IR 05000334/2011004; 05000412/2011004; 07/01/2011-09/30/2011; Beaver Valley Power Station, Units 1 and 2; Routine Integrated Report
ML11306A204
Person / Time
Site: Beaver Valley
Issue date: 11/02/2011
From: DiPaolo E M
NRC/RGN-I/DRP/PB6
To: Harden P A
FirstEnergy Nuclear Operating Co
DiPaolo E M
References
IR-11-004
Download: ML11306A204 (25)


Text

{ffi UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 475 ALLENDALE ROAD KING OF PRUSSIA. PENNSYLVANIA 19406.1415 November 2, 20LI+**ti Mr. Paul Site Vice President FirstEnergy Nuclear Operating Company Beaver Valley Power Station P. O. Box 4, Route 168 Shippingport, PA 15077

SUBJECT: BEAVER VALLEY POWER STATION - NRC INTEGRATED INSPECTION RE PO RT 05000334/20 1 1 004 AN D 05000 41 21 20 1 1 00 4

Dear Mr. Harden:

On September 30, 2011, the U. S. Nuclear Regulatory Commission (NRC) completed an inspection at your Beaver Valley Power Station Units 1 and 2. The enclosed integrated inspection report documents the inspection results, which were discussed on October 12, 2011, with you and other members of your staff.The inspection examined activities conducted under your license as they relate to safety and compliance with the Commission's rules and regulations and with the conditions of your license.The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel.

Based on the results of this inspection, no findings were identified.

In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter, and its enclosures, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Website at http://www.nrc.oov/readinq-rm/adams.html (the Public Electronic Reading Room). We appreciate your cooperation.

Please contact me at 610-337-5200 if you have any questions regarding this letter.

Sincerely,4^_-/rL.+-/r4 Eugene M. DiPaolo, Acting Chief Reactor Projects Branch 6 Division of Reactor Projects Docket Nos.: 50-334, 50-412 License Nos: DPR-66, NPF-73

Enclosures:

Inspection Report 05000334/2UfiA4; 0500041 212011004 M

Attachment:

Supplemental Information cc w/encl: Distribution via ListServ Mr. Paul Site Vice President FirstEnergy Nuclear Operating Company Beaver Valley Power Station P. O. Box 4, Route 168 Shippingport, PA 15077 November 2,2011

SUBJECT: BEAVER VALLEY POWER STATION - NRC INTEGRATED INSPECTION REPORT 05000334/201 1004 AND 05000412t201 1001

Dear Mr. Harden:

On September 30, 2011, the U. S. Nuclear Regulatory Commission (NRC) completed an inspection at your Beaver Valley Power Station Units 1 and 2. The enclosed integrated inspection report documents the inspection results, which were discussed on October 12,2011, with you and other members of your staff.The inspection examined activities conducted under your license as they relate to safety and compliance with the Commission's rules and regulations and with the conditions of your license. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel.

Based on the results of this inspection, no findings were identified.

In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter, and its enclosures, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Website at http:i/www.nrc.qov/readinq-rmiadams.html (the Public Electronic Reading Room). We appreciate your cooperation.

Please contact me at 610-337-5200 if you have any questions regarding this letter.

Sincerely,/RA/Eugene M. DiPaolo, Acting Chief Reactor Projects Branch 6 Division of Reactor Projects Docket Nos.: 50-334, 50-412 License Nos: DPR-66, NPF-73

Enclosures:

Inspection Report 05000334/2011004; 0500041212011004 M

Attachment:

Supplemental lnformation cc w/encl: Distribution via ListServ Distribution Wencl: S. Barber, DRP W. Dean, RA A. Dugandzic, DRP D. Lew, DRA N. Lafferty, DRP D. Roberts, DRP D. Spindler, DRP, SRI D. Ayres, DRP E. Bonney, DRP, Rl E. DiPaolo, DRP P. Garrett, DRP, OA SUNSIReview Gomplete:

EMD (Reviewer's lnitials)DOCUMENT NAME: G:\Sites\B\Alnspection Reports\2011-004 (3rd qtr)\BV_Report_1R2011-004.docx After declaring this document "An Offlcial Agency Record" it will be released to the Public.M. Franke, RIOEDO RidsN RRPM BeaverValley Resource RidsNRRDorlLpl 1 -1 Resource ROPreports Resource M111306A204 To receive a copy of lhis document, indicate in the box:'C' = Copy without.E' = Coov with attachmenuenclosure "N" = N0 OFFICE /hp RI/DRP RI/DRP RI/DRP NAME Soindler/emd for ADuoandzic/emd for EDiPaolo/emd DATE 10t 31 t't1 10t31t11 11102t11 OFFICIAL RECORD COPY Docket Nos.License Nos.Report Nos.Licensee: Facility: Location: Dates: Inspectors:

Approved by: 1 U. S. NUCLEAR REGULATORY COMMISSION REGION I 50-334, 50-412 DPR-66, NPF-73 05000334/201 1 004 and 05000 41 21 2U I OA4 FirstEnergy Nuclear Operating Company (FENOC)Beaver Valley Power Station, Units 1 and 2 Shippingport, PA 15077 July 1 ,2011through September 30,2011 D. Spindler, Senior Resident Inspector E. Bonney, Resident InsPector T. Moslak, Sr. Health Physicist (DRS)J. Brand, Reactor lnsPector (DRS)T. Burns, Sr. Reactor lnspector (DRS)Eugene M. DiPaolo, Acting Chief Reactor Projects Branch 6 Division of Reactor Projects Enclosure 2 TABLE of

SUMMARY OF FINDINGS

tR 0500033 4t2011004, tR 0500041 2l2o11OO4;

A710112011 - 0913012011;

Beaver Valley Power Station, Units 1 & 2; Routine Integrated Report The report covered a 3-month period of inspection by resident inspectors, regional reactor inspeciors, and a regional health physics inspector.

