1992 Ginna Station Plume Exposure Emergency Preparedness Exercise 921008, Final Rev
ML17309A499
Person / Time
Site: Ginna Constellation icon.png
Issue date: 10/08/1992
From: BACKUS W H, POLFLEIT P S, WATTS R J
ROCHESTER GAS & ELECTRIC CORP.
To:
References
NUDOCS 9210300061
Download: ML17309A499 (487)


Text

FORD2riREGULATINFORMATION DISTRIBUTION STEM(RIDS)ACCESSION NBR:9210300061 DOC.DATE:

92/10/08NOTARIZED:

NODOCKETFAClL:50-244 RobertEmmetGinnaNuclearPlant,Unit1,Rochester G05000244AUTH.NAMEAUTHORAFFILIATION POLFLEIT,P.S.

Rochester Gas6ElectricCorp.BACKUS,W.H.

Rochester Gas&ElectricCorp.WATTS,R.J.

Rochester Gas6ElectricCorp.RECIP.NAME RECIPIENT AFFILIATION NOTES:License Expdateinaccordance with10CFR2,2.109(9/19/72).

568/peRECIPIENT COPIESIDCODE/NAME LTTRENCLCOPIESLTTRENCLRECIPIENT IDCODE/NAME

SUBJECT:

"Rochester GasaElectricCorpGinnaStation1992PlumeExposureEmergency Preparedness Exercise921008."DISTRIBUTION CODE:DF01DCOPIESRECEIVED:LTR ENCLSIZE:TITLE:DirectFlowDistribution:

50Docket(PDRAvail)S/05000244F-RINTERNAL:

NUDOCS-ABSTRACT EXTERNAL:

NRCPDRiC~c'dLt%q'g,REGFILE01NSICYOTETOALL"RIDS"RECIPIENTS:

PLEASEHELPUSTOREDUCEWASTE!CONTACTTHEDOCUMENTCONTROLDESK.ROOMPl-37(EXT.504-2065)

TOELIMINATE YOURNAMEFROMDISTRIBUTION LISTSFORDOCUMENTS YOUDON'TYEED!TOTALNUMBEROFCOPIESREQUIRED:

LTTR4ENCL4 ACaIIf

~~ROCHESTER CPSPHDELECTRICtISS2QljlMIMA, SVAVIjOolM PlLUKSKKXPOoSUHKXKIRCIIM OoCVOo55lg 5psstfsI~ilijI1sst)lvsIIliltll~~~~~ssssassgig<1ssss~st~~~~~s's~~~~c.,'BUŽV4J's2103000b1 921008PDRADOCK05000244 THEROCHESTER GASANDELECTRIC-CORPORATION GINNASTATIONEIVIERGENCY PREPAREDNESS EXERCISEMANUALI1I1992PLUIVIEEXPOSUREEMERGENCY PREPAREDNESS EjKERCISE

'/(FINALREVISION)

October8,1992PreparedBy:iCpspgpQp~leterSPolfleitesleyH.BackusReviewedBy:"".~/P.Q/6.,r.,

<<.~gyT.ji>4"C~/<i)'-.RichardJ.WattsApprovedBy:RidJ.Beldue~g'(Emergency PlanningMilestone Committee)

.4'ONTROL~LED COPYII10:C92i03000hi 921008PDRADOCK05000244PDR

)fVH11k ROCHESTER GASANDELECTRICCORPORATION GINNASTATION1992PLUIVIEEXPOSUREEIVIERGENCY PREPAREDNESS EXERCISEFOREWORDThisExercisepackagehasbeendeveloped toprovidethebasisfortheconductofasimulated radiological accidentattheGinnaStationlocatedinOntario,NewYork.ThroughthisExercise, thecapabilities andeffectiveness oftheEmergency ResponsePlansfortheRochester GasandElectricCorporation, theStateofNewYork,andMonroeandWayneCountieswillbeevaluated.

ThispackageistobeutilizedbytheExerciseControllers andobservers toinitiate, controlandevaluatetheactivities oftheparticipants intheExercise.

TheRochester GasandElectricCorporation approvesthisdocumentasthestandardforconductinperformance oftheOctober,1992Emergency Preparedness Exercise.

AO>TAT"Ai".4*38'DRUBSc~AGQ'c:~~3

'j-)3i,.".~ii:<

I"RQ')'I<"lC"JULiQd"Cs'G&tli~)Lit a~ail4~~fi4gt)fQWQAIO~JhAl,Gc,

<<<>39"c'..".".

~Cy,f,>i]~'QPa8"SG'3C"'h 18"I;,'.:)i" f>>;<'fAisPB."JD~'3".>,

A~~i"f';i..'xi.

Y~'fd>a"lf1~i<~'"-IIM'ROVEiOl'1bJA' h;;c,lo>roc"..-'..~-,"-

-.'.,!;.,",>>.

~CJitill'4'>~",9<"Bl.'iOUP<<PbkBP>~C>>f.-('-~>3~rs,iJ-~i-,l<<'.;.~-)SliJ'0'v'l&l'4'i'"'

a>rlii,~'4-<,q~s4~M~Lw~4>ilI~'!VIILLh'IIJ~a,I~n THEROCHESTER GASANDELECTRICCORPORATION, GINNASTATION1992PLUMEEXPOSUREEMERGENCY PREPAREDNESS EXERCISEINTRODUCTION TheNuclearEmergency ResponsePlan(NERP)describes theemergency responsecapabilities foranuclearemergency attheGinnaStation,including supportfromFederal,State,andlocalgovernment agenciesandprivateorganizations.

TheNuclearEmergency ResponsePlanprovidesforcontinuous emergency preparedness, including anannualExercise.

ThepurposeofthePlumeExposureEmergency Preparedness Exerciseistoactivateandevaluatemajorportionsoftheemergency responsecapabilities andotheraspectsoftheEmergency Planandassociated Emergency PlanImplementing Procedures, inaccordance withNuclearRegulatory Commission (NRC)Regulation 10CFR50.47(b) andAppendixE.ThisExercisewillbewiththeparticipation oftheStateofNewYork,andtheCountiesofWayneandMonroeinordertoassessStateandLocalGovernment AgencyEmergency Response.

Theconductandevaluation oftheExerciseprovideadditional trainingforthePlumeExposurePathwayemergency responseorganization personnel andameanstofurtherenhanceRochester GasandElectricCorporation's emergency responsecapability.

ThisExerciseManualhasbeendeveloped toprovidethebasisfortheconductofasimulated radiological accidentattheGinnaStationfacilitylocatedinOntario,New,York.ThismanualistobeutilizedbytheExerciseControllers toinitiate, control,andevaluatetheactivities oftheparticipants intheExercise.

Exercise"Iers"willnhaveriorknowledeofthenareofheimlaedinidenoranrhereofsuchasrdiploicallumereleaseinformaionincludintimescontensizeandweatherarnused.ThisExerciseManualisthecontrolmechanism fortheconductoftheExerciseandconsistsoftwoparts.PartIprovidesageneraldescription andoverviewoftheemergency Exercise.

PartIIcontainsthescenarioandtimescheduleofsimulated plantconditions.

TheExerciseManualissubjecttoalimited,controlled distribution.

1992PLUMEEXPOSUREEMERGENCY PREPAREDNESS EXERCISECENARIO"DEVELOPMENT COIVIIVIITTEE "WesBackusRichardBeldueRichardBiedenbach WilliamDillonDanHudnutJamesKnorrFrankOrienterPeterPolfleitFrankPudduJamesReganRichardWattsTerryWhiteJamesZulawskiDennisBehr(EEM)"Asauthorized bytheEmergency PlanningMilestone Committee 9flOfi',5c!LO().

GINNASTATION1992PLUMEEXPOSUREEMERGENCY PREPAREDNESS EXERCISETABLEOFCONTENTSFOREWORDINTRODUCTION SCENARIODEVELOPMENT COMMITTEE TABLEOFCONTENTSLISTOFFIGURES1.0SCOPEANDOBJECTIVES 1.11.21.31.4ScopeOnsiteObjectives SummaryofProposedActivities OffsiteProposedActivities

2.0 EXERCISEINFORIVIATION

2.12.22.32.42.52.6ExerciseParticipants ExerciseOrganization Emergency ResponseFacilities Exercise'ConductPrecautions andLimitations Evaluation andCritique3.0TRAVELINFORMATION 3.1Directions toGinnaStation3.2Directions toEOF,ESCandJENC3.3Accommodations

4.0REFERENCES

ABBREVIATIONS-ACRONYIVIS 4.1References 4.2Abbreviations-Acronyms

5.0 CONTROLLER

ANDEVALUATOR INFORMATION 5.15.25.35.45,5Controller Instructions Evaluation In'structions Personnel Assignments Evaluation PackagesPublicInformation, RumorControl5SpouseQuestions Phone6.0SCHEDULEOFEVENTS GINNASTATION1992PLUMEEXPOSUREEIVIERGENCY PREPAREDNESS EXERCISETABLEOFCONTENTS(Cont'd)7.0EXERCISESCENARIO7.17.27.37.4InitialConditions OnsiteSequenceofEventsSimulator SetUpInstructions Simulator UseGuidelines 8.0MESSAGEFORIVISANDPLANTDATASHEETS9.0ON-SITERADIOLOGICAL ANDCHEIVlISTRY DATA9.1Radiological Summary9.2In-PlantRadiation Data9.3Post-Accident SamplingResults10.0METEOROLOGICAL ANDOFF-SITERADIOLOGICAL DATA10.1Meteorological Data10.2FieldDataandMaps10.3FieldAirIsotopicData GINNASTATION'1992PLUMEEXPOSUREEMERGENCY PREPAREDNESS EXERCISETABLEOFCONTENTS(Cont'd)LISTOFFIGURESSECTION3.0Figure3.1Figure3.2Figure3.3Figure3.4Figure3.5Directions toGinnaStationMapofRochester andVicinityMapofRochester CentralBusinessDistrictDirections toStateEmergency Operations Center,AlbanyMapofStateOfficeBuildingCampus,AlbanySECTION9.0Figure9,1Figure9.2Figure9.3AssumedSourceTermAirEjectorConcentrations VsTimeRCSConcentrations VsTimeSECTION10.0Figure10.1Direction ofPlumeFigure10.2PlumeMap(0-1Mile)Figure10.3LargePlumeMap(0-10Mile)

'

GINNASTATION1992PLUMEEXPOSUREEMERGENCY PREPAREDNESS EXERCISETABLEOFCONTENTS(Cont'd)LISTOFTABLESSECTION1.0Table1~1ProposedOnsiteActivities SECTION5.0Table5.1RG&EOnsiteController Organization SECTION7.0Table7.1Simulator Set-upDataforExerciseScenarioTable7.2Simulator Set-upData(RadMonitorReadings)

Table7.3Simulator UseGuidelines SECTION9.0Table9.1Table9.2Table9.3Table9.4Table9~5Table9.6Table9.7AssumedReleaseQuantities Equilibrium ReactorCoolantActivityPost-Accident ReactorCoolantSamples(Gas)Post-Accident ReactorCoolantSamples(De-Gassed)

Boron,pHContinuous AirMonitorReadings(Auxiliary Bldg)AirSampleResultsinTSCandControlRoomSECTION10.0Table10.1Table10.2Table10.3Table10.4Table10.5Table10.6Table10.7ForecastInformation PlumeArrival/Departure TimesRadiological Survey/Sampling Data(InPlume)Radiological Survey/Sampling Data(InPlume)Post-Plume GroundSurveyData(cpm)Post-Plume Micro-R/hr DataAirSampleIsotopicAnalysisData SECTION1.0SCOPEANDOBJECTIVES COPEANDNSITEOBJETIVES-PLUMEEXPOSREPATHWAY$co~eThe1992Emergency Preparedness PlumeExposuiePathwayExercisewillsimulateaccidenteventsculminating inaradiological accidentresulting intheactivation ofonsiteandoffsitefacilities.

TheExercisewillinvolveeventsthattesttheeffectiveness oftheGinnaStationEmergency Preparedness Programandtheintegrated capabilities ofcertainelementsoftheStateofNewYork,WayneCountyandMonroeCountyemergency organizations.

TheExercisewillincludethepartialmobilization ofstateandlocalresources toadequately verifytheircapability torespondtoanaccidentattheGinnaNuclearPowerPlant.OnsiteObecivesforthe192GinnaEvaluated PlumeExosurePathwaExerciseThemajorobjective oftheExerciseistodemonstrate theresponsecapabilities oftheRochester GasandElectricCorporation Emergency Organization.

Withinthisoverallobjective, numerousindividual objectives arespecified asfollows;Demonstrate theabilitytomobilize, staffandactivateEmergency ResponseFacilities promptly.

Demonstrate theabilitytofullystafffacilities andtomaintainstaffingonanaround-the-clock basisthroughtheuseofreliefshiftrosters(limitedshiftchangesmayoccurtoallowforoperational restrictions).

Demonstrate theabilitytomakedecisions andtocoordinate emergency activities.

Demonstrate theadequacyoffacilities anddisplaysandtheutilization ofprocedures tosupportemergency operations.

Demonstrate theabilitytocommunicate withallappropriate locations, organizations, andfieldpersonnel.

Demonstrate theabilitytomobilizeanddeployRadiation SurveyTeams..Demonstrate theappropriate equipment andprocedures for,thedetermination ofambientradiation levels.1-1 Demonstrate theproperuseofappropriate equipment andprocedures formeasurement ofairborneradioiodine concentrations aslowas1.0E-7uCi/ccinthepresenceofnoblegases.Demonstrate theabilitytoprojectdosagetothepublicviaplumeexposure, basedonPlantandfielddata,andtodetermine appropriate protective

measures, basedonplantconditions, Protective ActionGuidelines, available shelter,evacuation timeestimates, expectedreleaseduration, andotherappropriate factors.Demonstrate theabilitytonotifyoffsiteofficials andagencieswithin15minutesofdeclaration ofanemergency.

Demonstrate theabilitytoperiodically updateoffsiteofficials andagenciesofthestatusoftheemergency basedondataavailable atGinnaStation.Demonstrate theabilitytonotifyemergency supportpoolsasappropriate (i.e.,INPO,ANI,etc.).Demonstrate theabilitytonotifyonsitepersonnel usingplantalarmsandpublicaddresssystems.Demonstrate theorganization's abilitytoassessplantparameters andsymptomsindicative ofdegrading plantconditions, andrelatesuchsymptomstoprescribed Emergency ActionLevels.Demonstrate theorganization's abilitytoproperlyclassifyemergency conditions.

Demonstrate theorganizational abilityandresources necessary tomanageanaccountability ofpersonnel withintherestricted area.Demonstrate theorganizational abilityandresources necessary tocontrolaccesstothesite.Demonstrate theabilitytocontinuously monitorandcontrolemergency workers'xposure.

Demonstrate theadequacyoffacilities anddisplaystosupporttheJointEmergency NewsCenteroperations.

1-2 Demonstrate theabilitytobriefthemediainaclear,accurate, andtimelymanner.Demonstrate theabilitytoprovideadvancedcoordination ofinformation releasedtothepublic.Demonstrate theabilitytoestablish andoperaterumorcontrolinacoordinated fashion,Demonstrate theadequacyofin-plantpost-accident samplingtechniques andanalysis.

Demonstrate theabilitytodeveloppreliminary short-term andlong-termactionstosupportplantrecovery.

Demonstrate theproperuseofback-upcommunications intheeventofselectedcommunications equipment malfunction.

Demonstrate theabilitytomobilizeprincipal portionsofthelicenseeemergency organization onanoff-hours, unannounced basis.~ToberformedsamuserindrilldurinNovember1992.Demonstrate theabilitytoconductapost-exercise critiquewhichadequately characterizes licenseeperformance baseduponcontroller andobserverassessments.

SummarofProosedAcivitiesTable1.1providesalistofproposedRGREactivities.

1-3

TABLE1.11992GINNASTATIONEIVIERGENCY PREPAREDNESS EXERCISEPLUIVIEEXPOSUREPROPOSEDONSITEACTIVITIES RGLENotification ofAgenciesCallUpofPersonnel ActivateOrganization MaintainSecurityConductDoseAssessment Protective ActionRecommendations OperateJointNewsCenterDispatchFieldSurveyTeamsObtainPASSSampleActualActual"Actual"ActualActualActualActualActual-3""

ActualCallupofpersonnel andfacilityactivation willbeperformed insequence.

Aseparate, off-hours mustering drillwillbeconducted duringtheweekofNovember9,1992.Fieldteamswillbedeployedandwilldemonstrate appropriate fieldmonitoring techniques andcommunications withrespective emergency responsefacilities.

Aminimumof1onsiteand2offsiteteamswillbedeployed.

1-4 SINlULATIONSoRespiratory protection andprotective clothingwillbesimulated byonsite/offsite surveyteams.In-Plantteamswilldonrespiratory protection andprotective clothingprescribed byHealthPhysicsandChemistry personnel according topostulated scenarioplantconditions.

oIngeneral,Exerciseparticipants shouldfollowapplicable plantprocedures ascloselyaspossible, andwillbestoppedbyControllers beforeactualequipment ismanipulated (exceptPASS).Simulated repairsandothercorrective actionsshouldbedescribed toController-

/Evaluators asfullyaspossible.

oActionsinvolving ventilation ofgasfumesfromScreenhouse (e.g.breakingwindows)shallbesimulated.

oSecurityinterrogation ofsuspected individuals shallbesimulated.

Norealemployeeorcontractor namesshallbecommunicated.

1-5 UMIVIARYFPRPSEDFSITEACTIVITIES Itisanticipated thatWayneandMonroeCountiesandNewYorkStatepersonnel willparticipate toperformthefollowing minimumfunctions:

1.CommandandControl2.DoseAssessment 3.JointNewCenterStaffing4.Protective ActionDecisionmaking 6.Communications 1-6 SECTION2.0EXERCISEINFORIVIATION

2.0 EXERCISEINFORMATION

2.1ExercieParicians2.1.1Theparticipants intheExercisewillincludethefollowing:

ROCHESTER GASANDELECTRICCORPORATION A.FaciliiesManaemenandSuorPersonnel 1.Simulator ControlRoom2.Technical SupportCenter(TSC)3.Operations SupportCenter(OSC)4.SurveyCenter(SC)5.Emergency Operations Facility(EOF)6.JointEmergency NewsCenter(JENC)7.Engineering SupportCenter(ESC)B.EmerencResonseTeams1.Radiation SurveyTeams(RSTs)2.FirstAidTeam(ifnecessary) 3.Emergency OSCTeams4.SecurityForce5.PostAccidentSamplingSystem(PASS)Team6.Chemistry/Health PhysicsSupport7.FireBrigade(ifnecessary) 2.1.2OFFSITEAGENCIES/ORGANIZATIONS Participation ofthefollowing agencies/organizations isexpected:

A.Federal1.NuclearRegulatory Commission 2.NationalWeatherServiceB.State1.NewYorkStateEmergency Management Office2.NewYorkStateDepartment ofHealth3.NewYorkStatePolice4.OtherSupporting StateAgenciesC.Local1.WayneCounty2-1 2.MonroeCounty3.OtherSupporting CountyAgencies2-2 ExerciseOrnizaionTheorganization forthisExercisewillconsistoftheExerciseCoordinator, theControllers, thePlayersandtheObservers, asfollows:TheExerisCrinrwillcoordinate Exercisepreparations including thedevelopment ofthescenarioandcontroller inputmessages.

HewillcontrolallaspectsoftheconductoftheExercise, prepareaconsolidated evaluation andcritiquereportattheconclusion oftheExercise, andprepareandfollowuponanitemizedlistofcorrective actionsrecommended asaresultoftheevaluation andcritique.

lifidpIIdpttfollows:A.ALeadController isassignedtoeachemergency responsefacility.

TheLeadController isresponsible forallController, Evaluator and=Observeractivities forthatfacilityand,ifappropriate, itsassociated teams.Controllers forteamsorsubareasofafacilityreporttotheLeadController ofthatfacility.

B.TheControllers willdeliver"Exercise Messages" tothedesignated PlayersatvarioustimesandplacesduringtheExercise, injectordeliveradditional messagesasmayberequiredtoinitiatetheappropriate PlayerresponseandkeeptheExerciseactionmovingaccording tothescenarioandExerciseobjectives, observetheExerciseparticipants attheirassignedlocations, andprepareevaluation forms.Controllers/Observers submitwrittenrecommendations oncorrective actionstotheLeadController, whointurnsummarizes allcommentsforsubmittal totheExerciseCoordinator priortothescheduled critique.

TheControllers willbeprovidedwithalistofinstructions intheExercisescenario.

C.Personsdesignated asControllers/Observers foragivenfunctionwillalsobeassignedasEvaluators ofthatfunctionwhenfeasible.

