAL C5.52 UT45 PSE*UT41/1 x EXAMINED 12 11 OF WELD LENGTH. UT45T x - -

                                                                                          **PL-1.5-CS-65-SAM**

DATE: 08/27/92 SALEM NUCLEAR PO\.IER STATION UNIT 1 PAGE: 45 REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 2 COMPLETED COMPONENTS

DATE: 08/27/92 SALEM NUCLEAR PO\JER STATION UNIT 1 PAGE: 46 EVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS

  • SECOND INTERVAL, SECOND PERICO, FIRST OUTAGE (1992)

CLASS 2 COMPLETED COMPONENTS CONTAINMENT SPRAY SYSTEM N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOO PROCEDURE C M R. **CALIBRATION BLOCK** a-cs-2027 AND S*CS-2029 CFIG NO B-60) 264224 8*CS*2027*1 C*F-1 PT PSE*PT1/0 x *

  • PUMP TO PIPE UT45 PSE*UT35/0 x -
  • UT45T x UT45TAN x * *
                                                                                         **8*SS*40-.330*44*SAM**

264234 a-cs-2029-2 C*F*1 PT PSE*PT1/0 x * . PIPE TO ELBOW UT45 PSE*UT35/0 x * . UT45T x *

  • UT45TAN x
                                                                                         **8*SS*40*.330*44*SAM**

DATE: 08/27/92 SALEM NUCLEAR PO\JER STATION UNIT 1 PAGE: 47 REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 2 COMPLETED COMPONENTS N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C M R **CALIBRATION BLOCK** 274200 12 MS 167 USS C-D UTO PSE*UT36/1 X - - EXAMINED ALL STUDS. UPPER SET STUDS ON LINE C4.40 34-MS-2121

                                                                                         **2.563-8-12-MSIV-82-SAM**

274400 12 MS 167 LSS LOWER SET STUDS ON LINE C-D UTO PSE*UT36/1 x - - EXAMINED ALL STUDS. C4.2 34-MS-2121

                                                                                         **2.563*8*12-MSIV-82-SAM**
  • WELDED SUPPORT CFIG NO B-28) 2moo 11 MS 167 vs-1 VALVE SUPPORT AT 90 DEG c-c C3.40 MT PSE*MT1/0 x - -

2m40 11 MS 167 VS*1A c-c MT PSE*MT1/0 x - - VALVE SUPPORT AT 90 DEG C3.40 2m60 11 MS 167 VS*1B c-c MT PSE*MT1/0 x - - VALVE SUPPORT AT 90 DEG C3.40 277800 11 MS 167 VS-2 c-c MT PSE*MT1/0 x - - VALVE SUPPORT AT 270 DEG C3.40 277840 11 MS 167 VS*2A c-c MT PSE*MT1/0 x - - VALVE SUPPORT AT 270 DEG C3.40

DATE: 08/27/92 SALEM NUCLEAR PO'JER STATION UNIT 1 PAGE: 48 .REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERICO, FIRST CXJTAGE (1992) CLASS 2 COMPLETED COMPONENTS illlli N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C M R **CALIBRATION BLOCK** WELDED SUPPORT CFIG NO B-28) 277860 11 MS 167 VS-2B c-c MT PSE-MT1/0 x - - VALVE SUPPORT AT 270 DEG C3.40 llELDED SUPPORT 277900 12 MS 167 VS-1 c-c MT PSE-MT1/0 x - - VALVE SUPPORT AT 90 DEG C3.40 277940 12 MS 167 VS-1A c-c MT PSE-MT1/0 x - - VALVE SUPPORT AT 90 DEG C3.40

  • 277960 12 MS 167 VS-18 VALVE SUPPORT AT 90 DEG c-c C3.40 MT PSE*MT1/0 x - - LIMITED EXAM DUE TO SURROUNDING SUPPORT STRUCTURES. EXAMINED 64X OF THE REQUIRED AREA.

278000 12 MS 167 VS-2 c-c MT PSE*MT1/0 x - - VALVE SUPPORT AT 270 DEG C3.40 278040 12 MS 167 VS*2A c-c MT PSE-MT1/0 x - - VALVE SUPPORT AT 270 DEG C3.40 278060 12 MS 167 VS-28 c-c MT PSE*MT1/0 x - - VALVE SUPPORT AT 270 DEG C3.40

DATE: 08/27/92 SALEM NUCLEAR PO\.IER STATION UNIT 1 PAGE: 49

  • REVISION: 0 CONTAINMENT SPRAY ASHE sec. x1

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 2 COMPLETED COMPONENTS N 0 0 G T R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO MET HOO PROCEDURE c M R **CALIBRATION BLOCK** 8*CS*2123 (FIG NO B*63) 353nO 8*CS*2123*2 C*F*1 PT PSE*PT1/0 x PIPE TO ELBOW C5.11 UT45 PSE*UT35/0 x - - UT45T x - -

                                                   .uT45TAN                        x
                                                                                          **8*SS*40*.330*44*SAM**

353740 S*CS-2123*3 C*F*1 PT PSE*PT1/0 x ELBOW TO PIPE CS.11 UT45 PSE*UT35/0 x UT45T x - - UT45TAN x

                                                                                          **8*SS*40*.330*44*SAM**
  • 8*CS*2114 CFIG NO B*66>

355440 S*CS-2114*3 ELBOW TO PIPE C*F*1 cs. 1.1 PT UT45 UT45T UT45TAN PSE*PT1/0 PSE*UT35/0 x x x x

                                                                                          **8*SS*40*.330*44*SAM**

DATE: 08/27/92 SALEM NUCLEAR PO\.IER STATION UNIT 1 PAGE: 50 ~EVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST CXJTAGE (1992) CLASS 2 CC>>4PLETED CC>>4PONENTS CHEMICAL & VOLUME CONTROL N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C M R **CALIBRATION BLOCK** 2-CV-2186 CFIG NO B-80) 365920 2-CV-2186-22 C*F-1 PT PSE-PT1/0 x - - CCXJPLING TO NOZZLE CS.30 2-CV-2161 CFIG NO B-84> 369380 2-CV-2161-20 C-F-1 PT PSE-PT1/0 x - - ELBO\.I TO PIPE CS.30 2-CV-2147 ~FIG NO B-85l . 0 0 0 2-CV-2147-1 C-F-1 PT PSE-PT1/0 x - - VALVE TO PIPE CS.30 370020 2-CV-2147-2 C-F-1 PT PSE-PT1/0 x - - PIPE TO TEE CS.30 370120 2-CV-2147-7 C-F-1 PT PSE-PT1/0 x - - PIPE TO VALVE CS.30 370140 2-CV-2147-8 C-F-1 PT PSE-PT1/0 x - - VALVE TO PIPE CS.30 370260. 2-CV-2147-14 C-F-1' PT PSE-PT1/0 - - X PT EXAM REVEALED ONE LINEAR INDICATION PIPE TO ELBO\.I CS.30 PT X - - WHICH EXCEEDED CODE ALLO\.IABLE DIMENSIONS. SEE CNF SAM1-4. REEXAMINATION AFTER WELD PREPARATION REVEALED NO RECORDABLE INDICATIONS

  • DATE: 08/27/92 SALEM NUCLEAR POWER STATION UNIT 1 PAGE: 51 REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERICO, FIRST OUTAGE (1992) CLASS 2 COMPLETED COMPONENTS CHEMICAL & VOLUME CONTROL N 0 ASME 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER !DENT! Fl CATION ITEM NO METHOO PROCEDURE C M R **CALIBRATION BLOCK** 2-CV-2147 CFIG NO B-85> 370280 2-CV-2147-15 C-F-1 PT PSE*PT1/0 x * - ELBOW TO PIPE C5.30

DATE: 08/27/92 SALEM NUCLEAR POWER STATION UNIT 1 PAGE: 52 .EVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERICO, FIRST ctJTAGE (1992) CLASS 2 Cai!PLETEO COMPONENTS SAFETY INJECTION N 0 ASHE 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO MET HOO PROCEDURE c MR **CALIBRATION BLOCK** 4-SJ-2150 CFIG NO B-59) 380000 4-SJ-2150*1 C-F-1 PT PSE*PT1/0 x - - REDUCER TO PIPE C5.21 UTOL PSE*UT31/1 x - - UT45 x - - UT4ST x - - UT45TAN x **4-SS-160-.533*28-SAM*R** 380240 4-SJ-2150-13 C*F* 1 PT PSE*PT1/0 x - - TEE TO PIPE C5.21 UTOL PSE*UT31/1 x UT45 x UT45'T x UT45TAN x **4-SS-160-.533-28-SAM*R** . 2 6 0 4-SJ-2150-14 C*F-1 PT PSE*PT1/0 - - x PT EXAM REVEALED ONE CODE ALLOWABLE PIPE TO VALVE C5.21 PT x INDICATION. SEE CNF SAM1*5. UT SEE RMKS REEXAMINATION AFTER IJELD PREPARATION REVEALED NO RECORDABLE INDICATIONS. UT EXAM SUBSTITUTED ~ITH 4-Sl-2150-13 DUE TO PERMANENT PIPE SUPPORT.

                                                                                            **4-SS-160-.533-28-SAM*R**

2-SJ-2160 (FIG NO B-103) 385860 2-SJ-2160*9 C-F-1 PT PSE*PT1/0 - - x PT EXAM REVEALED ONE CODE ALLOWABLE PIPE TO ELBOW C5.30 PT x - - INDICATION. SEE CNF SAM1*3. REEXAMINATION AFTER IJELD PREPARATION REVEALED NO RECORDABLE INDICATIONS. 385880 2-SJ-2160-10 C*F-1 PT PSE-PT1/0 - - x PT EXAM REVEALED T\JO LINEAR INDICATIONS. ELBOW TO PIPE C5.30 PT x SEE CNF SAM1*2. REEXAMINATION AFTER IJELD PREPARATION REVEALED NO RECORDABLE INDICATIONS. 2-SJ-2123 (FIG NO B-105) 387280 2-SJ-2123-15 C*F-1 PT PSE*PT1/0 x - - PIPE TO VALVE C5.30

I I I I DATE: 08/27/92 SALEM NUCLEAR POWER STATION UNIT 1 PAGE: 53 REVISION: 0

SUMMARY

OF NONDESTRUCTIVE EXAMINATIONS SECOND INTERVAL, SECOND PERIOD, FIRST OUTAGE (1992) CLASS 2 COMPLETED COMPONENTS SAFETY INJECTION N 0 ASHE 0 G T SEC. XI R E H

SUMMARY

EXAMINATION AREA CATGY EXAM E 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C M R **CALIBRATION BLOCK** 2-SJ-2123 CFIG NO B-105) 387300 2-SJ-2123-16 C-F-1 PT PSE-PT1/0 x - - VALVE TO PIPE CS.30 387320 2-SJ-2123-17 C-F-1 PT PSE-PT1/0 x - - PIPE TO ELBOW CS.30

APPENDIXG CUSTOMER NOTIFICATION FORMS Table of Contents CNF No. Area lndication(s) Opened Closed SAM 1-1 2-SJ-1137-12 7/32-inch linear 4/10/92 4/14/92 Pipe to Valve indication on base material of pipe SAM 1-2 2-SJ-2160-10 Two linear indications, 4/14/92 4/17/92 Elbow to Pipe one 3/8 inch, one 9/32 inch on base material of elbow SAM 1-3 2-SJ-2160-9 1/8-inch linear indication 4/14/92 4/18/92 Pipe to Elbow on base material of elbow SAM 1-4 2-CV-2147-14 3/8-inch linear indication 4/15/92 4/29/92 Pipe to Elbow on base material of elbow

  • SAM 1-5 4-SJ-2150-14 Pipe to Valve SAM 1-6; 1-6A, 6-PR-1103-12 3/16 inch round indication 1/2 inch from fusion line on pipe side of weld Three linear indications, 4/23/92 4/30/92 4/22/91 5/12/92 B, and C Elbow to Flange one 3/4 inch, one 1/8 inch and one 3/16 inch

_on Flange side 1/2 inch from weld centerline. SAM 1-7 6-PR-1105-1 3/16-inch linear 4/22/92 4/22/92 Nozzle to Safe indication on nozzle side, End 1/4 inch from weld

  • centerline SAM 1-8 1 1/2-SJ-1132-40 1/4-inchlinear indication 4/23/92 4/29/92 Valve to Pipe on base material of valve SAM 1-9 6-SJ-1141-1 9-inch linear indication 4/29/92 5/2/92 Reducer to Elbow on weld SAM 1-10 34-MS-2131-lPL-19 1/4-inch linear indication 5/7/92 5/12/92 Pipe Lug on lug side
  • G-i I

I

  • APPENDIXG CUSTOMER NOTIFICATION FORMS Table of Contents (Cont'd)

CNF No. Area lndication(s) Opened Closed SJ\M 1-11, 34-MS-2121-2 1-inch linear indication at 5/13/92 5/19/92 11A, and 1lB Pipe to Valve fusion line on valve S~ 1-12 34-MS-2141-2 13/16-inch linear indication 5/16/92 5/19/92

  • Pipe to Valve outside Code-required examination area on valve body
  • G-ii

SOUTHWEST RESEARCH INSTITUTE CUSTOMER NOTIFICATION FORM CNF Serial No . ...9;'M / -/

                           /48/00 Examination Area: Z-.SJ- 113?- /"2-                    Procedure No. Ps.c .;VT-/
                                                                     -    I  ,~r.

Comments: PT Ex/7M/;V/.?Z?o/\/ g,cv/£./-7~/Z/2,, P T /!VO/C4 i7ov

               ?L?z 1' /ol'V6 4'? /.J 8&s/L....V7/,£/&c.. ~/-=- &.o/z W-/,1'/Ch' Attachments: 0474 SwAI Signature:

Comments:-----------------------------

                 /Pd 4.-<'4/V//N/?//C'r-/ #/--T1£~ ~.$'A..?/<"// c    w.-:ec.o    ,,,oe/;c'° Attachments:

Date: /.(,41?,e t/z.,,,

  • Customer Signature:

SwRI Form NOTR-CNF-1, Rev. 2 Date: t"-;8- 7..2-=

.~ SOUTHWEST RESEARCH INSTITUTE CUSTOMER NOTIFICATION FORM Project No. /7- 48 Z3 . CNF Serial No. r.5/? NJ/ - z.. Examination Area: -Z -S"J. - -Z/C,o - / C> Procedure No. PS/3-P T / Comments: P / '?"'?¢ dix'4M/U4C/O,<./ £/Cv/fCC?lj".O Z C,,,v/C.,;?<.

 /,A../.(.)/~/.7T/t0;C./S      v.../@(/~   £_LC/?   ca   7'?..//E 4/L4t/.//78L.'k.-

Comments: &,~~ 4/i.2 4:k?a!v/'r1d?E fA/Prt'ct!TdA.JS , Date:

SOUTHWEST RESEARCH INSTITUTE CUSTOMER NOTIFICATION FORM Project No. /'?- 48 Z 3 CNF Serial No. &1#11 -'3 Comments: ,,,vr /?,,.<4/V7/,,<.//?C/0.1./ A.'/ZV,g4c&:a I Ca;,o/~/7C.C6vV46'C'e C:/,,<.//Z'/7/Z /.;</.0/C'°/;7 Z?t>/'V' ( ~ " ) /A/ ,,.,;!Cc~/2.0/...7,A./[,,-Z V:.~ /!-/-I Z4o

  • Attachments: ,.Cldm //M89 SwAI Signature: Date: / ~ /?~/Z 9 Z-Date:
     .. .               : /,~*.: :.: .*:.*::;::*::::.::::;(:::::.*,:.'(;::.,:,=:p~~.:~. . : .~:=9~~~~~::~Y,:~!~i~li::.j1i!j:**.::.:,\:,i::':!.:**!1'.:*i111:!:1i::*.:*1:*:::.:*.1.!:1;,::.:*:.!:.ii*!*i1:::j.!ij:.!:i:*=.:::*:. :':. ,*:=* : *: :* *.* : *:,:.:.* ;,:*.,
  • Comments: f...a~ IA!dtcdiCAV Li A£ ~ a ~4¢'( u:= 1r/.f d L~l<r-bYDAtV<!.l?H;,.;. ~he- 74: ~ /HtZAV7iUl.£.A w/fl UT r""
   /k.tiuu t=Ar7A<, E4ff'A/AtC Is Ltm,?if.4 74°' &a A1M.1 ~ 11.. "12
  ,!lit ~(Ju<< ae ~AL 7:;;.~£#-otr-. WILL ~~aar H//s 11_~                                                                                                                            ~ -

Attachments: 1/0110

  • Customer Signature:

SwRI Form NDTR-CNF-1, Rev. 2 Date:

  • ~*1- #.J.

SOUTHWEST RESEARCH INSTITUTE CUSTOMER NOTIFICATION FORM Project No. / 3 Site: .'54~ / CNF Serial No. ~I- i 2- Cv- ~IL/7- /{ Procedure No. f!sE fJT I Comments: E4,1-#lr/l/A-T..r<YJ /(£1/EALS'D / L 11115~ ftl)"DI'(.'.+/ToN tu!f.reli E"XC..eEu s Tit§. &.t..?4J"'1.8<:.c p/1#~11.}s.:ra.t!s t?/° ~ $"3/s?3  ; SEc.~,u X I T?r~U :Z:w.13- ~nl/-~ Date: f- / r . 9>= Comments:-------------------=---------

      ;fiE:-XAMINA=(.]:Q>J         AFTr:.Q     ~~MEixc_ We.L.."1> ~~'? XE:V&K£b          Alo Attachments:    //t?-2f'S Customer Signature:                                                    Date:

SwRI Form NOTR-CNF-1, Rev. 2

SOUTHWEST RESEARCH INSTITUTE

  • Project No. 1£-if23 CUSTOMER NOTIFICATION FORM Site: SAU-/YI I CNF Serial No. ~I /-S-Comments: :Pr EX;1p1.r Jf/J4-T.XOA1 ,f}EV6Al..c) I r!ae~ /'fl-~ U)c.UA 3 <-c fit/J>.c-c4rr:aAI {% "') Jit/ /IC:t'eJ"'2LJ4A)c£ a;.pm 7?1&..: n&-3-::1'-l-.J.

oE ~£ 'Sfcfra,J -xL I o 3 /s3'3. ~..v.GSS/Ai"n_r-..v'.4-!.J - 533 Attachments: ])A-7?t //01/3 1

  • R£sow7r<::>AJ .3/a?07
  • Customer Signature:

SwRI Form NDTR-CNF-1, Rev. 2 Date:

.~ SOUTHWEST RESEARCH INSTITUTE CUSTOMER NOTIFICATION FORM Project No. 17- i(<l.J. ':3 Site: SAL.s/11 I CNF Serial No. StJ'11 I - ~ comments: fJr iSXA-11'1It1IA-:rI:8/J 3 LrAJGA'lf. :PJ~+".!:JA/s.

  ;a:: I    ~ ~Y *~ L1MJ'              w 11::ccJ1 s.K c.m s A:l.U> Wire ie LEAJl(,..~ :rru rtfaL£
CWB -3S7f/-~. £ .::> 4,.;-0 .3 A:~e. Ve" lhJb ~ ., RF;eif!:nl/&at Attachments:'I>blA II 01s//, Ri:sdLJdrdN 3 {000~
*Comments:   ALL ~    .

kNMrt

                                     .WA,..c421Qm 7i U El#& t2 tA ~tlf.1P+~A-lil.. te &/

I

&14 ~ /AIL)/cATa.vr. EhJhA/t; ?; M MOAH1i'£<4 1v/1( vr ~c41.rer A14H/dU')IM<ff &fib! 2"~ SHh41t:, ,fl'" Ht4 ~ t:J.~/s=~L or~ ~'ai{uer- ,fut<;vAL ~;'?'!&()I "dis I~ 4 ~,.,. sc/411,,41,
   ~                                                                                             .

Customer Signature:

                        -/IA~IJ                                 'Ef/Ekt.£0 ~ .,Frl/;)Z"c,,,~

Date: G. ,...., ('-* /('(]

SOUTHWEST RESEARCH INSTITUTE

  • Project No.

CUSTOMER NOTIFICATION FORM Site: Ste~ J CNF Serial No.~ 1-&.4 Comments: /'/ ,f{::5,K';fP{!r"1'A-7'I(:J/(/ / .L.Tll/t:,,-;e J"AJIJ.rc*~~Jf;1)

     ..,..~ E...(eet:-.ZJSniJt: ~4-8t.E .<FA-IC-r#-,                .t..r"N&,,-~ ~.Vvr--~.d..5 d, 3 itj
    /!eE 6J.z>t= ~i.o~.+..9Jce* .sE.E. CAJF S°;hf.1 1-'2
  • Comments:

w1r/ 71'L P4A Mt11t1t.. -ZZ-Iw&-3$7¥. .J(b} /9N Srf V&Lu&t.dfl,(: A14dc1J (urf fr<A ~"'4L'~

                                                                                           ~Wd.

Comments: EE *plf£t4:l Eb fJ I DJ;J rctrZ?r:? 1.1 :rs 4 !fEfhLht-tSte

  • Customer Signature:

SwRI Form NDTR-CNF-1, Rev. 2 Date:

-~ SOUTHWEST RESEARCH INSTITUTE CUSTOMER NOTIFICATION FORM Project No. Site: &LEM CNF Serial No. SAM I- 0 B b-/;(-//o3-/~ Procedure No. ~E -L,/7 ~\ Comments: l?X'14 M rAIA r;:QJJ ~ F ?r .IV~ICA ~o"1 ::t::E I t.Mz_,,, .Si1EI:T l I 019.:i."') AJ rTli 71fE tlr M lu#.1~ 71ZC!-) tYltttto2l Re VsAl...l.> =r t\E'.. r.<Jj).!£"'.A-TFQ.<l ro

  ,4 1fE,Poe]""l\BLt:_ L:r7JEA-1"' µJ3?rc"~A.) W HreH :rs ~E '4-L-Ll>t.0*~8LE, SEE. CAlF SA:M /-~

SwRI Signature: orJ...y~ou IZ ~~1>N ~ 4'/hr Date: ££"'"9..J. Comments: Rr:E,(A!YU'AIA r.rat..I tfE!'tR ELAt'.P.n.I~ ME14l£"D tlo tf@@ABlE {z. ~")

.rNrfrcJtm1.1s \tf1ol Pr I             vr t?tc171Z>.vs,      &:tr.14 /)rfJ{)J),c11-mv      s.rzc ..¥6"
  -r 8eFct<E             r,,Ji ~             0  ~                  ~ !     I  ~

Date:

SOUTHWEST RESEARCH INSTITUTE

  • Project No .
   . Examination Area:
                        /'7- L/<623 CUSTOMER NOTIFICATION FORM Site:

fv-f&-1/0 3 *-/ d.. 5Alfi& I Procedure No. CNF Serial No. ::5fWl 1-~C..

                                                                                          §   E - ?II :?I .t /'II Comments:             f2 E c= J(t+~11:: J/4 7ro ,'I)    "1-Ffc5. !="C,.,4;:p..rAlc;  Rev'c..+ c>=v   !lo
  • 1==eo£Vr't- El E Attachments: "l),p,-'4 / / e;;;i.3</r), ~yafu'.}(;;-)

SwRl.Signature:

    • Comments:

f/MzaY~ , Cc!Jd1/&!0£ fi.H,A/AJC uetfL Pr!Ad/cA77p&) lzH

                                  /)a  A11JT6+<<:#.8 , 600,             atJMu,~J#.nr Lf .~
                                                                                                            ,&4.LAJ l114&rl[;e                 ~Ate              w/d ur           7:1t~~s &/!tft'otl'<et.r:-e-ff Date: r?-'f.2-.

Co'Wlents: fJ r /EX~ A/lrf"Z4 A.f ~ "/?Jf1d ~ eE INDICA KEA/ ~el> No feUYf!..4 J1"18 IA!! ~;;~N. Attachments:

  • Customer Signature:

SwRI Form NDTR-CNF-1, Rev. 2 Date: _I

SOUTHWEST RESEARCH INSTITUTE CUSTOMER NOTIFICATION FORM 54~ I CNF Serial No. Stf?t? I- 7 Examination Area: 0-M -I/OS--/ Procedure No. ?s E -flr-1 /tJ/oI Comments: t2r ~)?4JJ1pVtf!;L!JN l?e.VBA-l.S.]) I eo:pc: A-u.awA~LE l..i::Ne.;tl( I@R;A~N {if?') :CAI ~~b~c.£ 1¢;1?1' '??kfC.G ;R,VE .av{,!- :2 I' P 5Pe:f:RJAJ XI ?'pl3 . Attachments: D/'fffl= J/t!Jll/O , Reow~IJ 31 tJal O SwRI Signature: Date: ,;;92 ~ 2 Z-I Comments:---------------------------- Attachments: Date:

SOUTHWEST RESEARCH INSTITUTE

  • Project No. I Z*

Examination Area: ff.2 ~ I~ CUSTOMER NOTIFICATION FORM Site:

                               - s:r-1/:l;:J.

MUM

                                                 -'-10 I             CNF Serial No. S.,f-JV/ 1-?

Procedure No. ?se-P"I\ Comments: Pr fEX14-MI NA-TX<JN Rc.-VV3ALE D / L.J:AI~

i:AJ"DrC?.J'\..~tJ uHf.~c.J~ b~ t..e~.s 77f!i &LL.aw A-BLC Drt11£1JSL<Jtl~
      ,of: rtk           A-SM E      13 *J.s 'i 3 s E.-~.:tt<J A) yr: 'JM3LE IWB 3 S-1t/- .:2 SwRI Signature:                                                        Date: .:<3 ~ 9 ~
  • .kii.~fl_fN!:~UL..~N'l....1;.7i°~~~~~~d~~ifd1!~-'-/Lr~*~~!-1.~~~r TM At~ uNff UT ~~A'< *Y:.. ~

Comments:--------------------------- AfEXMIN#rrarJ .4f'TG£ t'os.t~ WM ?t.:t' f'Etlt=AU'b Alo -~0#/ir Z°IJD~S* Attachments:

  • Customer Signature:

SwRI Form NDTR-CNF-1, Rev. 2 Date:

  ~                                            SOUTHWEST RESEARCH INSTITUTE
  • ~ CUSTOMER NOTIFICATION FORM Project No. I 7-- f/fZ .3 Site: 5.4:l.§nf I - CNF Serial No . .;AM 1- ct comments: fY-r 5',(4/1-'?fNA TroN
      /,A)/./-Cc .H  ;.:=::-)' <'..' £D.S       OJ:D        ££.aw~~G.. . Q..z:;;H~A./SI' d.V s .

Attachments: Utf72T //a.'~~ 8' f //t!J.;JY6 .1,Tfl~iilft~l-&il!l~--i*l?Y1i Comments: ;tN41c..,7/0N 7C AL B'At"~ 1b ~di.£ IF iLIS A- Aki<#. comments: f?; k7c/;XAtfrAhi~ N llE7CR &smFz:tC NetJ; ,/J;(?.e://Abt"T?-a1&t. REVE.Ale.]) No Vt9,r?R-04.Bl- XAll>Z:CA!:F<JM.S .

SOUTHWEST RESEARCH INSTITUTE CUSTOMER NOTIFICATION FORM Site: S4LEN1 CNF Serial No . .Yfn1 /-/0 Examination Area: 3 f-/JIS -,;// 31-1 P '- - J 9 Procedure No. fSE -J#r I comments: /11'/ ,(fM4f"PJ:Z2?,J ;?e(c!4l-G2> I &l>e #LuJW-4-Bl-E

            .::C:,1/LJ R"H TU> cJ . g ::     f't-Attachments:    J2tfT'4  / ::? Ct/$3 SwRI Signature:
  • Comments: _,_UL/l.:;.._,,j~--J.~~:..a::LLJ~--o11..::'S~..ps....A..,,i~.&LZ.~.&z--~.:?~~-=s~--L...;~l.---
         /k,m4          Yt*   19X':q .S93        Cl'.: ~4/ ~,4=/fut                              !1&;.;tt
  }; .

Comments:---------------------------- Attachments:

  • Customer Signature:

SwRI Form NDTR-CNF-1, Rev. 2 Date:

.~ SOUTHWEST RESEARCH INSTITUTE CUSTOMER NOTIFICATION FORM Project No. 17- ff'Z3 Site: :541.£#/ I CNF Serial No. S/kl1 1-1 I Examination Area: ~ '-/-/)/ 5 -.;2/~I - .;( . Procedure No. rs E - /\1 T I Comments: /¥r- £'YlbW.r11/A-z:r:;µAi E tiE.A-(.)Cl) ~Ne J:A/J:Jr0r-1X1:;4 w l.\.-R~ 6 XC.EF£'>S Cni:> E At+owl\Bl,,E. :hr;e.-tz.U~AJ.S. SwRI Signature: Customer Signature:

      ,_._ .,,.._.***-********* *.:: )(:~:./: . -.:.**..***
                                              )::::-=*::*-:***

Comments: ,RE f!)(j//l"l:f'A}JtTR) ,.J urce EM&/N~ RellpttVet.> r& :Ir.qt~AJ I ~<.. ' w~ eirU.O=> Ct;,pe 1 12> 3 E. i-=- Attachments: Date:

SOUTHWEST RESEARCH INSTITUTE CUSTOMER NOTIFICATION FORM Project No. Site: SA-~ I CNF Serial No. 5if111 1-)/14 Procedure No. ~.C - Mr I comments: forT S~AJ4i:r.o.V A~tc< ~N~.... R~et:;, I ,;; 0 0 sf TI ~e I YI~ w H::z:~ e.>'e...e.a s CD.be: ~w~<..,E .2>~s-t-0~.

> ee CNF .l...,.M /-I I Attachments:

SwAI Signature: Comments: .5WlZ fr~FCf!MGi) 7i1;! ~4>/JC hHlfwlR!h'/'DJIJ'4/~.tlhlf¥AIAT!2V'=.:C/) t/LSJ¢.F~ -

   .i=637s;        q '::: .yS""~} ~ f",et#s/6f-Si:Ji:. ,Pca;?S/(3) aesreFF,e-r j)~-C..,;'AIM~MJ~F Dtyql
   !Jf 6m'1.IL) ~--         se.e   11-mtc~ St'E1C:f4(.~t}, (ti) UsGo ~~~#II~~~                         TlJ  'lJ$k-~~

ZAIA!ZRTro(J Jf~lll;. 79 we,u,, iMllE, ~ - S6£ 4.rmel~ $'Ur:H Is) l'e~.t/:J /}J'r' ~ 5" ,,.,!JO~~ "1,U,])5 - - ~- .. z. :113J-2 Jc/I- I 'i!ff#*-2/a/-J 11/dr-.;1.1:11-z. ,11(,i Nl'

  • Customer Signature:

SwRI Form NDTR-CNF-1, Rev. 2 Date:

elDProject No. CUSTOMER NOTIFICATION FORM SOUTHWEST RESEARCH INSTITUTE Site:~ I CNF Serial No. $Ail( 1-//8 3 '/-/!/~ -,;; I~!- ;i. Procedure No. f?st: - /}f7 / Comments: AEIC.e /k,,e~L:N.r Alf &~l'f?tO""N.f'/I.atJhrseos~ lc12.ur.r~ By /Js~ f9" k112~c"'1J~ {sc4 (J.A/r SdJltl 1-114) &r fl!)D~.,,_rr4JJ clCf.IJS t'Llo e #fcl4wA eu; 1JJ;+111"1S.Id u ::.*, L .= /. d' 7 r, tt ::. * '/~. I Attachments: SwAI Signature: Date:  :(It 7/9.;2 Date:

P~Rl'*~.1. ;.
1l:!'~~~~n.P¥::~!~~!f:.i::. :l:!::*:i*l!:i,l:.. *:.:i*;1!i.::\*jl.:i*i)!:.;:!1 *:)..:il!.!ili:/:ii!i!:i.::::*i;i.:.;;:.**:;...:.. :**.:*****. .*.*. :.*. :***.*.*.***

1

                        .......... *.* ****:*******.*:*y****:::.::.*..                                                                 =*i*::l:j..
  • ~--..._.;._---------------~~~~~

Comments: AS Pett p15P4S1T/QN ro 9::Ju,a 9017 (iJJ(=dsMo-9Z*S¥') I. w= 1'Rrt4 FU!.. ll*llTIAL T?1Jl.c:.(AJ<<SS 2 l!.em<11Je INl2tCA7Zm.I BY '1e#lfNrC,,H_ dll?t/"6

  .A)oT m at:a:P . ~oo '7"#dusm.,.. . .J llflT Tt> 12§~ oPerr 1Zmo11A1e .. " PERFcrzm Fi""AL 'TlfJq<dgs:, tYlElfStJtt.l(h2.!7$ ANa f"o(?'4/Af2(:J lq!"$()LrS 712 etVCr.

Date: ~- -/ 1- 'l t... Comments: ee'i. ~~A-r'"".-crJ /If -r Rev~ t.Jo e~te.0<'t'~t-e :c~~..J. Attachments: D1f+ b..4JVJ Date:

SOUTHWEST RESEARCH INSTITUTE

  • Project No. I 7--'/~ 3 CUSTOMER NOTIFICATION FORM Site: SA-lEtq I 1-12 Comments: Ml SXAM.rt\JA-~tJ Rec.D£DE..b oAJ D~Tl"t-6=-&Jeb IP?otJ/3 Re~ tfA1 .:i:AJD&cArI<JoJ r#?l-r .r...s o~-rsxDe 77/£ Cci>t:

k'e'Ri.,JJAe.ef) G.t~.:r:-n/11-i:a::JAJ t?=A16). 'L#E fNJ>.kA--rIO,./ ,J;S ,k}Uf'~b tJH :r~ .-19-~ VA-Lv'c 73oJ:>'1 (14-Jf'IS-/(.7). .:nrJ~N SwAI Signature: Customer Signature: Comments: rc"c/1'1'N.J:C#<,. £~v..ft'... le~ '7Mr ~ .:r.t11vr4r-rz:.eJ.v ~ .&,rrs6 . Attachments: !Jdi! l!,e~,ui

  • Customer Signature:

SwRI_ Fenn NDTR-CNF-1, Rev. Date:

  • DISPOSITION TO 921009017 SEAT 92-322 14MS167 LINEAR INDICATION IN AREA OP PIPE TO VALVE WELD THIS DISPOSITION WILL ADDRESS THE REPAIR OF 14MS167 VALVE.

THE VALVES ARE PART OF THE PSEG PIPE SPEC. 1Sl2A, WHICH IS SAFETY RELATED, SEISMIC I NUCLEAR II AND QA REQUIRED. THE MAINT. REQUIRED TO REMOVE THIS INDICATION DOES NOT REQUIRE A CODE JOB PACKAGE.

1. LOCATE AND CLEARLY DEFINE THE AREA TO BE WORKED.
2. UT AREA FOR INITIAL WALL THICKNESS
 *3    USE MECHANICAL MEANS TO REMOVE INDICATION. DO NOT REMOVE MORE THAN 0.400 WITH OUT SYSTEM ENG APPROVAL.

4 NOE AS REQUIRED TO INSURE THAT THE INDICATION HAS BEEN REMOVED. 5 BY USING MECHANICAL MEANS CONTOUR THE AREA TO A 3/1 SLOPE. 6 FINAL NOE REQUIRED AFTER ALL MECHANICAL WORK HAS BEEN COMPLETED TO INSURE THAT THE INDICATION HAS BEEN REMOVED AND THE SURROUNDING AREA IS FREE OF DEFECTS

  • 7 FORWARD AS FOUND AND FINAL WALL THICKNESS TO SYSTEM ENG FOR DISPOSITION OF THE DR.

TESTING

1. PERFORM A MT OR PT EXAMS AFTER THE REMOVAL OF INDICATION IN ACCORDANCE WITH ANSI B31.7.
2. PERFORM A UT FOR AS FOUND AND AS LEFT WALL THICKNESS IN THE AREA OF TKE INDICATION. ACCORDANCE WITH ANSI B31.7.

Index of NI8-2 and NR-1 Forms I. NI8-2 Forms Component Brief Description 1AF128 Replaced spring washer, spring and nozzle 11M815 Machined nozzle 118J39 Replaced disk insert and spindle assembly 18J67 Replaced nozzle, disk and bellows II. NR-1 Forms Code Job # Brief Description P90-034 Replace spools 1099XA and lOOX-A to accommodate new transmitters P90-036 Addition of vent valves to RHR system P90-039 Add new pipe supports to RHR system P90-212 Replaced studs on valve 18J5 P90-313 Replaced 11SJ48 valve and bolting in kind P90-316 Replaced 12C810 valve,* Mark # FA-17 with Mark # FA-131 P90-338 Installed new bonnet, studs and nuts in valve 11CS36 P90-339 Installed new bonnet, studs and nuts in valve 12CS36 P91-067 Replaced 11 and 12 FCU penetration piping with piping of new design and material P91-068 Replaced 11 and 12 FCU penetration piping hangers and supports to accommodate new design P91-071 Replaced 13, 14 and 15 FCU penetration piping with piping of new design and material P91-072 Replaced 13, 14 and 15 FCU penetration piping hangers and supports to accommodate new design P92-010 Replaced valve*11GB3 with new design and modified associated supports P92-0ll Replaced valve 12GB3 with new design P92-012 Replaced valve 13GB3 with new design and modified associated supports P92-013 Replaced valve 14GB3 with new design 891-074 Replaced snubber 1C-CVC-SN901, 8/N 321 with 8/N 26130 891-075 Replaced snubber 18-14FW-8N013B, S/N 476 with 8/N 30359 891-076 Replaced snubber 18-13FW-8N015B, S/N 389 with S/N 26131 891-084 Replaced spool piece elbow 1M8-4037B in kind 591-111 Replaced bonnet studs and nuts on valve 1CV284 891-122 Repaired pitting on # 11 Steam Generator secondary handhole by machining 591-167 Performed weld repair to pipe spool RD-1-SW-259 591-238 Replaced bolting in flow orifice 1Sl2A 891-256 Replaced bolting on valve 1CV7

  • 591-265 Replaced # 11 Boric Acid Transfer Pump mechanical seal 891-280 Replaced # 12 Boric Acid Transfer Pump mechanical seal

~------------------------------------------ S91-287 Weld repaired 15SW58 valve body and replaced flange bolting S91-306 Replaced cage, plug and stem assembly on valve lPSl S92-097 Performed weld repair on 15SW72 valve body S92-155 Replaced (8) bonnet studs and nuts and (16) flange nuts and (8) studs on valve 1DR29 S92-168 Performed weld repair of airlock personnel hatch hinge S92-179 Replaced bolting on valve 1CV171 S92-188 Replaced snubber # lA-SI-SNlOOA, S/N 450 with S/N 25872 S92-190 Replaced snubber # 1S14-FWSN-15B, S/N 488 with S/N . 27911 S92-191 Replaced snubber # 1Sll-FWSN-12B, S/N 440 with S/N 25893 S92-192 Replaced snubber # 1S-11FW-SN012A, S/N 389 with S/N 25856 S92-193 Replaced snubber# 1C-PR-SN007, S/N 623 with S/N 17676 S92-200 Repla_ced -stem and p~ug assembly on valve 12MS171 S92-202 Performed weld repair on 12SW72 valve body S92-203 Performed weld repair on 12SW58 valve body and replaced valve bolting S92-215 Replaced disk in valve 1CV52 S92-216

  • Replaced plug and stem assembly in valve 13GB4 S92-218 Replaced plug and seat in kind in valve 11GB4 S92-226 Replaced flanges and bolting in orifice 13MS200 S92-227 Replaced bolting, plug and stem assembly in valve 14MS169. Hanger removed and reinstalled to facilitate maintenance S92-228 Performed weld repair to valve 13SW58 S92-229 Performed weld repair on valve 13SW72 S92-232 Replaced plug and stem assembly on valve 1PS3 S92-235 Rewelded valve canopy after maintenance on valve 11SJ144 S92-236 Rewelded valve canopy after maintenance on valve 14SJ17 S92-241 Replaced bolting on valve 1SJ3 S92-246 Rewelded valve canopy after inspection on valve 14SJ139 S92-247 Replaced valve canopy by welding on valve 12SJ144 S92-254 Replaced bolting on valve 11SJ34 S92-256 Replaced bolting on valve 1CV7 S92-264 Replaced helicoil in bolthole # 1 of # 11 Steam Generator S92-269 Replaced bolting in valve 11SJ55 S92-270 Replaced primary manway bolting on # 14 Steam Generator hot leg S92-272 Replaced bolting and seal plate on valve 13SJ56 S92-280 Replace~ valve 14SJ144 with valve S/N CD-569 S92-285 Replaced pipe clamp on support # lC-PRH-179 due to corrosion S92-291 Replaced stem assembly and bolting on valve 1PR6 S92-296 Performed weld repair on hanger lC-CVCS-587 which was removed to facilitate maintenance S92-297 Replaced plug and stem assembly on valve 1CV75
  • S92-300 Replaced rear bracket by welding on snubber lC-PRSN-007

S92-301 Performed weld repair on seat and body and replaced

  • S92-302 S92-303 S92-304 bolting on valve 11BF22 Performed weld repair on seat and body and replaced bolting on valve 12BF22 Performed weld repair to body and seat on valve 13BF22 Performed weld repair on seat and body and replaced bolting on valve 14BF22 S92-309 Replaced plug and stem assembly on valve 1CV3 S92-312 Replaced mechanical seal on 1SJE3 Safety Injection Pump S92-313 Welded in new seat, replaced disk, valve bolting and flange bolting on valve 1FP148 S92-316 Performed weld repair to pipe support and replaced pipe guide on support lC-CVCG-232 S92-317 Performed weld repair on flange face of 1SJE3 - # 12 Safety Injection Pump S92-318 Replaced heat exchanger bolting with upgraded material on 1RHE3 heat exchanger S92-325 Replaced bonnet and bolting on valve 1PS28 S92-329 Replaced cage assembly and performed weld repair on plug of valve 1PR2 S92-333 Performed weld repair to pipe spool between 1CS6 and 11CS44 valves S92-335 Repaired welds on elbow spool lCVC-15 that was removed to facilitate maintenance S92-339 Weld 7/8" fillet weld in lieu of existing threads on yoke-bonnet for valve 14SJ54 S92-340 Replaced stem and wedge and enlarge wedge guides by machining on valve 1PR6 S92-344 Machined rupture disk seating surface on lRCEll -

Pressurizer Relief Tank S92-350 Replaced bolting on valve 12SW58 S92-352 Performed weld repair to reactor instrument tubing - 6522XD S92-360 Replaced plug, stem assembly and bonnet on valve 22GB4 S92-362 Replaced plug and stem assembly and rewelded leak-off bore which was cut out to facilitate maintenance on valve 1CV55 III. Vendor NR-1 Forms Work Order Brief Description 920627062 Repair # 11 Steam Generator nozzle and replace piping 920627064 Repair # 12 Steam Generator nozzle and replace piping 920627066 Repair # 13 Steam Generator nozzle and replace piping 920627067 Repair # 14. Steam Generator nozzle and replace piping

  • I
  • FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
1. Owner Public Service Electric & Gas Co. Date __9_-_2_3_-_9_2_ _ _ _ _ _ _ _ _ _ __

Name Foot of Buttonwood Rd.,Hancocks Bridge,NJ Sheet _ _l_ _ of ___ l _ _ _ _ _ _ _ _ __ Address

2. Plant Salem Nuclear Generating Station Unit ___l _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

Name Foot of Buttonwood Rd.,Hancocks Bridge,NJ Pl-406255 Address Repair Organization P.p. No., Job No., etc.

3. Work Performed by Crane-Aloyco, Inc. Type Code Symbol Stamp.....::N.:.;;R;.o.__ _ _......:.VR.::..:.._ _ __

Name Authorization No. ____6.. . .;. 3_ _ _ _ _2_6_2 _ _ __ 104 N. Chicago St., Joliet, IL 60431 ExpirationDate Feb. 17, 1994 July 2, 1993 Address

4. Identification of System_--=S=-a=f-=ec..:t:..Y.__=I.:..:n:...j<....:e:...c:..t==i..::o..:.n=---------------.,---------------
5. (al Applicable Construction Code ASME VIII 19_&LEdition, N/A Addenda, _ _.:..:Ne<./..::A;:,____ Code Casa (bl Applicable Edition of Section XI Utilized for Repairs or Replacements 19 83 S83 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components
  • Name of Component Name of Manufacturer Manufacturer Serial No.

National Board No. Other Identification Year Built Repaired, Replaced, or Replacement or Nol ASME Code Stamped (Yes 11SJ39 Crosby 51341-3 N/A N/A 1987 Repaired No

7. Description of Work_---=R"'"'e"'p=l-=a"'c""e""'d=---=d'-=i:.:s::..:k=---1=*=n'-=s"'e=-=r=-t=--.=a:::;n::..:d=-c..:s=p.=i:::;n:..:d=l=-e=--.;:;;a:..:s:...:s=-e=-m=b-=l::...YL.:.*- - - - - - - - - - - - -
8. Tests Conducted: Hydrostatic ~ Pneumatic 0 Nominal Operating Pressure D Other D Pressure 1 737 psi TestTemp. Ambient °F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided 111 size is 8% in. x 11 in., (21 informa-tion in items 1 through 6 on this report is included on each sheet, and (31 each sheet is numbered and the number of sheets is recorded at the top of this form. *
  • (12/821 This Form (E00030I may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017

FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this R:e~aia conforms to the rules of the ASME Code, Section XI. reparr r rep ace~ent Certificate of Authorization No. --~6-3------'2~6,:,2,_____ Expiration Date -::.i2c,/<-l....:..i7'->/'-'9~4--.;:,7'"'i,_'2~/"'9+3+----- Signed,,/ ../.Le.4: ~- Owner or Owner's Deslgnee, Title Date i t!1I - I. , 19 9 2... CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New Jersey and employed by ArlEwriljfit: Mut:ual Iftsuraftee Ce. of _ _,,,~------------------------------have inspected the components described in.this Owner's Report during the period Jttne 1990 to April 1992 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this.certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual System ___ (,T_~_,l" "-_.'(k!>J~!l.~,n.sp=------------ National Board, State, Province, and Endorsements Dat.._e_ ____./_*l?----<- f..___ _ _ ,/f Z----*

FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Public Service Electric & Gas Co - Date _ __,,9:...-~2,,..3""---9~2 _ _ _ _ _ _ _ _ _ _ __

Name Foot of Buttonwood Rd. , Hancocks Bridge, NJ Sheet-~"'--- of_ _.....__ _ _ _ _ _ _ _ __ Address

2. Plant Salem Nuclear Generating Station Unit _ _.......__ _ _ _ _ _ _ _ _ _ _ _ _ _ ~

Name .. Foot of Buttonwood Rd ** Hancocks Bridge.NJ Pl-406255 Address Repair Organization P.O. No., Job No., etc.

3. Work Performed by Crane-Al o¥co, Inc - Type Code Symbol Stamp__.NJLR.,,__ _ ___,.VR:..n..._ _ __

Name Authorization No. _ _ _ _6.........,3.___ _ _~2""6 2_ __ l04 N. Chicago St., Joliet. IL 60431 Expiration Date Feb 1 7, 1 994 .In 1 y 2 . 1 993 Address

4. Identification of System __S=a=f:...:e:;..;t::.Y..__..::I;.::;n:..J'-e::.c::....::t..::i:...:o:..:n=-----------------------------
5. (al Applicable Construction Code ASM'E VIII 19--6.5.,_Edition, N/A Addenda, _ _N~/~Z\....__ _ Code Casa (bl Applicable Edition of Section XI Utilized for Repairs or Replacements 19 83 S83 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components
  • Name of Component Name of Manufacturer Manufacturer Serial No.

National Board No. Other Identification Year Built Repaired, Replaced, or Replacement or Nol ASME Code Stamped (Yes 1SJ167 Crosby 51341-M3 N/A N/A 1988 Repaired No

7. Description of Work Replaced nozzle, disk and bellows.
8. Tests Conducted: Hydrostatic ~ Pneumatic 0 Nominal Operating Pressure 0 Other 0 Pressure 1750 psi TestTemp. Ambient °F NOTE: Supplemental sheets in. form of lists, sketches, or drawings may be used, provided (11 size is 8% in. x 11 in., (21 informa-tion in items 1 through 6 on this report is included on each sheet, and (31 each sheet is numbered and the number of sheets is recorded at the top of this form .
  • (12/821 This Form (E000301 may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017
  • FORM NIS-2 (Back)

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Repair conforms to the rules of the repair or replacement ASME Code, Section XI. Certificate of Authorization No. ______,6. ._. 3_ _ _ _ _~2.._6......,.2_ _ _ _ Expiration Date _ ....2.,./_l._..7_,./_9"-'4"'--_ _,7~/c..2<.+/-9,__3...__ _ __

  • Signed /.L.-/.,. .L ;-1. '

Owner or Owner's Deslgnee, Title CERTIFICATE OF INSERVICE INSPECTION Date I() - 4 I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State

                                                                                                                                                       , 19    ? ?-....

or Province of New Jersey and employed by Arkwright Mntna l Insurance Ca of _ .........,._______________________________ have inspected the components described in this Owner's Report during the period _ ___,.u.l,,.nu.n.uei=.......1'-'9=9"-0,_______ to--A'-'p_..r._.;....1.___.1...9"'9.,..2_ _ _ _ _,, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this.certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any.personal injury or property damage* or a loss of any kind arising from or connected with this inspection. Factory Mutual System

 -______::::+.~B£__--==£..!.._,....::....::C:....::._~--=---commissions_A/~.:J.~J~'/_J                        _ _ _ __

National Board, State, Province, end _Endorsements Date_ _ _ _ _19 f V _,,_J_l)_..,._f'

  • FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 . Owner Public Service Electric & Gas Co. Date _ _9_-_2_3_-_9_2_ _ _ _ _ _ _ _ _ _ __

Name Foot of Buttonwood Rd.,Hancocks Bridge,NJ Sheet _ _l_ _ of ___l _ _ _ _ _ _ _ _ __ Address

2. Plant Salem Nuclear Generating Station Unit ___l_ _ _ _ _ _ _ _ _ _ _ _ _ _ __

Name Foot of Buttonwood Rd.,Hancocks Bridge,NJ Pl-406255 Address Repair Organization P.O. No., Job No., etc.

3. Work Performed by Crane-Aloyco, Inc. Type Code Symbol Stamp--=N.:.::Rc::..__ _ ___:_V..:.R.:..__ __

Name Authorization No. -----'99*-c1J----~26'Ge..62--- 104 N. Chicago St., Joliet, IL 60431 Expiration Date Feb. 1 7, 1994 July 2, 1993 Address

4. Identification of System ___M_a_i_n_S_t_e_a_m_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

Draft ..Pump & Va~ ve

5. (al Applicable Construction Code ASME ..21Z 19~Edition, N/A Addenda, _ _-il:f_*Sf:...._:W_._ _ _ Code Case (b) Applicable Edition of Section XI Utilizecfifo{~~iafr';tn:ieplacements 19_8_3_8_83 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components
  • Name of Component Name of Manufacturer Manufacturer Serial No.

National Board No. Other Identification Year Built Repaired, Replaced, or Replacement or Nol ASME Code Stamped (Yes 11MS15 Crosby N55100-03 N/A N/A 1989 Repaired Y~s 0045

7. Description of Work. _ _--'M...,,,a,.,,c....h...,1"n=e'-"d,__,n'"-'o=z-=z"'l..,e==-----------------------------
8. Tests Conducted: Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 0 Other~ Pressure 1074 psi Test Temp. °F Steam NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form .
 * (12/82)                   This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017

FORM NIS-2 (Back) Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Repa j r conforms to the rules of the repair or replacement ASME Code, Section XI. Certificate of Authorization No. _ ___,,6,,_3.,______2.....,6...2 - - - - Expiration Date -2'1-/_.1_71-.,,,_1.;;i9"'4~--i7'7/c...2'f-/_.9,,..3;>----- Signed1_L"""--~"""'{L~""',£,'"""'.....,'"'*"'~""*

                                               =-'--------------Date Owner or Owner's Oeslgnea,*Tltle
                                                                                                       / 6     ~             G
  • 19 9  ;?,_.

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of New .Jersey andemployedby Arkwright Mutual Insurance Co of _ _.,...,,_______________________________ have inspected the components described in this Owner's Report during the period, _ __,..._J... 1..,9..,9,..Q,,______ to._--...A*p"'r...:i....* ...1~1.,.9,......9,_..2,,______ , and state that u...n..e~... to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this*certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual System

 ----=lQ~~~./~~;-'"""~""--"-"'----Commissions------'--"-M~~-=-J-=-=1J
            ~actor's                         Signature National Board, State, Province, and Endorsements Date,_       _,/'-'c.9o<....-'_.t'._*_ _ _ _19        f },/
  • FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
1. Owner Public Service Electric & Gas Co. Date_-"""9_-_.,2,_..3,_-_,9"""'2.,___ _ _ _ _ _ _ _ _ __

Name Foot of Buttonwood 'Rd. ,Hancocks Bridqe,NJ Sheet_~,,,___of _ _" " - - - - - - - - - - - Addreu Unit _ __...__ _ _ _ _ _ _ _ _ _ _ _ _ _ __

2. Plant Salem Nuclear Generating Station Name Foot of Buttonwood Rd ** Hancocks Bridge.NJ Pl-406255 Address Repair Organization P.O. No., Job No., etc.
3. Work Performed by Crane-Aloyco. Inc. Type Code Symbol Stamp__.NJLIR~-----"VB""'-----

Name Authorization No. _ _ __..6c..3L-----2""""6~2~-- 104 N. Chicaqo St., Joliet, IL 60431 Expiration Date Feb 17, 1994 July 2. 1993 Address

4. Identification of System _ __..A.,.u...,x..,1...
                                                 * ... 1_..a...r_,y!--F.._..e...e...a...w..,a.._t.,...e,,.r_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

1 ....

5. (a) Applicable Construction Code ASME VI I I 19-65,_ Edition, N/A Addenda, _ __.,N.,./"'A,._____ Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 83 S83 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components
  • Name of Component Name of Manufacturer Manufacturer Serial No.

National Board No. Other Identification Year Built Repaired, Replaced, ASME Code Stamped (Yes or Replacement or No) 1AF128 Crosby N56711- N/A N/A 1974 Repaired No

7. Description of Work*--R~e""p~lr..aa-c.....:e... a.._.s..,p'"'*r..i.i""n....g~lw.'1e1a.:.s>.1-h1.1;e~r"'-r,___,:;S>f.p.1.ir... nw,ig'-=<a;LJn.1.1du.....un1.1.n""z~z~l-1::e,______________

2.1.."

8. Tests Conducted: Hydrostatic D Pneumatic [3 Nominal ~perating Pres~ure n Other D Pressure 75 psi Test Temp. AmbientoF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1 I size is 8% in. x 11 in., (2) informa-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form .
  • (12/82) This Form (E00030) may be obtained from the Order Dept., ASME, 345 E. 4,7th St., New York, N.Y. 10017
  • FORM NIS-2 (Back)

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Repair conforms to the rules of the repair or replacement ASME Code, Section XI. Certificate of Authorization No. ----=6"'3,_______,2"-'6=2____ Expiration Date __.2..,._/...,l_,7'""'/'""9""'""'4'----'-7.,./~2._,,f-/~9'-3..___ _ __

  • Signed......:/L...4'.&_"""o::.a.c-<..,~4°""",,.

or Province of New Jersey

                                               .."""..4...._-' - - - - - - - - - - - - - - - D a t e _ , _ _ / _ , *b=-------=~;_ _ _ _ _ _ _ , 19 f Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State and employed by Arkwright f-1utual Insurance Ca Z

of __MA _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ have inspected the components described in this Owner's Report during the period _ _J_u=n~e~=l~9~9~0~-----to April l 99 2 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.* By signing this.certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual System

               ~lnspec~tor*s*
               ~                                            SCrb1"gnature.

Commissions ___ N__,J __J_*_?_3-------------- National Board, State, Province, and Endorsements Date_ _ _,/_IJ_,..-=-f____19 c; V"

FORM NR-1 REPORT OF REPAIR = MODIFICATION'.: OR INSTALLATION OF REPLACEMENT($)~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

    • workperlormedby _ _P_u_b_l_i_c_S_e_r_v_i_'c_e Foot of Buttonwood Road, Bancocks Bridge, NJ 08038

__ E_l_e_c~t~r~i~c'--&_G_a-'--s---=-C~o~m~p~a~n~y'----N_u-=--=.c~l~e~a~r---=-D~e~p~t~.=---C~J=-=-P__:i--=P~--9~0_-_0_3_4_ 1adoress1 1reoa1r organ1zat1on*s P.0 no .. 1ob no .. e1c.1

2. owner ___P_u_b_l~i_'c_S~e_r_v_i~c~e'--E_l_e_c_t_r_i_c-'-&--=G~a~s:.......cC~o~m~pao.....:....n_.._y_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _~

(name) Foot of Buttonwood Road, Bancocks Bridge, NJ 08038 (address I

3. Name. adoress and identification of nuclear power plant Salem Nuclear Genera ting Station Unit t 1 Foot of Buttonwood Road, Bancocks Bridge, NJ 08038
4. ldentificatlOn of system Reactor Coolant Nuclear Class I I
5. a: Identification of component repaired, modified or replaced Spools 1099XA and lOOX-A Replaced b: Name of manufacturer PSE&G c: ldentilymg nos. _ _ _N_/_A

_ _ _ _ _ _ _ _N_/_A_ _ _ _ _ _N_/_A_ _ _ _ _ _ _N_/_A_~- _ _ _1_9_7_6_ __ (mlr."s serial no.) (Nan Bd. no.) ijurisdicl1ona1 no.I __ --.cother) (year built)

6. Applicable section(s) ___ X_I_ _ of ASME Code, 19~ edition 1983 addenda Summer Code Case N/A
7. Design res::::>onsibilities __ P_S_E_&_G---------------------=--..,-------------
8. Tests conco.Jcted: hydrostatic ~ pneumatic = design pressure = pressure 128 psi.
9. Descriptioi- of work Replaced pressurizer relief tank level transmitter spools to cuse ot aod1t1ona1 sheet(Sl or ske1ch1es1 1s acceptable 1t propeny identified) accomodate new transmitters.
            ~                           Work Order #900727124                                 DCP lE0-1003 Package 1
10. Rema.~s=-----------------------------------------------

Original Construction Code No Code Cases ANSI B31. 7 1969

  • ~~~~~~~~~-Construction Code ANSI B31.7 1969 Code Cases N/A Manufacturer PSE&G Code Symbol Stamp N/A System Inservice Test perf orrned at NOP CERTIACATE OF COMPLIANCE We certify tha: ~!ie statements made in this report are correct and that all design, material and workmanship on this _ _R_e_p~l_a_c_e_m_e_n_t__

(rapaJI. iT'Dddca11on or *~I) conforms to tr:..; applicable section of the ASME Code. Certificate of ~horization no. 36 PSE&G Nuclear Department S~ned _ _ _-:-....,..---:-.--:---- (repair 0 . alien) to use the "NR" October 3 19 9_1_ __ Manager-Station QA (!ill) lk(diili)

                                                                                                                                                                                           ,19'i/

CERTIFJCATE OF INSPECTION I, the undersig."led holding a valid commission issued bv The National Board of Boiler and Pressure Ve5$elhlns~ors, and certificate of com-

                                               .                   New Jersey                                                        ArkViig 1t Mutual Ins. Co.

petency issue:: by the state or province of Norwood, MA and employed by _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

 --=--~--~~------of                                                                     have inspected the repair, modification or replacement desaibed in this report on      1-J.-1       19CJ     J       and state that to the best of my knowledge and belief, this repair, mod!ic:atbn or replacement has been made or constructed in accordance with Section XI of the ASME Code and the National Board rules as defined il the publication NB 102 current edition.

By signing this certificate, neitherthe inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modfication or replace mart described in this report. Furthermore, neither the inspector nor his employer shall be iable in any manner for any personal ihjury or property damage or loss of any ki rising from r conn ed with this inspection. Factory Mutual System Date z.*/8 199_l_signed {. Authorized inspec:IOI) Commissions---,.N~~ ......J.._7&...3,.___ _ _ _ _ _ _ __ Nlf1 Bd. ID. ('n::MlnQ anOcnemlllllll) llae OI p!CMnc:e and ~ This form may be obtained from The National Board of Boiler.and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 NB-81 Rev. s

FORM NR*1 REPORT OF REPAIR = MODIFICATION i: OR INSTALLATION OF REPLACEMENT(S) TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

                                                                                                                                                                         =
1. Work performed by Public Service Electric & Gas Company - Nuclear Dept. CJP t P-90-038 tn*me1 Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 lad~d~re~ss-,--------------------~

Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 1add*ess1

3. Name. address and 1dentif1cation of nuclear power plant Salem Nuclear Generating Station Unit f 1 _

Foot of Buttonwood Road, Bancocks Bridge, NJ 08038

4. Identification of system Residual Heat Removal Nuclear Class I I
5. a: Identification of component repaired. modified or replacec_S_e_e~C=-o_n_t_i:-'n_u_a=-t=-1=-*o.::..n:.:__.::..S.:..:h...::.e-=e-=t~------------

b: .Name of manufacturer See Continuation Sheet c: Identifying nos. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ See Continuation _S_h_e_e_t_ _ _ _ _ - - - - - - - - 1m1r s serial no.I (Nan Bd. no,) ourisdoctoonal no.I *- -4alller) (year builll

6. Applicable section(s)_ _X_I_ _ of ASME Code, 19~ edition 1983 addenda Swmner Code Case*--------

N/A

7. Design responsibilities _ P _ S _ E _ & _ G - - - - - - - - - - - - - - - - - - - - - = - - - - - - - - - - - - - - -
8. Tests conducted: hydrostatic ~
9. Description of work pneumatic = design pressure Addi t i on of vent valves to RHR system.
                                                                                                     =        pressure       585          psi.