The NRC's program for overseeing the safe operation of commercial nuclear power reactors is described in NUREG-1649, "Reactor Oversight Process," Revision 4, dated December 2006.No findings were identified.

REPORT DETAILS

Summarv of Plant Status: Unit 1 began the inspection period at 100 percent power. On July 21 , the unit was down-powered to 94 percent due to condenser hotwell temperature limitations during hot weather conditions and returned to full power on July 22. The unit remained at 100 percent power for the remainder of the inspection period.Unit 2 began the inspection period at 100 percent power and remained at full power throughout the inspection period.1. REAGTORSAFETY

Cornerstone:

Initiating Events, Mitigating Systems, Barrier Integrity

[R]1R01 Adverse Weather Protection (71111.01 - 1 sample).1 Seasonal Susceptibilitv

a. Inspection Scope

The inspectors reviewed hurricane readiness of Unit 1 and Unit 2 river water/service water systems for extreme weather conditions; specifically, hurricanes, high winds, high water level, and other relevant severe weather events. The inspection verified that the indicated equipment, its instrumentation, and supporting structures were configured in accordance with FENOC's procedures and that adequate controls were in place to ensure functionality of the system. The inspectors reviewed licensee procedures and walked down the system. Documents reviewed for each section of this inspection report are listed in the Attachment.

b. Findinqs No findings were identified.

1R04 Equipment

Aliqnment.1 Partial Svstem Walkdowns (71111.04Q - 3 samples)a. Inspection Scope The inspectors performed three partial equipment alignment inspections during conditions of increased safety significance, including when redundant equipment was unavailable during maintenance or adverse conditions.

The partial alignment inspections were also completed after equipment was recently returned to service after significant maintenance.

The inspectors performed partial walkdowns of the following syltems, including associated electrical distribution components and control room panels, to verify the equipment was aligned to perform its intended safety functions:

5. Unit 1, 'A' Motor driven Auxiliary

Feed Water (AFW) pump and turbine driven AFW pump during testing of the 'B' motor driven AFW pump on August 10 o Unit 2,'A'Train Service Water System (SWS) lineup during'B'train SWS Limiting Condition for Operation (LCO) entry on August 15. Unit 2, 125 Volt batteries (2-1 ,2-2, and 2-3) during 2-4battery individual cell voltage degradation on August 11 b. Findinqs No findings were identified.

1R05 Fire Protection

.1 Quarterlv

Sample Review (71111.05Q - 5 samples)a. Inspection Scope The inspectors reviewed the conditions of the fire areas listed below, to verify compliance with criteria delineated in Administrative Procedure 112-ADM-1900, "Fire Protection," Rev. 23. This review included FENOC's control of transient combustibles and ignition sources, material condition of fire protection equipment including fire detection systems, water-based fire suppression systems, gaseous fire suppression systems, manual firefighting equipment and capability, passive fire protection features, and the adequacy of compensatory measures for any fire protection impairments.. Unit 1, Relay Room (Fire Area CR-3). Unit 1, Process Rack Room (Fire Area CR-4). Unit 1, Battery Rooms 1&3 (Fire Area ES-1). Unit 1, Control Room HVAC Equipment Room (Fire Area CR-2). Unit 2, Fuel Building (Fire Area FB-1)b. Findinqs No findings were identified.

1R06 Flood Protection

Measures (71111.06 - 1 sample)a. lnspection Scope The inspectors reviewed a sample of internal flood protection measures for equipment in Unit 2, 2-2 and 2-4 Battery Rooms.This review was conducted to evaluate FENOC's protection of the enclosed safety-retated systems from internalflooding condition.

The inspectors performed a walkdown of the area, reviewed the UFSAR, related internal flooding evaluations, and other related documents.

The inspectors examined the as-found equipment and conditions to ensure that they remained consistent with those indicated in the design basis documentation, flooding mitigation documents, and risk analysis assumptions.

6 b. Findinqs No findings were identified.

1R1 1 Licensed Operator Requalification Proqram (71111.11)

.1 Resident Inspector

Quarterlv Review (71111.11Q - 1 sample)a. Inspection Scope The inspectors observed a sample of Unit 1 licensed operator simulator training on August 18. The inspectors evaluated licensed operator performance regarding command and control, implementation of normal, annunciator response, abnormal, and emergency operating procedures, communications, technical specification review and compliance, and emergency plan implementation.

The inspectors evaluated the licensee staff training personnel to verify that deficiencies in operator performance were identified, and that conditions adverse to quality were entered into the licensee's corrective action program for resolution.

The inspectors reviewed simulator physical fidelity to assure the simulator appropriately modeled the plant control room. The inspectors verified that the training evaluators adequately addressed that the applicable training objectives had been achieved.b. Findinqs No findings were identified.

1R12 Maintenance

Effectiveness (71111.12-1 sample)a. Inspection Scope The inspectors evaluated Maintenance Rule (MR) implementation for the issues listed below. The inspectors evaluated specific attributes, such as MR scoping, characterization of failed structures, systems, and components (SSCs), MR risk characterization of SSCs, SSC performance criteria and goals, and appropriateness of corrective actions. The inspectors verified that the issues were addressed as required by 10 CFR 50.65 and the licensee's program for MR implementation.

For the selected S-SCs, the inspectors evaluated whether performance was properly dispositioned for MR category (aX1) and (a)(2) performance monitoring.

MR System Basis Documents were also reviewed, as apProPriate.. 2ASystem Station Service Transformer (SSST) availability monitoring during tap changer rePair.b. Findinqs No findings were identified.