Evaluators willrecordtheirobservations usinganevaluation formandproviderecommendations oncorrective actionstotheLeadController inwhosefacilitytheyevaluateexerciseperformance onthebasisofstandards orrequirements contained intheappropriate Emergency Plan,Implementing Procedures, andExercisemessagesasdescribed herein.Theywilltakesteps,wheneverpossible, tocollectdataonthetimeandmotionaspectsoftheactivityobservedforpost-Exercise useforimplementing improvements.

2-3 nrllerswillbinifiewrinrnIrinain"Cnrlier".wihwhi2.2.3~PI~rincludeGinnaStationandotherRochester GasandElectricCorporation personnel assignedtoperformemergency functions, asdescribed intheEmergency PlanandImplementing Procedures.

Playersfromoffsiteorganizations andagencies(county,Stateandprivateindustry) areparticipants intheExerciseasdescribed intheirrespective Emergency PlansandStandardOperating Procedures.

2.2.4OilOs,~rv rsfromtheRochester GasandElectricCorporation andotherorganizations maybeassignedtoparticipate intheExercisesolelyforthepurposeofobserving/evaluating Exerciseactivity.

Theywillbeprovidedwithorientation information andappropriate Exercisepublications.

Observers willbearoriatelidenifidbwearinarmbandsrbades.Federalaenobrvrswillbeidenifiedbwearinarmbandsorbadewihleerinstatin"NRC"or"FEMA".Vi~QiirfromtheRochester GasandElectricCorporation andotherorganizations maybeassigned, onalimitedbasis,forthesolepurposeofobserving Exerciseactivities forpersonaleducation.

Theywillbeprovidedwithorientation information andappropriate Exercisepublications.

Viiorswillbeidentified bwearinarmbandsorbadesstain"Visior".2.2.5Requeststoparticipate asaVisitorshouldbemadeinwritingandcontaintheVisitor's fullname,homeaddress,phonenumberandorganization affiliation.

Requeststoparticipate asVisitorsmustbesubmitted totheRGRECorporate NuclearEmergency Planner(CNEP)nolaterthanoneweekbeforetheExercise.

2.3EmerencResonseFacilities DuringtheExercise, specialfacilities mustbeactivated tomanage,assessandsupportemergency response.

2-4

R8cEFACILITIES TheRochester GasandElectricCorporation Emergency ResponseFacilities are:A.Similator ControlRoomTheGinnaSimulator ControlRoomwillbeused.ControlRoomemergency responsemeasureswillbeexercised underthedirection oftheExerciseShiftSupervisor, actingastheEmergency Coordinator, untilrelievedbythePlantManageroralternate,

'TheSimulator ControlRoomislocatedintheSimulator BuildingnexttotheGinnaTrainingCenter.B.Technical SuortCenerTSCWhenemergency conditions escalatetoanAlertstatusorhigher,coordination oftheemergency responsewillshiftfromtheControlRoomtotheTSC,locatedofftheMezzanine LeveloftheTurbineBuilding.

TheTSCDirectorrelievestheShiftSupervisor asEmergency Coordinator anddirectsactivities fromtheTSC.TheTSCisthelocationfromwhichtechnical management personnel utilizeinformation onPlantstatusprovidedintheTSCtosupportactionsbeingperformed intheControlRoom.TheTSCservesastheprimarycommunications sourcetotheNRC,OSC,EOFandoffsiteagencies, andwillperformotherfunctions oftheEOFuntiltheEOFisactivated.

C.0erationsSuortCenterTheOSC,whichislocatedintheTSC,providesalocationwhereemergency responseteamscanbeassembled andcoordinated duringanemergency.

TheOSCwillbeactivated foremergency conditions classified asanAlertorhigher,andmaybeactivated foranUnusualEventatthediscretion oftheEmergency Coordinator.

D.Emerenc0erationsFacilitEOFTheEOF,whichislocatedinthebasementof49EastAvenueinRochester, willbeactivated foremergency conditions classified asaSiteAreaEmergency orGeneralEmergency (optional fortheAlertstatus).TheEOF/Recovery Managerdirectstheactivities oftheEOF/Recovery Organization fromtheEOF.2-5 TheTSCEmergency Coordinator reportstotheEOF/Recovery Manager.TheEOFisthecommandpostforcoordination ofresponsemeasureswithoffsiteorganizations, assessment ofradiological andenvironmental conditions anddetermination ofrecommended protective actionsforthepublic.TheEOFalsoprovidesdirection andmanagement ofrecoveryoperations.

E.JoinEmerencNewsCenterJENCTheJENC,whichislocatedat89EastAvenueinRochester, providesthepointofcontactforthecoordinated releaseofnewsandinformation tothenewsmediaandthegeneralpublic.TheJENCisstaffedbyRG5ECorporation, County,StateandFederalofficials andwillbeactivated foremergency conditions classified asanAlert,SiteAreaEmergency orGeneralEmergency.

2-6 ExerciseConductOverviewTheExercisewillsimulateanabnormalradiological incidentatGinnaStationwhichwillstartwithanUnusualEventandescalatetoaSiteAreaEmergency.

DuringthecourseoftheExercise, inordertoevaluatecoordination withappropriate Stateandlocalagencies, incidents willarisewhichrequireresponsebyoffsiteemergency responseorganizations.

TheExercisewillalsosimulateanoffsiteradiological releasewhichwillrequiredeployment ofGinnaStation,andWayneCountyandMonroeCountyradiological surveyteamsforoffsitemonitoring.

TheconductoftheExercisewilldemonstrate theeffectiveness ofselectedorganizations, personnel, functions, and/oractivities oftheappropriate Emergency PlansandImplementing Procedures.

Thesimulated emergency willthende-escalate.

TheRecoveryPhasewillbeinitiated andtheExercisewillthenbeterminated.

ActionsEmergency responseactionsduringthesimulated emergency willinclude:recognition andclassification ofemergency conditions; assessment ofonsite/offsite radiological consequences; alert/notification andmobilization ofemergency responseorganizations; implementation ofin-Plantcorrective actions;activation/operation ofemergency responsefacilities andequipment; preparation ofreports,messagesandrecord-keeping; andrecommendation ofprotective actions.2-7.

Communications TheExercisewillalsodemonstrate theeffective useofcommunications systems.Anactualemergency operation usuallyrequirestheextensive useofbothtelephone andradios.Thetelephone istheprimarymeansofcommunication andwillbeattempted first,withradioasabackup,unlessradioistheonlymeansavailable.

Separatetelephone numberswillbeusedforController communications topreve'ntthePlayersfromlearninginadvanceofthesituation towhichtheyaretobesubjected duringtheExercise.

Closecooperation andcoordination amongControllers isessential duetothenumberofpersonsassignedtotheController role.RGSEoffsiteradiation surveyteamsareequippedwithportableradios,andareprovidedcellulartelephones forback-upcommunications.

Surveyteamcontrollers areencouraged tousethecellulartelephones ifclarifications ofcontroller instructions arerequiredwhileinthefield.Controllers LeadControllers willbestationed intheSimulator ConrolRoomOSCTECECFJCE~CEDC.0lyLdd<<IIdlfyExercisemessagesorinitiatefreeplaymessages.

A.TheSimulator ControlRoomwillbethecentralpointfororganization ofExercisemessagesandisthekeytoensuringthattheExerciseprogresses onschedule, Simulated Plantparameters willbeprovidedtotheSimulator ControlRoomoperators eitherbypanelindications displayed intheSimulator ControlRoomorthroughplantdataandstatussheets.Sinceitisnecessary thattheemergency escalatetotheGeneralEmergency level,itmaydyFI-dldlI<<I.T~dwillacceheExercisemesesaswrien.Ifcorrective actionsarepostulated thatwouldterminate theemergency, theyshouldbeidentified totheLeadController intheaffectedfacilitysothatthescenariowillprogressasdesigned.

TheExercisePlayersareexpectedto"freeplay"thescenariototheextentpractical.

Notifications of,andcontactwith,supervisors, Plantmanagement andoffsiteagencieswillbemadeinaccordance withtheEmergency PlanImplementing Procedures.

2-8 B.TheTSCwillbethecoordination pointforonsiteemergency responseactivities.

TSCperso'nnel willalsocoordinate offsiteemergency responseactivities untilactivation oftheEOF.TSCandEOFpersonnel willbeawarethatiftheExerciseistoproceedasplanned,andiftheoffsiteorganizations aretobeexercised, itmaybenecessary topostulate non-credible situations.

Thisisdonetoensurethatvariousaspectsoftheonsiteandoffsiteemergency responseorganizations aretested.TSCanEOFrsonnelwillcExercisemessaeswrin.Thinndrninooxlainwhasiuaionc uldnoccroratshouhididoccur.Ifcorrective actionsarepostulated thatwouldterminate theemergency, theyshouldbenotedtotheLeadController.

TheExercisePlayersintheTSCandEOFareexpectedto"freeplay"thescenariototheextentpractical

~Notifications of,andcontactwith,supervisors, Plantmanagement andoffsiteagenciesshouldbemadeinaccordance withtheEmergency PlantImplementing Procedures.

Thescenarioisdesignedtoactivateonsiteandoffsiteemergency responsecapabilities.

TheLeadController mayinjectotherinformation orchangeamessagetoensurethattheExerciseprogresses asplanned.~PlaersThesuccessoftheExerciseislargelydependent uponPlayerreaction, Playerknowledge oftheirappropriate Emergency PlanandImplementing Procedures andanunderstanding ofthepurposeoftheExercise.

Initialconditions whichwillaffectPlayeractionorreactionwillbeprovidedtothePlayersatthetimetheExercisebegins.However,mostoftheelementsoftheExerciseplaywillbeintroduced throughtheuseofcontrolled Exercisemessageformsandmessagesgenerated byPlayersasaresultoftheparticular emergency activityperformed.

Players,therefore, areresponsible forinitiating actionsduringtheExerciseinaccordance withinstructions, responsibilities andtasksfortheirparticular function.

EachPlayerwilladvisehis/herController priortoperforming requiredemergency actionsduringtheplayofsimulated activities toensurethatthePlayeriscreditedforhis/heractions.2-9 Playersareremindednottobeexcessively concerned withthemechanics orcauseoftheExercisescenario.

ThisExerciseisdesignedtoevaluatetheEmergency Plan,Implementing Procedures andemergency preparedness trainingprogramandnottheprobability, feasibility ordetailedmechanics ofthesimulated accident.

Additionally, theExerciseisatrainingvehicleforRochester GasandElectricCorporation personnel topracticecoordinating withoutside1i*iiiIdgyi<<.~lhnnnimrvmnhmeohirninrinhExrisnubmihmothearoriateConrIIrahenclusionofheExercise.

2.5PrecauionsandLimltaionsThissectionprovidesinformation forallExerciseControllers andObservers relatedtotherulesandguidelines tobefollowedthroughout theconductofthisExercise.

Priortoinitiation oftheExercise, apre-Exercise briefingwillbeheldtoreviewtheentireExerciseprocesswithalltheExerciseControllers andObservers identified inthismanual.A.ShoIdnimrinhcourseoftheonofhiExercisenaalemerencsiuatinariseIIiviisandcommunica ionsrelatedtoheExreisewillbesusended.Itwillbetheresponsibility ofanyExerciseController orObserverthatbecomesawareofanactualemergency tosuspendexerciseresponseinhis/herimmediate areaandtoinformtheLeadExerciseController ofthesituation.

Uponnotification ofanactualemergency, theLeadExerciseController maynotifyallotherControllers/Observers tosuspendallExerciseactivities.

TheLeadExerciseController willmakeadetermination atthatpointwhethertocontinue, placeatemporary holdon,orterminate theExercise.

B.Should,atanytimeduringthecourseoftheconductofthisExercise, anExerciseController orObserverwitnessanExerciseparticipant undertake anyactionwhichwould,intheopinionoftheController/Observer, placeeitheranindividual orcomponent inanunsafecondition, theController/Observer isresponsible forintervening intheindividual's actionsandterminating theunsafeactivityimmediately.

Upontermination oftheactivity, theController/Observer isresponsible forcontacting theLeadExerciseController andinforming himofthesituation.

TheLeadExerciseController willmakeadetermination atthatpointwhethertocontinue, placeatemporary holdon,orterminate theExercise.

C.Nopressurization offirehoses,discharging offireextinguishers, 2-10 orinitiation ofanyfiresuppression systemswillberequiredfortheExercise.

D.Manipulation ofanyPlantoperating systems(exceptforthePASSsystem),valves,breakers, orcontrolsinresponsetothisExerciseareonlytobesimulated.

Thereistobenoalteration ofanyPlantoperating equipment, systemsorcircuitsduringtheresponsetothisExercise.

E.Allrepairactivities associated withthescenariowillbesimulated withextremecautionemphasized aroundoperating equipment.

F.Alltelephone communications, radiotransmissions andpublicaddressannouncements relatedtotheexercisemustbeginandendwiththestatement, "Thisisanexercise".

ShouldaController orObserverwitnessanExerciseparticipant notobserving thispractice, itistheController's/Observer's responsibility toremindtheindividual oftheneedtofollowthisprocedure.

G.AnymotorvehicleresponsetothisExercise, whetheritbeambulance, firefightingequipment, police/security vehiclesorfieldmonitoring teams,shouldobserveallnormalmotorvehicleoperating lawsincludedpostedspeedlimits,stoplights/signs, onewaystreets,etc.H.ShouldanyonsitesecurityactionsberequiredinresponsetothisExercise, participants aretocooperate asdirectedbytheSecurityForce,andsecurityrepresentatives aretobeprudentandtolerantintheiractions.Exerciseparticipants aretoinjectasmuchrealismintotheExerciseasisconsistent withitssafeperformance; however,cautionmustbeusedtopreventover-reaction, Caremustbetakentoassurethatanynon-participating individuals whomayobserveExerciseactivities oroverhearExercisecommunications arenotmisledintobelieving thatanactualemergency exists,AnyExerciseController orObserverwhoisawareofanindividual orgroupofindividuals intheimmediate vicinitywhomayhavebecomealarmedorconfusedaboutthesituation, shouldapproachthatindividual orgroupandexplainthenatureoftheExerciseanditsintent.2.6Evaluation andCritiueTheExercisewillbeevaluated byControllers/Observers whohave2-11 expertise in,orqualifications toevaluatetheactivityintheirassignedlocation.

Controllers/Observers willevaluateExerciseperformance onthebasisofrequirements contained intheEmergency PlanImplementing Procedures andExercisemessages.

Controllers/Observers willprepareevaluation formsandproviderecommendations oncorrective actionstotheExerciseCoordinator.

AftertheExerciseiscompleted, theExerciseCoordinator willconductapost-Exercise critique.

Deficiencies intheEmergency Plan,Implementing Procedures, emergency preparedness trainingprogram,facilities, equipment and/orotherareaswillbeidentified throughthecritiqueprocess.Thedeficiencies willbedocumented bytheExerciseCoordinator andcorrected bytheindividuals whohaveresponsibility intheareaoftheidentified deficiency.

Controller andObserverinformation iscontained inSection5.0.Thescheduleforthecritiques isshowninSection6.0.2-12 SECTION3.0TRAVELINFORMATION

3.0 TRAVELINFORlVIATION

ThissectionoftheGinnaStationExerciseManualprovidestravelinformation tothoseindividuals fromRGSE,otherutiIities,local/State/Federal government, and/orotherorganizations whowillparticipate/observe theExercise.

Permission forVisitorstoobservetheExercisemustbeobtainedfrom:Corporate NuclearEmergency PlannerRochester GasandElectricCorporation 49EastAvenueRochester, NY14649-0001.

3.1DirecionsoGInnaNuclearStaionGinnaStationislocatedonthesouthernshoreofLakeOntarioinWayneCounty,NewYork,approximately 24milesnortheast ofRochester, NewYork(seeFigure3.1).3.1~1AirSeveralairlinesprovidepassenger servicetotheRochester-Monroe CountyInternational Airport.3.1.2CarA.Severalcarrentalagenciesareavailable attheRochester-Monroe CountyInternational Airporttoproviderentalvehiclesforgroundtransportation toGinnaStation.B.Personstraveling fromtheRochester-Monroe CountyInternational AirportviaautoshouldtakeRoute204EasttoRoute390South.Route390becomesRoute590asoneproceedsaroundtheOuterLoop.FollowRoute590NorthtoRoute104East.FollowRoute104toRoute350(OntarioCenterRoad).Turnleft(North)andproceedtoGinnaStation.Totaldistanceisapproximately 40miles.3.2Directions totheEOFESCandJENC3.2.1AirFromtheRochester-Monroe County,International Airporttake204to390North,490EastintotheCityontotheInnerLooptotheEastAvenueramptothethirdsignallight.Turnright.3-1 3.2.2CarFrom.theThruway,useExits45or46intoRochester andtheInnerLooptotheEastAvenuerampasin3.2.1.3.2.3TogettotheEmergency Operations Facility(EOF)andEngineering SupportCenter(ESC),gototheintersection ofEastAvenueandChestnutStreet(blacksquareonmap).EOFandESCarein49EastAvenue.TheJENCisat89EastAvenue(seeFigure3.2).3.3Accommodations Hotel/motel accommodations maybeobtainedatthefollowing locations:

DepotHotel,Pittsford MarriottHotel,GreeceRedRoofInn,Henrietta Brookwood Inn,Pittsford Woodcliff Lodge,Perinton(716)381-9900(716)225-6880(716)359-1100(716)248-9000(716)248-48103-2 LAKEONTARIO/GINNASTATION+IoiNNOTTOSCALE181b)OaOH'I0CldnkRikb35o~~NemZQg0ROCHESTER ROCHESTER-MONROECOUNTYAIRPORT0A00Z 10NIROCHESTER ANOVICINITY~~ewtasc>>~IOaaW

~~~~~Oadd~~.I~~sscsscsaCsdIsles'OaCOerasasasadtll lm~~~Iesaaeeeca%Iceaaa~~tssa~ggs~~IIIaaeI~I~Cjs>>>>F964K4.I.4-II/IŽ~srII)LlIIIIlsssrriJCC (O'~)&NE4LI44a A@ISbtCs2oo+3'>>@agSS'e>40o(VI~)III~IIoaC>>aIIIIIJ/CIgrI~ls~e>>~I~~I'II~~~Irs0II~I1)tv-'I~I~~I~II~I~~W~~~~~QQQrtII~te~FC5CJ'&LCIt~~~I~I~II~~I~I~~~Is~~te~~r,~~aees\~~~II~~~COa~~I~~II~~~~I~I~~~~Csess~I~Is~I~sa~Ie~~g~I~I~>>aIII~~rr~s~I~~III~~~~~~~~~I~Ic~I~~'~~IIIICtee~tIII'll~e~r~~~~~0~~~~OagIO>>Oals>>eetCaaeOa~ICt~~\I~~~~I~~~I~~~~~d~~~se~I~>>sa>>~~~~C~~I~~I~I~Igl~d,a~II~CdCC~IIIIsII(~,~~ICO ROCHESTER CENTRALBUSlNESSO(STR)tThlAŽ43PIIo/+g~IrC~C4~I1~~II~pt.g'~rI~+mylI/~IrI//zItrr~I~Sr4Government OfficesCIlyMallb~1CItypuotICSolelyburldlnbbaCrrlcCenter~sCountyOttlcebultdlnbblFederalbulrdlntt br1HallotJustlC~~.l8Hotels8MotelsCadillacwol~IMolrdertrtocnet~-St~yrereIoc:s R~Mt-H4~S,OlblblC5CPointsofInterestAmtreaOeeeenber So~IceboatmenSchoolotMusicbestntsnyhoatreGenesoobreweryGreyhound busStetIonltodas'sMernOltlcesMI4town~taceAocnostor ChsrnoerotColnrnerce tttMewoCenterAundelt.lttrery SHOnbMueeumyrellwoye bueStationurerMomort~tXoroaSoueroYMCA0EParksCtOowntownFestlssrSir~01GenoeseCrossrosos osr~01GenoeseGatewayoarsdIt.lttorty eot~GreenC1Manhattan SouaroFereA1Airertrenl OSISC1Weenlnt]tdn Sduar~C1blClOaOl~lOl01sd]50]A]brFigure3.3 Fire3.4PART'll.-SEC.I-Proc.0ATTACNENT iX/'hSTATEKQC-ASSWi',t"~O,p'ge+.~'ll,~I~8~noirii~Cem'h~~lft~~~4l~ilelJtsa~~~J~r~iI+~Wi~..~'y%go~/$TATggoyM~>8UILOINQ~whup.~.'~aj4ajaFC~shirt~

aIl)IetLATA-~aleea~Ve45LDT0)acr~jCa4JF4OIWY/4014urDLotLrJt)l~~s4010I0100-ANlltg~22Sub)vclVtaj.IppMsNALDNOIL'OCXACACULTUAj AlglNAA4415 OA5ea4LT40 Ckljlaj>CAMALKkCjCIVIL5LAV%4CCNALCTKLVAL

$41VC45HCAIWshlaTle%WLITAAYAL'DIIAVALAHAlASATCOADCTHT41$41vC%4VILDWG5OCAL54ilvC4$~....~.51*'lleoacj51AllKLC4ACADTVY.....,

TATA'Isots AADSIAA~4,TA~POATATION.

...T.M.I,Q~"I'"05'tel..It4.p.........'I'tl

..~~.~~....11~...LNj~~~~I,L1.1AgQgLV4s~gKI1HI jlI4$4.Ol5INLOMlaId."JlAmnlArtmtDgPl&mX7ESC1!mooEDOsClrt4O0~m401~iPg&AeCA4l slTO444VMX44IT44WSMTIM4fr0$~1g---Ooetown N.SN~c&eaHeaI~~as~IbaaareVw~~CTIT4jar~~~jars'~

O~IPSTATEOFF)CEBUILDINGCAMPUS1220NASHINGTONAVENUEALBANY.NEWYORKQlaA&I4IAMslttaskarflaaaltatargyIIQlsIaa4AorA4+cessINN4aocsr&eearel~IIIllsFROHTHESOUTHorWESTtaketheN.Y,S.Thruway(l-.87Northbound/l-90Eastbountof~5t.'i.Aftertiletollboothteryc'L'05tralyhtullI-9JtOfait3.*FROHTHENORTHtaketheAdirondack Northway(l-87)SouthExitlE.ProceedEastonl-90toExit3.'RONOOWtITOWII ALBANYtake1-90Westbound toExit3.'ROH00WtITOWti ALBAtIYtakeWashington AvenuetoWesternAvenue(Rte20)totheStateOfficeBuildingCampus.tpn SECTION

4.0REFERENCES

/ABBREVIATIONS

-ACRONYMS 4.1a.s.sReferences 10CFR50.47,50.54,AppendixE44CFR350.9NUREG-0654/FEMA-REP-1, Rev.1,ririaforPrrinnEvlinfRaioliIEmrenRenPinnPrrneinSoofNuclearPowerPln4.1.104.1.11RGRENuclearEmergency ResponsePlan(NERP)GSRadiation Emergency PlanImplementing Procedures (EPIPS)GSLicenseandTechnical Specifications GSPipingandInstrumentation DrawingsNewYorkStateRadiological Emergency ResponsePlanMonroeCountyEmergency Preparedness PlanWayneCountyRadiological ResponsePlanINPOEmergency Preparedness DrillandExerciseManual 4.2Abbreviations

-AcronmsA/EALARAAOVARMSARVATWSBASTCDCFRCVCRDOEDOE-IRAPEAL(s)EBSECECL(s)ENSEOCEOFEPAEPCEPIP(s)EPZERF(s)ERPAESCFEMAFRERPGSHALMHPHPNHVACINHBINPOJENCKlLALMLCOLOCALWRMOVMPCNERPArchitect EngineerAsLowAsReasonably Achievable Air-Operated ValveAreaRadiation Monitor(s)

Atmospheric ReliefValveAnticipated Transient WithoutScramBoricAcidStorageTankCivilDefenseCodeofFederalRegulations Containment ControlRoomDepartment ofEnergyDOEInteragency Radiological Assistance PlanEmergency ActionLevel(s)Emergency Broadcast SystemEmergency Coordinator Emergency Classification Level(s)Emergency Notification System(NRC)Emergency Operations CenterEmergency Operations FacilityEnvironmental Protection AgencyEmergency PlanningCoordinator Emergency PlanImplementation Procedure(s)

Emergency PlanningZoneEmergency ResponseFacility(s)

Emergency ResponsePlanningAreaEngineering SupportCenterFederalEmergency Management AgencyFederalRadiological Emergency ResponsePlanGinnaStationHighAlarmHealthPhysicist HealthPhysicsNetworkHeatingVentilation AirConditioning Inhibited (AlarmSuppressed)

Institute ofNuclearPowerOperations JointEmergency NewsCenterPotassium IodideLowAlarmLimitedCondition ofOperation LossofCoolantAccidentLightWaterReactorMotor-Operated ValveMaximumPermissible Concentration NuclearEmergency ResponsePlan4-2 4.2Abbreviation

-AcronmsCn'RCOSCOOSOOSPAG(s)PAR(s)PASSPIOPWRRCPRCSRHRRGRERSTSCSlSPINGTSCNuclearRegulatory Commission Operational SupportCenterOutofService(onsite)OutofSequence(offsite)Protective ActionGuide(s)Protective ActionRecommendation(s)

PostAccidentSamplingSystemPublicInformation OfficerPressurized WaterReactorReactorCoolantPumpReactorCoolantSystemResidualHeatRemovalRochester GasandElectricCorporation Radiation SurveyTeamSiteContingency (orSurveyCenter)SafetyInjection HighRangeEffluentMonitorTechnical SupportCenter4-3 SECTION5.0CONTROLLER ANDEVALUATOR INFORIVIATION

5.0 ONTROLLER

ANDEVALATORINSTRUTIONSEachController andEvaluator shouldbefamiliarwiththefollowing:

a.Thebasicobjectives oftheExercise.

b.Theassumptions andprecautions beingtaken.c.TheExercisescenario, including theinitiating eventsandtheexpectedcourseofactionstobetaken.d.Thevariouslocations thatwillbeinvolvedandthespecificitemstobeobservedwhenatthoselocations.

e.Thepurposeandimportance oftheevaluation checklist andrecordsheets.5.1CnrollerInsrucions5.1.1Controllers willpositionthemselves attheirassignedlocations priortotheactivation ofthefacilityforwhichtheyhaveresponsibility (seeSection5.3).5.1.2Communications willbetestedtoensuresatisfactory communications amongControllers priortoExercisecommencement.

Allwatchesandclockswillbesynchronized withtheLeadSimulator ControlRoom.ExerciseController aspartofthecommunications testing.5.1.35.1.4AllControllers willcomplywithinstructions fromtheLeadController.

EachController willhavecopiesofthemessagescontrolling theprogressoftheExercisescenario.

Nomessageshallbedelivered outofsequenceorotherthanaswrittenunlessspecifically authorized bytheLeadController.

5.1.5Messagescontrolling theprogressofthescenarioarenotedwithanumber.Contingency messagesarenotedwithanumberfollowedbytheletter"X"(e.g.,10X).5.1.6EachonsiteController willhavecopiesoftime-related plantdatasheets.Datasheetswillbedistributed onlyintheControlRoom.Radiological andmeteorological datawillalsobeprovidedatlocations whereitisnormallyavailable.

5-1 5.1.7Controllers will~nprovideinformation tothePlayersregarding

.scenariodevelopment orresolution ofproblemareasencountered inthecourseofthesimulated emergency.

TheExerciseparticipants areexpectedtoobtaininformation throughtheirownorganizations andexercisetheirownjudgement indetermining responseactionsandresolving problems.

5.'1.8SomePlayersmayinsistthatcertainpartsofthescenarioareunrealistic.

TheLeadControllers havethesoleauthority toclarifyanyquestions regarding scenariocontent.5.1P9EachController willtakedetailednotesregarding theprogressoftheExerciseandtheresponses oftheExerciseparticipants attheirrespective assignedlocations.

EachController willcarefully notethearrivalanddeparture timeforparticipants, thetimesatwhichmajoractivities ormilestones occurandproblemareasencountered.

TheControllers willretaintheirnotesforthepurposesofreconstructing theExercisechronology andpreparing awrittenevaluation oftheExercise.

5P2Evaluation Instructions EachController/Evaluator willtakedetailednotesregarding theprogressoftheExerciseandtheresponseoftheExerciseparticipants attheirrespective assignedlocations.

EachController/Evaluator shouldcarefully notethearrivalanddeparture timesofparticipants, thetimeswhenmajoractivities ormilestones occurandproblemareasencountered.

Thestandards belowshouldbeusedbytheController/Evaluator toevaluateassignedareaspertaining totheemergency response.

Adualpurposewillbeservedbythisratingsystem.First,thecapability ofeachfacilityorresponseareawillbeevaluated andsecond,thesystemwillprovideavehicleforguidinganddirecting improvement.

Theratingscaleisasfollows:Good-Personnel andequipment generally performed betterthanexpected.

Anyerrorsorproblemswereminorandeasilycorrectable.

~gif-PIdlipgllypfdexpected.

Anyerrorsnotedwerenotsevereandcouldbecorrected withoutunduelabororexpense.~di-PIddipgllyfddlexpectations andtherewereseveralsignificant deficiencies noted.Thearea'sabilitytocarryoutitsfunctions wasdiminished.

NA-Notapplicable tothesituation ornotobserved.

5-2

Controller/Evaluator commentsshouldconsiderthedemonstration ofthefollowing facilityandteamevaluation elements:

5.2.1~~~FacilioAccurateandtimelydetermination ofemergency actionandclassification levels.oTimelyactivation andstaffingforeachclassification level.oFamiliarity ofpersonnel withappropriate emergency instructions, dutiesandresponsibilities.

oTimelynotification ofRochester GasandElectricCorporation, local,StateandFederalpersonnel/agencies (information updatesperformed).

oAdequacyofinternalinformation systems(i.e.,messagehandling,

displays, statusboardsandmaps).oProperlycontrolled documentation andaccurate, timelyrecord-keeping.oUtilization ofcorrectcommunications procedures andtechniques.

oCapability offacilitysupervisors/directors tointerface withpersonnel andcoordinate facilityactivities.

oConsideration ofpersonnel safety(exposure control).

oAdequacyofinterface betweenemergency responsefacilities.

oAdequacyofequipment andsupplies.

oTimelyinitiation ofonsiteprotective/corrective actions.oDevelopment ofprotective actionrecommendations.

oRadiological surveysandassessment ofplantdamageandhazardous conditions performed.

oTimelyrequestofemergency supportservices.

oCoordinated, accurateandorderlydissemination ofinformation tothenewsmedia.oProperassumption ofcommandandcontrol,5-3 5.2.2TeamoTimelynotification andactivation.

oAdequacyofstaffing.

oFamiliarity'ith appropriate emergency procedures, dutiesandresponsibilities.

oAvailability andutilization ofproperequipment, oPerformance ofcontamination/decontamination control.oProperinterface withemergency supportpersonnel.

oUtilization ofcorrectcommunications instructions andtechniques.

oAvailability ofreferenced documents toteammembers.oUtilization ofproperradiological controlpractices (i.e.,accesscontrol,protective

clothing, shielding, staytime).oPerformance ofradiological surveys.oTimelyandproperperformance ofdamageassessment.

oProperlymaintained surveyrecordsandmaps.oAdequacyofbriefingsessionspriortodispatch.,

oDirection andcontrolbyteamleaders.oTimelyrequestsforoffsiteassistance ifrequired.

oCoordination andinterface betweenemergency responseteammembers.oProperinterfaces withplantsupervisory personnel.

Controllers/Observers willrecordtheircommentsforthepurposeofreconstructing theExercisechronology andpreparing awrittenevaluation oftheExercise.

5.3Personnel AssinmentsTable5.1liststhepersonnel assignments fortheon-siteController organization.

5-4 EvalionPckaesThefollowing evaluation packageswillbeprovidedtotheappropriate Controllers/Observers atthepre-Exercise briefing:

Simulator ControlRoomTechnical SupportCenterOperational SupportCenterSurveyCenterEmergency Operations FacilityJointEmergency NewsCenterHealthPhysicsPersonnel DoseAssessment (TSCandEOF)Radiation SurveyTeams(SCandEOF)Post-Accident SamplingSystemFireBrigadeEngineering SupportCenter5-5 TABLE.1Thefollowing personnel havebeendesignated toactasControllers duringthe1992Exerciseactivities (SEEATTACHEDLIST).5-6 POSITIONCONTROLLER LISTExerciseCoordinator R.BeldueControlRoom(Simulator)

D.Hudnut(Lead)J.O'ooleT.WhiteJ.ZulawskiControlRoom(Real)D.PetersonTechnical SupportCenterLeadT.Alexander Technical 8Operations Assessment B.ZollnerK.MaskerSecurityR.WoodR.TeedDoseAssessment HealthPhysics8Chemistry P.PolfleitF.PudduCommunications 8DataFlowS.PoultonOperations SupportCenterLeadJ.HuffJ.KnorrFireD.Biedenbach M.Cavanaugh Operations W.StieweS.Carter POSITION.CONTROLLER LISTIBCT.Joachimczyk E.McGrattan Mechanical S.MeisterE.GrausG.GibaudJ.LieseElectrical R.YatesR.MarriottPostAccidentSamplingSystemM.CliftonTBDSurveyCenterLeadRedTeamBlueTeamGreenTeamYellowTeamOrangeTeamWhiteTeamPersonnel Coordinator J.SchultzR.Mastrella J.EdlerJ.MazzeoP.PhelanJ.GrzybekD.BryantM.E.DanglerEmergency Operations FacilityLead8Operations W.BackusCommunications 8DataFlowB.Stanfield POSITIONCONTROLLER LISTDoseAssessment R.WattsN.Kiedrowski-SurveyTeamK.HartM.Burgess-GeneralEngineering SupportCenterJ.NeisC.AndersonJ.Bergstrom JointEmergency NewsCenterNationalWeatherServiceF.OrienterG.English6-9 GINNASTATION1992EMERGENCY EXERCISE~PB~LI~l~FDRMATI~RIINORCONTRDLANOSPPEPHNELLUUETIDHS FIIRTHEEVALUATED EXERCISEAsignificant aspectofemergency responseistoprovidethenewsmediaandgeneralpublicwithaccurateandtimelyinformation abouttheincident.

Publicperception andreactionareinfluenced bytheinformation relayedtothem.ToensurethattheRochester GasandElectricCorporation Emergency Organization ispreparedtodealwithoutsideinquiries duringanincidentattheGinnaStation,theexerciseprovidescertainelementsthattestPublicInformation andRumorControlactivities.

DuringthecourseoftheExercise, theJointEmergency NewsCenter(JENC)willbeactivated andexercised.

TheRG5E"SpousePhone"willalsobemannedbytheRGSEMedicalDepartment.

ExerciseControllers havebeenselectedtotesttheRumorControlandNewsMediaContactStaffs,aswellastheJENC.Controllers willactasconcerned

citizens, employees, employeerelatives andasmembersofthemedia,posingquestions tothestaffs.Whenactingasmembersofthemedia,controllers shallmakeupanameandamediaoutlet(printorelectronic) locatedouu,~idoftheRochester area.Eachtimearumorcontrolmessageisdelivered, adifferent fictitious nameandaddresswillbegiven.Thephonenumbertobegivenwillbethenumberfromwhichtheexercisecontroller iscallingsoastoallowthecountyRumorControlperson(s) toreturncallswithappropriate information, ifnecessary.

Theexercisecontrollers shouldmaintainthethemeofeachrumorcontrolmessageandanswerinquiries ofthecounties'umor Controlpersonsappropriately.

Thefollowing pagesdenotequestions thatthesecontrollers canuse.Thequestions aregroupedbytimeinrelationtotheeventsspecified inthe,ExerciseScenario.

TheControllers areallowedtousequestions previously utilized.

TheleadJENCController shallverifythattheexerciseisadheringtoschedule, otherwise timeadjustments willbenecessary.

Spaceisprovidedforcontrollers tomakenotesontheresponse.

Controllers neednotusethequestions herein;freeplayisencouraged.

However,controllers mustnotgetcarriedawaywithunusualorpointless questions.

Whencallinginquestions,

~alwas~re~edgggs~lon~wih"THISISANEXERCISE".

IfyouareplayingareporterattheJENC,developfreeplayquestions basedontheinformation givenduringthebriefing.

Additionally,ask questions aboutRGSE,theStateorcounties, GinnaStation,radiation, state/county/utility interface, protective actions,etc.Questions andrelevanttelephone numberswillbedistributed atthespecialPre-Exercise Controllers Briefing.

5-10

~qhIllPhilIf<<l2IgllyfRGRE:hElfCyRC<<IG~qhIlqIIIIdp<<pldlld~Ah*Il2IIlgh"RpPhIhRGEEMdlDepartment.

5-11 GINNASTATION1992EMERGENCY EXERCISEATIACHMENT1PUIIDINFDNMIITIDN

~DUNTlNNTIME0930~ThisisfromTVStationWWUV.We'eheardthatthereisanincidentattheGinnaNuclearPlant.Canyoutelluswhatishappening?

~Myhusband's aWayneCountySheriff's Deputy.Hesaidhe'sheardthatthere'ssomesortofproblematthenuclearplant.~Whatishappening there?~Howdangerous asituation isit?0915~ThisisfromtheAssociated Press.Iunderstand thatyouhaveanincidentattheGinnaNuclearPlant.What'sgoingonupthere?~Howextensive istheproblem?~Wheredidthetroublestartintheplant?~Isitundercontrol?~What'sthestatusoftheplant?~Whatkindofhazardsareinvolved?

~Haveanyworkersbeeninjured?~Ifsowhatistheextentoftheirinjuries?

~Whataretheirnames?~Whataretheirjobfunctions?

~Isthesafetyofthepublicthreatened?

~Atwhattimewillyouhaveapressconference?

~We'dliketosendsomeonetotheplant,forinterviews andphotos..Where dotheygo?5-12 0930~ThisisfromTVStationWRRO.WehaveareportyouhavesomeseriousproblemsatGinnaStation.Wouldyoutellourlisteners thestory?~Weheardtheplantisreactorisnolongerundercontrol-isthattrue?~Istheplantexperiencing anuncontrolled releaseofradiation?

~Howdoyouknow?~Whoisinchargeoftheemergency?

~Whatishis/hertitle?~Whyaretheyincharge?~Whatemergency classification areyounowunder?~Wasthereactordamaged?~Didyouevacuatethesite?~Whynot?~Areyougoingtoevacuatethepubliclivingbytheplant?~Isthereactorundercontrol?~Doyouhaveapressconference scheduled?

~Atwhattime?5-13 0945~Whatishappening atGinna?~Istheplantstillunderyourcontrol?~Havethefederalauthorities beennotified?

~Whichones?~Whatwilltheybedoing?~Hasassistance beenrequested todealwiththiscrisis?~lsthereanydangertothepublic?~WhatisgoingonatGinna?~Hasthesituation beenresolvedorarethingsgettingworse?~Areyouevacuating thesite?~Areyougoingtotellthepublictoevacuatetheareaaroundtheplant?~HasGovernorCuomobeennotified?

~Havethesirensbeenactivated?

~Ihearthereisatoxicchemicalspill,inadditiontotheradiation leakattheplant,whatchemicals areleaking,whatarethehealtheffectsofthechemicals andwhatimpactwillthespillhaveontheenvironment?

1000~I'eheardyoudeclaredan"UnusualEvent"earliertoday.~Whatdoesthatsignify--how badaproblemdoyouhave?~Whattimedidithappen?~Howdidtheproblemstart?~Hasanyonebeenkilled?~Arethereanyinjuries?

~Thesituation appearstobegettingworse...is thistrue?5-14

~IworkattheFitzpatrick Plant.~I'mconfusedaboutwhat'sgoingonatGinna...is theleakachemicalorradiological leaktotheatmosphere?

~Hasthe(chemical

/radiation

)leakstopped?~Howmuchwasreleased?

~Doyouneedanyhelpfromus?1015~Whatisthesignificance ofan"ALERT"?~Howseriousaproblemisthat?~Havegovernment officials beencalled?~WhatwilltheGovernordo?~WhatisRGREdoing?~Whattimedidyoudeclarethealert?~Whatconditions causeyoutodeclareanalert?~Didn'tGinnahaveasimilarproblemseveralyearsago?~Ginnaseemstobehavingmore"technical malfunctions" thanotherUSnuclearplants,howdoyouexplainthat?~Isitpoormanagement?

~Isitlowqualityagingequipment?

~HowdoIget"official" information....who's incharge?~WhodoItalktoforgettingmoreinformation aboutradiation beingreleasedfromtheplant?~Arefarmerssupposedtobesheltering livestock?

~I'egotasmalldairyfarminWilliamson andIneedtoknowwhatIshoulddo.~WherewouldIgetmorestoredfeedformycattleifmypasturegetscontaminated?

~IthinkIheardthesirens...do Ineedtoevacuate?

5-15 1030~Iheardthatyoudeclareda"SiteAlert".~Whendidthishappen?~Howmuchoftheplanthasbeendamaged?Isthereisareleaseofradiation?

~Hasanyonebeeninjuredinoraroundtheplant?~lstheplantsafeorinbigtrouble?1100~Whatdoesa"SiteAreaEmergency" mean?Doesn'tthatmeanthatnoonecangoneartheplantforthenextthousandyears?~-Isthisaccidentsimilartotheoneyouhadin1982?~Whydidn'twehavemorewarningaboutthisproblembeforenow?~Whenwillthisproblembeover,ordon'tyouknow?~Willyouevacuatepeoplearoundtheplant?~Insimpleterms,whatareyoudoingtocontrolthisemergency situation?

~Willlotsofradiation bereleased, orhasitalreadystarted?~IsthisasbadasthedisasteratChernobyl?

1115~Arefarmanimalsonpasturegrazingsafe?~Whatabouttheappleorchardsaroundtheplant,howwilltheybeimpacted?

~Areyoureleasing radiation?

~IfsowhataretPelevels?~Arefarmerssupposedtotakeanyactiontoprotecttheirlivestock?

~Whoisthebestsourceoftruthfulinformation onthisemergency?

1130~MyfatherisintheHill-Haven NursingHomeinWebster.~Whatwillhappentohim?~Howlongwillthisemergency last?5-16

~Howdowekeepinformed?

~IsthisasbadasChernobyl?

~Ijustheardonmyscannerthatsomeonefoundevidenceofterrorist