1use of add1t1ona1 sheeus1 or sketch1es1 *S acceptable 1f prooeriy' identified!

10. R*m*~s: _ _ _ _ _ _ W_o_r_k_O_r_d_e_r_#_8_9_1_0_2_3_1_2_1_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

Work Order 4900709139 DCP t lSC-2259 CERTIFICATE OF COMPLIANCE October 3 19 9_1_--,-_ Manager-Station QA CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission issued bv The National Board of Boiler and PressurekVeS$81 ln.soectors, and~rtificate of com-NeW" Jersey Ar wrigntrMutua~-Ins. co. petency issued by the state or province of Norwood, MA and employed b y - - - - - - - - - - - - - - - -

 --..,.------=~------ of                                                          have inspected the repair, modification or replacement described in this report on ,,?  1- f'        19 , q/      and state that to the best of my knowledge and belief, this repair, modificatk>n or replacement has been made or constructed in accordance with Sectk>n XI of the ASME Code and the Natk>nal Board rules as defined in the publication NB 102 current edition.

signing this certiftcate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modiftcation placement described in this report. Furthermore, neither the inspector nor his employer shall be &able in any manner for any personal injury property damage or loss of any ki 'sing from or ed wit~ this inspection. Factory Mutual System Date 7 ... LY 19!11_ s9ned C.Ommissions-..,.,/J~cr,__J__,7.,;...:;~~-------- Na11 Bel. no. ~~la) 11111 P"Mnce and runt>er) 0t This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., C.Olumbus, OH 43229

            .                                                 ..                                                                                                            NB-31 Rev  !

FORM NR-1 REPORT OF REPAIR = MODIFICATION = OR INSTALLATION OF REPLACEMENT(S) ~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

  • Work perfc~ed by Public Service Electric & Gas Company - Nuclear Dept. CJP # P-90-039 1name1 1reoa1r organ1za11on*s po no .. 100 no. etc 1 Fou~ o~ Buttonwood Road, Hancocks Bridge, NJ 08038 1ad:::d:-'-re-ss-,----------------------
2. 0 wner _ _ _ Public Service Electric & Gas Company

_ _ _ _ _ _ _ _ _ _ _ _...:_-=-==-~==-~:.:..L-----------------------~ Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 1address1

3. Name. address and identification of nuclear power plant Salem Nuclear-Generating Station t;Jni t t 1*

Foot of Buttonwood Road, Hancocks Bridge, NJ 08038

4. ldent1ficat1on of system Residual Heat Removal
5. a: ldent1f1cation of component repaired. modified or replaced __ C_-_S_l_-_P_-_R_H_G_-_2_7_2_,_2_7_3_ _ _ _ _ _ _ _ _ _ _ _ _ __

b: Name o' manufacturer PSE&G c: ldentify1"lg nos. N/A N/A N/A N/A 1991 1mfr s senal no.J (Nan Bd. no.1 (Jurisd1c11ona1 no.1 !Other) (year built}

6. Applicable section(s) ___X_I_ _ of ASME Code, 19~ edition _ _l_9_8_3_ addenda Summer Code Case _ _N_/_A __
7. Design res:>onsibilities __ P_S_E_&_G____________________________________
8. Tests conc"cted: hydrostatic = pneumatic = design pressure _ pressure N/A psi.
9. Descript 10 ~ of work Add new pipe supports to RHR system.

tuse ot add1t1ona1 sneet1s1 or sketch1es1 is acceo1ao1e *' croo-e~*y 1dent1f1edl io. Rema~s: _ _ _ _ _ _W_o_r_k __ O_r~d_e_r---,,-#~8~9~1~0~2~3~1~2~1_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ Work Order #900709139 DCP USC-2259 CERTIACATEOFCOMPUANCE 4 We certify tha: :~e statements made in this report are correct and that all design, material and workmanship on this Replacement con Iorms tot:-.; appI.1cabl e section

  • of t he ASME Cod e. (repair. rrod1lcal10n OI raplacemen1)

Certificate of

                  ~1ho1ization.no.
                 "PSE&G Nuclear Department 36 to use the "NR" s a                                 October           3       19 Manager-Station QA 91 7                                   CJ
                                                                                                                                                                                                                      /

Signed . ,19 _ __ (repair o izalionJ (aU!horized represemai (li!lel CERTIACATE OF INSPECTION I, the undersigned holding a valid commission issuM by The National Board of Boiler and Pressure Vessel lns~ctors, and certificate of com-

             .                                 .                 New Jersey                                                           Arkwright Mutual Ins co petency 1Ssuec by the state or province of                 Norwood:, MA                             and employed by                                                                               *          *
  --~-~--~~------of                                                                     have inspected the repair, modification or replacement described in this report on      J-/ f         19 'i /        and state that to the best of my knowledge and belief, this repair, modification or replacement has been made or constructed in accordance with Section XI of the ASME Code and the National Board rules as defiled in the publication NB 102 current edition .

By signing this certtticate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modttication

  • or replacemeri: described in this report. Furthermore, neither the inspector nor his employer shall be fiabla in any manner for any personal ihjury or pro~ 9arnage or loss of any kin ising from ~npectedwith this inspection. Factory Mutual System Date *1-/f' 19q/ Signed
  • 4,.,,.t_.

Authorized inspedor) Commissions #.JJ?:J

                                                                                                                         --:-:Na"l-:-:Bd.::---no-.-(ncludi"---ng-erdor.;--eman-ts-J-111.a!-e-01-p-rtM-.r<:e-and_nu_llber)

This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229

                                                                                      .                                                                                                                              NB-81 Rev   5

FORM hf'-* REPORT OF REPAIR _ MODIFICATION :.... OR INST ALL.A 1IUN ur M~l"'L.A\..t:.Mc.n 'l~i TO NUCLEAR COMPONENTS ANO SYSTEMS IN NUCLEAR POWER PLANTS Public Service Electric ' Gas Company - Nuclear Dept. C.JP t S-90-L.:2 Foo<:  ::= Buttonwood Road, Hancocks Bridge, s.;i 08038

                                                                                                   *.00-.H-.----------------------~
                          ?nblic Service Electric '                              Gas Company Foo~      c:=  Buttonwood Road, Hancocks Bridge,                                            s..::r      08038 3 Name a:i:~e$5 and 1dent1!1cat1on of nuc1ear power plant                                  Salem Jluclear Generating Station                                                      Unit   t l F~ :.! Buttonwood Road, Bancocks Bridge, lLJ 08038                                                                         _

4 1den!1*1cr*or- :-* systerTI Safety In iection Nuclear Class I I 5 a IOe"t** cro"' ot comoonent repaired. modified or reptaced_l_S'-J_5_V_a_l_v_e_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ o Name::* -.a,,ufacturer Anchor Darling c 1cent,...,*!"~ nos _ _ _ _ _F_A_-_4_6_ N/A N/A !i/A 19EE

                                      ,mh !t set*a* no
  • i...1rrso1c11ona1 no ;

6 App11cat>e se.=11on1s1 _ _ _ _X_I ot ASME Code. i9~ edi!ion _ _l~9_8_3__ adde11da Summer Code Case_ _S"~/A _ __

      ~ Des.gn ~=~s11:>1l1t1es ____                P_S_E_&_G_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

8 Tests cO"'c-e*eo. !iydrcs:at1c _ pneumatic : design pres~ x pressure NOP psi.System Inservi::e ~est

      ~ Desc**p~ar :-* .... or1<                  Replaced studs in kind from folio.

11.** se o* aCJO*l*Or.a !t!"oH'! ! :r* ~-.e1crues; 1c~e::~1c11e .~ :rooe**- oent1li.01 1 o RemirU: ------~,--W_o_r_k_O_rder # 9006012 2 5 CERTIACATE OF COMPLIANCE CERllACATE OF INSPECTION

1. the u~ed holding a valid commission issu~e>' Ther~ff'al Seard of Boaer and Press~:~~Jr£~iia~m~~f com-petency ~s-.ec by the state or province of Norwood, MA and employed b ¥ - - - - - - - - - - - - - - - - -
of  !-.ave ir.~ed the repair, modificalCln or replacement desc:i:ec r: :l"lis report
  • ' on Y-16 199/ and state that to the best of my knowledge and belief, this repair, modfcation or replacement has~ made or construcled :rr accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB 102 comnt editiln.

By signin; this certificate, neither the inspector nor his employer makes amy warranty, expressed or mplied, concerning the repar_ ~tticatDn or replacement described in this report. Furthermore, neither ~e inspector nor. his employer shall be iable in any manner for any piitS:mal i'ljury

  ! or prope-ty cmmage or loss of any ki                  ising from or n                 ed wih this inspedion.                                   Factory Mutual Sys ten                             /

II Date 7-/~/ 19 f / Signed *

  • Commissions N;J}7'3
  • Aulhon:llld insoeaCJll ~a1 Bel. 1111. :inca.an; ..-clenemenSJ swu =r ~ ..., ..,"'Dir!

This bm 'may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Coll.lfrbLS.. OH 43229

                                                                                                                                                                                                          "<8-3*

A.-. ~

FORM NR-i REPORT OF REPAIR.::. MODIFICATION= OR INSTALLATION OF REPLACE.MENT(S) :'.: TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

  • Work perton-eo= b~ Public Service Electric ' Gas Company - Nuclear Dept. C..,"? t S-90-313
  • Poot c! ~uttonwood Road, Bancocks Bridge,*:; 08038 iadore1s*
                 *Foot of Buttonwood Road, Bancocks Bridge, NJ 08038
       ~Name. adcres.s and identification of nuclear power plan'.                     Salem Nuclear Generating Station ~t t 1 Poot~of Buttonwood Road, Bancocks Bridge, NJ 08038
       << ldent1f1cat10,. :;'system            Safety Injection N'.iclear Class II
       " a ldent1f1ca* on of component repaired. modified or rep.aced __l_l_S_J_4_8_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
b. Name of -~~ufacturer _C_r_o_s_b~y_V_a_l_v_e _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _~

c ldentifyin; "IOS. 1N600378 N/A N/A N/A 1970

                                                                   !Nat BC "'IC I                                                              10111811                                     CJ** built)
Applicable ~*on1s1 ___X_I_ _ of ASME Code.19~ edition 1983 addenda Summer C::ce ~--N-'/_A_ _
       -    Oe~gn resp~~s1bilit1es __P_S_E_&_G--------------------~--------------~

_ Tests condu::-:~c hydrostatic * = pneumatic =  ::es1gn pressure = pressure NOP psi. Syste:r. :nservice Test

Description:

  • .,.. 0 rk Replaced valve and bolting in kind.

Work Order #8909C7C32

     *c     R *m*"'s=--------------------------------------------

This valve replace~..ent S/N NE-9971-01 was ordered to ccec: requirements ANS! Bl6.5 1968.

                                                                                                                                                                                  ,;~nlacemer:t CERTIACATE OF COMPLIANCE
      #Ve certify that~ statements made in this report are ccrrec: and that all design, material and workmanship or. this
                                                                                                                                                                               .......,. -=o:i'i:ioon a *ec..aarw-*.

I

     =:.onforms to the :;,;>pltcable section of the ASME Code.

Certificate of A.--.orization no. PSE&G Nuclear Department 36 to use the *N

  • October 3 19 91 Manager--~5~£-at~1-on QA '-

Ii*,£ I SiQned~~----,-...,,....,,.---~

                            ~         . *ianl
                                                                                                                                                                      -___,....      t?otk-'-1~; 19 ..YL__

cmi CERTIACATE OF INSPECTION

t. the under~~r.ed holding a valid commission issue§~ \S~~~k~al Board of Boiler and Pressu~r'kV!!\j-i~~ <frt~Bf. com-
>etency issued ':::If the state or province of Norwooa, MA and employed b ' f - - - - - - - - - - - - - - - - -
  • of have inspeded the repair, modification or replacemirt cescrbed in this repon
 .I  :tin 'J -Z IO          19 Iq          and state that to the best d rrrt knowledge and belief, this repair, modricafon or replaclil'l":el't has been made                                                     °'

nstructed in accordance with Section XI of the ASME COOe and the National Board rules as defll"led in the pub&catCr. NIB 102 CtJrrent ealti:>n. signing this certificate, neither the inspector nor his emplOyer makes any warranty, expressed or implied, cor.cemin; h repair.* modlication replacement described in this report. Furthermore, neither tt\e inspedor nor his employer shall be iable in any man~er 1or ariy personal injury

  • .::ir proi:;:rty da1!"39e or loss of any k F ising
                                                            -from?'

i ~ed :"ith this inspection. _J.actory Mutra1 System / Date (Q_-Z~ 19q) Signed~ -~~ ~Id.~ Commissions NJ 31}

                                                                                                               --::Na-.,,1:-::90.:-::--ro-.-:~...,...,:-f'lll-.-d::l-:--'5-e<rsai--ll:a.-1:6-;wMa--.,,.--and-/U-ITt---.,-

This form m~ be obtained from The National Board d Boiler and Pressure Vessel lnspedors, 1055 Crupper AV£.. Collmbus, OH 43229 NM1

                                                                                                                                                                                                               "-" 5

FORM NR-1 REPORT OF REPAIR C MODIFICATION O OR INSTALLATION OF REPLACEMENT(S) E TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

    • Wof1( per1ormed by
2. Owner
                               .Public Service Electric & Gas Company - Jluclear :::ept.

Foot of Buttonwood Road, Bancocks Bridge, NJ 08038 Public Service Electric & Gas Company lr.amBI (address) (name I CJP t s-90-316 orgaruz.alion*a P.O. no .* 1ob no .. etc.) Foot of Buttonwood Road, Bancocks Bridge, NJ 08038

3. Name, adCJ:ess and identification of nuclear power plant Salem Nuclear Generatin9 Station Unit t 1 Foot of Buttonwood Road, Bancocks Bridge, NJ 08038
4. ldentificahon of systerr Containment Spray Nuclear Class II
5. a: Identification of component repaired, modified or replaced _ _ l_2_C_S_l_O_V_a_l_v_e___________________

b: Name of manufacturer Rockwell International c: *Identifying nos. N/A N/A 'S/A N/A 1970

                                 .imtr.'s serial no.)             (Nat'I. Bd. 'no.)               ourisdlCllO!'lll "c. ..                                                     (Year built)
6. Applicable section(s1.___ X_I_ _ of ASME Code, 19~ edition _ _ l 9_8_3__ addenda Summer Code Case_ _N_/_A_ _
7. Design res:::>onsibilit1es _P_S_E_&_G_____________________________________
8. Tests concucted: l!ydr:::static ~ pneumatic C: design pressure p~ssure 263 psi.
9. DescriptiO"ofworj( Replaced valve mark iFA-17 with new ...-alve ma='~ tFA-131 S/N 1664.

(use of additional shee11s1 or s~etcl'll~  ! .ic:::eptabte ii ~ .aen11fled)

10. Rema~s: _ _ _ _ _ _ w_o_r_k_O_r_d_e_r_l_B_9_0_9_1_8_1_6_6_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

DCP tlS0-00086 Pkg. il CERTIFICATE OF COMPLIANCE CERTIFICATE OF INSPECTION I, the unders.;~ned, holdi,,i;;; a valid commission issued by The National Board of Boiler and PressurE Vessel Inspectors, and certificate of com-petency iss~d by the s:~e or province of New Jersey and em~oy9d by Arba:'i.ght Mutual Ins* Co*

 --~------------of Norwood ,MA have inspected the repair.-, modificatim or replacement described in this repon 3 . . z._ , '!11..._and state that to the best of my kn£_w~ge and belief, this repair, modHcation or replacement has been made or ccordance with Section XI and Sectiot1 m-~10.6"1E &de aid t:-1e National loard rules as defined in the publications
 -NEMi!~'ld-<l'ilS-1   , current editions. By signing this certificate, neither the Inspector nor his empltyer makes any warranty, expressed or im-plied, concerning the repair, modification or replacement described in this report. Fwrthermore. raithet' the Inspector nor his employer shall Date     tf.... J     1lfl
                                                         / /                        .              CommiSSiions._ _
Jct:ory be liable in any manner 11or any personal injury or property. damage or a loss of an11* kind arisin' from or connected with this inspettion.

Signed_"Z * ~

                                                                        ~

J_J_73 Mutual System (Authorized lnspect0f1 (Nat'I. ac. a llncluding endorsements) state or province and~ This form may be oblai&ed from The N11lonal Board of Boller and Pressur9 Vessel Inspectors., 1055 Crupper Ave., Columbus, OH 43229

                                                                                                                                                                                               *N~

Rew.*

FORM NR*1 REPORT OF REPAIR~ MODIFICATION TO NUCLEAR COMPONENTS ANO SYSTEMS IN NUCLEAR POWER P..ANTS

                                                                                                                         =       OR INSTALLATION OF Ftf?UCEMENT(S)::;

Work perf =*~d by _ _P_u_b_l~i=--c-=S""""e~rv__..i_c_e--"':!""l'"-'e;....;c'"""'t::...:r'"""i""c'--*=--Ga~s'-:":"::-C::-o_m.... pa-=n...y_---:.N:...::u:..:c:...::l:..:e:..:a:::::~Oe:..::::.11P:..:t:..:.:.............::c.:r=.:P:..__f!....-~s~--=9~c!_-_,3:!..:3~8=---

                                                                                                                        ',..me'                                                      * - ~-
  • Po ftC. /CIO l'IC... .n:.1 Poot of Buttonwood Road, Bancoclts Bridge, NJ U8038-
800'9Sa:

2 O ~ner --=-==-===___.;:::-==~'-"-':.._;==-~.=...::...::=.-=.---===---=:.::..::~~==~-'-----------------------

    . -               Public Service Electric
  • Gas Comn_any Poot of Buttonwood Road, Bancocks Bridge, NJ 08038
3. Name. adc--ess and identification of nuclear po*e* :>!ant Salem Nuclear Generati1?9' Sta':ioc Oni t f 1 Poot of Buttonwood Road, Bancocks Bridge, NJ 08038
  ** ldentilicat~ of system Containment*-5pray Nuclear Class I I
s. a: ldent1f1e4111on of component repaired. modifiec o~ replaced_-=1-=l~C-=S-=3~6'---'V~a=l=--v:...:e=------------------
b. Name o* manufacturer _.:..:A=l_,,,o:.L-;:;:c:..::o'-----------------------------------

c* ldentifyi"lg nos. N/A N/A N/A N/b 1987 (mtr:s serial no.I !Ms Bd. no.1 ourildicl1ona1 no.) 10"*1

6. Applicable section(s) XI of ASME Coc:e. 19~ edition 1983 addenda Sunmier *Code Case N/A 7 Design res=*onsibilities --=Pc.::S:.:E:..:&:.;G=--C=-o~.- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
8. Tests co,.,=..icted: tiydrostat1c = pneuma1*: = design pressure :- pressure NOf psi. 1:.s:ial Leak Examinatio:

9 Descriptic- of work Installed new bc::u:et, studs and nuts *

                                                                                  .. M  01   iidCJ1t10~.1    5~ff~    s or sk.etcr.tes1 rs acceptable .t D'OOtr'"'                        -~~.!'90
10. Rem1Bs: _ _~W=o=r=k---=O~r-=d=e=r~#~8:...:9~0~8~1=-5=-2=-5=-C"----------------------~--------

CERTIACATE OF COMPLIANCE i We certify tl":a: ~'":e statements made in this report a*e ::erred and Iha: a" design. material and worlc-ansi'\ip er tt:is _,,__,!,-~=-~~i_r___11P_iacei--.,.-.-, conforms to ~-~ applicable section of the ASME Cod6. 1 7 1 l October 3 19 9_1_ __ Certificate of A...sthorization no. 3 6 S~ned ___P_s_E~&_G-,-N_u_c~l-.e_a~r____ Manaqer-S~tion QA

                                                                                                                                                                                                                              !WI 6ftr *19~/
                        ~        *Ian I, the unde~'"led holding a valid commission issuad bv The National Board of Boiler and Press1ml \'lassel ln~rsLand ~e of com*

patency cs~ by the state or province of

                                                                           ~ev Jersey                                                                                   ArJcvr1qlit Mu ~uCll rns. -co.

and employed by _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ NorwOOd , MA .

 ------..,---~-----of                                                                                 have inspected the repair, modificatial OI" repla:atr.iant descri:led in 1his report on    1- f' J           19  q/      and state that to the best d my knowledge and beriet, this repair,                                                               modrcamn                    01 qpla:ement has been made or constructed r. accordance with Section XI cl the ASME Code and Iha Nafunal Board rules as defried ii the pltllcat1Dn NB 102 anent edition.

By siJning this certficate, neither the inspector nor !'Ms employer makes Mr/ warranty, expressed or irr;fied, c:orcemiing the rePair. modification or replacernet"i described in this report. Furthermore, oeither the inspedor nor his employer shaD be icOie in il'1 manner for ant~ Injury or~ damage or loss of any ki * *ng froi;i..or ~eded with this inspection. Factory Mrtual Syatea Date /, "'/~ 19 Cf! Signed 7, ~ Commisslons---;;~Al.~'f°~J~7.-!'J=-===-------,~-,--~-

                                                                       ~~                                                                                       Nll19d.rm..~~)U.Ol~&'ldl'All!tlel)

This form rr.zr be obtained from The National Board of Boiler and Pressure Vessel lnspedors, 1055 Cruppir Avie., CokJfl"bus, OH 43229 NB-31 l'I... !

FORM NR*1 REPORT OF REPAIR_ MC.~.FtCATION .: :._ OR INSTALLATION OF REPLJ. :.:..~ENT(S)}; TO NUCLEAR COMPONEN:S A.ND SYSTEMS IN NUCLEAR POWER PLAPI.-~

  • Work perl orme<:1 o Pub 1 i c Service E: ~ ~ :- i c ' _G_a_s_C_om__._p_a_n_,y,___-_N_u_c_l_e_a_r_D_e_:p::....t_.__-_""_t_s_-_9_C_-_::_::_?__

Foot of :uttonwood Road, Banco:::oe:.s Bridge, ,;; 08038

 *                                                                                                  .~*ess
      ~   Owner --~P~u~b~l~i~c,_,S~e~r~v~i=c=e-=E~l~e~c=-t~r~i~*c.::_='-~=::>a=-=s----'C~o~m~p~a_n_y...__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _~
                                                                                                      .... l">e Foot of Buttonwood Road, Banco:::ics Bridge,                                                    N:     08038 3 Name. address and 1dent1f1cat1on of nuclear po,,.e* :*a~*                                Salem 'iuclear Generating Sta tio::                                                  :Jni t t 1 Foot of Buttonwooa Road, Bancce:its Bridge-, N: 08038 _

Containment Spra: ~uclear Class II

  • ldent1f1cat10I" o* system _ _ _ _ _ _ _ _ _ _ _ _ _ _- - - : - - - - - - - - - - - - - - - - - - - - - - - - -

5 a. ldent1f1cat1on of component repaired. moc:lif1ec :r *ec*.aced __1_2_c_s_::_c_V_a_l_vc..:e=---------------------

b. Name of manufacturer __A-,l_o-'y=-c_o_ _ _ _ _ _ _ _ _ _ _ _ _ _ _- - , - - - - - - - - - - - - - - - - - - - -

c ldent1fy1ng nos S70WDD Kr. N/A N/A 19E:-

                                                                        *1'<* k 'IOI 6 Applicable sect*on(s), ___         x_r__ of ASME Coat. *s~* editior.                                         1983                addenda        Summer                  :.:ice Case _ _N_.:~;_.__

PSE&G 7 Design respons1b1t1ties - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 Tests conauc~ed hydrostatic = pneumatic : :les1gn p*ess .. *~ = pressure NOP psP.ysten =~service :-: ::-:: 9 Description o* ,,.ork _ _ _ Replaced _____ _ _ _==~~~s bonnet ____ and __ n~ts ___ in _kind._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

                                                                           ..:?e :* B:J~*11orii11 s:-:~* ~      :* s-e1..:n1es1 *s aic:eo1ao1e 1t :iroperi.,. 10el"'.~.**e-:
     -o     Remirks: _ _ _ _ _ _w_o_r_k_o_r_d_e_r_#_B_9_8_~--*_2_:_3_2_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

ta;TIACATE OF COMPLIANCE ca:mACATE OF INSPECTION I, the undersigned holding a valid commission iss1.;~~ T~~~~al Beare of Boiler and Pressu~r~~t!'J'h~~.}arf ~~c:a'-eat. :::::r-petency issued by the state or province of Nono~ , MA and employed by _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

      ----~---------- of                                                                     have inspec:ed the repair, modification or replacerrart :lesaibed in tr~ ~

J on 'J -If 19q / and state that to the bes1 ':Irr., knowledge and belief, this repair, modWication or repla:amient has been rra:ie er constructed in acx:ordance with Section XI of the ASME Code and the NatOral Board rules as defined in the plblicalcr. !1118 102 cumm ecft:O-_ 1 y signing this certWicate, neither the inspector nor his r.ipoyer makes any warranty, expressed or implied, c:or<:emris '.r.'le repair, mo:!Tca:Dr. replacement described in this report. Furthermore, reit."':er the inspector nor his employer shall be fiable in arrr m~.er1or any perSO'".aJ r,iJJY or pro~rty d~e or loss of any ki ising from or ::or't"l.Jdasl with this inspection. Factory .Mut-..al. System Date~ -Z- 1911 Signed

                                                                    ~ ~

c;: ~ Commissions--:/l/-:--~-=-=-J-?-=-3--:--::----------- Nai1 Bd. no.~~ s:a1 at J)nlWin:a arc -.uTlllW' This form may be obtained from The National Boart cl Boiler and Pressu-e Vessel Inspectors, 1055 Cruppe.' Ave.. ~lumbus, OH 43229 16-r

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION~ OR INSTALLATION OF REPLACEMENT($) 0

                          .              TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of/fP
1. Work performed by pnbl j c Send re El ect:ri c & r-as Co. - Nuclear Dept. CJP #P91-067 Rev. 8 (name) (repair organization's P .0. no., job. no.,etc.)
  • Foot of Buttcxn.rxrl Boad 3 H.mcxx:ks Bridqe, NJ 08038 (address)
2. Owner Public Setyjce Electric am Gas Co.

(name) Foot of aittonwood. Road* Han::ocks Bridge, NJ 08038

                                                                                                   * (address)
3. Name, address and identification of nuclear power plant '-=-'sta==t=i:.=a.::..:n=---...::Uni=':..:t::........l#l!...:1=--------
                                                                              --=Salc=so=em=-.....Nu=c=l=e=a=r:........;:Genera===-=tioo='

F<x>t of Buttonwocrl Rred, Harqx:kg Bridge, NJ 08038

4. System Send oe Water Nuclear Class II
5. a: Component repaired, modified or replaced #11, 12 Conta irnrent Fan Coil Unit, Penetration Pip.irn &

b: Name of manufacturer ---Con.-.~lD?""""X~-------------------------"'SlJPP0~4"!!>..,.rts~...______ c: Identifying nos. See Attachmen....t ...s~----- WA 1991 (mfr's. serial no.) {Narl.Bd.No.) Ourisdictional no.) {other) {year built) d: Construction Code ANSI B11 7 1969 1970 N/A II ANSI B31.l 1967 FAtgitionJ {addenda) {Code Case{s)) (Code Class)

6. Section XI 1983 sumrrer 83 N/A

{edition) (addenda) (Code Case{s))

7. Applicable edition. of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 N_/_A_ __

{edition) {addenda) ~e Case(s))

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *1969 1970 Attached
                                                         *ANSI B31. 7/ANSI B31.1 1967 Ed./                                                      (edition)           {addenda)             {Code Case(s))
9. Design responsibilities PSE&G PS 'EfW* Spec. S=C-MBQO-M00-043 & SGS/M-FD-1
10. Tests conducted: hydrostatic Da pneumatic O design pressure O** pressure B;;J. 2 psi Code Case(s)_..:N""/..:A~------
11. Description of work Repl ared send ce water penetration pipi..rg with pipi.rg of new design (use of additional sheet(s) or sketch( es) is acceptable if properly identified)
        ,_~a~nd  . . . . .~maug,Jt~e~r~1~*a.1.L.6..----------------------------------------

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms. to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no.

  • 36 to use the "NA" stamp expires Oct. 3, , 19 94 92-. _ _ Co.

PSE&G -Nuclear Dept. ~ ~ ~ Principal Engr Date '9- 9 19, Signed._ _ __ ____ _ _ _ ,4<£Ac-.&;,e.&,.* {repair organization) {authorized representative) (title) CERTIFICATE OF INSPECTION

   .1. the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of             New Jersey             and employed by                    .Arkwright Mutual                      Insurance Co of        MA              have inspected the repair, modification or replacement described in this report on                           3-ilf           , 19 f"V       and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National
   . Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement desaibed in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
          .                                              .(7 __                   / A _                                                      Jacto:ry Mutual System
              '1- f/           , 19 CJ Z, . Signed ~.n,/                   f      ~                                 Commissions         A,IJ    17]                                                !

{Inspector) {Nad.Bd.No.{induding endorsements)slale or province and number) This form may be obtained from The National Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB-81 Aev.6

Page 2 of/O CJP # P91-067 Rev. 8

  • Construction Code, Code Cases N-453-1, N-454 and N-455 Test No. Component Pressure Temp.
 #1          #11 CFCU Supply & Return        305 PSI       80.4°F
             #12 CFCU Return
 #3          #12 CFCU Supply                 310 PSI

CODE JOB PAC. COVBR CORTilfUTATIOH SHEET PL¥ 5c'('> 1~ CJP HO.: P-91-067 DATE:JAlfUARY 11, 1992 PAGE 2A OP

                                                                                                             *7 RBVISIOH:~~-=O~~~

UHIT~:~-=S=AL==BK=--=1~~~

  1. 11 PCU RETURH WORKING COPY CJP
  • H-453-1, H-454, H-455 W.O. H0.:910913101
                                                        ***EHG. SPEC.: S-C-MBOO-JIDS-043         SGS '11-PD-1 DBS. CODE &*YR.

AMO CODE CASE FAB. CODE & YR. AND CODE CASE* INST *. CODE & YR. CODE AND CODE CASE SYMBOL/ MANUFACTURER/ OLD COMPONENT ASME SERIAL NO. NB NO. YEAR "NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI PULLMAN KELLOGG 1-SW-289 II 831.1 1967 831.7 1969 B31.7 1969 1973

  • II 1-SW-P-6486 II II II II II
                                                                           "                            CONNEX 1991 PULLMAN KELLOGG II RD-1-SW-289A        II       II      II
                                               "        II      II 1973 1-sw-P...:.6486
  • II II CONNEX 1991 II II PULLMAN KELLOGG II II II II II II 1973 RD-1-SW-289A "

1-SW-P-6487 II II II

  • II II II II CONN EX 1991
***                                  II                         II UE&C 1974 lP-SWA-PS-54        II       II
                                                "        "                 II
***                                  II
  • lP-SWA-PS-54 II II
                                                "        "      "          "                            PSE&G 1992 PULLMAN KELLOGG II       II     II         II l-SW-290B           "        "       II 1973 II       II
  • II CONNEX 1991 1-SW-P-6488 " " " II PULLMAN KELLOGG II II RD-1-SW-290 " "

ijl

                                                                           "                            1976
  • II II CONNEX 1991 1-SW-P-6488 II
                             "       "                           91        II PULLMAN KELLOGG II     II RD-1-SW-290          II      II       II
                                                "                          II 1976 II 1-SW-P-6489          "       "                  "        "      II
                                                                           "                            CONN EX 1991
         - ~-

CODE JOB P . , COVER COllTillUTATIOll SRllB'l' foo,e 4 oF- (O

  • CJP NO.: P-91-067 DATB:JANUARY 11, 1992 PAGB 2B OP 7 UNIT: SALEK 1
  1. 11 l'CU RBTURlf WORKING COPY CJP RBVISION:~~~O~~~

W.Oe N0.:910913101 DES. CODE & *YR. FAB. CODE & YR. INST. CODE & YR. CODE AND CODB CASE AND CODE CASE AND CODE CASE SYMBOL/ MANUFACTURER/ OLD COMPONENT ASME SERIAL NO. NB NO. YEAR "NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI PULLMAN KELLOGG 1-SW-290A II BJl.1 1967 BJl.7 1969 lBJl.7 1969 1976 II II

                          "        ..        II      II     II       II DELETED 1992
  • CODB JOB ~AGB COVBJI COllTIIRITATIOll SHEET f<<qt> S "'y;: 'o
  • CJP MO.: P-91-067 DATB:JA}fUARY 11, 1992 PAGB 2C O* 7 RBVISIOM:~~-0......_~~

UNIT: SALP 1 WORKIN*G COPY CJP ..;c W.O. M0.:910913101

#12 PCU SUPPLY                                                              ./

DBS. CODE & YR. FAB. CODE & YR. INST. CODE & YR. CODE ARD CODE CASE AND CODE CASE* AND CODE CASE SYMBOL/ MANUFACTURER/

  • OLD COMPONENT ASME SERIAL NO. NB NO. YEAR NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI MASONEILAN 12SW58(AA-105) II DRAFT l?&V 1968 DRAFT P&V 1968 831.7 1969 N-00113-37-2 N-857 1975 II II II II II
                                                 "              II       II
                                                                                      "         "     RELOCATED 1992 ANSI             ANSI             ANSI                                    PULLMAN KELLOGG RD-1-SW-239-2          "    B31.1      1967  831.7       1969 B31.7    1969                           1976
     . "               "        "       "        "        "     "        "                            DELETED 1992 PULLMAN KELLOGG 1-SW-239C              "        II
                                        "         "       "     "        "                            1973
       "               "        "       "         "       "     II
                                                                         "                            DELETED 1992 PULLMAN KELLOGG 1-SW-239A              "        II      II        II      II     H       II 1973
       "               "        "       "         "       "      "       "                            DELETED 1992 PULLMAN KELLOGG 1-SW-2398              "        "       "         "       "      "       "                             1973 II
                       "        "       II
                                                  "       "      ID
                                                                         "                            DELETED 1992 PULLMAN KELLOGG 1-SW-240               "        "       "         "       "      "       "                            1973
  • CONNEX 1991 1-SW-P-6519 " " " " " " " PULLMAN KELLOGG 1-SW-240 " II II
                                                  "       "      "       "                             1973
  • CONN EX 1991 1-SW-P-6520 " " " " " II
                                                   ~B
      **                                CODB JOB             COVBR, COll'UllllTATJ:Oll SBBBT f"l<je b "" ro CJP HO.: P-91-067 DATB:JANUARY 11, 1992 PAGB        2D OP     7 RBVISIOH:~~-=-0~~~
 #12 PCO SUPPLY WORKING COPY CJP
  • 11-453-1, 11-454, H-455 ***BHG. SPBC.: S-C-KBOO-MDS-043 W.O. H0.:910913101 SGS/K-PD-1 DES. CODE & YR.

MD CODB CASE FAB. CODE & YR. AND CODE CASE* INST. CODE & YR. CODE AND CODE CASE SYMBOL/

                                                                                               '       MANUFACTURER/

OLD COMPONENT ASME SERIAL NO. NB NO. YEAR "NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI PULLMAN KELLOGG , 1-SW-2408 II 831.1 1967 831.7 1969 831.7 1969 1973 1-SW-P-6520 II . ti

  • ti
                                                    "         "       ti CONNEX 1991 PULLMAN KELLOGG RD-1-SW-240A     ti
                          "       ti        ti
                                                    "         ti      II 1973
  • CONN EX 1991 l-SW-.P-6521 " "

ti ti lP-SWA-PS-50 ti ti II II II UE&C 1974

 ***                              ti
  • ti II PSE&G 1992 lP-SWA-PS-50 "

ti

                                                    "                 "                               PULLMAN KELLOGG RD-l-SW-240A     "       "       ti
                                            "       "         "       "                               1973
  • H l-SW-P-6522 " " " " " ti CONNEX 1991 PULLMAN KELLOGG It u 9t 1973 1-SW-241 II ti
                                  "                                   ti u               u
  • u II CONN EX 1991 1-SW-P-6522 ti
                                                    "                 ti
                                                  ~B COVBR COllTillUTATIOll SBBB'l' jh.</)llc7'~to *
  • CODB JOB CJP BQ.: P-91-067 DATE:JABUARY 11, 1992 PAGE 2B OP 7 RBVISIOB:~~.._..;:;.O~~~
  1. 12 PCU RBTUIUJ WORKING COPY CJP
  • 11-453-1, B-454, B-455 ***BBG. SPEC.: S-C-llBOO-llDS-043 W.O. B0.:910913101 SGS/K-l'D-1 DES. CODE & YR.

AND CODE CASE FAB. CODE & YR. AND CODE CASE* INST *. CODE & YR. CODE AND CODE CASE SYMBOL/ MANUFACTURER/ OLD COMPONENT "ASME SERIAL NO. NB NO. YEAR NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI PULLMAN KELLOGG 1-SW-258 II 831.1 1967 831.7 1969 831.7 1969 1973 1-SW-P-6511 II II II

  • II II II II CONN EX 1991 lP-SWA-PS-55 II II II II II II II UE&C 1974
      • II II II
  • lP-SWA-PS-55 " " " " PSE&G 1992 PULLMAN KELLOGG II II 1973 RD-1-SW-259 " " " " "

1-SW-P-6512 II II

  • II II
                                 "                 "                    "                           CONNEX 1991 PULLMAN KELLOGG II      II                II        II         II 1-SW-2608         "                         "                                                        1973 II      II
  • II II 1-SW-P-6514 II
                                                   "                    "                           CONNEX 1991 PULLMAN KELLOGG II      II      II        II      II        II         II RD-l-SW-260                                                                                          1979 1-SW-P-6514       II      II       II
  • II II II II CONNEX 1991 PULLMAN KELLOGG II II II II RD-1-SW-260 II II
                                                             "                                      1979 II
  • II II II l-SW-P-6515 II
                         "                 "                                                        CONN EX 1991 MASONE I LAN 12SW72(AA-105)    "  DRAFT P&V   1968 DRAFT P&V    1968       II         II    N-00113-39-2 N-857    1974 II
                 "       II
                                  "        II      II.       .          "          II         II RELOCATED 1992
                                                                                                                                         ~
           *-                                      CODB JOB P A . " COVBR
  • COJl'l'IlllD'l'ATXOH SHBB'l' DATB:

PAGB P<qe ton) CJP HO.: P-!1-~v1 4 *I 2

  • C/'2 21 OP 1 won:<!NG COPY CJP RBVIBIOH:

W.O. H0.:910913101 f UlfI'l' i SALBll 1

 #11 AHO #12 PCU SUPPLY 6 RBTUIUI DES. CODB "- YR.       FAS. CODE (r YR.                   INST. CODE & YR. CODE AllD COOS CASE         AND CODE CASB                     AND CoDB CASB          SYMBOL/               MANUFACTURER/

OLD COMPONENT ASHE SERIAL NO. NB NO. YEAR NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI NUTS II B31.1 1967 B31.7 1969 831.7 1969 ALLIED 1991 BOLTS II II

                                               "                II              II             II        .                           ALLIED 1991
     'OL.D)                   A-.5\-11e              A.6We"                           A.SWE                      NOT                M   W kEL/.L>GG

..S/*.SLV'*&.q 7I. Tff flt&l3 nL 19ut3 :m: I~ STAl-IPt5P 1q~9 AfSN/e *--*- ~

                                                                                        ~

co<..a.) 1AS4a- NdT MW~IELL...OGG -.!!!ii-SI- \I-GO IC 7lr 19'£> Ttr ~Cd3 -:or l~G:e> '.5T.AHP6D ,~-r> 7U77 Cot..O)

                              ............           ,.....,___,. .. w '"'--           A
                                                                                      ,.....- .   **-             /VOT              MWkeLLOGG
!51- _e;1 _V-  -~LL     E    ("11i~          I~           'III..             lctl'ii3    III"         19~ ST.4}/Per::>                    !9Co°I
  • CODB JOB PACT
                                                      *   .COVER CONTJ:l!IU'l'ATJ:Olf SBBB'l' P°-¥ ar:R(O CJP HO.: P-91-067 DATB:JANVARY 11, 1992 PAGB        2F OP~~7~

RBVJ:SJ:ON :~~__;O~~~ UNIT: SALBH 1

 #11 AHO #12 FCU SUPPLY ' RBTURH WORKING COPY CJP                                W.O. N0.:910913101 DES. CODE & YR. FAB. CODE & YR. INST. CODE & YR. CODE AND CODB CASE     AND CODE CASE     AND CODE CASE      SYMBOL/                    MANUFACTURER/

OLD COMPONENT ASME SERIAL NO. NB NO. YEAR NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI NUTS II 831.1 1967 B31.7 1969 B31.7 1969 ALLIED 1991 . BOLTS " " II

                                              "       II      II
                                                                       "                                 ALLIED 1991
      *-                                 CODE JOB P *       -~  COVER COH'l'ZHUTATZOH SRBET    pac.µ. !C'C'f' CJP HO.: P-91-067
                                                                                                              /D-*

DATB:JAHUARY 11, 1t92 PAGE 2 OP 7 WORKING COPY CJP RBVZSZOH:~~-..:0~~~ W.O. H0.:910913101

#11 PCU SUPPLY
  • B-453-1, H-454, H-455 ***EHG., SPEC.: S-C-MBOO-KDS-043 Ii SGS/ll-PD-1 DES. OODB & YR. FAB. CODE & YR. INST. CODE & YR. CODE AND OODB CASE AND CODE CASE* AND CODE CASE SYMBOL/ MANUFACTURER/

OLD COMPONENT ASME SERIAL NO. NB NO. YEAR NEw COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI . ANSI ANSI PULLMAN KELLOGG RD-l-SW-272 II B31.1 1967 831.7 1969 B31.7 1969 1979 1-SW-P-6494

  • II
                  "        "       "         "                  "        "                             CONNEX 1991 PULLMAN KELLOGG II      II RD-1-SW-273       "        "       "                             "       II 1973
  • II CONN EX 1991
  • l-SW-P-6495 "

H

                                   "         II lP-SWA-PS-49      II
                           "       "         II
                                                     "           II      II UE&C 1974
***
  • II PSE&G 1992 lP-SWA-PS-49 II II
                                   "         "                   II      II PULLMAN KELLOGG RD-1-SW-273       II
                           "       "         II      II          II
                                                                         "                              1973
  • II II 1-SW-P-6496 91
                           "       "                             "       "                             CONN EX 1991 PULLMAN KELLOGG II                II          II RD-l-SW-273       "        "                 "                           "                              1973 1-SW-P-6497       "
                           ..      II
                                             "       II
                                                                 "       "                             CONNEX 1991 1-SW-274          ..       II
                                   "         II      II          II PULLMAN KELLOGG 1974
  • II II II CONNEX 1991 1-SW-P-6497 " " " II MASONE I LAN 11-SW58(AA-105) II DRAFT P&V 1968 DRAFT P&V 1968 II
                                                                         "     N-00113-37-1 N-857       1975 11-SW58(AA-105)   II
                           "       II        II      II          II
                                                                         "          II        II RELOCATED 1992 ANSI              ANSI                                                           PULLMAN KELLOGG 1-sw-212-1        "    831.1      1967   831. 7     1969         II      II 1979 II                  II      II                II
                  "                          II                  II      II DELETED 1992

FORM NR*1 REPORT OF REPAIR 0 MODIFICATION.jll OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of .J

1. Work performed by p11bl j c Spnrj aa Electric & C'y.5 Co. - Nuclear Ippt. CJP #P91-068 (name) (repair organization's P.O. no., job. no.,etc.)
  • Foot of Btrt+/-t>Tl!t10Crl 'Rood, Hancxx=:kg Bridge.. NI 08038 (address)

(name) Foot of B.rt:tonwpcrl Road, Hancocks Bridge, N.1 08038 (address)

3. Name, address and identification of nuclear power plant _ __.Sal.._...em_.'-"'Nuc....,,...l..,ea,.....rk--:Genera=o.=-=..,,t,,,ing....,,._,sta==t=i::::on,._.___,Uni==-*t"""-.#=1~----- ..

Fcxrt: of Btrt:tonwrxrl Bo.3d, Haryxx:ks Bridge, NI 08038

4. System _ __.Se....,_.TV'-lr..1...,'ce.,...._Wuri...t...,..e...

r __________________________~Nuc~::!l.,,ea==r:.........:C:::l,,,as=s:::........:I::I=--

5. a: Component repaired, modified or replaced -:f... 1...1..,.,...,12~~Co.w1.nt.l.Wi:a..,j..,,T[!ffit.JW!~---...Fani,;.wo~Co!odi;!.il
                                                                                                                                                                   ...' ..._Uni:!o!Lj.*~tss__.sPene~!!o<.!!tra"""--!:~t,...i~on~_,P!:...:1=i'p~irg::!::'
                                                                                                                                                                                                                                                   ~------

b: Name of manufacturer _ _J?SE ............&G~------~----------------'$1JRX'-""lt"L"_...ri:s...-~&........Haa;iers,,_.._ _______ c: Identifying nos. See Attachments See Attachments (mfr's. serial no.) (Narl.Bd.No.) Ourisdictional no.) (other) (year built) d: Construction Code ANSI B.'.31. 7 1969 1970 N/A ANSI B31.1 1967 lMLtion) (addenda) (Code Case(s)) (Code Class)

6. Section XI 1983 Strmmer 83 WA (edition) (addenda) (Code Case(s))
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 ~Nµ/A.....____ _

(edition) (addenda) (Code Case(s))

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *1969 1970 N/A
                                                                                                *ANSI B31. 7/MiSI B31.1 1967 Ed.                                                                       (edition)                     (addenda)               (Code Case(s))
9. Design responsibilities __..ic:.;z.i.:.1111i.z___ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
10. Tests conducted: hydrostatic O pneumatic O design pressure O **pressure 't\/A psi Code Case(s)_~N,..../~A_ _ _ _ __
11. Description of work Modified supports and han;iers to aq :qno7ate new piping design.
 *                                                                                                     (use of additional sheet(s) or sketch( es) is acceptable if property identified)

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. ,- Certificate of Authorization no.

  • 36 to use the "NA" stamp expires
  • Oct. 3, , 19 94 Date 9 - S' 19,~. Signed_ _PSE __ &G_eo_._-_Nuc __lear _ _D:!pt _ _* __ Principal En:1r (repair organization) (authorized representative) (title)

CERTIFICATE OF INSPECTION _I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by ' Co of MA have inspected the repair, modification or replacement described in this report on , 19 t'Vand state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, 9

   - expressed or implied, concerning the repair, modification or replacement described in this report Furthermore, neither the Inspector nor his employer shall be liable in any manner for        any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

VI. 4 ~ £ / ~ Fa~cy Mutual system i

                 £       f    , 1g_!ll:__.                  Signed                t'h~ b~                                                                     Commissions                    A.J;:f"./}J                                                 _            -*
                                                                                    ~             (Inspector)                   .                                            (Nad.Bd.No.(induding endorsements)state or province and number)

This form may be obtained from The National Board of Boller and Pressure Vessel Inspector*, 1055 Crupper Avenue, Columbus, OH 43229. NB-81 Aev.s

P.:'E: COVER CONTIBUTATIOH SHEET ~ ~ 2 of-_3-CODE JOB CJP HO.: P-91-~ DATE:DEC~ER 6, 1991 PAGB 2 OF 7 REVISIOH:~~--.:0~~~ VIORKIN*G COPY CJP W.O. H0.:910913101 DES. CODE & YR. FAS. CODE & YR. INST. CODE & YR. CODE ARD CODE CASE AND CODE CASE

  • AND CODE CASE SYMBOL/ MANUFACTURER/

OLD COMPONENT ASHE SERIAL NO. NB NO. YEAR NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI P-12SWG-28 II Bll.1 1967 BJl.7 1969 831.7 1969 PSE&G 1974 P-llSWG-JlA .. " " " H

                                                   "      "        II PSE&G 1992 P-12SWG-27        "       "       ..        "       "      II       II PSE&G 1974 P-11SWG-32A       "       "       ..        "       "      II       II PSE&G 1992 P-1*4swG-a        "       "       .         H
                                                   "      "        "                       PSE&G 1974 P-12SWG-33A       "       "       "         "       "      "        "                       PSE&G 1992 P-14SWG-7         "       "       .         "       "      "        "                       PSE&G 1974 n

P-12SWG-34A " " " " " II PSE&G 1992 P-llSWH-33 . H

                                 "         "       "      II       II PSE&G 1992 P-llSWH-30        "       "       "         "        "      "       II PSE&G 1992 P-12SWH-32        "       H II PSE&G 1992 P-12SWH-15        "       II
                                 "         "       "      "        ..                       PSE&G 1975 II      II      II
                                           "        II
                                                          "        ..                       DELETED 1992

p**~

  • CODE JOB COVER CON'l!.'INUTATIOH SHEET CJP HO.: P-91-06~

DATE:DECEMBER 6, 1991 PAGE 2A OF RBVISIOH:~~--=O~~~ 7 UNIT~:~-:::.S=AL==BM==--=1~~~ \VOJl{ING COPY CJP *- ...\,lil W.O. N0.:910913101 DES. CODE & YR. FAB. CODE & YR. INST. CODE & YR. CODE AND CODE C:ASE AND CODE CASE_

  • AND CODE CASE SYMBOL/ MANUFACTURER/

OLD COMPONENT ASME SERIAL NO. NB NO. YEAR NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI P-llSWG-27 II BJl.1 1967 BJL 7 1969 BJl.7 1969 PSE&G 1980 II II II II II H II

                                                                                   "                      DELETED 1992 P-llSWG-26               H
                                  "        "         "        "      "             "                      PSE&G 1988 II       II                   II
       "                 "        "        "                         "                                    DELETED 1992 PIPING SPECIALITES II       II     II BEAM ATTACHMENTS          II       H
                                           "                                       "                      1991 PIPING SPECIALITES II                          II HANGER RODS              II
                                           "         "               H
                                                                                   "                      1991 PIPING SPECIALITES H        QI       II        II       H      II            II SPRING CANS                                                                                               1991 WELD LESS EYE                                                                                             PIPING SPECIALITES II       II                 II     II NUTS                     II
                                                     "                             91 1991 PIPING SPECIALITES II       II       II        II       II     II            H "U"-BOLTS                                                                                                 1991

FORM NR-1 REPORT OF REPAIR D MODIFICATION D OR INSTALLATION OF REPLACEMENT($)!!!! TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

1. wo..x performed by Public Service Electric ' Gas Company - Nuclear Dept. CJP t S-91-070 (n*mel 1re1111ir org*n1za11on*a P.O. no.* job no .. elc.)

Foot of Buttonwood Road, Bancocks Bridge, NJ 08038 18ddressl

2. owner __Pub _ _l_i_c_S_e_r_v_i_c_e_E_l_e.;o...;;.c...:tc.::r...:i~c'-&:;:_~G~ac.::s--'C~o~m=Lpa==nAy_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

(Nme) Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 18ddress)

3. Name. address and identification of nuclear power plant Salem Nuclear Generating Station Unit t 1 Poot of Buttonwood Road, Bancocks Bridge, NJ 08038
4. Identification of system Chemical Volume Control Nuclear Class I I
5. a: Identification of component repaired, modified or replaced, _ __:l=-CV=-=-=l=lc.::6;..._:V:...:a=-1=-v~e'-------------------

b: Name of manufacturer Anchor Darling Valve Co. c: Identifying nos. N/A N/A N/A N/A 1988 (mlr."s serial no.) (Nat'I. Bd. _no.) Ouriadictional no.) (Other) (year bulH)

6. Applicable section(s) XI of ASME Code, 19~ edition, __1_9_8_3e--_ addenda Summer Code Case__N-'/_A _ __
7. Design resoonsibilities _...:P...:S:;.;;E:;;;.!._G-"-'-2------------------------------------
8. Tests conducted: hydrostatic C pneumatic c design pressure C pressure N
  • 0
  • P
  • psi.Syste4m Inservice Test
9. Description of work Replaced bonnet studs and nuts in kind.

(use of addl110NI sheet(*) or sketch(esl Is acceptable ii property identified)

10. Rema~s: _ _ _ _ __,_W_o_r_k_O_r_d_e_r--'1~9_0_1_2_1_1_1~4~0-------------~-~--~-~----

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that all design, material and wol'Xmanship on this Replacement conforms to the applicable section of the ASME Code. <repair, modification°' replacement) Certificate of Authorization no. 36 to use the "N ' s October 319 91 . ~ // Signed PSE&G Nuclear Department Manager-Station QA ~ 1l.t,_ Cre1>11ir org.nizalion) (111111 (Cl.ate) CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission Issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of com* petency issued by the state or province of New Jersey and employed by Arkwright Mutual Ins* Co*

  --=-----.----=-~------of                                     Norwood* MA ave inspected the repair, modification or replacement described in this report on 'l . . 2'G ,   199.Land state that to the best of m                                 owledge and belief, this repair, modification or replacement has been made or constructecruf'accordance with Section XI and                                          o                                   he National Board rules as defined In the publications HB-65 amt NEf.-to2, current editions. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or im*

lied, concerning the repair, modification or replacement described In this report. Furthermore, neither the Inspector nor his employer s~all liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Factory Mutual System Commisslons__AJ,,....,..:::~~3_.?'-'3E'-_________ (Nat'I. Bd. no. (Including endo<Mments) stale or province and number) Thia form may be obtained from Tho N1tlonal Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Awe., Columbus, OH 43229 NM1 Rev.*

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 00 OR INSTALLATION OF REPLACEMENT(S) 0

                       '              TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l off?
1. Work performed by Pllhl ic Sendaa Electric & r..as Co. - Nuclear Dept. CJP #P91-071Rev.7 (name) (repair organization's P.O. no., job. no.,etc.)

Foot of &rttonwocrl Road, Hancocks Bridqe, NJ 08038 (address) (name) Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 (address)

3. Name, address and identification of nuclear power plant salem Nuclear Generati.n:J Station Unit #1 Foot of &rttonwocrl Road.. Hancocks Bridge, NJ 08038
4. System Service Water Nliclear Class II 5.a: ComponeMrepa~oo.mooffiedorre~a~ ~#~1~3~1~1~4~*~1-5~~~n~~~~-*~~t~~~~~~~~~~~~*~t~,~~~~~~~t=i~o~n~P~i~P~~~~&~-~

b: Nameofmanufacrurer _ _~eon~re.-::.v..__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ___.,~""l~~rts"-"'li!---- c: Identifying nos. See Attachmemts WA 1:991 (mfr's. serial no.) (Narl.Bd.No.) (jurisdictional no.) (other) (year built) d: Construction Code AN:SI 831 7 1969 ____1.._9 ....7.L.MO'---- WA II ANSI B31.1 1967 llkfi~on) (addenda) (Code Case(s)) (Code Class)

6. Section XI 1983 --~Sl~DIDieww~r--....18~3.._ _ _ _ _ _ _ _ __ N/A (edition) (addenda) (Code Case(s))
7. Applicable ooition of ASME Cooe Section XI under which repairs, mooifications, or replacements were made: 1983 S83 _N~/A _ __

(edition) (addenda) Saile Case(s))

8. Applicable ooition of Construction Code under which repairs, modifications, or replacements were made: *1969 1970 Attached
                                                           *ANSI B31. 7/ANSI B31.1 l967 Ed./                                                 (edition)           (addenda)          (Code Case(s))
9. Design responsibilities PSE&G PS :El:l;Jg. Spec. S~O-M[S-043 & SGS/M-FD-1
10. Tests conducted: hydrostatic [k pneumatic O design pressure O **Pressure Eg. 2psi Cooe Case(s)_~N./~A~-----
11. Description of work Replaced service water penetration pi.pi.rs with pipirg of new design
    .                                                                         (use of additional sheet(s) or sketch(es) is acceptable ii properly identified) r--~a~nd...._~ma.......,t~:e~r~ia......_l~-------------------------------------------

information. _CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. 36 to use the "NA" stamp expires Oct. 3, , 19 94 __~_._-_Nu_c_l_ear _ _oe_p_t_._ Prin::ipal Engr Date '1'- p 19 * .,. ' - . Signoo. _ _PS_E_&G ~~*.4* (repair organization) (authorized representative) (title) CERTIFICATE OF INSPECTION

 .1. the undersignoo, holding a valid commission issuoo by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of             New        Jersey .        and employed by            ** * **
  • Arkwright Mutual Insurance ~

of MA have inspected the repair, modification or replacement described in this report on 5- J't , 197 J-- and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty,

         .                                                 9                                .

expressoo or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be li8:~1e in any manner for any personal injury or property damage or a loss of any kind arising from or connec!OO with this inspection.

                                                                                                                                              ~ctory Mutual System Cf-//        , 19 '1 z,., . Signoo               ~               [.    ~                                  Commissions      A.JJ J 7J                                          i
       *                                        .                          (Inspector)                                       (Natl.Bd.No.(induding endorsements)state or province and number)

Thia form may be obtained from The National Board of Boller and Pressure Vessel lnspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB*81 Rev.6

Page 2 of f"I CJP # P91-071 Rev. 7

  • Construction Code, Code Cases N-453-1, N-454 and N-455 Test No. Component Pressure Temp.
 #2          #13 CFCU Supply & Return        305 PSI         80.4°F
             #14 CFCU Return
             #15 CFCU Supply & Return
 #4          #14 CFCU Supply                 310 PSI
  • CODE JOB PAC.OVER CONTINUTATION SHEET PAGE P*<;e CJP NO.:

2 3& 17 P-91-071 DATE:Decembe~ 17,1991 OF . 7 OHIT~:~----.S=AL EM--...=1~~~

  1. 13 P'CU SUPPLY - -. -
                                         *H 453 1 H 454 I H DES. *coDE & YR.