7 1R13 Maintenance RiskAssessmentand EmerqentWork Control (71111.13-4samples)a. Inspection Scope The inspectors reviewed the scheduling and control of maintenance activities, and evaluated their effect on overall plant risk. This review was conducted to ensure compliance with applicable criteria contained in 10 CFR 50.65(a)(4).

r Unit 1, CR 11-98009, "Probabilistic Risk Assessment (PRA) not performed prior to clearance posting on PRA component" on July 21. Unit 1, PRA late update to control room on August 1. Unit 1 and Unit 2, Maintenance risk assessment during a hot weather alert the week of July 18. Unit 2, 'A' Component cooling water (CCP) pump maintenance activities window extended and associated PRA review on September 20 b. Findinos No findings were identified.

1R15 Operabilitv

Evaluations (71111.15-6 samples)a. Inspection Scope The inspectors evaluated the technical adequacy of selected immediate operability determinations (lOD), prompt operability determinations (POD), or functionality assessments (FA), to verify that determinations of operability were justified.

In addition, the inspectors verified that technical specification (TS) limiting conditions for operation (LCO) requirements and UFSAR design basis requirements were properly addressed.

ln addition, the inspectors reviewed compensatory measures implemented to ensure the measures worked and were adequately controlled.

o Unit 1, Urgent rod control alarm during Rod Insertion testing, CR 2011-00582 r Unit 1, Turbine driven auxiliary feedwater pump [1FW-P-2]

high oil level in outboard bearing as documented in CR '11-97241. Unit 1, Part 21 evaluation of installed Velan globe valve, CR 1 1 -97892 o Unit 2, Primary component cooling water pumps oil bubbler design and level settling as documented in wos 20011932000, 20011933000, 20011933000, and 200028524 o Unit 2, 'B' SWS line pinhole leak prompt operating determination, as documented in cR 2011-00581 o Unit 2, 2A SSST Manual tap changer relay function restoration to exit TS LCO 3.8.1 b. Findinqs No findings were identified.

I 1R18 Plant Modifications (71111.18 - 1 sample)a. Inspection Scooe The inspectors reviewed the following permanent and temporary modifications based on risk significance.

The permanent modifications and associated 10 CFR 50.59 screenings were reviewed against the system design basis documentation, including the UFSAR and the TS. The inspectors verified that attributes and parameters within the design documentation were consistent with required licensing and design bases, as well as credited codes and standards, and walked down the systems to verify that changes described in the package were appropriately implemented.

The inspectors verified the temporary modifications were implemented in accordance with Administrative (ADM)Procedure, 112-ADM-2028, "Temporary Modifications," Rev. 6. The inspectors also verified the post-modification testing was satisfactorily accomplished to ensure the system and components operated consistent with their intended safety function.o Engineering Change Package 11-0426-00,1-2 Emergency diesel generator (EDG)Start on Loss of Voltage relay replacement b. Findinqs No findings were identified.

1R19 Post-Maintenance

Testino (71111.19 - 4 samples)a. Inspection Scope The inspectors reviewed the activities listed below to determine whether the post-maintenance tests (PMT) adequately demonstrated that the safety-related function of the equipment was satisfied given the scope of the work, and that operability of the system was restored.

In addition, the inspectors evaluated the applicable acceptance criteria to verify consistency with the design and licensing bases, as well as TS requirements.

The inspectors witnessed the test or reviewed test data to verify results adequately demonstrated restoration of affected safety functions.

The inspectors also verified that conditions adverse to quality were entered into the corrective action program for resolution.. Unit 1, 1-2 EDG Undervoltage start relay replacement o Unit 2,2A SSST Tap charger rePair o Unit 2, Turbine driven auxiliary feedwater pump I2FWE-P221 trip throttle valve stem coupling repair o Unit 2, 2-4125 Volt battery jumper installation, 2MSP-E-39-300, Vital Bus Weekly Battery Inspection b. Findinqs No findings were identified.

I 1R22 Surveillance Testinq (71111.22 - 7 samples)a. Inspection Scope The inspectors witnessed the performance of or reviewed test data for the seven Operation Surveillance Test (OST) and Maintenance Surveillance (MSP) packages listed below. The reviews verified that the equipment or systems were being tested as required by TS, the UFSAR, and procedural requirements.

The inspectors also verified that the licensee established proper test conditions, that no equipment pre-conditioning activities occurred, and that acceptance criteria were met.. Unit 1 , l 05T-36.2, Diesel Generator No. 2 Monthly Test on August 3 (in-service test)o Unit 1 , l OST-13.2, Quench Spray Pump [1OS-P-1 B] Test on August 4. Unit 1, lOSf -24.3, Motor Driven Auxiliary Feed Pump Test [1FW-P-3B]

on August 10 o Unit 2, 2OST-30.2, Service Water Pump [25SWS.P21A]

Test on August 25. Unit 2,2OST-15.2, Primary Component Cooling Water Pump I2CCP*P21BI Test on July 17. Unit 2,2OST-1.128, Safeguards Protection System Train 'B' SIS Test on August 3 o Unit 2,2OST-13.1, Quench Spray Pump [2QSS*P21A]

Test on September 22 b. Findinqs No findings were identified.

Gornerstone:

Emergency Preparedness

[EP]1EP6 Drill Evaluation (71114.06 - 1 sample)a. Inspection Scope The inspectors observed an emergency preparedness mini-drill and Unit 1 licensed-operator simulator evaluation on August 18. Senior licensed-operator performance regarding event classifications and notifications were specifically evaluated.

