MONTHYEARML0603800992006-02-0909 February 2006 Request for Additional Information Response to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design-Basis Accidents at Pressurized-Water Reactors (TAC MC4689 & MC4690) Project stage: RAI ML0705104762007-02-0909 February 2007 Licensee Slides 2-9-07 Project stage: Other ML0704701232007-02-26026 February 2007 Summary of February 9, 2007, Meeting with Entergy on the Response to Generic Letter 2004-02 for Indian Point Nuclear Generating Unit Nos. 2 and 3 Project stage: Meeting NL-07-098, Request for Extension of Completion Date for Indian Point Unit 3 Corrective Actions and Modifications Required by Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Press2007-10-24024 October 2007 Request for Extension of Completion Date for Indian Point Unit 3 Corrective Actions and Modifications Required by Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressu Project stage: Request ML0732301582007-11-20020 November 2007 Unit No.3 - Denial of Extension Request for Corrective Actions Required by Generic Letter 2004-02 Project stage: Other ML0732301692007-11-20020 November 2007 Approval of Extension Request for Corrective Actions Required by Generic Letter 2004-02 Project stage: Other NL-05-0133, Revised Request for Extension of Completion Date for Indian Point Unit 3 Corrective Actions & Modifications Required by Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents a2007-12-0303 December 2007 Revised Request for Extension of Completion Date for Indian Point Unit 3 Corrective Actions & Modifications Required by Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Project stage: Request ML0735102422007-12-20020 December 2007 Approval of Revised Extension Request for Corrective Actions Required by Generic Letter 2004-02 Project stage: Other NL-08-054, Request for Extension of Completion Dates for Indian Point, Units 2 & 3, Corrective Actions Required by Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Wat2008-03-28028 March 2008 Request for Extension of Completion Dates for Indian Point, Units 2 & 3, Corrective Actions Required by Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Wate Project stage: Request NL-08-119, Proprietary Review of Audit Report for the Corrective Actions Associated with Generic Letter 2004-022008-07-21021 July 2008 Proprietary Review of Audit Report for the Corrective Actions Associated with Generic Letter 2004-02 Project stage: Other NL-08-153, Request for Extension of Completion Dates for Indian Point Units 2 and 3 Corrective Actions Required by Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Wat2008-10-17017 October 2008 Request for Extension of Completion Dates for Indian Point Units 2 and 3 Corrective Actions Required by Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Wate Project stage: Request NL-08-171, Planned Replacement of Internal Recirculation Pump Bearings in Response to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors2008-12-0101 December 2008 Planned Replacement of Internal Recirculation Pump Bearings in Response to Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors Project stage: Other NL-09-021, Response to Request for Additional Information Regarding Generic Letter 2004-022009-02-0202 February 2009 Response to Request for Additional Information Regarding Generic Letter 2004-02 Project stage: Response to RAI ML0926400612009-09-24024 September 2009 Summary of Conference Call with Entergy on Proposed Response to a Request for Additional Information on Generic Letter 2004-02 Project stage: RAI 2007-02-09
[Table View] |
|
---|
Category:Letter
MONTHYEARML24011A1982024-01-12012 January 2024 ISFSI, Notice of Organization Change for Site Vice President ML23342A1082024-01-0909 January 2024 Independent Spent Fuel Storage Installation Security Inspection Plan ML23353A1742023-12-19019 December 2023 ISFSI, Emergency Plan, Revision 23-04 L-23-019, Proof of Financial Protection 10 CFR 140.152023-12-18018 December 2023 Proof of Financial Protection 10 CFR 140.15 ML23339A0442023-12-0505 December 2023 Issuance of Amendment No. 68, 301 and 277 Regarding Changes to Implement the Independent Spent Fuel Storage Installation Physical Security Plan ML23326A1322023-12-0505 December 2023 Issuance of Amendment No. 67, 300 & 276 to Implement the Independent Spent Fuel Storage Installation Only Emergency Plan ML23338A2262023-12-0404 December 2023 Signed Amendment No. 27 to Indemnity Agreement No. B-19 ML23356A0212023-12-0101 December 2023 American Nuclear Insurers, Secondary Financial Protection (SFP) Program ML23242A2772023-11-30030 November 2023 NRC Letter Issuance - IP LAR for Units 2 and 3 Renewed Facility Licenses and PDTS to Reflect Permanent Removal of Spent Fuel from SFPs ML23338A0482023-11-30030 November 2023 ISFSI, Report of Changes to Physical Security, Training and Qualification, Safeguards Contingency Plan, and ISFSI Security Program, Revision 28 ML22339A1572023-11-27027 November 2023 Letter - Indian Point - Ea/Fonsi Request for Exemptions from Certain Emergency Planning Requirements for 10 CFR 50.47 and 10 CFR Part 50, Appendix E IR 05000003/20230032023-11-21021 November 2023 NRC Inspection Report Nos. 05000003/2023003, 05000247/2023003, 05000286/2023003, and 07200051/2023003 ML23100A1172023-11-17017 November 2023 NRC Response - Indian Point Energy Center Generating Units 1, 2, and 3 Letter with Enclosures Regarding Changes to Remove the Cyber Security Plan License Condition ML23050A0032023-11-17017 November 2023 Letter - Issuance Indian Point Unit 2 License Amendment Request to Modify Tech Specs for Staffing Requirements Following Spent Fuel Transfer to Dry Storage ML23100A1252023-11-17017 November 2023 Letter and Enclosure 1 - Issuance Indian Point Energy Center Units 1, 2, and 3 Exemption for Offsite Primary and Secondary Liability Insurance Indemnity Agreement ML23100A1432023-11-16016 November 2023 Letter - Issuance Indian Point Energy Center Generating Units 1, 2, and 3 Exemption Concerning Onsite Property Damage Insurance (Docket Nos. 50-003, 50-247, 50-286) ML23064A0002023-11-13013 November 2023 NRC Issuance for Approval-Indian Point EC Units 1, 2 and 3 Emergency Plan and Emergency Action Level Scheme Amendments L-23-012, Master Decommissioning Trust Agreement Changes for Indian Point Nuclear Generating Units 1, 2 and 3, Pilgrim Nuclear Power Station, Palisades Nuclear Plant and the Non-Qualified Trust for Big Rock Point2023-11-13013 November 2023 Master Decommissioning Trust Agreement Changes for Indian Point Nuclear Generating Units 1, 2 and 3, Pilgrim Nuclear Power Station, Palisades Nuclear Plant and the Non-Qualified Trust for Big Rock Point ML23306A0992023-11-0202 November 2023 and Indian Point Energy Center, Notification of Changes in Schedule in Accordance with 10 CFR 50.82(a)(7) ML23063A1432023-11-0101 November 2023 Letter - Issuance Holtec Request for Indian Point Energy Center Generating Units 1, 2, and 3 Exemptions from Certain Emergency Planning Requirements of 10 CFR 50.47 and Part 50 ML23292A0262023-10-19019 October 2023 LTR-23-0211-RI Thomas Congdon, Executive Deputy, Department of Public Service, Chair, Indian Point Decommissioning Oversight Board, Letter Independent Spent Fuel Storage Installation Inspection and Office of the Inspector General Report-RI ML23289A1582023-10-16016 October 2023 Decommissioning International - Registration of Spent Fuel Casks and Notification of Permanent Removal of All Indian Point Unit 3 Spent Fuel Assemblies from the Spent Fuel Pit ML23270A0082023-09-27027 September 2023 Registration of Spent Fuel Casks ML23237A5712023-09-22022 September 2023 09-22-2023 Letter to Dwaine Perry, Chief, Ramapo Munsee Nation, from Chair Hanson, Responds to Letter Regarding Opposition of the Release and Dumping of Radioactive Waste from Indian Point Nuclear Power Plant Into the Hudson River ML23242A2182023-09-12012 September 2023 IPEC NRC Response to the Town of New Windsor, Ny Board Certified Motion Letter Regarding Treated Water Release from IP Site (Dockets 50-003, 50-247, 50-286) ML23250A0812023-09-0707 September 2023 Registration of Spent Fuel Casks ML23255A0142023-08-31031 August 2023 LTR-23-0211 Thomas Congdon, Executive Deputy, Department of Public Service, Chair, Indian Point Decommissioning Oversight Board, Letter Independent Spent Fuel Storage Installation Inspection and Office of the Inspector General Report IR 05000003/20230022023-08-22022 August 2023 NRC Inspection Report 05000003/2023002, 05000247/2023002, 05000286/2023002, and 07200051/2023002 ML23227A1852023-08-15015 August 2023 Request for a Revised Approval Date Regarding the Indian Point Energy Center Permanently Defueled Emergency Plan and Emergency Action Level Scheme ML23222A1442023-08-10010 August 2023 Registration of Spent Fuel Casks ML23208A1642023-07-26026 July 2023 Village of Croton-on-Hudson New York Letter Dated 7-26-23 Re Holtec Wastewater ML23200A0422023-07-19019 July 2023 Registration of Spent Fuel Casks ML23235A0602023-07-17017 July 2023 LTR-23-0194 Dwaine Perry, Chief, Ramapo Munsee Nation, Ltr Opposition of the Release and Dumping of Radioactive Waste from Indian Point Nuclear Power Plant Into the Hudson River ML23194A0442023-07-11011 July 2023 Clarification for