FAB. CODE & YR. INST. CODE & YR. CODE AND CODE CASE* AND CODE CASE

  • AND CODE CASE .. SYMBOL/ MANUFACTURER/

OLD COMPONENT ASME SERIAL NO. NB NO. YEAR NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI CATALYTIC l-SW-P-1116 II B31.l 1967 B31.7 1969 B31.7 1969 1985 l-SW-P-6529 " " " * " " " " CONNEX 1991 PULLMAN POWER l-SW-141H-R " " II II

                                                                "      "        II 1973 l-SW-P-6529               "        "         "    *    "         II     II       II CONNEX 1991 PULLMAN KELLOGG l-SW-141F                 "        II
                                            "          "        "      "        "                         1973
    "                    ..       II
                                            "          "        II
                                                                       "        "                        DELETED 1992 PULLMAN KELLOGG l-SW-141A                 "        "         "          "        "      "        "                         1973
    "                    "        "         "          "        "      "        "                        DELETED 1992 PULLMAN KELLOGG l-SW-141B                 "        "         "          II
                                                                "      "        "                         1975
    "                    ..       "         "          "        "      "        "                         DELETED 1992 PULLMAN KELLOGG RD-l-SW-1418-1            10
                                  "         "          "        "      "        "                         1975 II II                   II
                                  "                    "        "      II
                                                                                "                        DELETED 1992 PULLMAN KELLOGG 1-SW-141C                 "        "         "          "       ... HI
                                                                                "                         1973 1-SW-P-6530               "        "         "    *     "        "      "        "                         CONN EX 1991 PULLMAN KELLOGG l.-SW-141E
                         "        "         "          "        "      "        "                         1973 1-SW-P-6530               "        "         "
  • II II II II CONN EX 1991
     **                                CODE JOB PAC. COVBR COll'l'IHU'l'ATIOll SHBBT PAGB
                                                                                              ~~ t.-f of 2A OF l

CJP 110.: P-91-071 7 DATB:December 17.1991 7 WORKING COPY CJP RBVISIOll:~~---0~~~ w.o. 110.:910913118

  1. 13 PCU SUPPLY *11-tsl-1. 11-454. 11-455 ***BllG. SPBC.18-C-llBOO-MDS-043 6i SGS/N-PD-1 DBS. CODB &'YR. FAB. CODE 6i YR. INST. .CODE 6i YR. CODE AHi> CODS CASE AND CODE CASE
  • AND CODE CASE SYMBOL/ MANUFACTURER/

OLD COMPONENT ASHE SERIAL NO. NB NO. YEAR

  • NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI PULLMAN KELLOGG 1-SW-141-D II 831.1 1967 831.7 1969 B31.7 1969 1973 1-SW-P-6530 " " " * " " " " CONNEX 1991 PULLMAN KELLOGG RD-1-SW-142 " " ". II II
                                                                 "          "                              1973 II                                                 CONN EX 1991 1-SW-P-6531       "        "        "     *     "                 "          "
      • ,, n
                                               "        "        II
                                                                            "                              UE&C 1974 lP-SWA-PS-48               "
      • II II PSE&G 1992 lP-SWA-PS-48 " " " * " " PULLMAN KELLOGG
                                                                            "                              1973 RD-1-SW-142       "        "        "           "        "        "

n CONN EX 1991 1-SW-P-6532 " " " * " " "

        --~-

PJI.. 1 CODB JOB COVBR COlll'UllU'l'ATIOll BRBB'l' 0.lle S of' ) .* CJP HO.: P-91-071 DATB:December 17,1991 PAGB 28 OP 7 UHIT~=~-=SAL====BM=-=1~~~

~13 PCU RBTURll WORKING COPY CJP                                            RBVISIOH:~~~O,.__~~

W.O. H0.:910913118

                           *N-453-1. N-454. N-455 ***ENG. SPBC.aS-C-llBOO-llDS-043 ~ SGS/N-PD-1 DES. CODE & YR. FAB. CODE & YR. INST. CODE & YR. CODE AND OODE CASE       AND CODE CASE
  • AND CODE CASE SYMBOL/ MANUFACTURER/

OLD COMPONENT ASME SERIAL NO. NB NO. YEAR

  • NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI PULLMAN KELLOGG RD-l-SW-171 II 831.1 1967 BJl.7 1969 BJl.7 1969 1973 l-SW-P-6523 II II II II
                                                          "      II         II CONNEX 1991 RD-1-SW-171          II      II       II         II       II     II         ..                              PULLMAN KELLOGG 1973 II l-SW-P-6524          II       II      II II     II         II CONN EX 1991 lP-SWA-PS-53                  n       II II
                                                  "       II     II
                                                                            "                               UE&C 1974
***                                   II                         II lP-SWA-PS-53         II
                              "             *    "        II                II PSE&G 1992 PULLMAN KELLOGG II RD-1-SW-172D         ti       II
                                      "                   II
                                                                 "          II 1973 II l-SW-P-6525          II
                              "             *    "        II
                                                                 "          "                               CONNEX 1991 PULLMAN KELLOGG II RD-l-SW-172C         "        II
                                      "                   "      II         II 1973 II l-SW-P-6525          "        "       II
                                            *             "      II         II CONN EX 1991 PULLMAN KELLOGG II                  II, RD-1-SW-172C         II       II
                                                  "              II         II 1973 II 1-SW-P-6526          II       II      II II      II                II CONNEX 1991 PULLMAN KELLOGG II             H l-SW-172E            II       II      II                  II                II 1973 II II
                     "        "       "                   II     II         II DELETED 1992
  • CODE JOB PAC. COVER CONTINUTATION SHEET rag-e b .:.*-*

17 CJP NO.: P-91-071

  • DATE:December 17,1991 PAGE 2C OF 7 I

I 1 WORKING COPY CJP REVISION:~~---.0~~~ W.O. N0.:910913118 I 13 P'CU RETURN *N-453-1. N-454. N-455 DES. CODE & 'YR. FAB. CODE & YR. INST. CODE & YR. CODE ARD OODB CASE AND CODE CASE

  • AND CODE CASE SYMBOL/ MANUFACTURER/

OLD COMPONENT ASME SERIAL NO. NB NO. YEAR NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI PULLMAN KELLOGG 1-SW-1728 II 831.1 1967 831.7 1969 831. 7 1969 1973 II

       "          "       "        "          "                "        "                       DELETED 1992 PULLMAN KELLOGG RD-l-SW-172A       II      II
                                   "          II
                                                      "        "        II 1974
       "          "       "        II         II
                                                      "        "        II DELETED 1992 PULLMAN KELLOGG 1-SW-172H         "       II
                                   "          II
                                                      "        IO
                                                                        "                       1973 II         II
                          "        "          "       "        IV
                                                                        "                       DELETED 1992 PULLMAN KELLOGG II RD-1-SW-172A-1     II
                          "        "          "       "        "                                 1974
       "          II
                          "        ..         "       "        "        "                       DELETED 1992 PULLMAN KELLOGG 1-SW-172G         "       "        "          "       "        "        "                       1973 1-SW-P-6526       "       "        "    *     "       "        "        "                       CONN EX 1991 PULLMAN KELLOGG RD-1-SW-172-1     "       "        "          "       "        "        II 1976 1-SW-P-6526       "       II
                                   "    *     "       "        "        "                       CONNEX 1991 PULLMAN KELLOGG RD-l-SW-172       "       II
                                   "          "       "        "        "                        1976 1-SW-P-6526       "       "        "    *     "       "        "        "                        CONN EX 1991
  • CODE JOB PAC. COVER COMTINUTATION SHEET pqge -, a.P. \ -7 CJP NO.: P-91-071 DATB:December 17,1991 WORKING COPY CJP PAGB 2D OF 7 REVISIOH:~~-0~~~

W.O. H0.:910913118 UHIT~:~-=S=AL==EH=--=1~~~ ~13 FCU RETURN *N-453-1. N-454. N-455 DES. CODE &'YR. FAB. CODE & YR. INST. CODE & YR. CODE ARD CODB CASE AND CODE CASE

  • AND CODE CASE SYMBOL/ MANuFACTURER/

OLD COMPONENT ASME SERIAL NO. NB NO. YEAR

  • NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI PULLMAN KELLOGG RD-1-SW-172-2 II 831.1 1967 831.7 1969 BJl.7 1969. 1976
  • II II II CONN EX 1991 1-SW-P-6526 " " " "
  • CODB JOB P A . COVER CO!l'l'INUTA'l'ION SHBB'l' ~c>>~ ~ M ~)

CJP NO.: P.-91-071 DA'l'B:December 17,1991 PAGE 2E OF 7 UNI'l'~:~-=SAL===Bll=--=1~~~ WORKING COPY CJP RBVISION:~~-0'"--~~ W.O. N0.:910913118

#14 P'CU SUPPLY DES. CODE.& YR.       FAB. CODE & YR. INST.. CODE & YR. CODE ARD OODB CASE         AND CODE CASE       AND CODE CASE      SYMBOL/                  MANUFACTURER/

OLD COMPONENT ASME SERIAL NO. NB NO. YEAR

  • NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR INI 191111 MAJlCH'lO MAllCH'lO MASONE I LAN INT.

14SW58(AA-105) II DRAFT P&V DRAFT P&V It 1969 N-00113-37-4 N-857 1975 14SW58(AA-105) It It It It It It H

                                                                                               ,,           .,    RELOCATED 1992 ANSI                 ANSI                 ANSI                                      PULLMAN KELLOGG RD-R-l-SW-182A-3              831.1       1967      831.7        1969   831.7       H 1975 II        It          II           It   It        It It
                        "                                                                                         DELETED 1992 PULLMAN KELLOGG RD-R-1-SW-182A          "         II        II          II           II   It        II 1975 II            II        H         II          It
                                                                     "    II        II DELETED 1992 PULLMAN KELLOGG 1-SW-182-5              II        II        II          II           n    II        II 1975 II            II        II        It          II
                                                                     "    II        II DELETED 1992 PULLMAN KELLOGG II        II          II           II   II        II 1-SW-182-4              II 1975 II        II          II           II   II II
                        "                                                           II DELETED 1992 PULLMAN KELLOGG It          It           II 1-SW-182-3              "         "                                       "         II 1975 It                       II II            It        II                    II                It        It DELETED 1992 PULLMAN KELLOGG It 1-SW-182-2              "         II
                                            "           II           It   II 1975 II           II II
                        "         "         "                             "         It DELETED 1992
  • CODB JOB P . E COVBR COJl'l'XlllUTATXOll BRBll'l' P"'<!< 1 °1 '7
  • CJP HO.: P-91-071 DATB:December 17.1991 PAGB 2P OP 7 WORKING COPY CJP RBVISIOH:

W.O. H0.:9109131{8 0 .

  1. 14 PCU SUPPLY *H-453-1. H-454. N-455 ***ENO. SPBC.18-C-llBOO-MDS-043 ~ 808/N-PD-1 DES. CODE.& YR. FAB. CODE & YR. INST. CODE & YR. CODE AHO CODB CASE AND CODE CASE
  • AND CODE CASE SYMBOL/ MANUFACTURER/

OLD COMPONENT ASME SERIAL NO. NB NO. YEAR NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI PULLMAN KELLOGG 1-SW-184 II B31.1 1967 B31.7 1969 B31.7 1969 1973 n II

  • II CONNEX 1991 1-SW-P-6507 II PULLMAN KELLOGG 1-SW-184 " " II II
                                                    "       "         "                               1973
  • II CONNEX 1991 1-SW-P-6508 II PULLMAN KELLOGG 1-SW-184A II
                        "        II
                                           "        II
                                                            "         "                               1973 u       II       II
  • II II II CONNEX 1991 1-SW-P-6508 " PULLMAN KELLOGG II RD-1-SW-185 II II II
                                            "       "                 "                               1974 1-SW-P-6509      .       II
                                            "       "       II        II CONN EX 1991
      • II II UE&C 1974 lP-SWA-PS-47 ti 01 II
      • II
  • II II II PSE&G 1991 lP-SWA-PS-47 II H PULLMAN KELLOGG II II 01 RD-1-SW-185 II
                        "        "                          "                                         1974
  • II II CONNEX 1991 1-SW-P-6510 " II PULLMAN KELLOGG 1-SW-186 II H II
                                            "       "       "         H                               1973
  • II II II CONN EX 1991 1-SW-P-6510 II 10
  • CODB JOB P . ' . B COVBR COJITillU'fllTIOR BBBBT P<'l" '"'°7
  • CJP HO.: P-91-071 DATB:Decellber 17,1991 PAGB 2G OP 7 WORKING COPY CJP RBVXSXOH:~~-=-0~~~

W.O. M0.:910913118

  1. 14, FCU JlBTURJr *H-453-1. l-411ii4. *~411iillii. * * * -.. an*lll as-c-NBOO-llDS-043 Ii SGS/11-FD-1 DBS. CODE'& YR. FAB. CODE & YR. INST. CODE & YR. CODE MD CODB CASE AND CODE CASE
  • AND CODE CASE SYMBOL/ MANUFACTURER/

OLD COMPONENT ASME SERIAL NO. NB NO. YEAR NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI PULLMAN KELLOGG RD-1-sw-211 II 831.1 1967 B31.7 1969 831.7 1969 1973

  • It It CONN EX 1991 l-SW-P-6498 "

It It It

      • II II UE&C 1974 lP-SWA-PS-52 It It It It
  • It PSE&G 1992 lP-SWA-PS-52 It It
                                   "             It
                                                                   "                     "                             PULLMAN KELLOGG It      II            II                n         II          It 1973 RD-1-sw-211         "
  • II II n II CONNEX 1991 l-SW-P-6499 It
                           "       "                                                                                   PULLMAN KELLOGG l-SW-212E           Cl      It
                                   "             "                 "         II          It 1973 l-SW-P-6500         DI
                                   .      *      ..                It
                                                                             "           "                             CONNEX 1991 PULLMAN KELLOGG l-SW-2128           It
                           "       It            It                It         It         It 1973 It
  • II H CONNEX 1991 l-SW-P-6500 " " " " PULLMAN KELLOGG l-SW-212B " " "

H H

                                                                                         "                              1973
  • H
                                                                                         "                             CONNEX 1991 1-SW-P-6501         Ii      It PULLMAN KELLOGG 1-SW-212F           "       H
                                   "             II
                                                                   "          H          II 1973
      "            "       II      II
                                                 "                  "         H
                                                                                         "                              DELETED 1992

P*~

  • CODE JOB p *
  • B COVER COll'UllUTATZOJI SHEET CJP HO.:

PAGB II$ 'I

  • P-91-071 DATB:December 17,1991 2H OP 7 UlfIT~:~-=S~AL===EH==-~1=-~~-

WORKING COPY CJP REVISIOH:~~-=-0~~~ W.O. H0.:910913118

  • 14 JPCU RETURN *H-453-1. H-454. H-455 DES. CODE'& YR. FAB. CODE & YR. INST. CODE & YR. CODE AND CODE CASE AND CODE CASE
  • AND CODE CASE SYMBOL/ MANUFACTURER/

OLD COMPONENT ASME SERIAL NO. NB NO. YEAR NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI PULLMAN KELLOGG l-SW-212A .II 831.l 1967 831.7 1969 831.7 1969 1973

       "                "        "       "          "       "        "        "                          DELETED 1992 PULLMAN KELLOGG 1-sw-212D                "        "       II
                                                    "       "        "        II 1973 II II
                        "        "                  II
                                                            "        "        "                          DELETED 1992 PULLMAN KELLOGG 1-sw-212G                "        II
                                         "          II
                                                            "        II
                                                                              "                          1973 II
                                 "       "          "       "        "        "                          DELETED 1992 PULLMAN KELLOGG II               II 1-sw-212c                         "                  ff
                                                            "        "        "                          1973 II
       "                II
                                 "                  "       "        "        "                          DELETED 1992 PULLMAN KELLOGG l-SW-212H               "        "       "          "       "        "        II 1973
                        "        "       II
                                                    "       "        "        II DELETED 1992
       "                                                                                                 PULLMAN KELLOGG II       UI                         II       n RD-1-sw-212                               "          "                         II 1976 l-SW-P-6501             II       H       II ff      II       ff
                                                                              "                          CONN EX 1991
                                                                                                    ~ <'- "' '-,
  • CODB JOB . . . . . . COVBR cmrr:nnrl'AUOll BRBBT CJP HO.:

PAGE P-91-071 DATB:December 17,1991 2I OP 7 UlfIT~=~--=S=AL==EM=-=1~~~ WORKING COPY CJP RBVISIOH:~~---"-0~~~ W.O. H0.:910913118

  1. 15 rcu SUPPLY *N-453-1. N-454. N-455 ***ENG. SPZC.18-C-MBOO-llDS-043 ~ SGB/K-l"D-1 DES. CODE 61 YR. FAB. CODE & YR. INST.. CODE & YR. CODE AMI> CODE CASE AND CODE CASE
  • AND CODE CASE SYMBOL/ MANUFACTURER/

OLD COMPONENT ASME SERIAL NO. NB NO. YEAR NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR II 15SW58(AA-105) II ASME III ASME III 1969 15SW58(AA-105) II

                                "        "          .       "             II       II RELOCATED 1992 ANSI              ANSI                      ANSI                                  PULLMAN POWER RD-l-SW-221A          II BJl.l       1967    BJl.7       1969        BJl.7       II 1979
  • II II II CONNEX 1991 l-SW-P-6481 ti II PULLMAN KELLOGG RD-1-sw-221 " " " " II
                                                                          "        II                        1976
  • II II CONN EX 1991 1-SW-P-6481 II II
                                         "          "                     "                                  PULLMAN KELLOGG II            II RD-1-sw-221           II
                                "        "          "                              II 1976
  • II CONN EX 1991 1-sw-P-6482 II
                                "        "          "                     "        II PULLMAN KELLOGG i        II RD-1-SW-2218          "          II       II
                                                    "       II
                                                                'I
                                                                                   "                         1973
  • II CONN EX 1991 l-SW-P-6482 II
                                "        "          "       "                      II                  -

PULLMAN KELLOGG II RD-1-SW-222 II

                                "        "                  II
                                                                          "        II 1975
  • CONN EX 1991 1-SW-P-6483 II II
                                                    "       II            II
      • II II UE&C 1974 lP-SWA-PS-46 II II
                                         "                  "                      II
      • II
  • II II II PSE&G 1992 lP-SWA-PS-46 II II
                                                                .TER
  • CODE JOB PACJtAf COllTIHUTATIOH SHEET P<<4e l ~ crf 1 -,

CJP HO.: P-91-071 DATB:pecember i7,1991 PAGB 2J OF 7 UNIT~:~-=S~AL==EH=-~1:.__~~ WORKING COPY CJP REVISIOH:~~---=-0~~~ W.O. H0.:910913118

  1. 15 PCU SUPPLY *N-453-1. N-454. N-455 DES. CODE ' YR *. FAB. CODE & YR. INST. CODE & YR. CODE AND CODB CASE AND CODE CASE
  • AND CODE CASE SYMBOL/ MANUFACTURER/

OLD COMPONENT ASME SERIAL NO. NB NO. YEAR NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI PULLMAN KELLOGG RD-1-SW-222 II B31.1 1967 B31.7 1969 831.7 1969 1975 1-SW-P-6484 II II

  • II II II
                                        "                                      II CONNEX 1991 PULLMAN KELLOGG l-SW-222A              H        II
                                        "           II      II
                                                                     "         "                           1973 II
  • II II 1-SW-P-6485 II II
                                                    "       "                                              CONN EX 1991
  • CODI! JOB P A C . COVBR CO!l'l'IMU'l'A'l'IOM SBBB'l' ~bq-e I'-(

CJP MO.: P-91-071 c.>t* t 7 DA'l'B:December 17,1991 WORKING COPY CJP PAGB 2K OP RBVISIOM:~~--.0~~~ W.O. M0.:910913118 7 '15 rcu ~

  • 11-453-1. 11-454. 11-455 ***BllG. 8PBC.18-C-MB00-11D8-043 & 808/11-P'D-1 D&S. CODE &'YR. FAB. CODE & YR. INST. CODE & YR. CODE AND CODE CASB AND CODE CASE
  • AND CODE CASE SYMBOL/ MANUFACTURER/

OLD COMPONENT ASME SERIAL NO. NB NO. YEAR

  • NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI PULLMAN KELLOGG RD-1-SW-227A II 831.1 1967 831.7 1969 B31.7 1969 1973
  • CONN EX 1991 1-SW-P-6472 "

II

***                                                                                                          UE&C 1974 lP-SWA-PS-51     "       "        "           "        II lP-SWA-PS-51     II      II       H           II       II       II        II                                 PSE&G 1992
  • PULLMAN KELLOGG II
                                                                "         II                                 1973 RD-1-SW-227       "       "        "                    "

1-SW-P-6473 II

                         "        "           II       II
                                                                "         II CONNEX 1991
  • PULLMAN KELLOGG l-SW-2288 " " " " " " II 1973 1-SW-P-6474 " II II
                                                                "         II CONNEX 1991
  • PULLMAN KELLOGG RD-l-SW-228 II
                         "        "           "        "        "         "                                  1976 1-SW-P-6474      II
                         "        II          II       II       H         II CONN EX 1991
  • PULLMAN KELLOGG RD-1-SW-228 II
                         "        II          II       II       H         II 1976 1-SW-P-6475      II      II       II          II
                                                       "        et        II                                 CONNEX 1991
  • PULLMAN KELLOGG II II II II DI II 1976 RD-1-SW-228A "

II II 1-SW-P-6475 II II II

                                        *                       "'        II CONN EX 1991
  • CODB JOB PACJU.OVBR COllTIIRJ'l'A'l'IOH SBBB'l' ~ <J.e 1 5' of:! 1-)

CJP KO.: P-91-071 DA'l'B:peceaber 17,1991 PAGB 2L OP 7 UlfI'l': SALBM 1 WORKING COPY CJP RBVISIOH:~~--0~~~ W.O. H0.:910913118

  1. 15 PCU RBTURll DES. CODE 6i YR. FAB. CODE 6i YR. INST. CODE 6i YR. CODE ARD COOS CASE AND CODE CASE AND CODE CASE SYMBOL/ MANUFACTURER/

OLD COMPONENT ASME SERIAL NO. NB NO. YEAR NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR 111181. MAICll'lll 1111111 MAllCH'lll MASONEILAN INT. 15SW72(AA-105) II DRAFT P'V DRAFT P&V II 1969 N-00113-39-S N-857 1974 RELOCATED 15SW72(AA-105) II II

                                          "        II             II
                                                                       "        II
                                                                                             "           "         1992
                                                                                                                   ~~Lb'*17 * .
                    ..                              CODE J O B
  • r * '8 COVER COM'l'IllUTATIOH SHEET CJP 110.: P-?1.-071 DATE: 4*L2* qz WORKING COPY CJP PAGB RBVISIOll:

w.o. 211 OF I H0.:910913118 l URIT; SALBM I

     #13, #It AND #15 FCU, SUPPLY AND RETUIUI DES. CODE G YR.       FAB. CODE & YR.          INST. CODE & YR. CODE lillD CODE CASE       AND CODE CASE            AND CODE CASE        SYMBOL/                 MANUFACTURER/

OLD COMPONENT ASHE SERIAL NO. NB NO. YEAR NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI NUTS II 831.1 1967 831.7 1969 831.7 1969 ALLIED 1991 ANSI ANSI ANSI ~ BOLTS (0(...0_) . II 831.1 A6A.le' 1967 831.7 A..::::'11.Je 1969 831.7

                                                                                         ~-

1969 NOT ALLIED 1991 H. k'~ Sl*SLV- 4~ I£ .:trr I~ 7lC 19tE8 "--r;r 1q~ .:sTAUPt:n I t:!/c,.-;,9 .&*-~/.~LV-( .J d. 7 .. ~KFF.//1Gr A~E

                                                                                 ~~~*       ~

A9/C- Nt!>T I~ ~ c:J '- '-' 7I: .l1I ~*ur IC/fi8 Sl'"AUP0 /9t'et9

.&                                                       ...-.    *~

UW~P.-r/ f

                                                                                ~ R(A!!, .'$"A).IPEO NOi                                    Y--X-(~~...)

_4/fiJ-~1 v-.AA :zr A:.'!5ME

                                   .:or       19~       **Tr-         ~                                                            /q<o<=J            --*

& (O'-Q.)

   ..Sl-..SL v     .. SI    I£ ~life l9Cd!!> A~                        ~-
                                                                      /7CJ'C?     ~           19~ GrAMPeD
                                                                                                         /\k!)T              NW ,.u',,.::?/ . r Y..... (
                                                                                                                                    /qcc,9 I

I I

CODE JOB PACF. COVER CONTINUTATION SHEET ~<l ~ 11 oP t c CJP NO.: P-91-071 DATE:December 17,1991 PAGE 2M OF 7 RBVISION:~~--0~~~ DRU: OLBK 1

  1. 13 * #14 ARD #15 FCU
  • SUPPLY AHD RE'l'URlf DES. CODE & YR.

WORKING COPY CJP FAS. CODE & YR. INST. CODE & YR. CODE W.O. N0.:910913118 AHi> CODB CASE AND CODE CASE AND CODE CASE SYMBOL/ MANUFACTURER/ OLD COMPONENT ASME SERIAL NO. NB NO. YEAR .NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI NUTS II BJl.l 1967 BJl.7 1969 BJl.7 1969 ALLIED 1991 ANSI ANSI ANSI BOLTS II BJl.1 1967 B31.7 1969 :SJl.7 1969 ALLIED 1991

FORM NR*1 REPORT OF REPAIR 0 MODIFICATION l;Xj' OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of.~ 1.wo~perlormedby_....JB~:ib~l~1~*c"'"-.,JSews;;~lY.lL.Li~oe&i...Ewlsectra...i.~i~c........&L...l.r.~..,Ms~eo,.w,.~-::...JNuW.1!C~l*e!lsaa*r--"Dept.s:.t.!l.:.!*'---~CJP~!'-......:#~P9~l~-O~L7~2'------- (name) (repair organization's P.O. no., job. no.,etc.) Foot of Butj:or&lrxrl Bead, Hancx>cks Bridge, NJ 08038

  • (address)
2. Owner _ __..Pub~..,,l""'icl><....!Sety~~1..,*ce..,,,.__.El~ectr~~i~c=-*~am~,_Gas~~~eo~.!.-------------------------

(name) Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 (address)

3. Name. address and identification of nuclear power plant _ _....JSal~ ...em~L*A:Nu~C""'l~ea~Lr!:.......:Gene.ra~~~!..!t,.,:im!::!.!~sta~~t""i~on~---!Uni~=*t~..n#~l,___ _ _ _ __

Foot of ButtonWrxTI Boadg Hancx>cks Bridge, NJ 08038

4. System Service Water Nuclear Class II
5. a: Component repaired, modified or replaced _...#_lx3_,_,...,1""'4_,_,_,.,l,,.S~Containmen=-=""*==.:..:t,,__,,Fan'-=~Co=il=' ='------
                                                                                                                                                   =-Uni==':..:t=--=Pene-==tra=::.::t::i::.::a::n:.:.....;P::...;l.=i'P.::.l.lB='

b: Name of manufacturer _ _psE"""""""'u;....________________________...,J~"""'~"""'rts<...!lo!~',___.Hang~~a::ers:!:.!:~--- c: Identifying nos. See Attacbmexits _________,$ee"""""'-'Attachirents (mfr's. serial no.) (Narl.Bd.No.) OurisdictionaJ no.) (other) (year built) d: Construction Code ANSI B31 . 7 1969 1970 WA ANSI B31.l 1967 EdiJion) (addenda) (Code Case(s)) (Code Class)

6. Section XI 1983 Sunmer 83 WA (edition) (addenda) (Code Case(s))
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 ~N......
                                                                                                                                                                                                                                       /A~--

(edition) (addenda) (Code Case(s))

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *1969 1970 N/A
                                                                            *ANSI B31. 7 /ANSI B31.1 1967 Fd. (edition)                                                                               (addenda)                    (Code Case(s))
9. Design responsibilities ......ll::IO!.IOl2'!iZ...-------------:---------------------------
10. Tests conducted: hydrostatic O pneumatic O design pressure O **pressure WA psi Code Case(s)_"""N=.....,/A~------
11. Description of work Mcxlified supports an:l barge.rs to aocaood.ate new pipioo design.

(use of additional sheet(s) or sketch(es) is acceptable if properly identified) e~~~~~~~~~-

12. Remarks: _ _...,w~a~r~k.._..Qrr1 .......~e~r~#iF--'~9~1~n~9~1~1~1~1~a'----~-------JDel.&Of .......

ic i~e.DC¥~a.qc...i.:Re~po.a.J,lrt....._~#~:L......l?\~/uAc:a..__ _ _~-~~- Design Olan;Je Package #: lEC-3053 Pkg. 1 See attached pages for Description of Replacement. N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no.

  • 36 to use the "NA' stamp expires Oct. 3, , 19 94

_ _Dept __ *- ,,..J,a~- Principal En;Jr Dat~9- fl 19,.....f..h_. Signed._ _ PSE_&G_eo_.-_Nu_c_lear (repair organization) (aulhorized representative) (title) CERTIFICATE OF INSPECTION _I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwri t Mutual Insurance Co of MA have inspected the repair, modification or replacement described in this report on and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty,

                                                                              //

expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. 9 I . Facto!Y Mutual System

        ,_C[_,_,_'...,1f----, 19'J1.,.;.               Signed(P!ldl$r         7.     ~                                           Commissions                    )/;:£] 1J                                                                   /

(Inspector) (Nat!.Bd.No.(induding endorsements)state or province and number) This form may be obtained from The National Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB-81 Rev.6

  • CODE JOB PACF. *OVER CONTINUTATION SHEET
                                                                             ..*.. ~ .. :.~

{~gel.of'~ 2 OF REVISION:~~--0~~~ 7

                                                                                                                       }.
  • CJP NO.: P-91-07:0::-

DATE:DECEMBER 11,1991 PAGE URIT~:~--=S=AL==EH=-~1'--~~ YIO:?KING COPY CJP **~

                                                                                             ...'l W.O. N0.:910913118 DES. CODE & YR. FAB. CODE & YR. INST. CODE & YR. CODE AND OODB CASE     AND CODE CASE    AND COD.E CASE         SYMBOL/                      MANUFACTURER/

OLD COMPONENT ASME SERIAL NO. NB NO. YEAR NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI - ANSI P-15SWG-8 II BJl.1 1967 BJl.7 1969 B31. 7 1969 PSE&G 1974 II P-lJSWG-13 " " " " " " PSE&G 1992 P-15SWG-7 " " " ". n

                                                                "         ..                                     PSE&G 1974 P-lJSWG-:14            "       "        "        "        II
                                                                "         II PSE&G 1992 P-lJSWG-8              "       "        "        "        "      "         ti PSE&G 1974 P-14SWG-19             "       "        II
                                                "        "      "         ti PSE&G 1992 P-lJSWG-6              "       "        "        "        "      "         "                                      PSE&G 1974 P-14SWG-20             "        "       "        It
                                                         "      "         "                                      PSE&G 1992 P-llSWG-25             II
                               "       It
                                                "        "      "         II PSE&G 1974 P-15SWG-14             "       "        "        "        "      "         ti PSE&G 1992 P-llSWG-24             "       "        "        "        "      "         ti PSE&G 1974 P-15SWG-15             "        "       "        "        "      "         "                                      PSE&G 1992 P-lJSWH-12             H
                               "       "        "        "      "         "                                      PSE&G 1992 P-15SWH-16             II
                              "        "        "        "      "         "                                      PSE&G 1992
  • CODE JOB PAC'. COVER CONTillUTATIOll SHEET fct'!f2 '.,of ')
  • CJP NO.: P-91-072 DATE:DECEMBER 11,1991 PAGE 2A OF REVISIOH:~~___:;O~~~

7 w,o. H0.:910913118 UHIT~:~-=S=AL==EM=-=1~~~ DES. CODE &*YR. WORKING COPY CJP FAB. CODE & YR. INST. CODE & YR. CODE AND CODB CASE AND CODE CASE AND CODE CASE SYMBOL/ MANUFACTURER/ OLD COMPONENT ASME SERIAL NO. NB NO. YEAR

  • NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI P-13SWH-15 II 831.1 1967 B31.7 1969 B31.7 1969 PSE&G 1992 P-14SWH;..21 II II n II II II II PSE&G 1992 n II P-15SWH-16 II
                                    "         "             II       It PSE&G 1992 II      II             II P-13SWH-3            "       "       II                      Bl PSE&G 1975
     "--'          II       II      II        II      II    OI
                                                                     "                              DELETED 1992 P-13SWH-4            "       II
                                    "         II
                                                      "     "        II PSE&G 1975 II
                    "       II
                                    "         ..      II    II       II DELETED 1992 P-14SWH-3            "

II II II II PSE&G 1975 II II II II II II

                                                            "        "                              DELETED 1992 II P-14SWH-4            "       II      II
                                                      "     "        II PSE&G 1975
     "              II      II
                                    "         "       "     "        "                              DELETED 1992

pa. ~-e

  • CODE JOB PACF.COVER CONTINUTATIOH SHEET L/

CJP HO.: P-91-072 crf DATE:DECBHBER 11,1991 PAGE 2B 01'_~7__ 5* RBVISIOH: _ _~O--~ WORKING COPY CJP ....* *...:. W.O. H0.:910913118 DES. CODE & YR. FAB. CODE & YR. INST. CODE & YR. CODE AND OODB CASE AND CODE CASE AND CODE CASE SYMBOL/ MANUFACTURER/ OLD COMPONENT ASME SERIAL NO. NB NO. YEAR NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI P-14SWH-5 II 831.1 1967 831.7 1969 831.7 1969 PSE&G 1975

     ..            ..     .        ...      ..       ..    ..                ..                       DELETED 1992 P-14SWH-6           .      .         "       ..       "     H
                                                                             "                         PSE&G 1975
     "             "      "         "       ..       .. Ill               ..                        DELETED 1992 P-13SWG-SA,SB, SC   .      "         .        ..      n     ..                ..                        PSE&G 1991
     ..            .. II        II       II
                                                     "     II                II DELETED 1992 P-13SWG-7B          "      II        II       II
                                                     "     "                 II PSE&G 1991
     "             "       II       II
                                             "       "     .                 II DELETED 1992 P-14SWG-10B         "       "        II       II
                                                     "     "                 II PSE&G 1988 II       II
     "             "       II
                                                     "     "                 II DELETED 1992 SPRING CANS         ..      II       II       II
                                                     "     II                II PIPING SPECIALTIES 1991 BERGEN PATERSON "U"                                           II                                                        1991 BOLTS          II      II       II
                                                     "     "                 II

p<r~t' S a-I 5 . *

  • CODE JOB P A c e COVER COllTillOTA'l'IOJI SRBB'I' CJP NO.: P-91-072 DATB:DBCEH8ER 11,1991 PAGB 2C OP 7 REVISION: 0
                                                                         ***:~

W.O. N0.:910913118 WORKING COPY C.Pi DBS. OODB & YR. FAB. CODE & YR.

                                                                         .* *.~..-:&

INST. CODE & YR. CODE UD CODB CASB ARD CODE CASE ARD CODE CASE SYMBOL/ MANUFACTURER/ OLD COMPONENT ASME SERIAL NO. NB NO. YEAR

  • NEW COMPONENT CLASS CODE YEAR CODE YEAR CODE YEAR ANSI ANSI ANSI PIPING SPECIALITES HANGER RODS II 831.1 1967 831.7 1969 831.7 1969 1991 PIPING SPECIALITES NUTS II II II
                                             "        "     II       II 1991 WELDLESS EYE                                                                                        PIPING SPECIALITES NUTS                "      "        "         "       "     "        "                              1991 BEAM                                                                                                PIPING SPECIALITES ATTACHMENTS    .. II
                            "       "         "       "     II       II 1991

FORM NR*1 REPORT OF REPAIR D MODIFICATION~ OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of 3 1 Work performed by p11bl i c Send oa El ectrj c & C'..as Co. - Nuclear Dapt

  • CJP #P92-010
        *                                                                                               (name)                                  (repair orgamzanon*s P .0. no .. job. no ..etc.)

Foot of &JttoDSeD"rl Road. Hancoc:ks Brjdge, NJ 08038 (address) (name)

             . Foot of Buttonwood Road,                              Hanccx:ks Bridge, NJ                      08038 (address)
3. Name, address and identification of nuclear power plant Salem Nuclear Generatin:J station Unit- #1 Foot of a1ttonwrxxi Road" Hancocks Bridqe. NJ 08038
4. System steam Generator Blc:Jlt.1rlam Nuclear Class II
5. a: Component repaired, modified or replaced 11GB3 Valve & Associated S\.gx>:rts b: Nameofmanufacrurer _ __.........

c: Identifying nos. See llttachrrent LCU..._------------------------------------

                                                           .......s;a...______

(mfr's. serial no.) (Narl.Bd.No.) Qurisdictional no.) (other) (year built) d: Construction Code See l>.ttadnrents (edition) (addenda) (Code Case(s)) (Code Class)

6. Section XI 1983 Sumrer 83 N/A (edition) (addenda) (Code Case(s))
7. Applicable edition of ASME Code Section XI under which repairs. modifications, or replacements were made: 1983 S83 N~/......A~--

(edition) (addenda) (Code Case(s))

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *See Attachments 72 (edition) (addenda) (Code Case(s))
9. Design responsibilities ....s:.:w.&lloa..__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
10. Tests conducted: hydrostatic Ii pneumatic D design pressure O** pressure 1400 psi Code Case(s)_""N'"'"--4"'"'1=6.-......._ _ _ __
11. Description of work Replaced valve with new design arxl npclified associated sug:x>rts.

(use of addillonal sheet(s) or sketch( es) 1s acceptable if properly identified) -~~~~~~~~~- CERTIACATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edtion. Certificate of Authorization no.

  • 36 to use the "NR" stamp expires Oct. 3, , 19 94 care ef-z-1 19~ s~""' PSE&G CO.-Nuclear Dept. ~ Principal En;Jr (repair organization) (au z re resentamre) (title)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors. and certificate of competency issued by

 .the state or province of           New Jersey and employed by                                       Arkwri t Mutual Insurance Co of         MA            have inspected the repair, modification or replacement described in this report on                                J'~ I           , 19           and state that to the best of my knowledge and belief. this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
                                                                                                                                              ' F.9,ctory Mutual System te    ~-")I/        ,19 /jJ,, . Signed                             f: ~                                       Commissions        /1/J J 7}
  • I (Inspector) (Natl.Bd.No.(including endorsements)state or province and number)

This form may be obtained from The Natlonal Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB-81 Rev.6

Page _L_ of _2_ FORM NR-1 ATl'ACHMENT Code Job Package No.: P92-010

e. 3.

Work performed by: owner: Location: Public Service Electric & Gas co., Nuclear Dept. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 Public Service Electric & Gas co. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 Salem Nuclear Generating Station Foot of Buttonwood Road, Hancocks Bridge, NJ 08038

4. System: Steam Generator Blowdown Nuclear Class: -'""""-----

II

  =================================~============================================

ID of Component Replaced: _,_l=l~G=B~3----------------------- Name of Manufacturer: _,_V~e=l~a=n*~-------------_;_---------~ 0416 NIA NIA NIA 1973 ~Y_e~s~-____,~---,..--~...,,..- Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Original Const. Code: ASME Sec. 3 1971 Edition W71 Addenda, Code Class ~ Code Cases: NIA ANSI B31.7 1969 Ed. 1970 Add. ID of Replacement: -l~l~G~B~3--------------------------- Name of Manufacturer: Edwards Cl 911 FJOT Y- XW - 7_NL.A_ .~~~~------------------------ NIA NIA 99=1::.__..,_ Yes

                                                                    =1......

Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: ASME Sec.III 1971 Edition H1.l_ Addenda, Code Class 2._ Code Cases:NIA ANSI B31.7 1969 Ed. 1970 Add.

  ==============================================================================

ID of Component Replaced: Name of Manufacturer: ~ Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? ~i~i~a~ const. 0 Code: Edition Addenda, Code Class Code Cases: - - - ID of Modified: 1c~BDS-34

                           -=----~-=--=-...__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ___

Name of Manufacturer: -=-P=S=E=&~G*~-----------------------~ NIA NIA ~N~IA~*---- NIA NIA =N=o---~~------- Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: ANSI BJl.1 1967 Edition 1970 Addenda, Code Class 2._ Code Cases:NIA ~AN==S=I~B=3=1~*~7--=1=9~6~9'-----

 ==============================================================================

ID ;of Component Replaced: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code stamp'd.? Original Const. Code: Edition Addenda, Code Class Code Cases: ID of Modified: lC-BDG-124 Support Name of Manufacturer: PSE&G

                                --=-==~~-------------------------~

N/A NIA N/A N/A 1992 =N=o---~-------- Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: ANSI B31.1 1967 Edition 1970 Addenda, Code Class 2._ llli/i;fe Cases:NIA ANSI B31. 7 1969 i ~================================~======================================~===

Page _L of *_J_ FORM NR-1 A'rl'ACHMENT Code Job Package No.: P92-010 ' 2. 3. Work performed by: owner: Location: Public Service Electric & Gas Co., Nuclear Dept. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 Public Service Electric & Gas Co. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 Salem Nuclear Generating Station Foot of Buttonwood Road, Hancocks Bridge, NJ 08038

4. System: Steam Generator Slowdown Nuclear Class:

2

   ==============================================================================

ID of Component Replaced: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Original Const. Code: Edition Addenda, Code Class Code Cases: - - - ID Of Modified: _,::l=C~-=B=D=S_-=3=5-=S~U~P-P=O=r~t=----------------------------~ Name of Manufacturer: PSE&G

                             .-=-=~-=---------------------------------

N/A NIA _N_l_A~-- N/A 1992 ~N~o._______..,..._----~- Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: ANSI B31.1 1967 Edition 1970 Addenda, Code ClaSiS L Code Cases:N/A ~A=N=S~I~B=3~1~*~7--1=9=-=6=~------ - - - - - - - - -

   ==============================================================================

ID of Component Replaced:

~ame     of Manufacturer:
~                Nat'l. Bd. Jurist No.           Other        Year Built       ASME Code Stamp'd.?

Original Const. Code: Edition Addenda, Code Class Code Cases: ID of Replacement: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: Edition Addenda, Code* Class Code Cases:

   ==============================================================================

ID' of Component Replaced: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Original Const. Code: Edition Addenda, Code Class Code Cases: ID of Replacement: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.?

  • Replacement Const. Code: Edition Addenda, Code Class __

de Cases: 41 .

      =================================~======================================~===

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION fi9.0R INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of 2

1. Work performed by pnbl j c Servi re Electric & r..as Co. - Nuclear Dept. CJP #P92-0ll (name) (repair organization's P.O. no., job. no.,etc.)
  • Foot of J\lttorwyrl Road,. Hancocks Bridge. NJ 08038 (address)

(name) Foot of B.rttonwood Roa.d, Hancocks Bridge. NJ 08038 (address)

3. Name, address and identification of nuclear power plant Sa.lem Nuclear Genera.ti.rs station Unit #1 Foot of &rt:tonwrxxl Boad. Hancocks Bridge, NJ 08038
4. System steam Gene.rater BlO!rrlown Nuclear Class II
5. a: Component repaired, modified or replaced _,l.,2..,GB3,,...~V.~al:.......,v'""e,,______________________________

b: Nameof manufacrurer _ ___.iw..c:...LCl.u....._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ c: Identifying nos. See Attachrren..,t...s"------- (mfr's. serial no.) (Narl.Bd.No.) Qurisdictional no.) (other) (year built) d: Construction Code See Attacbm:rnts (edition) (addenda) (Code Case(s)) (Code Class)

6. Section XI J983 _ ...3..___ _ _ _ _ _ _ __

___..Si"'""-unrreULU<-..r~S N/A (edition) (addenda) (Code Case(s))

7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 N"""'/'"""A"'----

(edition) (addenda) (Code Case(s);

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *See Attachments 72 (edition) (addenda) (Code Case(s);
9. Design responsibilities J:w.l:dl!!J.__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
10. Tests conducted: hydrostatic IX pneumatic D design pressure O**pressure 1400 psi Code Case(s)_~N~--4~1_6_ _ _ __
11. Description of work Replaced valve with valve of new design.

(use of additional sheet(s) or sketch(es) is acceptable if properly identified) 12.Rem~~: -~Wo-..iJr~k~oni,l.l,l..~e~r~#~*---..::9~J~1~auJ~5~2~1~2---------~~c..Lf~ic'-i.l.lie~~~l'--'B~e~pi.Aol.Lrrt..J.._~#~:_.u~~/~A._________ D?sign OJarge Package #: lEC-3133 Pkg. 1 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National BoMd rules as defined in the publication NB-102, current edition. Certificate of Authorization no.

  • 36 to use the "NR" stamp expires Oct. 3, , 19 94 9

Date ,, -  ::i_s- PSE&G eo.-Nuclear Dept. 19.--1...b.. Signed._ _ _ _ _ _ _ _ _ _ _ _ __ Principal Ergr (repair organization) (authorized representative) (title) CERTIFICATE OF INSPECTION _I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwright Mutual Insurance Co of MA have inspected the repair, modification or replacement described in this report on F 2I . 19 7 2..-../ and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Bo~ rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthennore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Factory Mutual System

                                                    ~/ ~ ~

I

       * 'i-J-) . 19 fl.-:              s;g,ed                                                                             Commissions     .<J::J3 7 3                                        I (Inspector)              .                                   (Natl.Bd.No.(induding endorsements)state 0< province and number)

Thia form may be obtained from The-Natlon_al Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229 *

                .*                                                                                                                                                                                 NB.al Rev.6

Page ~ of .2_ FORM NR-1 ATTACHMENT Code Job Package No.: P92-0ll Work performed by: Public Service Electric & Gas co., Nuclear Dept. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038

2. Owner: Public Service Electric & Gas Co~

Foot of Buttonwood Road, Hancocks Bridge, NJ 08038

3. Location: Salem Nuclear Generating Station Foot of Buttonwood Road, Hancocks Bridge, NJ 08038
4. System: Steam Generator Blowdown Nuclear Class: --=I=I~---
  ==============================================================================

ID of Component Replaced: --=1=2~G=B=3----'V~a=l~v~e.,_~--~-----~-----~-- Name of Manufacturer: --'"V~e=l=a=n=----~--~--~------_:_~--~--~--~ 0421 N/A N/A N/A 1973 =Y=e=s~-------~ Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Original Const. Code: ASME Sec.III 1971 Edition W71 Addenda, Code Class 2.___ Code Cases:_N/A ANSI B31.7 1969 Ed. 1970 Add. ID of Replacement: --=1~2~G~B~3'---V~a=l~v~e=--------------------~-- Name of Manufacturer: --=E=d~w=a=r~d=s"'--~--~--~--~----~~-~---~ C1911FJOTY-XW13 N/A N/A N/A ~1-99_1=-_,,,~ Yes Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const~ Code: ASME Sec.III 1971 Edition W71 Addenda, Code Class 2._ Code Cases:N/A ANSI B31.7 1969 Ed. 1970 A~

  ==============================================================================

ID of Component Replaced: ame of Manufacturer: ~--~-----~--~--~--~--~--~--~ Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Original Const. Code: Edition Addenda, Code Class Code Cases: ID of Replacement: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: Edition Addenda, Code Class Code Cases: - - - - - ' -

  ==============================================================================

ID of Component Replaced: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Original Const. code: Edition Addenda, Code Class Code cases: ID of Replacement: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? placement Const. Code: Edition Addenda, Code Class _ de cases: - - -

- ==============================================================================

FORM NR*1 REPORT OF REPAIR 0 MODIFICATION~ OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of 2

1. Work performed by public Service Electric & r..;:i5 CO. - Nuclear r:iem:. CJP #P92-012 (name) (repair organizauon's P.0. no., job. no.,erc.)
  • Foot of axttonwood Road, Hancocks Bridge. NJ 08038 (address)

(name)

           *Foot of Buttonwood                                      Road,              Hancocks                  Bridge,          NJ      08038 (address)
3. Name, address and identification of nuclear power plant - Salem Nuclear Generatirg Station Unit #1 Foot of arttonwpcrl Road., Hancocks Bridge, NJ 08038
4. System steam Generator Blc:JWdc;7<<n Nuclear Class II
5. a: Component repaired, modified or replaced 13GB3 Valve & Associated SUpports b: Nameofmanufacrurer _ _..J!.IO;.,i.s;;&U.._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

c: Identifying nos. 5ee Attachment (mfr's. serial no.) (Narl.Bd.No.) uurisdictional no.) (other) (year built) d: Construction Code See Attachments - - - - - - - - - {edition) (addenda) (Code Case{s)) (Code Class)

6. Section XI 1983 Surmrer 83 N/A (edition) (addenda) (Code Case(s))
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 583 -=-N"""/A=---

{edition) (addenda) (Code Case(s))

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *See Attachment 72

{edition) (addenda) (Code Case{s))

9. Design responsibilities ~PS~E~&G=---------------------------------------
10. Tests conducted: hydrostatic [)c pneumatic D design pressure D **Pressure 1400psi Code Case(s) _ _ N_-_4~1~6_ _ _ __
11. Description of work Replaced valve with valve of re<< design an::i nn:lified associated (use of additional sheel{s) or sketch(es) is acceptable if properly identified)
12. Remarks: _._..llWon.lLr...l!k~OrTI.u...i.a:e::..ir--.;#'--':.__;:9z.<lw1~0LJ1'-5...,2;...3L::9z....__ _ _ _ _ _ _ _~Da.s::w.f..1i.i.c...ii.s:er.1C¥;,i,.~~Re~Poo!IJ,l,rt.....__..:ii#c..o:~~"'/..cAL.-_ _ _ _ _ __

D?sign Olarge Package #: lEC-3133 Pkg. 1 See attached pages for Description of Replacernent0 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition.

 """'.'d:c""°"'"'o" ,o, * .                                          36               to use the "NR' stamp expires                         oct.      3, , 19 Date Ch/

19,~. Signed PSE&G Co.-Nuclear Dept

                                                                                                                                      '         --~~~;;::z!~;::::___

Principal Ergr (repair organization) (title) CERTIFICATE OF INSPECTION

    --~--- have inspected the repair, modification or replacement described in this report on                                                                                                                and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
                                                                                                              .          .                                              ~ctocy                Mutual System /

f . . 2{ ,199],,.Signed~{~ Commissions ,J.J,JJl / {Inspector) . (Nad.Bd.No.{induding endorsements)state or province and number) Thia form may be obtained from The Natlona_I Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB-ii Fl8'* 6

Page J _ of J _ FORM NR-1 ATTACHMENT Code Job Package No.: P92-012

    • 2.

3. Work performed by: Owner: Location: Public Service Electric & Gas Co., Nuclear Dept. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 Public Service Electric & Gas Co. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 Salem Nuclear Generating Station Foot of Buttonwood Road, Hancocks Bridge, NJ 08038

4. System: steam Generator Slowdown Nuclear Class: ___2______
 ==============================================================================

ID of Component Replaced: -=1~3~G~B~3~V~a~l~v~e=------------------- Name of Manufacturer: __.;..V~e=l=a=n=-------------------------- 0432 N/A N/A N/A 1973 ~Y_e_s_________.......,...._ Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? original Const. Code: ASME Sec.III 1971 Edition li2l. Addenda, Code Class ~ Code Cases: N/A ANSI B31.7 1969 Ed. 1970 Add.-- ID of Replacement: -=1_3~G_B~3~V~a~l~v~e=----------------------- Name of Manufacturer: Edwards

                                -='-=-"'-=-='-="~------------------------

C191 l FJ QTY - XW 14 N/A N/A N/A =1~9~9=1~*----- ~Y=e~s~---------------- Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: ASME Sec.III 1971 Edition W71 Addenda, Code Class z_ Code Cases:N/A ANSI B31.7 1969 Ed. 1970 A~--------------------

 ==============================================================================

ID of Component Replaced: ~ame of Manufacturer: ~ Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Original Const. Code: Edition Addenda, Code Class Code Cases: ID of Modified: ~l~C_-=B=D~G_-_1~2_3~S~u_p_p~o_r~t~----------------------------------- Name of Manufacturer: ~P=S=E=&=G0 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ ; _ N/A N/A ~N_/~A..,....._____ N/A 1982 ~N~o~------------------ Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: ANSI B31.7 1969 Edition 1970 Addenda, Code Class z_ Code Cases:N/A AN=.=...=S=I-=B~3=1~*=1-=19~6~7...._,E~d~*~/~A=~~M=E=--S~e=c--.....*~I=I=I=--N~F--..-1=9~8~3~S~8~4"'-'N~C=I=-~

 ==============================================================================

ID of Component Replaced: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Original Const. Code: Edition Addenda, Code Class Code Cases: ID of Modified: -=l~C~-~B=D=A~-~4~3~S~U~P~P~o=r~t-...._______~------------~------~------ Name of Manufacturer: PSE&G

                                ----~~---~-----,.-------~--~------~--

N/A N/A N/A N/A 1992 ~N~o~--------..,-------_,,.- Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: ANSI B31.7 1969 Edition 1970 Addenda, Code Class z_ ode Cases:N/A ANSI B31.1 1967/ASME Sec. III NF 1983 584 NCI /

  • -=============================================================================

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION~ OR INSTALLATION OF REPLACEMENT(S) D TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 2

       , . Work performed by          p1bl i c Send re Electric & r..as ea                                    -      N11c1 ear                       D?pt.                            C1P #P92-013
               .                                                                                    (name)                                                             (repair organiza11on*s P.O. no., job. no.,etc.)
  • Foot of p;ntt01"!Se1QC"rl Road, Hancxx:ks Bridge, NJ 08038 (address)

(name) Foot of art;torn.ryXJ Road, Hancocks Bridge, NJ 08038 (address)

3. Name, address and identili6ation of nuclear power plant _ _......,Sri,,.al.,....,em.....__.Nu,_,,.,c,..l...,e.,,;:i..,r.._,,,,Genera,,.,,._..,,,,,==t~l.@=*

L!;ll__,,,S,_,,ta~t~i"'!'a::!Jn!..!.,__Uni~~*~t=-.J#i.:1~----- Faot of S1ttonwpcrl Rood. Hancxx:ks Bridge, NJ 08038

4. System steam r....::merator Bl Maro Nuclear Class II 5.a: Componentrapa~ed.mooffied~ra~~~l~4~G~R~3~--¥~a~J~v~~~~-------------------------

b: Nameofmanufacrurer --..v.c~u...----------------------------------- c: Identifying nos. *See Attachrrent (mfr's. serial no.) (Narl.Bd.No.) Ourisdictional no.) (other) (year built) d: Construction Code See Attadvrent (edition) (addenda) (Code Ca!?e(S)) (Code Class)

6. Section XI 1983 N/A.

(edition) (addenda) (Code Case(s))

7. Applicable edition of ASME Cooe Section XI under which repairs, mooifications, or replacements were made: 1983 S83 -=-N.,_/=A_ _

(edition) (addenda) (Code Case(s))

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *See Attadl!rent 72 (edition) (addenda) (Code Case(s))
9. Design responsibilities ...............,,.....~--------------------------------------
10. Tests conducted: hydrostatic [k pneumatic D design pressure D **Pressure J400psi Cooe Case(s)_~N~--4~1_6~----
11. Description of work RepJ aced valve with valve of new desi90.

(use of addillonal sheet(s) or sketch( es) is acceptable if properly identified) 12.RemM~* _ _..w~o~rkA~OUl ......~e~r~#~'---:9~1~1~o~J~s~2-4~3---~~----~Do"""""f~i~c~i~ency .......i'-'RwP~p=>fo&-&'rt~~#~*...........~~/~A,.__~-~-- resign Cllange Package #: JEC-3133 Pkg. 1 NOP see attached pages for D=scription of Replacerrent. CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, mooification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication N8-102, current edition. Certificate of Authorization no.

  • 36 to use the 'NR' stamp expires Oct. 3, . 19 94 Date : Cff*l A, /',.. PSE&G eo.-Nuclear D:pt.

19.~. Signed _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

                                                                                                                                              ~                                                        Principal           En3r (repair organization)                                                  ~                                                                 (DDe)

CERTIFICATE OF INSPECTION

      --=-==---- have inspected the repair, modification or replacement described in this report on                                                                                     , 19£V         and state tt:iat to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME COO& and the National BoMd rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any wMranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

te '1~.Z'/ *1siL_. Signedr?, £~* Commissions p./jfJ'ry Mutual system/

                                                        ~               (Inspector)                                                          (Nad.Bd.No.(induding endorsements)state or province and number)

Thia form may be obtained from The Natlonal Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB*B' Rev.6

Page _L of _L FORM NR-1 ATTACHMENT Code Job Package No.: P92-0l3

  • 2.

3. Work performed by: owner: Location: Public Service Electric & Gas Co., Nuclear Dept. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 Public Service Electric & Gas Co. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 Salem Nuclear Generating Station Foot of Buttonwood Road, Hancocks Bridge, NJ 08038

4. System: Steam Generator Blowdown Nuclear Class: 2 ~~---
  ==============================================================================

ID of Component Replaced: -=1~4~G=B~3__.V~a=l~v~e--~~~~~~~~~~~~~~~~~- Name of Manufacturer: _,.V~e=l~a=n.:__~~~--~~~~------~--,-~~~------ 0438 N/A N/A N/A 1973 Yes Serial No. Nat'l. Bd. Jurist No. Other Year Built ASM_E_C_o_d_e~S-t_a_m_p_'d-.-?- Original Const. Code: ASME Sec. III 1971Edition W71 Addenda, Code Class £____ Code Cases:_N/A ANSI B31.7 1969 Ed. 1970 Add. ID of Replacement~ =1~4~G=B~3'--V~a=l~v~e""---~-~------~-~~~-~-~~~ Name of Manufacturer: ---~~~---~-~~~----~~-~~~~~-~-~- Edwards Cl 911 FJ QTY - XW - 8 NIA N/A N/A =1~9~9~1~-- Yes

  • Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.?

Replacement Const. Code: ASME Sec. III 1971Edition H11._ Addenda, Code Class ~ Code Cases:N/A ANSI B31.7 1969 Ed. 1970 Add.

  ==============================================================================

ID of Component Replaced: me of Manufacturer: erial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Original Const. Code: Edition Addenda, Code Class Code cases: - - - ID of Replacement: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Other Year. Built ASME Code Stamp'd.? Replacement Const. Code: Edition Addenda, Code Class Code Cases: - - -

  ==============================================================================

ID of Component Replaced: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Original Const. bode: Edition Addenda, Code Class Code Cases: - - - ID of Replacement: Name of Manufacturer:

. Serial No. Nat'l. Bd. Jurist No.           Other   Year Built    ASME Code Stamp'd.?

Replacement Const. Code: Edition Addenda, Code Class . d e Cases: . . ,.

  ==============================================================================

FORM NR*1 REPORT OF REPAIR C MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S)~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

1. Work performed byJ?11hl ic Se.rvia:> Electric & C..as Co , Nlx:lear l'Ppt., Crxie Job ~- #591--074 (l\lltnel (repair or;anlllho;;:;~O. no .. Jot> no .. *IC.I Foot of Bnttorwxxl Road, HalXXX:-ks Bri~, :til 08038
  • faddress1
2. Owner Puhl ic service Electric aoo r..as Cl:>. - Nuclear D?pt.

1name1 Foot of QrttorwxxJ Raad, HaJX"l"dra Bri&Je, NT 08038

                                                                                             "(address1
3. Name. address and identification of nuclear power plant Salem C..eneratir~ station Unit #1 F'cx)t of a1ttonwrcd Raad; Hancxx:ks Bri<i)e, NT 08038
4. Identification of system Safecy Inject-ion - Nuclear Class I
5. a: Identification of component repaired, modified or replaced l.C=CVC-SN901 - snuti:ler b: Name of manufacturer Pacific SCientific catpaDy c: Identifying nos. 321 N/A N/A N/A ~1~9~7~4~----

1n-** s serial no.I (Nal"J. Bd. no.I (junsd1cuonal no.) (other) (y- built)

6. Applicable section(s) XI of ASME Code, 19-8.l._ edition 8'JIJ!rer addenda 1983 Code Case_,,_N.,../-=-A=----
7. Design responsibilities _ _ _.._PSE"""".,,,.&G~-------------------------------
8. Tests conducted: hydrostatic - pneumatic = design pressure = pressure psi. N/A
9. Description of work Rsplace::i snnhhRr SIN 321 with SIN 26130.

(use of ad<l11oona1 sheet(SI or Sketch(es1 is acceptable ii properly *dentlfie!I) Original Construction rme Frljtion N/A N/A N/A Work Onier #901119016 Deficiency Report # N/A Mfr's serial No. Nat'l Ed. No. Jurisdictional No. other vear Bpjlt (Yes/NO) 26130 N/A N/A N/A 1987 y Replacen-ent Construction cme Edition A5ME Sec. I I I 1974 SUrrgrer 1976 1644-4 CERTIRCATE OF COIFUANCE We certify that the statements made in this report are correct and that all design, material and workmanship on this*~ conforms to the applicable section of the ASME Code. '

  • ar riPliiiiiiitiii Certifk:ate of Authorization no. 36 to use the "N
  • Oct. 3. 19 94 ~

s*igned PSE&G Co.-Nuclear Dept. Manager-Station ~ /{Is;"' 19 '// (rapai-

  • amn1 (tit>>) '

CERTIACATE OF INSPECTION I, the undersigned holding a valid commission issued by The National Board of BoUer and Pressure V~ssel lnspec:tors, and certifcate of com* petency issued by the state or province of New Jersey and employed by Arkwright M.rt:ual. Insurance Co _ _ _ _ _ _ _.,....,._ _ _ _ _ _ of No:rwood,MA have inspected the repair, modification or replacement described in this report on lb-} D 19 Ci { and state that to the best of my knowledge and ~ief. this repair, modification or replacement has been made or

  • constructed in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB 102 current edition.

signing this certificate, neither the inspedor nor his employer makes any warranty, expressed or implied, concerning the repair, modificat~n placement described in this report. Furthermore, neither the inspector nor his employer shall be liabie in any manner for any personal injury property damage or loss of any kin ising from or nnpctep with_ this inspection. 1"a?U~ Mutual system Date 11- t~ 191!.._Signed * ~ Authorizad inspei::tlll) Commissions---:!M~--~1~'1--:-::--.,.-___,.--...,.......--,-~...,-- Na . no. (ilctidl'l) ~II) ltlll* ar p!"OWa and rurm.r) This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229

               .  .
  • NB~1 Rev. 5

FORM NR-1 REPORT OF REPAIR O MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) '.X TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

1. Work performed b!>IJblic Service Electric & Gas ....Cb-...,,,.........Ni-ic-J...ea.....,....

r__._rept"""t' Job

                                                                                                                                          .......,,,__.Ccrle-.-..................'--"'~~a~....;#i:.;.S""'9._Ji..:-O::;.J,L.7....s...___

(name) (repair or;an1zat1;;n:;i1.o no .. 1ob no .. etc.I Foot of 9.Jt'tonwood Road, HaJXXlCks Bridge, NJ 0803a (address1

2. Owner Ftlblic Service Electric am r... s Co - N11cl ear ~.

(name) Foot of Buttorwxrl Road, Harcrr:ks Bridge, NJ 08038 (address1

3. Name. address and identification of nuclear power plant Sal em C..eneratirg station Unit j1 Foot of Buttorwxrl Road, Harcrr:ks Bridge, NT 08038
4. Identification of system safety Injec+/-im - Nuclear Class I
5. a: Identification of component repaired, modified or replaced 1S-14FW-SN013B Sn11bher b: Name of manufacturer Paci fjc Scientific c: Identifying nos. 476 1mlr s serial no.I NIA (N:i:1 Bd. no.) (jurosdicuona1 no.1 N/A (Other) 1976 (year built)
6. Applicable section(s) XI of ASME Code. 19.8.3.._ edition SUmmer addend_al....,9=8....,3.....__ _ Code CasEN A.___ __
                                                                                                                                                                                                           .....,./.....
7. Design responsibilities _ _......J?SE ...........&G......__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
a. Tests conducted: hydrostatic pneumatic = design pressure '= pressure p!tl/A
9. Description of work Repl aa:rl snuttier SIN 476 with SIN 30359.
                                                                         '(Us; of additional sheet(si'or sketch(es) is acceptable if properly identified)

Original Constnx+/-j m Crrle F.c:litjon Code cases ASME Sec. ITT 1974 Winter 1975 1644-4

10. RJmutcs:

C,.l.J wark Order #901119016 Deficiency Report # N/A Mfr's Serial No Jurj sdj ct j anal No. Year 'flliil t (Yes,INo) 30359 N/A N/A NIA 1986 y Replacerrent Coru:;tnx+/-jon cme FrHtion ASME sec TIT 1980 Winter 1982 N71(1644-6), N-247 CERTIACATE OF INSPECTION I, the undersigned holding a valid commi8sion issued by The National Board of Boner and Pressure V,essel Inspectors, and certificate of com-petency issued by the state or province of New Jersey and employed ~kwright MUtual Insurance Co

  --....,,....-..,,,....,..--~.-r-------of Nonvood' MA have inspected the repair, modification or replacement described in this report on f       ,,z3     19   '1J      and state that to the best of my knowledge and belief, this repair, modification or replacement has been made or
  • constructed in accordance with Secti>n XI of the ASME Code and the National Board rules as defined in the publication NB 102 current edition.

signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the repair, moctrication placement described in this report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal inj4~ property damage or loss of any

  • Date //-/'/ 19~ I Signed ising from n ected with this inspection.
                                                                                                 .        Commissions---::IJ~~J~
                                                                                                                                         ~<;t:.o]      =Mutual J"'"-='ZJ_""--:--~------.,---.-

System

                                                                                                                                         ,_, Bet no. (ilc::lidng endorlements) Illa* Of pteVince and 111n1>9r)

This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 NB-81 Rev. 5

FORM NR*1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S)U TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

1. Work performed by p11hl ic Service Electric & C..as D:l., Ntx:le.ar D?pt., Crrle Job~- #591-076 1name1 (repair organ1uu1on*~ no.. 100 no .. etc.I Foat of Bnttorwxxi Road, HaDQ?Cks Rri":Je, NT 08038 iaddreul
2. Owner J?!1hl ic ServiO? Electric aOO C..as Co - Nuclear D:>pt.