'sabotage onaplantsafetysystem,istheplantgoingtoblowup?1200~Doyouexpectthatanyradiation willbereleased?

~Istheradiation likebombfallout?~Howdangerous isit?~Whoisinchargeoftheemergency?

~Whenwillthenextpressbriefingbeheld?~Whereistheradiation heading?~Whatprotective actionshavebeenrecommended?

~WhomshouldIcallforfurtherinformation concerning theWebsterarea(orOntario)?

~Ifwe'eevacuated, willmyhouseeverbesafetoreturnto?~Wherearepeoplesupposedtogoiftheyevacuate?

1215~WhatistheproblematGinna?~I'mconfused--How didtheproblemstart?~IsthisplantsimilartoChernobyl orTMI?~Canitblowup?~Howmuchradiation isbeingreleasedoffsite?~Whatprotective actionsareineffectforWayne(Monroe)County?~Ifpeoplearoundtheplanthavetoevacuatetheirhomes,whenwilltheybeallowedreturn?5-17

~ThisisfromWRUSRadioinSyracuse.

~HowseriousistheGinnasituation now?~Istheproblemundercontrolyet?Howmanypeoplelivearoundtheplant?~Whatareyougoingtodotofixthesituation?

~Whenisthenextpressbriefing?

~Canweinterview anyoneattheplant?~WhereisyourNewsCenterlocated?~HowdoIgetthere?~Whereisthewindgoing?~Who'sinchargeoftheemergency?

~Weheardthattherewassabotageresulting inbothatoxicchemicalspillandseriousreleaseofradiation, whatcanyoutellusabouthowthiscameabout?1230~IliveinWebsteronSchlegelRoad.I'mworriedaboutleavingmy3dogsbehindifIevacuatemyhome.~CanItakethemalongwithmetoacountyevacuation shelter?~WhatelseshouldItakealongifIgo?~HowmanydaysofpetfoodshouldIbring?~I'mFredAmesfromPerinton.

Iheardthatradiation fromGinnamightblowallthewaydownhere.~WhatshouldIdoaboutmyvineyardandfarm?~Ifmygrapesandlandgetcontaminated, who'sgoingtopaymeformylosses?5-18 1300~ThisisTV25inToronto.IsittruethatyourG-e-e-nareactorissuffering amishapandcanyougiveusanupdateontheseverityoftheproblem?~Briefly,whathappenedthismorningtobeginthisproblem?DoyouAmericans considerthistobeworsethanThreeMileIsland?~Dotheauthorities believethere'schancethatthewindsmaycarryradioactive materialacrossLakeOntariotoCanada?~Canyoutellourviewershowyourreactorisdifferent fromours?~Forexample,willtherebeheavywatercontamination intheLake?~Wealsoheardthattherewasatoxicleakattheplant,whatisyourcomment?5-19 ATTAHMENT2ADMDS.DDSTEDL

~MESSAGEFORINONROECOIONTYTIME0930~CouldyoutellmeabouttheproblematGinna?I'maWebsterresident.

~Isthereachemicaloraradiation problematGinna?~IstheproblematGinnaorNineMileUnitII?~IsGinnaStationshutdownbecauseofanaccidentorsomething?

0945~Ihearthere'sanemergency atthenuclearpowerplant.~Whathappenedandhowbadisit?~I'mofRadioStationWZZE.You'eonour"LIVELINE"andcouldyoutellourlisteners what'shappening attheGinnaNuclearplant?~IstheCountyExecutive goingtodeclareastateofemergency?

~WhatdoestheCountyExecutive intendtorecommend tothepublic?~Arethereanyrecommendations forpeoplelivingwithinafewmilesofGinna?~ShouldCountyresidents takeanykindofproactive measuresbecauseoftheproblemwe'ehearingaboutonthenews?0950~Hasanyradiation orhazardous materialleakedyet?~Howcanyoubesure?Areyoucheckingit?~HowcanIfindoutwhenthereisarelease?~Whoisinchargeoftheemergency?

~Istheplantshutdown?~Istherearelease?~What'shappening atthenuclearplant?5-20 1100~MysonworksatXerox,he'stherenow.~HowwillheknowabouttheGinnaproblem?~Ishesafewhereheis?~DoesRGREhaveanemergency plan?~Ifso,howdoestheCountyfigureinit?~We'elostouremergency information handbookandneedonerightaway.Willoneoftheemergency peopleyouhavedeliveronetous?~IsthereasecurityproblematGinna?~Wastheresabotage?

~Istheplantundercontrol?~Whatdamagewasdone?~Iheardtherewasanexplosion andfireatGinnawhichresultedinbothachemicalreleaseintothelakeandaradioactive cloudbeingreleasedoverWebsterandPenfield, whatisreallyhappening?

1110~Iliveon22113SaltRoadinWebster.Ifthere'sanevacuation, I'mgoingtoneedhelpwithmytwoinfanttwins.Canyouhelpme?~Howmanynuclearplantsareinthearea?~Where'sourpowergoingtocomefromiftheplantisshutdownforawhile?~Haveyouguyscalledforextrahelpwithyourproblem?~Who'srunningtheemergency?

~Whatstationontheradioshouldwebelistening to?~IneedtotalktotheCountyExecutive.

What'shisnumber?Ineedtoknowwhattodo.~IsRGREtellingusthetruth?WeallremembertheIceStormandhowtheyliedthentosavetheirbuttsl5-21

~IliveinPenfield, butIcouldlive50milesawayandwouldn'tfeelsafe...are yougoingtoletusknowifweneedtogetout?~How?1115~Iliveneartheplantandheardthereisan"ALERT",andthenIhearditcalledsomething else...What'sgoingon?~Areyoucheckingtheradiation levelsoutside?~DidSad-AmHussein's peopledothis?~What'sthisIhearaboutafireatGinna?~Wasthatbecauseofabigexplosion orsomething?

~Howmanypeoplegothurtandwho'srunningtheplantnow?~SomebodytoldmetheGinnaworkers"bailout"fromtheplantwhenthere'saproblem.Isthattrue?~IsCuomoorBushsendinghelp?~What'shappening attheGinnaplant?~Istheplantburningoutofcontrol?~Myneighbors aresayingterrorists haveblownuppartoftheGinnaplant.Isthistrue?~HasaStateofEmergency beendeclared?

~Whatshouldthepublicdotoprotectitself?1130~MywifeandIareconcerned becausewehaven'theardthesirensgooff...weliveoverinFairport.

~Shouldn't wehearsirensnow?~Wedon'tthinkyoucountydisasterpeoplearebeingtoldeverything byRGSE.Ican'tevengetastraightansweronmymonthlyelectricbill.What'sreallygoingon?~Idon'ttrustthepowerplantpeople;they'dlietosavetheirownskins.~Doyouhaveanybodycheckingonthem?5-22

~WilltheCountyLegislature lookintothisaccidentandstopGinnafromstartingupagain7~Who'sgoingtopayforalltheclean-upfromthisaccident7

~ShouldIclosemyrestaurant duetotheaccidentatGinnaStation?I'moverinWebsterVillage.~Whatarewesupposedtodo?~WhodoIcalltofindoutifwe'egoingtohavetoleave?~Whowillguardmyplaceifweevacuate7

~I'mcallingfromCalifornia, IhavefamilyinRochester....what's goingonatyourplant?~What'shappening atGinna?1200~IheardthatatGinnaadisgruntled employeesabotaged theplantandthat'swhatcausedthisaccidentf Havetheycaughtthepersonyet7~Hastherebeenaradiation release7~What'shappening toalltheschoolkidsinWebsterSchoolDistrict?

~Iheardthesirenbutnobodysaidwhichwaytogo.Myneighborsaysthesirenmeanstoleaveyourhouseimmediately.

~Isheright7~WhatdoIdo7IliveonDewittRoadneartheElementary School.~IhearthattheMaplewood NursingHomewillkeepitspatientswheretheyare.Mywifeworksthere,butIcan'treachherbecausethephonesarebusy.Willtheybesafethere?1230~I'mleavingnow.WheredoIgofortemporary housing?IliveonStateRoadnearRoute250,~I'rncallingfromPenfield.....has therebeenareleaseofradiation fromGinna7~I'mcallingfromPennsylvania....l live5milesfromGinna.....can wereturnhometomorrow7

~What'shappening atGinna?5-23

~I'mevacuating now.Whichwayissafetotravel7WelivenexttotheWegman'sonHoltRoad.Weneedtemporary housing.I'egot4kidswithme.~Iamsupposedtoleavebutdon'thaveaplacetostay.WhichschoolcanIstayat?IliveonLakeRoadnearRoute250.~HowdoIgetthere?~Who'sgoingtopaymyexpenses7

~WhodoIcalltogetacheckformyexpenses7 1300~Isittruethattheapplesarenowcontaminated?

~Wherearewesupposedtogetourgroceries now?~Wedon'thaveanymoneyoracar.Howdowegetawayfromtheradiation 7~Wheredoweliveandeat?~IliveuponFiveMileLineRoadbyPlankRoad.~IheardtheaccidentattheGinnaStationisgettingworse.~Arewegonnabemovedoutofourhomesafterthis?~Whyhaven'tyoumadetheannouncement onTV?~Areanimalssafetobeleftoutside.WeliveinWebster..~Canweleavethehouse?~HastherebeenanaccidentatGinna7~Whatexactlyhashappened?

~DoesRG8cEhaveaplanforthiskindofthing?~WhatabouttheCounty?5-24 GUMS~DETEDL~ME SAGEFORWAYNECOUNTYTIME0940~Ihearthere'sanemergency atthenuclearpowerplant.~Howseriousistheproblem?~Areschoolsgoingtobedismissed early?~CanIpickupmytwochildrenattheMiddleSchoolinOntario?~I'mofRadioStationWTZ.Canyoutellourlisteners what'happening attheGinnaNuclearplant?You'eliveonour"MORNINGSHOW".~Haveofficials inWayneCountydeclaredastateofemergency?

~WhatisWayneCountydoingtoassistinthisemergency?

~Willyouhaveapressconference?

~HastherebeenaproblemattheGinnaPlant?0950~IlivedownonKnickerbocker neartheOntarioWaterDistrictplant....Have anychemicals orradiation beenreleased, cantheygetintothedrinkingwater?~Istheproblemundercontrol?~Shouldweleaveourhomebecauseofthemishapattheplant?We'everyconcerned aboutthis.~What'stheproblematyourplant?~Whenwilltheemergency beover?~WhatcausedtheproblematGinna?1000~MydaughterandafriendareoutshoppinginOntario.~Howaretheygoingtobewarnedabouttheplantproblem?~WeliveinWalworth...are wesafe?~Areyougoingtoblockofftheroads...my daughterneedstobeabletodrivebackhomel5-25

~What'shappening atthenuclearplant?~IstheproblemI'ebeenhearingaboutatRussellStationorGinna?~Whocausedtheaccident?

~MymotherworksinthelibraryinOntario.~Howdotheyknowthere'sproblem?~Aretheysafe?~Ican'tgetthroughtothelibrary..the lineisbusy.~Whatdoyourecommend Ido?~WeliveinMarion...are wefarenoughaway?~Istheplantundercontrolnow?~Willweloseourpowerbecauseoftheaccident?

~Isthereabrochurewe'esupposedtohavetotelluswhattodo?~Whoisinchargeofyouremergency?

~Isitundercontrol?~I'mcallingfromConsolidated Edison....could yougivemesomeinformation abouttheeventthismorningatGinna?1015~We'elostouremergency information handbookandneedonerightaway.WhichZonedowelivein?~WeliveonSlocumRoadnearKenyonRoad-arewegoingtohavetoevacuate?

We'everyclosetoGinnal~Wherearewesupposedtogoifwe'etoldtoleave?1030~WhathappenedatGinnathismorning?~WhatdoIdoifthesirensblow?~AreallRGSE'splantsunderattack?~Whathappenedthismorning?~WherecanIbuyaradiation instrument tochecktheoutside?5-26 1100~Ihavesomemilkgoatsoutinourfield...out onCountyLineRoadbyBergRoad.WhatdoIdowiththegoats?Bring'eminside?~Weliveinaone-story wood-frame house.ThecalendarwereceivedfromRGREtalksabout"sheltering".

Isn'tthatsupposedtoapplyonlytobrickbuildings withthickwalls?Wedon'tevenhaveabasementl

~IstheGinnaplantrunningnow?~Willyoubeblowingthesirens?~Ifso,whatdowedo?~Ineedtoknowwhat'sgoingonandwhattodo.~Myneighbors arefrightened

....welivetwomileseastoftheplantonFurnaceRoad.~Canwegooutside?Areweindanger?~Areyoupeoplecheckingtheradiation?

~Whatarewesupposedtodowhensirensgooff?1115~Myneighbor's acop....we saysyou'egotasecurityproblem.Howbadisit?~HowmanysecuritypeopleareatGinna?~Haveyoucalledforhelp?~Didthesabotagecausethechemicalrelease?~Didterrorists blowupGinna?~Wereemployees oroutsiders involvedinthedestruction ofsafetyequipment?

~AretheplantsinOswegohavingproblemstoo,orisitjustGinna?~Ifigurewithalltheproblemsrecently, somegroup'ssabotaging allthenukeplantsaroundhere.~Haveyoucapturedthepeopleinvolved?

1130~Wehearthatemergency sheltersareopennow....what dowebringifweneedtostayforawhileandhowmuchwillitcost?5-27

~Howdowegetcheckedforradiation?

Mywholefamilyisfeelingnauseated andweak.~IsWayneCountygoingtobedeclaredadisasterarea?~IsthisaccidentasbadasChernobyl orTMI?~Wheredotheschoolkidsgo?MydaughtergoestoFreewillElementary School.~ShouldIclosemybusinessduetotheaccident?

Whowillpayforthelostincome?(ThebusinessisonRoute104nearCountyLineRoad).1200~AreschoolsclosinginWilliamson...my kidsareattheHighSchool?~Whatarewesupposedtodo-weliveonRoute21inWilliamson?

~WhatshouldIdoformychickenstoprotectthemfromradiation?

~IheardGinnaismeltingdown.IsittruethatStatepeoplearecomingtotakeover?~WeheardtheGovernoriscomingtotakechargeofGinna.~Howwideanareawillbeevacuated

-20,30miles?~HowfarisGinnafromSodus?~ShouldSodusresidents leavetheirhomes?~Isthereaplanfornuclearemergencies?

~Isitfinished?

~Whowrotetheplanandwhoapprovedit?~IsRG5Eresponsible fortheaccidentthathappened?

5-28 j1230~Iheardthesirenbutnowwhatdowedo?WelivejustdowntheroadfromGinna...and Idon'tseeanyoneleavingtheplant....are theyalldead?~Wouldyousendoutthesheriff's department tocheck?~What'shappening attheGinnaplant?~I'mleavingnow.CanIpickmyson?He'sgotajobatAtana'sRestaurant inOntario.~IliveinMacedon...we justhadaproblemafewweeksagowiththedrinkingwater,heavymetalsinthewaterorsomething.

~Arewegoingtohavetoboilourdrinkingwateragainbecauseoftheplant'sradiation?

~Canmypetsbeoutside,cantheydrinkwaterthat'soutside?1300~IthinkIamsupposedtoleavebutdon'thaveaplacetostay.IliveinWayneERPANumber3neartheplant.~WhichcountysheltercanIstayat?~HowdoIgetthere?~Who'sgoingtopaymyexpenses?

~IheardtheaccidentattheGinnaStationisjustafalserumor.What'goingon?~Iliveexactly.6milessouthoftheplant....there's neverbeenaproblembeforeandI'mnotgoingtoleavenow.I'msurethemedia'sjustblowingthisoutofproportion.

~Whyhaven'tyoumadetheannouncement onradio?~Who'sgoingtoguardalltheneighbor's housesaftertheyrunawaytotheshelters?

~IstheGinnaemergency overyet?~IstheGinnareactorshutdown?~Istheplantburning?5-29 1330~WhatistheGinnaproblemthatoccurredthismorning?~I'eheardpeoplearebeingaskedtoleave.Isthattrue?~Werewesupposedtohearthesirens?~WhatradiostationorT.V.channelshouldwehaveon?~WhoisrunningthereactoratGinna?Ihearthesafetyequipment wastamperedwiththismorningbysomeoneintheplant.~Whereistheemergency information inthephonebook.Ican'tfindit.~Whatshouldwetakeifweleaveourhome?~Howdowegettransportation ifwedon'thaveacarandneedtoevacuate?

WeliveonLakesideRoadnearLakeRoad.~IstheaccidentoverwithatGinna?~Who'sgoingtopayforthemessyoucreated?1345~Istherecontamination onthegroundnowfromGinna?~Myhomeowners insurance statesI'mnotcoveredfornuclearaccidentsl WhatdoIdonow?~Whowillcheckmyhomeandpropertytomakesurethere'snoradiation?

WeliveonBostonRoad.~I'mcallingfromBuffalo...l gotmyfamilyoutofourhouseinOntarioCenterthismorning.Whenwillitbesafetogohomeagain?~Canwebecheckedfornuclearradiation somewhere, onourwayhome?~Whocanwegettocheckourfarmpondtoseeifthere'sanycontamination?

~I'egotawellonmyproperty(about6mileseastofGinnaonLakeRoad).Canwestilldrinkfromourwell?~WhocanIcontactifIhavemorequestions, andI'msureIwilli~I'mcallingfromEngland.....what kindofplantisGinna?~Hastherebeenareleasetotheatmosphere?

~Wasthereiodineintherelease?5-30 1400~HowlongwillpeoplewhoevacuatefromWayneERPA1havetostayawayfromhome?~Canhomeowners gobackandchecktheirhomesinthemeantime?

~Whatifthere'safireinoneofourhouses?Areyoujustgoingtoletitburn7~Areresidents supposedtotakepotassium iodide7~Ifwecan'tgetthepotassium, canwetakesalttablets7~Whatishappening atGinna?~Wecaughtsometroutjusteastoftheplantthismorning,around8or9am.~Whatshouldwedowiththefish?~Ismyboatcontaminated nowandamI?5-31 ATTACHMENT PRESSCORPSQUESTIONS

~Howbadaleakoccurred?

~Whatkindofleakwasit-chemicalorradiation?

~Wherediditgo?~Isthereactorstableandundercontrol?~IsthisplantsimilarNineMilePoint?~Wereanyworkersinjuredorcontaminated?

~Howmuchradiation wasreleasedaroundtheplant?~Whatprotective actionsareineffectforWayne(Monroe)County?~HowmanypeopleliveinWayne(Monroe)County?~Whatareyougoingtodotomanagethesituation overthenextseveralhours?~Howlongwilltheemergency beineffect?~Whenisthenextpressbriefing?

~Howmanymediarepresentatives areattheNewsCenter?~WhatagenciesareattheNewsCenter?T~Whereisthewindheadingnow?~Whatistheweatherforecast?

Whateffectwillthathaveonyourrecommendations?

~Who'sinchargeoftheemergency?

~Pleaseexplaintherelationship oftheState,thetwoCountiesandRGSEintermsofhowdecisions aremadeduringthisemergency.

Forexamplewho,makesthedecisiontheactivatethesirens,whodecidestoevacuateorshelter,andhowisthatdecisionreached?Howcanwebesurethatthebestinterests ofthepublicareparamount inthedecisionmakersmind?HowdoestheCountyExecutive andCountyChairmangetthetechnical information theyneedtomakeinformeddecisions?

5-32

~Foranynewsorganization wishingtotakefootageofGinna,whodoweseeattheplantgate?~Howwillhome-bound, mobilityimpairedornursinghomepatientsbeprotected?

~Whatexactlydoes"sheltering" involve..does thisapplytoanytypeofhome?~Whencanpeoplewhohavesheltered, stopsheltering?

~Whendoyouexpecttoenter"Recovery"?

Whatdoesthatmeanexactly?~Willtherebeanyfurtherradioactive releases?

~Willthesirensbesoundedanyfurther?~Howdotouristsknowhowtoprotectthemselves?

~Howistheplantgettingpowernowtorunitssafetysystems?~Willtheshareholders orratepayers absorbthecostofthismishap?~WillGinnaneedtobedecommissioned?

~IsthisthesametypeofproblemthatGinnaexperienced in1982?~Whowillpayforallthedamagetopersonalpropertyfromthisaccident?

5-33

~Aftercleaninguptheradioactive wastefromthisaccident, wheredoesitallgetsent?HasRGREsignificantly addedtotheState'slow-level wastecrisis?~Whydoesn'tRG&Edistribute potassium iodidetothepublic?...do RGREpeoplegetit?~Howclosehaveyoucometoameltdown?

~HowdoyouknowtheextentofdamagetotheGinnareactor?~Whatproblemsdoyouexpectthecontamination willcausewiththeapplefarmsinWayneCounty?~Whateffectwillthereleaseofradioactivity haveonLakeOntariofish?~Whatisthedifference betweengeneticeffectsofradiation andsomaticeffects?~Whatimpactwilltheradiation releasedhaveonunbornbabies?~HowmanycancerdeathsaretherelikelytobeinWayneandMonroecountiesasaresultofthisaccident?

5-34 ATTAHMENT4"SPOUSEPHONE"QUESTIONS 09304Mywifeisasecretary atGinnaStation,andI'eheardthey'ehadanemergency.

Howseriousisit?~Howlongisthisaccidentexpectedtogoon?~Doyouknowifworkershaveevacuated theplant?~Aretheworkersallokay?~CanIpickmywifeup?Ifso,wheredoImeether?0945~ThisisGailBeldue.Myhusband,DickiseitheratGinnaStationorEastAvenuetoday.Ineedtogetamessagetohim.Welive3milesfromtheplantandmayneedtoevacuate.

~Doyouknowforsureifresidents willhavetoevacuate?

~Ifweevacuate, tellDickthatIwillgotomyparentshouse.~TellhimIhopehe'sokay.1015~MyhusbandworksintheGinnaTrainingDepartment.

Ican'treachhimatGinna.HisnameisSamPoulton.~Myneighbortoldmetherewasaproblemwithachemicalaccidentattheplant,andthatthere'sasecurityproblemtoo.Isthattrue?~Haseveryoneevacuated theplant?~Wereanyoftheemployees hurt?~HowcanIreachmyhusband?He'sonbloodpressuremedication.

Ineedtoknowhe'sallright.1045~Myfather,WesleyBackusworksinOperations atGinna.~What'shappening attheplant?~Howbadisit?5-35

~Aretheworkersindanger?Myfatherworksaroundtheback-upsafetyequipment.

~AreGinnaemployees allowedtocallhome?~Ifhecan,haveWesleyBackuscallhomesoIcanstopworrying.

1115~IVly.son-in-law worksatGinnaasaTrainer(JimKnorr).'Wherearetheplantworkersnow...havetheylefttheplant?~Istheplantundercontrolnow?~Howlongwilltheemergency last?1130~Mysistercalledmethismorningandsaidtherewasaproblemattheplant,andsaidshe'dkeepmeposted.Ihaven'theardanythingfromherfor4hours.~ShesaidshemightbesenttosenttoworkintheSurveyCenter.Iseveryonetherenow?~Willtheworkershavetostayattheplant?~IneedtogetthroughtotheTechnical SupportCentertoaskherwhatarrangements Ishouldmakeconcerning herkidsatdaycare...since I'matwork.HernameisBarbButler.1200~MyfatherworksatGinna,andistherenow,HeworksintheTrainingCenter(JimHuff).~Hastherebeenarelease?~Dotheyhavetheplantsaboteuridentified yet?~CanIdrivetotheplantanddropoffsomesandwiches formyfatherifhe'sgottostayovernight?

5-36 SECTION6.0SCHEDULEOFEVENTS ECION192INNAPLUIVIEEXPOSUREPATHWAYEXERIESCHEDLEFEVENTDATETIMEPERONNELRP~ATIVITY10/59-11ALL(EOF)PLAYERBRIEFING2-4ALL(TSC)PLAYERBRIEFING10/78-12ASASSIGNEDCONTROLLER BRIEFING1-4NRCTEAIVlNRCTEAM,BADGING5BRIEFING10/810/98-10ALLCONTROLLERS 1992EXERCISEPRE<RITIQUE MEETING10-11OPENRGSECORPORATE CRITIQUE11-12OPEN~CRmQUE6-1 SECTION7.0EXERCISESCENARIO GINNASTATION1992EMERGENCY PREPAREDNESS EXERCISEINITIALCONDITIONS 1.TheR.E.GinnaNuclearPowerPlantisoperating atapproximately 97%ratedthermalpower.ThePlanthasbeenoperating atthispowerlevelcontinuously forapproximately 150days.2.The"A"SteamGenerator (S/G)primarytosecondary leakrateincreased approximately 5daysagotoacalculated 60cc/min.

Atapproximately 0630hoursthismorningtheprimarytosecondary leakratehasagainincreased significantly asindicated byasubstantial increaseinradiation monitorR-15(AirEjector).

Radiation monitorR-19(S/GBlowdown) hasalsoindicated anincreaseinactivity.

TheHealthPhysics/Chemistry Department isintheprocessofanalyzing samplestodetermine thecalculated leakrate.3.Equilibrium PrimaryCoolantIsotopicactivityasof0300hours(10/8/92isprovidedintable9.2ofscenarioSection9.3.Totalactivityis2.56microcuries/gram.

Chemistry LogSheet,available fromtheController.

4.TheReactorCoolantSystem(RCS)totalleakageis0.361GPMasof0400hoursthismorningandhasbeenincreasing.

identified RCSLeakageis0.073GPM.5.Generalweatherconditions arepartlycloudywithnocurrentprecipitation.

