MONTHYEARML23339A1332024-01-26026 January 2024 Exemption from the Req of 10 CFR Part 50.82(a)(8)(i)(A) to Use the Kewaunee Decommissioning Trust Fund for the Management of Site Restoration Activities IR 05000305/20230022023-12-27027 December 2023 NRC Inspection Report 05000305/2023002 (Drss); 07200064/2023001 (Drss) ML23332A1922023-11-28028 November 2023 Solutions, Inc., Request for Exemptions from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation ML23278A1002023-10-0505 October 2023 Response to Request for Additional Information (RAI) Application for Kewaunee Solutions (Ks) Site Restoration Activities ML23222A1522023-08-29029 August 2023 Letter RAI KPS Exemption Site Restoration Final Repaired IR 05000305/20230012023-08-17017 August 2023 NRC Inspection Report No. 05000305/2023001-Kewaunee Power Station ML23171B0822023-07-0505 July 2023 Letter - Kewaunee Power Station - Issuance of Exemption from Certain Requirements from 10 CFR Part 20, Appendix G, Section Iii.E ML23132A0012023-05-11011 May 2023 2022 Annual Radiological Environmental Operating Report ML23116A2182023-04-26026 April 2023 2022 Annual Radioactive Effluent Release Report ML23089A3042023-03-30030 March 2023 Decommissioning Fund Status Report ML23088A2752023-03-29029 March 2023 Solutions, Inc., Request for Exemption from 10 CFR 20, Appendix G, Section Iii.E ML23093A0312023-03-29029 March 2023 Solutions, Inc., Request for Exemptions from 10 CFR 50.82(a)(8)(i)(A) and 50.75(h)(1)(iv) for Site Restoration Activities ML23087A0402023-03-27027 March 2023 Annual Property Insurance Status Report ML23087A0292023-03-27027 March 2023 2022 Annual Report of Occupational Radiation Exposure ML22361A1022023-02-24024 February 2023 Reactor Decommissioning Branch Project Management Changes for Some Decommissioning Facilities and Establishment of Backup Project Manager for All Decommissioning Facilities ML23024A0122023-01-26026 January 2023 Letter to Energysolutions Transmitting Threshold Determination for Merger/Restructuring IR 05000305/20220022023-01-0303 January 2023 NRC Inspection Report Nos. 05000305/2022002(DRSS) Kewaunee Power Station ML22292A2302022-11-25025 November 2022 U.S. Nuclear Regulatory Commissions Analysis of Dominion Energy Kewaunees Decommissioning Funding Status Report for Kewaunee Power Station, Docket No. 50-305 ML22290A0052022-10-13013 October 2022 Resubmittal of Kewaunee Power Station Independent Spent Fuel Storage Installation (ISFSI) Only Emergency Plan (Ioep) and IOEP- Emergency Action Level (EAL) Basis Document, Revision 0KS ML22241A0302022-08-25025 August 2022 (Ksp) ISFSI Submittal of Security Plan, Training and Qualification Plan and Safeguards Contingency Plan, Revision 5 IR 05000305/20220012022-08-0101 August 2022 NRC Inspection Report Nos. 05000305/2022001(DNMS) - Kewaunee Power Station ML22215A1512022-07-27027 July 2022 Executed Financial Assurance Instruments for the Kewaunee License Transfer License No. DPR-43 (Docket Nos. 50-305, 72-64) ML22209A1252022-07-26026 July 2022 Amendment No. 11 to Indemnity Agreement No. B-53 for Kewaunee Power Station (KPS) - Signed by Kewaunee Solutions, Inc ML22175A1132022-06-30030 June 2022 Solutions, Inc. - Letter for Review and Acceptance of the Energysolutions, LLC Decommissioning Quality Assurance Program with Enclosure ML22160A5272022-06-28028 June 2022 Enclosure 1 - Amendment No. 221 to Renewed Facility Operating License No. DPR-43 ML22160A5282022-06-28028 June 2022 Enclosure 2 - Amendment No. 11 to Indemnity Agreement B-53 ML22160A5262022-06-28028 June 2022 Letter - KPS - Issuance of Conforming License Amendment Regarding Indirect Transfer of License from DEK, Inc. to Kewaunee Solutions, Inc ML22188A0812022-06-23023 June 2022 ISFSI, Virgil C. Summer Nuclear Station, Unit 1 & ISFSI, North Anna Power Station, Units 1 & 2 & ISFSI, Surry Power Station, Units 1 & 2 & ISFSI - Submission of Revision 32 of the Quality Assurance Topical Report ML22172A2452022-06-22022 June 2022 Notification of Planned Closing Date and Required Regulatory Approvals for the Kewaunee License Transfer Transaction ML22175A0662022-06-17017 June 2022 Designation of Additional Reviewing Official for ISFSI and 10 CFR Part 37 Program Security Background Investigations ML22166A3392022-06-13013 June 2022 Notification of Nuclear Insurance ML22138A2552022-05-10010 May 2022 Submittal of 2021 Annual Radiological Environmental Operating Report ML22158A2112022-05-10010 May 2022 Summary of Facility Changes, Tests and Experiments