1name1 Foat of Bl :rttnrwxrl Raad, Hancxx:ks Bri d:Je, NT 08038 1address1

3. Name. address and identification of nuclear power plant 5alem GeneratiIVJ station Unit u Foot of art:tons.rxxl Road, Harxxx:ks Bdci;eu NJ 08038
4. Identification of system Safety Injection - Nuclear Class I
5. a: Identification of component repaired, modified or replaced 1S-13FW-SN015B Srn1tpar b: Name of manufacturer Pacific Scientific c: Identifying nos. 389 N/A N/A N/A<otner) 1974 1mtr. s serial no.) (Nan Bd. no.1 Uunsdlciional no.) (year built)
6. Applicable section(s) XI of ASME Code, 19--81 edition SllDJDer addenda 1983 Code Case._....,~.,._/..._.A...___ _
7. Design responsibilities _ _ _.....PSE&G'""""""""""--------------------------------
8. Tests conducted: hydrostatic = pneumatic =::: design pressure = pressure psi. N/A
9. Description of work Replaced snubber SIN 389 with SIN
  • 26131.

(use of acld1t1ona1 sheet(S) or ske1ch(es) is acceptable ii properly iden!llied) Original Construction Code Edition COcie c=ises N/A N/A N/A N/A

10. {!~s:

Work Onjer #901119016 Deficiency Report # WA Mfr's Serial No. Nat' 1 &i. No. Jurisdictional No. other Y@r Built (Yes/NO) 26131 N/A N/A N/A 1987 y Replacement Construction Code F'rlition Adderrla ASHE Sec. I I I 1974 SUmaer 1976 1644-4 CERTlACATE OF COMPLIANCE We certify that the statements made in this report are correct and that all design, material and workmanship on this _.,Re._n...,1.aceme _ _.-.rri...,t_ _~

                                                                                                                                                        .(lepiii: rnxiiGOl1 <illPiaamerit) conforms to the applic;i...ble section of the ASME Code.

Certificate of Authorization no. 36 to use th

  • Qct. 3. 19 94 Signed PSE&G Co. -~11ear Dept. Manager-station ~

(repair --* (1i119) CERTlACATE OF INSPECTION I, the undersigned holding a valid commission issued by The National Board of Boiler and Pressure Ve~el lnspectors,_and certificate of com-petency issued by the state or province of New Je:rsej and employed by Arkwright Mutual Insurance Co

 --~---=---r-t------- of Norwood, ~ave inspected the repair, modification or replacement described in this report on l - L)             191/         and state that to the best of my knowledge and belief, this repair, modification or replacement has been made or constructed in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB 102 current edition.

signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification eplacement described in this report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury r property damage or loss of any ki 'sing fro or co with this inspection. FactoIT Mutual System Date /I-It/ 19t:fl Signed Commissions...;..~~'.'I:~J~?~J~=----,--------- Nai Bet no. (lndudng endorseman111) llate or ptOlinai and run1>er) This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 NB.al Rev. S

FORM NR-1 REPORT OF REPAIR= MODIFICATION~ OR INSTALLATION OF REPLACEMENT(S) CX TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS i Wortr. pertorn-ed by Public Service Electric & Gas Company - Nuclear Dept. CJP f*S-91-084 rreoa1t o*Qaniza11on 9 P O. no .. 101> no .. e1c.1 Foot of Buttonwood Road, Hancocks Bridge, NJ 08038

                                                                                         ~acoresst 2 owner ~--P_u_b_l_i_*c__        s_e_r_v_i_c_e_E_l_e_c_t_r_i_c_&_G_a_s_C_o_m~p~a~n~y:---------~-~------------

1name1 Foot of Buttonwood Road, Hancocks Bridqe, NJ 08038 1aaaress1

3. Name. aoaress and identification of nuclear power plant Salem Nuclear Generating Station Unit t 1 Poot of Buttonwood Road, Hancocks Bridge, NJ 08038 4 Identification 01 system _r_1_a_i_n_s_t_e_a_m__N_u_c_l_e_a_r_C_l_a_s_s=-_I_I-::--=-:---:---::----:-::-:---------------

S. a: 1oen11f1cat1on of component repaired. modified or rep1ace0_S_po_o_l_P_i_e_c_e_l_M_.s_-_4_0_7_3_B_ _ _ _ _ _ _ _ _ _ _ _ __ b: Name ot manufacturer N/A c: Identifying nos. ____ *N=/=A=======---.. 7 N:: */'ll-=----------,-N-/A:--------N... /_A______ l_9_6_9_ _ __ 1mtr s serial no 1 1Nan Bd. no; 11urisd1ct1ona1 no.1 i01"9r) (yur Du*lll

6. Applicable sect1on1s) XI ' of ASME Code. 19_ 8'3_ edition 1983 addenda Summer Code Case N416
7. Design res.,onsibilities PSE&G ---J------------
8. Tests cor-cucted: hydrostatic ~- Jneumat1c = design pressure .:: pressure 1420 psfSystem Inservice Test HOP 9 _ Descnptic- of work Replace spool piece elbow 1MS-4073B in kind. .

ruse of ~Od11tona1 sneet1s1 or SKefcn1es1 is accecnaDle 1f oroD@ny 1den11fleo1

10. Remartls:

Work Order #901130209 DR # S . M D - 9 1 - " 0 : - ; : 6 ' " " 3 - - - - - - - - - - - - - - - - - - - - - - - - - - - CERTIRCATE OF COMPLIANCE We eenify thar the statements made in this report are correct and that all design, material and workmanship on this Replacenen t (IDllU', iTIXiifiCiion Of '9Plal:imiil1J conforms to V"E applicable section of the ASME Code. Certificate of Authorization no. 36 . to use the "NR" stamp xpi s October 3 19 9_1_ __ Signed ?SE&G Nuclear Department _k. ..le4 Manager-Station QA

  • j/

19 (lllPU *IOll) ,,) {W~ed~1119) (lill9) CERTIRCATE OF INSPECTION I, the undersigned holding a valid commission is5ued bv The National Board of Boiler and Pressure,Y~~el Jnsoectors, andJ:ertificate of com* New- Jersey ArAwrignt'Mutua~-Ins. co. petency issued by the state or province of Norwood, MA and employed b ' f - - - - - - - - - - - - - - - -

                     .                                   of                          have inspected the repair, modification or replacement described in this report on       S°' k         1 gq/       and state that to the best of my knowledge and belief, this repair, modification or replacement has been made or constructed in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB 102 current edition.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification eplacemenl described in this repon. Furthermore, neither the inspector nor his employer shall be iable in any manner for any personal inj~ry P!rtY damage or loss of any ki~ing from or,9)'t::Lith this inspection. Facto,~ Mutual system

  • Date £-' igt:// S i g n e d _ l'.

Aulhor211d in5PQCIDll

  • Commissions_Al...__'$~]_7._'..)_ _ _ _ _ _ _ __

Na1 Bel. ra. (rlCilding enilorssnenll) 11a1e or pigwtnoe and nun1>er) This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 NB-61 Rev. !

FORM NR-1 REPORT OF REPAIR ~ MODIFICATION .....: OR INSTALLATION OF REPLACEMENT($) C TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

1. Work performed by0Jbl ic Send a ! Electric & C..as Ch. - Nuclear I);pt. CJP #S-91-122 1name1 1*e1H1" organ1za1ron 1 P.O. no., job no .* etc.I Foot of Bl Ittarwrd Ro3d, Harnx:ks Brj °=Je, KI 08038
                                                                                              !AddrHSI
2. Owner f'!K>l ic SeDrin=o Electric ard ("-as en - Nuclear J):!pt.

enamel Foot of BIItta"W"X'rl Road, J.Janax:ks Bridr;J?, NJ 08038 (Address1

3. Name. address and identification of nuclear power plant 5al em GeneratiDi1 station unit # 1 Foot of Blrtton.rrrl Road, Hanax:ks Bri c%Je u NJ 08038
4. ldentificatioo of system _ __.Ma._1..
  • n....__.st..._ea_m...__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
5. a: Identification of component repaired. modified or replaced 11 st-fflm Generator Seron:iaey Han:l Hole Flan;;ie b: Name of manufacturer _ _ ___._,Hest.iDiJbruse._~*---.-..-------------------------

c: Identifying nos._...,l_,..0,,.,03..______ 68-10 N/A N/A 1969 (mh:s serial no.) (Nat'I. Bel. no.) (Other) {year built)

6. Applicable section(s) XI of ASME Code, 19....8L. edition 1983 addenda SUnmer Code Case N/A
7. Design resoonsibilities _ ___..PSE&G..-..,._.,,.___ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
8. Tests concucted: hydrostatic - pneumatic = design pressure
9. Description of work _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
                                                                                                            =       pressure NOP              psi. system Inservice Test cuse of'add1t1ona1 sheetcsl or sketchces1 1s acceptable ii properly identified)

Repahw pitt~ on 11 steam generator secorrlacy han:i hole flarge by mac::hinim.

                                       \tl) #901120018 tB     #ISI-91-127 CERTIFICATE OF INSPECTION I, the undersigned holding a valid commission isSued by The National Board of Boiler and Pressure V9ssel Inspectors~ and certificate of com-petency issued by the state or province of                    New Jersey
  • and employed bot Arkwright M.Itua.l. Insurance Co
 - -.......-.,,......--~------of Norwood
  • MA have inspected the repair, modification or replacement described in this report on lf-1 ( 191// and state that to the best of my knowtedge and belief, this repair, modification or replacement has been made or constructed in a:cordance with Sectk>n XI of the ASME Code and the National Board rules as defined in the publicatbn NB 102 current edition.

By signing this cert!"icate, neither the inspector nor his employer makes any warranty, expressed or impl"led, conceming the repair, mOdl'ication acernenl described in this report. Furthermore, neither the inspector nor his employer shall be &able in any manner tor any personal injyry rty damage or loss of a~ny* ~or~ with this inspection. Fa~ Mutual System

              -         19q/       Sign      ~'-~                 AullortNd lrllpmcll2
  • Commissions-'M:~J:.~r-.

Nll1 Bd.

                                                                                                                                     ~...:,,71~3__,----..,...---,-....,....--~-

no.~ ~l 111.119 or pRMnc>> lllld l'llllN) This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave:, Columbus, OH 43229 NB~1 Rev. 5

FORM NR*1 REPORT OF REPAIR ~ MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

  • Page 1 of 1
1. Work performed by _..cl?!:i..1,.b...,J_,j....c.__..Se...,..nr._.._1_...'ce...,.._E l ..,ect......,,,.._r_.j.._c.._..&.___..Ga.....,s..__,,C..,,n......___-_...Nu......,c.,,.l,..ea!Oiliil.i.r_j,,,DeptSilo&.o*--~CJPl!.L.l'--l#~S~9~1&:-=l:!06~7.!..__ _ _ _ __

(name) (repair organization's P.O. no., job. no .* ete.)

         -~F~oot...tl.'J.....J.ouf._.ioaittoM.1-J,,,l,,,,IJnwrxxiwu
                                                             ................:R~~.._~,~Hancocksw.u.1~~LA.Br1.1...1.idg~eii<-t-.~NJ.%>L.._~0~8~0~32a_ _ _~--------------
                                                                                                                                                          'addressi (name)

Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 (address)

3. Name, address and identification of nuclear power plant Salem Nuclear Generating station Unit #1 Foot of Bnttonwo00 Rradg Ha.ncocks Bridge, NJ 08038
4. System Se?vice Water Nuclear Class II 5.a:~m~n~tre~~.moom~~re~~~~-~1--~~~---2~5~9~P~i~~=~~~=~l~----------------------

b: Name of manufacturer J?!1J J man Kell cqg c: Identifying nos. N/A (mfr's. serial no.) N/A (Narl.Bd.No.) (jurisdictional no.) NIA (other) NIA. 1972 (year bu ii t) d: Construction Code ANSI B31.1 1967 Btqition) ANSI '631 7 1969 1970 (addenda) N/A. (Code Case(s)) II (Code Class)

6. Section XI 1983 Summer 83 N/A (edition) (addenda) (Code Case(s))
7. Applicable edition of ASME Cooe Section XI under which repairs, mooifications, or replacements were made: 1983 S83 N=l:..:A=----

(edition) (addenda) (Code Case(s))

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *1969 1970 N/A
                                                                      .                            *ANSI B31.7/ANSI B31.1 1967                                                                       F.d.            (edition)                 (addenda)             (Code Case(s))
9. Design responsibilities _.c:w.i;:.m~---------------------------------------
10. Tests conducted: hydrostatic O pneumatic O design pressure O**pressure NOP psi Cooe Case(s)_~N_/~A~-----
11. Description of work Perfotined weld repair to pipe s,pool.

(use of additional sheet(s) or sketch(es) is acceptable if properly identified)

-~~~~~~~~~-
 . 12.Remarks: __Wunu~rAk__._.Orrl                .......~e~r~#~*..........;9L1~0~2~2~7.,_,_1~2~2_ _ _ _ _ _ _ _ ___.........................,~c.....o.;-t-..,,.,......_~#~:._.SMOo!LM.._,9~1.-_0~B,,,...,1'-----~

N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, mooification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as c;lefined in the publication NB-102, current edition. Certificate of Authorization no. 36 to use the "NA" stamp expires Oct. 3, , 19 94 PSE&G Co. -Nuclear [)ept. #; J _ -* Principal EnJr Date /()-s- 19,+/-L._. Signed. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -""'~""""" ..~e;a,,......::::"""""""":.:.*_ _ __ (repair organization) (authorized representative) (title) CERTIFICATE OF INSPECTION _I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwri t Mutual Insurance Co of MA have inspected the repair, modification or replacement described in this report on and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Cooe and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty,

  .expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector no~ his employer shall be liable in any manner for any personal injury or roperty damage or a loss of any kind arising from or connected with this inspection.
                                                                                                                          / ' .'                                                                                     Factory Mutual system t{". Lb~*                                                                Commissions                NJ3 *77                                                             *

(Inspector) (Natl.Bd.No.(induding endorsements)state or province and number) Thi* form may be obtained from The National Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB-81 Rev.6

FOAM NA-1 REPORT OF REPAIR C MODIFICATION ~ OR INSTALLATION OF AEPLACEMENT(S) ~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Dept. CJP jS-91-238 (repair organization's P.O. no .* 10C no.* etc.J

2. Owner Pt>hl ic senrjcp Electrjc am r..as Ch - Ntr:lear D=pt.

1namel Fky>t of BlrttawxXJ Rcwi, Hannx:ks Bridge, NJ 08038 (addreHI

3. Name, address and identification of nuclear power plant saJ en C-eneratin;J statj on IJnj t f l Foot: of Bnttcxwxrl Jirwi., Hanax:ks Bridge, NI 08038
4. Identification of system Majn steam - Nuclear CJ ass I I
5. a: Identification of component repaired, modified or replaced _ _.n,__,CME.U--'or.,__i_f_i,..ce--.....lS-...12A_...________________

b: Name of manufacturer -----A>,1~------------------------------- c: Identifying nos. N/A N/A N/A N/A 1mtr:s senal no.J (Nat'I. Bd. no.1 ounsdictional no.J (Other) ,,..., built)

6. Applicable section(s) XI of ASME Code, 19--.aJ... edition 1983 addenda Stl!Tl!'let" Code CaseN..._/_A_ __
7. Design responsibilities ---~PSE&G---...,.,~-------------------------------
8. Tests conducted: hydrostatic = pneumatic ::2 design pressure = pressure 770 psi. System Inservice Test
9. Description of work Replag:d boltiro' in orifice lS12A (use of additional shee11s1 or sKetch(eSI is acceptable ii properly identified!

Work Order #910415257

  • ~i:~i:t 1969 CERTIRCATE OF COMPLIANCE We certify that the statements made in this report are correct and that all design, aterial and workmanship on this ...,,~~~.~~...,,.cemen:>o<5iil0il....,.or ....~...,,~!'--m-._,,~,....

conforms to the applicable section of the ASME Code. Certificate of Authorization no. 36 to use the "NA Oct. 3, 19 94 Sinned PSE&G CO. -Nuclear Dept*

     ~                 (19PU      . milnl               ----:::Wh!W=rl~~==¥---

Manager-station <l' (11111) CERTIRCATE OF INSPECTION I, the undersigned holding a valid commission issued by The National Board of Boiler and Pressure Ve~el Inspectors, and certificate of com-petency issued by the state or province of New Jersey and employed by Arkwright 1'lrt:ual Insurance Co of No:rwoai,!!tiave inspected the repair, modification or replacement descri>ed in this report

  -on--S:--/i~,.....----19-q---7--and-stal--e-tha-tto the best of my knowledge and belief, this repair, modification or replacement has been made or
  • constructed in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB 102 current edition.

signing this certificate, neither the ilspec:tor nor his employer makes any warranty, expressed or implied, concerning the repair, modification acement described in this report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal iljuiy operty damage or loss of any ki 'sing from o co eel with this inspection. Factory M.rt:uaI system Oate /fJ 4-i 'f 19 I Sign Commissions~~~,.....1'--'?!--' 1 3=-,.--.,----~----

                                                                                                                       ~no. (\'lc:Wng ~l Ila* orproWa and IU1tler)

This form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229 NM1 Rev. 5

FORM NR-1 REPORT OF REPAIR C MODIFlCATION 0 OR INSTALLATION OF REPL.ACEMENT(S) & TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of l c.as_.,:::* Wor~  :::ieMor:"""leC by Public Service Electric & - Nuclear~* CJF ;s9l -256 Foo't of &Ittorrwocd Road, Han::ock.s Bridge, NJ 08038

aoc~oss.
 ~ :ow~e* ___Pub         __l_i_*c_Serv  ___ice          __El_ectr      ___ic_an:J             _ _Gas       __       eo 1name; Foot of 'B.lttonwood Road, Hanax:ks Bridge, NJ                                                                                08038 CA0:1rea1

_ Name adccess and identification ot nuclear power plan: Salem Nuclear Ge.nerat.in; station Unit #1 Foot of &IttoJ"l'W":lOO Road, Hanax:ks Bridge, NJ 08038

 .:   s~*sterr
  • O"le.mical Volune Control Nuclear Class 1
 ~ a Componen: *e:::ai:ea. modified or replaced                                     lC'V7 Valve
                                                                            --=--------~----------------------------~

Cl. Name o1 rr.an.;facturer~=-=-=-=-Cope-::--'::---:=-cVul~,,..---can---=-~---------=-=--=--------~=--------=-=~=------ c* identitying nos 691095001-58-3 N/A N/A N/A 1968

                                                                                                                                                                                                      -------~

(mt::s ,.,ia; no.I (Sal':. Bd. No.I ij~rtodictiona'. no.) (olher) :y...,, buih) d: Constructir.r :Oce ASME Draft Co:le for Pumps & Valves __l_9_68_Frl __._19_7_0_l;dd_ _* __ 1 ANSI ~ln, 7 1969 Frl. 19j1J;l~.  !(:odP~(S)) (Code Class) S Section XI 1983 SUmr!er 83 N/A (DdHion) (addenda) (Cooe C..S..(1)) 7 Appli-:able edition o~ ASME Code Section XI under which repairs. modifications. or replacements were made: 1983 S83 N/A (9dttion) (addendm) !Code C.-(sj1 S Applicable edition of Construction Code under which repairs, modifications. or_ replacements were made: _*__ 1968 1970 N/A PSE&G *~ ~~ tW9 fil.1;" W%15A&':7alves/ (Cod*) (DdHoonr (addendai ~Case(*)l 9 Design respor.sibilities _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _-:t~~lOC::IP!t-----I'eHp+/-'E!~r..;-:1~~i,,,.._',iAA.r-"'*~Otl.::iEAfltEeE~------ 10 Tests condu~ed hydros~a~~~e ~.fl'ij~ure 0 pressure _ _ _ _psi

11. Description o! work--------------------------------------------

Wor}{ 0Rler #: 910419133 Ecficiency Report #: N/A l 2. Remarks: ----1£es::e::;.:1~*gn:m--40=it:.3Ail:a:Ja:-~'t";j31ee-cfBl-'a<ckaffiii:i~g~e~#IH--:-:1~._.,l7H 1A'\--------::RHj(C~*'i--.,*.-.-:i~~l;n'A~--------------- See atr:.acl:ied pages foc D2ser'i~-Rt1:1tep~ln-:att0a3Cl~E!!A~tb.*.----N,~'}.A*----------

                              *Systae Insen*ire Pcrfoo:ed                                                       at    NOP CERTIACATE OF COMPLIANCE We cer1ity that the statements made in this repor1 are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, curren! edition.

Cer1ificate of Authorization no.

                                                    .            36                                        to uss the "NR" stamp expires OCt. 3'
                                                                                                                                                                              , 19 94 .

Date . *? - / i . 19,1..,,2,.. Signed FSE&G Co. -Nuclear Cept. L4- /.; 4 - Principal En¥* CERTIACAiE OF INSPECTION I, the undersigned, holding a valid 6ommi~i~yhe National Board of Boiler and ~A.-wri'ghti I~ qf-~f Dipetency issuedM!t( the stale or province of and employed by_ _ _ _ _ _*----,=-------...----------- of have inspected the repair, modification or replacement describe in this report on ~-*' , 19~nd state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, eltpressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from oim~~ ~s~ Date ~/) ,1etj].- Signed

                                                                  ~

f1.,,,.,.2e/ f~ 4~ (Au1horizltd lnspec10fj Commissions_N;-J=~_?_.1. 3~---------'- (NaJl.Bd.No.Qncluding endo<semenls)staJe or province and number) orm may be obtaine-d from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB-81 Rev.6

FORM NR-1 REPORT OF REPAIR= MODIFICATION= OR INSTALLATION OF REPLACEMENT(S) Ki TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

1. Work performed b.,p.Jblic SeJ:vice Electric & r...as Ca. , Nllcl ear D?pt. , Cqje Job P~. #591-265 1narne* crep*1r organ1z*t10;.~0. no .. JOI> no .* etc.1 Foot of Buttonwrxx3 Rrad, Hancxx:ks Bridge, NJ 08038
  • !address:
2. Owner P.>hlic Servia- Elec+/-ric ard C...as Co, - Ntx:lear IPpt.

(name, Foot of Birttoowncxl Ro3d, Hancxcks Bridge, NJ 08038 1aCJdress

3. Name. address and ident1ficat1on of nuclear power plant salem Generatirq Station Unit #1 Foot of Buttnrwxrl Brad, Harxxx:ks Bddge, NJ 08038
4. Identification of system Cbemical Volume Cbnt:rol - Nt>clear Class II
5. a: Identification of component repaired. modified or replaced 1CVE4 #11 Boric Acid Transfer Pl.mJp seal b: Name of manufacturer _ __,,Gou ........JITt>
                                                ...........1...ru_s....___.B      ........' - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

c: Identifying nos. N/A N/A N/A NjA _ _.1,..,,9"-"'7'--'0...__ __ 1mtr *s serial no 1 (Nafl.Bd. no 1 uur:s;;;ctional no.1 !other) (year built)

6. Applicable section(sl XI of ASME Code, 19....a.L edition summer addenda 1983 Code Case=N.._/=A,___ _
7. Design responsibilities --~PS....-E .....&G....__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
8. Tests conducted: hydrostatic = pneumatic = design pressure = pressure NOP psi. System Inservice Test
9. Description of work ~) ac;ed xrechanical purrp seal .

(use of add111ona1 sheel(sJ or s1<etch1es1 is acceptable ii orooerly 1dentilied) Orjgj nal Construction Code Fditicn Adderrla Cede cases Draft 'Amp & Valve o-rle 1968 N/A N/A Work Orrler #910612120 Deficiency Report # NIA ASME Code Stanped Mfr's Serial No. Nat'l Bd- No. Jurisdictional No. other YAAr &lilt* (Yes/Nol N/A N/A N/A N/A Repl aa:>rrent Constmc:ti on QPe Fditjon Addenda. Draft Bmp & Valve rme 1968 N/A N/A CERTIRCATE OF COMPLIANCE We certify that the statements made in this report are correct and that all des* ; material and workmanship on this ~~t i:~!iliiCririt) a>nforms to the applicable section of the ASME Code.

                                                                                                                                                                              -'.....,,.,~-=-3_,

Certificate of Authorization no. 36 to use the "N

  • Qct. 3. 19 ~9~4__

Signed PSE&G Co. -Nuclear Dept'-"---;;::;f;-;!~~~=--- (19Pair illlln) Manager-Station (lill8)

                                                                                                                                                                ~

(&Ii) 19 JL_ CERTIRCATE OF INSPECTION I, the undersigned holding a valid commission isSued by The National Board of Boiler and Pressure V~ssel lns~c:_>!.5~ and certificate of com* petency issued by the state or province of New Jersey and employed by Arkwright Mutua..i. Insurance Co

  - - - - - - - - - - - - - - - o f Norwood, MA have inspected the repair, modification or replacement desaibed in this report on       s-~         19C\f           and state that to the best of my knowledge and belief, this repair, modification or replacement has been made or
  • constructed in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB 102 current edition.

signing this certificate, neither the inspector nor his employer makes any warranty, express~ or implied, concerning the repair, modification acement described in this report. Furthermore, neither the inspector nor his employer shall be fiable in any manner for any personal injury operty damage or loss of any ki sing from or.conpectfd with this inspection. Factory Mutual System Date 11-13 19~Signed (. * ~ Au'lhorized inspeaOI) Commissions N*1 Bel. 11~ tJ:fno. $C\Sng , erdcn11TW111) llal* 0t plWinoe and rKJITblrl This form may be obtained from The National Board of Boiler and Pressure Vessel lnspedors, 1055 Crupper Ave., Columbus, OH 43229 NB-81 Rev. '

FORM NR-1 REPORT OF REPAIR. 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) ~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 Work performed by PUblic 5etvioe Electric & Gas Co. - Nuclear Dept. CJP #591-280

                                                                                                                                      ,,,.,,,.,                                                           (r-r 0tgaruzai_,'1 P. O. no.    ;oo. no.. elc.)

Foot of Buttonwood :Read, HaIXXlCks Bridge, NJ 08038 (addrna)

2. Owner _ _ _Pub __l_i_c_SerV __ ice__El_ectr __i_*c_arxi _ _Gas __ eo_.-----------,..-------------

(name) Foot of Buttonwood :Read, Harax::ks Bridge, NJ 08038 (add. . .)

3. Name. address and identification of nuclear power plant Salen Nuclear Generating statiai unit #1 Foot of Buttonwood :Read, HancoCkS Bri(lje, NJ 08038
4. System Chemical Volume CC11trol Nuclear Class II
5. a: Component repaired, modified or replaced #12 eve Boric Acid Transfer Pl.mp b: Name of manufacturer Gould PUnps c: Identifying nos. 70439361 N/A N/A N/A 1970 (mfr.'* Mria!Qrjaft l?\.W1. ifti. No.) Ouri9dlclionaJ no.) (other) (yMr buiH) d: Construction Code Valve o:>de 1968 N/A ~N~V~A=--------~ -~~-2~~~~

(9Clitlonl (addenda) (Code Cae(a)) (Code Class)

6. Section XJ 1983 SUnmer 83 N/A (edlllonl (addenda) (Code Cue(*))
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacemems were made: 1983 S83 N/A (edHlon) (addenda)
a. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *
                                                                                                                                *Draft Plmp & Valve ~~~nion1                                                         1..scienda)
9. Design responsibilities PSE&G ~.......;;..'--~~~~~~~~~~~~~~~~~~~~~~-=-~~-:---,,:--:---.,.-~---~~~...-~----
10. Tests conducted: hydrostatic a pneumatic a design pressure a pressure psi Tenp. NOP system Insel:vl.oe Test
11. Description of work Replaced mecilanical seal in kini fran folio.
12. Remartcs: _....;Wo~ir.~k'-Order~==~#.;;....:. . .;.9. .; ;1;_0.. ;. .72., _5;;. . ; 1; . . ;0. .;o; ;l_ _ _ _ _ _""'De~fl.~*c;...;;;i=m;y~~Rep?~..;;.rt::...;;;....:#.....::.....;;..;,N/t..,;A~--------

Deficierq Report #: N/A Rev. N/A See attadled pages for Description of Replacement. N/A CERTIACATE OF COMPUANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Ce<tificate of Autho<l*a*on no. 36 i ID""' th* "NA" Mamp a,..;<es ~ , 19-94-. Date .3 /°'.3 t9,q,t,. S:gned PSE&G CO.-bh::lear Dept, Q *J_t_ Primipal Ergr. (._ir cx;anizallonl jaulhOllzed '8P'9Ml"llallw) {tllle) CERTlFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure yessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by ArkwrI; t Mltual Insurance Co of M!, have inspected the repair, modification or replacement describe in this report on , tJ- , 19!:f..l_and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection ..

   *Date        'J-2,,..,I I
                                  ,19~Signed ~~ z..,                                                            /' /
                                                                                                                     ~
                                                                                                                              /                                                            Factory ImbJal System
                                                                                                                                                                                                    .3'----------

Commissiona.----'/\kr.-"'-'..._.J<-&..t'..... (Authorizect lnapeclor) (Nall.Bd.No.Qncluding endOlsementa)-* or prOYi.- and number) may be obtained from The National Board of Boller and Presisure Vessel hspeclons, 1055 Crupper Avenue, Columbus, OH 43229. NB-al Rev.6

FORM NR-1 REPORT OF REPAIR = MODIFICATION = OR INS_TALLATION OF REPLACEMENT($)~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

   , . Won.. performed by ~lie               Service Electric & Gas Co - Nuclear Dept                                                           CIP #S-91-287 1name1                                1re~rr organ1z*t1on*s P.O no .. JOD no .. etc.J
  • -Foot of :a.itt:c:a'.1WC Read, Hancoclcs Bridge, NJ 08038 1address1
2. Owner FUblic SeJ:',rice Electric arx3. Gas Co - Nuclear Dept, (name!

Foot of Butta:w:iod Road, Harxxrks Bridge,1address1 NJ' 08038

3. Name. address and identification of nuclear power plant Sal em C-.,eneratj rg stati m IJnjt # 1 F'rXJt of B rttorwxxi Raad, Haryrcks Brj dge, MI 08038
4. Identification of system Senzice water systAn Nuclear Class TT
5. a: Identification of component repaired. modified or replaced _ _.1...,51..,$W58.....,....__,,(rKva..-l.... Vi~e"°)________________

b:. Name of manufacturer -~Ma&:&01..,Sow.une...,.j....J.,.a,....n.___ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ c: Identifying nos. NOOJ J 3-4()-5 NIA N/A 1974 1mtr."s serial no.I (Nat'l'BCi. no.) Uunsdictional no.I (Other) (yHr built)

6. Applicable section(s) XI of ASME Code, 19___8.3__ edition 1983 addenda Sunmeg Code Case_~N~/'""A...__
7. Design responsibilities _ _ __._J?SE~...&G....__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
8. Tests conduc:ed: hydrostatic - pneumatic = design pressure
9. Description o' work _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
                                                                                                             =        pressure
  • NOP psi.Visual leak Exam.

fuse of additional sheeUSJ or sketchtes1 is acceptab1e 1! prooe'1y 1dent1fied) Weld repcd r valve lxrly arrl ~l aa:od flange bol t j rg.

10. ~mllrtl:S: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
JL ii) #910807095 IR #SMD-91-341 CERTIACATE OF INSPECTION I, the undersigned holding a valid commission issued by The National Board of Boiler and Pressure Ve;;sel Inspectors, and certificate of com-petency issued by the state or province of New Jersey and employed by Arkwright Mutual Insurance Co
  - -........----,........,------of Norwood ,MA have inspeded the repair, modification or replacement descnbed in this report on ~- 2D            19Cf /        and state that to the best of my knowledge and belief, this repair, modlic:ation or replacement has been made or constructed in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB 102 current editi>n.

ig'*'g this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the repair, moc1rlc:ation placement described in this report. Furthermore, neither the inspector nor his employer shall be iable in any manner for any personal injufy

 . or~ damage or loss of any ki                         "sing from or                       w* h this inspection.                ~ MLitual. System Date     q-/()         19q/ Signed                                                                     Commissions~M~-~~~~--,...-~----,----

N111 . no.~~) lllleOtpnMIDand ~ This form may be obtained from The National 1;3oard of Boiler and Pressure Vessel Inspectors, 1055 Crupper Ave., Columbus, OH 43229

                                                                                              .                                                                                             NB-81 Rev. !

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) ~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of 1 Public Sezvice Electric & Gas Co. - Nuclear Dept

  • CJP #891-306 Work perf ormed by i-t Foot of Buttonwood Road, Hancocks Bri~e!~

organlZa!lon'* P 0. no. job. no .* etc.) 08038 Public Service Electric arxi Gas Co. (adC*...I 2.0wner------------------------------------------------

                 -Foot of Buttonwood Road, Hancocks Bri~-;'9ID                                                             08038 sai'e1W"/Juclear Generatin;J Station                                          Unit #1
3. Name, address and identification ot nuclear PQ'lillr plant~-"iih-r..ir-rl..---ta:=t--f~~~------------------

Foot of Buttonwcx:x:l Road, .tial1CCX::JG BI iQ;;je, tu 08038 ReactOr COOiant Huclear Class I

4. System
                  *~------------__,IPS,.....,.~1...-.v~ai....,..v"""er-----------------------------~
5. a: Component repaired, modified or r e p l a c e d . . , . . . , : " ' T " ' = = : : - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

b: Name of manufacturer Copes can 1969 c: Identifying nos. 691095002163 N/A N/A M;'A (~IJ'Uiii> & (Neri. Bel. No.I Qun.d~~ no.) (olhet) d: Construction Code Valve 1968 N/A ft/ /'1 (edfflonl

                                                                    ~--------                                      -------------                                    ~---------~

(Code Clusl 1983 Slmlmer 83

6. Section XI 1.attion) (add*ndaJ l9~ ~~3 N/A
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: _ __
                                                                                                                                                     *    (edH~9 68 (ad~                       ~Case(s))
a. Applicable edition of Construction Code under which repairs, modifi~~ r~~mgnttr~~~ade: _ _ _ _ _ _ __

(Code) (edlion) (..idenda) (Code Cae(s))

9. Design responsibilities PSE&G Temp. N/A System Insexvice Test
10. Tests conducted: hydrostatic C pneumatic C design pressure~.ent~~nbl;:'p psi
11. Description of work ReplaCed. cage, plug ard *

(uoe ol llddHiOnal llhMl(a) ot -cll(n) io acceplable ff ptOper!y ident&d) work oraer ' : 9102~~~~4 f)eficie:ncy Report: #: SMD 91 377 Rev. 1

   *12. Remarks: _________,-,--,..,,..,=~........==-'"""'"'--f..--........_____-'l!_ _

oes1gn C'lal'tje Padkage: N/A .nc v..-.-*"""'v.,o.;'A------------------'-- n see attadiea pages ror oescription of ItepldO:!lrent. CERTIACATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair. modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of ALlthorization no. 36 to use the "NA" stamp expires Oct. 3, , 19~. Date.- ¥/re 19,C}_k. Signed,_--=PS=E&G=--'Co~.--'-Nuc:......;;:..__;l:....;.e_ar...;...._De___..pt_. 0 -I. 6~/'(_i Principal Engr. (rajlair organization) CERTIACATE OF INSPECTION I, the undersigned, holding a valid commi~&:r~l'be National Board of Boiler and P~.f~~nfM~~Cl!Petency issued ?l. the state or province of iy and employed by----------~------------ of MA have inspected the repair, modification or replacement describe in this report on 112/lf , 19_2L.and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in* any manner for any perso~n:~~= loss of any kind arising from or tpS~i~F~ Date ~, IJ? ,19~Signed ~ Commissions !llffib6:, /\/J'Jp,:L'j f (Autholized lnapeclot) (Nml.Bd.No.Qncludin; endonementa)-* ot province and number) may be obtained from The National Board of Bot"ler and Pressura Vessel lnspec:IDf'll, 1055 Oupper Avenue, Columbus. OH 43229. N~I Rev.6

FQRM NR-1 REPORT OF REPAIR i MOOIACATION 0 OR INSTAUATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS ANO SYSTEMS IN NUCLEAR POWER Pl.ANTS Paqe 1 of 1

 .or~             pertormed by        P\X>lic Sezvioe Electric & Gas CO. - Nl.x::lear Dept.                                                                              CJP *592--097 i-*                                                               ~r cw~*a               P 0. no. JOt> no.,91t.:

Foot of ~ Road, Han:xx::ks Bri03e, :ttr 08038 1--1 2.0wner _ _ _ Pllb_l_i_*c_Servi __ ._ce __El_ec_Lr_i_c_._am __Gas _ _co_.________________________ Foot of ~ Road, Haixx:x::ks Bri~, NJ

                                                                                                  .      (,,.,,,.;

08038 (ldclrnml * *

3. Name. address and identification of nuclear power plant salem Nuclear Generatln3' station Unit #1 Foot of ~ Road, HarcoCkS Bri(:lje, NJ 08038 4S~tem _ _ _Sexv __i_ce __wa_ter ____~=-==--------------------NUC_l_ear __c_l_ass __!_I__

5 a* Component repaired. modified or replacec: 15SW72 b:Name of manufacturer Mascxleil-=-an---------------------------------~ c: Identifying nos. N~ll3-39-5

  • N/A N/A N/A 1974 tr+. *, _....,. "<>.: .....r;. Bd "'o. Ounodicl*ol'lA "'C lother.
                                                                                                                                                       '\'"' ,.,/-".
::.y.s:*~:: :.* :,,:;::~ ASY:=. Sec. ::::: 1962 .,.;inter 197C _,

ANSI ~._,7 1969 Ed. 197a0,.~. ic.:.o. ~ISi i 6 Section XI 1983 Slnmer 83 N/A (9dHion) (add9ndal (Code Case(1J)

7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 _N"""/_A_ __

(9dilion) (addendml f:.ode c-s;.

8. Applicable edition of Construction Code ul'der which repairs, modifications. or replace!Tlef":tS were made. _'*__ 1968 W70 N/A
                                                            *~ Sec. III/ANSI B31. 7 1969 Di. 1970 ~*l tec1111on1                                                                         taddenClml         (Code Case1s; 9    Design responsibilities_FSE&G     _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

10 Tests conducted: hydrostatic D pneumatie a design pressure D pressure N:>P psi '!'alp. N/A

  • other Description of won. Performed '#eld repair on valve bc:dy.
                                                                 !UM cl lloddilional ""-'l*I cw -chl*I is          ~ i ~ idenllfied)
12. P.emarks Werle Order #: 920206078
                     ---:-=-----.-~---:--~-..,,---==-....,,.....,,...--=--::--=-------------~-------------~~

Deficierx::y Report #: SMD 92-384

                          *System In.service Test Perfonood at OOP CERTIFICATE OF              COMPUA.~

Vve ce11ity tna: tne stateme~~ maoe 1n this ;epor. are correct and the repau. modif1cat1:;~. :; * *ep1aceme-: of the item~ oescrioeo aoove *conforms to Section XI of the ASME Coce ar:id the National Board rules as defined in the publication N&-102, curren: edition. Cert_ificate of Authorization no. Ji to use the "NA" stamp expires Oct ~ , 19-$4-* Date 7/7 19,jk Signed PSF'bG Ch.-Nuclear D?pt.

  • 1'91>&1* or;anizatlonl Q.:f.~_k

(*utt>or.:er: ~I Principal E'J'Gr. (llllel CERTIACATE OF INSPECOON This form may be obtained from The National Board of Boner and Pressilre Vessel Inspectors. 1055 Crupper Avenue, Columbus, OH 43229. NB-al Rev.&

' t- *

                                                                                                          ~'JD-'Z I                                I          *                      -1 J.                   .. 5dS t-"01{\l ~l'\'.J \l.\:\(11.\("ll 1n I~'-'" 11'1 \ l~l l'Ol:I 101: 'nl.1.\1: l'l'\ll"S OI~ \".\l\TS
                                                  .\* .-. .. r:.-,J h :': 1*, .., ****: . **I *' II l"*c.* 1<1;'. .,
      =--*      -~:--**    -                                                                                                                                                ---*.:.._-_      ---~-      .:..-.-==
.~.L~:"' ::,* ~ 1!'1 I ?.lf*!"':-:.-:' :,::: .. ! , I:.*_*.

I, ~l.*1:.1,_.;111~*u It~ ' ; e

..' . .' .. :1 ' :_' * ._ , :: "..'* ' I, ." -:
  • 01tk1 :-. ... !:-001~-:~;-l- - -

I ' .. 1t * ' ;.. \ '. -. ** .. : * '. **.*. I,.,' I

                                                                                                                                                                                                    ,..z l~>!ic S;.'n*i~                                  J'.1 . . . :-:tric          ~      C..:!; Co.
      "I                            (l*J   1*.*11: l'!.:..: . .-                                                                                                       I.:1:06959                   -3
      *. M;:*111f 1.1ur"J r.*1 ........... "J . - \,,                                                .                                                        Ou.1,*r  ~..       _ _ . ___          ~-1
                                    *  ....... 1. I    **         uI          ........ _     .o11:hl  ;..;.!,, .)
                                                                                                                                                                                                  ....-5
3. (lwr;,*r _________ !'..;!;lie.: Si..*.:..-:io.; J..:lc:'!'.r) c !.- G..!!"'. Co ** ______ ... * - - . _ -
4. l.cx;11i1*11 of l'l.1111 _S~l'=°:;J:~::}c:**~--~.:.*r.-::.t~::-J S~ ..1t.io:l, t,;~its lf:2, r~.hrn, =~
      '    l'un:;" l"r \'cl'l° It:::.:*-. ..               _ 1:..*             .~:               -.    ~;.'    ..              ...... ,                            E                     i

____ S0!""':i 1..' : ' _ \*':.':-:*!.* : .. ?:*,:-)*.:'*:"':_;.!"\ ....: - -- --- - ---- 1**.-. I "'*r1;~** *. * :\h** 1.. 1 \\!,.,,,h '"iJll' .. Ja! ~ ...... -*:h.JJ

                    * * ,,                     1'.8599 D                                                                       R D ""---"

():i Dr:iwini; *'"'* ___ - - - - * . _ l'1cp;u.*J l*y_ *-**-=-- ~--~~~"'-:~-------------- Edition ~._1_2~_8--J

                                              \lie ...... ,
                                                             ?tn U. &..l\..>l~U '-'U*l\111 hlHI - - - - - - - - - - - I'~*.--_
                                                       .r\t.IJcm.l.1 futl' _~~~LWJ..9_
                                                                                                                           ;>no
                                                                                                            , **.*** ,,.4 ...... ,
7. T11r m:ih:ri:il, Jesisn. coa)lructiun, ;inJ w.icl;111;i11>hi1' (1*:11pl:~*s witli AS\ll C:11Jt S::-..::i.*11 Ill.
                                                                                                                                   *- -- I fnc St'*--------

Oraf t for P&V n.1., 2 Ma~ ~u~ ~ ~1:1-"Ti=~~~-~~~~[~ --~J~::'~~~:t--L __ R-7n:.J:l\

                                                  ---t..s.:r_: ;,.;~2Hi                                                    I ct::*.N.:i~

(:tl_ C':n1in.!J F8969-l

            --=-~----~~~-~:r==---::--~1
            ----j.*~:;*(~f-.;                 ____
                                                                                        *It~-=:_-_- r~--~--~~-------~~
                                                                                ----- - -                                -i----* --- *-                          --r---

(.=-_ JJCDY

            -----::~, -~=~ :.~- ~~:s~~1--~--~-~~-, ~:~-~=1i--\-,-.,.-,-.---   ._._.,*..I - *,,,. \

1.1..A,, * ..... ~. '..ii .....

-:.;2----- ,_,..ri~l-'.*;*. - - .-* - ---~---- .
                              --.:3                         .                  *-*-- '-----,---                                                            -.-     ...
            ---                      -.i-                                      _______ _J                                                           .          _J __

e -5

            =---=-

(~h>l£i~

                                     ..        -                        .:l.-=-=*-==1=-=.;..:_-

__ , _________ *----**-----1--

                                                                                                                                                        .. ~=1:.....-::--=--=--=-~- --
            ----------*----*I -- -- - *-* -* I* -**- ------
  • wcr sos
                                                                                                                                                        ; j *I l OH \I :'\I'\'* I I1 ~-1.   :r.i.11 Sj* .*.     ~.
  • I I*

L

                                                   -* .   -*i                                       l I

j I

      -----*---**- **-                                                                              I I                             --.    -*-.    *-    *-----------

I

      - 01** -,,- -**1;*?.()r *.** .

I

                                                                                                                       \.

(d~I :..:!_ ..11)'*- '** '-'*:.: __ . _ *-  : *  !;*.' 1

                  -------* ______ '.i*:*;-.: _\JG__ _

J CD:l IFICATIO:'\ OF l>LSIG~

   ~n i11fo1111:.ativ111lll f1h- :ii ___ !*~c:.*:il..!! .. lntl.!!'~:!L.il.::'...:11... * .l."'l~- - - - - - - - - - - -

Su~' ~i.:1'pi, 1rp.*1t un f1!l* :11 _ * - __ _ . ~ __ -* J..:..-\ _... _____ . _. _ . _

  *l.A.~:-n )p*:*il1.:~t1111I, .:c11i!111l b) _-~::r. :':-:ll'..:.~~:i                                          (11 l'ruf. l.1*. St..itr _E.J _. ~-;. Sl*. ~-G~::-;_7_

Str~;in:.:l)~i~11*purlci:!1ilt.-1lh)". --~"'*~-

                                                               ' ...                   **-*****. (l)l'1uf.l1:1'.~l..ilC :..:.~~-- *~r;"-~U. ;,,i
                                                                                                                                                 , ~.                           ' -.

(I) Sifn:.hir.: nol IC'<111i1i:d. u~111 *.a:: o:.*y. We crrtif)" th:i1 thi: ~l:item-:rits m::Jr in 1!1i' *~! :iic "'~ll"d. Si;::::IJ =~: ~or:c i !~*'.*_ lr_1t_l. *-. IJy . .!...: _ .. /.!_.r ...-

                                                                                                                                        ' /.'l' .*"
                                                                                                                                                .   /
                                                                                                                                                      "'7- - - - - - - -

(~1*'1*1~. hlh I) t:-8!:17

                                                    *-----*------ -                                        --------------------~

CERTIHL\TE OF Sl!OI' *~~:l'r:cno~ l!lc Sb!:"' P1..,..*1ncr ul - - * - - - - - - - - - ~nJrm;*'* *cJI*) - - - -

  • _ _ _ *- ____ * - - 19 ___ , ,.:)j ** *'< ll:..11 1,* 11.c t-r .1 ..r r.i) lh**.. J.*J~.* ..ir.J 1, ! ** r. it..: '-!*n11fJ, 111:c1 ~. c...c*:r1x.kd lt-.it c°'ui;*in<"nl 1n JH*>hl.n.,* "'1lh 111= ";'j'b...il !> Si;\,.~.li.**h ..i """II l ,*J,*. ~.: ... .,Ill.
        ,J   U.*1111; ll:k r~ 111r1o*~rr. *** 11h.:1 11,.- In*;,-. ..., ...... , t:. .. r* ,...:..,.,
  • r:,_.i. ... J'-. * .. u ... :y. r* r1r-*..,J "' ir..;~ J. , .. ~ c: ~

lk l"'*"rr.1 Jc .. 111*.J 111 1111. l* .. r.1 k*;-*11. I "111..-11:1..sc . ..-.. ,:1 :1 l!.1* It . ., ..* ,,., r.**1 L*' .-i.*11 .. ;oa ,p._n ,... L..t!.- 1:1 .. ~,

  ~I f,,, ~!1)' f< '"ll*l lllJUI)"  l"l'"> J .. rr-*;<' .., ~""**I-) l 1:~1 ..111*..tr.;- l .* *m **I'"""'"°' IN ~11la t!.n ta.~*:J.*IL

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) ~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 Work perlormec by Public &ilvice Electric & Gas Co. - Nuclear Dept.. CJP #S92-155

  • Foot of Buttorrwood Road, Hancocks Bridge, NJ 08038
                                                                                                                   !acJOrnsl
2. Owner _ _-=.Pub-==-=l=-=i=c:.......=Seivc=-'-=i=ce=---cE=l=ectr~~l=*c::.__;:arrl==-=Gas:..==:......-=Co=-=-*-----------------------

(rwne; Foot of Buttonwocx:l Road, Hancocks Bridge, NJ 08038 (add*-)

3. Name, address and identification of nuclear power plant Salem Nuclear Generating station Unit #1 foot of a.rttorrwood Road. Hancocks Bridge, NJ 08038 4 System Cemineralized Water Nuclear Class II b: Name of manu1acturer 5 ~Componeru~p~*~.modffiedm~p~~d~-~~~-9--------------------------------~
                                                       ¥..asoneilan                   ________________________________

c* Identifying nos N-OOJ 01-1 N/Aj N/A N/A 1973 imh ."s seriai no.1 (Nat'I. Bel. No.I Quri9dict1onal no.) (olh*r) (yea* buitt~ d Cons:ructio:-* .:,,ce ASME DP&V J 968 3/70 NIA 2 (edtt*on) (Coo* C&se(s); 6 Section XI 1983 SUmrner 83 N/A

aooertoa: (Coo* :.a....11);
7. Applicable editior. of ASME Code Section XI under which repairs, modifications. or replacements were made: 1983 S83 N/A P>cle C-(s)l
a. Applicable editior. of Construction Code under which repairs, modifications. or replacements were made:
  • N/A
                                                                                                              *ASME DP&V                                                                             (addenda.
9. Design responsibilities._.J=i;:,g~---------------------------------------

10 Tests conduC1eo hydrcs:atic D pneumatic a design pressure D pressure NOP psi Temp. N/A ** 11 Description of work Bepl ace (8) bonnet sprj5 arrl nuts arrl (16) !lafl9e nuts and (8) studs.

12. Remarks: _--IJWoo..u..r.Llk__._.Ordu....u""'e..._r~~~:_9 ....2"-'0w.3..u0,,,,.5...,0,,,_.7.__.7'-------------"r::e..,..,.f...,j..,.c""'i..,.ercy......,,<J--_._Be,po~~rt.~..11.#~:---!.liN~/A2.___ _ _ _ _ __
                          -Cesj gn            OJarqe Package j : N/A                                                            Rey.      WA
                           **system                 Inservice 'Iest @ NOP,INOI' CERTIFICATE OF COMPLJANCE We certify :na: tne s:atemen:s m.:.oe 1n this 1epo~ are correct arrd the repair. moa1f1ca:1on or rep*acemen: oi tr:e nems descr;oeo aoove conforms to Section XI ol the ASME Code and the National Board rules as defined ir1 the publication NB-102. current edition.

Certificate of Authorization no.

  • 36 to i.:ss the "NR' stamp expires ~j~ , t9-*.

Date : 7/9 19.C/2. Signed FSE&G Co. Nuclear D:!pt. (r*oa.r e>rgL~*Za!JOnl Q ~l-e,"iJ; (author'.:..s '-;><.wntar"'9J Princi~ FJ"Jgr. lei CERllFICATE OF INSPECTION I, the undersigned. holding a valid commission issued by The National Board of Boiler and Pressure Vesssl Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by kwri t Mutual Insurance Co of ~ have inspecied the repair, modification or repla~ment describe in this report on - , 19£..f:.:.and S1ate that to the best omy knowledge and belief, this repair, modification or replacement has been made in accordance with Section XJ of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty. expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any person injury or property damage or a loss of any kind arising from or connected with this inspection. Date _7_.__:.,~/-"--__ ,1H l-signed -C:. Crk commissions ~m Mutual System V\ulhorized lnspectot) (Nall.Bd.N<>.pncluding endorsemenls)S1ale 0< province and number) rm may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB*81 Rev.6

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of l

         ~ performed by            FUblic service Electric & Gas Co. - Nuclear t'ept.                                                                                C1P #S92-168
                                                                                                          ,........,                                                      (rwp&tr ~** P. o. no. job. no.,91c.)

Fcx:>t of J3utton'WOOd Road, Harox:.ks Bridge, NJ 08038 .

2. Owner _ _ _ Pub

__ l_ic_Serv _ _i_*ce __El_ectr_ _i_c_arxi _ _Gas __ eo_.- - - - - - - - - - - - - - - - - - - - - - - - Foot of Buttorrwood Road, Hancocks Bridge, __ (name)

                                                                                                    , NJ         ,
  • 08038
3. Name. address and identification of nuclear power plan1 Salem Nuclear Gene.rat~ station unit #1 Foot of aittorrwood Road, Hancocks Bridge, NJ* 08038
4. System Containment Buildirg ElectricaljMechanical Penetrations Nuclear Class II s a: Component repaired, modified<>r replaced l.RCE35 Personnel Hatch
                                                            -.=o,~=-:~;...="-"'-_..:..;;--'-"'--_;;,:..;.....;;.;...;;__      _    _  _  _    _    _   _    _    _   _    _    _  _ _ _ _ _ _ _ __

b: Name of manufacturer Oricago Bridge & Iron c: Identifying nos. 2668 N/A N/A N/A -------- 1970 (mlr.'s .rial no.) (Nal'I. Eld. No.) Qur!adlclional no,) (other) tyMI buift) d: Construction Code ASME Sec. III 1965"'""_W_.Y~6""'"7.;.........._ _ __ N/A N/A PS Spec. S-C-1968~7123 (addenda) {CodeC-(s))

6. Section XJ 1983 SUmmer 83 N/A (edHlon) (llddendaj (Code CU.(a))
7. Applicable edition of ASME Code Section XI under which repairs. modifications, or replacements were made: 1983 _S_8_3_ __ N/A (edlllan) ~~l
8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made:
  • 1965 N/A
                                                                                                  *ASME Sec. III/PS Spec. {Code) 1ec:1111oni                                         ladd9ndal
9. Design responsibilities PSE&G S-C-1968-I:SP-7123
10. Tests oonducted: hydrostatic a pneumatic c design pressure a pressure N/A psi Tenp. N/A **
11. Description of work Replace air lock personnel hatch hin::;Je not performed, weld repair (UM of additional 1Met(1) or lketch(*l ia acceptable if p<opetly ldenlllied)
  • to seal in; area.
12. Remarks: Work Order #: 920211128 Deficiency Report #: N/A Design <llanJe Package #: N/A Rev. N/A See attached pages for Description of Replacement. N/A
                          ** No System InseJ:Vice leak Test required.

cefmFICATE OF COMPUANCE We certify that the statements made in this report are oorrect and the repair, modification or replacement of the items described above oonforms to Section XJ of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate /of Authorization no.

  • 36 to use the "NR" stamp expires Octa 31 J , 19-94-.

Dat* . ~1Z 19,qz. Signed :ESE&G co -:bluclear Dept. Q.J' ./J(,,,!f.:li Principal Engr. (repjllr orvanizallon) (aulhor'.z9d ~) (lllle) CERTlFICATE OF INSPECT10N I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure ,Vessel Inspectors, and certificate of xcmpetency issued by the state or province of New Jersey and employed by Arkwright Miitual Insurance C.:O of MA have inspected the repair, modification or replacement describe in this report on f, / , 1~ state that to the beS1 of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XJ of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, ooncerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer Date i l °],, ,19qy,Signed q_~Ir. {.J.-vl.,.,-

                                                                               //

shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or oonnected with this in~on.

                                                                                                                                                        ._P...cto;t.Y Mutual System Commissions.---'AJJj~~c...1-1,__S~--------

CAuthorizod ln1poctl>I) (Nall. Bd.No. (lncludlng endommenl1)ltal* or PfcMnat and number) may be obtained from The National Board of Bot'Jer and Pressure Vessel Inspectors, 1055 Qupper Avenue, Columbus, OH 43229. NIH! Rev.II

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) .EJ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of) iefl'

1. Work performed by Pllblic Service Electric & Gas Co. - Nuclear Dept. CJP #S92-179 (name) (repair 0<ganization'1 P. 0. no. job. no.,elc.1 Foot of Buttonwood Road, Hancocks Bridge, NJ 08038
                                    *                                                 *      (addr...)
2. Owner _ _ _PUb __l_i_c_SeIV__i_ce __El_ectr ___ ic_ani __Gas __ eo (name)

F?J"t of Buttonwood Road, Hancocks Bridge, NJ 08038 (addrea)

3. Name. address and identification of nuclear power plant Salem Nuclear Ge.neratin; station Unit #1 Foot of Buttonwood Road, HancoCkS Bridge, NJ 08038 4 . System Olemical Volume Control NUCiear Class II
s. 1CV171 Valve a: Component repaired, modified or replaced b: Name of manufacturer Masoneilan -.-:------------------------------------
-7:~--------;-=--.:-------~---:=-;;---------:";"7";;----------,,-,===-----

c: Identifying nos. 2X42D N/A N/A N/A 1988 (m~ ~ ~el.cNo.) Qurisdic:lional no.) (olhet) (yMr b<rift) Valve Code 1968 N/A 2 d: Construction Code ANS I ~1.., 7 1969 (addenda) jCode Cue(s))

                                                                                                                                                                  -----------      (Code Class)
6. Section XI 1983 Stnmner 83 _N_,_V_A_ _ _ _ _ _ _~---

(edition) (addenda) . (Code C:U.(s))

7. Applicable edition of ASME Code Section Xl under which repairs, modifications, or replacements were made: 1983 S83 N/A (edttion) (addenda) (Code C-iSll 8 Applicable edition of Construction Code under which repairs, modifications. or replacements were made: ANSI B31. 7 1969 NIA a.'f-
                                                                                         *ASME Draft Funp & Valv~~~                                                        (addenda)          (Codec-1su
9. Design responsibilities PSE&G
                               ----------------------:-:==~----=~---:=-;;--:---:---::---"T"---=-

, o. Tests conducted: hydrostatic a pneumatic a design pressure a pressure _NO __ P_ _,psi Tenp. N/A system ~ice Test

11. Description of work Replaced lx>ltin;J (UM of lldditional lheel(1f or ....tch(n) i* acceptable ~ pcope<ly identified)

-~~~~~~~~~-

       .,._ ar1c       Work order #: 900203005                                                                        Defici.::i.TY'"U' ~ #: SMD 92-302
12. ..,..m s:_--:=-...,.----:::::-----=:--"';----.,,-~=-=:------=----=~=---~-~--=-i~~""'"1:""'-=--*-------------

Design OlCln:le Package #: N/A Rev. N/A

                      *See attadled pages for Description of Replacement. tJ/A ait.

CERTIFICATE OF COMPLIANCE We cen1!y that the statements made in this report are correci and the repair. modification or replacement of the items described above conforms to Seciion XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. Jf; to use the "NR" stamp expires J~* J , 19--94-. Si~ned Q V ~tvtlr 1 Date ,.t/fi 19,02.. ffiE&G O> -Nuclear (repair °'gan.izallon) I):pt.

                                                                                                                            \eUlhOllZed repreMnlallw)

PrjncjpaJ

                                                                                                                                                                              ~ttle)

ErJiir. CERTIACATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Y~~I hJ§p9ctort. and certificate of competency issued by the state or province of New Jersej and employed by Arkwrign~ z.D.lOlal. ~ Co of MA have inspected the repair, modification or replacement describe in this report on -!ft , 19..2G__and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NS-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair. modification or replacement described in this repon. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal in~ or a loss of any kind arising from or connected with this inspection.