ForpurposesoftheExercise, additional meteorological information intheSimulator ControlRoomshouldbeobtainedfromthePlantProcessComputerSystem(PPCS).6.ThePrimaryWaterTreatment Plantissecuredformajormaintenance thatwilltakeapproximately 3days.the100,000GallonOutsideCondensate StorageTankisat20%Level.ADemineralizer Trailerhasbeenorderedandisscheduled toarriveat1300hourstoday.7.TheHouseHeatingBoilerisinserviceandNuclearSteamissecuredandheld.7-2 GINNASTATION1992EMERGENCY PREPAREDNESS EXERCISEONSITESEQUENCEOFEVENTSAPPROPRIATE SCENARIOTIMETIMEEVENTDESCRIPTION 070007150730IJNUSUALEVENT-00/1500/0000/15InitialConditions established Announcement toCommenceAnnualEmergency ExerciseTheHealthPhysics/Chemistry Department informstheControlRoomthatthe"A"S/Gcalculated leakrateisapproximately 450cc/min (i.e.,~0.125gpm).ANTICIPATED RESULTContrIRomOperators shouldbeginperforming theapplicable actionsofOperating Procedure 0-.6.10(PlantOperations withSteamGenerator TubeLeakIndication).

q,g~/g-Z.I)AnorderlyPlantshutdownshouldcommencetobeinHotShutdownwithin6hoursandtobelessthan350'FintheRCSwithinthenext6hoursasrequiredbyPlantTechnical Specification.

A~UIhIdhdIdfdIhE~PI1-0,~GinnaStationEventEvaluation andClassification,"

EAL:SteamGenerator TubeRupture(SGTR);SteamGenerator TubeLeakage).1GPMasidentified bysampling.

Appropriate offsitenotifications shouldbemadeperEPIP1~5.If~UIEdIdfpp*IIffdminutes,acontingency messageshouldbegivenouttodeclareit.7-3 APPROPRIATE SCENARIOTIME.TIMEEVENTDERIPTIN075500/40The"A"S/GARVpopsopenandcannotbeclosedfromtheControlRoom.ANTIIPATEDRESLT~R'RShouldsendanAuxiliary OperatortotheSteamHeaderAreatoclosetheIsolation Valveonthe"A"S/GARV.Operators performing theapplicable actionsof0-2.1.TchnicISuorCnr081000/55ThePlantManager,Operations Assessment Manager,andDutyEngineershouldbemanningtheTSCforOffsiteCommunications Assistance perEPIP1-5.TheAuxiliary Operatorsenttoisolatethe"A"S/GARVreportstotheControlRoomthattheLA-"-S/GARVisLisolated,abut hehasnoticedatsteam-leak onthe"B"S/Gt'ARV,betweentheARV-andtheARVIsolation-Valve.--l ANTICIPATED RESULTSConrIRomShouldinformpeoplemanningtheTSCofthe"8"S/6ARVLinesteamleak.MayrequestAuxiliary Operatortoisolatethe"B"S/GARV.Operators performing theapplicable actionsof0-2.1.ShouldinformthepeoplemanningtheTSCofthe"A"S/GARVproblemandisolation.

7-4 APPROPRIATE SCENARIOTIMETIMEEVENTDESRIPTIONThniInr0815Mayrequestthatthe"B"S/GARVbeisolatedormaywaituntilMaintenance personnel haveinspected it.MayinformControlRoomthattheywilltakeactionstohaveMaintenance personnel inspectforthe"A"And"B"S/GARVproblems.

01/00Annunciator G-22(ADFCSSystemTrouble)alarms.ANTICIPATED RESULTnrolRoomOperators performtheapplicable actionsofAR-G.22.Operators shouldchecktheS/Glevelstoensureproperlevelcontrol.0840Operators shouldinformthepeoplemanningtheTSCandI5CDepartment oftheADFCSproblem.01/25TheCCWSurgeTankLoLevelAlarm(AR-A-13) annunciates andtheCCWlevelindicates itisdecreasing.

ANTICIPATED RESULTS~R'ROperators performtheapplicable actionsofAlarmResponseProcedure AR-A-13(CCWSurgeTankLoLevel41.2%).Operators shouldsendanAuxiliary OperatorintotheAuxiliary BuildingtoidentifytheCCWLeak.ShouldinformthepeoplemanningtheTSCoftheCCWleak.7-5 APPROPRIATE SCENARIOTIMETIMEEVENTDERIPTIN085001/35Auxiliary OperatorcheckingtheCCWleakinAuxiliary BuildinginformsControlRoomthatthe1ACCWPumpMechanical Sealisleakingandsprayingonthepumpmotor.Therunning1ACCWPumptripsoutonovercurrent andannunciator (AR-A-17) alarms.Thestandby1BCCW'umpstartsautomatically anddeliverers requiredflow.ANTICIPATED RELTConrolRoomOperators performtheapplicable actionsofabnormalprocedure AP-CCW.2(LossofCCWduringpoweroperation).

Operators requesttheAuxiliary OperatorsenttoidentifytheCCWleakintheAuxiliary

Building, toisolatethesuctionanddischarge ofthe1ACCWPumpandrackoutitselectrical breaker.085501/40Operators shouldinformthepeoplemanningtheTSCofthe1ACCWPumpproblems.

TheADFCSproblemwiththeMFWRegulating Valvesisrepaired..

ANTICIPATED RESULTSCnrolRom090501/45Operators continueshuttingPlantdownper0-2.1Auxiliary Operatorisolating the1ACCWPumpinformsControlRoomthattheSuctionandDischarge Valvesareclosedandtheelectrical breakerisrackedout.ANTICIPATED RESULTSnrlRmOperators shouldensurethat1ACCWPumpControlSwitchisinpullstopandCCWSurgeTanklevelhasreturnedtonormal.7-6 APPROPRIATE SCENARIOTIIVIETIMEEVENTDESRIPTIN091502/00Thefollowing eventsoccursimultaneously:

ALERT~Pressurizer levelandpressuredecreases uncontrollably.

~Areactortripoccursautomatically fromlowpressurizer pressuregrismanuallyactivated bytheoperator.

~Asafetyinjection occursautomatically fromlowpressurizer pressuregrismanuallyactivated bytheoperator.

~The"A"S/Gwaterlevelincreases uncontrollably.

~Allsafeguards equipment requiredisoperating.

ANTICIPATED RESULTSCnrIRomOperators performing theimmediate actionsofE-0(Reactortriporsafetyinjection).

~'l<)PAnALERTshouldbedeclaredinaccordance withEPIP1-0,"GinnaStationEventEvaluation andClassification,"

EAL:SteamGenerator TubeRupture(SGTR):SGTR)100GPM.Appropriate onsiteandoffsitenotifications shouldbemadeperEPIP1-5~IfandALERTisnotdeclaredinapproximately 15minutes,acontingency messageshouldbegivenouttodeclareit.Operators transition toE-3(SteamGenerator TubeRupture)andstartperforming.its applicable actions.7-7 APPROPRIATE SCENARIOTIMETIMEEVENTDECRIPTION094502/30AccidentResponseandEvaluation continues.

ANTICIPATED REULT~RIROperators performing theapplicable actionsofE-3(SteamGenerator TubeRupture)tostabilize thePlant.TechnialSCenrTheTSCshouldbenearingoperational readiness oftheEmergency ResponseOrganization.

TheTSC,whenoperational, shouldsendrepairteamsintotheAuxiliary Buildingtoevaluatethe1ACCWPumpandmotorproblems.

TheTSC,whenoperational shouldsendrepairteamsouttoevaluatethe"A"and"B"S/GARVproblemsifnotalreadydone.Emernc0erinFiliJENCEOFmaybeactivating atthistimeduetoPlantconditions.

JENCwillbeactivating atthistime,100002/45Accidentresponseandevaluation continues andDItruckarrivesatsite.ANTICIPATED RESULTSnrIRomOperators performing theapplicable actionsofE-3(SteamGenerator TubeRupture)tostabilize thePlant.Technical SuorCenerTheTSCshouldbeassumingcommandandcontrol.7-8.

APPROPRIATE SCENARIOTIIVIETIMEEVENTDERIPTIN101503/00Annunciator J-9(Safeguard BreakerTrip)Alarms.ANTICIPATED RELTontrolRomWhenoperators checktheBoard,the"A"SWPumpSwitchindicates awhitedisagreement lightandthe"A"SWPumpindicates tripped.1030SITEAREAEMERGENY03/15Operators/TSC shouldsendanAuxiliary OperatortotheScreenHousetocheckon"A"'SWpump.Operators shouldinformtheTSCofthe"A"SWPumpproblem.TheAuxiliary OperatorsenttotheScreenHousetocheckthe"A"SWPumpreportstotheControlRoom/TSCthathecanfindnothingwrongwiththe"A"SWPumpbuthehassmelledthestrongodorofgasthrough-out thebuildingwiththestrongest odorintheBasement.

ANTIIPATEDRESLTSConrolRoomShouldrequestthattheAuxiliary OperatorfindtheshutoffvalvesforthenaturalgasandpropanegastotheScreenHouseandclosethem.ShouldinformtheTSCofthegasproblemintheScreenHouse.Ifnotalreadyisolated, shouldsendanAxiliaryOperatortoisolatethe"B"S/GARVwhenrequested todo.TehnicIuonrTheTSC,afterassessing Plantconditions, should:7-9 APPROPRIATE SCENARIOTIMETIMEEVENTDERIPTINDeclareaSITEAREAEMERENYinaccordance withEPIP1-0,"GinnaStationEventEvaluation andClassification,"

EAL:Hazardsbeingexperienced orprojected; entryofuncontrolled flammable gasesintovitalareas.Appropriate notifications ofoffsiteagenciesshouldbemadeperEPIP1-5.IfaSiteAreaEmergency isnotdeclaredinapproximately 15minutes,acontingency messageshouldbegiventodeclareit.TSCshouldinformtheEOFofPlantconditions andtheSiteAreaEmergency Declaration.

ASiteEvacuation shouldbecommenced ifitisdetermined necessary.

ReairTeamsRepairteamsentouttochecktheCCWPumpshouldreportthatthe1ACCWPumpMechanical sealneedsreplacing andthatthe1ACCWPumpmotorneedstobecleanedanddried.Theyreportthiswilltakeapproximately 8hours.Theyalsoreportthatthe1BCCWPumpMechanical Sealisleakingasmallamount.RepairTeamsentouttocheckthe"A"S/GARVcontrolproblemshouldreportthattheARV'sMercoidcontroller needstobereplaced.

Theyreportthatitwilltakeapproximately 1hourtodo.104503/30Ifnotdoneearlier,theRepairTeamsentouttocheckthe"8"S/GARVSteamleakrequestthatitbeisolated.

Accidentresponseandevaluation continues.

Ifnotdoneearlier,theAuxiliary operatorsentouttoisolatethe"B"S/GARVsteamleakreportsbackthatitisisolated.

7-10 APPROPRIATE SCENARIOTIMETIMEEVENTDESCRIPTI NANTICIPATED RESULTonroiRoomOperators performing theactionsofE-3(SteamGenerator TubRupture)shouldhavestabilized thePlantatapproximately thistimeandbeawaitingdetermination bytheTSCastowhatpostSGTRcooldownprocedure touse.Ifnotdoneearlier,shouldinformtheTSCofthe"B"S/GARVsteamleakisolation.

ThniaISrnrTheTSCshouldbeevaluating theflammable gasproblemintheScreenHouseandbetakingcorrective actionsrequiredtoreturntheScreenHousetoasafecondition (i.e.,sendingaFireandSafetyTeamtoevaluateandcorrect).

TSCDoseAssessment performing offsitedosecalculations asnecessary.

TSCshouldinformCRtouseES-3.1(POST-SGTR Cooldownusingbackfill).

RairTeamsRepairTeamsentouttocheckthe"B"S/GARVsteamleakreportsthatitappearsthatthesteamleakwasfroma0.5-inchholedrilledalmostthroughthepipe,andalsothataflangeisleaking.Theyreportthatitwilltakeapproximately oneandahalfhourstorepairtheleak.7-11 APPROPRIATE SCENARIOTIMETIMEEVENTDESCRIPTI N110003/45Condensate StorageTank(CST)levelsdecreaseto5feet.ANTIIPATEDRELTonrolRomOperators shouldrefertoER-AFW.1(Alternate WaterSupplytoAFWPumps)perfoldoutpageofES-3.1,Statement 4,whichstates,"IfCSTleveldecreases tolessthan5feet,~hnswitchtoalternate AFWsupply(RefertoER-AFW.1, Alternate WaterSupplytoAFWPumps)andperformapplicable actions.ShouldinformTSCofthelowlevelintheCSTs.TECHNICAL SUPPRTCENTERTSCevaluating Plantconditions andtakingactionwhererequired.

TSCshouldinformsecurityoftheasfoundcondition ofthe"B"S/GARVsteamleak.TSCDoseAssessment performing offsitedosecalculations asrequired.

TSCshouldbeexpediting therepairoftheS/GARVsbecauseoftheiruseduringsucheventsaslossofcondenser andPlantcooldown.

TSCshouldsendaRepairTeamtocheckoutthe"A"SWPumpproblemwhentheScreenHouseisdeclaredsafeforentry.TSCshouldinformEOFofPlantstatusandproblems.

~S~uriyShouldbeevaluating thedrilledholeinthe"B"S/GARVpipe.Emerenc0eraionFciliTheEOF,afteritismanned,shouldstartassessing Plantconditions andtakeactionasrequired.

7-12 APPROPRIATE SCENARIOTIMETIMEEVENTDESCRIPTION 111504/00Dltruckstartspumpingtooutsidestoragetank.112004/05The"A"S/GARVMercoidisrepairedandreadyforreturntoservice.ANTICIPATED RELTSnrIRomOperators performing applicable actionsofES-3.1(Post-SGTRCooldownusingBackfill).

Operators performing applicable actionsER-AFW.1.

Operators shouldreturnthe"A"S/GARVtoserviceifrequested bytheTSC.TchniISCnterTSCevaluating Plantconditions andtakingactionswhererequired.

TSCDoseAssessment performing offsitedosecalculations asrequired.

TSCmayrequesttheControlRoomtoreturnthe"A"S/GARVtoservice.~SecuriShouldbeevaluating thedrilledholeinthe"B"S/GARVpipe.EmrencrionFciliTheEOF,afteritismanned,shouldstartassessing Plantconditions andtakeactionasrequired.

EOFDoseAssessment shouldbeperforming offsiteDoseAssessment, asrequired, inparallelwiththeTSCDoseAssessment.

TheEOFshouldbeassumingcommanded andcontrolatapproximately thistime.7-13 APPROPRIATE SCENARIOTIMETIMEEVENTDESRIPTINRirTPerforming actionsasrequiredtoreturnequipment toserviceassoonaspossible.

114504/30Accidentevaluation andresponsecontinues.

Anindividual arrivesattheTSCandduringfrisking, findscontamination onhisshoesandclothing.

,TheRochester Telephone Corp.telephones intheEOFaresuddenlyfoundtobeinoperable.

ANTICIPATED RESULTS~R'ROperators shouldbeperforming theapplicable actionsoftheES-3.1(Post-SGTR CooldownusingBackfill).

TchnicIoCnerTSCevaluating Plantconditions andtakingactionasrequired.

EOFevaluating Plantconditions andtakingactionasrequired.

TSCshouldrequestControlRoomtoreturnthe"B"S/GARVtoservice.HealthPhysicstechnicians respondtothecontaminated individual attheTSCentrance, performfurthercontamination monitoring, securetheTSCentranceandinitiateappropriate decontamination andfollow-up actions.Emrenc0erionFailitEOFpersonnel investigate natureoftelephone systemfailure,andswitchtoalternate telephones forvoiceandfaxcommunications.

7-14 APPROPRIATE SCENARIOTIMETIMEEVENTDESRIPTION~1230M05/15Recover/Re-entry discussions shouldcommence.

Thisshouldincludepreliminary discussions aboutshorttermandintermediate termconcerns, including preliminary designation oftheRecoveryOrganization.

Statearidcountiesmayalsoconductparalleldiscussions.

Recovery/Re-entry interface betweenTSC/EOFandoffsiteagenciesshouldbedemonstrated astimeallows.~1315~06/00AfterallExerciseObjectives havebeendemonstrated, theExercisewillbeterminated.

7-15 U

TABLE7.1SIMULATOR SET-UPDATAFOREXERCISESCENARIO RITIALIMLATRET-PDATAFR12MEENYPLANNINIMLATR1.AtQQQEquipment Set-up-See0700PlantStatussheet.2.AtQ7QQReactorCoreisinIVIOL(571PPMBoron).3.AtQ7QQRCSLeakRateis0.361GPM.4.AtQ7QQ"A"S/GPrimarytoSecondary LeakRateisapproximately 450cc/min (0.125gpm).5.Atg)~7R-15onAlarmandReadingapproximately 4.6x10'pm.6.AtQ7QQHP/Chemistry ReportstotheControlRoomthatthe"A"S/Gcalculated primarytosecondary LeakRateis450cc/min (i.e.,0.125GPM).7.At~Q7MOperators startshuttingthePlantdowninaccordance withthe0-6.10and0-2.1at10%/hrfor2hoursandthenat20%/hrfortherestoftheshutdown.

8.AIL7&~IEhIdbdId,IRG<<TbLeakage>0.1GPIVIasidentified bysampling).

9.AtQ7~the"A"S/GARVpopsfullopenandcannotbeclosedfromtheControlRoom.10.AtQ5~1the"A"S/GARVIsolation Valveisclosed.11.AtQQ~the"B"S/GARVisreportedtohaveasteamleak.~N:Isolation ofthe"B"S/GARVcanoccuratanytimefromnowon.12.AtQ9~1Annunciator G-22(ADFCSSystemTrouble)Alarms.13.AtQgggCCWSystemleakof20GPIVlstarts.14.AtQg~theCCWSurgeTankLoLevelAlarm(A-13)annunciates andtheCCWlevelindicates itisdecreasing.

15.AtQQ~theADFCSProblemisRepaired.

16.At93~the1ACCWPumpSuctionandDischarge Valvesareclosedisolating theleak.TheElectrical Breakerisrackedoutalso.17.AtQ91'jthe"A"S/Gsustainsatuberuptureofapproximately 700GPM.7-/7 ALIMLATRET-PAFEMERENYPLANNINIMLATRRN(continued) 18.At~9939,analertshouldbedeclared.

(S/GTuberupture>100GPM)19.At~1QQ,DltruckarrivesonSite.20.AtQQ1the"A"SWPumptripsout-Annunciator (J-9)alarms.21.At~1',anaturalgasleakintheScreenHouseisreportedbyAuxiliary Operatorsentouttocheckthe"A"SWPump.22.At1/1)OutsideStorageTankEmptyasReportedbyAuxiliary Operator.

23.At~~1~4aiArEmrnshouldbedeclared(entryofuncontrolled flammable gasesintovitalareas).~24,At11QQ,theCSTlevelsdecreasebelow5feet.26.At~111MobileDltruckstartspumpingwatertoDST26.At112ltthe"A"S/GARVMercoidisrepaired.

27.At~I14the"B"S/GARVsteamleakisrepaired.

28.At~~1~1theExerciseisterminated.

TABLE7,2SIMULATOR SET-UPDATAFOREXERCISESCENARIORADIOLOGICAL ANDMETEOROLOGICAL DATA 92EX.XLS0SPEED33DIR33TEMP33SPEED150DIR150TEMP150DT150-33SPEED250DIR250TEMP250DELTATEMP7'003.720952.94.717453.30.46.118855.42.57:153.819352.94.818453.30.47.2~18855.52.67:303.6202534.517453.40.47.115855.52.57:453.821553.54.820153.57.215855.62.18:003.622257.74.720257.90.27.1168580.38:153.619458.74.517458.1-0.67.115858-0.78:302.64759.63.76558.8-0.83.56458.9-0.78:453.87959.88559.4-0.47.77959-0.89:003.15259.95.25559.99.55759.3-0.69:153.85060.74.95260.77.55460.7R02R04R07R09R15R19R34R31R32R15A5R15A6R15A7R15A96.40E+006.40E+006.40E+004.40E+004.40E+004.40E+006.40E+006.40E+006.40E+003.40E+013.40E+013.40E+014.66E+048.75E+041.25E+054.07E+034.07E+034.07E+039.90E-019.90E-019.90E-011.02E-021.02E-021.02E-021.01E-021.01E-021.01E-022.33E-03440E-036.29E-034.32E-024.32E-024.32E-022.33E-03440E-036.29E-032.33E-034.40E-036.29E-036.40E+004.40E+006.40E+003.40E+011.25E+054.07E+039.90E-011.02E-021.01E-026.29E-034.32E-026.29E-036.29E-036.40E+006.40E+004.40E+004.40E+006.40E+006.40E+003.40E+013.40E+011.25E+051.25E+054.07E+034.07E+039.90E-019.90E-011.02E-021.02E-021.01E-021.01E-026.29E-036.29E-034.32E-024.32E-026.29E-036.29E-036.29E-036.29E-036.40E+004.40E+006.40E+003.40E+011.25E+054.07E+039.90E-011.02E-021.01E-026.29E-034.32E-026.29E-036.29E-03.6.40E+006.40E+006.40E+004.40E+004.40E+002.30E+016.40E+006.40E+006.40E+003.40E+013.40E+011.48E+021.25E+051.25E+059.99E+064.07E+034.07E+031.57E+049.90E-019.90E-019.00E-011.02E-021.02E-023.02E+001.01E-021.01E-021.01E-026.29E-036.29E-039.99E434.32E-024.32E-028.00E-016.29E-036.29E-031.85E+006.29E-036.29E-031.85E+00JOT,5LOA=LOScymav6V'LOS=lV1cpm4cV<1fQag.Page1 92.XLSTIMESPEED33DIR33TEMP33SPEED150DIR150TEMP150DT150-33SPEED250DIR250TEMP250DELTATEMP9:359'454.94961.34.855620.76.95461.39:5510:005561.35.26162.51.26.16961.40.110:154.98061.34.872620.76.67763.310:304.88061.37.98662.20.97.889631.710:455.27961.45.57962.55.17763.52.111:004.87962.42.87963.30.95.17764.92.511:158062.55.18162.56.8692.411:305.67962.77963.91.26.5782.1R02R04R07R09R15R19R34R31R32R15A5R15A6R15A7R15A97.35E+002.30E+017.35E+001.48E+024.41E+069.00E-019.99E-032.00E-012.20E-012.20E-017.35E+007.35E+007.35E+002.30E+012.30E+012.30E+017.35E+007.35E+007.35E+001.48E+021.48E+021.48E+024.41E+061.58E+031.58E+031.57E+041.57E+041.57E+049.00E-019.00E-019.00E-013.02E+003.02E+003.02E+001.01E-021.01E-021.01E-029.99E-032.09E-072.09E-072.00E-012.00E-012.00E-012.20E-011.30E-051.30E-052.20E-011.27E-031.27E-037.35E+002.25E+017.35E+001.46E+021.58E+031.52E+049.00E-012.90E+001.01E-022.09E-072.00E-011.30E-051.27E-037.35E+007.35E+002.18E+012.13E+017.35E+007.35E+001.43E+021.41E+021.58E+031.58E+031.47E+041.42E+049.00E-019.00E-012.85E+002.72E+001.01E-021.01E-022.09E-072.09E-072.00E-012.00E-011.30E-051.30E-051.27E-031.27E-037.35E+007.35E+002.07E+012.01E+017.35E+007.35E+001.38E+021.36E+021.58E+031.58E+031.38E+041.32E+049.00E-019.00E-012.68E+002.50E+001.01E-021.01E-022.09E-072.09E-072.00E-012.00E-011.30E-051.30E-051.27E-031.27E-037.35E+001.95E+017.35E+001.34E+021.58E+031.28E+049.00E-012.50E+001.01E-022.09E-072.00E-011.30E-051.27E-03Page2 92.LSTIMESPEED33DIR33TEMP33SPEED150DIR150TEMP150DT150-33SPEED250DIR250TEMP250DELTATEMP11:456.276656.67765.30.37.27066.81.812:006.17765.16.57865.30.27166.81.712:156.577666.77966.30.37.47967.81.812:308.567697.76966.3-2.77.46967.8-1.212:458.765667.96266.30.37.96667.81.81:001:151:301:452:00R02R04R07R09R15R19R34R31R32R15A5R15A6R15A7R15A97.35E+001.89E+017.35E+001.32E+021.58E+031.28E+049.00E-012.42E+001.01E-022.09E-072.00E-011.30E-051.27E-037.35E+001.84E+017.35E+001.29E+021.58E+031.19E+049.00E-012.33E+001.01E-022.09E-072.00E-011.30E-051.27E-037.35E+007.35E+007.35E+001.78E+011.72E+011.65E+017.35E+007.35E+007.35E+001.27E+021.24E+021.22E+021.58E+031.58E+031.58E+031.14E+041.09E+041.02E+049.00E-019.00E-019.00E-012.25E+002.18E+002.16E+001.01E-021.01E-021.01E-022.09E-072.09E-072.09E-072.00E-012.00E-012.00E-011.30E-051.30E-051.30E-051.27E-031.27E-031.27E-037.35E+001.60E+017.35E+001.20E+021.58E+039.90E+039.00E-011.93E+001.01E-022.09E-072.00E-011.30E-051.27E-03'.35E+007.35E+007.35E+007.35E+007.35E+007.35E+001.58E+031.58E+031.58E+031.50E+041.50E+041.50E+049.00E-019.00E-019.00E-011.87E+001.01E-021.01E-021.01E-022.09E-072.09E-072.09E-072.00E-012.00E-012.00E-011.30E-051.30E-051.30E-051.27E-031.27E-031.27E-037.35E+007.35E+001.58E+031.50E+049.00E-011.01E-022.09E-072.00E-011.30E-051.27E-03Page3 TABLE7.3SIMULATOR USEGUIDELINES 7-23 TABLE7.IMLATRPREPARATI NANDEIDELINE2DaysPriorTestFaxCheckbatteries inheadsetsTSCSimLead1DayPriorCheckEPIPAttachment SupplyinProcedure CabinetRadiosforSim(5)SimLeadSimLead/CNEP ExerciseDayTurnoverTransferREGS,NRCphonesTransferpageCheckPPCSprinter(ON)DisableloaddispatchphoneSwitchoverPPCS/SASperEPIP5-5788PrefixLoaddispatch¹SimOOCEquipment Operations Supervisor

/PresentOperations Manager*/PresentHP/STAlocationfornotification SimLeadSimLeadSimLeadSimLeadTSCSimLeadSimLeadSimLeadSimLeadSimLeadSimLeadAfterChainofcustodyofradiosSwitchbackPPCS/SASperEPIP5-5TransferREGS,NRCphonesTransferpageEnableloaddispatcher phoneSimLead/CNEP TSCSimLeadSimLeadSimLead SYSTEMPRESSURES ReactorCoolantSystem&SteamGenerator PSIG25002000150010005000111111.1111111899999900001111222234013234013401340134050500050505050505050CLOCKTIMERCS~1AS/G~1BS/G LEVELINDICATION TRENDSPRESSURIZER, S/8,RVLIS(%)1008060402001888899999900134011234005050570050CLOCK11111111110001111222I13401340135050505050TIMEPRESSURIZER