The inspectors evaluated the simulator-based scenario that involved multiple, safety-related component failures and plant conditions that would have warranted emergency plan activation, emergency facility activation, and escalation to the event classification of Alert. The licensee planned to credit this evolution toward Emergency Preparedness Drill/Exercise Performance (DEP) Indicators, therefore, the inspectors reviewed the applicable event notifications and classifications to determine whether they were appropriately credited, and properly evaluated consistent with Nuclear Energy Institute (NEl) gg-02, Rev. 6, "Regulatory Assessment Performance Indicator Guideline." The inspectors reviewed licensee evaluator worksheets regarding the performance indicator acceptability, and reviewed other crew and operator evaluations to ensure adverse conditions were appropriately entered into the Corrective Action Program. Other documents utilized in this inspection include the following:. 112-ADM-1 1 1 1, Rev. 4, "NRC EPP Performance Indicator lnstructions". 112-ADM-1111.F01, Rev. 3, "Emergency Preparedness Performance Indicators Classifications/Notifications/PARS" o EpP-l-1a/b, Rev. l4, "Recognition and Classification of Emergency Conditions;". 112-EPP-l-2, Rev. 35, "Unusual Event" Enclosure 10. 112-EPP-l-3, Rev. 33, "Alert". 112-EPP-l-4, Rev. 33, "Site Area Emergency" and. 112-EPP-I-5, Rev. 34, "General Emergency" b. Findinqs No findings were identified.

2. RADIATION

SAFETY Gornerstone:

Public Radiation Safety [RS]2RS07 Radioloqical Environmental Monitorinq Proqram (REMP) (71124.07 - 1 sample)a. Inspection ScoPe During the period July 1 8 - 21,2011, the inspector conducted the following activities to verifylhat the licensee implemented the radiological environmental monitoring program (REMP) consistent with the Site Technical Specifications and the Off-Site Dose Calculation Manual (ODCM) to validate that radioactive effluent releases met the design objectives of Appendix I to 10 CFR Part 50.This inspection activity represents completion of one

(1) sample relative to this inspection area.REMP Inspections:

The inspector reviewed the 2009 and 2010 Annual Radiological Environmental Operating Reports and the 2010 REMP Land Use Census Report to verify that the environmental monitoring programs were implemented as required by the ODCM.The inspector walked down nine (of ten) air sampling stations (Nos. 13, 27, 28, 29B, 30, 32, 46.1, 47, S1), two (of three) milk sampling stations (Nos. 25, 96), three (of three)surface water sampling stations (Nos. 2.1, 5, 49A), two (of two) drinking water stations (Nos. 4, 5), and seventeen (of fifty) thermoluminescent (TLD) monltoryg stations (ttos. t0, i3, i4, 15, 27, 28',298; 30, 32, 45, 45.1, 46, 46.1, 47,51, 60, 72) to determine if sampling was conducted as described in the ODCM and associated procedures, and to evaluate the sampling equipment material condition' As part of the walkdown, the inspector observed the technician collect and prepare for analysis air particulate/iodine filter samples, milk samples, and water samples; and verified that environmental sampling was representative of the release pathways as specified in the ODCM, and that sampling techniques were in accordance with approved procedures.

Based on direct observation and review of records, the inspector verified that the primary and redundant meteorological instrumentation was operable, calibrated, and maintained in accordance with the gu'rdance contained in the UFSAR, NRC Regulatory Guide 1'23, , and the licensee procedures.

The inspector verified that the meteorological data readout and recording insiruments in the control room and at the tower were operable for wind direction, win-d speed, and delta temperature.

The inspector confirmed that redundant instrumentation was oPerable.Enclosure 11 The inspector reviewed the calibration and maintenance records for ten

(10) air samplers and observed the technician verifying the calibration of three water compositors.

The inspector reviewed Condition Reports, a Nuclear Oversight audit report (MS-C-10-08-02), and Nuclear Oversight field observation reports, addressing implementation of REMP requirements, to evaluate the threshold for which issues are entered into the corrective action program, the adequacy of subsequent evaluations, and the effectiveness of the resolution.

The inspector also reviewed monthly RETS/ODCM effluent occurrence reports to evaluate the adequacy and timeliness of performance indicator information.

The inspector reviewed the results of the licensee's quarterly laboratory cross-check program to verify the accuracy of the licensee's environmental air filter, charcoal cartridge, water, and milk sample analyses.The inspector reviewed changes made by the licensee to the ODCM as a result of changes to the land use census or sampler station modifications since the last inspection.

The inspector also reviewed technicaljustifications for any change in sampling location (or frequency)and verified the licensee performed the reviews required to ensure that the changes did not affect its ability to monitor the radiological condition of the environment.

The inspector walked down the on-site groundwater monitoring wells and discussed programmatic enhancements that are being made in identifying and controlling spills/leaks to groundwater with the Chemistry Department Manager.b. Findinqs No findings were identified.

OTHER ACTIVITIES

IOAI

4OA1 Performance

lndicator Verification (7 1 151).1 Mitiqatinq Svstem Performance lndex (6 samples)a. lnspection Scope The inspectors reviewed FENOC's submittal of the Mitigating Systems Performance Index for the following systems for the period of September 1 , 2010 through August 31, 2011:. Unit 1 Auxiliary Feedwater System. Unit 1 Residual Heat Removal System. Unit 1 Support Cooling Water System o Unit 2 Auxiliary Feedwater System. Unit 2 Residual Heat Removal System. Unit 2 Support Cooling Water System Enclosure a.12 To determine the accuracy of the performance indicator data reported during those periods, the inspectors used definitions and guidance contained in NEI Document 99-02,"Regulatory Assessment Performance Indicator Guideline," Revision 6. The inspectors also reviewed FENOC's operator narrative logs, condition reports, mitigating systems performance index derivation reports, event reports and NRC integrated inspection reports to validate the accuracy of the submittals.

Occupational Exposure Control Effectiveness (1 sample)lnspection Scope The inspector reviewed implementation of the licensee's Occupational Exposure Control Effectiveness Performance Indicator (Pl) Program. Specifically, the inspector reviewed condition reports, and associated documents, for occurrences involving locked high radiation areas, very high radiation areas, and unplanned exposures against the criteria specified in Nuclear Energy lnstitute (NEl) 99-02, Regulatory Assessment Performance lndicator Guideline, to verify that all occurrences that met the NEI criteria were identified and reported as performance indicators.

This inspection activity represents the completion of one

(1) sample relative to this inspection area; completing the annual inspection requirement.