                  .                               ~                                                                                            Factocy Mutual system Date     Cfici-      // .19~       Signed (Au\ho<ized ln1pectCH)
                                                                                                    .              Commissions       N8 7'6"'-                 Nfrloa?.f (Nall.Bd.No.(lnc:ludl"9 e~)llale °' ~ IUld number) may be obtained from The National Board of Boi'ler and PressUre Vessel lnspectDta. 1055 Crupper Avenue, Columbus, OH 43229.                                                               I N8-a1 Rev.6

FORM NR-1 REPORT OF REPAIR 0 MODIACATION 0 OR INSTALLATION OF REPLACEMENT(S) ,L! TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 Work performed by Public Service Electric & ~~* - Nuclear ~* CJP #S92-188 (rep.jr ~** P. O. no. job. no .*.ic.1

  • Foot of Butt.aYwocxi Road, Harx::ocks' Bri¥ 1 NJ 08038 (8ddr...)
2. Owner _ _-=.Pub.==l=i-=-c-=SeJ:v=-'-=ice=_El=ectr=-=l.=*c~an:i=~~='---==Co..::0..:.-.- - - - - - - - - - - - - - - - - - - - - - - -

(........) Foot of aittonwocd*Road, Harx::ocks Bridge, NJ 08038 (lldchm)

3. Name. address and identification of nuclear power plant Salem Nuclear Generatirg station Unit #1 Foot of Buttonwocd Road., HarQx:ks Bridge. NJ 08038
4. System Safety Inject.ion Nuclear Class I
s. a: Component repaired, modified or replaced lA-SI-SNlOOA-Medlaniqal Snul::ber b: Name of manufacturer Pacific Scientific c: Identifying nos. SJN 450 N/A WA N/A --=1=9-'-7-=6_ _ __

(mlT .'s 9Mia1 no.) (Nal'I. Bel. No.) Qurlldictional no.) (olhe!) (year buift) d: Construction Code PS SnubQ:>r Spec. 73-6402 N/A 1 ANSI Dk7 1969 F.d. 19M.,rM:i. lCOde Cue(1)J (Code Class) 6 Section XI 1983 sumuer 83 N,/A (odltion) (addenela; (Cod* Cas.(1)) 7 Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 $83 N.,../.a.AL..--- (edftlon)

a. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: -*-- ___ _ __
                                                       *ASME Sec. III 1974 576, ANSI B31.7 1969                                                       E'dCodi97&n~.~                                   !Code Case(1)J
9. Design responsibilities J?$E&G FS Srn:ifter Sp;c, 73-6402
10. Tests conducted: hydrostatic a pneumatic a design pressure D pressure N/A psi Teltp. N/A
  • other
11. Description of work Eepl aced ny:dian j c.a 1 srn uter S/N 4 50 with vedJanical srp Jbter (u. r:I. adc!Hional ..--(1) or -ch(*) ii ~ N p<ope<1y idenllfi..:I)

S/N 25872

12. P.emarks. Work Qrr3er #: 920919026 Dafjciency ~ #: N/A re;ign Olarqe Package #: WA Rev. N/A See att.adled ~ for rescription of Replaoement I N/A
  • VI'-3 Presendoe Exam CffiTIFICATE OF COMPUANCE We certify that the statements made in this report are corr&Ct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition.

Certificate of Authorization no. to use the "NR" stamp expires CX;t. , 19-94-. 36 31 Oat* : '1/ S 19, 92.... Signed FSE&G Co. Huclear l):!pta ("'l'&k orll&"izalionJ (] * :/. flvvt:= (aulhot'.zlOC! re~allwJ Prine~ I Erqr. CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by kwri t Insurance Co of MA have inspeCted the repair, modification or replacement describe in this report on Z , 19 t;'Z- and state that to the . best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty. expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal inju r p party damage or a loss of any kind arising from or connected with this inspection.

             ~~~""---' 19~ Signed                                                                                             Commissions         J)t ~1J~System (Authorizad ln~OI)                                         (Nall.Bd.No.(lncludlng ando<somonts)olale or prOYlnee and numbel)

I rm may be obtained from The National Board of Boiler and Pressure.Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NEHl1 Rtw.6

FORM NR-1 REPORT OF REPAIR tJ MODIFICATION 0 OR INSTALLATION OF REPLACEMENT($)~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 Work perlormed by Public Service Electric & Gas Ol. Nuclear Dept. CJP #892-190

                                                                                                                                 ,,,.,,..,                                                          I-~** P                             o. no. ;oc. no.,stc.)
  • . Foot of l3utt.onw1oOd Road, Harx:ocXs Brid:]e, NJ 08038 (9dd-)
2. Owner _ _ _ Pub_"""l"'""i"""c_SeN

__ ice__El_e.ctr _ _i"'"c_ard _ _Ga_as __Q)-"--*- - - - - - - - - - - - - - - - - - - - - - - - (nam.J Foot of Butt.orl!i¥ood Road, Han::x>cks Bridge, NJ 08038 (add'-)

3. Name, address and identification of nuclear power plant Salem Nuclear GeJieratin; statioo Unit #1 Foot of Buttonwoc:d Roaci, Hancocks *Bridge, NJ 08038
4. System steam Generator Feedwa.ter Nuclear Class I
s. a: Component repaired, modified or replaced LS14-EWSN-15B Mechamcal Sn11tper b: Name of manufacturer Facjfjc Scientific c: Identifying nos. S/N 488 (mfr '* M<ial no.J N/A (Nal'I. Bd. No.)

N/A (Juti9dictionaJ no.) N/A (athel\ 1976 d: Construction Code PS SDJ1hter Sp;c: ..L7....3._-_..6=4u.0...2~---- 1644-4 ANSI Dh7 1969 Fd. 19~0erAdd.

6. Section XJ J983 SUJmer 83 (edHIOfl) (addenda) (Code :::..S.(1))
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 ~SB~... 3_ _ N/A (edJllon) (8ddendmj ~ c::-itll
8. .Applicable edition of Construction Code under which repairs, modifications, or replacements were made: -*-- .l224._ S26_ N/A
                                                                                        *ASHE Sec. III/ANSI B31. 7                                                              (Codel           r.cs111oni                 c~                   (Code Cue (IJ)
9. Design responsibilities psF.&G 1969 Fd. 1970 Add .,(PS Srnittier Spec 73-6402
10. Tests conducted: hydrostatic a pneumatic a design pressure a pressure N/A psi Tes:rp. N/A *Other
11. Description of work Repl aa:rl m:chani cal snubber S/N 488 wj th uechan j cal srn 1J-tier (uoe =' llddHiona! lhMl(I) Of ll<Mch(n) ii ~ I pn>pe<ly identllied)

SfN 27911.

12. Remarks: _ __.,Wo!M!.&.r...,k._,,,Onie;~~r---ii:....:~9u2.,,.09J.2..,JJ'-'9._,,o....2.,,.6..___ _ _ _ _ _ _ _ _..,l"P......,.f..,,j..,c,...jUiercy......,q...._.Bep>->11"""""rt ............l#L.J:..........!'i,,,.l...:A.._.-------

I):>;,sj gn Olarqe Package #: N/A Rev. N/A See attad)ed pages for re;cdption of Repla~. N/A

                            *vr-3 Preserojce Exam CERTIACATE OF COMPUANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XJ of the ASME Code and the National Board rules as defined in the publication NS-102, current editiQn.

Certificate of Authorization no. 36 to use the 'NR" stamp expires . oct 3I

  • 19~.

Date la/S 19.U Signed PSE&G Cc. Nuclear {)ept. (1'9PAU Otii&"izlllion) tJ */ ~/,uc k (&UlhOl!zed ~) Prine~ J EA:Jr* CERTIACATE OF INSPEC110N I, the undersigned, holding a valid commission issued by The National Board of Bot1er and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwri<jlt. ~l Insurarce Co of MA have inspected the repair, modification or replacement describe in this report on L , 19~d state that to the best of my knowledge and belief, this repair, modification or replacement has been made in aocordance with SeCtion XI of the ASME Code and the National Board rules as defined in the publication NS-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this repolt. FurthermOfe, neither the Inspector nor his employer shall be liable In any manner for any person~ge or a loss of any kind arising from or connected with this inspection.

        .                                                           ~                                                                                                            Factocy M.ltual ~

Date ,19~ Signed Commissions tAf7!"/o(;J ,AJJ: IW~

                                                                                                        !Authorized ln*podOI)                                       (Nstt.Bd.No.jn:luding ondorloments)lllll*                   or pr.,......,. and numbolj may be obtained from The National Board                                   at Boiler and           Pressure Vessel            mpectors. 1055 Qupper Awnue, Columbus, OH 43229.                                                        NB-81 Re.1.6

FORM NA-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) ~

                           . TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 l?Ublic Service Electric & Gas Co. - Nuclear Dept*                                                                      CJP #S92-191 Work performed by
                                                                                                ,_)                                                          (*-* organization'* P. o. no. jot>. no.,etc.1 Foot of Buttonwoc:xl Road                     Hancocks Bri                             NJ 08038 (9ddrno)
2. Owner _ _ _l?Ub-'-'-"""l_i_c_Serv

_ _ice __El_ectr _ _1_*c_aro _ _Gas ___ Co_.- - - - - - - - - - - - - - - - - - - - - - - - (name) Foot of Buttonwoc:xl Road, Hancocks BricXJe, NJ 08038 (9dd. . .)

3. Name, address and identification of nuclear power plant Salem Nuclear Generating station Unit #1 Foot of Buttonwoc:xl Road, Hancocks Bridge, NJ 08038
4. System steam Generator Feedwater Nuclear Class I s a: Component repaired, modified or replaced 1Sll-FWSN-12B
                                                       ~~~~~~~~~~-~------------------------

b: Name of manufacturer Pacific Scientific c: Identifying nos. 440 N/A NIA NIA 1976 (mf!.'s Mrial no.) (Nal'I. Bel. No.) Ounldic:lionaf no.) (other) (year buiftl d: Construction Code PS Snubber S.pec. 73-6402 NIA 1 ANSI Bah7 1969 F.d. 191i&etAdd. (Code Cue(I))

6. Section XJ 1983 SUmmer 83 N/A (edhion) (addenda) (Code C:U.(1))
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 $83 ....N~/'-'A=---

(edftlon)

s. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: -*-- ___
                                              *ASHE Sec. III 1974 S76, ANSI B31. 7 1969 Fd. alS*O ~~/ ladd*ndal
9. Design responsibilities PSE&G PS Snul:ber Spec. 73-6402
10. TeS1s conducted: hydrostatic a pneumatic a design pressure a pressure N/A psi Tenp. N/A *Other
11. Description of work Replaa;d JOOChanical snubber SIN 440 with mechanical snubber
  • SIN 25893.
12. Remarks: Work Order #: 920919026 Deficiency Report #: NIA Design Ola.rge Package j: NIA :Rev. NIA See attadled pages for Description of Replacement. NIA
                        *VI=3 Presexvice Exam CERTIFICATE OF COMPUANCE We cenity that the statements maae in this repon are correct and the repair. modif1cat1on or replacement of the items described above conforms to Section XJ of the ASME Code and the National Board rules as defined in the publication NB-102, current edition.                                                  -

Certificate of Authorization no. to use the "NR' stamp expires Oct. , 19-94-. 31 Dal* (,/ r r; ,.,q_L ~*** 36 mE&G °"*-""" ll<¥* (1-r organazatJOnl Q -.!. °&Wt.k laU!hoNecl ..~, PriK:i,E,'1 ) i:ngr-CERTlFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of

  • New Jersey and employed by Arkwri t Mutual Insurance Co of lQ have inspected the repair, modification or replacement describe in this repon on , 19~and S1ate that to the beS1 of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this repon. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propeny damage or a loss of any kind arising from or connected wi_th this inspection.

l. DateuM.fZ,. 9 ,19£_~ Signed~~ ~ ~ Commissions Factory Mutual ~stem AJ,A'?f66 NJ" JO.;l.ff (/ (Authorized lnspoctOI) {N 11ll.Bd.No.(lncludin9 endcmement1)11at* or province and number) 0 may be obtained from The National Board of Boiler and PressUre Vessel Inspectors, ~055 Crupper Avenue, Columbus, OH 43229. NB-81 Rev.6

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 6' TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

                                                                                                                                                                                               )
1. Work performed by Public Service Electric & Gas Co. - Nuclear Dept. CJP #S92-~ 1Jf3..;,j ct'--
  • Foot of art:tonwood Road, Hancocks Bri~~ 08038 (eddr. .)

2.0wner _ _ _Pub __l_i_c_SeI:V _ _i_oe __El_ectr __1_*c_arrl _ _Gas _ _Co_._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ (name) Foot of art:tonwood Road, Hancocks Brid:Je, NJ 08038 (odd-)

3. Name. address and identification of nuclear power plant Salem Nuclear Generating station Unit #1 Foot of~ Road, Hancocks Bridge. NJ 08038
4. System steam Generator Feedwater Nuclear Class I 5 a: Component repaired, modified or replaced 1S-ll.FW-SN012A Mechanical Snul:ber b: Name of manufacturer Pacific Scientific c:ldentifying nos. S/N 389 N,IA N/A N/A ---'19=-=8=0=------

(mfr.'s NfiAI no.) (Nal'I. Bd. No.) Qur19dictional no.) (CChel) ttMr buift) d* Construction Code PS Snnhp=rr ~ _,_7_..3_-_,,,6"""4,.,.0""'2'------ N/A 1 ANSI Barh7 1969 Fd. 19~erAdd. {Code 04>9(*)) 6 Section XJ 1983 SUnlrer 83 N/A (DdHiOn) (addenda) (Code C&se(S)/

7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 ~N.-/~A~--

(edlllon)

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: -*-- ___ _ __
                                                                 *ASME Sec. III 1974 S76,' ANSI B31. 7 1969 &i<¥ ~, ~
9. Design responsibilities psE&G PS Snptter Sp;<: 73-6402 to. Tests conducted; hydrostatic a pneumatic D design pressure D pressure WA psi Tenp. N/A *Other 11 Description of work Replaced necbanir.aJ srniH?er S/N 389 with mechanic.al SJ]l}j)P..r
  • S,IN 25856.
12. Remarks: _ __,_,wa_r..,.k_Order,,,,.;--..c#~:.__9...,2...,09........,1.,.,9""'02""'6...__ _ _ _ _ _ _ ____..~"=""f~i,,.c.._iercy,,,._,,~_,,Rep:>=~rt_,,,_...._#...._:_,N.,../""A~------

T'ffiign 01an;1e Package #: WA Rev. N/A See attached pages for D=scription of Re!>lacenent. N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code anC! the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. I

                                                   .          36 to use the "NR" stamp expires r~

a*

  • J J
                                                                                                                                                                      , 19_ _ .

J .. Date

              '.~r £           19,f}L Signed                           FSE&G Co. Nuclear Sept.

(,_p Oli&"izClon)

                                                                                                                                                        '~

i&UlhOllHCI ~) Prino~ ~-

                                                                                                                                                                                                     ~

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwright M..rt:ua.l ~ Co of lQ. have inspected the repair, modification or replacement describe in this report on 4/# , 19~and state that to the best of my knowledge and belief, this repair, modification or replacement has been made In accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement desaibed in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal lnju~erty damage or a loss of any kind arising from or conn~;; with this inspection. Date ,19f2,.?Signed =-:& J~ Commissions A.J8'!Y'lf ~~

                                                                                              !Authorized lnopec:tCll)                             (Nall.Bd.No.(lncluding ondo<'Jements)atal* ot p<<Nince and numbel) nn may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Awnue, Columbus, OH 43229.                                                                        NB-al R.v.6

FORM NR-1 REPORT OF REPAIR 0 MODIF1CAT10N DOR INSTAUATION OF REPLACEMENT(S).;£1 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER Pl.ANTS Page 1 of 1 Dept. Wor~ performed by PUblic Service Electric & Gas Co. - Nuclear CJP #892-193

                                                                                                                      ,,...,,,.,                                                   i - ~** P. 0. no. !Ob no .*91<.i Foot of Buttonwood Road, Han:xx::ks BriQ;e, NJ                                                                          08038 (llddrm; 2.0wner _ _ _Pub     __l_i_c_Sel:V        _ _i_ce_El_ectr              _ _i_c_am             _ _Gas   __     Co_._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

(name! Foot of Butta:rrwood Road, Harx:xx::ks Briti;Je, NJ 08038

                                                                                                                  ..,.,,_)

3 Name, address and identification of nuclear power plant Salem Nuclear Generatin; station Unit #1 Foot of Buttonwood Road, Harx:xx::ks Bri.li;;e, NJ 08038

4. System Reactor Coolant . Nuclear Class I 5 a: Component repaired, modified or replaced ___Snubber=-'"==-==-~l~C~---PR~--SN~~0~0_7________________________

b: Name of manufacturer Pacific Scientific c: Identifying nos. 623 N/A N/A N/A 1976 (mfr."* .naJ no.) (Nari. Bet No.J Qur!odlctlonal no.J (athefl iy.., buift) d: Construction Code ANSI B31. 7 1969 --=N~/=A.___ _ __ N/A I (ec:tftion) (addenml fCode C-(9))

6. Section XI 1983 SUmmer 83 N389 (edHlonJ ~ fCode C:-(91) 1983 S83 N/A
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made:

(edition) (.iclendaj

                                                                                                                                                                                                                   ~     Cae(llJ
8. Applicable edition of Construction qode under which repairs, modifications, or replacements were made:
  • 1977 W79 1644-6
                                                                                                                *ASME III                                            (CodeJ      (edlion)      (~
9. Design r e s p o n s i b i l i t i e s _ . F S " " " " " E . . . , . & G = - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
10. Testa conducted: hydrostatic a pneumatic c design pressure a pressure N/A psi Tenp. N/A
11. Description of work Replaryrl m1ttffl: SN #623 with snubber SN #17676

(,_ ol 9ddlional ,.,_(a) 0t -.:h(*) Is lll:Ceplable H propelly lcienllied)

12. Remarks: _ ___:..;:Wo=r.=k:.=-.,.,order==-__,#.....,:'--='9=2=09::..:1=9;,,,::0=2=6_ _ _ _ _ _ _ _--=De=f=i=*c=i=ency=..........::Repo~=rt.=;...._#::....:'--"'NOL..V=A'--------
                           ~ign Cl'laMe Package #: N/A                                                                           Rev. N/A see        attached pages for Description of Replacement.                                                                             N/A CERTIFICATE OF COMPLIANCE We certify that the statements made iri this report are correct and the repair,' modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition.

Certificate of Authorization no. 96 to use the "NR" stamp expires 7."l!t., ' , 19--*". - . Date; 1/2.f 1e.9b. Signed PSE~ Cg,-Noclear Dept. {). * (,e;t; Prilripal ED;Jr. 1 (19paif ~lonl ~~I (!Ille) CEHI FCATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure yessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwri~ MUtual In.surance Co of MA have inspected the repair, modification or replacement describe in this report on =1'1 , 19qEand state that to the beS1 of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection. bate 'f--J .11il. Sg~(. {,,?. Com.-oos A!;[}Ff[i=Y !olJtual system

                        .                                                                         (Aulhoriad Inspector)                                 (Nall.Bd.No.(indudlng et>dorsemenls)atal*    Of  province Md numbef) may be obtained from The National Board of Bot1er and Pressure Vessel Inspectors, 1055 Oupper Avenue, Columbus, OH "13229.                                                                                NB-41 Aev.6

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTAUATION OF REPLACEMENT(S) ~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PL.ANTS Page 1 of 1 Work pertor~ed by Public Service Electric & Gas a:>. - Nuclear Dept. CJP #592-200 lnMWI I-~** P 0. no. fOC no .. Mt. __Foot_ _o_f_Butta _ _nwocxi ___Road_~,_Hancccks _ _ _ _Br_1_*dge~~'-NJ _ _08_03_8_ _ _ _ _ _ _ _ _ _ _ _ _ _ _~ (llddl'WDJ

2. Owner _ _ _Pub_.;,.__l_i_c_SeIV__1_*ce __El_ectr _ _i_c_ard _ _Ga_IS_Cl:>_._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

Foot of Buttonwood Road, Hancccks Bridge, NJ 08038

                                                                                              ,_,_J
3. Name. address and identification of nuclear power plan1 Salem Nuclear Gene.rating station Unit #1 Foot of Buttanwood. Road, Hanoocks Bridge, NJ 08038
4. System Main steam Nuclear Class II
s. a Componentrepaired.modifiedorreplaced --==-===:...o...=:;...._;...=~"'-----------------------------

12MS171 Valve

b. Name of manufacturer Fisher Controls c: Identifying nos. 5725447 1112 N/A N/A 1974 (mfr.'* MriaJ no.J (Nm'I. Bd. No.J Qun.ctidional no.) (olhef) (YMT built) d: Construction Code ASME Sec. III 1971 SUmmer 1972 N/A 2 (edftion) (Code C-(9)) !Cod*Claa) 6 Section XI 1983 SUmmer 83 N/A (edttlon) (~ (Code C-(a))
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 _N~/_A_ __

(edlllon) ~ B Applicable edition of Construction Code under which repairs, modifications, or replacements were made:

  • 1971 S72
                                                                                           *ASME Sec. III                                        (Code>              (edition)  (9ddendmj
9. Design responsibilities__,PS:.=SE=&G='-----------------'------------------------
10. Tests conducted: hydrostatic D pneumatic a design pressure D pressure N/A psi 'J'ent:>. N/A **Other
11. Description of work Re!>laced stem arrl plug assembly.
 -~~~~~~~~~~~~~~
12. P.emarks: _ _Wo=r=k.=......::Ord==er:-#.._:=--=9=2=0=9=2=3=01=-4..:.__ _ _ _ _ _ _ _-=Deo.=f=i=c=iency==:;..<_-=Beto..=...:=rt-=--#~:_..;:SMD=:........;;..9=2-_3=1=5'-----

Design O'large Package #: N/A Rev. N/A See attached pages for Cescription of Replacenent. N/A

                         ** stem Inseivice Test Perfonned at OOP CEHTIFICATE OF COMPLIANCE We cenity that the statements made in this repon are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NS.102, current edition.

Certificate of Authorization no.

  • 36 to use the "NR" stamp expires ~

3 , , 19-94-. Date fl (e, 1 19,9._z Signed PSE&G eo.-Nucleaar t:Gpt (19p&Jr organizallon) Q ~u..,,{ii faulhoriz9CI ~) Principal Ergr (Ulle) CERTlFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boller and Pressure yessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwright ~ Insurance a:> of MA have inspected the repair, modification or replacement describe in this repon on ~ 19~d state that to the best of my knowledge and belief, this repair, modification or replacement has been made in aceordance with section XI of the ASME Code and the National Board rules as defined in the publication NS.102, current edition. By signing this cenificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this repon. Furthermore, neither the Inspector nor his employer shall be liable 1n any manner for any perso Injury or prop, da ge or a loss of any kind arising fromA~~~~

    .Date      f.- 7           ,1fl._Z-signed                                  Z*                                    Commissions__._M_,,__,'J........J........,7'-',_3.___________

(Nall.Bd.No.(lncluding ~I*)-* OI province Wld number)

  • may be obtained from The National Board of Bot1er and Pressure Vessel lnspeclor8, 1055 Crupper Avenue, Columbus. OH 43229. Je.a, Rrt.6

FORM NR-1 REPORT OF REPAIR ~ MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 ork perlormed by Public Ser.rice Electric & G:ls Co. - Nuclear rept. C1P #S92-202 (name) ('"!*' or9an121l110n'1 P. 0. no. roe nc ... <..

  • Foot of Butt.on'Wood Road, Hancocks Bridge, ID 08038 (ad<lrna;
2. Owner _ _ _ Pub

__ l_ic_Serv _ _i_*ce __El_ectr _ _1_*c_am _ _Gas __ eo_.- - - - - - - - - - - - - - - - - - - - - - - - (name) Foot of Butt.on'Wood Road, Hancocks Bridge, ID 08038 (addr-)

3. Name, address and identification of nuclear power plant Salem Nuclear Generatirq station Unit #1 Foot of Butt.on'Wood Road, HancoCkS Bridge, ID 08038 4 s~tem _ _ _Serv __ i_ce

__w_a_ter ____ ~==~=-=:-=-:.-----------------Nuc __l_ear __c_I_ass __I_l__ 5 a: Component r~paired, modified or replaced 12SW72 Valve b: Name of manufacturer Masoneilan -=--------------------------------------

                                      --::--::-'.:-::----:~~-----=~=-----------=-=--------~=-=-=,-------~~~---~

c: Identifying nos. N-00113-40-_2 ___N~/_A_ _ _ _ _ _ _ _N~/A ________N.,,_/_A_ _ _ _ _ _l_9_7_4_ _ __ (mfi .'s serial no.I (Nat'I. Bd. No.I ijurisdicuonal no.I (olhen (yaar buitt: d: Construction Code A.SME Sec. III 1968 Winter 1970 N/A 2 ANSI ~,7 1969 Fd. 19~..,wd. (Code Ca!e(S)i (Code Class) 6 Section XI 1983 SUmmar 83 . N/A (eCIHion) (addondllJ (Coc:le Case(S)J 7 Applicable edition of ASME Code Section XI under which repairs, modifieations; or replacements were made: 1983 583 N/A

                                                                                                                                                                                                   ~----

(lldttion) (addendaJ p:>de C.-(s)I

8. Applicable edition of Construction Code under which repairs. modifications, or replacements were made:
  • 1968 W70 N/A
                                                   *ASME Sec. III/ANSI B31. 7 1969 Fd. 1970 Add.(Coc:l*l iec:1nooni                                                              (addenda)           (CocW Case (S))
9. Design responsibilities PSE&G
                                 ----------------------===-=-----=-----=~=-~:-:--..---------
10. Tests conducted. hydrostatic D pneumatic a design pressure D pressure NOP psi Temp. N/A *Other ii. Description of work Perfonned weld repair on valve l:x:xfy.

(UM ol addttt0nal o.llMl(I) or llletch(H) is acu!>fabl* tt proper!) ~edl

12. Remarks. _ _Wo=-*_r7 k-.--Ord..,..--_er_-:'#'-:_9_1-:1_1_1;:--4_1_5=-5-=-----:-:--------------------------

r:eficiency Repc>:rt #: SMD 92-321

                         *System Insel:Vice Test Perfonnerl at NOP.

CERTlFlCATE OF COMPLIANCE We cert1ty tha1 the statements made in this repor. are correc: and the repair, modiflcat1on or repiacement oi the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NS-102, current edition. Certificate of Authorization no. Date ; 111 19,q+/-_ Signed 36 PSE&G Cn.-Nnc)ear to use the "NR" stamp expires (repai* 0<9an1zalion) r:ept. Q ..f. oct. Le lut,' J 1

                                                                                                                                                          , 19-94-.

(authorlzecs '9presenW,..) pj-jncipal (lttle) fror. CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Yessel ln§p~ctor;. and certificate of ~mpetency issued by the state or province of New Jersey and employed by Arkwright MUO.JaJ. Insurance CO of MA have inspected the repair, modification or replacement describe in this report on 5"/1 1 J * , 19~and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XJ of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal in~rty damage or a loss of any kind arising from o~~~ ~s~~ Date 7/'f ,1g'll...: Signed 4f S Commissions ,P4 l,e.f?'.. .Vt J dt J 4J~ Y:/ / (Authorized Inspector) (Natl.Bd.No.pncludin9 endOBemenls)state or province lllld number) nn may be obtained from *The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229.

FORM NR-1 REPORT OF REPAIR fl MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1

                                                                                                                                                   - Nuclear                De.pt.                        CJP #892-203 Rev. 1 08038 (name:

Foot of :&lttonwocx:l Road, Hanccx::ks Bridge, NJ 08038 (*ddresa;

3. Name. address and identification of nuclear power plam Salem Nuclear Gene.rat.in; station Unit #1 Foot of :&lttonwocx:l Road, Hancccks Bridge, NJ 08038 4 System Service Water Nuclear Class II 5 a Component repairea. modified or replaced_~l,,,,2=SW58"'-'-'=-='---V,.:-al=_,V_,e,,___ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
b. Name of manufacture 1 _ __,.Maso__,,"""",..ne-'-""1 * ,..l,.an,._.______________________________________

c IOentifying nos. N-00113-39-2 N,/A WA NL'.A 1974 (Nar: BC "-c. Uulisd1ci1onal no.) iother', iY""' buih: c Co11wuct1or* Coae A.SM£ Draft Cc:rle fo,.. Pumps & Yalves 1968 lli, l9:ZQ Add. N/A 2 ANSI BJl. 7 1969*d£d... 1970 Add. (addenda; ICoc:e '.Ase IS)i (COO~ Ciass~

6. Section XI 1983 SUmmer 83 NIA iDdiition) (aodenda: 1Cooe :::as.is);

7 Applicable editior; ol ASME Code Section XI under which repairs, modifications. or replacements were maoe: 1983 S83 N/A (..:tltooni 8 Applicabie edition of Construction Code under whicr-: repairs. modifications. or replacements were made *

                                                                                                *ASME Draft Cede for Purcps & Valves                                                            !Cod*;         1ec11toon.:    (addenoa.             (Code Case (s);

9 Design responsibilities PSE&G 1968 Ed. 1970 AdcL/ANSI B31.7

10. Tests condue1ed* hydrostatic O pneumatic D de-sign pressure 0 pressure NOP psi Terrp. N/A *Other 11 Description of work Bepl acerl va1ve bolbng ar.d r:erfonre:J weld repair on valve l:xrly.

{1..'MI ot ~.io.-..a: Viff.(11 o* sketct'l(n, 11 &c=&Ptabl* ii properf)' i0entif1~, -~~--~~~~~~~~~~~

12. =.emarks: __Wo....,_....,_r...ck.........,.Ord"-'-"~e-r~.,.j.....:_9'"'1._.J._1.._1...:4x.1...5_,__3_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

I:eficiency Rep:>rt#: SMD 92-320

                            *8Ystern In:=.ervice Test Perfomed at NOP CERTIFICATE OF COMPU.A.NCE We ~riity tr.a*, tr.e s*,ate'nents rr.aoe m this repor1 are cor,eC1 and tne repa11 modii1cat1on or rep:acemeni o; :ne items Oescr;bed above conforms to Sect1or. Xi of the ASME Code and the National Board r~les as defined in the publication NB-102. current edition.

to use the "NR" stamp expires Cct. . 19~. Cartificate of Authorization no.

                                                            .              '.36                                                                                                    3~ ,                  J Date,    1,I7                 1s._3l-signed                                      FSE&G Ce. Nuclear Ccpt.

(rep.au 019a.ru1a.lt0n) Q *.f {KA~ ~ {!!11.Jthor'ir~ re;::.rr-Arrt.a!fWJ - - - - - -(th.1~;-- - .., - CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vesse! Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by

  • Co of~have inspected the repair, modification or replacement describe in this report on - 7 , 1g and state that to the beS1 61my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Beard rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
                                                                             ~                                                                                                                  ~ Mutual System
   *Date       1 ...... vCl         .19v--signed
                                                                                        ~ '7
  • l~
                                                                                                             / /

(A~1homed Inspect()() Commissions.___ /IJ~~~L-<....,..'-------------

                                                                                                                                                                          . (Na!l.Sd.lli<>.fincluding e~menls)stale or provinc.. and numbe~

rm may be obtained from The National Board of Boiler and PresSure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 432:29. NB-81 Rev.6

FORM NA-1 REPORT OF REPAIR [ MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 3 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

                                                                                                                                                                                         ~ 1 of 1 Won     oe,..or:nec b\    Public Service Electric                               &   Gas,:*              - Nuclear Dept.                                   CJP #S92-215
  • Foot of~ :Read, Ha.JO:Cks Bri~, NJ 08038 i80Qress 2 0w~e* _ _ _Pub __l_i_c_Serv

__1_*ce __ __i_c_an::._*_Gas El_~_ectr __a:; __ . __________________________ 1r.ame Foot of ~ Road, Harcocks Bridge, NJ 08038

                                                                                                ;.oartta:

3 Name add:ess and identification 01 nuclear oower clan: Salem Nuclear Generat.irg station Unit #1 Foot of ~ Road, Hancoc:k~cs--=Br-""T""idg..---e-,~NJ~-08=0=3=s~----=-------------- 4 Sys~em O'te.rnical Volume Control Nuclea+ Class II 5 a Component 'epaired, modifieo or rep:aoec 1CV52 Valve

                                                             ~-----------------------------------~

b: Name of manufacturer Velan

                                      ~--'-.;;..;;::.-'-'------.,------------------------=c:-:-::,---------,,-~~----

c *Identityin g nos. __04_2_7_________.;N::..;,/'-'A=------ ____.=..N:.c.../=-A"----------___:;N,.L/_A _______l=9=-8.::...7.:.___ __ (mt 's oenai no.; {Illar: ~- No.1 ou~odlClional no.) jolher) d Construction Cooe west.irgho..ise E Spec. G-676241 ReV"-.-=l"-------~N,_/A~- ANSI B31. 7 1969 Ed..i~.cle70 Adi. (Coo*~(S)) (Code Clll.SS)

6. Section Xi 1983 SUrnmer 83 N/A (9dttion1 (addendm) (Cooe ~(s))

1983 N/A

i. Appiicabie edition oi ASME Code Section XI under which repairs, modifications, or r9placements were made:

(..:Inion)

                                                                                                                                                                                   -S83---

(a:!denda) 8 Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *

                                                   * *Westin#louse E Spec. G-676241 Rev. 1                                                              (Cod*i         1ec11tiotl) 9      Design responsibilities      PSE&G                                        ANSI B31. 7 1969 Ed. 1970 Add.
10. Tests condue1ed. hydrostatic Cl pneumatic[] desigr, pressure a pressure NOP psi 'I'errp. N/A *Other
11. Description of work Replaced valve disc asserrbly.
12. Remarks. _ _Wo_-_r_k~order~~-*~:_9_0_1-"-1_04-'--0_0~7_ _ _ _ _ _ _ _ _ _ Ce_f_i_c_iency_......___R_ep:>..._rt_--'#'---:_SMD __ 9_2-_3_5_1_ _ __

Cesign 01arge Package #: N/A Rev. N/A See attac..'1-ied rages for Cescription of Replacer.ent. N/A

                           *Systeln IP.service Test Perforr.ed at NOP CERTIFICATE OF COMPUANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the Natior:a: Board rules as defined in the publication NB-102, current edition.

Certificate of .l\uthorization no. to use the "NA" stamp expires Cet. 3

  • 19--94-.

36 1 Date *.Y-1 l.. 19.~ Signed PSE&G Co. -Nuclear (r*PAi* OfS&n:Z"1t0nl r:ept. __-L,,./.L,. /. *~ (*Jlto0ri21tc rt>P'H~1'.J>ll1111) Principal Erqr. (lltl*) CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure yessel Inspectors, and certificate of competency issued by the stale or province of New Jersey and employed by Arkwrl. t Mutual Insurance Co of---1.'!Vi.._have inspeclc:d the repair, modification or replacement describe in this report on ,1 and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance wi Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any person injury or property damage or a loss of any kind arising from or connected with this inspection.

                  //                                                          *            .                                                      / Jqc;t:J;>J:Y Mutual System bate         'O ,.. /3      ,199.J.-Signed                                    '                                    Commissions.~M.....::...~V.:~_,,.,.5::....1.LLZ:'--------------

(Nall.Bd.No. Qncluding endo<semenls)s1ale or province and number) rm may be obtained from The National Soard of Boiler and Pressure Vessel Inspectors~ 1055 Crupper Avenue, Columbus, OH 43229. NB*81 Rev.6

FORM NR-1 REPORT OF REPAIR fi(MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of 1

      ,     Work performed by                         Public Service Electric                                              & Gas Co.                 - Nuclear Dept.                               CJP       #S92-216
  • --=F:....:oot~::........;o::..:f::.......:Buttonwood=.::...=..;..;...;;.---Roa'-~d'--"-,_Hancocks_..:; ~---**_P_o___l"IQ_._""'_*_"°_**_..

1 1 0

2. Owner _ _~Pub--'-_l_i_c_SexV __i_oe __El_ectr __i_c_ard

____Br_i_'O:J-"'-e-'1,___NJ_ __Gas __ (_ ...,

                                                                                                                                         ....... _ _08_0_3_8     _ _ _ _ _ _ _ _ _'__

Co_._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ (nameJ Foot of Buttonwood Road, Hancocks Bri03e, NJ 08038 (add. . .)

3. Name. address and identification of nuclear power plant-=-__Sal--:--=-em __Nuc ____l_ear.....,,..=-=-Genera-=-

__t_m;_' -=-sta __ti_'_an __Uni __* _t_#_l_ _ _ _ _ __ Foot of Buttonwood Road, Hancocks Bridge, NJ 08038

4. System Steam Generator Bla...d.own Nuclear Class II 5 a* Component repaired, modified or replaced_=l=3-=G==B4o..:...-'V,;..:al=-v'-e.;;...__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

b: Name of manufacturer Masoneilan

                                                          --~~~--==="""-----------"'7::-:=--------~~-------:::--=:==---~

c:ldentifying nos. N00130-l-3 N/A N/A N/A 1972 (mlr.'s - no.) (N91'1. Bet. No.) llurlldlctioNl no.) (olhel) ~bulfl) d: Construction Code ASHE Sec.III 1971 SUmmer 1971 N/A 2 (edition) {addendal (CodeCue(I))

6. Section XI 1983 SUmmer 83 N/A (9dlllon) (addenda! (Code C-(a))
   . 7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983                                                                                       S83                N_V~A (9dlllon)       ~                 (Oocl9 ~)
  • 8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: _*__ 1971 S71 N/A
                                                                          .*ASME Sec. III/ANSI                                  B31. 7 1969                 Fd.      1970        Ad:l.     (Code)      ~111on1     !addenda!
9. Design responsibilities-=-PSE&G====-----------------------:'."""----:----=-=--=---=-~:----------

a

10. Testa conducted: hydrostatic D pneumatic D design pressure pressure NOP psi Tenp. N/A *Other
11. Description of work Replaced plug arrl stem assembly.

(.- cl addHional ~(I) or -ch(*) II acceplable f properly identlfiedl

             .___~~~~~~~~~
12. Remarks: _ __,Wo=ir:=k=-=ord=er=-~#"--':;.._::;9..:::2..;;;..0.=..;31=3:;..:1=2::....;.7_ _ _ _ _ _ _ _- - - , - - - - - - - - - - - - - - - - - - -

Deficiency Report #: SMD 92-353 See Attadmlent for Replacement *System Inservice Perfonned at NOP We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, eurrent edition. Certificate of Authorization no. 36 to use the "NR" stamp expires "'It i 1 19--94-*.

  • Date R/7 19,9k ~ned :E5E.&G Co -Nuclear D?pt (rapalr or;anizllllon)

Q _l<<,_ (aulhori2ed ~I Pruxapal Ergr. (Ille) CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure ,Vessel !n_sP;llCtOIJI, and certificate of &mpetency issued by the state or province of New Jersey and employed by Arkwright ~ Insurarx::e of MA have inspected the repair, modification or replacement describe in this report on lf;6 , 19m;;d state that to the best of my knowledge and belief, this repair, modification or replacement has been made In accordance with Section XI of the ASME Code and the National Board rulas as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be Hable in any manner for any per I Injury or property d . age or a loss of any kind arising from or conn~ ~s~ Date ~'{0 .1ffhgned Commissions~ . * (N.il.Bct.No.Qndudi"ll endotoement1)111al* or p<cMnce and numbet] rm may be obtained from The National Board of Bot1er and Pressure Vessel Npeclors, 1055 Crupper Avenue, Columbus. OH "'3229. / NEH1 Re..&

Jlq-1~'2-FORM NR-1 REPORT OF REPAIR Jd'MODIFICATION 0 OR INSTALLATION OF REPLACEMENT($) 11 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1

    • Work performed by 2.0wner_ _ _Pub __l_i_c_Serv Public Sm:vice Electric & Gas Co. - Nuclear Dept
  • Foot of Buttonwood Road, Han=:ocks Bricge, N.J

_ _ice __El_ec_tr_i_c_arxi _ _Gas (name) (llddr-) _ _Co_.________'---------------~ (name) 08038 CJP #892-218 (r.pmr cxg1111izatlon'1 P. 0. no. job. no.,etc.i Foot of Buttonwood Road, Han=:ocks Bricge, N.J 08038 (..idr.a)

3. Name, address and identification of nuclear power plant salem Nuclear Generatin;J station Unit #1 Foot of Buttonwood Road, Hancxx::ks Bridge, N.J 08038 4 . System steam Generator Blc::JWdcr.,m Nuclear Class II
s. a: Component repaired, modified or replaced __Vi_al_Vi_e __l_l_GB4 _____________________________

b: Name of manufacturer _ __;;Mas.,;;;.;;..;;sone;;;_~_..;;;i;.;;;l;....an c:ldentitying nos. N001301-1 N/A N/A N/A 1972 (mtr."s serial no.): (Nari. Bd. No.) Quri9didioMI no.) (olhGr) (yMt buib) AM.SE III 1971 N/A 2 d: Construction Code (edblon)

                                                                                     - -S71------

(addenda) (Code Cue(s))

6. Section XI 1983 SUmmer 83 N/A (9dttlon) (ed<lenclej (Code Cae(a))
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 _N.....V_A___

(edttlon) (~ ~C...(11)

a. Applicable edition of Construction Code under which repairs, modifications, or replacements were made:
  • 1911 *s11 N/A
                                              .                                                            *ASME III                                                (Cod*l       (edtticn)      (addenda)           (Code Cue(s))
9. Design responsibilities--'PSE&G~=--------------------------------------
10. Tests conducted: hydrostatic a pneumatic a design pressure a pressure *NIA psi Terp. N/A **

11 Description of work Replaced pl\XJ & seat in kind. ~---------------(uae_d_add_Hional """_'_~)_o_r_u_*ch_(*_)_i*_..:eep!able w_~_opetty __ ___ __ identllied) __________________ ~

12. Remarks: Work Order #: 920311173 Deficiency Report #: SMD 92-357
                       **system InseJ:vice Test                                       @ NOP/NO!'

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization nod 36 to use the "NR" stamp expires oet. 31

                                                                                                                                                                          , 19---94-.

Date "j- I. 19,2..Z.-Signed__;ESE....,...,:&G-.......Coi.w."""-Nl=;MO.-.l... C li.o;ea-...ir...-..Dept~-*- ....~~ca::;o:....,..-..Yo:>d?1,..&,.~!'-*--- prj nci pal (repair organizallon) (authotlz9d IWpl9Ml1lallve) ~ttle) CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure yessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwright Mlitual Insurance Co of MA have inspected the repair, modification or replacement describe in this report on 1- t z. , 19-Z3::-and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inj~rty damage or a toss of any kind arising from or connected with this inspection. Facto:cy M..Itual system Date '1 /I / CfL ,19..f.L.. Signed '\I\ J"

  • Commissions M 6 3 t".f'.Ud4/J A.J.r t£::r I (Aulhorlz9d lnapec:tcx) (Nall.Bd.No.Qncludlng endonement*)-* or province and number) is fonn may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Qupper Avenue, Columbus. OH 43229. NB-61 Rev.6

FORM NR-1 REPORT OF REP~IR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) ja TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 1 work performed b)I Public Service Electric & Gas OJ. - Nuclear Dept

  • CJ'P ts92-226
  • f----"'Foot..;......;'-'--0-f""-""-Buttonwood~-'-"-----Road-'--------'Hanax:ks=o:;__~'-=---'Br~i'-'¥'"'""""-_'-ft'--7-::....*,.;;______;;08~Q;_;3;;_8:__________1---°'-Ql9i_-_*_,.*_P_.0_._"°_*_~_*no_._*"_**_'
2. Owner _ _ _Pub __ l_i_c_Serv __i_oe __El~ectr __i_c_am __G_:;a_s_OJ __. - - - - - - - - - - - - - - - - - - - - - - - -

r....... Foot of Buttonwood Road, Hanax:ks Brid::Je, NJ 08038

3. Name. address and identification of nuclear power plant Salem Nuclear Generatin;J statioo Unit #1 Foot of Buttonwood Road, Hanax:ks Brici:Je, NJ 08038
4. System Ma.in steam Nuclear Class II 5 a: Component repairec. modified or replaced 13MS200 Orifice Flanges ~

b: Name of manufacturer M.J. J:k'&le/UE&C c: Identifying nos. N/A

  • N/A N/A -----'N,..../....,A'-=----*--1,,.,9:::..:6:::.:90---_ __

(mfr .'s IMial no.) (Nm'I. Bel. No.) (juri9dielioNJ no.) (olhef) (YNrb<rilll d: Construction Code ANSI B31.7 1969 H/1970 N/A 2 ANSI B31. l 1967 1ec1n1on) (9ddendal (Code Cue(*)) s: Section XJ 1983 SUnJner 83 N/A (ednlon) ~ (Code c-csi1

7. Applicable edition of ASME Code Section XJ under which repairs, modiftcations, or replacements were made: 1983 $83 _,,N""/c..::A""---

P:>d9 C..!lll N/A

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made:
                                                                                                         *ANSI B31.7/ANSI B31.l 1967
9. Design responsibilities~PS.....,..,E.,.&G""'----------------------------...-----------
10. Tests conducted: hydrostatic De pneumatic C design pressure C pressure 1400 psi Tenp. 780 **Other
11. Description of work aeplao;rl flarges aOO replaced boltll's.

CERTJFICATE OF COMPUANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XJ of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. to use the "NR" stamp expires ~:JY , 19---94-. 36

                                                                                 ~ Cb.-Noolea.r Dept.                                                       a .:T.&1.tvr-:Z                           Prm=~ En]r.

1 Date t/S" 19,!U, Signed (191*r ar;anizallonl (a&llhortzed ~I ) CERI FICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwri t Mutual Insurance Co of !Q. have inspected the repair, modification or replacement describe in this report on , 19 and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any per ai injury or property damage or a loss of any kind arising from or connected with this inspection. Date ~ -t:, ,111.--: Signe Commissions 11.K[J'Jfj.ocy M.ltual System (Natl.Bd.No.Qncludlng ~11111* or p<ovince and numbef)

  • may be obtained from The National Board of Bot1er and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB.81 Rrt.8

FORM NR-1 REPORT OF REPAIR [ MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) ~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l Of 1 wor~ perlormec by Public Service Electric & Gas Cc. *- Nuclear I:ept. C.,Tf #892-227 ln&me Foot of Buttonwoo:J Road, Hancocks Bridge, NJ 08038 iname Foot of Buttorrwood Road, H.ancocks Bridge, NJ 08038

ltCJO:"HI.

3 Name add:ess and identification 01 nuclear power pian: Salem Nuclear Generating s+'....atian Unit #1 Foot of Buttonwco:3 Road, Hancock.s Bridge, NJ 08038 4 System Main Steam Nuclear Class II

~     aCom~~ntrep~~d.m~m~~~~a~o-~1~~~~1_6_9_\_~_v_e                                          _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

b: "Jame of manufacturer Fisher

                                    --------------------~---------,--=--------------

c*Identitying nos. 5725441 1106 N/A N/A __1_9_7_5_ _ __ (mh *, ..,,., no.1 (Nal'. Bd No.1 Oun>d*et*ona: no.! (yaa* buih; d: Construction Code ASME Sec. III 1971 SUrrlr.er 1972 N/A 2 ANSI B31. 7 1969 E.d..:itt*cli~70 Add. 1&<:1oenda! ~ '.'.:ue(s)* IC:>de C1ass* S. Section Xl 1983 SUmmer 83 N/A

                                             \odttoan)                                               (ad~nda)                                                         (Cod* C.-(1))
7. Appli::able editior1 of ASME Code Section XI under which repairs, modifications, or r.eplacements were made: 1983 _S_8_3_ __ N/A (9dilion) l&dd~ !Cooe ::a.e1s1:
8. Applicabie edition of Construction Code under which re;>airs. modifications. or replacements were made:
  • 1971 S72 N/A
                                                                          *ASME Sec. III/                                                            (Cod*,          (odttion)                           !Cod* Case (s) I 9      Desigr. responsibilities--"-FS~E~&G~--------ANS~'__..;:;I~*_B3_1_._7_1_9_6_9_Frl                               __._1_9_7_0_Add    _ _* _ _ _ _ _ _~-------
10. Tes1s oondue1ed. hydros:atic D pneumatic a desigr> p:assure 0 pressure N/A ps: Temp. N/A **Other 11 Description of work Replaced valve bolti..""q arrl plug arrl stem assembly. Hanger rer:oved

(..- ol a<Sdiho.-.a: ..- ( * ) o: 11tetch(n) is &~eplo!>le tt ~* id&ntif..cl) to facilitate valve maintenance. Rewelded h er.

12. Remarks: Work Order f,: 920928024 Def1c1ency Rep:::>rt SMD 92-354 Design Olarge Package #: N/A Rev. N/A See attached paqes for DeSl--Yiption of Replacenent. N/A
                        ** System Inservic.e Test Performed at NOP,INOI' C8111ACATE OF COM?UANCE Cartifi:::ate of Authorization no.

Date' £)7 19.2.Z,. Si~ned 36 PSE&G Co -Ni1clear Dept to use the NR' stamp expires~ 0 a*U k

r We certify that the s1atements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section Xi o1 the ASME Code and the National Board rules as defined in the publication NB-102, current edition.

_~A

                                                                                                                                                            ,  19-94-.

Principal Engr. (**~* or;anizalion) (aut~ed r&p;"991'1'.a!Ne) (lltle) CERTIACATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure ,Vessel JnsP,ecto~. ~d CE!rtifica!e of .QOmpetency issued by the state or province of New Jersey and employed by_ _ _ _Ar __1-'gh"--t""'7'~M...,*L.,.lt:Ual<=- __kwr __JnSUranee_"'-"'l...._---U)----- of MA have inspected the repair, mooification or replacement describe in this report on ,... , 19 'and stale that to the best of my knowledge and belief, this repair, mooification or replacement has been made in accordance wit Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty. expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any perso injury or prope~ d7age or a loss of any kind arising from o~nnected ~sg,y~crern Date ~" / ) ,19g_i..Signed {. {,~ Commissions_~µ'~112-~......_,rg,.___ _ _ _ _ _ __ (Aul!.,oriz~ lnsp&C\cr) (Nall.Bd.No.pncludirog endolsements)state °' province and numbe~ may be obtained from The National Board of Boner and Pres5ure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB*81 Rav.6

FORM NR-1 REPORT OF REPAIR g; MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1

                                                                                                                                        -   Nuclear        Dept.                   CJP      #892-228 08038 2 Owner _ _-=Pub--==l=i'--'c'----'Serv~'--'-'i'--ce-'--'E'""l"""'ectr'-'--'~i=c--=an::l:=..:..:.'----"Ga.'--=s--=Co=-=-.-------------------------

{name; Foot of :&lttornvoo:i Road, Hancocks Bridge, NJ 08038 (addrHDI

3. Name. address and identification of nuclear power plant
  • Salem Nuclear Generat;irn station Unit #1 Foot of :B..rttonwcoj Road, Hancocks Bridge, NJ 08038
.; System              Seryice Water                                                                                                                                                       Nuclear Class                  II 5 aComponent~p~red.mo~fiedorre~aced_~l-3~~~~B~V~al~uv~e~------------------------------

b: Ne.me o! manufacturer _ _~M~aso=~~ne-'=... i""l.,.an ......_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ c: Identifying nos. N-00113-40-3 N/A WA NL.A 1974 (mt! 's se-na! no.) (1-<a!': 8C No.I Ounsd;cJ1onal no.) (otheri (y""* bu*": d* Co'.lstructior. Code ASME Draft cCde for Pl.IrrJt:;§ & Valves 1968 Ed. 1970 Add. N/A 2 ANSI B31. 7 1969-jiiid, 1970 Add. (eddenoa! ICo<:* ~Is); (Cod* Clo.ssj 6 Section Xl 1983 SUrnmer 83 NL.A fedrt*on) (adoeooa: 7 Applicable edition o1 ASME Code Section XI under which repairs, modifications, or replacemenls *~e~e made: 1983 S83 NL.A ledttion) (addenda) B Applicable edition of Construction Code unde: which repairs, modifications, or replacements were made: -*-- .l22a._ J.filQ_ NL.A

                                                                                                  *ASME Draft Cede for Pu:rrps & Val V~&J (edttoon;                                               (9ddend&'          (Code C&se:sJ 9      Design responsibilities FSE&G                                                                ANSI B31.7 1969 Ed. 1970 Add,.

10 Tests conduCled hydrostatic D pneumatic D design pressure 0 pressure NOP ps; Tenp. N/A *Other

11. Description of work Perfonned weld repair to valv
12. Remarks. _-L!W-""o..,,r_,_,k'--"'O""'rd-"""er,.....-__..f_._:--"'9,.l"""l.....l ...l , _ , 4 _ , . 1 " " ' 5 " " 9 - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

_ _ _ ___.Ce-= ficiency Rep:>rt ;: : SMD 92-373

     -----*~81-.....-*s_tem Inse!yice                                                     Test Performed at NOP.

CERTIACATE 01" COMPUANCE We cenity tr.at me s~a:ements maae in this ;epor: are cor;ec: a**c tne repa11. rnodif1::a11or. or rep:a::e-.em 01 t!ie items describec a::>ove conforms tc Section XI of the ASME Code and the National Soard rules as defined in the publication NB-102. currenl edition. Certificate of Authorization no. to use the 'NR" stamp expires CCt:. " , 19~. 36 3 Date 7/7 19.!/__L S;gned FSE&G Co. ~ruclear l'*O&J' or3ana1Bhon) rcpt, a*f. ~ !.&. t- {a~1~-:K representative) Princii.:'1

                                                                                                                                                                                                      .le)

En¥* CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Beard of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwright Mutual Insurance Co o!---MA.-have inspected the repair, modification or replacement describe in this report on 5',/ff. 19...ek_and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither ttie Inspector nor his employer makes any warranty. expressed or implied, concerning the repair, modification or replacement described in this repon. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal inju roperty damage or a loss of any kind arising from or connected with this inspection. Datel,£r 1 ,19 9i Signed Commissions Ab17z~~ Z'~2-¥stem 0 (Authorized lnspecior) (!'~l.Bd.No.pnciudin9 endorsoments}state or province and number) orm may be obtained from The National Board of Boiler and Pres8ure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB-81 Re-..6

FORM NR-1 REPORT OF REPAIR ~ MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 i work pertormed by Public Service Electric & Gas Co. - Nuclear Dept.. CJP #592-229 Iname Foot of Buttonwocd Road Hancocks Bri e NJ 08038 {actcrna

2. Owner _ _ _Pub_"""""l'--i_c_Serv__i_ce __El_ectr __i_c_an::l __G_oas __Co_._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

("lame; Foot of Buttonwocrl Road, Hancocks Bridge, NJ 08038 (addr-: 3 Name address and identification of nuclear power plant Sale.rn Nuclear Generati.rg station Unit #1 Foot of Buttonwocrl Road, Hancocks Bridge, NJ 08038 4 System Service Water Nuclear Class II 5 a ~mponem~p~r~.modffiedmrap~ced __1=3~~~~2-~~al~v_e~---------------------------- b: Name of manu1acturer _ _~M~la.50=-=ne=l.=*l = a n = ' - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - . , - . - - - - - c Identifying nos. N-00113-39-3 N/A N/A N/A 1971Sf ;;.J It. (m~* 's 9enal nc .. (Naf'; Bd. No.1 OuMsdicoona' ....,_ * (other; d Cons~:uction ~OE ASME Draft Ccxie for F\.mJps & Valve 1968 Ed. 1970 Add. ANSI B31. 7 1969 ,~, 1970 Add. ladoenda1 !Coo* Case(s); 6 Section*x: 1983 SUrnmer 83 N/A (adoenda; (Coo* :a..ersJ; 7 Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 N/A (edHion) (Cxleo Case(s)I

8. Applicabie edition of ~nstruc1ion ~de under which repairs. modifications. or replacements were made.
  • 1968 1970 N/A
                                                              *ASME Draft Oxle for Plmps & Valve                                                        fCod*l      1ednoon1       (addenda)        !Code Case(s)!

9 Design responsibilities PSE&G ANSI B31. 7 1969 Ed. 1970 Add. 10 Tests conducted. hydros1a1ic 0 pneumatic a desigr. pressure 0 pr<>ssure NOP psi TeI!lp. N/A

  • other
11. Description of wor~ Perto:rned weld repair on valve body.
  • --~~~~~~~~~
12. Rema~s: _ __,_,W~o~r~k._,.Ord"""-""~er---~;~:'--"9~1~1~1~1~4~1~6~1.__ __ ~~-~-~----~~---------------

Deficiency Rep;:>rt #: SMD 92-382

                        *System Inservice Test Perfonred at NOP I                                                                                CERTIACATE OF COMPUANCE We cemfy tr.at tne statements maoe .r, this repon are oorrec: ano tr.e repa1~ modii1ca11on or :e;::>lacement of the items descrioec aocve conforms to Section Xi of the ASME ~de ano trie National Soard rules as defined in the publication NB-102, cuirent edition.

Certificate of Authorization no. to use the "NR" stamp expires Oct. , 19--94-. 36 3 Date ,.7/7 19.~. Signed ffiE&G Q:),-Nuclear Cept, (repair 0<9an1za1ion1 Q ..f. -;e'Q (autl>orlze<! re.,.-.senlallve)

                                                                                                                                                                         ~
                                                                                                                                                                         - - -   - - (!~)      - - .J- -

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Soard of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwriaht Mutual Insurance Co of MA have inspected the repair, modification or replacement describe in this report on  ?'-/_ , 1~and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME ~de and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither th~ Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be lia ble ;;any mann;;r'.for any pers~ injury or pr?.~am;ge or a loss of any kind arising from o~~c;: ~~sis:~tem Date 7.~CJ ,19z.;?.*signed (_/ ~v"' *~ ~mmissions_,_/\/~1:.__.?'--2.__3'-------------

                                                     /    .                  (Authorized lnspec10l)                                     (Nall.Bd.No.Qncfudbg endorseme.,rs)s1ale        Of prov;nu and numbe~
  • may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, ~lumbus, OH 43229.

i N8-s1 Rev.6

FORM NR-1 REPORT OF REPAIR C MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S),.fl TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 Wor~ J?ublic Service Electric & Gas Co. - Nuclear Cept. CJP #S92-232 periormed by 1name .1'9P*ll ~** P 0. no. ioe no .. M<. Foot of aittonwood Road, Hancocks Bridge, NJ 08038 Foot of a..rttorr.vood Road, Hancocks Bridge, NJ 08038

3. Name address and identification of nuclear power plant Salem Nuclear Generating station Unit #1 Foot of aitt.onwocrl Road. Hancocks Bridge, NJ 08038 *
4. S)'Stem Beactor Coolant Nuclear Class I 5 a: Component repaired. modified or replaceo_.,.,1.PS.....,.""3'--'V.""al=-'v...,e=------------------------------

b: Name of manufacturer O<Pes Vulcan c:ldentifying nos. 21489-1 NjA N/A N/A __N_./_A_ _ _ __ (mil ** - no.) (Nal'I. Bel. No.1 lju'l9dictk>nlll no.J (other) (year buiHJ d: Construction Code A5ME Draft o-rle for Pl..mps & Valve 1967 F.d. 1970 Add. N/A _ _ _ _l _ _ _ __ ANSI B31. 7 1969 E:>.Ptt~70 Add. (addenda) !Cod9 Cue(s)) (Cod~ ClassJ 6 Section XJ J 983 SUrmner 83 -=N,_/A=-------------- (odttion) (l>dcSenclal (Cod* Cue(*))

7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 N_/~A___

(odttlon) (mdderod8j

8. Applicable edition of Construction Code under which repairs, modifications. or replacements were made: -*--
                         *ASME Draft Ccx:le for Pumps & Valve 1968 F.d. 1970 Add.~., coc1n1on1                                                                                 (addenda)           (Code Case(s))
9. Design responsibilities PSE&G ANSI B31. 7 1969 F.d. 1970 Add.

10 Tests conducted: hydrostatic a pneumatic o design pressure o pressure NOP psi Tenp. N/A **Other

11. Description of work Repl aced plug arrl stem assembly.

(~'H ol !lddHional lheel(sl or Sl<elch(*I is K:ei>lable M properly i0entlfi9d) CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XJ of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. 36 to use the "NR" stamp expires oet. 3 , 19--,-94--. 0ate .- JjJ/ 19.9L Signed raE&C ca.~mlear tiept. (r9i)llir C>ri&"illlionl a ...t.;f,.-1;vr.J (aulho<'.J..:I 19prnanta11119) Principal ErXJr (Ihle) CERTJFlCATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwri t Mutual Insurance Co of MA have inspected the repair, modification or replacement describe in this report on "' , 19 nd state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XJ of the ASME Code and the National Board rules as defined in L'le publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any per I injury or property damage or a loss of any kind arising from or connected with this inspection. a ./ . ,Fs~:cy Mutual System Date <j';./J,.- .1~l}- Signed "c

  • Commissions /V;i~ .

