IR 05000322/1978014 | 10 October 1978 | IE Inspec Rept 50-322/78-14 on 780913-15 During Which No Items of Noncompliance Were Noted.Major Areas Inspected Incl:Admin Controls,Sched for Completion of Sys & Tests, Status of Procedure Completion & Facil Inspec | |
IR 05000322/1982009 | 16 July 1982 | IE Safeguards Insp Rept 50-322/82-09 on 820425-29.No Noncompliance Noted.Major Areas Inspected:Physical Security Plan,Security Organization,Records & Repts,Testing & Maint, Locks,Keys & Combination.Details Withheld (Ref 10CFR73.21) | |
IR 05000322/1982010 | 21 May 1982 | IE Insp Rept 50-322/82-10 on 820426-29.Noncompliance Noted: Flow Measuring & Test Equipment Panel 42-4,used for Local Leak Rate Testing of Primary Containment Isolation Valve MOV-031C,not Properly Calibr | Shutdown Margin Scram Discharge Volume Pressure boundary leak |
IR 05000322/1982012 | 27 May 1982 | IE Insp Rept 50-322/82-12 on 820518-21.No Noncompliance Noted.Major Areas Inspected:Licensee Work & QC Activities Re Corrective Action for Significant Deficiencies & Other Outstanding Items | Fire Barrier |
IR 05000322/1984016 | 18 May 1984 | IE Insp Rept 50-322/84-16 on 840416-20,30 & 0501-04.No Violations Noted.Major Areas Inspected:Preoperational Test Program,Test Witnessing of Integrated Electrical Test & Tours | |
IR 05000322/1984046 | 19 December 1984 | Insp Rept 50-322/84-46 on 841203-07.Deviation Noted:Fire Doors Degraded Due to Security Mods,Structural Steel Fireproofing Damaged in Charcoal Filter & Chiller Room & Lack of Emergency Lighting in Specific Locations | Safe Shutdown Fire Barrier Emergency Lighting Fire Protection Program |
IR 05000322/1985006 | 29 May 1985 | Insp Rept 50-322/85-06 on 850122-25.No Violations Noted. Major Areas Inspected:Open Items from Previous Insp & Status of Programs for Changes to Emergency Preparedness Program, Performance of Duty & Licensee Audits | Health Physics Network |
IR 05000322/1985016 | 1 July 1985 | Physical Security Insp Rept 50-322/85-16 on 850304-08.No Violation Noted.Major Areas Inspected:Training of Security Force Personnel,Including Qualification Tasks Exam Administration & Reviews of Exam Results | |
IR 05000322/1985018 | 4 April 1985 | Insp Rept 50-322/85-18 on 850301-31.No Violation Noted.Major Areas Inspected:Procedures for Racking Out 4 Kv Bus 11 Circuit Breakers,Crd Orifice Cleaning Efforts & Tdi Diesel Starting Air Check Valves | Hydrostatic Fire Protection Program Fire Watch |
IR 05000322/1985020 | 23 May 1985 | Insp Rept 50-322/85-20 on 850401-0515.No Violation Noted. Major Areas Inspected:Evaluation of Wetwell/Drywell Inerting Nitrogen Cooling Components,Colt Diesel Generator Testing Status & Previous Insp Items | |
IR 05000322/1985021 | 12 August 1985 | Insp Rept 50-322/85-21 on 850409-0510.No Violation Noted. Major Areas Inspected:Allegations Re Design,Insp & Testing of Plant | Stroke time Earthquake Liquid penetrant Siren |
IR 05000322/1985022 | 2 August 1985 | Insp Rept 50-322/85-22 on 850410-0510 of Allegations Re Design,Insp & Testing.Two Allegations Re Calibr of nonsafety-related Extraction Steam Pressure Switch & Laundry Drain Tank Level Alarm Substantiated | Loop seal Pressure Boundary Leakage |