Findinqs No findings were identified.

RETS/ODCM Radioloqical Effluent Occurrences (1 sample)lnspection Scope The inspector reviewed relevant effluent release reports for the period April 1 ,2010 through June 1 ,2011, for issues related to the public radiation safety performance indicator, which measures radiological effluent release occurrences that exceed 1.5 mrem/quarter whole body or 5.0 mrem/quarter organ dose for liquid effluents; 5 mrads/quarter gamma air dose, 10 mrad/quarter beta air dose, and 7.5 mrads/quarter for organ dose for gaseous effluents.

This inspection activity represents the completion of one

(1) sample relative to this inspection area; completing the annual inspection requirement.

Findinqs No findings were identified.

Problem ldentification and Resolution (71152 - 2 samples)Routine Review of Problem ldentification and Resolution Activities lnspection Scope As required by Inspection Procedure71152, "Problem ldentification and Resolution," the inspectors routinely reviewed issues during baseline inspection activities and plant status reviews to verify that FENOC entered issues into the corrective action program at an appropriate threshold, gave adequate attention to timely corrective actions, and Enclosure.3 a.b.4c.42.1 a 13 identified and addressed adverse trends. In order to assist with the identification of repetitive equipment failures and specific human performance issues for followup, the inspectors performed a daily screening of items entered into the corrective action program and periodically attended condition report screen meetings.Findinqs No findings were identified.

Semi-Annual Trend Review Inspection Scope The inspectors reviewed site trending results for the time period January through June 2011, to determine if trending was appropriately performed and evaluated by FENOC.This review covered the site trending program under FENOC's Integrated Performance Assessment process, and included a sample of self-assessments from the several organizations at Beaver Valley. This review verifies that existing trends were (1)appropriately captured and scoped by applicable departments,

(2) consistent with the inspectors' assessment from the daily CR and inspection module reviews and
(3) not indicative of a more significant safety concern. Additionally, the inspectors verified the performance of site trending against NOP-LP-2001, Rev. 23, "Condition Report Process," and NOBP-LP-2018, Rev. 05, "lntegrated Performance Assessment

/Trending." The inspectors also reviewed quarterly Quality Assurance reports and issues captured in the Activity Tracking database to identify issues and trends to evaluate during the inspection.

Findinqs and Observations No findings were identified.

However, an adverse trend was identified regarding procedure usage by operations and maintenance personnel.

Three specific instances of inadequate procedural adherence were noted. One instance resulted in an inadvertent auxiliary feedwater injection at power (CR 1 1-97132).

A second instance resulted in lost data gathered during surveillance testing because procedural steps were marked "N/A" (CR 11-97062).

Athird instance resulted in an inadvertent actuation of Unit 2 auxiliary feedwater while shutdown (CR 11-90528).

The licensee has identified a trend in inadequate procedure usage and has entered the issue into the corrective action process (CR 11-97126).

Annual Sample: Review of On-Line Risk Assessment and Manaqement Inspection Scooe The inspectors reviewed FENOC CRs related to PRA components and, combinations of components removed from service and thereby unavailable during the scheduled work week. The CRs were evaluated for accuracy and comprehensiveness of problem identification, thoroughness of cause determination and effectiveness and timeliness of corrective actions Twelve CRs were evaluated for compliance with NOP-OP-1007, Revision 10, "Risk Management",ll2ADM-2003, Revision 4, "Risk Management Program", and %-ADM-0804, Revision 9, "On-line Risk Assessment and Management".

ln addition to the Enclosure b.14 documentation review, the inspectors interviewed the On Line Work Week Manager and PRA Analyst to assess overall coordination and management of scheduled activities involving PRA components to effectively manage plant risk.Findinqs and Observations No findings were identified.

The inspectors determined that the implementation of the"Risk Management Program" was being managed to effectively apply the PRA modelto risk management decision making to ensure that planned work activities on PRA components have been evaluated for PRA impact.Followup of Events and Notices of Enforcement Discretion (71153 - 3 samples)Plant Event Review Inspection Scope For the plant events below, the inspectors reviewed and/or observed plant parameters, reviewed personnel performance, and evaluated performance of mitigating systems.The inspectors communicated the plant events to regional personnel and compared the event details with criteria contained in IMC 0309, "Reactive Inspection Decision Basis for Reactors," for consideration of additional reactive inspection activities.

As applicable, the inspectors verified that FENOC made appropriate emergency classification assessments and properly reported the event in accordance with 10 CFR Parts 50.72 and 50.73. The inspectors reviewed FENOC's follow-up actions related to the events to assure that FENOC implemented appropriate corrective actions commensurate with their safety significance.. Abnormal Operating Procedure 1/2OM-53C.4A.75.3, Acts of Nature- Earthquake, entry and followup on August 23 due to seismic activity Findinqs No findings were identified.(Closed) Licensee Event Report 05000412/2011-002-00:

Auxiliary Feedwater System Vent Line Weld Crack Results in Technical Specification Required Plant Shutdown and Valid Reactor Protection System/Engineered Safety Feature Actuation System Actuations On April g,2011, FENOC discovered an active leak during power ascension on the 'A'steam generator (SG) feedwater injection header, which involved entry into TS 3.7.5.During-the TS required shutdown, 'A' SG water level reached a low level requiring a reactor trip. The inspectors determined that no new findings of significance were identified isee 1R0500041212011009 NCV 05000334, 41212011009-01)'

This LER is closed.(Closed) Licensee Event Report 05000412/2011-003-09:

Automatic Actuation of Standby Sen tce Water Pumps Following Unexpected Service Water Pump Trip On June 10,2011, the in-service

'A' service water pump motor failed, resulting in the automatic start of the 'A' and 'B' standby service water pumps due to low service water 40A3.1 a.b..2.3 Enclosure 40A6 15 header pressure.