(Authorized lnspectcw) (Natl.Bd.No.Pncluding endorsomenls)-e or province and num~r) form may be obtained from The National Board al Boiler and Pressure Vessel Inspectors, 1055. Crupper Avenue, Columbus, OH 43229. NB-81 Rev.6

FORM NR-1 REPORT OF REPAIR a MODIFlCATION 0 OR INSTALUTION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS ANO SYSTEMS IN NUCLEAR POWER PLANTS Page l of l 1 wor~ pertormed by PUblic sezvice Electric & Gas Co. - Nuclear Dept . C.JP #S92-235

  • ___o_f_Butt.alWOOd

__Foot ______ ~_--',_Hancocks _____Bria:]e_*--=~';-_NJ_ 1 __ ~ 08_0_3_8_________- ____* __*._p__*""_*_/CIC_*_"°_*_*.._"_ 0

2. Owner _ _ _*PUb __l_i_*c_S&v__i_oe __El_ectri__._c_am __Gas __ ~_._1811C19U Foot of Butt.alWOOd Road, Hancocks Bri~, NJ 08038 c--1
3. Name. address and identification of nuclear power plant 5alem Nuclear Generat~ statiai unit #1 Foot of Butt.alWOOd Road, HancxX:kS Brii.lje, NJ 08038
4. System safety Injection NUCiear Class l 5 a: Component repaired. modified or replaced ll.SJ144 Valve b: Name of manufacturer
                                                           -=--=-....,--.;;._.,-...,.---::,----------------------------

Rockwell Inte.rnatiaial c: Identifying nos. N/A N/A N/A N/A 1967 (mfr .'s -i.i no.) (Nari. Bd. No.) Qurtwdlc:tional no.) (olhel) (YMr bufft) d: Construction Code PS Spec. WAPD2-<S8 ________ N/A 1 ANSI ~i7 1969 Frl. 191Qi,%j'I. (Code Cue(*))

6. Section XI 1983 SUnmer 83 N/A (lldHion) ~ ~ C-(al)
7. Applicable edition of ASME Code Section XI under which repairs. modifications, or replacements were made: 1983 S83 N/A
                                                                                                                                                                                            ~---

(lldlicnl (addendml ~ Cme(llJ

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made:
  • PS Spec WAFD2-<S8
                                                                                             *ANSI B31. 7 1969 Ekl.                           197~;:;:::;                  (addenda)      -(Code--C--(1)-J
9. Design responsibilities PSE&G
10. Testa conducted: hydro-sta~t-ic_C__p_n_e_u_m_a-tic-D--d-esi-.g-n-pr_e_ssu_re-C--p-re-ss-ur-e-,--~NO==p=---pai-.--='11=-e-1p-.-:N=-=V-:A=--=*Other=-:,-,.---------
11. Description of work Rewelded valve canc.py after valve maintenance.

(UM ol addltioneJ ~(81 at - ( * ) i9 acceplable Wpropelty id9nllliad)

-~~~~~~~~~-

1~ Rema~s: _ _Wo_:;._rk~~order,=..:...~-#~:;;..........:.9~2~04~18_0~6~7=--------------------------- Deficiency Report #: N/A

                         *System Inservice Test Perform:rl at NOP CERI FD.TE OF COMPLIANCE
     .We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as definad in the publication NB-102, current adition.

Certificate of Authorization no. 3i to use the "NA" stamp expires ~ 3 , 19-94-* Date i/J./ 19,~ Si~nad J?SE&G Cb.-Nnclear D?pt. (f9P&ir ~) a -ll~&A--1.r (9'llhollzad ~) Prirojpal (Ulla) EIW°* CEHI FlCATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pre15Ure !Jessel k'l~P1tctOtJ, and certificate of 2Pmpetency Jersey issued by the state or province of of Ml\ New and employed by have inspected the repair, modificatic>n or replacement describe in this report on rz; ' Ar'KWrl.ght Ml.Itlliil Insurance CO best of my knowledge and belief, this repair, modification or replacement has been made in accordance.with Section XI of the ASME Code and the National 19~and state that to the Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any per injury or property damage or a loss of any kind arising from or connected ~s~ Date 'fi-~ ,19fhgned ~ (Authorizlld lnspoctOI) Commissions...,..A/....__,,'.;{j~_,.o/:_~------- (Nall.Bd.No.~ncluding andocHmanl*)-* ot ptovlnce and numbef) may be obtained from The National Board of Boi1er and Pressure Vessel inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NS.ai Rev.8

FORM NR-1 REPORT OF REPAIR fj MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONE°'NTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 Wor~ & ~.::::* - pertormed by Public Service Electric Nuclear Dept. CJP :#S92-236 Foot of Buttonwood Road, Han:ocks Bridge, NJ 08038 1aoo,esa* 2 Owne* _ _ _Pl.lb __l_i_c_Serv _ _i_ce_El_ectr _ _i_*c_an:l _ _Gas __ eo_.________________________

                                                                                           '    (nain9i Foot of *Buttonwood Road, Han:ocks                                      Bridge,            NJ         08038 (adclr...;

3 Name. address and identification of nuclear power plan: Salem Nuclear Generatixq station Unit #1 Foot of Buttonwood Road, HaroX:kS Bridge, NJ 08038 4 System Safety Injection Nuclear Class 1 5 a* Component repaired. modified or replaced 14SJ17 Valve b: Name of manufacturer Rockwell International c* Identifying nos. N/A N/A N/A N/A 1969 (mlr.'s serial no./ (Nal'i. Bd No.J Qurtldiclional no.) (other) d: Construction Code ANSI B16.5 1969 N/A N/A ANSI,~. 7 1969 F.d. ~.O.J.dd. I (Code~(I)) (Code Class) 6 Section XJ 1983 SUmmer 83 N/A (adHion) (addenda) {Code C&se(ll))

7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 N/A (edHlon) (~ po Case(sj) 8 Applicable edition of Construction Code under which repairs, modifications, or replacements were made: _*_____ N/A
                                                                                             *ANSI Bl6.5 1969/                                    (Code)       (odttion) 9      Design responsibilities       PSE&G                                                    ANSI B31. 7 1969 F.d. 1970 Add.

10 Tests conducted. hydrostatic a pneumatic a design pressure a pressure NOP psi 'I'arpo N/A

  • of work Rer.Nelded valve canopy after valve ~maintenan::e.
12. Remarks: _ _ wa_rk~ord~_er_-'-#_:_9_2_04_0~6_1_8_1_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

Daficiency Report #: N/A

                        *system In.service Test Performed at                                            NOP/~eT <:-Tl-CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XJ of the ASME Code and the National Board rules as defined in the publication NB-102, current edition.

Certificate of Authorization no. Jo to use the "NA" stamp expires Oct. ) , 19--94-. a -J.fot...ur.-ir 1 Date ; Pl'/ 19,!l.1_. Signed p$E&G ()) -N!Jclear (.--Jr org&ntZa!ionJ rppt. (authorlzlOd ,.presenlal,.,,.) Prjncjpal Ea;p:. Piile) CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure YI!~ hJ§P11ctor,, and certificate of competency issued by the state or province of New Jersey and employed by Arkwr1gn"t: MUtUa.1. Ilb-urance Co of MA have inspected the repair, modification or replacement describe in this report on Z l , i912kand state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance wi1h Section XJ of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any per I injury or property damage or a loss of any kind arising from or connected w~spect~ Date fi,,/J- ,19U- Signed vi./ ~ Commissions ~'f!jry Sy (Authorizod lnspectDI) (Natl.Sd.No.Qncluding endorsomenls)llllle Of prCl'Jince and number) nn may be obtained from The National Board of Botler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NS.81 Rev.6

FORM NA-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S)j]. TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1

i. Work perlormed by Eublic Service Electric & Gas Co. - Nlx:lear Dept* CJP #592-241 (nain.) (r*o*u org&n1U1oon'1 P. 0. no. ;ob. no .. etc.I
         ~-F_oo_ot   __o_f_BUtta

_ _nwood ___ Road_~,_Hancocks~~~-Br_1_*dge--.~,_N1 __o_a_o_3_a_ _ _ _~~~-~----~~ (addrna) 2.0wner _ _ _Pub __l_i_c_Sezv _ _i_ce_El_ectr _ _1_'c_arrl _ _Gas __ Co_._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ (name) Foot of Buttorrwoo:i Road, Hancocks Bridge, N1 08038 (llddrna) 3, Name, address and identification of nuclear power plant Salem Nuclear Generatinq station unit #1 Foot of Buttorrwoo:i Road, Hancocks Bridge, N1 08038

4. System Safety Injection Nuclear Class II
5. a: Component repaired, modified or replaced_~lS=~J=3_V,~al~Vi~e~----------------------------

b: Name of manufacturer___Al=.==~~CO=-=------------------------------------- c: Identifying nos. 70A6292 N/A N/A N/A

  • _ _1_9_7_0_ _ __

(mlr.'s Mri&I no.J (Nal'L Bd. No.I Qun.diclion&J no.) (clher) d: Construction Code Westirghouse E-Spec G-67241 Rev * .::1"--=1=9=6=8_ _ _ ____;N::.;,/'-'A;.:;___ ANSI B31. 7 1969dnEd. 1970 Add. fllddendaJ (Codt>Cue(*ll (Code Class)

6. Section XI 1983 SUmmer 83 N/A (Ddrtion) (addenda) (Code Ca.se(s);
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 ~N...,/._A~--

(edttlon) (addendmj

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: -*-- ___
             *Westin:Jhouse E-Spec G-676241 Rev. 1 1968/ANSI B31. 7 1969 Fd~ fli:9i,70 <lddi.                                                                                    (llddendaJ       (Code Case(*))
9. Design responsibilities~l?S~E~&G~-------------------------------------
10. Tests conducted: hydrostatic a pneumatic a design pressure a pressure NOP psi Tenp. N/A **Other
11. Description of work Rgplaced valve bolti.rg.

(UM ol llddttion&! lhMl(I) or 1kalch(*) ii accepl&Dle K prope<fy identified)

 *--~~~~~~~~-
12. Remarks. _ _Wo'-""r.=k"'---"Ord==er=-.... #.=...:_,9"""'2""'04--=1=8-=-0=-56=.-----------=De=-=f=i=c=i=ency~"---"Rep;?-'-='-"'=rt-=-.._#"--:-"SMD='--"-9=2_-.=...39"--8.::__ __
                         !)?.sign Q1arne Package #: NIA                                                          Rev. N/A See attached pages for Description of Replacanent.                                                                       N/A
                         **SVstem Inservice Test Perfonned at NOP CERTIFICATE OF COMPLIANCE We cenity that the statements made rn this repon are correct and the repair, modification or replacement of the items described above conforms to Section XJ of the ASME Code and the National Board rules as defined in the publication NE?r102, current edition.

Certificate of Authorization no. to use the "NA" stamp expires ~~ ~ 36 Date.~£,/'? 19,?0l. Si~ned PSE~ Co.-Noclear Dept~~ P.rin:~ Engr ('90&!1 org&nizalion) (* ed ~) ) CERT1ACATE OF INSPECT10N I, the undersigned, holding a valid commission issued by The National Board of* Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey . and employed by Arkwri t Mutual Insurance Co of MA have inspected the repair, modification or replacement describe in this report on , 19f.Z:::::_and state that to the best of my knowledge and belief, this repair, modificaiion or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication N~102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any perso al injury or property damage or a loss of any kind arising from or connected with this inspection. e- / ~ ~ctocy Mutual System

   . Date _ _  {_-.L.):...:Z,~_, 19_91. Signed           .:::::1.:u::~~_.::.-e_:_:*~~~::::______                          Commissions           tJ./;;,,!J_Z 3 (Authorized lnspectot)                              . (Natl.Bd.No. Pncluding ondO<Hmonl1)stale or p<ovlnc:e and number) i J

may be obtained from The National Board of Boiler and PresSure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB-81 Rev.6

FORM NR-1 REPORT OF REPAIR ~ MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1

    ,     Work    pertormed   by J?ublic Seivioe Electric & Gas CO. - Nuclear Dept .                                                                                CJP         #592-246
  • '--_Foot
2. Owner _ _ _

o_f_Buttonwood Pub ______Rca l_i_c_sezv _ _i_ce __ El_ectr _ _ c_arrl _____Br_i?;Je__.L-'~'--NJ-_ _ d_,_,_Hancocks J._* _ _Gas __ __1 1 08_0_3_8____________' ~---*-*_P_o_.no_.job_no_ co_.________________________ 1

                                                                                                                                                                                                                            ...._c_.,

(name) Foot of Buttonwood Road, Hancocks Bridge, NJ 08038

                                                                                                     ~I
3. Name. address and identification of nuclear power plant Salem Nuclear Generatirg station Unit #1 Foot of Buttonwood Read, Hancocks Brid:Je, NJ 08038
4. System safety Injection Nuclear Class I
5. a: Component repaired, modified or replaced_-=l"-'4..,SJ=..:1=3~9:::...._-=----=--------'----------------------

b: Name of manufacturer Rc:x::k.YJell International c: Identifying nos. N/A N/A N/A N/A 1969 (mfT .'s _ . . no.) (Nm'I. Eld. No.) Qur19diclional no.) (OCher) (yMt bull!) d: Construction Code WAPD 2-CS8 --=N:.:../....,A=-=----- N/A 1 ANSI B31. 7 1969 :Ecidttklle70 Add. 18ddendml (Code Cue(*))

6. Section XI 1983 SUmmer 83 N/A (edition) (~ (Code C-(1))
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 $83 .;;,.N..._/""A;;,,.___

(9dlllon) (~

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *
                                                          *WAPO 2~/ANSI B31. 7 1969 Fd. 1970 Mi.                                                          (Code)       1ec1tt1on)      lllddendal         . (Code Case(*))
9. Design responsibilities__..PSE&G"""°'..,..""'--------------------:---------...-----:-:c---------
10. Testa conducted: hydrostatic C
  • pneumatic C design pressure C pressure N/A psi Tertp. N/A **Other
11. Description of work Rewelded valve ~. after valve inspection.

(UM ol addllional ~(1) I)( -ch(..) is IOCcepCallie ff properly ldenlllled)

-~~~~~~~~~-
12. Remarks: _ _,Wo=ir.=k.......:Order==--'#L.::-=92=0=3=2:...:.7-=12,.._8'7'-------=-----:-::De=:=:f=-=i::.:::c::::i::::ency=L....-::Repo==rt=--.!#!....::c.......=..:N/L.:A:.=--_ _ _ _ __

resign Owse Package #: N/A Rev. N/A See attadled pages for Description of Replacement. N/A cemACATE OF COMPUANCE We certify that the statements made in this report are correct and the repair, modification*or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. 36 to use the "NR" stamp expire~ ~*t:a , 19---94-. Date 1/5' 19,C/2. Signed :i::sE&G eo.-Nucleetr eept. (MPai* otganizatlon) {2 /. o {aUtho<ized ,.p<eMf11&1hM) PrirripaJ ED]r. (lllle) CERT1F1CATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure yessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwright ~ ~ Co of m have inspected the repair, modification or replacement describe in this report on f~. 198ndState that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, eJCpressect or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection. Date f' ( ,1lfk'§1gne t{,

                                                                                   !Authorized lnepectOI)

Commissions JVJ2}!fj?:Y Mutual System (Nall.Sd.No.~ndudlng *ndo<Mm911te)llal* or p10Yince and number) .

  • may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, ~ 43229.

Ns-a1 Rev.6

FORM NR-1 REPORT OF REPAIR ~ MODIFICATION Q OR INSTALLATION OF REPLACEMENT(Sl C TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PL.ANTS Page 1 of ' Wor> oer.ormec oy Public Service Electric & Gas Co. - Nuclear ~* 1r-.arne

  • Foot of ButtoP.WClCC. Road, Hancocks Bridge, NJ 08038
aoc*"5S*

1;-.ame. Foot of Buttonwcx::C Road, Hano:cks Bridge, NJ 0.8038

                                                                                                                             \atSd~esa;
     .:1      Name address anc identif;car*o,., of nuclear power plant                                               Salem Nuclear Ge."1:ratirg station                                                          Unit #1 Foot of ButtorrWOCX: Road, Hancccks Bridge, NJ                                                                               08038
     < Systerr              Safety Inje...-tion                                                                                                                                                                   Nuclear Class I 5 a Comoonen:~c~rec.modif~~re~a~c~~l~2~~~1:4~4~V~~~v~e~----------------------------

o "iame oi manufacturer Rockwell International

c. identifying nos. _ _:cN""/-=-A=------ ------'N'-"'--'A'-"------

1 NIA NLA 1969 {mti 'i seroa: no.; ~at'i. Be' No.I ~uosdic:oO<".a: no.J {oth*I"! ~Boa.* buitt: d Construction Code Westi..T'):lhouse_§pef G-676241 NLA 1 ANSI B31. 7 1969 Bl.a~.~70 Add. fadde~dai ~c.Me(SJ) ~:;:ass~ 6 Section XI 1983 SUmmer 83 NLA

                                                    ;ed~ionr                                                                    (sooe"daj                                                                   (Code Cese(1))

7 Applicable edition of ASME Code Section XI under which repairs, modifications, or repla~ments were made: 1983 S83 _N~/_A ___ (edHion) 8 Applicable edition o1 Construction Code under which repairs, modifications, or replacements were made: *

                                                                                                   *Westinghcuse Spec                            G-676241/                                tcod*l           (odttion)    (addenda)           (Cod* Cese i*J:

9  !)esign responsibilities PSE&G ANSI B31. 7 1969 F.d. 1970 Add. 10 Tests condue1ed. hydroS1atic O pneumatic O design pressure[] pressure N/A psi Tenp. N/A **Other 11 :iescription of work Replaced valve canopy by welding. (~.,.. :>I sdd~""'4: >1'...,1(1) or sk.,ch(eo: is acoep:~ ~ ?'"P"rfy idanllfied)

   , 2.      Remarks: __w~*o=r=k'-'--'O=rd:..=:er=-_:!:"-;;_:__,9:....:0::..::0:....:7-=2=5:...::0=8=3_ _ _ _ _ _ _ _ _--=De=-=f:..::i:...::cc..=i:...::erg=.:::.~.::..cRec:;.po"-..:Crt=--=--#"--'--:--=N~/--=A-=---------
                             ~ign ~'Ee Package                                                        f:   N/A                             Rev. N/A see     attached paqes for Cescription of Replacerrent.                                                                                               N/A
                              **  System I.nservice Test Perforried at NOPjNOI' CERTIACATE OF COMPLIANCE We certify that the statements made in this report are correci and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the Nat;onal Beard rules as defined in the publication NS-102, current edition.

Certificate Of Authorization no.

  • 36 to use the "NR" stamp expires Oct~, , 19-94-.

Date ;j_/_!J-_19,U. Signed FSE&G eo.-Nuclear Cept (r~' "';ani2alion) Q .j ellf.A.. /r (a<Jlhor'.>ed ,.,,.....nta!"'9) Princip=il

                                                                                                                                                                                                                           ~Hie)

Erw* CERTJACATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Boe.rd of Boiler and Pressure ,Vessel Inspectors, and certifiv.ite of competency issued by the state or province of New Jersey and employed by Arkwrl t Mt.itual Insurance Co of MA have inspecied the repair, modification or replacement describe in this report on - , 19-Rand s~ate that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance wit Section XI of the ASME Code and the National Board rules as defined in the publication NS-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any pe I injury or property da age or a loss of any kind arising from or connected with this insl)ection.

c. / z c:; .C' / _ ~P-<;;t;.or:y Mutual System
         *oate      (}" / /         , 1~ Z:      Signe                                                           *       -y-'1....--'                   Commissions_,,V:<....L.C.._'J.L...__....__.*TS (Autt>orized lnspeelotj                                      (Natl.Bd.No.Qncluding ondorsemenls)stale or provinu and numt>eq rm may be obtained from The, National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229.                                                                                                   NB-81 Re-.-.6

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S),!I TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1

     . Work performed by                PUblic Service Electric & Gas Co. - Nuclear Dept.                                                                                   CJP #592-254 (name)                                                      (1'9pair organization's P. 0. no. job. no.,etc.)
  • Foot of Buttonwood Road, Hancocks Bridge, NJ 08038
                                                        '                                                       (.iddresl)
2. Owner_ _ _Pub~,;;_l-...:1:;;_*c__;;Serv~-'--i_;ce~-El~ectr...,;;_;.=i-""c_arxi="'--Ga=-s.:.__Co;_..::....:._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

(name) Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 (eddrea)

3. Name, address and identification of nuclear power plant Salem Nuclear Generatirg station Unit #1 Foot of Buttonwood Road, Hancocks Brid::Je, NJ 08038
4. System safety Injecticm Nuclear Class I
5. a: Component repaired, modified or replaced _ __,.,l.,,l,.,.S""'J..,3""'4'--"Vi-=al=-"vc.:::e:......=Bo=l::..:t=ioo=----------------------

b: Neme of manufacturer Allied Nut & Bolt Co. c: Identifying nos. N/A N/A _ _ __,,N;.,_./A,..________-=N#--'/A.....__ _ _ ._--=N-/=A,,__ __ (mlr.'s serial no.) (Nm'I. Bet No.) Qurladictlonal no.) (other) (yearbulH) d: Construction Code ASHE Sec*. III 1977 SUnmer 1982 N/A 1 ANSI ~lo 7 1969 F.cl. l~Adj,. * (Code Cale(s))

6. Section XI 1983 SUmmer 83 N/A (mdHlon) (eddendm) (Code C...(91)
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 583 N/A (mdHlon) (~ Pldl c-{11)
8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: * ...J.9Il .saL N/A
                                                                                            *ASME sec. III/ANSI B31. 7                                                       (mdHlon)                           (Code Cue(*))
9. Design responsibilities PSE&G 1969 Fd. 1970 Add,.
10. Testa conducted: hydrostatic a pneumatic a design pressure a pressure tl)p psi Terp. N/A *
11. Description of work Repl ary:rl ya1ve holtin;;J.

CERTIACATE of COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section Xi of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. to use the "NA" stamp expires Oct. J , 19--94'. 36 1 Date f-/, 199'2.... Signed ~ Cea-Nuolea:r Dept *.~ L,,4* PrinJ~ ERg:r. (~r organlztlllon) (auttiorlzmd ~) CERTlFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by

  • Arkwright ~ Insuran:e Co of MA have inspected the repair, modification or replacement describe in this report onr_;:z,: 1~and state that to the beat of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any perso I injury or prOJ?erty mage or a loss of any kind arising from or connected with this inspection.

Date tf-12 ,19'i_[ Signed Commissions A!:1'f7Try MubJal ~ (Nall.Bd.Ho.(lncluctlng endorMments)sllll* or provinee lllld number) form may be obtained from The National Board of Boiler and Pr8ssure Vessel lnspeclonl, 1055 Crupper Avenue, Columbus., OH 43229. NB-61 Rev.6

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) gJ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 Work performed by Public Sel:vice Electric & Gas Co. - Nuclear Dept. CJP :f591-256

*                                                                                                    (name)                                                           ~ ~*1                P. 0. no. po. no.,etc.)

Foot of Buttonwood Road, Hancodcs Bridge, NJ 08038 (addrwu)

2. Owner _ _ _Pub __l_i_c_Sel:v _ _i_ce __ El_ectr

__i_'c_ard _ _Gas _ _Co_._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ (name) Foot of Buttonwood Road, Hancodcs Bridge, NJ 08038