IR 05000322/1985023 | 29 May 1985 | Insp Rept 50-322/85-23 on 850429-0501.No Violation or Deviation Noted.Major Areas Inspected:Emergency Lighting & Safe Shutdown Capability of Plant in Event of Fire & Followup of Previous Insp | Safe Shutdown Emergency Lighting |
IR 05000322/1985024 | 8 July 1985 | Insp Rept 50-322/85-24 on 850516-0618.No Violation Noted. Major Areas Inspected:Isolation of RCS Pressure from Low Pressure Re ECCS Sys Outside Containment & Disablement of 4,160-volt Emergency Bus auto-transfer Capability | Reserve Station Service Transformer |
IR 05000322/1985025 | 2 October 1985 | Physical Security Insp Rept 50-322/85-25 on 850611-14.No Noncompliance Noted.Major Areas Inspected:Onsite Review of Rev 10 Proposed Changes to Physical Security Plan & Personnel Training & Qualification | |
IR 05000322/1985026 | 29 July 1985 | Insp Rept 50-322/85-26 on 850612-14.No Violation Noted.Major Areas Inspected:Licensee Action on Outstanding Items, Radiological Controls Organization,Staffing & Training,Ie Bulletin 80-10 & Startup Testing | Safe Shutdown |
IR 05000322/1985027 | 23 August 1985 | Insp Rept 50-322/85-27 on 850628-0802.No Violations Noted. Major Areas Inspected:Startup & Testing Conducted After Issuance of 5% License & Licensee Action on Opening of Primary Containment Purge Valves on 850710 | Reactor Vessel Water Level Temporary Modification |
IR 05000322/1985028 | 2 August 1985 | Insp Rept 50-322/85-28 on 850624-28.No Violations Noted. Major Areas Inspected:Startup Test Program,Including Startup Test Results,Test Exception Repts,Core Thermal Power Determination & Qa/Qc Interfaces | Shutdown Margin Scaffolding |
IR 05000322/1985029 | 27 August 1985 | Insp Rept 50-322/85-29 on 850706-26.No Violations Noted. Major Areas Inspected:Startup Test Program,Including Startup Test Witnessing & Startup Test Results Evaluation & Licensee Action on Previous Insp Findings | |
IR 05000322/1985030 | 20 September 1985 | Insp Rept 50-322/85-30 on 850803-31.No Violations Noted. Major Areas Inspected:Operations Conducted Under Power Ascension Test Program & Status of Previous Open Items.Four Items Closed & Two New Items Opened | Time of Discovery Reactor Vessel Water Level Ultimate heat sink |
IR 05000322/1985031 | 18 September 1985 | Insp Rept 50-322/85-31 on 850729-0812.Violation Noted: Failure of Test Personnel to Implement Governing Startup Test Procedures for Activities Affecting Quality | Packing leak Stroke time Test box |
IR 05000322/1985032 | 4 October 1985 | Insp Rept 50-322/85-32 on 850812-30.No Violations Noted. Major Areas Inspected:Startup Test Program During Test Condition Heatup,Including Startup Test Witnessing,Results Evaluation,Procedure Review & Technical Review Committee | Stroke time |
IR 05000322/1985033 | 24 December 1985 | Physical Security Insp Rept 50-322/85-33 on 850826-30.No Violation Noted.Major Areas Inspected:Vital Areas,Security Sys Power Supply & Safeguards Contingency Plan.Portions Deleted (Ref 10CFR73.21 & 2.790) | Safeguards Contingency Plan |
IR 05000322/1985034 | 29 January 1986 | Exam Rept 50-322/85-34 on 850916-20.Exam Results:All Candidates Passed Both Written & Oral Exams | |
IR 05000322/1985035 | 2 October 1985 | Insp Rept 50-322/85-35 on 850830-0913.No Violations Noted. Major Areas Inspected:Startup Test Program Activities & Licensee Investigation of Reactor Water Level Indication Problems & Unplanned Reactor Scrams | Reactor Vessel Water Level Scaffolding |