~1AS/GLEVEL~18S/GLEVEL~RVLIS TANKLEVELTRENDSBAST,RWST(%)10080604Q20088880134050511999999000112340105700505CLOCKTIME1100305111111I0130501112Q50BAST~RWST SECTION8.0MESSAGEFORMSANDPLANTDATASHEETS MESSAGEINDEXTIME0700071507300745075007550755075508000810081508150815083008400840084508500850085008550900090509150917092009300930094510001000101510151030MEAENO.I.C..12.3.4X.5.6.7.8.9.10.11.12.13.14.15.16.1718.19.20.21.22.23.24.25.26.27X.28.28.1293031.32.MESAGEInitialConditions Established Announcement toCommenceAnnualExposureExerciseNotification of"A"S/GLeakRateof450cc/min PlantStatusUnusualEventContingency Message"A"S/GARVPoppingOpenMini-Scenario for"A"S/GARVIsolation and"B"S/GARVLeakDetection

",A"S/GARVMercoidControlProblemMini-ScenarioPlantStatus"B"S/GARVIsolation PlantStatus8cADFCSTrouble"B"S/GARVLineSteamLeakMini-Scenario MFWRegulating Valves(ADFCS)TroubleMini-ScenarioPlantStatusCCWSurgeTankLoLevelAlarm1ACCWPumpLeakDetection andIsolation Mini-ScenarioPlantStatus1ACCWPumpTrip1ACCWPumpMechanical SealFailureMini-Scenario1A'CWPumpMotorProblemFromPumpSealFailureMini-Scenario ADFCSProblemRepairedPlantStatus1ACCWPumpIsolatedPlantStatus5SGTRin"A"S/GPlantStatusPlantStatusPlantStatusAlertContingency MessagePlantStatusMobileDlTruckMini-Scenario PlantStatusandMobileDlTruckArrivesonSitePlantStatusand"A"SWPumpTrip"A"SWPumpInspection Mini-Scenario NaturalGasLeakDetection andIsolation Mini-MESSAGEINDEX(continued)

TIME~MEDEAEED.IVIESAGE103010451045104511001100110011151120112011301145114511451145114512001215123012451300131533.34.35.36X.37.383940.41.42.43.44.45.46.46.146.247.48.49.50.51.52.PlantStatusPlantStatusAirEvacuation ofScreenHouseMini-Scenario SiteAreaEmergency Contingency MessagePlantStatus"A"SWPumpProblemMini-Scenario SecurityInvestigation of"B"S/GARVDrilledHoleMini-Scenario PlantStatusandMobileDlTruckStartsPumpingtoOST."A"S/GARVMercoidRepairCompleteMini-Scenario for"A"S/GARVReturntoServicePlantStatusThe"B"S/GARVSteamLeakRepairCompleted "B"S/GReturntoServiceMini-Scenario PlantStatusMini-Scenario forEOFTelephone SystemFailureMini-Scenario forContaminated IndividualArriving atTSCPlantStatusPlantStatusPlantStatusPlantStatusPlantStatusPlantStatusandTermination ofExercise MINI-SCENARIOS 1."A"S/GARVMercoidControlProblem~7tlIB2."A"S/GARVIsolation 7HrAxilirrar3."B"S/GARVLeakDetection 0810HorsAxiliar0eraor4."B"S/GARVIsolation 1HrAxiliar0eraor5."B"S/GARVSteamLeakRepair81HrnPifirnWlr6.ADFCSTrouble~IH1a7.1ACCWPumpLeakInspection andIsolation 4urAuxiliarrr8.1ACCWPumpMechanical SealFailure5HorMhanics9.1ACCWPumpMotorProblemfromPumpSealFailure0850HourElecricians10.MobileDlTruckonSite,HookupandStartPumping,1000Auxiliar0eraorSecuriandChemis11.1AServiceWaterPumpProblemInspection 11HrAxiiir0eraor12.NaturalGasLeakDetection inScreenHouse10HrAxiliar0eror13.NaturalGasandPropaneGasIsolation toScreenHouse1HorAxiliar0eraor14.AirEvacuation ofScreenHouseAirtoRemoveNaturalGasConcentration 1045HourFireAndSafe

15.SecurityInvestigation ofthe"B"S/GDrilledHoleSteamLeak11Hreri16.17.1AServiceWaterPumpProblem(Breaker) 11rElriin"A"S/GARVReturntoService1120orAxiliar0eraor18."B"S/GARVReturntoService1145HrAxiiir0raor19.Telephone SystemFailureinEOF114HrEFff20.Contaminated Individual ArrivesatTSC114HurHealhPhsis NTROLLERS FRMINI-SCENARI A.XLIARYPEATRNTRLLER1.2.3.4.5.6.7.8.9.10.QBM1QBM1Q)441000~1~1F39.MIBQ~112~114"A"S/GARVIsolation "B"S/GLeakDetection "B"S/GIsolation 1ACCWPumpLeakInspection andIsolation MobileDITruckOperation 1ASWPumpProblemInspection NaturalGasLeakDetection inScreenHouseNaturalGasandPropaneGasIsolation toScreenHouse"A"S/GARVReturntoService"B"S/GARVReturntoServiceB.MEHANICONTROLLER

%88Q.1ACCWPumpMechanical SealFailureTRICIANS'.~ELE1.2,08gg~1101ACCWPumpMotorProblemfromPumpSealFailure1AServiceWaterPumpProblem(Breaker)

D.PIPEFITTER ANDWELDERSCONTROLLER 815"B"S/GARVSteamLeakE.I5CCONTRLLERS1.2.Q75508'I5"A"S/GARVMercoidControlProblemADFCSTroubleF.FIREANDAFETYCNTROLLER1045AirEvacuation ofScreenhouseAirtoRemoveNaturalGasConcentration G.ERITYNTRLLER1.11QQInvestigation ofthe"B"S/GDrilledHoleSteamLeak2.1000EscortMobileDlTruckonSite.il.~NTRLLER1.~114FailureofEOFTelephone SystemI.HEALTHPHYIONTROLLER 1.~114Contaminated Individual ArrivesatTSCJ.HEMIST0NTROLLER 1.~100Hook-upMobileOlTruckandStartPumpingtoOST.

RITIALIMULATORSET-UPDATAFOR12EMERENYPLANNINGSIMLATORRN1.AtQgg)Equipment Set-up-See0700PlantStatussheet.2.AtQ7ggReactorCoreisinMOL(571PPMBoron).3.AtQ7QQRCSLeakRateis0.361GPM.4.AtQ7QO"A"S/GPrimarytoSecondary LeakRateisapproximately 450cc/min (0.125gpm).5.At~070R-15onAlarmandReadingapproximately 4.6x10'pm.6.AtQ730HP/Chemistry ReportstotheControlRoomthatthe"A"S/Gcalculated primarytosecondary LeakRateis450cc/min (i.e.,0.125GPM).7.At~Q745Operators startshuttingthePlantdowninaccordance withthe0-6,10and0-2.1at10%/hrfor2hoursandthenat20%/hrfortherestoftheshutdown.

8.AIL7v~l.hIdbdId,15G<<TbLeakage)0.1GPMasidentified bysampling).

9.AtQ755the"A"S/GARVpopsfullopenandcannotbeclosedfromtheControlRoom.10.At0810the"A"S/GARVIsolation Valveisclosed.11.AtQg~1the"B"S/GARVisreportedtohaveasteamleak.~N:Isolation ofthe"BiaS/GARVcanoccuratanytimefromnowon.12.At0815Annunciator G-22(ADFCSSystemTrouble)Alarms.13.At0830CCWSystemleakof20GPMstarts.14.AtQ640theCCWSurgeTankLoLevelAlarmlA-13lannunciates andtheCCWlevelindicates itisdecreasing.

'I15.At~0!j5.theADFCSProblemisRepaired.

16.At~OQ5the1ACCWPumpSuctionandDischarge Valvesareclosedisolating theleak.TheElectrical Breakerisrackedoutalso.17.At~015the"A"S/Gsustainsatuberuptureofapproximately 700GPM.

RITIALIMLATRET-PDATAFEIVIERENCYPLANNINGSllVILATRRUN(continued) 18.At~QQ;g,analertshouldbedeclared.

(S/GTuberupture)100GPM)19.At~1)DltruckarrivesonSite.20.Atg1)~1the"AtsSWPumptripsout-Annunciator (J-9)alarms.21.At~QanaturalgasleakintheScreenHouseisreportedbyAuxiliary Operatorsentouttocheckthe"A"SWPump.22.At1030OutsideStorageTankEmptyasReportedbyAuxiliary Operator.

23.At~~104aieArEmrnshouldbedeclared(entryofuncontrolled flammable gasesintovitalareas).24.At11QQ,theCSTlevelsdecreasebelow5feet.25.At~111MobileDltruckstartspumpingwatertoOST26.At1120the"ArsS/GARVMercoidisrepaired.

27.At1145the"B"S/GARVsteamleakisrepaired.

28.At~1315theExerciseisterminated.

Time:eggMessage:ICINNATATIN192EVALATEDEXERIEMESSAGEFORMMMMf:SiI1:<<IRSimulaePlanCondiion:SeetheAttachedSheets~Messee:"""THISISANEXERCISE"

>>"FORCONTROLLER USEONLY~G'<<N1)Reviewinitialconditions andPlantstatussheetswiththeExerciseoperating crew.2)ReviewExerciseprecautions/limitations andanyExerciseactivities thatarenormal(pre-staging, simulated notifications, extentofparticipation ofoffsiteagencies, etc.).3)Ensurethattheoperating crewunderstands thattheExerciseisnottointerfere withsafePlantoperations.

4)Explainthatabbreviation "OOS"means"outofservice,"

i.e.repairsmustbemadebeforetheequipment canbeused.AnticiatedResults:1)Participants shouldreviewconditions, Plantdata,andotherprocedures asapplicable.

GINNASTATION1992EMERGENCY PREPAREDNESS EXERCISEINITIALCONDITIONS 1.TheR.E.GinnaNuclearPowerPlantisoperating atapproximately 97%ratedthermalpower.ThePlanthasbeenoperating atthispowerlevelcontinuously forapproximately 150days.2.The"A"SteamGenerator (S/G)primarytosecondary leakrateincreased approximately five(5)daysagotoacalculated 60cc/min.

Atapproximately 0630hoursthismorningtheprimarytosecondary leakratehasagainincreased significantly asindicated byasubstantial increaseinRadiation MonitorR-15(AirEjector).

Radiation MonitorR-19(S/GBlowdown) hasalsoindicated anincreaseinactivity.

TheHealthPhysics/Chemistry Department isintheprocessofanalyzing samplestodetermine thecalculated leakrate.3.Equilibrium primarycoolantisotopicactivityasof0300hours(10/8/92) isprovidedinTable9.2ofScenarioSection9.3.Totalactivityis2.56microcuries/gram.

Chemistry dataisprovidedonExerciseChemistry LogSheet,available fromtheController.

4.TheReactorCoolantSystem(RCS)totalleakageis0.361gpmasof0400hoursthismorningandhasbeenincreasing.

Identified RCSleakageis0.073gpm.5~Generalweatherconditions arepartlycloudywithnocurrentprecipitation.

For'urposesoftheExercise, additional meteorological information intheSimulator ControlRoomshouldbeobtainedfromthePlantProcessComputerSystem(PPCS)~6.ThePrimaryWaterTreatment Plantissecuredformajormaintenance thatwilltakeapproximately three(3)days.The100,000gallonOutsideCondensate StorageTankisat20%level.ademineralizer trailerhasbeenorderedandisscheduled toarriveat1300hourstoday.7.TheHouseHeatingBoilerisinserviceandnuclearsteamissecuredandheld.8.Providegeneralweather(clearconditions) 9.Provideinitialconditions turnoverpaperwork.

199PEVALUATED EXERCISETime:~7ooMAJORPAEVLNETERS ENGINEERED SAFEGUARDS HihHeadS.I.PumsFY-924~GPMFI-925C7GPM1A.INSERVBOOS1B.INSERVTBOOS1CINSERVSTBOOSBASTLevel=LowHeadS.I.PumsFI-6261A.INSERVTBOOSRECIRC,1B.INSERVTBOOSRECIRCRWSTLevel=Containment SraPumsFI-931AOGPMFI-931B0GPM1A.INSERVTB1B.INSERVTBNaOHTankLevel=OOSOOSContainme ecircFans1A.SERSTBYOOS1B.NSESTBOOS1C.INSRVBOOS1D.NSERSTBYOOSPostAccentDampersOPENLOSEDServiceWaterPums1A.SESTBYOOS1B.RSTBYOOS1C.NSRVSTBOOS1D.INSERVSTBOOSA&BHeaderPressure/73PSIGComonentoolinWaterPumsDIESELGENERATORS A.RUNNINGUNLOADEDBOOSB.RUNNINGUNLOADEDBYOOSTSCRUNNINGUNLOADED0SSecurityRUNNINGUNLOADEDTBOOSReactorShutdown~YESN-31~CPSN-32CPSN-35AMPSN-36AMPSAvg.NuclearPowerRCSPressureZzMPSIGPRZRLevelARCPNNISTOPPEDBRCPUNNINSTOPPED1AS/GLevel~Z,.I1BS/GLevel1AS/GPressure/47tzPSIG1BS/GPressure~SOPSIGTurbine/Generator LIOFFLINE4KVBusesNERGIZEDDEENERGIZED 480VBusesNERGIDEENERGIZED DCBatteries A~5oVOLTSB/SbVOLTSnmtPressurePSTGnmtSumpALevel~FEETCnmtSumpBLevelINCHESALoopHotLeg~&AOFALoopColdLeg.SOFBLoopHotLeg7OFBLoopColdLegoFRVLIS~'~e3*CETQb~~e$OFS/GATotalAuxFWFlow0GPMS/GBTotalAuxFWFlow~GPMENGINEERED SAFEGUARDS Aux.Feedwatums1A.INSERVOOS1B.INSERVTBOOSTurb.DrivenINSERVTBOOSSTLevel~FEET1A.NSESOOS1B.INSERVTBOOSSurgeTankLevel=~2StandbAux.FeaterPums1C.INSERVOOS1D.INSERVTBOOS*CET=AverageofSelectedCoreExitThermocouples

8~199207'08R.E.GINASltKATOR7RENDGROUPASSIG)STSU)WARYPAGE16ROUP:EVENT1PROCEDURE:

EPIP1-5PLA)(7STATUSPOINTIDDESCRIPTION (IALE.U.12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152ATMSRXTN31N32N35N36NPPRCSLP2RFRCLAFRVBR)(T16RXT17TSUBTCLSGALS69PSGAPSGBGENBKRlGENBKR2BUS11ABUS11BBUS12ABUS12BB11A12AB11B129PCVLS(NPAL0942EL0943EL0942DL0943DL0942CL0943CL0942BL0943BL0942AL0943AT0409AT0410AT0450T0451TAVGAMIDTAVGBMIDLRVTCCOREFAUXFMAFAUXFMBBKR081BKR082V3505V3504ANTICIPATED TRANSIENT M/0SCRAttREACTORTRIPBREAKERSTATUSSO(mCERANGEDETECTORN-31SO(HCERA%EDETECTSN-32INTERNEDIATE RANEEK7ECTORtt-35INTER)(EDIATE RANGEDETECTORN-36AVERAGEN(KLEARPOMERREfK:TORCQOUNTSYSTEMAVGPRESSPRESSURIlER AVERAGELEVELREACTORCOOUNTLOOPAAVGFLOMREACTORCOOLANTLOOPBAVGFLOMRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPItiCORETCSUBCOOLED NRGINSTNGENANARROMRANGEAVGLEVELSTt(GENBt(ARROMRANGEAVGLEVELSTt(GENAAVERAGEPRESSURESTttGENBAVERAGEPRESSUREGE%MTORONLINEBREAKER161T/2GBGNTORONLINEBREAKER9X1372BUS11ASUPPLYBREAKERBUS11BSUPPLYBREAKERNOTTERt(I)ITED OttPPCS(7/19/91)

NOTTERttINATED OtlPPCS(7/19/91)

BUS11ATO12ATIEBREAKERBUS11BTo12BTIEBREAKERCONTAIN)(ENT AVERAGEPRESSURECONTAINtfENT SUt(PAAVERAGELEVELSSPBLEVEL8ItlCHES(TRAINA)SUtPBLEVEL8INCHES(TRAINB)SUtl'LEVEL78INCHES(TRAINA)SUtPBLEVEL78INCHES(TRAINB)SSPBLEVEL113INCHES(TRAIN A)SU%'LEVEL113INCHES(TRAIN B)SUtPBLEVEL180INCHES(TRAIN A)SU%'LEVEL180INCHES(TRAIN B)SSPBLEVEL214INCHES(TRAIN A)SUtFBLEVEL214INCHES(TRAIN B)RCLAHOTLEGTEtPERATURE RCLBHOTLEGTEt(PERATURE RCLACOLDLEGTEt(PERATNE RCLBCOLDLEGTEtiPERATNE RCLATAVG(TNT/TCOLD MIDERNG)RCLBTAVG(THOT/TCOLD MIOERNG)REACTORVESSELAVERAGELEVELEl~1INCORETCAVERAGETEt(PS/GATOTALAUXFEEDMATER FLOMS/6BTOTALAUXFEEDMATER FLOMt(TRAUXILIARY FEEDMATER PUt(PANTRAUXILIARY FEEDMATER PUt(P9AUXFMPUt(PSTEANSl)PPLYVALVEAAUXFMPUt(PSTEA)lSUPPLYVALVEBNOATMSNOTTRIP1.00000+00 1.00000+00 6.91829-04 6.42686M97.152252.47.998.597.3NOTTRIPNOTTRIP45,452.152.1692.6'90.NQTTRIPNOTTRIPt$7TRIPNOTTRIPNOTTRIPNOTTRIPTRlPPEDTRIPPED.171.6LONERLONERLONERLONERLONERLONERLONERLONERLONERLOWER600.7600.7543;3544.6572.0572.799.3604.50.0.OFFOFFCLOSEDCLOSED60096009INHBCPSINHBCPSINHBleINHBNPGOODX6009PSIGGOODGOOD/6009/60096009600~DEGFGOODGOOD'/6009PSIGGOODPSIGGOODGoon60096009DELDEL60096009600DPSIGGOODFEET6009Goon6009soon60096009600960096009Goon6009DEGF6009DEGF6009DE6FGOODDEGF6009KGFGoonDEGF6009Goo<DEGF6009GPH6009GPt(6009GoonGOOD6009 OCT8~199207:08R.E.GINASI%LATORTRENDGROUPASSIGOENT S1NNRYPAGE26ROUP:EVENTiPROCEDURE:

EPIP1-5PLM'TATUS POINTIDDESCRIPTION VALUEQUALE.U.53FSIASAFETYIN:ECTION LOCPAAVGFLOM54FSIBSAFETYINJECTION LOOPBAV6FLOM55P2160SERVICEMATERPlNPSAhBHEADER56P2161SERVICEMATERPlNPSC5DHEADER57BKR041SERVICEMATERPUNPA58BKR042SERVICEMATERPlNPB59BKR043SERVICEMATERPlNPC60BKR044SERVICEMATERPUN'0.60000.600D81.GOOD73.GOODGOOD600D60096009PN6PHPSI6PSIG PROGRAMNAME:LRGTSZ.E REE.GIHNANUCLEARPOWERPLANTOCT08,92070100TRENDGROUPASSIGNMEHT SUMMARYGROUPNAHEEVENT2GROUPDESCRIPTION PROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURREHTVALUEQUALITYCODEENGRUNITS12345678910111216171e'19202122232425262728293031323334353637383940F0619LRWSTWS033WD033WT033WT250WDT2R01R02R05R09R34R35R10AR11R12R10BR13R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14A5R14A7R14A9R15ASR15A7R15A9R31R32CVHTCV03TCV07TCV08TCV09TCV10TCV17COMPONENT COOLIHGLOOPTOTALFLWREFUELING WATERSTORAGETANKLVL33FOOTLEVELWINDSPEED33FOOTLEVELWINDDIRECTION 33FOOTLEVELTEMPERATURE 250FOOTLEVELTEHPERATURE 250TO33FOOTLEVELDELTATEHPAREA1-CONTROL ROOMAREA2-CONTAINMENT AREA5-SPENTFUELPITAREA9-LETDOWN LINEMONITORAREA34-AUXBLDGCVSPRAYPUHPAREA35-PASSSAMPLEPANELCONTAINMENT IODINEMONITORR'IOACONTAINMENT AIRPARTICULATE CONTAINHENT GASMONITORPLANTVENTIODINEMONITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIQUIDWASTEDISPOSALHONITORSTEAMGENERATOR SLOWDOWNDRAINAREA29-CONTAIHHENT HIGHRANGEAREA30-CONTAINMENT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5LOWRANGEGASCVVEHTCHAN6-AREAGAMMACVVENTCHAN7-MIDRANGEGASCVVENTCHAN9-HIGHRANGEGASPLANTVEHTCHAN5-LOWRAHGEGASPLANTVENTCHAN7-HIDRANGEGASPLANTVENTCHAN9-HIGHRANGEGASAIREJECTORCHAN5-LOWRANGEGASAIREJECTORCHAN7-MIDRANGEGASAIREJECTORCHAN9HlRANGEGASAREA3'ISTEAMLINEA(SPING)AREA32STEAMLINEB(SPING)CVHYDROGENCONCENTRATION CVBASEHENTLVL6FTTEHP¹3CVINTERMEDIATE LVL6FTTEMP¹7CVINTERMEDIATE LVL6FTTEHP¹8CVINTERMEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEHP¹10CVOPERATING LVL6FTTEMP¹171485.94.53.7209.52.955.42.59.02214-02 6.4067eioo 1.39946+00 3.40701+01 9.09354-01 1.09283+00 9.58719+01 5.18901+02 7.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658+03 4.07174+03 5.05861-01 5'9440-014.66390+04 1.89699-07 2.53990-02 3.57435-05 1.41261-03 4.40312-07 6.86543-05 3.72621-03 2.33589-03 2.33337-03 2.33436-03 1.02040.02 1.01048-02

.095.1106.0106.6106.7106.2117.5GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGPMMPHDEG.DEGFDEGFDEGFMR/HMR/HMR/HMR/HMR/HMR/HCPMCPHCPHCPMCPHCPHCPMCPHR/NRR/HRCPHUCI/CCMR/NRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRMR/HRDEGFDEGFDEGFDEGFDEGFDEGF TIme:~715Message:1INNASTATIN192EVALATEDEXERIEMESAGEFRM>>>>>>ft:>>ICIRSilPlanniin:SeetheAttachedSheets~essa<ee:

"""THISISANEXERCISE>>>>>>

Makethefollowing PAannouncement aftersoundingthe"Attention" signal:"Attention; Attention allpersonnel.

TheGinnaNuclearStationisnowstartingits1992Emergency Preparedness Evaluated Exercise.

AllExercisemessagesmustbestartedandendedwith'THISISANEXERCISE'."

Announcetwice.FORCONTROLLER USEONLYController Notes:1)EnsurethatthePAannouncement ismade.AnticiatedResults:1)Simulator ControlRoommakesthePAannouncement.

199K.EVALUATED EXERCISETime:g7/>MAZORPARAMETERS ENGINEERED SAFEGUARDS ReactorShutdown~YES0N-31~CPSN-32CPSN-35AMPSN-36AMPSAvg.NuclearPowerRCSPressurePSIGPRZRLevelARCPUNNINSTOPPEDBRCPUNNZNSTOPPEDlAS/GLevel.I1BS/GLevel~a.1AS/GPressure?PSIG1BS/GPressure0PSIGTurbine/Generator NLIOFFLINE4KVBusesNERGIZDEENERGIZED 480VBusesRGZZDEENERGIZED DCBatteries A/SbVOLTSBISOVOLTSnmtPressure~IPSIGnmtSumpALevel~FEETCnmtSumpBLevelINCHESALoopHotLeg~OFALoopColdLeg~g.SOFBLoopHotLeg0.'7OFBLoopColdLeg~59~OFRVLIS1.9*CETOFS/GATotalAuxFWFlow0GPMS/GBTotalAuxFWFlowGGPMDIESELGENERATORS A.RUNNINGUNLOADEDOOS.BRUNNINGUNLOADEDTBOOSTSCRUNNINGUNLOADEDTBOOSSecurityRUNNINGUNLOADEDTBOOSENGINEERED SAFEGUARDS Aux.Feedwater Pums1A.INSERVTBOOS1B.INSERVOOSTurb.DrivenINSERVTBOOS.STLevel~FEETHihHeadS.I.PumsFI-924C7GPMFI-925C7GPM1A.INSERVT1B.INSERV1C.INSERVBASTLevel=OOSOOSOOSLowHeadS.I.PumsFI-6260GPM1A.INSERVTBOOSRECIRC1B.INSERVTBOOSRECIRCRWSTLevel=Containment SraPumsFI-931AO'PMFI-931B~GPM 1A.INSERVT1B.INSERVTBNaOHTankLevel=OOSOOSContainment RecircFans1A.NSERSTBYOOS1B.SERVSTBYOOS1C.INSVTBOOS1D.SERSTBYOOSPostAcesentDampersOPENLOSEDServiceWatPums1A.SSTBYOOS.1B.SSTBYOOS1C.NSESTBYOOS1D.INSERVTBOOSA&BHeaderPressureSPSIGComonentCoolinWaterPums1A.SESTBYOOS1B.INSERVBOOSSurgeTankLeve=~yStandbAux.FeeaterPums1C.INSERVTBOOS1D.INSERVOOS*CET=AverageofSelectedCoreExitThermocouples 0

07:16R.E.GINASit(ULATOR TRENDGROUPASSIGN)IENT SUI(tIARY PAGE1GROUP:EVENTlPROCEDURE:

EPIP1-5PLANTSTATUS12356789101112131415161718192021.u242526272829303132343536373839404142434445465152POINTIDATMSRXTN31N32N35N36t(PPRCSLPZRFRCLAFRCLBRXT16RXT17TSUBTCLSGA'SGBPSGAPSGBGENBKRlGENBKR2BUS11ABUSliBBUS12ABUS12BB11A12AB11B12BPCVLS(NPAL0942EL0943EL0942DL09439L0942CL0943CL0942BL0943BL0942AL0943AT0409AT0410AT0450T0451TAVGAMIDTAVGBMIDLRVTCCOREFAUXFMAFAUXFMBBKR081BKR082V3504DESCRIPTION ANTICIPATED TRANSIENT M/0SCRAtIREACTORTRIPBREAKERSTATUSSMKERANGEDETECTORN-31SOlRCERA)IGEDETECTORN-32INTE)mEDIATE RANGEDETECTORN-35INTERI(EDIATE RANGEDETECTORN-36AVERAGENUCLEARPOWERREACTORCOOLANTSYSTE)(AVGPRESSPRESSURIZER AVERAGELEVELRHETORCOOLANTLOOPAAVGFLGMREACTGRCOOLANTLOOPBAVGFLOMRCPABREAKERCAUSERXTRIPIKPBBREAKERCAUSERXTRIPINCORETCSUBCOOLED t(ARGINST)IGENANARROMRANGEAVGLEVELSTI(GE)lBNARROMRANGEAVGLEVELSTNGENAAVERAGEPRESSURESTtfGEtlBAVERAGEPRESSUREGBGQTORONLINEBREAKER!61372GBERATORONLINEBREAKER9X1372BUS11ASUPPLYBREAKERBUS11BSL4'PLYBREAKERNOTTER)IINATED ONPPCS(7/19/91)

NOTTER)IINATED ONPPCS(7/f9/91)

BUS11ATO12ATIEBREAKERBUS119TO12BTIEBRENERCONTAINIIENT AVERAGEPRESURECoiWAINMEI(T SUI(PAAVERAGELEVELSU)PBLEVEL8ItlCHES(TRAINA)SUtPBLEVEL8ItlCHES(TRAINB)SSPBLEVEL78INCHES(TRAINA)SUI(PBLEVEL78INCHES(TRAINB)SSPBLE4l3.f13INCHES(TRAIN A)SUtPBLEVEL113INCHES(TRAIN B)SU%'LEVEL180INCHES(TRAItl A)SUtFBLEVEL180INCHES(TRAIN B)SSPBLEVEL214INOKS(TRAIN A)SU%'LEVEL214INCHES(TRAIN B)IKLAHOTLEGTE)(PERATUfE RCLBHOTLEGTEt(PERATNK RCLACOLDLEGTPiPERATIRE RCLBCGI.DLEGTE)IPERATlRE RCLATAVG(THQT/TCOLD WIDERNG)RCLBTAVG(THOT/TCOLD MIDERNG)REACTORVESSELAVERAGELEVELEl~1It/CORETCAVERAGETEtPS/6ATOTALAUXFEEDMATER FLGMS/GBTOTALAUXFEEDMATER FLOWt(TRAUXILIARY FEEDMATER PU)IPAt(TRAUXILIARY FEEDMATER PUI(P9AUXFMPUI(PSTEANSUPPLYVALVEAAUXFMPUi"PSTEANSUPPLYVALVEBVALUENOATMSNOTTRIP1.00000KO1.0005&06.918Ã-04 6.42686M97.162252.48.098.597.3NOTTRIPNOTTRIP45.452.152.1692.690.NOTTRIPNOTTRIPNOTTRIPNOTTRIPNOTTRIPNQTTRIPTRIPPEDTRIPPED.111.6LONERLONERLOWERLOWERLONERLONERLONERLOWERLOWERLONER600.7600.7543.3544.6572.0572.799.3604.50.0.OFFOFFCLOSEDCLOSED60096009INHBINHBINHSINHH6009GOOD60096009GOOD6009Goon600~60096009GOODGOODGOODGOOD6009GoonDELDEL6009GOOD6009600960096009GoonGoon600960096009GoonGOOD6009GOOD6009Goon6009soon6009GOOD600860096009GoonGOODE.U.CPSCPSNPAt(PPSIGXXXDEGFX/PSIGPSIGPSIGFEETDEGFDEGFDEGFDEGFDEGFDE6FXDE6FGPNGPI(8'-l7 XT8~199207!16R.E.GINASIHL&TORTRENDGROUPASSIGNNEhT RNNRYPAGE26ROUP:EVENT1PROCEDURE!

EPIP1-5PLANTSTATUSPOINTID53FSIA54FSIB55P216056P216157BKR04158BKR0425'PBKR04360BKR044DESCRIPTION SAFETYIN.'ECTION LOOPAAVGFLOMSAFETYINJECTION LOOPBAVGFLOMSERVICEMATERPUFFSAhBHEADERSERVICEMATERPlDIPSChDHEADERSERVICEMATERPUtFASERVICEMATERPUNPBSERVICEMATERPIIPCSERVICEMATERPINPDONONONOFF0.GOOD0.GOOD81~GOOD73.GOODGOODGOODGOODGOODGPNPNPSI6PSIGVALUEQUALE.U.