and Summary of Commitment Changes ML22108A0352022-04-0101 April 2022 License Transfer to Kewaunee Solutions, Inc ML22091A1892022-04-0101 April 2022 Independent Spent Fuel Storage Installation - Annual Radioactive Effluent Release Report ML22089A2432022-03-30030 March 2022 Decommissioning Funding Status Report, Financial Test and Independent Public Accountants' Letter of Attestation ML22076A0652022-03-15015 March 2022 Energy Solutions and Dominion Energy Kewaunee - Supplement to License Transfer Application Related to Use of Existing Dominion Energy Quality Assurance Program ML22060A1912022-02-25025 February 2022 Response to Request for Additional Information Related to Submittal for Approval of the Kewaunee Solutions Decommissioning Quality Assurance Program (Dqap), Revision O for Kewaunee Power Station (KPS) ML22066A4982022-02-24024 February 2022 Nuclear Property Insurance Coverage ML22047A0572022-02-16016 February 2022 Supplement to License Transfer Application Related to Decommissioning Quality Assurance Program ML22032A3242022-02-0202 February 2022 Letter to C. Sly, Dominion, from B. Watson, NRC - Dominion Energy Kewaunee, Inc. - RAI Regarding Energysolutions Submittal for Approving Decommissioning Quality Assurance Program IR 05000305/20210012021-12-27027 December 2021 NRC Inspection Report Nos. 05000305/2021001 (Dnms); 07200064/2021001 (DNMS) ML21351A4352021-12-19019 December 2021 U.S. Nuclear Regulatory Commission'S Analysis of Dominion Energy Kewaunee, Inc.'S Decommissioning Funding Status Report for Kewaunee Power Station, Docket No. 50-305 ML21355A2972021-12-14014 December 2021 ISFSI, 10 CFR 72.30 Decommissioning Funding Plan ML21309A0152021-11-0909 November 2021 Acceptance Review of Dominion Energy Kewaunee, Inc. - Energysolutions Submittal for Approving Decommissioning Quality Assurance Program (EPID L-2021-DP3-0000) ML21301A1782021-10-28028 October 2021 Response to Request for Additional Information Regarding Application for Order Approving Transfer of Control of Kewaunee Power Station License and Conforming License ML21294A3652021-10-21021 October 2021 Changes to Decommissioning Trust Agreement ML21288A5572021-10-18018 October 2021 Energysolutions Submittal for Approving Decommissioning Quality Assurance Program (EPID L-2021-DP3-0000) ML21257A0682021-09-30030 September 2021 Request for Additional Information Regarding Application for Order Approving Transfer of Control of Kewaunee Power Station License and Conforming License Amendments ML21277A2462021-09-29029 September 2021 Resubmittal of Solutions Decommissioning Quality Assurance Program (Dqap), Revision 0 2024-01-26
[Table view] |
Text
May 8, 2006Mr. David A. ChristianSenior Vice President and Chief Nuclear Officer Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060-6711
SUBJECT:
KEWAUNEE POWER STATION - REQUEST FOR ADDITIONAL INFORMATIONRELATED TO EXTENSION OF SURVEILLANCE INTERVAL (TAC NO. MC9782)
Dear Mr. Christian:
By application for license amendment dated February 6, 2006, Dominion EnergyKewaunee, Inc., requested a license amendment to extend certain Technical Specification surveillance test intervals on a one-time only basis to account for the effects of an extended forced outage in the spring of 2005. In the course of the U.S. Nuclear RegulatoryCommission's review, it has been found to be necessary to request additional information.
Based upon discussions with your staff on April 18, 2006, we understand that you will res pondto the enclosed request for additional information within 30 days of the date of this letter.Sincerely, /RA/David H. Jaffe, Senior Project ManagerPlant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket No. 50-305
Enclosure:
Request for additional informationcc w/encls: See next page May 8, 2006Mr. David A. ChristianSenior Vice President and Chief Nuclear Officer Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060-6711
SUBJECT:
KEWAUNEE POWER STATION - REQUEST FOR ADDITIONAL INFORMATIONRELATED TO EXTENSION OF SURVEILLANCE INTERVAL (TAC NO. MC9782)
Dear Mr. Christian:
By application for license amendment dated February 6, 2006, Dominion EnergyKewaunee, Inc., requested a license amendment to extend certain Technical Specification surveillance test intervals on a one-time only basis to account for the effects of an extended forced outage in the spring of 2005. In the course of the U.S. Nuclear RegulatoryCommission's review, it has been found to be necessary to request additional information.