Indian Point Energy Center License Amendment Request, Independent Spent Fuel Storage Installation Physical Security Plan ML23192A1002023-07-11011 July 2023 Response to Request for Additional Information Regarding License Amendment Request to Revise the Emergency Plan and Emergency Action Level Scheme ML23171B0432023-06-23023 June 2023 Letter - Indian Point Energy Center - Request for Additional Information for Independent Spent Fuel Storage Installation Facility-Only Emergency Plan License Amendment ML23118A0972023-06-0606 June 2023 06-06-23 Letter to the Honorable Michael V. Lawler, Et Al., from Chair Hanson Regarding Holtec'S Announcement to Expedite Plans to Release Over 500,000 Gallons of Radioactive Wastewater from Indian Point Energy Center Into the Hudson River ML23144A3512023-05-25025 May 2023 Clementina Bartolotta of Pearl River, New York Email Against Treated Water Release from Indian Point Site ML23144A3522023-05-25025 May 2023 Loredana Bidmead of New York E-Mail Against Treated Water Release from Indian Point Site ML23144A3412023-05-25025 May 2023 Dianne Schirripa of Rockland County, New York Email Against Treated Water Release from Indian Point Site ML23144A3472023-05-25025 May 2023 David Mart of Blauvelt, New York Email Against Treated Water Release from Indian Point Site ML23144A3402023-05-25025 May 2023 Melvin Israel of New York Email Against Treated Water Release from Indian Point Site ML23144A3542023-05-25025 May 2023 Terri Thal of New City, New York Email Against Treated Water Release from Indian Point Site ML23144A3532023-05-25025 May 2023 John Shaw of New York Email Against Treated Water Release from Indian Point Site 2024-01-09
[Table view] |
Text
November 20, 2007
Mr. Michael A. Balduzzi Sr. Vice President & COO Regional Operations, NE Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601
SUBJECT:
INDIAN POINT NUCLEAR GENERATING UNIT NO. 3 - DENIAL OF EXTENSION REQUEST FOR CORRECTIVE ACTIONS REQUIRED BY GENERIC LETTER 2004-02 (TAC NO. MC4690)
Dear Mr. Balduzzi:
In a letter dated October 24, 2007, [Agencywide Document Access and Management System (ADAMS) accession number ML073040291] Entergy Nuclear Operations, Inc. (Entergy) requested an extension to the December 31, 2007, completion deadline for the corrective actions required by Generic Letter (GL) 2004-02, "Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized Water Reactors" for the Indian Point Nuclear Generating Unit No. 3 (IP3). The proposed extension would allow Entergy approximately 14 additional months to complete the modifications and licensing activities necessary to achieve full compliance with GL 2004-02, with completion of this effort to coincide with the completion of the IP3 spring 2009 refueling outage.
The Nuclear Regulatory Commission (NRC) staff has evaluated the information provided in Entergy's letter and has determined that the arguments presented in the letter are not adequate to grant a 14-month extension. The NRC views the scope of the additional modifications required to demonstrate compliance with GL 2004-02 as achievable before the next refueling outage and, therefore, the extension request is denied.
In its letter, Entergy stated that the installation of significantly larger sump strainers and other modifications designed to reduce debris transport to the sumps has been completed. However, the planned modification to change the buffering agent from sodium hydroxide to sodium tetraborate has not been implemented. Further, the letter stated that the planned operating-license amendments to reflect a change to the low-low level set-point of the refueling water storage tank, the change of buffering agent, and the implementation of the exemption from the single failure criterion for large-break loss-of-coolant accidents (LBLOCAs) have not been initiated. Entergy proposed to complete these activities by the close of the IP3 spring 2009 refueling outage, scheduled to begin on March 10, 2009.
The NRC's criteria for granting extensions are contained in SECY-06-0078. The SECY requires that the licensee have a plant-specific technical/experimental plan with milestones and schedules to address outstanding technical issues, and have in place mitigative measures that minimize the risk of degraded emergency core cooling system (ECCS) and containment spray system (CSS) functions during the extension period. The SECY also recommends that for proposed extensions beyond several months, the mitigative measures include temporary physical improvements to the ECCS sump or materials inside containment to better ensure a high level of ECCS sump performance.