~~~ROGRAMNAME:LRGTS2.E R.E.GIHHANUCLEARPOWERPLANTOCT08,9207:15:00TRENDGROUPASSIGHMEHT SUMMARYGROUPNAMEEVENT2GROUPDESCRIPTIONPROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTIONCURRENTVALUEQUALITYCODEENGRUNITS1234567891011121314181920212223242526272829303132333435363738394041424,F0619LRWSTWS033WDO33WT033WT250WDT2R01R02R05R09R34R35R10AR11R12R108R13R14R18R19R29R30R'l5R12A5R12A6R12A7R12A9R14ASR14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03TCV07TCV08TCV09TCV10TCV17COMPONENT COOLINGLOOPTOTALFLWREFUELING WATERSTORAGETANKLVL33FOOTLEVELWINDSPEED33FOOTLEVELWINDDIRECTION 33FOOTLEVELTEMPERATURE 250FOOTLEVELTEMPERATURE 250TO33FOOTLEVELDELTATEMPAREA1-CONTROL ROOMAREA2-COHTAINHENT AREA5-SPENTFUELPITAREA9-LETDOWN LINEMONITORAREA34-AUXBLDGCVSPRAYPUMPAREA35-PASSSAMPLEPAHELCOHTAIHHEHT IODINEMONITORR10ACONTAINMENT AIRPARTICULATE COHTAINMEHT GASMONITORPLANTVENTIODINEMONITORR108AUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIQUIDWASTEDISPOSALMONITORSTEAMGENERATOR BLOWDSSDRAINAREA29-COHTAIHMEHT HIGNRANGEAREA30-CONTAINMENT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LOWRANGEGASCVVENTCHAN6.AREAGAMMACVVENTCHAN7-MIDRANGEGASCVVENTCHAN9HIGHRANGEGASPLANTVENTCHAN5-LOWRANGEGASPLANTVENTCHAN7-MIDRANGEGASPLANTVENTCHAN9-HIGHRANGEGASAIREJECTORCHAN5-LOWRANGEGASAIREJECTORCHAN7-MIDRANGEGASAIREJECTORCHAN9-HIRANGEGASAREA31STEAHLINEA(SPIHG)AREA32STEAMLINE8(SPIHG)CVHYDROGENCONCENTRATION CVBASEMENTLVL6FTTEHP¹3CVIHTERMEDIATE LVL6FTTEMP¹7CVIHTERMEDIATE LVL6FTTEMP¹8CVINTERMEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEMP¹10CVOPERATING LVL6FTTEMP¹171485.94.53.8193.52.955.52.69.02214-02 6.40678+00 1.39946+00 3.40701+01 9.09354-01 1.09283+00 9.58719+01 5.18901+02 7.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658+03 4.07174+03 5.05861-01 5.09440-01 8.75390+04 1.89699-07 2.53990-02 3.57435-05 1.41261-03 4.40312-07 6.86543-05 3.72621-03 4.39589-03 4.39337-03 4.39436-03 1.02040.02 1.01048-02