IR 05000322/1985036 | 25 October 1985 | Insp Rept 50-322/85-36 on 850901-30.No Violations Noted. Major Areas Inspected:Power Ascension Test Program,Including Startup,Shutdown & Sys Testing.Two New Items Opened | Fitness for Duty High winds Hydrostatic |
IR 05000322/1985037 | 5 November 1985 | Insp Rept 50-322/85-37 on 850916-1008.No Violation Noted. Major Areas Inspected:Startup Test Program During Test Condition Heatup,Main Turbine Initial Operation & Valve Operator Failures | Stroke time Coast down |
IR 05000322/1985038 | 20 November 1985 | Insp Rept 50-322/85-38 on 851021-25.No Violation Noted.Major Areas Inspected:Radiological Controls,Including Startup Survey Program,Preoperational & Startup Testing of Offgas Sys & High Radiation Area Controls | High Radiation Area |
IR 05000322/1985039 | 14 November 1985 | Insp Rept 50-322/85-39 on 851001-31.No Unacceptable Conditions Noted.Major Areas Inspected:Part 21 Diesel Generator Notification from American Air Filter Re Tdi Diesels & 5% Power Ascension Test Program | Fitness for Duty |
IR 05000322/1985040 | 29 November 1985 | Insp Rept 50-322/85-40 on 851015-18.No Violations Noted. Major Areas Inspected:Nonradiological Chemistry Program, Including Measurement Control & Analytical Procedure Evaluations | |
IR 05000322/1985042 | 31 December 1985 | Insp Rept 50-322/85-42 on 851101-30.Violations Noted: Inadequate Procedural Controls & Failure to Adhere to Approved Procedures Re Maint Work on RHR Pump B Suppression Pool Suction Valve | Scaffolding |
IR 05000322/1985043 | 31 January 1986 | Insp Rept 50-322/85-43 on 851201-31.No Violations or Deviations Noted.Major Areas Inspected:Completion of Neutron Source Outage & Transition Prior to Reactor Water Level Ref Leg Replacement Outage | Half scram Anchor Darling |
IR 05000322/1985099 | 24 May 1985 | SALP Rept 50-322/85-99 for Mar 1984 - Feb 1985.Weaknesses Noted W/Control of Plant Evolutions & Timely Resolution of QC Deficiencies.Effective Mgt Involvement & Control of Most Plant Activities Noted | Safe Shutdown Shutdown Margin Emergency Lighting Process Control Program Systematic Assessment of Licensee Performance License Renewal Control of Heavy Loads Fire Protection Program Fire Watch |
IR 05000322/1986001 | 7 March 1986 | Insp Rept 50-322/86-01 on 860101-31.No Unacceptable Conditions Noted.Major Areas Inspected:Reactor Water Level Ref Leg Replacement Outage.Five Open Items Closed | Probabilistic Risk Assessment |
IR 05000322/1986002 | 31 March 1986 | Emergency Preparedness Insp Rept 50-322/86-02 on 860212-14. No Violation Noted.Major Areas Inspected:Observation of Onsite Portion of First full-scale Emergency Exercise on 860213 | |
IR 05000322/1986003 | 23 April 1986 | Enforcement Conference Rept 50-322/86-03 on 860320.Areas Discussed:Lack of Mgt Awareness of Programmatic Breakdown in Radiochemistry Area,Qa Audit Rept 85-05 & Training Dept Coordination | |
IR 05000322/1986004 | 13 March 1986 | Physical Security Insp Rept 50-322/86-04 on 860210-14.No Violations or Deviations Noted.Major Areas Inspected: Organization Audits,Records & Repts,Testing & Maint & Locks & Keys.Details Deleted (Ref 10CFR73.21 & 2.790) | |