After reviewing Entergy's submittal, the NRC staff concludes that Entergy has a plan to complete the remaining corrective actions and has compensatory measures in place. However, NRC finds that Entergy has not made a convincing case why the proposed modifications and other changes cannot be accomplished before the next refueling outage. Further, the importance of completing the corrective actions required to prevent sump strainer clogging was expressed in the "Director's Decision Under 10 CFR 2.206" (ML041700619), which specifically addressed the
petition regarding the operability of the Indian Point Nuclear Gener ating Unit Nos. 2 and 3 sumps. For these reasons, a 14-month extension beyond December 31, 2007, is not acceptable. Therefore, as previously stated, the NRC denies Entergy's request, dated October 24, 2007, for an extension of the GL 2004-02 corrective actions completion date of December 31, 2007. Entergy may submit another extension request for NRC consideration, proposing a shorter extension consistent with the time needed to prepare for and implement remaining corrective actions in an expeditious manner.
Please contact the Indian Point Project Manager, John Boska, at (301) 415-2901 if you have any questions on this issue.
Sincerely, /RA/ Mark G. Kowal, Chief Plant Licensing Branch I-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
Docket No. 50-286
cc: See next page
ML OFFICE LPL1-1/PM LPL1-1/LA SSIB/BC LPL1-1/BC NAME JBoska SLittle MScott MKowal DATE 11/20/07 11/19/07 11/19/07 11/20/07 Indian Point Nuclear Generating Unit No. 3
cc:
Mr. Michael R. Kansler President & CEO / CNO Entergy Nuclear Operations, Inc.
1340 Echelon Parkway Jackson, MS 39213
Mr. John T. Herron Sr. Vice President Entergy Nuclear Operations, Inc.
1340 Echelon Parkway Jackson, MS 39213
Sr. Vice President Engineering & Technical Services Entergy Nuclear Operations, Inc.
1340 Echelon Parkway Jackson, MS 39213
Mr. Fred R. Dacimo Site Vice President Entergy Nuclear Operations, Inc.
Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249
Mr. Anthony Vitale - Acting General Manager, Plant Operations Entergy Nuclear Operations, Inc.
Indian Point Energy Center 450 Broadway P.O. Box 249 Buchanan, NY 10511-0249
Mr. Oscar Limpias Vice President Engineering Entergy Nuclear Operations, Inc.
1340 Echelon Parkway Jackson, MS 39213
Mr. Joseph P. DeRoy Vice President, Operations Support Entergy Nuclear Operations, Inc.
1340 Echelon Parkway Jackson, MS 39213
Mr. John A. Ventosa GM, Engineering Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601
Mr. John F. McCann Director, Nuclear Safety & Licensing Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601
Ms. Charlene D. Faison Manager, Licensing Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601
Mr. Ernest J. Harkness Director, Oversight Entergy Nuclear Operations, Inc.
1340 Echelon Parkway Jackson, MS 39213
Mr. Patric W. Conroy Director, Nuclear Safety Assurance Entergy Nuclear Operations, Inc.
Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249
Mr. Robert Walpole Manager, Licensing Entergy Nuclear Operations, Inc.
Indian Point Energy Center 450 Broadway, GSB P. O. Box 249 Buchanan, NY 10511-0249
Mr. William C. Dennis Assistant General Counsel Entergy Nuclear Operations, Inc.
440 Hamilton Avenue White Plains, NY 10601 Indian Point Nuclear Generating Unit No. 3
cc:
Mr. Paul Tonko President and CEO New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399
Mr. John P. Spath New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399
Mr. Paul Eddy New York State Department of Public Service 3 Empire State Plaza Albany, NY 12223-1350
Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406
Senior Resident Inspector
=s Office Indian Point 2 U. S. Nuclear Regulatory Commission P.O. Box 59 Buchanan, NY 10511
Senior Resident Inspector
=s Office Indian Point 3 U. S. Nuclear Regulatory Commission P.O. Box 59 Buchanan, NY 10511
Mr. Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271
Mr. Raymond L. Albanese Four County Coordinator 200 Bradhurst Avenue Unit 4 Westchester County Hawthorne, NY 10532
Mayor, Village of Buchanan 236 Tate Avenue Buchanan, NY 10511
Mr. William DiProfio PWR SRC Consultant
48 Bear Hill Road Newton, NH 03858
Mr. Garry Randolph PWR SRC Consultant 1750 Ben Franklin Drive, 7E Sarasota, FL 34236
Mr. William T. Russell PWR SRC Consultant 400 Plantation Lane Stevensville, MD 21666-3232
Mr. Jim Riccio Greenpeace 702 H Street, NW Suite 300 Washington, DC 20001
Mr. Phillip Musegaas Riverkeeper, Inc.
828 South Broadway Tarrytown, NY 10591
Mr. Mark Jacobs IPSEC 46 Highland Drive Garrison, NY 10524
Ms. Susan Shapiro via email
Mr. Sherwood Martinelli
FUSE USA via email