The inspectors determined that no new findings of signiflcance were identified (see 1R0500041212011009 NCV 0500041212011009-02).

This LER is closed.Manaqement Meetinqs Radioloqical Environmental Monitorinq Proqram (REMP)The inspector presented the inspection results of 2RS07 to Dan Murray, Director of performance lmprovement, and other members of FENOC staff, at the conclusion of the inspection on July 21. No proprietary information is presented in this report'Quarterlv Inspection RePort Exit On October 12, the inspectors presented the normal baseline inspection results to Paul Harden. Site Vice President, and other members of the licensee staff. The inspectors confirmed that proprietary information was not retained at the conclusion of the inspection period..1 ATTACHMENT:

SUPPLEMENTAL I NFORMATION Licensee personnel S. Baker M. Banko G. Cacciani S. Checketts R. Dinello R. Ferrie B. Furdak R. Groggett P. Harden G. Henzler L. Huyler D. Jones M. Kienzle M. Librich R. Lieb R. Lubert C. Makawka M. Manolarus J. Mauck D. McBride C. McFeaters T. McGourty J. Miller M. Mitchell D. Murray D. Neidlinger A. Reardon J. Redmond L. Renz D. Salera D. Schwer B. Sepelak B. Tuite Other Personnel L. Ryan A-1

=SUPPLEMENTAL

INFORMATION=

KEY POINTS OF CONTACT

Radiation

Protection

Manager Environmental

& Chemistry

Supervisor

Design Engineer Operations

Manager Environmental

Field Specialist

Supervisor, Nuclear Relay Maintenance

Fleet Oversight

Assessor Advanced Nuclear SPecialist

Site Vice President lnstrumentation

& Control Technician

Advanced Nuclear Specialist

Staff Nuclear Engineer AFW System Engineer Reactor Operator Director, Site Operations

Supervisor, Electrical

Design Staff Nuclear Specialist

Director of Engineering

Regulatory

Compliance

Fleet Oversight

Manager Manager, Operations

Flood Program Engineer Fire Marshall Supervisor, Work Planning Director, Performance

lmprovement

Senior Quality Technician

Staff Nuclear Engineer Staff Nuclear Engineer Advanced Nuclear SPecialist

Chemistry

Supervisor

Superintendent, Operations

Services Supervisor, Regulatory

ComPliance

Manager, RegulatorY

ComPliance

Inspector, Pennsylvania

Department

of Radiation

Protection

LIST OF ITEMS OPENED, CLOSED, AND DISCUSSED

Closed

05000334/2010002-01
0500041 212011002-00
050004121201
1003-00 LER LER LER 270 Degree Circumferential
Flaw Found on Residual Heat Removal System Drain Valve Socket Weld (lR
05000334/2011002
Section 4OA3)Auxiliary
Feedwater
System Vent Line Weld Crack Results in Technical
Specification
Required Plant Shutdown and Valid Reactor Protection
System/Engineered
Safety Feature Actuation System Actuations (Section 4OA3)Automatic
Actuation

of Standby Service Water Pumps Following

Unexpected
Service Water Pump Trip (Section 4OA3)

LIST OF DOCUMENTS

REVIEWED

Section 1R01: Adverse Weather Protection

Procedures

1/2
OM-53C.4A.75.2, Acts of Nature- Flood, Revision 28 1/2
OM-53C.4A.75.4, Acts of Nature- Dam Failure, Revision 7 112
OM-53C.4A.75.1, Acts of Nature- Tornado or High Winds Condition, Revision 13

Section 1R04: Equipment

Aliqnment Procedures
2OM-30.3.B.1, Valve List-2SWS, Revision 39 lOST-42.3, Motor Driven Auxiliary Feedwater Pump Test [1FW-P-38], Revision 42 1OM-24.3.B.1, U-1, Valve List-1FW, Revision 19 Drawinqs
RM-0430-002, Revision 40
RM-0424.002, Revision 13
RM-0424-001, Revision 17 Condition Reports 2011-00581
11-97157 10-46791 08-47692 Other NRC Letter dated
912712007, Beaver Valley Unit No. 1 Relief Request Regarding the Fourth 10-Year Inservice Testing Program Relief Requests Inservice Testing (lST) Program for Pumps and Valves, Pump Relief Request 9, Revision 7 ASME OM Cod-2001, subsection lstB 1FW-P-2, Pump Curve Pre-Job Briefing Checklist, Brief #43,
FW-P-38 Surveillance Test System Health Report, System 248-SEEBV-1-24
System Unit 1 Auxiliary
FE
MAP-1
BV-25, Electrical Equipment Qualification Maintenance Assessment, Revision 19 Attachment Section 1R05: Fire Protection Pre-Fire Plans lPFP-SRVB-713-Relay Room Fire Area
CR-3 l
PFP-SRVB-713-Process Rack Room Fire Area
CR-4 2PFP-FULB-735-766-Fuel Building Fire Area
FB-1 l
PFP-SRVB-713-Control Room HVAC Equipment Room
CR-2 lPFP-SRVB-713-Battery Rooms 1&3, Fire Area
ES-1 Work Orders 20a341607
200472310
200474400 Other
NOBP-OP-gg15-04, Daily Status Report, Fire Protection System Status, dated
712712011, Revision 01 1OM-568.4.C, Safe Shutdown Following

a Serious Fire In The Control Building, Revision 9 1/2

PMP-33FP-Fire Doors-lM, Periodic Inspection of Fire Doors, Revision 5 10080-DMC-3443,
GL 86-1OEvaluation of Excessive Clearances Between Fire Rated Doors and Frames, Revision 0 lOST-33-35, Fire Rated assemblies Visual Inspection, Revision 2 cR 2001-01136