Based upon discussions with your staff on April 18, 2006, we understand that you will res pondto the enclosed request for additional information within 30 days of the date of this letter.Sincerely,/RA/
David H. Jaffe, Senior Project ManagerPlant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket No. 50-305
Enclosure:
Request for additional informationcc w/encls: See next pageDISTRIBUTION
- PUBLICLPL3-1 R/FRidsNrrDorlLpleRidsNrrPMDJaffe RidsNrrLATHarrisRidsOgcRpRidsAcrsAcnwMailCenterRidsNrrDirsltsb RidsRgn3MailCenterRidsNrrDorlDprADAMS Accession Number: ML060950233OFFICENRR/LPL3-1/PMNRR/LPL3-1/LANRR/LPL3-1/BC NAMEDJaffe:rsaTHarrisLRaghavan DATE5/5/065/4/065/8/06OFFICIAL RECORD COPY Kewaunee Power Station cc:
Resident Inspectors OfficeU.S. Nuclear Regulatory Commission N490 Highway 42 Kewaunee, WI 54216-9510Regional Administrator, Region IIIU.S. Nuclear Regulatory Commission Suite 210 2443 Warrenville RoadLisle, IL 60532-4351David ZellnerChairman - Town of Carlton N2164 County B Kewaunee, WI 54216Mr. Jeffery KitsembelElectric Division Public Service Commission of Wisconsin PO Box 7854 Madison, WI 53707-7854Mr. Michael G. GaffneyDominion Energy Kewaunee, Inc.
Kewaunee Power Station N490 Highway 42 Kewaunee, WI 54216Mr. Chris L. FunderburkDirector, Nuclear Licensing and Operations Support Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060-6711Mr. Thomas L. BreeneDominion Energy Kewaunee, Inc.
Kewaunee Power Station N490 Highway 42 Kewaunee, WI 54216Ms. Lillian M. Cuoco, Esq.Senior Counsel Dominion Resources Services, Inc.
Millstone Power StationBuilding 475, 5th Floor Rope Ferry Road Waterford, CT 06385Plant ManagerKewaunee Power Station N490 Highway 42 Kewaunee, WI 54216-9511 ENCLOSUREREQUEST FOR ADDITIONAL INFORMATION REGARDING KEWAUNEE POWER STATION EXTENDED SURVEILLANCE INTERVALEEEB1.Concerning Technical Specification (TS) 4.6.a.2, discuss any plans for pre-testmaintenance of the emergency diesel generators.EEEB2.Describe the corrective actions taken for the 1996 event described on page 31 ofthe submittal.EEEB3.Concerning TS 4.6.a.3, describe the procedure deficiencies and equipment failuresidentified in your previous performance review, include a discussion of the corrective actions taken for these deficiencies and failures.EEEB4. Concerning TS 4.6.a.4, discuss the procedure deficiencies and equipment failuresidentified in your previous performance review, include a discussion of the corrective actions taken for these deficiencies and failures.EEEB5.Discuss whether there are any other surveillance requirements (SR) that will beperformed during the extended SR interval, that will help ensure that the equipmentwill function as int ended.CPTB1.Regarding the program for inservice inspection and testing of snubbers, isKewaunee using TS Section 4.14, American Society of Mechanical Engineers/American National Standards Institute, OM Part 4, or a combination from both of these sources.CPTB2.Kewaunee TS 4.14 only provides inservice inspection and testing requirements forhydraulic snubbers. Please verify that there are no mechanical snubbers at Kewaunee. CPTB3.In the request for relief from Code Requirements, the licensee states that all Code1, 2 and 3 small bore hydraulic snubbers received visual examination except RC-H72 during the forced shutdown of November 2005. How many of these, or any other, snubbers failed this examination?EICB1.The Section 4.0, Technical Analysis, Attachment 1, of the License AmendmentRequest records Analytical Limit, Total Loop Error, TS Limit, Margins, Allowable Value, Actual Plant Setting, Loop Drift, and Calibration Tolerance used and/or derived using Kewaunee Power Station nuclear administrative directive (NAD) NAD 4.6, Plant Setpoint Accuracy, for Pressurizer Level High Reactor Trip Instrumentation. Provide similar information for all the functions in Tables 4.1-1 and 4.1-3 for which similar evaluations have been performed.