3. Name. address and identification of nuclear power plant Salem Nuclear Generatin3' statiai Unit fl Foot of Buttonwood Road, Han:xX"kS Bridge, NJ 08038
4. System Chemical Volume Control Nli::lea.r Class 1
   ~~~mpoMmre~red,modmedmrep~ced~_l_~---~--~-----------------------------

b: Name of manufacturer Cope VUlcan c: Identifying nos. 691095001-58-3 N/A N/A N/A 1968 (mfr.'s serial no.) (Nal'I. Bd. No.) (juri9dictional no.) (alhet1 d: ~nstruction ~de ASME Draft Ccxie for Pun:ps & Valves __ 19_6_8_F.d_._1_9_7_0_1d:l __*__ ANSI ~iln, 7 1969 F.d. 19;l.Qe~. (Code CW(slt

6. Section XI . 1983 SUimer 83 H/A (edHlon) (lllddendmj (Cam : - a i l
7. Applicable edition of ASME ~de Section XI under. which repairs, modifications, or replacements were made: 1983 S83 N/A (edilian)  :-.mi om CIDelrll
8. Applicable editio.n of ~nstruction ~de under which repairs. modifications, or replacements were made: _*__ 1968 1970 N/A 9 Design responsibilities PSE&G *~ ~ ~9 m: ~J>&:ralves/ '!'alp. NOP Cade)

N/A + fedb>n

                                                                                                                                                                          ~
                                                                                                                                                                                 ~
10. Tests conducted: hydros~a~'Wt{;le ~re C pressure psi Description of work *

(UM ol addition& ~) Of -ch(*) ii a=iplablo H properly identified) Werk omer #: 910419133 DefieiencJY B:port '#: H/A l2. Rema~s:_-EDes~~ie~1H-0l~'lilla-H~aee---,PaflajeleKJ~~g~e~#~:~N~/~A~---~R~!eeY-¥0 .~~~9~~A~----------------- See attached pages for D:seription of ReplaOC!liel'lt. N/A

                           *SJtsU:m Inse:rviee Pefi-oBEd at NOP CBrnACATE OF COMPLIANCE We certify that the statements made in this report are corre:t and the re~r. modification or replacement of !tie items de::nbed above confomls to Section XI of the ASME ~de and the National Board rule& as defined in the publication NB-102, current edition.

Certificate of Authorization no.

  • 36 to use the "NA" stamp expires oct. 3' , 1g 94.

Date 7- I :L. 19,.L;L_ Signed PSE&G Co. -Nuclear Dept. L4 &: , -4* _ Frin::ipal Ergr.

                                                                                 .~organizalion)                                     (authorized '*P'Wllldiwl                       (1111)

CEmlACATE OF INSPECTION l, the undersigned, holding a valid commi~~e National Board of Boiler and ~f- ~aw~ ~ncy issue~ the state or province of  : and employed by >> of have inspected the repair, modification or replacement describe in this report on $"-' , 1E'-f l.~ state that to the best of my knowledge and belief, this repair, modification er. replacement has been made in accordance with Section XI of tte .A.Si.IE Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his tmpjoyer makes any warranty, expressed or implied, concerning the repair, modification nr replacement described in this report. Furthermore, neither tte ~r nor his employer shall be liable in any manner for any personal injury or prcperty damage or a loss of any kind arising from ~ ~iJ:i!s~ Date Y., I Z ,19'Jl- Signed ~ fZa.,v,/ ~~ {~ flulhorized lnspec1cx)

                                                                                                                          ~mmissions-'-Af-r=_.........__...?_1.....3"'-----------

(Natl.Bd.No.jnduding ec oduc&111"' '1!11:- ot p<oWice and runbol) This form may be obtained from The National Board of Boler Wld Pressure Vessel Inspectors, 1055 Crupper lllenue, Colunbus. OH 43229. NB-81 R.v.6

FORM NR-~ REPORT OF REPAIR C MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) '5 TO NUCLE.AR COMPONENTS AND SYSTEMS IN NUCLE.AR POWER PL.ANTS Page l of 1 Vv*:n  :.e~or:r.ec ::;-. Public Service Electric & Gas Co. - Nuclear r:ept.. CJP ~S92-264

  • Foot of :aitto."'?WOCXl Road, Han::o::ks Brio;e, NJ 08038
                                                                                                       *~=*ess 2 ~*..,e* ___Rm      __l_i_c_Serv      _ _i_oe      __El_._ect.r

_ _i_c_aro _ _Gas __ eo Fo::>t of ~ Road, Harco::ks Bridge, NJ 08038

aoc-..

3 Nar.ie ado~ess anc 1oent1f1::at1on of nuc!ea* powe* p1an: Salern Nuclear Generating station unit #1 Foot of Buttorrwooj Road, Han::ccks Bridge, N7 08038 4 Ststerr. _ _ _Rea __ ct.o __ r_Coo __l_an_t__-..-::-:---:::-:-----:::----"T--------------Nuc _ _l_ear __c_l_ass __l__ 5 a Component re::::arrec modified o~ rep:a~ #11 Stearn Generator

                                                                 .,.----'---=-=-----;-.---:::----~-r------------------------

C. ";arr.e o~ rnanu!a::::tu*e* Westin;Jhcose Electric Corp:>ration

c. tdentitying nos 1003 68-10 N/A N/A 1970 imf'o 's ,.,~, no.i (Nat'; Bd. ~-i Curitdictional no.) (other) (year buihl d: Construction Code ASHE III 1965 SUmmer 66 N/A 1 (edhoon1 !Code Cbe(s)I (CoCJe Class!

6 Section XI 1983 SUmmer 83 N/A (.c1Hoon1 -nda) (Code C-(1)) 7 Applicable edition o~ ASME Code Section XI under which repairs, modifications. or replacements were made: 1983 S83 N/A (.ci~ion)

a. Appiicable edition of Construction Code unde: which repairs, modifications, or.replacements were made:
  • 1965
                                                                                                  *ASME III                                                   (Cod*)                                     (Cc.de '.:.ase(SI)
9. Design responsibifit1es_PSE __ &G__________________7=--=-----=----=-::-:-:=--~----------

10 Tests conducted hydrostatic 0 pneumatic Cl design p;essure a pressure N/A psi Temp. N/A ** 11 Description o! work Replaced heliooil in bol thole #1

12. Remarks. Work Order ~: 911014107 I"ef iciency Report #: ISI 92-437 resign C".arl3e Package #: N/A Rev. N/A See attac.11ed pages for D:scription of Replacer.ent. N/A
                           **    System Ir.servioe Test @ NOP/NOI' CERTIFICATE OF COMPLIANCE We certify that the s:atements made in th;s report are correci and the rep.air, modification or replacement of the items desc:'.bed above conforms to Section XI of the ASME Code and the Nationa: Board rules as defined in tl'1e publication NS-102, current edition.

Certificate of Authorization no. 36 to use the "NR" stamp expires Oct  !' , 19--94-* Date; RJi 19,~. Signed FSE&G Co -N11cJ ear I"Ppt (repair ot;ianizalionJ a J~l!!.A<i (authoriJ.ci r*?*"Hentaliwl Principal (l~l*)

                                                                                                                                                                                                    ~-

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pre~sure Y~sel l.fl~p~ctor~. l\!)d certificate of 1<,ompetency issued by the state or province of of *MA New Jersey and employed by have inspected the repair, modification or replacement describe in this report on r.z; , Ar'.KWTl.gnt MU'Olal. l..r'.surance CO best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XJ of the ASME Code and the National 19£..l:ijfi;d state that to the Board rules as defined in the publication NS-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be ~le in any manner for any pers injury or prop~ d/ag: or a loss of any kind arising from o~~cy ~s~~f'em Date "-f - /J ,19f ksigned lz' ~ (Auttiorized lnspectorj Commissions ~l 7J (Nall.Bd.No.Qncluding endoraemen!s)state or province and numC..~ onn may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Qupper Avenue, Columbus, OH 43229. NB-81 Rev.6

FORM P\=1-1 REPORT OF PEPAIR 0 MODIFICATION 0 OR INSTAUATIO" J= REPLACEMENT($)~ TO NUCLEAR CCM?ONENTS AND SYSTEMS IN NUCLEAR POWE= ::i;,.ANTS Page 1 of 1 oril perlormed ='! PUblic Sezv:be Electric & Gas Co. - Nuclear Dept. CJP #592-269

 *                                                                                           *                 (name)                                                             (repa.u org.an.z:mc:r  5 P. O. no. job. no.,etc..:

Foot of ts..rt:tonwood RoaC.. 3ancocks Bridge, NJ 08038 (address) 2.0wner _ _ _PUb __l:._"_c_Serv _ _i_ce_El __ e_:_::::::___*c_arrl _ _Gas _ _Co_._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _~ (name) Foot. of aittonwood RoaC., Sancocks Bridge, NJ 08038 (addrosa)

3. Name, address anc centification of nuc:learx-: plant Foot of Il.Ittonwood 'Rl:laC,. Ean::ocks Bridge, NJ 08038 Salem Nuclear Generatirr; s:a--.ion Unit *1
4. s~em Safety Injection Nuclear Class 1
5. a: Component repai~. modified or replacec  !..l.SJ55 ValV'e
                                                                        -=--~---------------------------------~

b: Name of manuta::-..Jrer Ancnor :E=lin;J c: iaentitying nos. N/A ____ N._/A __________ N._/_A_ _ _ _ _ _N_-_.A _ _ _ _,_ _1_9_8_8_ _ __

mfr.'s serial no.) ,_.., 3d. No.1 ijurildiclional no.) ClfTmr; (yaar buih) d: Construction Coo: West~ Spec 67-6241 N/A 1 ANSI ~Jn. 7 :39 E:i. 19ilQ,,, Atid. (Code Class)
6. Section XI 1983 SUmmer 83 ledrtion) (addenda) (Code Case1s
7. Apolicable edition:- .l..SME Code Section X _r~r which repa::-s :-iodifications, or replacements were ma:H:  :.983 S83 N/A tedttlon) (Code Ca9e(sjJ
8. Apclicable edition er :Anstruction Code un:er ¥1"1ich repairs. moe-<ications, or replacements were mace: _*__ N/A
                                                                                                *Westin;Jhouse Spec 67-6241/ .:..xm (edrtionl                                                                       (Code Case (s))
9. Design responsibi:-:es PSE&G ~I B31. 7 1969 E:i. 1970 Adi.
10. Tests conducted: '.°"*l:Jrostatic a pneummc: design press..:-e a pressure NOP psi Te!D;- ~'/A *Other Description of w:r. Replaced v-C:.:....,-e boltin; *
                                                                         ..- :r addrtional she<<$ :r -ch(es) is acceptable ~ property identifoed)
12. Remarks: ----:::Wc:k,--...,----Ord-=:er--'#'-:---:::9:-2_C'-::-'--~-_~_06_2,,,_-:-::--=-------:::,---~De=-f_i_*c_1_*ercy _ _.,__:re:_,:=-*-:>rt __#_:_SMD __ 9_2_-4_5_3_ _ __

D:sign Oiarqe Package #: N/A Rev. N/A See attadled fA39CS ::-or ~ion of Replacement. N, :1

                              *S:"Stem Inservicc -:est Perfon:ed at OOP/r.JoT                                                            oJg, CERTA:ATE OF COMPLIANCE We certify that the szements made in ttiis 'f!:C* are correct a"lC ":""1e repair, modification or replaceme~! o* tie TIBms described a.:iove conforms to Seeton XI of the ASl\E Code and the Nat1or<11 :Oard rules as def::'ed in the publication NB-102, curren: edi1cr.

Certr.lcate of Author:::::ion no.

  • to ..ose ttle "NA" stamp expires Oct. , 19----94.

36 3 Oat~ f/S :9,qi.. Signed :sE?cG Co.-Nirlear rept (r_, ::r,an:za1ion) a .j/(c l../.-4 (authon2ec: ~I Prircip.31 Erqr. 1ttt** CEA IFCATE OF INSPECTION I, the undersigned, h:iding a valid commiss~:r _ssJed by The National, Board of Boiler and Pressure yesse nsc~~j and ce!'lffio::te of competency issued by the state er province of N5i Jersey anc employed by Arkwright~ lnsura"'X:e Co of MA have nspected the repair. m:cification or replacenent describe in this report on ' *~ , 19?/.Lard state that to the best o1 my knowledgt and belief, this repair. nccitio::ation or repl!ICe!"""lent has been made in accordance wTth Stc:icr. XI of the ASME ::.Ode and the National Boan:I rules as define: 1n the publication NS.**~ ::urrent editior. :fy signing this certificate, neither the lnS;>tCn:r nor his employer '.T'lakes any warranty. 4 expressed or impliec :oncerning the repair. rcciification or repia.:ement described in this report. Furtnerrmre -reither the lnspe=r nor his employer shall ce liable in any ~anner for any ~na r!U:Y or property c:ar.iage or a loss of any kirid arising from o :::rmected with eiis 'r.spection. Date

                   ,y . /
                   "tc-lL
                                       .19'1..k.. Signe~~./ l,.. ~

c* / , &.-<"Factory Mutual System Commissions_lv--'-..L,.__.:..*:_,,,-_*"")_ _ _ _ _ _ _ _ _ _ _ __ (Author::.c: nspecio~ (Nall.6'::...'<c.ncw:img endorsements- :n province and numbe~ This fcnn may be obt!ined from The Nationa :amt! of Boller and Pfess.ure Vessel Inspectors, 1055 Crupper '¥er.Ille, Columbus, CJ-l 43229. NB-81 Rev.6

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) (?' TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 work  :::ienormed b~ Public Service Electric & Gas Co. - Nuclear Dept. CJP #592-270

                                                                                                       !name.                                                           11'9PAJ* ~** P O nc ,oc. nc .... c.
  • Foot of aitt..anw'OCXi Road, Harnx:ks Br~, NJ 08038
.adorns 2 Owne* _ _ _ __l_i_c_Seiv Pub _ _i_*ce __El_ectri _ _._c_arrl __Gas __ eo (name*

Foot of SJttonwocxi Road, Harnx:ks BriO;Je, NJ 08038 (Ml<lrm. 3 Name address and identification of nuclear power plant Salem Nuclear Generatin3 statia'l Unit #1 Foot of SJttonwocxi Road, Harnx:ks Bri(lje, NJ 08038 4 Systerr _ _ _Rea __cto__r_OX> __l_ant ____n-:--~=---.,~----,r---------------NUC __l_ear__Cl_ass __l_ _ s a*Com~nem~p~red.modffi~~rep~~~~#_1_4~~~-~~~-~-~~r~~~~-------------------~

b. Name o1 manufacturer Westi.rqlalse Electric Corporation c* Identifying nos 1203 68-51 N/A N/A 1971 (mfr '* Nnal no.) (Neri. Bel. No.; Oun.dictional no.) (olhefl {yMS buil!)

d* Construction Code ASME III 1965 SUnmar 1966 N/A 1 (9dffion) !Code Case (1)) 6 Section XI 1983 Summer 83 N/A

                                                                                                                                                                       !Code Cue(1))

7 (9dffion) (addende) Applicable edition of ASME Code Section XI under whict. repairs, modifications, or replacements were made: 1983 S83 _..... N/A ___ (edition) (addendeJ pm Cl!e(llJ a Applicable edition of Construction Code under which repairs, modifications. or.replacements were made:

  • 1965 S66 N/A
                                                                                                *ASME III                                                !Code!       (edllion)                         (Code C.-(1))
9. Clesign responsibilities.--=PSE&G~=--=-------------------::-=--=----=----,,.,,.-=---,~---------
10. Tests conducted. hydrostatic a pneumatic a design pressure a pressure N/A psi Terrpo N/A **
11. Description of work Replaced primary manway boltirx3 on #14 steam ~tor hot leg.

IUM d llddffiol".a! .,._(*) °' -ch(n) is ace&plable K pt0perly identJlied} Work Order "": 920129133

12. Re ma rk s.~~-:.....,.:.-=--,.-----'w'-'---~--,,.-----,,.-------------=,,---=,_,,,.------'~~-~,,__._:;__ J:eficiency 'Dol'V'\rt #: !SI 92-456

_ _ _~~~---~ Design O?arge Package #: N/A Rev. N/A See attached pages for tescription of Replacement. N/A

                             ** System Inseivice Test @NOP/NC1I' CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition.

Certificate of Authorization no. Jf; to use the "NA' stamp expires :n 1

                                                                                                                                                               , 19-94-.

Date ; j/J 19,92. Signed psE&G en. -Nuclear D?pt. (..._, <><ganizallon} a*~ lrt.'-.'ft (authotlz.O  :.~) Pcincipal Ergr. (ll!Ja) CERTIFICATE OF INSPECTION I, t~e undersigned, holding a valid commission issued by The National Board of Boiler and Preisure .V~sel !fl_sp,ecto~. 40d certificate of ~mpetency issued by the state or province of New Jersey and employed by Ar'.KWTJ.gnt Ml.Itlla.1. .ll'lSUraI're <.:o

  • of MA have inspected the repair, modification or replacement describe in this report on ~ b , 19£:Z:and state that to the best of my knowledge and belief, this repair, modification or r9pla~ment has beeri made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be ~~e/i~ any man~r for any perso injury or prope~am;e or a loss of any kind arising from oFa~cy ~s~

Date Q_ I-- ,19z_.J Signed Z

  • l-tr Commissions.--'N---'-~=--IOC..J_2..,,~,,,,.3:......_ _ _ _ _ _ _ __

(Aulhori.?ed lnspec10f) (Nall.Bd.No.ftneluding endonem*nls)llllfe °'province and numbe!I orm may be obtained from The National Board of Boner and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NS.81 Rev.6

FORM NR-i REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) ~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 or~ Gas,:* CJP oertormed tiy Public Service Electric & - Nuclear Dept. #S92-272 Foot of Butto~ Road, Hancocks Bri~e, NJ 08038 2 0wl'"ler _ _ _Pub __l_i_c_Se.rv __1_*oe __El_ectr __i_c_am __Gas ___ eo_.__________________________ 1name; Foot of Butt.or'llNoa:i Road, Hancocks Bridge, NJ 08038 (lldClr-J 3 Name address and identification of nuclear power plant Salem Nuclear Generatin;; station Unit #1 Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 4 S)'Stem Safety Injection Nuclear Class I 5 a* Component repaired. modified or replaced 13SJ56 Valve

                                                                   --=-=~'-"--=---'-==---"--;-~-------------------------

b: Name of manufacturer Anchor tarlin::J for Westin:IDouse c: Identifying nos. 11542-10-40-PSE-10C48Z N/A N/A N/A 1974 (mh.'sMOaJno.J ~- 9d.~.1 ijuriadlclional no.) (alhel) (yMr buih) d: Construction Code ASME III 1971 -~W.J,/_7~1~---- N/A I (9dhoon) (addenda) !Code ease rsn

6. Section XI 1983 SUmr.er 83 N/A

(..:lhion) (lllddendmj (Cod* Cue(*)) 7 Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 ___ N~/.._A (9dhlon) 8 Applicable edition of Construction Code under which repairs, modifications, or replacements were made:

  • 1971
                                                                                                      *ASME III                                                 (Cod*J       (ednionJ                        (Code Case(*))

9 Design responsibilities~PS~E~&G~-------------------------------------- 10 Tests conducted. hydrostatic 0 pneumatic a design pressure 0 pressure N/A psi Tenp. N/A ** 1i Description of work Replaced valve bolting ard seal plate. 12: Remarks: --'Wo-'-=r=k=---"Ord=er---=--_...#"-':'--"'9-"'2""""0-"-5-'-3=10""'"0~3":---_ _ _ _ _ _ _ _ _--:-:-cD:c:::-f_ic_1_*ency _____Rep? ___ rt_#"--:_SMD __ 92_-_4_6_2_ _ __ resign Cl"lan:1e Package #: N/A Rev. N/A See attached pages for Description of Replacement. N/A

                       **    System In.service 'Test Perfomed at NOPjNCII' CERTIFICATE OF COMPUANCE We certify that the statements made in this repo~ are correct and the repair, modification or replacement of the items described above conforms to Section Xl of the ASME Code and the National Board rules as defined in the publication NB-102, current edition.

Ceo1ificate of Authorization no. to use the 'NR" stamp expires ~* , 19-94-. 36 31 Date P/5 19,!12 Signed PSE&G Co.-Nl.lclear Dept (repair Ofiar>lalion) a .. Rc'tvri (AIJ!hor'2rod ,.p,....n:a!i...) Rrioci~J (ll!Je) Engr. CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure .Vessel lnsP,ectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwright Mlltual Insurance Co. of MA have inspected the repair, modification or replacement describe in this report on y . . z; , 19 z, Vand state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as define<;! in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer - - - shall be liable in any manner for any person injury or property damage or a loss of any kind arising from or connected with this inspection.

                                                                                               /                                                             p~:ry                 Mutual System Date       f-- I/           'rnf1.~Signed
  • l .-r Commissions_M__,-;JJIL-.-<:-D.2 (Nell.Sd.No.Qncluding
                                                                                                                                                                            *~menla)slal*       or province and numbet) rm may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229.                                                                            NB-81 Re..6

FORM NR-1 REPORT OF REPAIR TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of

                                                                                                            =       UOOIFICATION :J OR INSTALLATION OF REPLACEMENT(S) )21 2
*"'~rk           performed by __J?!c:.u1h...,,,.,J_.i....                          ce""""~E c-.....A.Se.,.*...,nr'-"-1.LJ'          .....l ...ectri-....
                                                                                                                    * -__.i..._C:._.-a......,s._._c...                                     r__.De~pt~
o.....__-_Nl....,..1..,c....1..,e...e...

(011"'1e)

                                                                                                                                                                                                           .....--__,,CJP    .......__#IDS..,_9£2--_..2.,,8~0'---------

(repair organization's:> C -io., job. no.,etc.) Foot of Buttonwocrl Rood, Haoca:ks Br"idge, tU 08038 (ac:iress) (r"ZT!e) Foot of 8Jttonwocrl Roa.d, Hancocks Bd.c%1e, NJ 08038 (ao::rress)

     ;_ ""'me, address CWlc! identification of nuclear power plant _ __.sa                                                                                                                 .......t...,,.,in]"""'='--"'sta'-"""'...,t"'i"'on......__Uni~~*~t'---lji...1~-----
                                                                                                                            ........1.,.em.....__.Nuc.,,,...l...ea....,...r__,,,Genera""""..,,...

Fmt of B Jttarn.axrl Rrad, Haocxy::ks Rri dge, W 08038

     " S:vstem           safety Injection                                                                                                                                                                                             Nucienr           Class I 5 ;:: Component repaired, modified or replaced _l...,4...,S..I~l.,.4L04"--'7~a-~_ve~~--------------------------
        =     Nameofmaiufacturer --~Ri~cc,,,_k!Je...,..~l~l"'--T                        .......

n~rce*TT\;:4_.,..~ti~*~craA*.....,1..___ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

        =: Identifying nos.       2-CSBE                                                       N/A                                                                NIA  ,                                                                               1978 (mfr's. serial no.)                                   (Narl.Bd.Nc.)                                     Ourisdicncr.al no.)                                              (other)                                         (year built)
Constructior Code A-SME Sec III 1 971 Ti.: nter 1971 _ _ _ _ ___._,J\.,_l.... A.....__ __

ANSI B31. 7 1969 JMiponl970 Add. (Code Case(s)) (Code Class) _ Section XI 1983 summe-- 83 WA (edition) (aodenoa) IC::ide Case(s))

     - .1cplicable edition d ASME Code Section XI under which repa~ ~edifications or replacements were made:                                                                                                            1983             S83                  ~N-/A~--

(edition) *acoe!1da) (Code Case(s))

     - .1cplicable edition d Construction Code under which repairs ncciiications, or replacements were made:                                                                                                       *1971                 W'Zl                  N/A
                                                                                                                    ~                   Sec. III                                                                   (edition)                                  (Code Case(s))

_ :iesign responsbiii-=-es - - - ' u . l . " " " ' " " ' - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

           -ests conducted: rtdrostatic O                          pneumatic                     D desr;r :ressure [ **Pressure                                                                           psi          Code Case(s)             N/A iescription of~            Repl ar.pd valve with $/N 0)-569 year Built 1986. Manufacturer Rockwell
                         .                                                                                  :.;* :f acc::onal sheet(s or sketch( es) is acceptable if properly identified)
  • Inte!Tlc3t i anal .

94

   =~      )' - z.'Y       1s 9:t.. .        Signed. _ _PSE                       __&G    __          eo_._-ru::.:  __-_ear      _ _Dept         _ _* __                                                                                        Principal               ~

(authorized representative) (title) CEmFICATE OF INSPECTION

  .. re undersigned. holding a valid commission issued by The Natera 3oard of Bo1iier and Pressure Vessel Inspectors, and certificate of competency issued by re mte or province o*               New Jersey and employee :y                                                                                    Arkwri t Mutual Insurance Co
t MA hz..e inspected the repair, modification or re:iaa:nent descrit::ed in this rep0rt on -2 , 199).., and state that to the
 * -~ :rl my knowledge and belief, this repair, modification or repla:srent has been made in accordance with Section XI of the AStJE Code and the National
   - are rules as defined in the publication NB-102, current edlion S'f signing this certificate, neither the Inspector nor his employer makes any warranty, sed or impried. concerning the repair, modification or repla:a;.ent describeC in this report. Furthermore, neither the lnspectt nor his employer shall be in any manner for any personal injury or property damage :r a :css of any kird arising from or connected with this inspection.                                                                                                                            /
               &--                                               ~                                       c- ,,,                          .                                                            .         __factocy M.ltual                     system *
am~O~*-~J~J_. 1~. SignedV ( *  ;.~ Commissions._N~~"--"J-'7_-='j=------------

(lrspeccr, (Natl.Bd.No.(induding endorsemens)s::ale or province and number) This form may be obtained from The National Board of 5oiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229.

                                                                                               *Page _L of _l_

FORM NR-1 A'rl'ACHMENT Code Job Package No.: S92-280

  • 2.

3. Work performed by: Owner: Location: Public Service Electric & Gas Co., Nuclear Dept. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 Public Service Electric & Gas Co. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 Salem Nuclear Generating Station Foot of Buttonwood Road, Hancocks Bridge, NJ 08038

4. System: Safety Injection Nuclear Class: -=1.__--,----,--__

ID of Component Replaced: -=1~4=S=J~1~4~4~--V~a=l~v~e=-_--,--_--,--_ _ _ _ _ _ _ _ _ _ _ _ __ Name of Manufacturer: Rockwell International 2-C58E N/A N/A N/A 1978 =Y~e=s~-----~--=- Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Original Const. Code: ASME Sec.III 1971 Edition W71 Addenda, Code Class .l___ Code Cases: N/A ID of Replacement: -=1~4=S~J~1~4~4-=---_-____,_V~a=l~v~e~-----,-----------,----,------,----,----,----,--_ _~ Name of Manufacturer: ~R=o=c=kw:.:.:...::e~l=l=--=I=n=t=e=r~n=a~t==i=o=n=a=l,~------,-----------~ CD-569 N/A N/A N/A 1986 =Y~e=s~---~-~--=- Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: ASME Sec.III 1971 Edition H2l_ Addenda, Code Class l_ Code Cases:N/A__

   ==============================================================================

ID of Component Replaced: ~me of Manufacturer: ~ Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Original Const. Code: Edition Addenda, Code Class Code Cases: ID of Replacement: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No~ Other Year Built ASME Code Stamp'd.? Replacement Const. Code: Edition Addenda, Code Class Code Cases:

   ==============================================================================

ID of Component Replaced: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Original Const. Code: Edition Addenda, Code Class Code Cases:

   --------------------------------------~---------------------------------------,--

ID of Replacement: Name of Manufacturer:

 *Serial No. Nat'l. Bd. Jurist No.                Other        Year Built            ASME Code stamp'd.?

Replacement Const. Code: Edition Addenda, Code Class _--,---~ 1 . , d e Cases:

   ============~=========================================~~===================

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) I TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1

  • 1. Work performed by Public Service Electric & Gas Co. - Nuclear nept.

Foot of :a.rttorrwocxi Road, Han::ocks Bri?;Je, NJ

                                                                                                                                ~)

1.icir..i 08038

2. Owner_ _....:Pub:...=:..:l:..:i:..:c:c......::Servi~~*-ce~..;:;El=ectr...::..==ic-=--and=::......:Gas=::.......:Co=..:..________________________

CJP #S92-285 (1'9PM ~*1 P.O. no. ;ao. no., .. c.1

                                                                                                                             ,....... )

Foot of Buttorrwood Road, Hancocks Bridge, NJ 08038

3. Name. address and identification of nuclear power plant Salem Nuclear Generati.JB station Unit #1 Foot of Buttorrwood Road*, Hancocks Bridge, NJ 08038
4. System Reactor Coolant Nuclear Class I
s. a: Component repaired, modified or replaCed_-'l"'"C"'"--'PRH=-==-=--=l_,_7.:o.9_.....(=SUpp:?-====rt~)-----------------------

b: Name of manufacturer PSE&G

                                       ~-~===='-----------------------------------~

c: Identifying nos. N/A N/A N/A N/A 1975 (mfT.'c MriaJ no.) (PUl'I. Bd. No.) Qurfldlclional no.) (Olhet) ~ buill) d: Construction Code PSE&G ~ S-C-1969-I:SP-6445 N/A I (__,,.,) (adcSenca) (Code C-(9))

6. Section XI 1983 SUnmer 83 N/A (edlban) (lldcMndaj (Code Cae(*ll
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 $83 N/A Plde c..\111
8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made:
  • N/A
                                                                                                  *PSE&G Spec S-C-1969-ISP-6445                                                (Codel      {edition)      (addendaJ       !Code Case(a)I
9. Design responsibilities__.PS~E&G.,.,.,=-------------------------------------
10. Tests conducted: hydrostatic a pneumatic a design pressure I] pressure N/A psi Tetp. N/A '
11. Description of work Replacement of pipe clanp for the above noted pipe sua;prt due to (u. ol ..:ldttional ll>M(a) ar IU!c:h(a) ii acceplabie I ~ ldentlfiedl cx:>rrosion discovered durirg insezyice inspection.
12. Remarks. Work Qrder #: 920501120 Defici~ Report #: SMD 92-486 O:Sign Olarge Package #: N/A Rev. N/A Rev. 2 see attached pages for I:E.scription of Replacement. N/A CERTIACATE OF COMPUANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NS-102, current edition.
-;iz~-**:~q: . ;_ 36 irnc Q> *
                                                                                                      .:::~::**-:;.J~td ***--~ ~-

('9palr or;anizatlon) (authorized ~) ) CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boller and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New J~ and employed by Arlavright Mutual Insurance Co of MA have inspected the repair, modification or replacement describe in this report on , _q. , 19!i0nd state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NS-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Date 7. . Z/ ,19f"'?-signed * ~ . Commissions df'{Jry Mutual System

                                                                                                  !Authorized lna~or)                                             (NalLBd.No.(lncludl"lil ....ion.ments)llal* or p<ovinc9 and numi..tj may be obtained from The National Board of Boiler and l'resSUre Vessel Inspectors, 1055 Qupper Avenue, Columbus, OH 43229.                                                                                           I NB-81 Rev.6

FORM'NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) I TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 1 . Work performed by Public Seivice Electric & Gas Cc. - Nuclear Dept. CJP #592-291 I- "'""""";91""""_,,,,., P 0. no. roe>* no.,llK.

  • Foot of Buttonwood Road, Hancocks Bri?Je:HJ 08038
2. Owner _ _:::..Pub=l=ic.::.._;Serv=-=~l.:::..'ce~_;El;;;;;;:::..ectr~~i:...:;c-.:...and~-G.::..:;a::.=15:;:..._Cc::....::.....:.....__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

Foot of Buttonwood Road, Hancocks Bri¢ge, NJ 08038

                                                                                                                                  ~)
3. Name. address and identification of nuclear power plant salem Nuclear Generatil"g statiai Unit #1 Foot of Buttonwood Road, Hancocks Bridge, NJ 08038
4. System Reactor coolant Nuclear Class I
5. a: Component repaired, modified or replacad_=l.PB===6_V.~al.=-'-Vi"""e'-----------------------------

b: Name of manufacturer _ _..i.>o"""6.l...---------------------~------------- c: Identifying nos. 801354Bl3M N/A N/A N/A 1966 (ml!. 's MriaJ no.J (Nml'I. Bd. No.J IJuf19dlctionaJ no.) (Gthet\ (yMI buiftJ d: Construction Code kt E-S.pec. 676258 1966 N/A N/A 1 AN.SI B31. 7 1969 ~niciJ970 Add. !addendal (CodeC-(WIJ

6. Section XJ 1983 St.mmer 83 N/A (edKlonJ (add9ndal (Code ~)
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83.. _N~V_A___

(edition) c-llMl pm c::..coi1

8. Applicable edition of Construction Code under which repairs, modifications. or replacements were made:
  • W E~. 676258 _N~V~A ___
                                                                                      *1966/ANSI 831. 7 1969 Fd. 1970 ld:l. !Code! (edition!                                                                          ~                    ICode e&.(sll
9. Design responsibilities_.PSE&G...u......,....__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

10.. Tests conducted: hydrostatic a pneumatic a design pressure D pressure NOP psi Temp. N/A **Other

11. Description of work Repla<W yalve stem asffilrhly an:I bolting.
                                                                            !we "' ..iclllional .,_,,, .... ~,.., *                           ~            ' ptopelty idenllied)
-~~~~~~~~~~

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair,.modification or replacement of the items described above conforms to Section XJ of the ASME Code and the National Board rules as defined in the publication NB-102, current edition.

°';;'5'Aulho**..:.~~ ..~...36 w Q>,~;:*=**'"aT!!okl*-*-~>e1 "'¥*

(_.ir cx;anlalianl (aulhor1ad ~) ) CERTIACATE OF INSPECT10N I, the undersigned, holding a valid commission issued by The National Board of Boller and Pressure,Vessel lns~ectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwright !ol.itual Insurance Cc of MA have inspected the repair, modificatiqn or replacement describe in this report on F. .z; , 19~d state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection. Dale f:(, ,19<fh,good ~ (. ~ Comm1..1ons d/1f-Jldone,_)_* M.It:ual. Syst.eJn iAu1horized ln1peclor) (Nall.Bd.No.(lncludi"ll ., or p<ovfnce and numbel) may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. / NB-al Rev.II

FORM NR-1 REPORT OF REPAIR (J MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 c;>f 1

     ,     Work performed by Public sezvice Electric &                                           Gas Co. - Nuclear                       tept.              C1P #S92-296 (nameI                                                   (19peir organiZation'* P.O. no. job. no.,lllc.1
.         ~~Foot~~o~f;;.._:suttonwood~~~~~Road~__._,_Hancocks~~~~Br~id;e-"'_,_,_NJ~~oa-oJ_s~---~~~~~~~~~--~-

1add*aa1

2. Owner _ _ _Pub __l_i_c_Serl __ i_oe_El_ectr _ _i_c_arrl __ _ _Co_._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

Gas (nameI Foot of BUttonwood Road, Hancocks Bridge, NJ 08038 (add real

3. Name, address and identification of nuclear power plant Salem Nuclear Generat.in; Statia'l Unit #1 Foot of BUttonwood Road, Hancocks Bridge, NJ 08038
4. System Olemical Volume c6ntrol Nuclear Class I
s. a: Component repaired, modified or replaced_-'C'"'"-CV-:...:...CS=---=58~7--=Harg=~er=-------------------------

b: Name of manufacturer ___P$E&G_=~------------------------------------ c: Identifying nos. WA N/A N/A N/A 1975 (ml! ."s M!ia1 no.) (Nal'I. Bd Na.) Quri9diclional no.I (oltle!) (year bui~) d: Construction Code PS Hanger S.pec. S-C-1969-I:SP-644::.5_ _ _ _ _ _ _..;:.N::.c.../.=.cA=-- 1 ANSI i-Baa.. 7 1969 Ed. l~. !CodeCase!*ll

6. Section XJ 1983 Summer 83 N/A (edition) (addenda) (Cod9 CU.(1)1
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 _N_,_V_A___

(edllon) (adderlcMj

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: -*--
                                                                               *PS Han:Jer Spec. S-C-1969-I:SP-6~ (edllionl                                                   !add9"daJ
9. Design responsibilities PSE&G ANSI B31. 7 1969 Ed. 1970 Add.
10. Tests conducted: hydrostatic a pneumatic a design pressure a pressure N/A psi Terp. N/A *
11. Description of work pertonrea weld repair on haooer that was renoved to (UM d olddttional .,_(I) or IUlcll(nl II A"9Plable N ptopelty identified)
 ~1--~f~a~c~ili......i~ta~te"'50..~ma  ......j~n~t.enance"""'"...._""""'~*'----------------------------------
12. Remancs. _ __._,Wo~r....

k_Ord""*"=er.,..___.#._.:.__..9..,,2=0~42=9=-0=-7'"""'9"--------------------------- Deficiercy Report #: N/A

                            *No Presavice Test Required CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or repiacement of the items described above conforms to Section XJ of the ASME Code and the National Board rules as defined in the publication NB-102, current edition.
  • Certificate of Authorization no. to use the "NA" stamp expires Oct , , 19--94-.

36 3 Date ft:>/ q 19,9_Z. $gned "R;E&C CG, -Nuclear eept. (reo.it orpnizallonl Q \/ h'o ~ (authonled ~l Prircipal Ergr p111e1 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure yessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwr1 t Mutual Insurance Co of ~ have inspected the repair, modificati_on or replacement describe in this report on , 19~and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury o roperty damage or a loss of any kind arising from or connected with this inspection. Factory Mutual System

      *Date                        , 1eE Signed                                                                               Commissions    ,otn~ IJ v /t?~g NB-81 Rev.6
                                                                                                                             ~
                                                                                                                 '~.

FORM NA-1 REPORT OF REPAJR 0 MODIFICATION 0 OR INSTAL.1..ATION OF REPLACEMENT(S)~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 1 Work performed by PUblic Service Electric & ~~* - Nu::lear Dept.. CJP #S92-29i (l'ap&r' 0f9&"'2*hon'1 P 0 no fQtl no .... c:.. Foot of arttarrwoc:xJ Road, Hanax:ks Bri¥, NJ 08038 2.0wner _ _~Pub'--~l_1~*c_.Se.rv____;_i_ce El_ectr_o._;:1~*c_and~-G~:>a~LS"--Co.:_::__* ________________________ 1name. Foot of El.Ittorrwood Road, Hanax:ks BriO;;Je, NJ 08038

3. Name. address and identification of nuclear power plant Salem Nuclear Generat.i.rg station Unit #1 Foot Of azttorrwood Road, Hanax:ks Bridge, NJ 08038
4. System Olemical Volume Control Nuclear Class I 5 a* Component repaired. modified or replaceo_-=1~~~5~'V<'""al=ve-'-=_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

b: Name of manufacturer Cl:!:e-Vulcan c: Identifying nos. N/A N/A N/A N/A 1968 (mf!.'s ~ no.) {Nm'i. Be:. No.J Oun.diclional no.) (olhef) ty..., buiH) d: Construction Code West~ E-Sp:!c. 676270 1966 -------~N_/~A~- _ _ ____,1=------ ANSI Ba~ 7 1969 Ed. 19'~. !Cod<' euei-11 5 Section XJ 1983 SUmmer 83 N/A (IOdHion) (llddenda) {Cod9 C..(1)) 7 Applicable edition of ASME Code Section XI under which repairs, modifications. or replacements were made: 1983 $83 ..N~/"""A~-- (IOdHion) !addenda)

8. Applicable edition of Construction Code under which repairs. modifications, or replacements were made: -*--
                                                                     *West~                            E-Spec. 676270 l966;'*J                        (IOdHiOn)         (ldd*nda) 9 Design responsibilities PSE&G                                       ANSI B31. 7 1969 Fd. 1970 Add.
10. Tests conducted: hydrostatic D pneumatic a design pressure D pressure NOP psi Tenp. N/A *
11. Description of work Re,plag:rl plug ard stem aS5ffl!Ply.

camACATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items describe.d above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition.

~;;t . ., . ;;;;, $~, . . 36 ' Qo * . : : : * : :

(repair o<ganizalion)

                                                                                                              "Q'.;rn ~=zr;~if,U ~-

{author.zed ~) (I ) CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commiSsion issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwri t Mutual In<;urance Co of MA have inspected the repair, modifica~n or replacemanl describe in this report on ,1 and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XJ of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any perso Injury or propef1Y damage or a loss of any kind arising from or connected with this inspection. Date f:. / t- ,1f! ~Signed (," Commissions ~fj°cy Mutual System (Autllo<ized lnspec!OI) (Nall.Bd.No.pncJuding endonlements)S1ale or provinu and numberJ may be obtained from The National Board of Boiler and PresSure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB-81 Rev.6

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) fil TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of 1 1 work pertormed by Public Service Electric & Gas Co. - Nuclear Cept. CJP #892-300 ('l&me) Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 (address) 2.0wner _ _ _Pub __ l_ic_Serv___i_ce __ E_l_ectr __i_c_an::J __Gas __ Co_._______________________~ (name) Foot of  :&Jttonwood Road, Hancocks Bridge, NJ 08038

                                                                                                      'addrna)
3. Name address and identification of nuclear power plant Salem Nuclear Generating station Unit #1 Foot of .Buttonwocd Road, Hancocks Bridge, NJ 08038 4 System _ _~R=ea~cto~=r_C_:cx:>_l_an_t_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _--'-Nu'-=-'cC-'l'-'e'--'a-"rO---C'""l~a~s:o..:;s_I"----

s a* Componentrep~red,modffiedorrep:a~d-~R~ea=~=~~~=c=k=e=t~f=o=r~=~~~~=*c~~=~~=S=n=~~~~l=C~-=~~~-~0~0~7~-------

b. Name of manufacturer _ _---=Pa-=c=i=*=f-=i,_,c=--=Sc===i=en=-=-=t,,_,i~f,,_,1=*C = - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

c: Identifying nos. _ _,1~7~6~7~6~-----~N~/A~--------~N~/=A~_ _ _ _ _ __,N,.../.__,A=-_ _ _ __,1=9'-'7'-'6~--- {mf!.'s seriai no.} (Na!'I Sd. No.) Ourisdk:t.ana! no. J (othe'1 (yee* buitt* d Construction Code PS Snub~ 73-6402 1976 NIA 1 ANSI B31. 7 1969 Eih'°"l970 Add. (addenda) (Code Case1s)) 6 Section XI 1983 summer 83 N/A (9d~oo1 (addenda) (Code Case(s)) 7 Applicable ed;tion of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 N/A (odttion) (addenda) 8 Applicabie edition of Construction Code under which repairs. modifications, or replacements were made: _*__ 1980 W/82 N-71

                                                             *ASME        Sec.           III/PS Snubber                     Spec.         73-6402Jcoo.~                CodttionJ     (addenda:
9. Design responsibilities PSE&G ANSI B31. 7 1969 F.d. 1970 Add.
10. Tests condue1ed. hydrostatic D pneumatic O design pressure D pressure N/A psi Teirp. N/A **Other 11 Description of work Rgplaced rear bracket by 'Weldina.

__ ,_ _ _ _ _ _ _ _ __ {uoe ol addrt~a' *he*11s: o* <<eleh(H) i* a~pU*bl9 ~ p<opery iOan!ifoed)

12.  !:lemarks. -~w~*o~r=k~Ord~~e~r~#~:~9~2~0~5~0~4~1=2~5_ _ _ _ _ _ _ _ _ _ I:e~f~i~c~i~encv~"----'R~e....po~rt~~#~:~SMD~-=9'""'2_--=-5-=-0-"-3_ _ __

Design Ola.'1Qe Package #: N/A Rev. N/A See attached pctges for Le5cription of Replacement. N/A

                              **VT-3 Pre.service Examination CERTIFICATE OF COMPLIANCE We ~rtity tr.a: the statemem" made in this repor. are correC'. a.no the repair. modif1cat1on o; rep:acemen1 oi tr1e items described above contorms to Section Xi of the ASME Code and the Nat.or.al Board rules as defined in the publication NB-102, curren1 edition.

Certificate of Authorization no. to use the 'NR" stamp expires ~'/?~ , 19-*. Date .7/i 19.~ Signed~.NIJGlear (r&pair o<ganLZa!oon) Dept. Q *J. _,ki~ J-(author'.zed re.,,_nta!hl9) Principal En)r (1~1*) CERTIACATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure yessel Inspectors, and certificate of compelency issued by the state or province of New Jersey and employed by Arkwrl t Mutual Insurance Co of MA have inspected the repair, modification or replacement describe in this report on , 19 2--arid state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection .

                   ...,    *                                ~                     I""'"" /                                                               , _.factory Mutual system Date         1--f            ,19J.l-Signed                 rl;/            z. .. l-~                                Commissions __N_J_J~           17--..5__________

(Authorized lnspectOlj (Natl.Bd.No.~ncluding endorsemenls)slate 01 province and  !'lumbe~ rm may be obtained from The National Board of Boiler and Presiure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB-81 Rev.6

FORM NR-1 REPORT OF REPAIR Ii MODIFICATION 0 OR INSTALLATION OF REP....&CEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 2 rk perf-..r-lBd by Public Service Electric & Gas Co. - Nuclear Dept. CJP :fS32-301 (nan-. - ~nizmion*s P. 0 . ...._ cc '\O.,etc.1 Foot :=Ji Buttonwood Road, Hancoc::ks Bridge, NJ 08038 (addressj

  ~:>wner~~-~~_l_i_c~Serv~~i_ce~_El~ectr~~i_c_ard~~Gas~~CO~*~~~~~~~~~~~~~~~~~~~~~~~

(namej Foot of Buttonwood Road, Hancoc::ks Bridge, NJ 08038 (addreaj _ Name, adtt"5!i and identification of nuclear power plant Salem Nuclear Generati.rn statim Cbit #1 Foot of Buttonwood Road, HancccKs Bridge, NJ 08038

  ""* System               .steam Generator Boiler Feedr.ater                                                                                                                 ~ear                 Class II

_ a: Compone:-:: ""!l!Daired, modified or r e p l a c e d _ - = l . , , , 1 B F 2 2 = - = ' - - - - - - - - - - - - , - - - - - - - - - - - - - - - - - - - - - b: Name ct. -amufacturer Rockwell Inten1ational c: ldentifyin; "=* ESJC-45 N/A N/A N/A N/A (mlr.'s serial no.) (Nal'I. Bet. No.I (jurisdiclional no.) (olhe<) tyN!" :>all d: Constructar ::Ode ASME Draft Code for Bmp & Valves 1968 Fd. 1970 ldi. N/A 2 AN.S: 331. 7 1969 i'dQnJ1970 Add. IBddenda) fCode C!lse(s)J

  -      Section Xl                                1983 (edhlon)

SUniner (adderldal 83 Nt'.A C::.- ::-11))

  -      Applicable !C::i:m of ASME Cade Section XI under whict" ~eoairs, modifications. or replacements were made:                                                1983             583                      NIA c..... C!mlsll
  ~      Applicable !!C=n of Construction Cade under which repa.irs. modifications. or replacements were made:
  • N/A
                                                                      *ASME Draft Ccxie for Pl.mps & Valve/ fCode1 ..cum Design res:cr.5ibilities PSE&G                                 ANSI 531. 7 1969 F.d. 1970 1\dd.
 *c.      Tests cono..c:e::: hydrostatic         a      pneumatic  a desig* pr:issure a pressure NOP psi Telrp. N/A
  • Perfooned weld rep3 i r on valve seat arrl bcQy am replace: boltioo.

(use of addrtiona ""-II*) or sk11lch(es) ;s ~e tt properly identified) Remancs:~__.Wo-==r=k.........,,,Ord===er=-#~:.__,9~2=0~4=1=8=0=5=0~~~~~~~~~~~~~~~~~~~~~~~~~~- Deficiency Report #: SMD 92-519

                              *System           Insavice           Test Perfonned                     at      NOP /N o-r CCRTIFICATE OF COMPLIANCE We certify th.a:~ statements made in this report are co~ and the repair, modification or replacement of the items de!c'1bed above coni:mls to Section XI ct. re 4SME Cade and the National Board rules as ::lefined in the publication NS- 102, current edition.
ertificate o! "-ttnorization no.
  • c use the 'NA° stamp expires Oc:t. . , 19---9t-36 31 19,'l..L_ Signed ffiE&G Co, ~iJuolear ()apt. _, ~.L-..:4. '
                                                                                   ,_.. organizelionJ                                    (aulhorlzed  ~

CERTIFICATE OF INSPECTION

, the unde~. holding a valid commission issued by 7he National Board of Boiler and Pressure Vessel Inspectors. arc :mrtificate of con::ietency issued by tM ~te or province of New Jersev and employed by Arkwri t :osurance Co of MA T!ave inspected the repair, modification O' '"9P*acement describe in this report on - - - H - - - - " ' - - L - -
iest of my krooRedge and belief, this repair, modification o- .~:acement has been made in accordance with 'on Xl *o! tte .S.SME Code and re National Board rules m :::efined in the publication NB-102, current ecioon. By signing this certificate, neither the Inspector nor tlis -.c11oyer makes tr:'f warranty, expressed or roiled, concerning the repair, modification :r re;::>lacement described in this report. Furthermore, neither tte .r.spector l'lOI' his employer shall be liabl~ r :any manner for any pers injury or prccer=y damage or a loss of any kind arising from or connec:19C ¥rtr. this inspectior.
                  ,; ,,-_,r                                                             -                                                              -~~System
>ate ~ ~, ,19qi Signed c; Commissions_..~'-=-;;;.....,,,c-'...._..___ _ _ _ _ _ _ _ _ _ __

(Nat1.Bd.No.[rocluding ., *d:n""""' 11ai1stale "' pn:Mnce 1111:! riumber)

   "This form may be obtained from The National Board of Baier and Pressure Vessel Inspectors, 1055 Crupper Avenue, Cohint:ws, OH 43229..                                                                            NB-81 Rev.6

Page _L of _L_ ' FORM NR-1 ATTACHMENT Code Job Package No.: S92-30:

  *2.

3. Work perf onned by: Owner: Location: Public Service Electric & Gas co., Nuclear Dept. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 Public Service Electric & Gas Co. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 Salem Nuclear Generating Station Foot of Buttonwood Road, Hancocks Bridge, NJ 08038

4. System: Steam Generator Boiler Feedwater Nuclear Class: 2
   ---------=======-----

ID of Component Replaced: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Original Const. Code: - Edition Addenda, Code Class

                             ~~-------

Code Cases: - - - ID of Replacement: --==-S~t=u=d=s...__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _~ Name of Manufacturer: __;.:.A=l~l~i=e=d=--=N~u~t=-=&-=B=o~l~t=--=C=o~*:..__-,-------------~ N/A N/A N/A =N-/=A'--- N/A =N~o_ _ _ _ _ _ _ _ __ Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: ASME Sec.III 1977 Edition~ Addenda, Code Class:_ Code Cases:~N-/A""'-- _ __ of Component Replaced: e of Manufacturer:

                             ~--------------------------~

Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code stamp'd.? Original Const. Code: Edition Addenda, Code Class Code Cases: ID of Repl~cement: ~N=u~t=s...__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _~ Name of Manufacturer: Allied Nut & Bolt Co.

                                ===='-="""-""'-=-=-=-===-------=-~--------------~

N/A N/A =N_/=A..,.___ N/A N/A _N~o_ _ _ _ _ _ _ _ __ Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.: Replacement Const. Code: ~A=S=M=E---=S~e~c~.'----'I=I=I=-=1~9~7~7Edition ~ Addenda, Code Class .:..__ Code Cases:~N_/=A__ ID of Component Replaced: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Original Const. Code: Edition Addenda, Code Class Code Cases:

   ----------------------------------------------------------------------------~

ID of Replacement: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? lacement Const. Code: Edition Addenda, Code Class e Cases:

FOR1V NR-1 REPORT OF REPAIR ijJ MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) : TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS .ork per.--~ by Public Sel:Vice Electric & ~~* - Nuclear .Dept. CJP #892-302 (repair organizauc:..,*, P C. n:: :m. 1C. . .-=... Fm: cf Buttonwood Road, Hancocks Bridge, lU 08038 iaddreSll Fd:llic service Electric am Gas Co. (name I FocX. cf Buttonwood Road, Hanccx::ks Bridge, lU 08038 1-1

3. Name, adc:r.!!SS 11.nd identification of nuclearpower plant Salem Nlx:lear Generati.rn station unit #1 Foo:. of~ Road, Hancocks Bridge, lU 08038
4. System S-...eam Generator Boiler Feedwater Nuclear Clcss ::r_
5. a: Compc:>OEn ~red, modified or replaced_*-=12=BF2=-==-=2.__V,,_,al=-v.:...e=---------------------------

b: Name rf. ;.ariwfacturer_ _~Rockw...,..=..,_,,e,..l,,..l~--------------------------------- c: ldentifytn; "1C!i. PSJC-20 N/A N/A N/A NIA (mfr.'s sefial no.) (Nal'I. Bd. No.) ~no.) (olhef) ~,,. d: Cons:ruc:icr. -~e ASME Draft Cocie..__.f...,o..,rL............,""" Pung; __ & .=..Valves

                                                                                                                  ...         1268 Eki. 1270 Add.                                 N/A                  2
            ~         B:!:...7 1969                    ~970             Add.                (addenda)                                                  fCode C&oe(s))_                              IC.-Clml
6. Sectior. X: 1983 S\l'TT'l'Pr BJ N/A

(-.) _ (adderGJ (Code C:U.(s))

7. Applicable !Citior of ASME Code Section XI under which repairs, modificatiO'lS. or replacements were made: 1983 S83 J/A (edition) (llddendml -~  ::...o.i1
8. Applicao6e !diner of Construction Code under which repairs, modifications. et replacements were made: * ..J.2.6a 1970 J/A.
                                                                      *A5ME Draft Code for PlIIrq:S & Valves/ ~el (edition)
9. Design res:crsbilities PSE&G ANSI B31.7 1269 Eel. 1970 Add,.
10. Tests cono..c:ec: hydrostatic a pneumatic a design pressure a pressure NOP psi TeIIp. N/A **Other ot work Perfooned weld repair on valve tniy and seat and replaced boltirg.

(use ol additional sheet(*) or sketch (a) is oc::ecr;able K property idenliied)

12. Remancs.: _ ___,-WO"'"""":r ___..#_.:_2...2""0__.4_l"""8_l_l2-----------------------~-----
                                ...k...__,,Ord,,,_,,,..,er
leficiency Report #: SMO 92-536
                           **System In.service Test Perfonned                                                 @ N'.>P CERTIFICATE OF COMPUANCE We certify trm ~ statements made in this report are correct and the repair, l'lOdification or replacement of the items described above                                                                 con~a      t::

Section .X: <T.1'.e ~ME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate er. ~rization no.

  • to use the "NR" stamp expires Ck:t. , 19---94-.

36 31 Oat~ T --:; ,;; 19,U Signed :ffiE&C ee. Nuclear Qept. (repair organizalionl 7

                                                                                                                               .L...L/.. L                * ,.. ,

(lli.Jlhorlzed repnisenlallve) F'?jr. CERTIFICATE Of HSPECTION I, the unOersgnec. holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of COTTCetHl'JCY issued by thf mHt!! or province of New Jersey and employed by Arkwright ~JEil ~ C: of MA -:cave inspected the repair, modification or replacement descr:be in this report on f~ , 1~ trat :c t"le best of rr.-11n:w1e::1ge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code anc ne '>a:>c<ial Board ruties as :eimed in the publication NB-102, current edition. By signing :his certificate, neither the Inspector nor his employer maJc:es BTV NaLamy, expressed o' *mc:lited, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor hir ~01~ shall be ::atie :r i!TlY manner for any perso injury or property damage or a loss of any kind arising from or connected with this inspectior.

             '3" -: f               ,1lf VSigned                                        £                                       Commissions              N:!'Jrfry                   Mutual Sys:Em.

(Nall.Bd.No.finc:tudlng endorsements)-* 0t Pf'O'l"1CIP n: ~ This form mar be Dbtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH "3229.

FORM NR-1 REPORT OF REPAJR VJ MODIACATION 0 OR INSTALLATION~ REPLACEMEHT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWEF. ?l.ANTS Page 1 of 1

 ~                 per.X"'.'""tfld by      Public Service Electric & Gas Co. - Nuclear 0ept.                                                                                          CJP #S92-303
,.,                                                                                                                      !name)                                                            ffepalr organa..z-- * "' 0. no. job. no.,e!c.J Foot of Buttonwood Road, Han:xx::ks                                                        Bz:"i¥,           NJ         08038 (name)

Foot of Buttonwood Road, Han:xx::ks Br'ia:Je, NJ 08038

                                                                                                                     -)
3. Nar."le. address and identification of nucleaqxiwer plant Sal.em Nuclear Gene.rat@ ~-i.m Unit #1 Foot of B.lttonwocx:i Road. Hancocks BriOOe, NJ 08038
4. S,.s:en steam Generator Boiler Feedwater Nuclear Class II
s. a ::.:.c--iponent raoaired, modified or replaced __l3~-BF2~~2~V,~al_v~e~---------------------------

b ~e of mai-iufacturer___Rockwe...,.."""'....,""J""'J..________________________'_*- - - - - - - - - - - c oentitying nos. _ _._PS]..,,,._C"""-_,5...,9..___._ _~t\..,,,._,/A....___________acl'{¥-/....,A.___ _ _ ___,J&IA=-"=-------'N...,,/,_,A=---- lmtr .'s serial no.) (N". 8c. No.) ijurildictional no.) - (year buiH) d Constructior. .:Ode ASME Draft QrlA for Pimp=; & Valves 1968 Ed. 1970 .Mi. N~/=A,___ __,,2,,___ _ __ ANSI B31. 7 1969 Fiiliik><il.970 ld:i. ,_ !CodeCaesil Code Class)

s. Section Xl 1983 SUmmer 83 __.N...,./!-=------------

(Ddttion) (llddende) jCode C-(s))

7. A:oiicable edition of ASME Code Section Xl irder which repairs. mo::1ifications, or replacements were made 1983 S83 N/A
                                                                                                                                                                                  ..:lttion)         (addenam              pm     c:-(sl) 8      A..""'Clicable edition of Construction Code under .nic:t1 repairs, modifications, or replacements were made:                                                       -*--         ...19..68_      ~                 N/A
9. Cesign responsibilities PSE&G *~ ~~ ~ m: ~JiAa:7alves/ tc=m iedttionJ (_...,..

(Code Case(s))

10.  :~ conducted: hydrostatic 0 ~~ design pre~e [! preSlU!_e~!i NOP TE!l!tJ N;~ **Other

~1ption at work Perfo d repair Valve r:xxlY arD seat. - (um :I ICdilional ahea(s) a -.::ti(n) is acuplabl* tt properly Identified) Work O:rder #: 92041S113 1~ Ferarks: _ _""""""f'r-,....h' De ic1ency ........,.......,...--i:~ Reper .........~t---.*~~llf'l--&t=l~>t-----------------------------

                                                                                      +. 5'MD 92-534
                                 **System Inse:rvia:? Test Perfurnal @ NOP CERI HCA.TE OF COMPLIANCE We ~ify that ~ statements made in this re~ are correct and the -epair, modification or replacement of tra *t"erls described                                                                          aoo.-e    conforms to Sec:io" Xl of the ~SME Code and the National Eoard rules as defined 1n the publication NB-102, current editior.

CerT.icate of Authorization no. ' 36 to use tt.ie "NR" stamp expires Oct. 3, r9___..2i_. 19,J_<_ Signed PSE&G Co.-Nuclear Dept. ,,f4L. i.4 Principll Engr. (r.pair orgena:;moon)  ;> (authorlied ~ CEA IHCA.TE OF INSPECTION I, h :A""ldersignee, holding a valid commi~yiie Nationat Board of Boiler and ~i'.~ I~ a~f mipetency i~ the state or province of . and employed by----------,,.........,=-=-~--..,,-=-------- ol  :-iave inspected the repair, modtication or replacemern describe in this report on g:;'( , 19iJ:2:and state that to the bes at :ny knowle!!dge and belief, this repair, modfication or replacement has been made in accordance with Secicr. Xl of the ASME Code and the National Boctc .-.Jles as c:efined in the publication NB-102. or.ent edition. By signing this certificate, neither the lnspecc- .-or his employer l'T'..akes any warranty, exi;ressed or impiied, concerning the repair, mo:ification or replacerrent described in this report. Furthermore ~eiittler the Inspector nor his employer sha1 :::e liable ir. any manner for any personal irtury or property damage or a loss of any kind arising from o~ ~

                    £, "LJ                                               (),rn!t,;J (" ~                                                                                AJX~,.__;_/"""r_J'-----------

Dale ,19'fl..-signed T (Authorized ln5<:ector) Commissions__ (Natl.Bd.No.(incuain; endorsements)- a ;J'OYince and number) farm may be obtained from The National Baird of Botler and Pressure Vessel Inspectors, 1055 Crupper IWerue. Columbus, OH "3229. NB-81 Rev.6

FORM NR-1 REPORT OF REPAIR I;! MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1

1. Work performed by Public Service Electric & Gas Co. - Nuclear Dept. CJP #S92-304 (name) (repair organlntlon'1 P. 0. no. jab. no.,.CC.J Foot of aittonwood Road, Hancocks Bridge, NJ 08038 (lldd'"8)
2. Owner_ _ _ Pllb

__l_i_c_Serv _ _i_*ce __El_ectr _ _i_c_am __ Gas __ eo (name) Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 (!lddl89)

3. Name, address and identification of nuclear power plant salem Nuclear Generatin;J station Unit #1 Foot of Buttonwood Road, Hancocks Bridge, NJ 08038
4. System steam Generator Boiler Feedwater Nuclear Class II
5. a: Component repaired, modified or replaced_~1=4=BF2==-=2-------------------------------

b: Name of manufacturer _ __.Rockwe====l=l,____________________________________ c: Identifying nos. PSJ0-70 N/A N/A N/A N/A (mlr.'a MriaJ no.) (Nal'I. Bd. No.) Qurltdlc:lional no.) (other) (year buill) d: Construction Code ASME Draft O"rle for Pumps & Valve 1968 F.d. 1970 Add. N/A=------=2:......._ _ __ ANSI B31. 7 1969 F.cik~970 Add. (Dddt!nda) (Code ease1sll (Code Class)

6. Section XI 1983 SUrrmer 83 ~N"'"/~A~----,---------

(edttlon) ~ (Cod* C-(*))

7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 N/A (edition) (llddenda) (Cade c:..{lj)
8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: -*-- 1968 1970 N/A
                                                                         *ASME Draft Code for Pumps & Valves/ (Cod*J (edttion)                                                           (Mld*nda)          (Code C-(1))
9. Design responsibilities PSE&G ANSI B31.7 1969 Ed,. 1970 Add*.
10. Tests conducted: hydrostatic a pneumatic a design pressure a pressure OOP psi Tenp. N/A **Other
11. Description of work Pe.rfonre::i weld repa j r on valve body am seat and re,placed bolti.rn.

(UM cl addHloneJ llhHI(*) or -ch(..) ia accepl&ble II properly Identified)

12. ..........Qrrl......,..~e-r~f~:..__.9~2~04~1~8~1~1~4.....__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

Remarks:_--iiWo1w...r~k Defjcjency Repart #: SMD 92-535

                         **System Trn;eryjce Test Perfonned at NOP CERTIFICATE OF COMPLIANCE .

We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. to use the "NA" stamp expires Oct. , , 19-94-. 36 3 Date r- ff 19,'72....Signed R;E&C Co. Nuclear D:lpta (repair otganizalion) 7.Lu.&.*L* (authorized ~) Prine~ Eng;r. CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwri~ Mutual In.suranoe Co of MA have inspected the repair, modification or replacement describe in this report on~ J , 191l...£and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with SeCtion XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Date Cf-f ,1o'f.l-s>.ood 0--./~ ~ Comm""°"' AlfffJ.ary IM:ual System (Authorized JnapedOI) (Nall.Bd.No.Qnc:ludlng o~)-* OI Pf<Ninc:e and numbel) ia form may be obtained from The National Board of Boiler and Pressure Vessel mipectors, 1055 Qupper Avenue, Columbus, OH 43229. NB-al Rcw.6

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT($)~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 Work oerformed by Public Service Electric & Gas Co. - Nuclear Dept. CJP #S92-309 . Foot of :auttonwocd Road, Hancocks Bridge, NJ 08038 (adar._,

2. Owne, _ _. ..::.Pub~..::::l-=i.c...c_Se.rv=----1_*ce

__El--=-ectr--=-.. . ::.. :1:::..c_anj==-=Ga-=lS=---=-Co-=--. fname! Foot of :auttonwocd Road, Hancxlcks Bridge, NJ 08038 (llddrnaJ 3 Name. address and identification of nuclear power plant Salem Nuclear Generatin;J station Unit #1 Foot of :auttonwocd Road, Hancocks Bridge, NJ 08038

"'   System          Olemical Volume Control                                                                                                                                              Nuclear Class II 5 a.~mponemrep~r~.modffi~mrep~cec~~l~~~~~~~~v~e~---~------------------------

b: Name of manufacturer CQpes VUlcan c:ldentitying nos. 691Q-95001-156-15 N/A N/A N/A N/A (mtr .'* - no.J (Nari. Bd. No.J ijurildic:>Onal no.) (otherj t>-' buihJ d: ~nstruction ~e W E-s.pec 676270 _ __,N,.../,_,A,_.___ _ __ N/A II ANSI B31. 7 1e69i Ed. 1970 Addoaddendal (Code Cue(1)l

6. Section X! 1983 SUmmer 83 N/A (9dHion) (addenda) (Cod9 C-(1))
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 *. S83
                                                                                                                                                                                             -"'-~--

N/A (edlllon) (add....s.J jCodo ~I 8 Applicable edition of ~nstruction ~de under which repairs, modifications, or replacements were made: -*-- 1969 1970 N/A

                                                                                                              *!i E-Spec. 676270/                                     (Cod*l      f..i111on1     (addenda;        .. (Cod9 Case(1)J
9. Design responsibilities PSE&G ANSI B31. 7 1969 Ed. 1970 hi:i.
10. Tests conducted. hydrostatic 0 pneumatic a design pressure D pressure NOP psi Temp. N/A *Other
11. Description of work Replaced pl~ arrl stern assembly.

CERTIFICATE OF COM?UANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items descri~ above conforms to Section XI of the ASME ~e and the National Board rules as defined in the_ publication NS.102, current edition. Certificate of Authorization no. to use the "NR" stamp expires eet ~ . 19-94-. 36 Date; P/1 1~. Signed-FSE&C Q).-Nucloar Dept. (repair orsianiZalion) a *Mlrld (IW!h0<1zl0d re~) Prirc~ En:Jr ) CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure ,Vessel Inspectors, and certificate of competency issu~ by the state or province of New Jersey and employed by Arkwr1 t Mutual Co of MA have inspected the repair, modification or replacement describe in this report on -z , 19_ _and S1ate that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NS.102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any pe I injury or property d age or a loss of any kind arising from or connected with this inspection. Date fJ?/J.-. ,199ksigne ~

  • Commissions µJjjJ'Y Mutual system (Nall.Bd.No.Qncludlng ondorsemenl1)stale or province and numb9<)

rm may be obtained from The National Board of Boiler and Pressure Vessel m;pectors, 1055 Crupper Avenue, Columbus, OH 43229. NB-81 Rev.6

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) ~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1

1. Work performed by Public Service Electric & Gas Co. - Nuclear Dept. CJP #S92-312 (name) (rwpair cxgmrnzmlon'* P. o. no. job. no..-:.)
  • Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 (addrea) 2.0wner_ _ _ __l_i_c_servi.

Pllb _ _* ce __El~ectr ____i_c_arxi___;;,~Ga..;;..;lS=_Co..;;_,;;__*- - - - - - - - - - - - - - - - - - - - - - - (name) Foot of Buttonwood Road, Hancocks Bri?Je, NJ 08038 ("ddtno)

3. Name, address and identification of nuclear power plant Salem Nuclear Genera.tin;;J station Unit #1 Foot of Buttonwo::xi Road, Hancocks Bridge, NJ 08038
4. System safety Injection 0 Nuclear Class II
s. a: Component repaired, modified or replaced _ _,l..,S.,,JE3"-""'><---""sa=D..,,e,,,,,ty~_,In.,,,...JJ..ect==i.,,,on::.o...-=Pl:...:==mp=-------------------

b: Name of manufacturer_ __,Pa.__c_i_f_i~c~Punps~-~------------------------------- c: Identifying nos. _ _4~54"'""""9.._;6.....__ _._ _ _...,,t{,._/.... A.____ _ _ _ _ _ _t{...,._./A...._______--"'N,,._/.....,A._______-'1=9=<--7~0:.....-_ __ (mfr.'s Mfial no.) (Nal'I. Bd. No.) Qun.ctlctlonal no.) (cilher) ()'9111 built) d: Construction Code j E Spec 676428 WA N/A 2 ASME Draft Code fOl.ft~ & Valves<~ F.d. 1970 kli./ANSicc:Ba~n 1969 F.d. 19~~.

6. Section XJ 1983 SUniner 83 __...N;,,._/....,A.____ _ _ _ _ _ _ _ _ __

(edHlon) ~aj (Code C-(a))

7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 -'S=8=3_ _ N/A (edition) (addenda)
8. Applicable edition of Construction Code under which repairs, modifications., or replacements were made:
  • W E~ 676428 - - - - -
9. Desi:~o!:1~s ~or Pumps & v~I5~1~ ~G91I!~ ~clh:ki. (Code) (edn1oni (addenda!
10. Tests conducted: hydrostatic a pneumatic a design pressure a pressure NOP psi Tenp. N/A **Other
11. Description of work Repl aQ?rl mec'hanj ca 1 seal *

(uH ol llddHlonal ohMI(*) or lkelch(n) i* acceptable if pRlpMly identified) CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no., to use the "NA" stamp expires Oct. , 19---94-. 36 31 Date 'f-,, / 0 19,~Signed PSE&G ee. Nuolear ~* .. Ld&..u(;.;,,4,, (rapalr orgcnizmlon) (autholtzed ~) Pri.nc1::1 ~. CERTlFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the_.,~te or province of New Jersey and employed by Arkwri t Mutual Insurance Co of ~ "* have inspected the repair, modification or replacement describe in this report on , 19 and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XJ of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection. Date tfr;j ,199Z--Sig~ed ~£ ~ Commissions ~9f'j-Y Mutual System (Authorized ln*pec:tOI) (Nall.Bd.No.(lnduding endOIMment*)-* or province and numbel) is form may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. N~1 R.v.8

FORM NR-1 REPORT OF REPAIR ~ MODIFICATION 0 OR INSTALLATION OF REPLACEMENT($)~ TO NUCLEAR COMPONENTS ANO SYSTEMS IN NUCLEAR POWER PLANTSPage l of 2

1. Wo..X performed by pnhl jc *Sen1ire Electric & <"--as o:i, - Nuclear Dept. CJP #592-313 (name) (repair organization's P.O. no .. job. no .* etc.)
  • Foot of FUttorwxx3 Road. Hancocks Bridge, NJ 08038 (address)
2. Owner Public SeJ;yice Electric an:'l Gas Co.

(name) Foot of art:tonwocx:l Road. Hancxx:ks Bridge, NJ 08038 (address)

3. Name. address and identification of nuclear power plant Sa1em Nuclear Generatirg station Unit #1 Foot of Buttorw-xx'J Rood, Haooy:ks Bridge. NJ 08038
4. System Fire protection Nuclear Class II
5. a: Component repaired. modified or replaced lFP ..........-1.,.4_,,.8'---'V""al-..v...,e..___ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _..,.__ __

b: Name of manufacturer ---VJ~1:1U----------------------------------...,...-- c: Identifying nos. ....o...0....3....9~---- NIA NIA 1973 (mlr's. serial no.) (Narl.Bd.No.) Qurisdictional no.) (other) (year built) d: Construction Code A.SME III 1 Q71 W l 971 WA 2 AN.SI B31. 7 1969 F.miitiH70 Add. PS ~-5043 (Code Case(s)) (Code Class)

6. Section XI 1983 _ _....SJ...nme
                                                                                                                     .......-r.-8..,3.___ _ _ _ _ _ _ __                                                 NIA (edition)                                                                      (addenda)                                                      (Code Case(s))
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 N.._V=A_ __

(edition) (addenda) (Code Case(s))

8. Applicable edition of Construction Code under which repairs, modifications. or replacements were made: *1969 *1970 N/A
                                                              *ANSI B31. 7/ASMF. III 1971 Fd. W71 Add./ (edition)                                                                           (addenda)       (Code Case(s))
9. Design responsibilities PSE&G PS Spec 72-5043
10. Tests conducted: hydrostatic O pneumatic 0 design pressure [)Ir* pressure 47, 3 psi Code Case(s)_=N_/=A~-----
11. Description of wo..X Install ed. new seat in valve by welcliJJ3, replaced disc valve boltil'XJ (use of additional sl'leet(s) or sketch(es) is acceptable ii properly identified)
  • am flarqe holtirq.

12.Remarks -~WOiui;r.k;;A....~Qr:rl.l,l,l.~e~r......-41#~*-==9~2~0~5u1~0w0~9~R.___ _ _ _ _ _ _ ___.,~..oc;.,if~j~c~i~ex:¥&~<-.....&:R~epc...,.~rt:......._~#~:._.SM0 ......."-9~2~-~5~7L7.!__ _ _~ Design OlaD;1e Package #: N/A Rev* N/A SHD 92-559 See attad'led pages for Pescription of Replacement. Hydrostatic test not performed CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102. current ecition. Certificate of Authorization no.

  • 36 to use the "NR" stamp expires oct. 3, . 19 94 Date t 0 - .S- 19 ..£2__. Signed_ _ PSE&G

___ Co.__ -Nuclear _ _ _ _Dept. _ _ _ __ Prirx:ipal Erl3r (repair organization) (authorized representative) (tide) CERTIFICATE OF INSPECTION _I, the undersigned, holcing a valid commission issued by The National Board of Boiler and Pressure Vessel lnspedors. and certificate of competency issued t: the state or province of New Jersey and employed by Arkwri t Mutual Insurance cb of MA have inspected the repair, modification or replacement described in this report on V and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty. expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. ate lo- I J , 191 ~. Signed ~/ ~ (1nspeetor) {'"*" /. Factoz.y Mutual System Commissions_,i./""""*_.rJ.,,_....,_7 >'------------ (Nad.Bd.No.(induding endorsements)state or provin~ and numbE This form may be obtained from The National Board of Bol!erand Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NE Re

Page _A_ of _1_ FORM NR-1 ~'rl'A$HMENT Code Job Package No.: 892-313 Work performed by: Public Service Electric & Gas Co., Nuclear Dept. 9: Owner: Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 Public service Electric & Gas Co. Foot of Buttonwood Road, Hancocks Bridge, NJ 08038

3. Location: Salem Nuclear Generating Station Foot of Buttonwood Road, Hancocks Bridge, NJ 08038
4. system: Fire Protection Nuclear Class: -==----- II
    ==============================================================================

ID of Component Replacement:Disc Name of Manufacturer: Velan ~~---------------------~------------------------

                            --~.........."--------------------~------------------------~~

2737 N/A N/A N/A__ N/A N-:-o~=--::---;---:=-:--~~----- Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: ASME III 1971 Edition W71 Addenda, Code Class II Code Cases: N/A_ ----- ID of Replacement: =B~o=n~n=e~t--=S~t=u=d=s:.___~~----------~--------------------~-- Name of Manufacturer: *---:-::~=---~~~:-:--'.~~~--:7'""'.'"=--~~~---:-:-~~~--~----~- Velan N/A N/A N/A N/A N/A =N7'-o==-"'.=--:-'"'.::"":"'-~,,........- Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: ASME III 1971 Edition ~ Addenda, Code Class I I Code Cases:N/A

    ==============================================================================

ID of Component Replacement: =B~o~n=n=e~t"--'N~u=t==s*~------------------~~~~~~~-- Name of Manufacturer: _...... Velan

                                 ......................~----~--~~~~~~~~------------~----~~--
 ~ N/A                            N/A                          N/A        N/A          ~N~o-----------=-------
 ~:=~~~-~~ ~     Nat'l. Bd. Jurist No.                          Other     Year Built       ASME Code Stamp'd.?
  . Replacement Const. Code: ASME III 1971 Edition W71 Code Cases: N/A Addenda, Code Class II ID of Replacement: .~F=l=a=n~g~e=-:-=S~t~u=d=s~-------------~----------------------------~~~

Name of Manufacturer: Allied Nut & Bolt Co.

                             =-=-=-=~"-"-=--------=---=-"-'~---~~--~~~~~~----~--~---

N/A N/A N/A NIA _ _ N/A ~N~O.__*-----,...---------~ Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: ASME III 1977 Edition ~ Addenda, Code Class ~ Code cases:N/A

    ==============================================================================

IO of Component Replacement:~F=l=a~n~g~e"--'N~u=t~s~------~~~~~------------------- Name of Manufacturer: ->'A=l~l=i=e=d"-"N~u=t=--~&--=B~o~l~t~C~o~*----~------------------------- N/A N/A N/A N/A__ N/A _N_o~--...,,.--~-~~~ Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: ASME III 1977 Edition S82 Addenda, Code Class l___ Code Cases: N/A ID of Replacement: Name of Manufacturer: Serial No. Nat'l. Bd. Jurist No. Other Year Built ASME Code Stamp'd.? Replacement Const. Code: Edition Addenda, Code Class _ Code Cases:

  • ===========-============================================================='!=====

FORM NR-1 REPORT OF REPAIR f,ia MODIACATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1

                                                                                                                        - Nuclear Dept.                                 a.JP #592-316

(- ~*1 P.O. no. job. no.,etc.1 08038 1-.!drea)

2. Owner _ _.... Pllb..==l""i=c'--=Serv=-'-=ioe=-'El=ectr==i=c'-=arrl='-Ga==s=--Co;:;;.=."-'- - - - - - - - - - - - - - - - - - - - - - -

tnameJ Eoot of ButtonwoOO Road, Hancocks Bridge, NJ 08038

3. Name, address and identification of nuclear power plant Salen Nuclear Generatin:J station Unit #1 Foot of puttoillrlOOd Bead, Hancxx:ks Bridge, NJ 08038
4. System O)enjrpl Volume Control Nuclear Class II
5. a: Component repaired, modified or replaced_...l...,C.._~_,,._,._,a;-coc..~2~3~2--Pi-'..,pe~~Gui==* de=----------------------

b:Name of manufacturer _ _~~ll.lo.Z..------------------------------------ c: Identifying nos. __N..,,,.....IA~-------~N~/~A~----------'N...,,.l ......A...._______~N""/~A~------=1~9_7_3_ _ __ (mfr.'* MliaJ no.) (Nel'I. Eld. No.) Ourildictional no.) (olher) (yNI built) d: Construction Code ps SiJHX)li: srec 69-6445 NIA 2 ANSI B31. 7 1969 :Edi1l"'"1970 Add. 1ac1~ (Code C:U.(s))

6. Section XI 1983 Sumrrer 8 3 N/A (edition) (addenda) (Code Cue(*))
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 =N.._/=A=----

(edHlonJ (addendmj p,de C.S.(S)l

a. Applicable edition of Construction Code under which repairs, mOdifications, or replacements were made. ~~~*
                                                                      *69-6445/ANSI B31. 7 1969 Fd. 1970 ~l (odHionJ                                                                  (addenda)         (Code Case(sJ)
9. Design responsibilities--1:::=;.ai.,:a....__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
10. Tests conducted: hydrostatic [J pneumatic a design pressure a pressure psi Tarp. N/A **Other
11. Description of work Perfonnerl weld repair to pipe Sl~rt. arrl replaced pipe guide.

(UM cl llddttional ~(1) °' IU!d\(") 11 acceptable K ptoperty identified) -~~~~~~~~~-

12. P.emarks: _ ___,Wo-....r~kA........,.Qrrj..._..~e.r__,j~*-9.,,,,..2~0~5~1.6~0w9~4L..-_ _ _~---~-~---------~-------~-~-

[lefjciency RefX>I+/- j: SMD 92-576 CERTIFICATE OF COMPIJANCE We ~rtify that the statements made in this report are correct and the reparr, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. ~ 6 to use the "NA" stamp expires ll' !9--9/r.. , Date*~/.30 I 19,9._l, &gned PSE&G ce. Nuclear !:q>t. (repair 0<~icn) Q.t _{,.yt_ (authoriad iapr~I Prine~ l Q-gr CERTIACATE OF INSPECTION I, the undersignttd, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by i t Insurance Co of ~ have inspected the repair, mOdification or replacement describe in this report on , 19~and state that to the best o IJy knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-f02, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal ~roperty damage or a loss of any kind arising from or connected with this inspection.

                                                      ~                                 ~                      .                                               Factocy Mutual system Date                          , 19_27 Signe                         ~~                                                          Commissions          l.J6'72'66             11-.r 1(2:2}{