Section 1R06: Flood Protection

Procedures

2
OM-53C.4A.75.2, Acts of Nature- Flood, Revision 28 1/2
OM-53C.4A.75.4, Acts of Nature- Dam Failure, Revision 7 1/2
OM-53C.4A.75.1, Acts of Nature- Tornado or High Winds Condition, Revision 13 112-P\P-M16, Penetration Seals, Revision 7 2OST-33.35, Fire Rated Assemblies Visual Inspection, Revision 2 2OST-33.35A, Fire Rated Assemblies Visual lnspection, Revision 4 Other 2PFP-CB-712
NRC lN 2005-30, Safe Shutdown Potentially Challenged by Unanalyzed Internal Flooding Events and Inadequate Design

Section 1R11: Licensed Operator Requalification

Program Procedures
1OM-53A.1 .E-0(lSS1C), Reactor Trip or Safety Injection, Revision 1 1 1OM-53A.1 .E-1(lSS1
C), Loss of Reactor or Secondary Coolant, Revision 14 Condition Reports 201
1-00601 201
1-00607 Other White Team mini-drill scenario timeline, dated August 2011 Attachment Section 1 R12: Maintenance Effectiveness Other System 368, System Health Report 2no Quarter 2011 System 368, Maintenance Preventable Functional Failure Report, dated
8117111 Condition Reports 2011-01234
11-97251 1
1-97306 11-97311 1 1-98014

Section 1R13: Maintenance

Risk Assessment and Emergent Work Gontrol Procedures
2
ADM-2033, Risk Management Program, Revision 4 Work Orders
200471414 Condition Reports 1
1-98075 Other 11-97346 Beaver Valley Unit 't Weekly Maintenance Risk Summary dated
813111, Revision 1 Beaver Valley Unit 2 Weekly Maintenance Risk Summary for the week of September
19,2011, Revisions
0-2

Section 1Rl5: Operabilitv

Evaluations

Drawings

8700-RM-424-1, Revision 14
RM-0430-002, Revision 40 1 0080-RM-424-5, Revision 2 87 0O-02E18-0002, Revision B 8700-02040-0009, Revision B Procedures

1OM0 24.3.B.1, Valve List lFW, Revision 19 l

OST-1 .1 , Control Rod Assembly Partial Movement Test, Revision 16 1l2Ml-O1RC-Rod Control-1, Troubleshooting Guidelines for Rod Control, Revision 6
NOP-ER-3001-1, Problem Solving Plan, Revision 01
NOP-LP-2601, Procedure, Use and Adherence, Revision 3
NOP-WM-2003, Work Management Surveillance Process, Revision 5 1OST-24.4, Steam Turbine Driven Auxiliary Feed pump Test [1FW-P-2], Revision 46 Condition Reports 11-97892 11-96396 11-96222 05-01591 04-42790 01-83546 Other 11-00582 11-00272 11-97241
ECP 02-0183, Feedwater lsolation Valve Conceptual Design BVPS Ul Operator Logs, dated
816111 BVPS U2 operator logs, dated 8114111-8115111
Analysts, lnc,lJ2 2FWE-T22, Inboard Turbine Bearing Lubricating Oil Analysis, dated
312212011 Attachment
U1, Turbine Driven Auxiliary Feedpump [1FP-P-2]
Vibration Data.BVBP-SITE-0009, Pump Packing Guide, Revision 1 Work Order
200347907 NRC lN 2OO1-19, lmproper Maintenance and Reassembly of Automatic Oil Bubblers

Section 1R18: Plant Modifications

Condition Reports

1
1-97366 Procedures

lMSp+6S4A-E, 1DF 4KV Emergency Bus Diesel Start Undervoltage Relay 27-VF1O0 Calibration, Revision 9 Work Orders 2A0432269

200432147 200468374

Section 1R19: Post-Maintenance

Testinq Procedures

tZ nCF-SOA-PC, Calibration of Timing Relays, Revision 15 1/2

RCP-1A-PC, Calibration of Auxiliary Relays, Revision 8 lMSp-36.54A-E,1DF
4KV EmergencyBus Diesel Start Undervoltage Relay 27-VF10A Calibration, Revision 9 l
MSp-36-g2-E, Functional Test of 1DF 4KV Emergency Bus Loss of Voltage Relay \27-VFlAAl and Diesel start Loss of voltage Relay [27^VF1100], Revision I lMSp-36-S6-E, 1DF 4KV EmergencyBus Diesel Start Loss of Voltage Relay 27-VF11O0 Functional Test, Revision 20
BV-2BVT-O1.39.0g, Station Battery [BAT.2-4]
Performance Discharge Test, Revision 5
BV-2BW-Q1.39.04, Station Battery [BAT"2-4]
Service Test, Revision 7 2OST-39.1D, Weekly station Battery Check [BAT.2-4], Revision 18 2OST-39.5, Station Battery Check, Revision 5 Work Orders
200468374
200468727
200469469 Condition Reports 1
1-98138 1 1-981 39 1',l-97534
Other NOTF
600696456 g70o-RE-21CT,4kV
Emergency
1AE & 1DF Undervoltage, Revision 12 1008D-E-204.120V
Vital Bus Distribution Panel sizing, Revision 1

Section 1R22: Surveillance

Testinq Procedures

l 05T+62 Diesel Generator No' 2 Monthly Test, Revision 58 lOST-13.2, Quench Spray Pump [1OS-P-18]Test, Revision 37 11-98136 11-98162 11-98075 11-98014 Attachment

l

OST-24.3, Motor Driven Auxiliary Feed Pump Test [1FW-P-38], Revision 42 2OST-30.2, Service Water Pump [25SWS.P21A]Test, Revision 38 2OST-15.2.

etirury Component Cooling Water Pump !2CCP"P21BITest, Revision 50 2OST-1 .128, Safeguards Protection System Train B SIS Test, Revision 45 Condition Reports 11-97855 2011-00209