IR 05000322/1986005 | 26 March 1986 | Insp Rept 50-322/86-05 on 860201-28.No Unacceptable Conditions Noted.Major Areas Inspected:Observations of Activities,Interviews W/Personnel & Document Reviews | Probabilistic Risk Assessment Squib |
IR 05000322/1986006 | 26 March 1986 | Insp Rept 50-322/86-06 on 860225-28.No Violations Identified.Major Areas Inspected:Transportation Activities, Including Audits,Training,Procedures,Shipments of Radioactive Matl,Package Selection,Mgt Control & QA | Process Control Program |
IR 05000322/1986007 | 2 June 1986 | Insp Rept 50-322/86-07 on 860505-09.No Violations Noted. Major Areas Inspected:Organization & Staffing,Qa Audits, Internal & External Exposure Control & Status of Previously Identified Items | High Radiation Area |
IR 05000322/1986008 | 21 May 1986 | Insp Rept 50-322/86-08 on 860301-0415.Violation Noted:Work Performed on EDG103 Under Maint Work Request 86-0746 Completed W/O Evidence of Written Procedures or Job Plan to Describe Work Procedure | Ultimate heat sink Continuous fire watch Fire Watch |
IR 05000322/1986009 | 11 April 1986 | Insp Rept 50-322/86-09 on 860324-27.No Violation Noted.Major Areas Inspected:Actions on Previous Insp Findings & Startup Test Program,Including Overall Program,Test Plateau Review, Test Results Evaluation & Tour of Facility | |
IR 05000322/1986011 | 4 September 1986 | Safety Insp Rept 50-322/86-11 on 860728-0801.No Violation or Deviation Noted.Major Areas Inspected:Chemistry Mgt & Organization,Radioactive Capability Test Samples,Effluent Release Records & Repts & Effluent Sampling & Analysis | Grab sample Offsite Dose Calculation Manual |
IR 05000322/1986012 | 29 July 1986 | Insp Rept 50-322/86-12 on 860601-0715.No Unacceptable Conditions Noted.Major Areas Inspected:Conduct of Surveillance & Maint Activities & Other Routine Resident Inspector Activities | High Radiation Area Grab sample |
IR 05000322/1986013 | 13 August 1986 | Insp Rept 50-322/86-13 on 860630-0702.Potential Violation Noted:Unidentifiable,Unqualified Wiring in Limitorque Motor Operator Valve Internal Wiring | |
IR 05000322/1986014 | 7 October 1986 | Insp Rept 50-322/86-14 on 860716-0831.No Unacceptable Conditions Noted.Open Items Noted:Safety Sys Actuations from Electrical Assembly Breaker Spurious Trips & 10CFR21 Rept Re Escape Airlock | Half scram Ultimate heat sink Squib Emergency Lighting Systematic Assessment of Licensee Performance Moisture barrier |
IR 05000322/1986015 | 15 September 1986 | Insp Rept 50-322/86-15 on 860825-29.No Violation Noted.Major Areas Inspected:Radiation Work Permits,Routine Radiation Surveys & QC Surveillance of Radiation Protection Activities | |
IR 05000322/1986016 | 19 December 1986 | Insp Rept 50-322/86-16 on 860901-1115.No Violation Noted. Major Areas Inspected:Surveillance & Maint Activities Re Mod Performed on HPCI Sys & Work on Colt Diesel Generator Tie in | Hydrostatic Scram Discharge Volume Continuous fire watch |
IR 05000322/1986017 | 22 October 1986 | Insp Rept 50-322/86-17 on 860908-12.No Violations or Deviations Noted.Major Areas Inspected:Nonlicensed Staff Training | Liquid penetrant |
IR 05000322/1986018 | 24 October 1986 | Insp Rept 50-322/86-18 on 860929-1003.No Violations Noted. Major Areas Inspected:Startup Test Program,Test Results Evaluation,Test Procedures Review,Independent Measurements, Qa/Qc Interfaces & Tours of Facility |