U.S. NUCLEAR REGULATORY COMMISSION

REGION I

'

Report No. ~ 50-322/85-33 Docket No.

50-322 License No. NPF-19 Safeguards Group IV Licensee:

Long Island Lighting Company 175 East Old Country Road Hicksville, New York 11801 Facility Name: Shoreham Nuclear Power Station Inspection At: Wading River, New York Inspection Conducted: August 26-30, 1985 Date of Last Physical Security Inspection:

June 11-14, 1985 Type of Inspection:

Routine, Unannounced Physical Security Inspector:

-

/ 1, 2,

[

W. G. Mart'in, Physicalycurity Inspector date Approved by:

[

/ 2.

y

R. R. Keimid, Chief,,jrTeguards Section,

'date

~

DRSS V

Inspection Summary:

Routine, Unannounced Physical Security Inspection on August 26-30, 1985 (Inspection Report No. 50-322/85-33)

Areas Inspected:

Routine inspection for Physical Barriers - Protected Area;

= Physical Barriers-Vital Areas; Security System Power Supply; Lighting; Safe-guards Contingency Plan Implementation Review; and a follow up on previously identified inspector concerns.

The inspection involved 34 hours3.935185e-4 days <br />0.00944 hours <br />5.621693e-5 weeks <br />1.2937e-5 months <br /> onsite by one region-based inspector.

Results: The licensee was found to be in compliance with NRC requirements in the areas inspected.

.

O

'

..

DETAILS 1.

Key Persons Contacted-J. Smith, Manager, Nuclear Operations Support Department J. Morin, Manager, Nuclear Services Division R. Reen, Site Security Supervisor J. Devlin, Security Administrative Supervisor K. King, Security _ Engineer R. Fisher, YOH, Security Program Manager R. Cobb, Y0H, Security Performance Analyst 2.

MC 30703 - Exit Interview At the conclusion of the inspection on August 30, 1985,.the inspector met with the licensee representatives listed in Paragraph 1.

At that time, the purpose, scope and results of the inspection were reviewed.

At no time during the inspection was written material provided to the licensee by the inspector.

3.

MC 92701 - Status of Inspector' Follow-up Items (Closed)InspectorFollow-upItem(50-322f82-09-04)

a.

11:15 P!R/M APF.' CO.4It.!!!S SUBUfim INF0?.MATUU 15 !3 !!91 ITG. N711C DSCLOSU"1,li15 ME!:1!DiU.Ll?

LEFT R TJ;'s.

b.

(Closed)InspectorFollow-upItem(50-322/84-31-01)

~

All issues (26) that were identified by this item as needing imple-mentation or correction have been completed to the satisfaction of the inspector, c.

(Closed) Inspector Follow-up Item (50-322/84-48-01)

The licensee has taken action to prevent recurrence of improper guard posting, inoperable radios, and improper radio checks as outlined in its letter of April 20, 1985 to NRC Region I.

A new procedure SP 91.010.01 " Security Post Orders" was approved on April 9,1985.

d..

(Closed) Inspector Follow-up Item (50-322/85-05-01)

The inspector determined that the licensee has taken action to simplify to accountability of lock set *

.

!

e.:

(C'osed)InspectorFollow-upItem(50-322/85-05-02)

The inspector determined that the licensee provided supplemental training for and increased supervisory surveillance over the vehicle search process. The inspector observed vehicle searches periodically during the inspection and did not observe any deviations from approved procedures.

f.

(Closed)

Inspector Follow-up Item (50-322/85-16-01)

A new examination was developed for CAS/SAS operators and was admin-istered.

Each operator was requalified. The test results were furnished to the NRC by letter dated July 16, 1985.

4.

MC 81052 - Physical Barriers-Protected Area THIS PARAGRAPil CONT AltlS SAFEGUMUS INFO'1MATiON AND 15 !!01 FOR PUBilC DISCLOSURE,IT IS lHTENTIDHALLY LEFT BLANK.

'5.

MC 81054 - Physical Barriers - Vital Areas THIS PARACHAPli C0!!TAINS SAFEGU ARDS inFclMtsitan A!!D 15 !!01 FOR Pi!BilC DISCLOSilRE,liIS INTENTIONALLY LEFT BLANK.

6.

MC 81058 - Security Systera Power Supply The inspector determined by review that the licensee's emergency back-up power for the site security system; conforras to the NRC physical security plan and its implementing procedures.

7.

MC 81062 - Lighting The inspector confirmed by observation that the licensee's lighting in isolation zones and in the protected area met the commitments contained in the physical security plan and was appropriate for its intended functio... __

. - _.

.

.

.

,

..

,

The lighting was sufficient to monitor and observe persons and activities within the isolation zones and the protected area with closed. circuit television or direct visual surveillance.

8.

MC 81601 Safeguards Contingency Plan Implementation Review The licensee's program for responding to security threats and other contingencies, as outlined in the approved Security Contingency Plan, was reviewed by the inspector. The licensee has conducted one drill, which is

~

documented to exercise the plan. _The licensee informed the' inspector that drills will be conducted on a frequency of once per quarter.

.

t L _