10-70270 11-94635 2011-00037
2011-A1114
2011-00438
2011-00446
Revision 5 Other u2 service water Pump Vibration Data,3113108

through

8128111 Procedures:
1/2ODC{1.01, ODCM: lndex, Matrix, and History of ODCM Changes, 1 l2-ODC-O2.01, Overall Environmental Monitoring Program, Revision 6 1 I 2-ODC-02.
03, ODCM : Rad iolog ical Environmental Monitoring Prog rams, Revision 2 1/2-ODC-03.02, ODCM: Bases for ODCM Controls, Revision 2 12-ADC-03.03, ODCM: Controls for RETS and REMP Program, Revision 5 1/2-ENV-02.01, Description of Overall Radiological Environmental Monitoring Program, Revision 8 1/2-ENV-03.01, Environmental Sampling, Revision 7 1/2-ENV-03.02, Maintenance

& Calibration of Automatic Water Sampling Equipment, Revision 3 1/2-ENV-03.03, Maintenance and Calibration of

AVS-28A Environmental Sampler, Revision 1 112-ENV-04.02, REMP Calculations, Revision 4 1
MSP-45.17-1, Meteorological Monitoring System Calibration, Revision 28 1
MSP-45.17A-1, Meteorological Monitoring System Calibration, Revision 28
BIBO-OP-2012, SystemMork Practice Prioritization for
NEI 07-07, Revision 0 1/2-ADM-1730, Laboratory Quality Assurance and lnstrument Quality Control Program, Revision 22 Samplinq Sites: Milk: Nos.25,96 Air Particulate/lodine:
Nos. 1 3, 27, 28, 29B,30, 32, 46'1, 47, 51 Drinking Water: Nos. 4, 5 Surface Water: Nos. 2.1, 5, 494 Thermo-luminescent Dosimeters:
Nos 10, 13, 14, 15, 27 , 28,29B,30, 32, 45, 45'1, 46, 46'1, 47 '51, 60,72 Nuclear Oversiqht (NO) RePorts: Fleet Oversight Audit Report (MS-C-10-08-02)
Fietd Observation Reporis Nos: BV32 01 1 4224, 8V3200937
95, 8V22O093821, 8V320093848, 8V320093883, 8V3201 03932, 8V3201 14154 Fleet Oversight First Trimester Report 2011 Condition Reports: 11-97516 11-97531 11-88282 11-88334 10-79472 10-80322 10-72229 10-80141 11-97518 11-97297 11-97739 11-92974 10-82309 10-86844 10-77489 10-78575 10-82309 10-86844 10-82742 10-71609 10-71609 10-81504 Attachment Calibration Records Air Sampler Nos. 6114,6115, 6116, 6117,6118, 6119, 6121,6122,6125,6127
Meteorological Primary & Redundant Instrumentation dated
711412011 Miscellaneous Reports: 2009 and 2010 Annual Effluent Release Reports/Annual Environmental Operating Reports 2010 Land Use Census and Evaluations for ODCM Controls 3'12.2 Environmental Cross Check Samples 4th Quarter 2010 and 1't Quarter 201 1 Interlaboratory Comparison Program Results - 1't Quarter 2011 Quarterly Rrei tlO Results for 2009, 2010, and through 1't quarter 2011 Monthly Radiological Effluent Occurrence Reports for April 2010 through June 2011 Monthly Exposure Control Effectiveness Reports for April 2010 through June 201 1 Section 4OM: ldentification and Resolution of Problems Condition Reports Tr-gzsgO 11-96151 11-97026 11-97126 11-90528 11-97123 11-92603 11^89144 11-89817 11-97899 11-97521 119A875 10-72649 10-73098 10-85569 11-92841 11-95161 11-97384 11-98009 2011-00393
2011-00394
2011-00395
2011-00396

Procedures

%-ADM-0100, Procedure Writer's Guide, Revision 8

NOP-OP-1002, Conduct of Operations, Revision 5
NOP-LP-2601, Procedure Use and Adherence, Revision 3
NOBP-OP-0004, Plant Status Control and Clearance Events, Revision 3
NOP-OP-1007, Risk Management, Revision 10%-ADM-2033, Risk Management Program, Revision 4%-ADM-0804, On-Line Risk Assessment and Management, Revision 9 Other Weekly Maintenance Risk Summary, Revision 0, dated
9112111 Top Ten Systems lmportant to Mitigating Core Damage for BVPS Unit 1 & 2

Section 4OA3: Event Response Condition

Reports zo*oogzg 2011-00980
2011-00981
2011-00983
2011-00986
2011-00988
2011-00989
2011-00990
2011-00991
2011^00992
2011-00993
2011-00994
2011-OOgg5
2011-00996
2011-00997
2011-00998
2011-00999
2011-01002
2011-O1OO4
2011-01Q04
2011-01006
2011-01010
2011-01018
ADM BCO BVPS CAP CFR CR FA FENOC IMC toD IP lst LCO LER MR MSP NEI NRC OD ODCM OST PI PI&R POD PMT REMP SSC SWS TLD TS UFSAR A-8

LIST OF ACRONYMS

Adm in istrative

Proced ure Basis for Continued

Operations

Beaver Valley Power Station Corrective

Action Program Code of Federal Regulations

Condition

Report(s)Functional

ity Assessments

First Energy Nuclear Operating

Company Inspection

Manual Chapter lmmediate

Operability

Determination

Inspection

Procedure Inservice

lnspection

Limiting Conditions

for Operations

Licensee Event Report Maintenance

Rule Maintenance

Surveillance

Package Nuclear Energy Institute Nuclear Regulatory

Comm ission Operability

Determinations

Off-Site Dose Calculation

Manual Operations

Surveillance

Test Performance

Indicator Problem ldentification

and Resolution

Prompt Operability

Determination

Post Maintenance

Testing Rad iolog ical Environ mental Mon itoring Prog ram Structures, Systems, and Components

Service Water System Thermo-Luminescent

Dosimeter Technical

Specification

Updated Final Safety Analysis Report Attachment