(Authorized lnspectorj (Nllll.Bd.No.Qncludln; endcMwmenls)llate 0t piovince and number) may be obtained from The National Board of Boiler and Pres:Sure Vessel Inspectors, 1055 ()upper Avenue, Columbus, OH 43229. NB-81 Rev.6

FORM NR-1 REPORT OF REPAIR rA MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1

1. Work performed by PUblic Service Electric & Gas Co. - Nuclear Dept. CJP #592-317 (name) (repmir "'9anizatlan'1 P. 0. no. job. no.,etc.1 Foot of Buttonwood Road, Hancocks Brid:Je, NJ 08038 (addr8ss) 2.0wner_ _~Pub=-=~l~i~c:........;:Serv=--='"'--'i~ce-=-_El.:...;;;...;ectr~'"'--'i~c-an:l.=.:;.;;.._;,Ga....:..:.o.lS---"Co~.-------------------------

(name) Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 (mddr9a)

3. Name, address and identification of nuclear power plant Salem Nuclear Generatiig station Unit #1 Foot of Buttonwood Road, Hancocks Bridge, NJ 08038
4. System Safet;y Ins,pection Nuclear Class II
5. a: Component repaired, modified or replaced __1SJE3~~~1=2~Sa~~=e=cy=w-_In=J.,..'=ect~=i=on~~Punp~.__-----------------

b: Name of manufacturer_ __.Pa~csc1_*_f_i_c'-"'Bmp__,._,.________________________________ c: Identifying nos._~t\ IA...___ _ _ _ _ _ _....,N,,_/A.....___ _ _ _ _ _ _ __..N.,.._/..._.A._________.N~/-=A,,,__

                                ........                                                                                                                       _ _ _ _-=19~7"-0:::;_____

(mfr .'1 Mfial no.) (Nal'I. Bet No.) Qurl8dic:lional no.) (olhefl (yMt buiH) d: Construction Code ANSI B3L 7 1969___1.._97.. _0.. . ____ N/A 2 ANSI B31. },dliLQ67 Fd. ladclendal (Code CUe(a)) (Code Class)

6. Section XI 1983 SUmmer 83 N/A (edHlon) ~m) (Code C-(111
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 -'S8==3__ N/A (edHlan) (~ ~ Cne(sj)
8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: -*-- ~ 1970 N/A
                                                                         *ANSI, B31. 7/ANSI B31.1 1967 Fd.                                        <Cod-l     ledltionl      (addend-I          (Code Case(*))
10. Tests conducted: hydrostatic a pneumatic a design pressure a pressure NOP psi Terp. N/A *
11. Description of work Perfonned weld repair on flarge face.

_ _P.e_m_a-rk_s_: =:=:=::wa::r.:k::Ord:::er:==#====9:1:0:6:1:a:o:a:3========================================================== Deficiency Report #; SMO 92-560

                         *System Insetvice Test Performed at NOP.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. to use the "NA" stamp expires Oc:t. , 19--94-. 36 31 Date '1 - I " 1 9 , h Signed "R;E&C ca, Nuolear Ik?pt. (repair oiganlnlion)

                                                                                                                     ..e/b,. ,e.,_ L#'

(authorized ,.~) PEim~ )

                                                                                                                                                                                         ~         0 CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of                   New Jersey and employed by                                           Arkwri t Mutual                                            Co of      MA          have inspected the repair, modification or replacement describe in this report on                                                       , 19          and state that to the best Of my knowledge and belief, this repair, modification or replacement has been made iri accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date Cj//le ,19tjj;Signed ~~(. ~ Commissions 11lf'!fJ'ry Mutual System (Authorized lnapec:lor) * (Nall.Bd.No.pnetuding endonem*nl*)-e or province and number) I

  • form may be obtained from The National Board Of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NS.SI Rev.6

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION fJ OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 Worl< performed by Public Service Electric & Gas Q:>. - Nuclear Dept. CJP #S92-318 Rev. 1 Iname) ,._,, organization'* P. O. no. fOb. no.,ett.1

  • Foot of Buttonwood Road, Han::ocks Bridge, NJ 08038 (adclrea1 2.0wner _ _ _Pub __l_i_c_Seiv __1_'ce __El_ectr _ _i_c_*_an:l _ _Gas _ _a:;,_.________________________

(name) Foot of Buttonwood Road, Han::ocks Bridge, NJ 08038 (add-)

3. Name. address and identification of nuclear power plant Salem Nuclear Generati.rq station Unit #1 Foot of Buttonwood Road, Hancocks Bridge, NJ 08038
4. System Residual Heat :Removal Nuclear Class II s a: Component repaired, modified or replaced _ _,1RHE3=-==;:;__---=Hea=o=.t;:;_~==-=dwq==--"'-'er'-=------------------------

b: Name of manufacturer Er'x:1ineers an:l Fabrications Inc. c: Identifying nos. S-15860-C N/A N/A N/A 1969 (mfr .'s N<iaJ no.) (Na!'I. Bd. No.: Qurildictional no.) (olh*rl (Year built) d* Cons:*uct.ion Code WE Spec G676454 Rev. 1 1967 N/A 2 ANSI B31. 7 1969 Ecidlt*oil.970 Add. (adoon<la) (Code Cuet*ll (Code Class) 6 Section Xl 1983 SUmmer 83 N/A (edttion) (addenda) (Code Caae(1))

7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 _N~/_A_ __

(edition)

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: -*--
                   ~    E Spec. G676454 Rev. 1 1967/ANSI B31. 7 1969 F.d. 1970 ~'                                                                         1ec1ttooni   (addendaj
9. Design r e s p o n s i b i l i t i e s _ _ , P S ' - = E " " & G = - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
10. Tests conducted: hydrostatic a pneumatic CJ design pressure a pressure NOP psi Tenp. N/A *110t:her
 ,,_ Description of work              Replace heat exchanger bolting with upgraded bolting material.
12. Remarks: _ _Wo-'-"=r.=k~*..-Ord-=--c=er=--#~:~9~2~0.5=14~1=9"""'3'--
                                                           ...               _ _ _ _ _ _ _ _ _De_f_ic_i_*ency                     ___Repo     __      rt_#~:_SMD     _ _9_2_-5_9_5_ _ __

Design 01an::Je Package #: lS0-00303 Pkq. 1 Rev. N/A See attached pages for Description of Replacement. N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair. modif1cat1on or replacement of the items described above conforms to Section XJ of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. to use the "NR' stamp expires Oct. , , 19--94-.

  • 36 3 Date : '!fl ief/2-. Signed PSE&G eo.-Nuclear (repair ~*Ziiiion)
                                                                                                   ~*                 Q *:l "14~1 (aulhorlzed ~J Pri.rrip.31 Engr (UUeJ CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure yessel Inspectors, and certificate of competency issued by the state or province of                  New Jersey and employed by                                        Arkwright MUtual Insurance *Co of      MA . have inspected the repair, modification or replacement describe in this report on                                        ~/                , 19~d state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section Xl of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any person I injury or prope~amage or a loss of any kind arising from or connected with this inspection.

Oate  ?~/~ ,19'JYSigned { ~ Commissions ~Mutual system (Authorized ln1poc!Olj (Nall.Bd.No.Concluding er>do<semenls)llllle Of province 111\d numbe!) may be obtained from The National Board of Boi'ler and Pressure Vessel Inspectors; 1055 Crupper Avenue, Columbus, OH 43229. NB-al Rev.6

FORM NR*1 REPORT OF REPAIR :J MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) ~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER ?UNTSPage l of l Work periorme:::: by pi1bl j c Send re Electric & r..as Co. - Nuclear Dept. C? *591-325 (name)  :-epai*  ::n;ar.=ion*s P.O. no ...oo. "O .. etc.) Fcxrt: of Buttorn.rxx3 Rrad, Harxxr;ks Bridge, NJ 08038 (address)

2. Owner pqbl ic Service Electric ard Gas Co.

(name) Foot of B.lttonwocxl Road, ~ Bridge, NJ 08038 (address)

3. Name. adct'ess and identification of nuclear power piarrt Salem Nuclear Generatirg statiai. Unit #1 Fo?t of Bnttanwcxx1 Brad, Harxxr;ks Bridge, NJ 08038
4. System Reactor Ctx>l ant Nuclear Class I
5. a: Componen~ :-epaired, modified or replaced ... 1....

PS2__ a'--'v....a_l~v~e~--------------------------- b: N a m e o f m a n u f a c r u r e r _ - - - ¥ - c . i . . a . 1 . . L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - c: Identifying ~s. 176 N/A N/A N/A N/A (mfr's. serial no.) (Nar:.Bc.."Uc.) Ourisdictional no.) (or-er) (Year built) d: Cons!:"'..ictJcr Code ASME Ora.ft Ox3e far Pmnps & Valves 1968 Frl. 1970 J,dd. WA----------- ANSI B31. 7 1969 ~itiqg7Q Add. (addenda) (Code Case(s)) (CooeCass)

6. Section X' 1983 _ _._.Si._.nmre
                                                                                               .......-..r__.8...3....___________                                                 N/A (edition)                                                          (addenda)                                                  (Code Caseis))
7. Applicabie edi:*.:>n of ASME Code Section XI under whrc:'l repairs, modifications, or replacements were rna0e* 19E3 S83 NJ../=A_ __

(eer.cr (addenda; (Code Case(s))

8. Applicabe edi:*:in of Construction Code under whid1 repairs. modifications. or replacements were made: *196~ 1970 N/A
                                                          *ANSI 831. 7/ASME Draft Code                                                         (edi:io-:          (addenda:          (Code Case(s))
9. Design resporsibilities PSE&G for Pl1mps & Valves 1968 F.d. 1970 Adi.
10. Tests cordUd:?.:. hydrostatic D pneumatic  :.... design pressure D** pressure N/A ps Co:e :.=._se(s)---'N~/A=-=--------

Replaa:rl valve l:x:!nnet S/N 5912327-1 aOO boltirg. (use of additional sheet(s) or sketch( es) is acceptabie if ::r.ioerty !Dr.l~e:'

12. Remarks Deficierqz Rep">rt ;f* SMD 91-428 CERTIFICATE OF COMPLIANCE We certify tt-a: the statements made in this report are corn:d and the repair, modification or replacement of the items a:sdbed above conforms to Section XI of the ASME Code and the NatioFlal Board rules as def:ieC m the publication NB-102, current edition.

Certi~te of Ault'O"ization no. 36 ID use lt!ie "NA" stamp expires oct. 3, , 19 94

           ~                                            PSE&G Co.-Nuclear Dept.                                                                                        Priocipal Ergr Date tL -    dl ov       19,~. Signed. _ _ _ _ _ _ _ _ _ _ _ _ __

("'=Cair organization) (authorzec ~prese"'.;a:-.e ~tit1e} CERTIFICATE OF INSPECTION

 .1. the unders-;nec holding a valid commission issued by Tne National Board of Boiler and Pressure Vessel Inspectors irC ::.ertificate of ccm;::etency issued by the state or ::rovirce of         New Jersey              and err.pioyed by                               kwri t Mutual Insura:.ce Co of       MA               have inspected the repair, modificalior, or replacement described in this report on                                - Z.                      are sta!e that to the best of my k:':cwlEoge and belief, this repair, modification or replacement has been made in accordance wi1h Section X :t :!"e ASME Code and :he National Board rules as deiined in the publication NB-102, rurrent edition. By signing this certificate, neither the lnspecror nor hs ~;lloyer makes ;riy warranty, expressed     or impfied, concerning the repair, modification or replacement described in this report. Furthermore. neither ~e Inspector nor his employer shall be le in any n-.anrer for any personal injury or property darr..age or a loss of any kind arising from or connected with the ns;:EC!ion.

ate '? -';.-~ ,19q 'V. s;,,ooqiYr;u./ { ~ Comm;,.;o"' NJ':f!Y M.rtual Sysbm / (1hspector) * (Natt.8d.No~ndudif1' Focroements)state C7 ;:>rovnce and number) This form 1112)' be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Cruppw Avenue, Columbus, OH 43229. NB-81 Rev 6

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTAUATION OF REPLACEMENT(S) ft TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1

    , . Work     performed by        Public Sezvice Electric & Gas Cb. - Nuclear Dept.                                                                        CJP #S92-329 Foot of art:tonwcx:xl Road, Harx:lx:k.s Bri?;Je, NJ 08038
                                                                                                        ,_,                                                      ' - ~*1             P. 0. nc. fCIC> no .* - ..

(-'-)

2. Owner Public Service Electric am Gas Cb.

(name) Foot of art:tonwcx:xl Road, Hancocks Bri?;Je, NJ 08038 i--1

3. Name, address and identification of nuclear power plant Salem Nuclear Generatirg station Unit #1 Foot of aittorrwoc9 Rbad, Hancocks Bridge, NJ 08038
4. System :Reactor COolant Nuclear Class I s a: Component repaired, modified or replaced ___1PR2==--V,..:..;al=v..._e=----------------------------

b: Name of manufacturer c.cpes-Vulcan c:ldentifying nos. 6910-95001-164-1 N/A N/A N/A 1968 (ml! .'s Mrlal no.) (Nan. Bd. No.) Qull9diclioNI no.) (olhef) (YMr buUI) d: Construction Code W E-S,pec G676270<--___,,,1""'9-"'6""-6_ _ __ NLA 1 ANSI B31. 7 1969 Flibioti970 Adi. !addenda! (Code Cue(a)) (Code Cius)

6. Section XI 1983 SUnmer 83 NLA (9dblon) (addende) (Code C...(a))
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 NLA (ldlllon) (addenda) PD c-tiii
8. .Applicable edition of Construction Code under which repairs, modifications, or replacements were made: -*-- 1969 1970 NLA
                                                                           *ANSI B31. 7/'fi E-Spec G676270-196~1                                               (ed111on1     (add~            (CodeC-1911 ll. Design resp0nsibilities. _ _.P$E&G,_..,=,,,,_*- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - . : ___
10. Tests conducted: hydrostatic a pneumatic a design pressure D pressure NOP ?Si Tetp. N/A *Other
11. Description of work ReI>laoed cage assembly an:1 performed weld repair on plU].

(UN ol llddttionaJ llhffl(a} O< -ch(*) ii ~ I p<opel!y identified) "'"'*"*" Work Order #: 920207007 Deficiency Report #: SMD 92-614

                          ~ign Olarge Package #: N/A                                                          Rev. N/A See attached pages for I:escription of Replacem:mt.                                                                   N/A
                          *SYstem Insezvice Test Perfonned at NOP J...i dT" CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition.

Certificate of Authorization no.

  • 36 to use the "NA" stamp expires Oetx:? , 19--*.
                                                                           ~.-Nuclear Dept.                                 a ..;/. f;.v,~                            Prioo~

1 Date .Pµ/ 19,C/2. Signed PSE&G (r~ OfV&l'lizallon} 0 {a&Ahaltz9d ~} ) ED3r CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boller and Pressunt yessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwrigh,t Mutual Insurance Co of MA have inspected the repair, modification or replacement describe in this report on ~ -Id , 19:£2"and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Date f-{D/ ,1/fJ-s1gned ~~-zn.lJ -z*. /

                                                                                             ~
                                                                                              /          / .                                      ~cto~ Mutual Commissions--'-AJ""---(J"--'JJ.._._Z_J _ _ _ _ _ _ _ __

system

                                                                               !Authorized ln1pectCll)                               (Nall.Bcl.No.Qncludinv *ndo<Mment1)11at*    °'  pr~     and nurnbeo)
  • may be obtained ~m The National Board of Boiler and Pressure Vessel Inspectors, 1055 ~pper Avenue, Columbus. OH ~- Nl, Rav.6

FORM NR-1 REPORT OF REPAIR ~ MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 i Work performed by Public Service Electric &. Gas O::>. - Nuclear Dept. CJP #S92-333 (n&mel I -

  • organ1utron'1 P C no. fOI> no .. ett.i Foot of Buttonwoo:i Road H.ancocks Bri e, NJ 08038

(&ddr-)

2. Owner _ _ _ Pub

__l_i_c_Serv _ _i_oe __El_ectr __i_c_arrl _ _Gas _ _O::>_._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ (name) Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 (addr-)

3. Name. address and identification of nuclear power plant Salem Nuclear Generatin] station Unit #1 Foot of Buttonwood Road*, Hancocks Bridge, NJ 08038
4. System Containment Spray Nuclear Class II 5 a: Component repaired. modified or replaced Pipe spool between valves 11CS6 arrl 11CS44.

b: Name of manufacturer _ __.Ke""'"'... 1....1...,cgg~.,_------------------------------------ c: Identifying nos. _ _ ________~,,,,,,__,,_._

                               ~.,._/~A                                     N/A _ _ __                                     NLA                                 NL'.A                               N/A (mfr.'s..n&;no.J                     (Nal'I. Bd. No.1                              ijurilldiclon&: no.)                           (cl her\                            (yea* buittl d Construction Code           ANSI B31. 7 1969                                  1970                                 N[A                                                                      2 ANSI B31.1 1967                         1e11n1<>nJ                              (addenda)                                                  (Code Cue(S)j                              (Coce Class) 6     Section XJ                              1983                                                       summer            83                              N/A (DCMron)                                                  (addenda)                                                        (Cod* Case(*))
7. Applicable edition of ASME Code Section XI under which repairs. modifications. or replacements were made: 1983 _S_8_3___ N/A (edHlonl (add and.;

8 Applicable edition of Construction Code under which repairs. modifications. or replacements were made: -*-- 1969 1970

                                                                                              *ANSI B31.7/ANSI B31.1 1967fCod*l                                           (edHionJ      !addenc1a:
9. Design responsibilities.--'=~~-------------------------------.--..,-----.,-----
10. Tests conducted: hydrostatic It: pneumatic a design pressure a pressure 290 psi Tenp. N/A ( Q.,... ICI'\ ~, I:. ...
11. Description o! work Ferformed weld repair to pipe sp;x>l 1CS6 ard 11CS44 valves.

(uoc ol addtttona! .r-t(a) o* tketch(n: 11 acce~ I properly identified)

  • ~~~~~~~~~-
12. Remarks. __Wo_,_,',,.....,rk._.~ord~.,,,er"""'-_#......._:_,9=2...,,0,,._,6=0=3<..:1....,6=5'------------------------------

Deficienqy Report #: SMD 92-630 CERTIFICATE OF COMPUANCE We cenity that the statemems mace in this repon are correct ano the repair. modif1cat1on or replacement of the items described above conforms to Section Xl of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. to use the "NR" stamp expires Oct. , 19--94--. 36 31 Date 7/t 19.,ib Si~ned ~E&G CG.-Nuclear ('*PAl' orgaruzalionJ Dept. Q .J. iw /r (*u1hor1zed "'P'~) Principal EnJr

                                                                                                                                                                                            ~ltlei CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure yessel Inspectors. and certificate of competency issued by the state or province of                           New Jersey and employed by                                            Arkwr1 t Mutual Insurance Co of      MA         have inspected the repair, modification or replacement describe in this report on                                                                      , 19 !? Z. and s1ate that to the best of my knowledge and belief. t"iis repair, modification or replacement has been made in accordance with Section XJ of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty.

expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore. neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

                                                               ~                                                                                   .          Factory Mutual System Date      ,               , 19 2'? Signed                          ~~                                                        Commissions            A/d7&'?;h Al \:LID.:;? Y (Au1t>orized Inspector)                                     (Nall.Bd.No.pncluding endo<Semonls)slato or prO'o'iC>Ce and      numbe~

rm may be obtained from The National Board of Boiler and Pressi.Jre Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB*81 Rev.6

FORM NR*1 REPORT OF REPAIR ~MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page l of l

1. Work performed by pi ihl i c Sezvi ~ Electric & C..as Co. - Nuclear Dept. CJP #892-335 (name) (repair organization's P .0. no., job. no .. etc.)
  • Foot of 'B!Jttont.a"Xrl Brad, Hancoc:ks Bridge, NJ 08038 (address)

(name) Foot of B!Jttonwrxrl Road, Hancoc:ks Bridge, NJ 08038 (address) saiw..ol..,em....._.....Nu~C"!.,.l,..ea.....,..,r.........,Genera;.,.,._._...,..,t iDJu;i._..sta..__...,ti~*a,.,,n._.____,,,Uni,,,_.,,...,t"--"#IL;l:::_______ 0

3. Name, address and identification of nuclear power plant _ _... .....

Fcx>t of BtrttoJ1WOCrl R0ad, HallCX)Cks Bridge, NI 08038

4. System Chemical Volume Chntrpl Nuclear Class II
5. a: Component repaired. modified or replaced ....Po...i"!pe,......_.Spoo"'t"""""""'l__.l_-0Jl__,...,,C...-~1 ....S~-----------------------

b: Nameofmanufacrurer_-1;....:.ln'.l~i.,J-----------------------------------~ c: Identifying nos. ~N.,,,1.,...IA----- N/A NIA NIA 1976 (mfr's. serial no.) (Narl.Bd.No.) Ourisdictional no.) (other)

                                                                                                                                                                                                  *                                                  (year built) d: Construction Code        ANSI BJ l 7 1969                                   ]970                                                                                   TVA                                                             II ANSI B31. l 1967 (edition)                                            (addenda)                                                                             (Code Case(s))                                                     (Code Class)
6. Section XI l9SJ SUltlll¥?r 83 WA (edition) (addenda) (Code Case(s))
7. Applicable edition of ASME Code Section XI .under which repairs, modifications, or replacements were made: 1983 S83 N,.../'"""A..__ _

(edition) (addenda) (Code Case(s))

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: *1969 1970 N/A
                                                                                  *ANSI B31. 7/ANSI B31.l 1967                                                                                (edition)                        (addenda)                 (Code Case(s))
9. Design responsibilities ....Es.f~i---------------------------------------
10. Tests conducted: hydrostatic D pneumatic D design pressure D** pressure 1,:; psi Code Case(s) _ _.ij"Y/'"'A..________
11. Description of work Repaired welds an elha.z an spool lCVC-15 that was rgnpved for (use of additional sheet(s) or sketch( es) is acceptable if property identified)
  • maintenance comrenience 12.Remarks: ---~.,......,~~~lf"T---:;J.,.blol.1W-1~r1-t._....~;J-64;~'-'-~~~~.......~..._.~~~"'"':t..........._~#~*.._.1'~"'A~~~~~~~~-

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization no. 36 to use the "NR" stamp expires Oct. 3, , 19 94 19, 9 2-. Signed_ _ PSE_&G_-_eo_._-_Nu_c_l_ear __Dept _ _*_ _ Principal ~. Date/~ - I  ;;> (repair organization) (authorized representative) (ti~e) CERTIFICATE OF INSPECTION _I, the undersigned, holding a valid commission issued by The National Board of Boiler and Prei;sure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by ' Co of MA have inspected the repair, modification or replacement described in this report on and state that to the best of my knowledge and belief, this repair, modfication or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty,

  . expressed or implied, concerning the repair, modfication or replacement described in this report. Furthermore; neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
                                                                                /" /                    J                                                                                    Facto:cy M..ttual system
            /0 - /          ,19q v* . Signed                ~ 't' * ~

(lnSpector) Commissions /l.J:J'J1J . (Nad.Bd~.N-o-.(i~nd-ud~ing~e-nd-o-rse-m-en_ts_)_st-at-e-or-p-ro-v-in-ce_an_d-nu_m_be-r) This form may be obtained from The National Board of Boller and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus, OH 43229. NB-81 Rev.6

FORM NR-1 REPORT OF REPAIR I! MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1

     ,     wor1<   pertormed by        Public Service Electric & Gas Co. - Nuclear Dept.                                                                      CJP #592-339 0

__Foot ___O_f"-""-Buttonwood ______Road_---',_Hancocks_.;:_,:; ____ Bri?Je_'~..._-,,_, _NJ_, __08_0_3_8_________'__ __-__*_**_P_._._"°_*_iDb_"°_.._.._c*._*

  • .-.ai 2.0wner~~-Pub _ _l_1_*c_Sexv~ __ioe __El_ectr~~1-*c_an:l~~Gas~~Oo __*--~------------~-~---~-~
                                                                                                     ~)

Foot of Buttonwood Road, Hancocks Bri?;Je, NJ 08038

                                                                                                    ,__j
3. Name. address and identification of nuclear power plan1 salem Nuclear Generatin:J statim Unit #1 Foot of Buttonwood Roaci, Hancocks BriQ:ie, NJ 08038
4. System ~ety Injection Nuclear Class II
5. a: Component repairea. modified or replaced __V..=..;a.l=v..:....::::eo-=1:...:4:.::::SJ=-=54"-=----------------------------

b: Name of manufacturer ___Vi~el=an~------------------------------------ c: Identifying nos. N/A ~--=N~/=A.__ ________ N/A N/A

                                                                                                                    .......,..,.:..:__~-~--...-....-=------~~1=9~6~7:;...__ __

(mfr .'s Mrial no.) (Nm'I. Bel. No.) Quri9diclional no.) (othefl (yMI b\rift) d: Construction Code WE ~76258.__=---'=----- N/A N/A N/A (edlllon) (9ddenclal (Code ca.(*)) s: Section XJ 1983 summer SJ N/A (9dftlon) ~ (Code C-(91)

7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 -=N""/-=A-=----

Pldl c::a.c-11

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made:
  • N/A
                                                                                                  *Westin;jloose E Spec.                           !Code>
9. Design responsibilities J?SE&G G-676258
10. Tesu conductecL hydrostatic a pneumatic a design pressure a pressure N/A psi Teip. N/A **Other
11. Description of work Weld 7/8 11 fillet weld in lieu of existim threads on yoke-bonret
  • joint.

1..:. Ramancs: _ __:.;Wo=r....,k--=Ord~er=----'#._,:,__.9=1=1""'12=60,,,.,2...,0~--------------------------- Deficiercy Report #: SMD 92-646

                           **System Inservioe Test @ NOP/NOi' camACATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XJ of the ASME Code and the National Board rules as defined in the publication NB-102, current edition.

Certificate of Authorization no. to use the "NR" stamp expires Oct , , 19--94-. 36 3 Date Pis 19.9..2,.. Signed PSE&G OJ, aiGlear Dept. (19pAir ~ a ....t/Po?:vci (authorii9d ~) Prine~ ) ErxJr. CEA I IHCATE OF INSPECTION I. the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwri t Mutual Insurance Co of MA. have inspected the repair, modification or replacement describe in this report on , 19 and state that to the best of my knowledge and belief, this repair, modification or replacement has been made In accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any person I Injury or property damage or a loss of any kind arising from or connected with this inspection. Date <(- l ,19q i,, Signed {. Commissions 4tj~f~cy Mutual System

                                                                                  !Authoriz9d lmp9ctOI)                               (Nalf.Bd.No.(lncluding endo<Semwlts)llllle or p<ovince and numbet)
  • may be obtained from The National Board of Bot1er and Pressure Vessel Inspectors, 1055 Crupper. Avenue, Col~mbus, OH 43229. NB-81 Rev.6

FORM NR-1 REPORT OF REPAIR C MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) ~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 Wor~ - Nuclear r:ept.. pertormed by Public Service Electric & Gas Co. CJ"P #892-340 Foot of Butt.orrwoc:x:i Road, Hancc:x:::Jr.s Bridge, NJ 08038 F6ot of ButtoI'l'w'OOd Road, Hancocks Bridge, NJ 08038 1aaa.... 3 Name address and identification of nuclear power plant Salem Nuclear GeneratirxJ station Unit #1 Foot of Mt.onwood R@d, Hancocks Bridge. NJ 08038 4 System Reactor Coolant Nuclear Class I s a*~m~Mm~~~ed.m~ilied~~~a~-~~~~6-V~~~~~e------------------------------- b: Name of manufacturer Velan Valve Coxi>* c* ldentitying nos. 6381782 N/A N/A N/A 1967 (Nal'i. Bet No.1 Quri9dic:tlonaJ no.) (othef', (year buiftJ d: ~nstruction Code li E Spec. 676258~:Rev~~*~1~--- N/A 1 (9dllion) (edclenda) ICOOe Cesets))

6. Section XI 1983 SUmmer 83 N/A

(..SHion) (addenda) ~ C...(a))

7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 N""-'-/~A"----

(edlllon) (addenda) Pxle ~I

8. Applicable edition of ~nstruction Code under which repairs, modifications, or replacements were made:
  • N/A
                                                                                      *:h7 E Spec 676258 Rev. 1 (68) !Code; (9dttion) lllddendal
9. Design res~nsibilities......&.:w.i;.wo.2_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
10. Tests conducted: hydrostatic 0 pneumatic C design pressure a pressure NOP psi Tani>* N/A **Other
11. Description of work Bepl acaj stem arrl wedge and en1arge wedge guides by machining.

(UM ol loddttiona' ~(I) O' lli<atcll(n) is ..:;e~ W;>topelly iclenUfied) CERTIFICATE OF COMPLIANCE Section XI of the ASME ~de and the National Board rules as defined in the publication NS.102, current edition. Certificate of Authorization no. Date ; RIIs 19.!ll. Signed 36 I'GE&C es. to use the "NR" stamp expires Huolear Dept. r We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to

a. .Rol.vr.i J , 19-94-.

Pri.nci~ ~* (19:>alr oraaniZaJion) (aulhorUed "'PrHenla!Ne) *) CERTIFICATE OF INSPECTION I, the unde~signed, holding a valid commission issued by The Na:ional Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwri t Mutual Insurance Co of MA have inspected the repair, modification or replacement describe in this report on , 19 nd state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance wi Section XI of the ASME ~e and the National Board rules as defined in the publication NS.102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer

  • shall be liable in any manner for any pars injury or property damage or a loss of any kind arising from or connected with this inspection.

bate f-- // , tfZ 19 Signe <, Commissions µdj,CSf['i Mutual System IAulho<lzed ln1poctDlj (Nell.Bd.No.Qncluding endor.>aments)otate or piovince and number) may be obtained from The National Board of Boiler and Pressure Vessel Inspectors; 1055 Crupper Avenue, Columbus, OH 43229. NB*81 Rev.6

FORM NR-1 REPORT OF REPAIR iJ MODIFICATION 0 OR INSTAU.ATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 perlormed by Public Sel:vioe Electric & Gas Co. - Nuclear Dept. CJP #S92-344 (._,, or;aniza1oon'1 P. 0. no. JOO. no .*.cc. (llddlWU)

2. Owner _ _ _ Pub

__ l_ic_Seiv _ _i_*oe __El_e:::_LL_i_c_and _ _Gas __ eo_._*- - - - - - - - - - - - - - - - - - - - - - - Foot of Buttorrwood Road, Hancocks Bridge, NJ (name)

                                                                                                             )

08038

3. Name. address and identification of nuclear power plant salem Nuclear Generatirl;J station Unit #1 Foot of Buttorrwood Road, Hancocks Bri.d:Je, NJ 08038
4. System Reactor Coolant Nuclear Class II s a: Component repaired, modified or replaced l.RCEll - Pressurizer Relief Tank b: Name of manufacturer Westingha.lse c: Identifying nos Irl0662TK-l 61420 N/A N/A 1975 (mlt .'s Mrial no.) (Nmrl. Bd. Nc:i.J Quri8dk:tional no.) (yMr buitt) d: Construction Code ASME Sec. III 1965 N/A N/A 2 ANSI B31. 7 1969 ~l 1970 Al:Xl. !addendal fCode C:U.(1))
6. Section XI 1983 SUmrrer 83 N/A (lldttlan) (~ (Code C...(1))
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S83 N/A (lldltlon) (llddenda) Pde c:..(ol1
8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: ~ 1969 1970 N/A
                                                                               *ANSI B31. 7/.ASME                        sec. III 1965            (Code!       fedllion!     19ddendal
9. Design responsibilities __PS_E&G ______________________________ ___,_,=---------
10. Testa cond~cted: hydrostatic D pneumatic a design pressure D pressure NOP psi Tenp. N/A **Other
11. Description of work Machined :rupture disc seatirB surface.

(UM d 9dc!Hional "-1(1) Of -ch(n) s ..:ceplabie Wptop9lly idenl&d)

12. Remancs: _ _Wo_r_,k_Ord_er ......6_0_2_8_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

_ _.#.._:_9'""'2_1_00 Deficiency Report #: SMD 92-662

                            **System InseJ:Vioe Test Perfonned at NOP CERTIACATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Set:tion XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition.

Certificate of Authorization no. 36 to use the "NA" stamp expires  ::m* 3 , 19__g.i., Date 1/3fJ 19f/2_. Signed J?SE&G co. -Nuclear D?pt (} V (19palr OliAf'izallan)

                                                                                                                                       ~'Jf
                                                                                                                                     ~ ~)

Principal Fnp-. (Ulle) CERTIFICATE OF INSPECTION I, the undersigned, holding a valid oommission issued by The National Board of Boiler and Pressure Vpssel ln~pegtorsLand certificate of competency issued by the state or province of New Jersey and employed by Arkwr1 t Mutual ~ CO of MA have inspected the repair, modification or replacement describe in this report on , 19 and state that to the bes1 of my knowledge and belief, this repair, modification or replacement has been made in accordance with Section XI of the ASME Code and the National Board rules as defined in the publication NB-102. current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

                                                          .                            -/         ,.-                                                 _Factory Mutual system Date        7,_ 3 /         ,1{ih- Sign                  ~ {:- ~                                                       Commissions_~-'~1.L...-.~7~J""-----------

(Authori.zlld ln1pect0f) lf'Ull.Bd.No.pncludlng oodorNmonis)llat* °' p<ovince and numbel) rm may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Qupper Avenue, Columbus, OH 43229. NS-a1 FWY.&

FORM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT($) Ji TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of

  • ork performed by Public Service Electric & Gas Co. - ltlclear Dept. CJP #592-350
  • lnatne) (repair organization's P. 0. no. ,cc nL.JIC..
 *
  • Foot of Buttonwood Road, Hancocks Bridge, NJ 08038 (address) 2.(),yner~__Pub __l_i_c_Serv _ _i_ce __El_ectr _ _1_*c_arxi _ _Gas _ _Co_._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _~

(name) Foot of Buttonwood Road, Hancocks Bridge~ NJ 08038 (addrea)

3. Name, address and identification of nuclear power plant Salem Nuclear Generatin;J station Unit #1 Foot of Buttonwcxxi Road, Hancocks Bridge, NJ 08038
4. System Service Water Nuclear Class I:

12SW58 Valve

5. a: Component reoairec. modified or replaced .,,----===..:..;.=.;;;_~~...:::.._-~~~~~~~~--~~--~--~-------~

b: Name of mani..iacturer Masoneilan International c: Identifying nos. N-00113-39-2 N/A N/A rrtr.'s serial no.) (Nal'I. Bet No.) (jur'lsdiclcr.IB no.) IOlhell d: Construction Code ASME Draft Code for Pump & Valves --=19=-=68=--=Ed=.'--=1==9:...:7-=0:..-=.:Mi=:.:..*---=N:.:./c.=A ____2_ _ _ _ __ ANSI B31. 7 1969 ~tt"*870 Add. (addenda) (Code ::-.SJ)

6. Section XI 1983 SUimoor 83 N/A (edition) (addenclal (Code Caae(s))
7. Applicable editicr. of ASME Code Section XI u~der which repairs, modifications, 0t reotacements were mace*. 1983 883 _N..._/_A_ _

(edHlon) (addendaj

8. Applicable editiCt" of Construction Code under which repairs, modifications, or replao!n'lents were made:
  • 1969 1970
                                                                 *ANSI B31. 7/ASME Draft Code                                                                   (Ade> (edttionJ              taddendllJ
9. Design respon~!ities PSE&G for PLnaps & Valves 1968 Ed. 1970 Add.
10. Tests conductec hyc.-:>static a pneumatic a design pressure a pressure ~ilOP psi Terp. N/A **Other Description of wor1< Replaced valve bolting.

(UM ol addHional sheet(*) or skelctl (es) is llCCeptacle t :m>perly identlfied)

12. Remarks: _ __,wac::-::::rk~_,Ord=,,,,er=-...u#_,_:-=9=2=-06=2,,,_7'-'0=-=5~6=------------'De=f::.:1::.:'c::.:i::.:ency=""--::.:Repo~::.:rt:..::....-'"#-=-:--=-SMD=_9:..:2=--68-=..::..:5:___ __

Design Charge Package #: N/A Rev. ~r./A See attached pages for Description of Replacement. N/A

                            ** Svstem In.service Perfontied @ NOP CERTIFICATE OF COMPUN<<:E We certify that the stater"'lents made in this report are correct and the repair, modifi::a::ion or replacement o! T.e items described above conforms -c:

Section XI of the A.SME ~de and the National Board rules as defined in the publica::crr NB-102, c.urrent edilcn. Certificate of Authorization no.

  • to use the "NR" stamp u::iires Get 3 , , 19---94-.

36 Date 7/23 1s 9l. Signed J;5E&G Co.-Nuclear Dept (repair organizallon) 0.. JJ>c (,vc.6 (authortzec:t ...,..w itallft) Frioc:ip.31 Engr. (Ullal CERTIFICATE OF INSPECI 1ION I, the undersigned. hOlding a valid commission issued by The National Board of 8oDe< ilfld Pressure ,Vessel t'spectors, and certificate of competercy issued by the state or pr.>vince of New Jersey and employed by Arkwri~t Mutual Insurance Co of MA ha>..e insoected the repair. modification or replacement describe in trus report on J * ~ k , 1g 9Vand state that 1D tre best of my knowlecge and belief, this repair. modification or replacement has been mac& m accordance with &!ction XI of the ASME Code and ttie NHicrai Board rules as defined it'. the publication NB-102, current edition. By signing this certffiarte, neither the lnspecter nor his employer makes any ~ expressed or implied, concerning the repair. modification or replaeement described ir. :tnis report. Furtherm:re, neither the Inspector nor his ernp~er shall be l~e ~ ary m<¥iner :r any pe~I injury or pr~rty;amage or a loss of ar.iy kind arising from p~~ ~Wstem Date g' rlc .19?'-:- SignedL~ Z

  • l(;.,,,,(__ ;1_,J,____________

Commissions.---'/l.C-=._.,.=--Jo<.....:;

                                                            /.                       (Aulhorized lnspeclcl)                                     (Natl.Bd.No.l!Tduding endor.;ementsjstate e< P<OYinc:e anc::        nummi This form may be obtained from The National Board of Boiler and~ Vessel klspelctors, 1055 Crupper Jwnue, Columbus, OH 43229.

FORM NR-1 REPORT OF REPAIR. 3 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS Page 1 of 1 ork perfor:-.ed by Public Service Electric & Gas Co. - Nuclear cept. CJP #S92-352

  • (name) (TWC*I ::irganlZation's p. a. no. tob. no.,etc.)

Foot of B.Ittonwood Read, Hancocks Bridge, NJ 08038 (address) 2.0wner _ _ _P..Jb __l_1_'c_Serv ___ice __El_ectr___ ic_aJ'D__Gas _ _Co __

  • _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

(name) Foot of B.Ittonwood Road, Hancocks Bridge, NJ 08038 (addrea)

3. Name. address and identification of nuclear power plant Saleill Nuclear Generatirg station Unit #1 Foot of B.lttonwood Road, Hancocks Bridge, NJ 08038
  *. System              Reactor Coolant                                                                                                                                        Nuclear Class I I
5. a: Component !"9:laired, modified or reolaced. __6::..:5::..:2::..:2=XD=--'Rea==ct..:::.:::o=r-=Ins=-=:...::tnnnen=-===t=--=Irxli==*ca=t=lJ!J=*  :.::.o<.-TUb==irg=-=---------

b: Name of manufacturer _ _- - - = - P S = r . & G = = - - - - - - - - - - - - - - - - - - - - - - - - - - - , - - - - - - - - - - - - - - - c: Identifying nos. _ N/A _...,N.!J./'-"A"'-----------'==-~----'------=<-==----------=-;L..:;.-=--------...:::J.'-=---- N/A N/A N/A (mfr.'s serial no.) (Nafl. Bd. No.1 ijurisdiclional no.) (other) (year buih) d: Constructior ::Ode ANSI B31. 7 1969 1970 NLA II ANSI fill.l 1967 ~, jaddenda) t:ode Case(*)) (Code Class)

5. Section XI 1983 SUrmner 83 N/A (odttion. (addenda) !Cooe Case(*))
  ~     Applicable edi'.:on of ASME Code Section XI under which repairs, modifications, or replacements we:e made:                                               1983                 S83                 _N~/_A ___

(odttion) !addenda) (C.ode C..S..(sl)

8. Applicable edr:on of Construction Code i..nder which repairs. modifications, or replacements were made: _*__ 1969 70A N/A
                                                                                *AN.SI B31. 7/ANSI B31.1 1967 Fd.                                          Code)        1edll>cr..      (addenda)           (Code Case(s)I s     Design respor.sibilities--'PS=-==E=-=&G==----------------------------------------
 ~:i. Tests condue2d: hydrostatic                a       pr.eumatic a      design pressure         a        pressure          N/A psi ~* N/A                                **

Perfo:med. weld repair to Reactor Instnment 'I\Jbl..rq. (use cl addrtior.a; sr-t(1) or sketch(es) i1 acceptable tt property identified

2. Remarks: _ ___:.'W.:..::o=-=r=k=----=Ord===er=-...!.!.#....:.:-=-9=2=0=-9=12=0.::..:3::...;8=-----------------------------

teficiency Report #: SMD 92-694

                             **SVstem Inservice Test Perfo:aned at NOP/NOi' CERTIACATE OF COMPLIANCE We certify that    r-e statements made in this report are correct and the repair, modification or replacement of ~e items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, curr~t edi-.:on.

Certificate of Au~:>rization no. to use the "NR" stamp expires Oct, J , 19__..g4 ..

                                                                                                                                                       /

Date J>/S 19,qz.. Signea ISE&G Co -Nuclear Dept 1 - r organization) fLL. L..,..L (authorize ~) Frincipal Engr.

                                                                                                                                                                                           ~ttl*)

CERTIACATE OF INSPECTION 1, the undersignec. holding a valid commission issued by The National Board of Boiler and Pressure yesse1 rspectors, and certificate of competency issued by the Staire or province of New Jersey and employed by Arkwrl t Mi.Itual Insurance Co of MA '"l.Bve inspected the repair. modification or replacement describe in this report on , 19 and state that to the best of my knOWte:lge and belief, this repair. modification or replacement has been made in accordance with Sectio XI of the ASME Code and the National Board rules as cef1ned in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or impiied, concerning the repair. modification or replacement described in this report. Fur:iermcre, neither the Inspector nor his employer shall be liable ir :i_py manner for any person I injury or pro~rty?:l;mage or a loss of any kind arising +.'om cc connected witrl this inspection. (/ _.., / t-- r _ F~cto:cy 1'h.rt:ual System Date O '-") 1

                                    ,1e_']tSigned                                   C....
                                                                                   ~zedlnspec1o~

Commissions.~fl/..:......<J__:_J..:..7,,,,.}'------------ (NatL5d.No.lrciuding eudo*-*-)state or province and num~r) This form may be nbtained from The National Board of Bocler and Pressure Vessel Inspectors, 1055 ~Avenue, Columbus, OH 43229. NB-81 Rev.6

FOAM NR-1 REPORT OF REPAIR 0 MODIFICATION 0 OR INSTALLATCN OF REPLACEMENT(S) ~ TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR P:wER PLANTS l f l Page o Work pertorrrec oy pnbl j c Send cp El ec+/-ri c & C'..as Ca - Nuclear D?pt. CJP #592-360 (name) ~** 0';<1!11ZaDor i ;:> 0 no., job. no .. etc.)

  • Foat of Fl!.rt+/-Dnwrxrl Raad, HaDCX>Cks Brj dge, ID 08038 (address)

(name) Foot of Buttonwood. :Road, Hancocks Bridge, NJ 08038 (address)

3. !lilame, adcress and identification of nuclea" power plant Salem Nuclear Generatir}; =tatiai Unit #2 Foat of art:tonwocrl Road, Hanqx:ks Bridge~ NJ 08038 4 System steam Generator Blawdown Nlx::lear Class II 5 a: Componer.t repaired, modified or replacec ~2"""2,..Gr.a..B4=-------'V ......v"'e..._____________________________
                                                                                        ....hl b: Namemmarnufacrurer_----JMa~~saneo...u..c..ii~J~a~nU----------------------------------
           -    Identifying        res. N00130-2-2                       N/A                                                          NIA                           NIA                            1987 (mlr's. serial no.)          (Narl.Bd.No.)                      uurisdictional no.)              '                              j (year built) c! Constructicr Code                 ASME Sec. TIT 1971                         S?l                                                            NG ANSI 831. 7 1969 :MfitiorJ.970 Add.                                  (addenda)
                                                                                                                                                             '                                     (Code Class)
6. Section XI 1993 _ ___.si........mnre
                                                                                                                 ......--...r.........,a._3__________                                                        1'/A (edition)                                                               (addenda)                                                             . Gode Case(s))

7 Applicable ediaon of ASME Code Section XI u;der which repairs, modifications, or replacements were "'1at2: 1983 S83 "'"'N,_,,/A'""---- (ed;:ai) *~nda) (Code Case(s)) S. Applicable ediaon of Construction Code under which repairs, modifications, or replacements were maoe *l.971 S71 N/A

                                                        .          *ASME III/ANSI B31. 7 1969 F.d. 1970 MC-                                                          i!!:iillOn;            aooenda)           (Code Case(s))

9 :lesign resporsibilities ___,,1;:.,;z,j~..z_-------------------------------------- rn "."ests conduc::E!::!: hydrostatic D pnewr.a11c D design pressure D **pressure NOP ps Code Case(s --N~/"""A._______ 11 :iescription ot .w:irk Rep1 aa=d pl u; and stem ac;sembly arrl valve l:x:>Dne:"".... (use of additional sheet(s) or sketch( es) is acceptae11e ~ ra::e-"y ide'":'ed) CERTIACATE OF COMPLIANCE We ::ertify that the statements made in this repor. are correct and the repair, modification or replacement of trlE ter.s des::ibed ate...: conforms to Section XI of tr.e ASME Code and the Natiol)al Board rules a5 defined in the publication NB-102, current edition. Cer.if!C<lte of Autho-tzation no. 36 to use the "NA" stamp expires Oct. 3, . 19 :4 Date L-2-o ~ ~ ~ PSE&G Co.-Nuclear Dept. 19.~ Signed _ _ _ _ _ _ _ _ _ _ _ _ _ __ Principal Ergr (repair organization) (title) CERTIFICATE OF INSPECTION

  . i. tt:e undersignec. "1olding a valid commission iss..Jed by The National Board of Boiler and Pressure Vesse! "inSlE!COrs. a~d certif1:a:e of competency issued by 1he s:ate or province of                     New       Jersey        and employed by                                 Arkwright Mutual :!:::sJran:e Co c:A          MA                  have inspected the repair. mcdification or replacement described in this report on                                        F _,  ~             . 19(/ ;,._. and state that to the best ::>f my knowlea;le and belief, this repair, modiiiication or replacement has been made in accordance wilt' St!::::a.1 XI o' the ASIJE Code and the National Boar: rules as defined in the publication NB-102 . .::urrent edition. By signing this certificate, neither the lns:>e::or -or his employe* -:-.akes any warranty,
  • expressed or implied, concerning the repair, modiiiication or replacement described in this report. Furtherrr.o11: ielt"ler the lnspec:cr nor his employer shall be
    '     le in any manner for any personal injury or pr"'wperty damage or a loss of any kind arising from or connec:iec: -~ti- this ir.spection
                                                                /1
          -__,£-u...-'...;...3L-/_   . 1{[L___       Signed   l  t/ t AALV Z/
  • lt~ /

(Inspector) . Commissions "- Factory Mutual System

                                                                                                                                                                  ~] 73 (Nat!.Bc:..No.1"TI:wding wdorseme"tS;s-.ate Cl' province and number)

I This form ma.of be obtained from The Natioma_I Board of Boller and Pressure Vessel Inspectors, 10!i%ClUpper Avenue. Columbus, OH 43229. NB-81

                                                                                                                                                                                                                              ~ev 6

FORM NR-1 REPORT OF REPAIR D MODIFICATION 0 OR INSTALLATION OF REPLACEMENT;~ 6 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS

  • of 1 woo. ::r.ri:r-ie= by Bihl i c Senri n:! El ect:ri c & r..a.s en - Nuclear Dept. CJP #592-362
                                                                                                                                  ."lame)                                                              -.;ipair organization's P.O.        "Cl .* p:   "a. . .f!tc.)
  • IocX: of 1}rt:tawxrl Rood, Hcmcxx:ks Brici;J;. NJ 08038 address)
name)

Foot of a.rttaJwood Road, Hancocks BriQ;e. NJ 08038

address)
3. Name. :ca=ss and identification of nuclear power plant _ ___.Sal .........e:n,...._Nu~.,.c...l.,.e..,e.,.r.__,Genera..,.......,...,...,,t...ID1o.u>;~S...,ta......_t,.,1
                                                                                                                                                                                                                    ...*o,.....nL_~Uni~*~t.,__j~l______
                    ?cot of art:torwxrl Brad, Harxxcks Bri cq:, NT 08038
4. Sys1err Olemic:al Vol nme Control Nuclear C1 ==ss II
5. a: Cor.-t:ore"":: --epaired, mocfrfied or replaced _l...CV5....,......,.5..___,V.....a._.l...,v..,e-...._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

b: Nam= er ~.a"lufacturer _ __.M ...~....,,sa

                                                                ......ne
                                                                       ......i...l...a..in.,.__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

c: lderofyln; "'OS. 741 0-95269-.... 1 _ __....,N~/~A-- I NJA 197<= (mlr's. ser.al no.) (Narl.Bd.No.) O.rscic:11onal no.) (olhe" ~'=! nuil!) d: Coru:r..c::icr Code ASME Dp&V 1 968 1 970 N/A

                  ~5I       B31. 7      1969 (Bili~n)l970                           Add.              (addenda)                                                              (Code Cases))
6. Sectior .(: 19a3 ---S~n;mne........,..,.,..._*...,8,_3.___ _ _ _ _ _ __

(edi:.on) .addenda) (Coce Ciiie< s; i

7. Appftca:ie :dr;*:m of ASME Code Section XI under which repairs. modif1:ancns, or replacements were made 1983 (edition)

S83 (adde-ca; N/A. Code Case(s;

8. Applica:ie a:::ir.Jon of Construction Code under which repairs, modificatio-s. er replacements were made: *19'68 1970 1'/A
                                                                            *ANSI B31. 7 /ASME Draft Code for Punps tpdition)                                                                                                      (addl!f'ea"           Code Case(s)~
9. Desigr =soy-sbilities ESE&G Valves 1968 F.d. 1970 Adc:L/W Spec. 3-f,A.58DF'P
10. Tests c::ro...L.""TEC: hydrostatic D pneumatic O design pressu~ : *~essure oop psi Code Case(s) _ __.t\...,,_.n...______

DescriPicr ~ .-:>rk Replaced plug and stem asseOOliy and rewelded leak-off OOre whidi RS (use of additiona :1.-eei.s) or sketc:-{es) is ao::eptable if p":llerly identified) c..t to facil j tate ma j ntenance.

12. Reman;; #: $MD 92-"jl E CERTIFICATE OF COMPLIANCE We certify t-a: ::->: s:-.atements made in this report are correct and the repair '"'!ociification or replacement of the tEms described above C0'1f::r-s :::: Section XI of the ASM: c.:.:ie and the National Board rules as defined in the publicatior ~8-102, current ecition.

Certi~icate ':f A....tr'!or:Zation no. 36 to use the "NR' stamp ex:ires Oct. 3 ,. 19 S4 . Date Y-;:;.? 19. 9 2-. Signed_ _ _ PS_E_&G __eo_.-_Nuc __l_ear __Cept _ _* _ >~- (repair organization) :authorized "feresentative) CERTIFICATE OF INSPECTION _I, the undersi;re:: '"'Olding a valid commission issued by The National Beare Jf :Oiler and Pressure Vessel lnsi:ectors, and certificate of :::om:E!em:y issued b) the sta:e *or ::r.:-.*r-i::e of New Jersey and employed by Arkwri t Mutual L""lSUral'lCe Co of ~ have inspected the repair, modification or replacement o:sc-i:led in this report on and sa:e tnat to the best of my +.-cw*e~e and belief. this repair, modification or replacement ha~~ made in aCCOfdance with Se:::ion XI of the ASME Cooe a"C ne National

 . Board r.Jles as :efinad in the publication NB-102, current edition. By signing ti1s ::ertificate. neither the lnspecto- nor his employer makes                                                                                                an~  .warranty, expressed o- (-oiied. concerning the repair, modification or replacement des=ibed in this report FtJrthermore. reither the Inspector nor his er-CXDyer shall be le in  atl) ...,an.,er for any personal injury or property damage or a loss of <r.y kiind arising from                                                   Of     connected wth this inspection.

r /. ,, Factory Mutual Syst::em,1

          .........,___,'-#-_ . 1&1__. S i g n e d i ; / t' * ~                                                                                          Commissions._.-../.~./--f"..c.,l~?.......:L                        __________

(Inspector) * (Na~.Bd.No.(r-duding endorsements)stare or ?"="*r:::e and nurri:>e*' This fam may be obtained from The National Board of Boiler and Pressure Vessel Inspectors, 1055 Crupper Avenue, Columbus. OH 43229.

FORM NR-1 REPORT OF REPAIR 13 MODIFICATION 0 OR INSTALLATION OF REPLACEMENT($) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS P.O.# Pl-419491

1. work performed by Welding Services, Inc. W.0.# 920627062 Act. 01

( - ~** P. 0. no....... no..lllC.I 2225 Skyland Court, Atlanta, Georgia 2.0wner~_P_u_b_l_i_c_S_e_rv_i_c_e_E_l_e_c_t_r~i~*c_a_n_d_G_a~s_._C_o_._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ Foot of Buttonwood Road, Hancocks Bridge, New Jersey 08038

                                                                                                  <-I
3. Name.addressandidentificationofnuctear?owerplant Salem Nuclear Generating Station Unit Ill Foot of Buttonwood Road, Hancocks Bridge, New Jersey 08038
4. System Steam Generator Feed Pump Discharge 5 a: Componentrepaired.modifiedorreplaced Steam Generator Feedwater Nozzle and Piping b: Name of manufacturer Steam Generator - Westinghouse; Piping - Pullman-Kellog c: Identifying nos. See Attachment 1 (mlr.'1 MrW no.J (Nal'I. Bel. No.J Ouri9dic:IJonal no.J d: Construction Code See Attachment l'---------

(ed1tionJ (lllldendal {Cod9 Cue(a))

6. Section XI 1983 Summer 83 N/A (edlllonJ ~ ic-c-(t))

7 Applicable edition of ASME Code Section XI under which repairs, modifications. or replacements were made: 1983 S/83 N-416 (edlllonl (8dd9ndaj ~ Cmecl!J

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: ~ Attachment l (Codej ledltianl
9. Design responsibilities _ _.,,_P"""""',.,.&'-"'--------------------------------------
10. Tests conducted: hydrostatic O pneumatic a design pressure a pressure psi System Inservice Test @ NOP /NOT
11. Description of work Steam Generator ...,; repair feedwater nozzle; Piping - replaced feedwater piping (UM ol addttiona/ en-(1J Of - l l (
  • J io ~ ~ propelly identlfiedj All work performed in accordance with Welding Services, Inc. Traveler No. 920627062 CERTIACATE OF COMPUANCE We cenity that the statements made in this repon are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition.

Certificate of Authorization no. 69 to use the "NR" stamp expires November 7 , 19E,_. Date t/&.d ;i 8 19, q 2... Signed __w_e_l_d_i_n_g_Se_rv_i_c_e_s_,_I_n_c_._ _ -;...~-......~;:;..:;.---~....d?'l-~'-----.S- ....~e_O_A__ ,~go,. . tn__.'"".......... 1 INPM ~I (AUiilQ(tZ-1 ~l (Ullel CERTlFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of BOiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwri ht Mutual Insurance Co~ of MA have inspected the repair, modification or replacement describe in this report on .J.. , 19 2... and state that to the best Of my knowledge and belief, this repair, modification or replacement has been made in accordance With SeCtion XJ of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty. upressed or implied, concerning the repair. modification or replacement described in this repon. Furthermore, n~ither the Inspector nor his employer shall be liable in any manner for any personal injury or ope amage or a less of any kind arising fro~or connectad with this iA$~ion. raccory -~ucuaJ. ;:,yst:em Date 9r/ I , 19?Z. Signed (AulhOnZed lnsP9C!Of! Commissions £t'd 6 :Jy ' f ~..// ~ /j (Nall.Sd.No.(lnduding *~)Ila!*

                                                                                                                                                                                               /.C A.).:;r Cf :/

or pioy;nc. l.nd numt>erJ I

  • fonn may be obtained from The National Board of Bot'ler and f'reissunt Vessel Inspectors, 1055 Crupper Avenue. Columbus. OH 43229. N&31 R.11.s

Welding Services Inc .

  • 2225 SKYLAND COURT NORCROSS, GEORGIA 30071 TELEPHONE (404) 452-0005 Ff>.:X (404) 729-8242 ATTACHMENT I toNR-1 P.O. #Pl-419491 W.O. # 920627062 Act 01 STEAM GENERA TOR PIPING
5. c: Identifying Nos.:

Manufacturer's Serial No. 1003 None National Board No. 68-10 None Jurisdictional No. None None Other N/A N/A Year Built 1970 1977

5. d: Construction Code:

Edition ASME Sec. Ill 1965 831.1, 1967 831.7, 1969 Addenda W/65 None Code Cases N/A N/A Code Class A II ( 1)

8. Applicable edition of Construction Code under MATERIAL Fabrication which repairs, modifications Weld Filler &

or replacements were made: Fittings Material Examination CODE ASME Sec. Ill (2) ASMEScc. m ASMEScc.ill 831.7 EblTION 1965 (2) 1983 1986 1969 ADDENDA W/65 (2) S/83 None None CODE CASES N/A None None None ( 1) All replacement activities performed in accordance with Class I.

12) Filler material furnished in accordance with ASME Section Ill 1986 Edition, No Addenda; Welding Procedure Specification qualified in accordance with ASME Section IX.

1989 Edition with 90 Addenda .

Mll-Q-050 Rev. 1

        ,                                                                          fa;e C
                                                     !NCLOSURI I VISUAL INSERVICB INSPBCTION DATA SB.KIT W SI. TtA V&: L£il. .J:. P.

Ce~e Jee t fc.v 9.~i,.,t

          ..... . Work Order I
3. System Re A croR:. coot.. AtJT (-:#: I I snri. GelJ. tJo zz L.~)
4. Nuclear Class I
s. P.S. PipinQ or I..sornetric Orawin9 I 2c$ 202 SU.'- 3
6. Syste~ at ~est psig Pressure Cf'"
i. Systerr at ~est Terrperature 42.7 OF
          £.      Req~ire~       Hold Tirre at Test Pressure                 4 Jl,;.s.        Minutes
s. Test Bo~ndary Description ANp LA.~T WE:c,..D ON
  • lC.

11. Actual 7i.i:.e at Test Presusre Exceeds Ret;i..;ire: Hold Time: Yes X No

                  !nspectio~ Results/Remarks:~~~N---"-o~~L~~~A~~~-~~~-O~B:;;.....;;;_S~E~R~v~E~~'--~~
12. Work Request/Work Order Initiated: No X Yes WR/WC t N/A
13. Nuclear Shift Supervisor Notified: No X Yes
14. Inspectior. Cc:r.pleted: Satisfactory -15.._ Cr.satisfactory* _ _

or evidence of structural distress. 8*1.'1*'12

                                                                     ~T LEVEL                 DATE
                                                                 ¥71{-v
                                                              ~<t/l./".:LT                  <?/;J..(,/'I z._-

I ... *** VT LEVEL. DA TE K31.1

FORM NR-1 REPORT OF REPAIR 13 MODIFICATION 0 OR INSTAUATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS ANO SYSTEMS IN NUCLEAR POWER P~NTS P.O.# Pl-419491 wortc performed by 'Welding Services, Inc. W.0.11 920627064 Act. 01

                                                                                                    ,,..,,.,                                                 ( . _ ororv-i'!IW'llmlilon1* P.O. no. jaO. no.,.u:.1 2225 Skyland Court,                         Atlanta, Georgia                        30071 2.0wner ___P_u_b_l_i_c_S_e_rv_i_c_e_E_l_e_c_t_r_i_c_a_n_d_G_a_s_C_o_._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __

Foot of Buttonwood Road, Hancocks Bridge, New Jersey 08038 (9dc1Nm)

3. Name. address and identification of nuclear power plant Salem Nuclear Generating Station Unit #1 Foot of Buttonwood Road, Hancocks Bridge, New Jersey 08038
4. System Steam Generator Feed Pump Discharge
s. a: Component repaired. modified or replaced Steam Generator Feedwater Nozzle and Piping b:Name of manufacturer Steam Generator - Westinghouse; Piping - Pullman-Kellog c: Identifying nos. See Attachment 1 (mlT."1 _,..no.) (Nm'I. Bel. No.I
  • Quri9dlclional no.) {othel) d: Construction Code See Attachment l ________

(edlllOn) (addenclal 6.. Section XI 1983 Summer 83 N/A (lldlllon) {Mdendaj (Code c:-c.i1

7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S/83 N-416

{edlllon) ,_ _ _ (Ccd9 ~

8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: ~ Attachment 1
                                                                                                                                              !(:ode)      {edition)         (~
9. Design responsibilities __~........_....,.""'-------------------------------------------------

to. Tests conducted: hydrostatic a pneumatic C design pressure a pressure psi System Inservice Test @ NOP /N01

11. Description of work Steam Generator - repair feedwater nozzle; Piping - replaced feedwater pipir (UM cl lldd~ional lhMl{I) 01 -ell{*) i8 ~ W~ idenllll9d)

All work performed in accordance with Welding Services, Inc. Traveler No. 920627064

12. Remartcs: _____________________________________________________

9Eff I IACATE OF COMPLIANCE We certify that the statements made in this report are correct and the repair. modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization-no. 69 . to use the "NR" stamp expires November 7 , 19~. Date fi~..,.!! .'2.e- 19,'il-. Signed 'Welding Services, Inc. .~H'7'L- ..S.t('. qA V"t'lc:n .. ,.,,.,.... c._, Olpftinllonl ~ 8Cl~*--1 (11191 CERTlFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwri ht Mutual Insurance Co. of MA have inspected the repair, modification or replacement describe in this report on lo "- , 19~and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordance 'th Section XI of the ASME Code and the Nation< Board rules as defined in the publication NB-102. current edition. By signing this certificate, neither the Inspector nor his employer mues any warran~ e11pressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or damage or a loss of any kind arising froro.or connected with tills iQ!l~ion. tac~ory Mu~uaL ~ys~em

              ~/Ir   I                                                                   1
                                                                                                                                               ~ Jy. y Date                       ,19?'-:- Signed                                                                        Commissions   AJQ                         M1S B /                   s-<./J'"'/JI (Authonud lnsp9cton                                (Nlll.Bd.No.fincluding endolsMn9"111)11m* or           Pf~ and         numb9f)

Thia form may be obtained from The National Board of Boc1er and Pressure Vessel llispec:IDf'a, 1055 Crupper Avenue. Columbus, OH 43229. NB-8 R.v.I

  • Welding Services Inc .

2225 SKYLAND COURT NORCROSS, GEORGIA 30071 TELEPHONE (4Q.C) 452-0005 FAX (404) 729-8242 ATTACHMENT 1 to NR-1 P.O. #Pl-419491 W.O. # 920627064 Act. 01 STEAM GENERA TOR PIPING

5. c: Identifying Nos.:

Manufacturer's Serial No. 1022 None National Board No. 68-8 None Jurisdictional No. None None Other N/A N/A Year Built 1970 1977

5. d: Construction Code:

Edition ASME Sec. Ill 1965 831.1, 1967 831.7, 1969 Addenda W/65 None I Code Cases N/A N/A Code Class A II ( 1)

8. Applicable edition of Construction Code under MATERIAL Fabrication which repairs, modifications Weld Filler &

or replacements were made: Fittings Material Examination

                      .CODE                      ASME Sec. Ill    (2)  ASMEScc. ill        ASMEScc. ill         831.7 EDITION                            1965    (2)      1983               1986             1969 ADDENDA                           W/65     (2)      S/83                None            None CODE CASES      \                         N/A       None               None             None

( 1) All replacement activities performed in accordance with Class I. (2) Filler material furnished in accordance with ASME Section Ill 1986 Edition, No Addenda; Welding Procedure Specification qualified in accordance with ASME Section IX. 1989 Edition with 90 Addenda .

Mll-O-OSO le*. 1 Page C

  • l .

w SJ: Ceele Je~ TR.IW~ fC:I/ 8. Zb* 'ti I LEll ~.I>. DCLOSUll I VISUAL INSERVICI IMSPICTION DATA SHllT

                                              ~-L.o f, 2 7   O<o Y
                                                                                .J1
                                                                         ,..c-r * :L
    ". Work Order I                 9 Z.O <o Z. 7  0" '-I
3. System
4. Nuclear Class I 1.
s. P.S. Pipino or I~ometric Orawin; I 20S 202. SIL# 3
6. System at Test Pressure 91~ psi; i . System at Test Temperature '-iZ 7 °F
    £. Req~ired         Hold Time at Test Pressure                   4   HR.S.             Mini..~es
9. Test Boundary Des~riptio&

A.vp ~A Si WELl> ON Ree &..Acep F irr jel2.

10. Actual Time at Test Presus~e Exceeds Required Hold Ti~e:

Yes X No

11. Inspection Results/Remarks=~~N_o~__ L__A~K_s~__ O_s_s~e~R-~_E_P_________
12. Work Request/Work Order Initiated: No _X __ *Yes WR/WO I NIA
13. Nuclear Shift Supervisor Notified: No X Yes
14. Inspection Completed: Satisfactory~ Unsatisfactory* _ _
  • Any source of leakage or evidence of structural distress.

fwc.v~k IC s -2t*<tz VISUAL ~ECTOR VT LEVEL DATE QA* l/T(-'I JL~~~/~ ~~~- vT LEVEL . H31.1

FORM NR-1 REPORT OF REPAIR CJ MODIF1CAT10N 0 OR INSTALLATION OF REPLACEMENT(S) 0 I' TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER Pl.ANTS P.O. t} Pl-419491 Work performed by Welding Services, Inc. w.0.11 920627066 Act. 01

                                                                                                ,_                                                                (-~*1P.0.                 rm. job. no.,lllC.l 2225 Skyland Court,                   Atlanta, Georgia                        30071 2.0wner _ _P_u_b_l_i_c_S_e_rv_i_c_e_E_l_e_c_t_r_i_c_a_n_d_G_a_s_C_o_._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _~

i-1 Foot of Buttonwood Road, Hancocks Bridge, New Jersey 08038 1--i

3. Name.addressandidentificationofnuclearpowerplan1 Salem Nuclear Generating Station Unit #1 Foot of Buttonwood Road, Hancocks Bridge, New Jersey 08038
4. System Steam Generator Feed Pump Discharge
s. a:Componentrepaired,modifiedorreplaced Steam Generator Feedwater Nozzle and Piping b:Name of manufacturer Steam Generator - Westinghouse; Piping - Pullman-Kellog c:ldentifying nos. See Attachment 1 (mfr.'s - no.1 (Nml'I. Bd. No.) {jlli9dicllon8J no.) (olllef) (y9W builll d: Construction Code See Attachment l _ _ _ _ _ _ __

(~

6. Section XI Summer 83 N/A (eddlonl ~ (Code c:-1111
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacements were made: 1983 S/83 N-416 (edition) ~ (Ccd9 ea.
8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: See Attachment 1 (Code) (eclMionl (~
9. Design responsibilities _ _=---""-"'""'-------------------------------------
10. Tests conducted: hydrostatic a pneumatic a design pressure a pressure PSi System Inservice Test @ NOP /NO'
11. Description of work Steam Generator - repair feedwater nozzle; Piping - replaced feedwater pipi (UM ol Addrtional lhMl(I) or -.:l'l(n) ii llCC9lllAble H po_.iy iderdied)

All work performed in accordance with Welding Services, Inc. Traveler No. 920627066 CEA IFlCATE OF COMPllANCE We certify that the statements made in this report are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorizatioh no. 69 to use the "NR" swnp expires November 7 , 19~. i2 £ 19, 9 2.. Signed __w_e_l_d_i_n_g_S_e_rv_i_c_e_s_,_I_n_c_.___ _.:Xo:;..;..&&...:~'-"~-""'/.-

                                                                                                                                            ....l*-'----- --'S""'."""~~-=Q~A'-'--_.trL..1i.::*.:i......i. ;~ ,. ,.
                                                                              ,,_,~,                                           (ldhonzec1     ~I                               (11119J CERI FICATE OF INSPECT10N I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of          New Jersey                      and employed by             Arkwri ht M tual Insurance Co.                                             .

of MA have inspected the repair, modification or replacement describe in this report on 2 , 19 ~and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordan with Section XI of the ASME Code and the Natior Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warran expressed or implied, concerning the repair, modification or replacement described in this report. Furthermore, neither the Inspector nor his employE shall be liable in any manner for any personal injury or pr

                                                                                        *,age or a loss of any kind arising froru.or ~nnect&d V(_ith this iA.!l.P.ection.

racc:ory ~uc:ua.I ~ystem

                'l/II             , '?Z                l'1?
  • S' Commissions Vt.I 6 .J ~ 'f .<./1s13 J *=:l A/Er~ ::r 1 Date 19 Signed (Authorized mpectOI) (Nall.Bd.No.(lncluding enoon-u)-* or p<oW>c:e and numbef This form may be obtained from The National Board of Boiler and Pressure Vessel mpectors, 1055 Crupper Avenue, Columbus, OH 43229. NB Re-
                                                     !Iii\       -  ~=~~'!,~"'Services
  • \!!V NORCROSS. GEORGIA 3007' TELEPHONE (4Q.4) 452*0005 FAX (404) 729-8242 Inc.

ATTACHMENT 1 to NB-1 P.O. #Pl-419491 W.O. # 920627066 Act. 01 STEAM GENERATOR . PIPING

5. c: Identifying Nos.:

Manufacturer's Serial No. 1023 None National Board No. 68-9 None Jurisdictional No. None None Other NIA NIA Year Built 1970 1977

5. d: Construction Code:

Edition ASME Sec. Ill 1965 831.1, 1967 B31.7, 1969 Addenda Wl65 None Code Cases NIA NIA Code Class A II ( 1)

8. Applicable edition of Construction Code under MATERIAL Fabrication which repairs, modifications Weld Filler &

or replacements were made: Fittings Material Examination

                      'CODE                      ASME Sec. Ill    (2)   ASMEScc.ill        ASMESec. ill           831.7 EDITION                           1965     ~i)      1983                1986              1969 ADDENDA                           Wl65     (2)      5183                 None             None CODE CASES                                NIA       None                None              None

( 1) All replacement activities performed in accordance with Clas9 I. (2) Filler material furnished in accordance with ASME Section 111.1' 986 Edition, No Addenda; Welding Procedure Specification qualified in accordance witn ASME Section IX. 1989 Edition with 90 Addenda .

                                                                                    ~3l-Q-OSO   lev. 1
    ,                                                                               Pa;~
  • ENC1'0S\1Jtl I VIS'JA.l.. INSERVICI INSPBCTION DATA S!XBT W .SI. Tii!..A*Jf..£~ .:z: .D.

Ce~e Jee I

             " 8*2'9*U
      ~     Work Order I
3. System RE Ac TOR. coot. A~I ( .J13 STN\. G£1J_ t..101.?t.E)
4. Nuclear Class I
5. P.S. Pipin; e~ I~ometric Drawin9 I ~0.5 '2. 0 4 SU.~3
6. Syste~ at 7:s: Pressure 91'.? psig
7. Systeir. at '::s: Terr.perature "i.. 7 oy
      £. Feq~ired      H::~     Time at Test Pressure                y        ~RS.           Y.inutes
9. Test Sounde:y Description AIVi> -*ST WEirp Or.J /?E. PLA C.CI> Fi rr ,*,...-: -
  • 10.

11. Actual Ti~~ Yes X a~ Test Presusre Exceeds Requi:e: Hold No

nspection ~:sults/Re~arks=~~~N~o'--~L~'~A~k_S~_O~B_S~~~&-~~e=---D~~-

Ti~e:

12. ~ork Request Work Order Initiated:

1 No X Yes WR/WO I N/A

13. Nuclear Shi!~ Supervisor Notified: No X Yes
14. Inspection C*~:!!lpleted: Satisfactory~ l"::satisfactory* _ _
  • Any source of evidence of structural distress.

9*2'7* '12. VISUAL ISS?E VT LEVEL DATE

            ~            /!, >-                          .at-'( )C..1LEVEL~

r./ .t / ~v/Pe VT o>.ri M31.1

FORM NR-1 REPORT OF REPAIR [J MODIFICATION 0 OR INSTALLATION OF REPLACEMENT(S) 0 TO NUCLEAR COMPONENTS AND SYSTEMS IN NUCLEAR POWER PLANTS P.o.b Pl-419491

i. Work performed by Welding Services, Inc. w.0.11 920627067 Act. 01
  • 2225 Skyland Court, Atlanta, Georgia (Mmel Foot of Buttonwood Road, Hancocks Bridge, New Jersey 08038
                                                                                                       <--i
3. Name,addressandidentificationofnuclearpowerplant Salem Nuclear Generating Station Unit ill Foot of Buttonwood Road, Hancocks Bridge, New Jersey 08038
4. System Steam Generator Feed Pump Discharge
s. a:Componentrepaired.modifledorreplacecl Steam Generator Feedwater Nozzle and Piping b:Name of manufacturer Steam Generator - Westinghouse; Piping - Pullman-Kellog c:ldentifying nos. See Attachment 1 (mfr.'s MnaJ no.1 (NC'I. Bel. No.I (OChefl d: Construction Code See Attachment 1_ _ _ _ _ _ __

(edllionl (~ !Code C..(911

s. Section XI 1983 Su11DDer 83 N/A (lldillanl ~ (Cod9 c..flll
7. Applicable edition of ASME Code Section XI under which repairs, modifications, or replacemeMs were made: 1983 S/83 N-416 (edlllon) ~ ~ c..CI;
8. Applicable edition of Construction Code under which repairs, modifications, or replacements were made: See Attachment 1 (Code1 (edlian) ,..,.
9. Design responsibilities _ _. . _ . . " " " " " " ' - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
10. Tests conducted: hydrostatic D pneumatic D design preuure C pressure
  • psi System Inservice Test @ NOP /NOT
11. Description of work Steam Generator - repair feedwater nozzle; Piping - replaced feedwater pipir.

(UM ol ..idttional .,_(II °' -cll(nl ii KCeplable I prop9fly idenllfied) All work performed in accordance with Welding Services, Inc. Traveler No. 920627067

12. R e m a r k s = - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

camFICATE OF COMPUANCE We cenify that the statements made in this repon are correct and the repair, modification or replacement of the items described above conforms to Section XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. Certificate of Authorization .no. 69 to use the "NR" stamp expires November 7 , 19~.

      ,. Date   .#.,,.."     J.::5 19, n . Sig5!"1 __w_e_l_d_i_n..;;..g_S_e_rv_i_c_e_s_,_I_n_c_._                    -..J'..::~~~=:i.--=-£-=*.oe,_..;,.,:;;;;;,__~---,-
                                                                                    <*91191, OlplliZallOnl                          ~ *--*-

CERTlFICATE OF INSPECTION I, the undersigned. holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors, and certificate of competency issued by the state or province of New Jersey and employed by Arkwri ht Mu ual Insurance Co. of MA

  • have inspected the repair, modification or replacement describe in this report on , 19 Z.. and state that to the best of my knowledge and belief, this repair, modification or replacement has been made in accordan with
  • n XI of the ASME Code and the National Board rules as defined in the publication NB-102, current edition. By signing this certificate, neither the Inspector nor his employer makes any warranty,
         **pressed or implied, concerning the repair, modification or replacement described in this repon. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or ~amage or a loss of any kind arising fro"Fi'c1?8't~ct~Jt1ll~s \:?~4m*

Date 9/1 / ,199~Signed ~ .S -"'~~ Commissions&/*.'.:?~ .Jt',ey Vl.J(f, J  !(.);rCol-St

                                                                                  !AulhOfiZed ln1pee1Cll)                                (N8U.Bd.Ho.(lndudin;      *~Ill- or        Pfl"'ince and number) 1 This form may be obtained from The National Board of Boiler                       and Pressure Vessel 1nspec1Drs. 1055 Crupper Avenue, Columbus, OH                           ~-         /     NEHi Rew.8
  • Welding Services Inc.

2225 SKYLAND COURT NORCROSS. GEORGIA 30071 TELEPHONE (404) 452*0005 FAX (404) 729*8242 ATTACHMENT 1 to NRml P.O. #Pl-419491 W.O. # 920627067 Act. 01 STEAM GENERATOR PIPING

5. c: Identifying Nos.:

Manufacturer's Serial No. 1203 None National Board No. 68-51 None Jurisdictional No. None None Other N/A N/A Year Built 1971 1977

5. d: Construction Code:

Edition ASME Sec. Ill 1965 831.1, 1967 831.7, 1969 Addenda S/66 None Code Cases N/A N/A Code Class A II ( 1)

8. Applicable edition of Construction Code under MATERIAL Fabrication which repairs, modifications Weld Filler &

or replacements were made: Fittings Material Examination

                      'CODE                      ASME Sec. Ill    (2)   ASMESec. ID       ASMESec. m           831.7 EDITION                            1965    (2)      1983               1986            1969 ADDENDA                            S/66    (2)      S/83                None           None CODE CASES                                N/A       None               None            None (1 l All replacement activities performed in accordance with Class I.

(2) Filler material furnished in accordance with ASME Section Ill 1986 Edition, No Addenda; Welding Procedure Specification qualified in accordance with ASME Section IX. 1989 Edition with 90 Addenda .

              ,    .                                                                           Mll-Q-OSO lev. 1 Pa9e *
  *-                 l.

W 5L Cede fCV Je~ I B*i... Tf{A\1£ LEll ::t.D.

                                          ,2.

DCLOSUJtl I VISUAL INSERVICI INSPBCTION DATA SBllT

                                                                   .** 'f Z.O "Z 1 0  >>7       !{;,T I ;1..
                     ~. Work Order t                  ~20 fJ27 0~7
3. System RE.AC ro~ C.OOLAAJ/ &N S'r"A\. G£tJ. NOZZL!.)
4. Nuclear Class t 1 s.

6. P.S. Piping or System at Test Pressure I~ometric*orawin9

  • 205 20Z.

9/to 5#.4F3 psig

7. Systeir. at Test TeIT1perature '12. 7 or
                     ~. F.eql..;i red Held Time         at   Test Pressure              4 HR.S.            Minutes
9. Test ooundary Description 10.

RE PL.I\ c Et> f irr itJ6 . Actual Tirr.~ at Test Presusre Exceeds Required Hold Time: Yes X No

11. !nspec ti on Results /Remarks: ___N_o__L_e_A_i.::_s_ _O_s_s_~_R.._l/~--r>'"----
12. .

Work Request/Work Order Initiated: No X WR/WO t Yes WA.

13. Nuclear Shift Supervisor Notified: No )<. Yes
14. Inspection Co~pleted: Satisfactory _1S_ Unsatisfactory*~
  • Anl source of leakage or evidence of structural distress.

rPo..J.c. v~ B*Zlo* DATE

                                                                                                                   ,'l.

8/;1,/f-i.,; M31.1

                                                                                                          ~DATE}}