.095.1106.0106.6106.7106.2117.5GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGPMMPHDEG.DEGFDEGFDEGFMR/HMR/HMR/HMR/HMR/HMR/HCPMCPMCPMCPMCPMCPMCPMCPMR/HRR/HRCPMUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRMR/HRDEGFDEGFDEGFDEGFDEGFDEGF INNASTATIONTime:~7'essage:

212EVALUATED EXERIE~MEEAGE3RM~MI:GI<<G<<IRimlaePlannIIn:SeetheAttachedSheets~IVI<<c~a:"""THISISANEXERCISE"""

The"A"S/Gcalculated leakrateisapproximately 450cc/min.

FRCNTRLLERUSEONLY1)ThismessagetobecalledintotheSimulator ControlRoombytheSimulator operatoractingastheHPtechnician.

AniiRI1)Operators shouldbeginperforming theApplicable ActionsofOperating Procedure 0-6.10(PlantOperation withSteamGenerator TubeLeakIndication).

2)AnorderlyPlantshutdownshouldcommencetobeinHotShutdownwithinsix(6)hoursandtobelessthan350'FintheRCSwithinthenextsix(6)hoursasrequiredbyPlantTechnical Specifications.

31A~UI3IdddIdIdIREPIPI.G."GI StationEventEvaluation andClassification,"

EAL:SteamGenerator TubeRupture(SGTR);SteamGenerator TubeLeakage>.1gpmasidentified bysamplingorEAL:ReactorCoolantLeakage(RCS);SteamGenerator TubeLeakage).1gpm asidentified bysampling.

Appropriate offsitenotifications shouldbemadeperEPIP1-5.4)Operators shouldalsobeperforming theapplicable actionsofthefollowing procedures:

a)EPIP1-1(UnusualEvent)b)EPIP5-7(Emergency Organization) c)0-9.3(NRCImmediate Notification).

199K'EVALUATED EXERCISETime:~73+MAZORPARAMETERS

'NGINEERED SAFEGUARDS HihHeadS.I.PumsFI-9240GPMFI-925OGP1A.INSERVBOOS1B.INSERVTBOOS1C.INSERVTBOOSBASTLevel=LowHeadS.X.PumsFI-626OGPM1A.XNSERVTOOSRECIRC1B.INSERVSBOOSRECIRCRWSTLevel=Containment SraPumsFI-931AOGPMFI-931BOGP1A.INSERVTBOOS1B.INSERVTOOSNaOHTankLevel=Containmen ecircFans1A.NSERVSTBYOOS1B.NSEVSTBYOOS1C.INERVTBOOS1D.NSESTBYOOSPostAccidentDampersOPENCLOSEDServiceWaterPums1ANSSTBYOOS1B.NSESTBYOOS1C.NSESTBYOOS1D.INSERVOOSA&BHeaderPressurePSIGComonentoolinWaterPumsDIESELGENERATORS A.*'RUNNING UNLOADEDBOOSB.RUNNINGUNLOADEDTBOOSTSCRUNNINGUNLOADEDOOSSecurityRUNNINGUNLOADEDTOOSReactorShutdownYES0N-31~CPSN-32~CPSN-35~AMPSN-36AMPSAvg.NuclearPowerRCSPressuregg.~PSIGPRZRLevel.IARCPINGSTOPPEDBRCPUNNISTOPPEDlAS/GLevel1BS/GLevel1AS/GPressure~pPSIG1BS/GPressureOPSIGTurbine/Generator LXNOFFLINE4KVBusesRGIZEDEENERGIZED 480VBusesNERGXZEDEENERGXZED DCBatteries A)70Bgg0VOLTSCnmtPressure~~PSIGnmtSumpALevelFEETCnmtSumpBLevelINCHESALoopHotLeg0.OFALoopColdLegOFBLoopHotLegbOeOFBLoopColdLegOFRVLIS*CET~o~OFS/GATotalAuxFWFlowOGPMS/GBTotalAuxFWFlowMGPMENGINEERED SAFEGUARDS Aux.Feedwater ms1A.INSERVOOS1B.INSERVTBOOSTurb.DrivenINSERVBOOS~STLevel2FEET1A.SERSTBOOS1B.INSERVTBOOSSurgeTankLeveStandbAux.FeedaterPums1C.INSERVTBOOS1D.INSERVTBOOS*CET=AverageofSelectedCoreExitThermocouples

OCT8~199207:30R.E.GINASIMULATOR TRENDGROUPASSIGQBi7 SUt(MARYPAGE1GROl)P:EVENTlPROCEDURE'PIP 1-5PLANTSTATUSPOINTIDDESCRIPTION VALUEQUALE.U,1234567810ll1213141516171819202122232425262728293031323334353637383940414243444546474849505152AT%RXTN31N32N35N36NPPRCSLPIRFRCLAFRCLBRXT16RXT17TSUBTCLSGALSGBPSGAPSGBGENBKRlGENBKR2BUS11ABUS118BUS12ABUS128811A12A811812BPCVLSRFAL0942EL0943EL0942DL0943DL0942CL0943CL09428L09438L0942AL0943AT0409AT0410AT0450T0451TAKAMIDTAVGBMIDTCCGREFAUXFMAFAUXFMBBKR081BKR082V3505V3504ANTICIPATED TRANSIENT M/0SCRAMREACTORTRIPBREAKERSTATUSSmSCERANGEDETECTGRN-31So(HCERANGEDETECTORN-32INTERMEDIATE RANGEDETECTORN-35INTERMEDIATE RAN6EDETECTORN-36AVERAGEl(XLEARPOWERREACTORCOOLANTSYSTEMAVGPRESSPRESSURIZER AVERAGELEVELREACTORCGOLN(TLOOPAAVGFLGMREACTORCOOLANTLOOP8AVGFLGMRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCGRETCSUBCOOLED MAfFaINSTMGENANARROWRANGEAVGLEVELSTMGEN8NARROMRA%EAVGLEVELSTMGENAAVERAGEPRESPJRESTtfGEN8AVERAGEPRESSUREGBGQTORONLINEBREAKER1G1372GEtGQTORONLINEBREAKER9X1372BUS11ASUPPLYBREAKERBUS118SUPPLYBREAKERNOTTERMINATED OWPPCS(7/19/91)

NOTTERMINATED OWPPCS(7/19/91)

BUS11ATo12ATIEBREAKERBUS118TO128TIEBRENERCONTAINMENT AVERAGEPRESSURECONTAINMENT SUMPAAVERAGELEVELSUMP8LEVEL8INCHES(TRAINA)SU%'LEVEL8INCHES(TRAINB)SSP8LEVEL78INC)iES(TRAINA)SU)P8LEVEL78INCHES(TRAIN8)SSP8LEVEL113INCHES(TRAIN A)SU)P8LEVEL113INCHES(TRAIN 8)SUtP8LEVEL180INCHES(TRAIN A)SUtP8LEVEL180INCHES(TRAIN 8)SUMP8LEVEL214INCHES(TRAIN A)SUtP8LEVEL214INCHES(TRAIN 8)RCLAHOTLEGTEMPERATURE RCLBHOTLEGTEMPERATURE RCLACOLDLEGTEtfPERATlSE RCLBCOLDLEGTE)fPERAT(SE RCLATAVG(TNT/TCOLD WIDERNG)RCLBTAVG(THOT/TCOLD WIDERNG)REACTORVESSELAVERAGELEVELEl.1INCORETCAVERAGETEMPS/GATOTALAUXFEEDMATER FLOWS/G8TOTALAUXFEEDMATER FLOWMTRAUXILIARY FEEDMATER PUMPAMTRAUXILIARY FEEDMATER PUMP8AUXFMPUMPSTEA)fSUPPLYVALVEAAUXFMPUt(PSTEAMSUPPLYVALVE8NoATMSNOTTRIP1.00000+001.00000%0 6.91829M6.42686M97.152252.48.198.597.3NOTTRIPNOTTRIP45.452.152.1692.690.NOTTRIPNOTTRIPNOTTRIPNOTTRIPNOTTRIPNOTTRIPTRIPPEDTRIPPED.081.7LOWERLOWERLOWERLOWERLONERJ.ONERLOWERLOWERLONERLONER600.7600.7543.3544.6572.0572.799.3604.50.0.OFFOFFCLOSEDCLOSEDGoonGoonINHBINHBINHBINHBGOODGOOD600D6008GOODGOODGoon6004GOODGoonGoonGOODGOOD6008GOODGOODDELDELGoonGOODGoonGOODGOOD600DGOODGOODGOODGoonGOODGOODGOODGoon600DGoonGOODGoonGoonGOODGOOD600~GOODGOODGOODGOODGOODGOODCPSCPSA!(PAMP7,PSIGe/y./0DEGF//PSIGPSIGPSIGFEETDE6FDEGFDEGFDEGFDEGFDEGFXDEGFGPM OCT8~199207:30R.E,GINASINLATORTRENDGROUPASSIGt4tlENT SUtNARYPAGE26ROUP:EVEt4TIPROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION 53FSIA54FSIB55P216056P216157BKR04158BKR04259BKR04360BKR044SAFETYIt43ECTION LOOPAAVGFLOMSAFETYIN.'tECTION LOOP8AVGFLOMSERVICEMATERPUtlPSAhBHEADERSERVICEMATERPUtlPSChDHEADERSERVICEMATERPUtlPASERVICEMATERPUtlP8SERVICEMATERPUtlPCSERVICEMATERPUtlPDONONONOFFVALUENAL0.GOOD0.GOOD81.GOOD73.GOODGOOD600DGOODGOODE.U.GPtlGPtlPSIGPSIG PROGRAMNAHE:LRGTSZ.E R.E.GINNANUCLEARPOWERPLANTOCT08,9207:31:00TRENDGROUPASSIGNHENT SUMMARYGROUPNAHEEVENT2GROUPDESCRIPTION PROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURREHTVALUEDUALITYCODEENGRUNITS2345678910111213192021222324252627282930313233343536373839404142F0619LRWSTWS033WD033WT033WT250WDT2R01R02R05R09R34R35R10AR11R12R108R13~R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14A5R14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03TCV07TCV08TCV09TCV10TCV17COMPONENT COOLINGLOOPTOTAI.FLWREFUELING WATERSTORAGETANKLVL33FOOTLEVEL'WINDSPEED~33FOOTLEVELWINDDIRECTIOH 33FOOTLEVELTEHPERATURE 250FOOTLEVELTEMPERATURE 250TO33FOOTLEVELDELTATEHPAREA1-CONTROL ROOHAREA2-CONTAINHENT AREA5-SPENTFUELPITAREA9-LETDOWN LINEMOHITORAREA34-AUXBLDGCVSPRAYPUMPAREA35-PASSSAHPLEPANELCONTAIHHEHT IODINEMONITORR10ACONTAINMENT AIRPARTICULATE CONTAINMENT GASMONITORPLANTVENT1001NEMONITORR108AUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIQUIDWASTEDISPOSALMONITORSTEAHGEHERATOR SLOWDOWNDRAINAREA29-CONTAINMENT HIGHRANGEAREA30-CONTAINHENT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LOWRANGEGASCVVENTCHAN6-AREAGAMMACVVENTCHAN7-HIDRANGEGASCVVENTCHAN9-HIGHRANGEGASPLANTVEHTCHAN5LOWRANGEGASPLANTVENTCHAN7-HIDRANGEGASPLANTVENTCHAN9-HIGHRANGEGASAIREJECTORCHAN5-LOWRANGEGASAIREJECTORCHAN7MIDRANGEGASAIREJECTORCHAN9-HIRANGEGASAREA31STEAMLIHEA(SPING)AREA32STEAHLINE8(SPING)CVHYDROGENCONCENTRATION CVBASEMENTLVL6FTTEHP¹3CVINTERMEDIATE LVL6FTTEHP'¹7CVINTERHEDIATE LVL6FTTEHP¹8CVINTERMEDIATE LVL6Fl'EHP¹9CVINTERMEDIATE LVL6FTTEMP¹10CVOPERATING LVL6FTTEMP¹171485.94'3.6202.53.055.52.59.02214-02 6.40678+00 1.39946+00 3.40701+01 9.09354-01 1.09283+00 9.58719+01 5.18901+02 7.38002+02 4.30543<01 8.58327+01 4.22831+01 2.78658+03 4.07174+03 5.05861-01 5.09440.01 1'5835+051.89699-07 2.53990.02 3.57435-05 1.41261-03 4.40312-07 6.86543-05 3.72621-03 6.29179-03 6.29392-03 6.29436.03 1.02040.02 1.01048-02

.095.1106.0106.6106.7106.2117.5GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOGOGOODGOODGOGOGOODGOODGOODGOODGOODGOODGOODGOODHALHGOODGOODGOODGOODGOODGOODGOODHALHHWRNGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGPMxHPHDEG.DEGFDEGFDEGFMR/HHR/HHR/HMR/HHR/HMR/HCPHCPHCPHCPHCPMCPMCPHCPMR/HRR/HRCPMUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRHR/HRDEGFDEGFDEGFDEGFDEGFDEGF

'

Time:(L7~4Message:~GINNASTATION192EVALATEDEXERIEMESSAGEFORM~M:8I<<CIRSirnulaedPlantConditions:

SeetheAttachedSheets~essa<ee:

"""THISISANEXERCISE"""

FORCONTROLLER USEONLYController Notes:AniciatedResults:1)Operators shouldbeperforming theapplicable actionsofthefollowing procedures:

a)0-6.10(PlantOperation WithSteamGenerator TubeLeakIndication).

b)0-2.1(NormalShutdowntoHotShutdown).

c)S-3.3C(H,or0,RemovalFromPrimarySystembyBurpingVolumeControlTankWithN2}.d)S-3.3D(CVCSCationDemineralizer BEDOperations UsingDeborating DIAUnit.

199K'EVALUATED EXERCISETime:07t4MAJORPARAMETERS ENGINEERED SAFEGUARDS A.RUNNINGUNLOADEDTBOOSB.RUNNINGUNLOADEDSTBOOSTSCRUNNINGUNLOADEDOOSSecurityRUNNINGUNLOADBENGINEERED SAFEGUARDS Aux.Feedwater ms1A.INSERVTBOOS1B.INSERVBOOSTurb.DrivenINSERVTBOOSSTLevel~gFEOOSReactorShutdownYES0N-31CPSN-32CPSN-35AMPSN-36f.'~CLAMPS Avg.NuclearPowerRCSPressureVPSIGPRZRLevel,ARCPUNNISTOPPEDBRCPUNNINSTOPPED1AS/GLevel.Q.t.41BS/GLevel1AS/GPressure~~PSIG1BS/GPressurePSIGTurbine/Generator NLINOFFLINE4KVBusesERGIZEDEENERGIZED 480VBusesNERGIZEDEENERGIZED DCBatteries A~SaVOLTSB/ZOVOLTSnmtPressure~GPSIGnmtSumpALevelFEETCnmtSumpBLevelINCHESALoopHotLegdnafOFALoopColdLeg.~)~/OFBLoopHotLegdO.OFBLoopColdLegVS'.OFRVLIS'KX-.k~*CETOF5/GATotalAuxFWFlow~GPMS/GBTotalAuxFWFlow0GPMDIESELGENERATORS HihHeadS.I.PumsFI-9240GPMFI-925~GPM1AINSERVTBOOS1B.INSERVTBOOS1CINSERVSTBOOSBASTLevel=LowHeadS.I.PumsFI-626GP1A.INSERVBOOSRECIRC1B.INSERVTBOOSRECIRCRWSTLevel=Containment SraPumsFI-931A0GPMFI-931BGP1A.INSERVOOS1B.INSERVTBOOSNaOHTankLevel=Containme tecircFans1A.SERSTBYOOS1B.NSERSTBYOOS1C.INSERVTBOOS1D.NSERSTYOOSPostAccidentDampersOPENServiceWaterPums1A.STBYOOS1B.STBYOOS1C.ERSTBYOOS1D.INSERVTBOOSA&BHeaderPressureLOSEDPSIGComonenolinWaterPums1A.ESTYOOS1B.INSERVTBOOSSurgeTankLevel=~vStandbAux.FedwaterPums1C.INSERVOOS1DINSERVTBOOS*CET=AverageofSelectedCoreExitThermocouples 8i199207:44R.E.GINASltmLATOR TREtfDGROUPASSIG)IEt(T SU)L%8YPAGE16RQUP:EVENT1PROCEDURES EPIP1-5PLANTSTATUS123567891011121314151617181920212223242526272829303132333435.3637383940414243444546474849505152POINTIDATl6RXTN31N32N35N36NPPRCSLPIRFRCLAFRCLBRX716RXT17TSUBTCLSGALS6BPSGAPSGBGEtfBKR1GENBKR2BUSlIABUS11BBUS12ABUS12BBl1A12ABiiB12BPCVLS(SPAL0942EL0943EL0942DL09430L0942CL0943CL0942BL0943BL0942AL0943A70409A70410A7045070451TAVGAMIDTAVGBMIDLRVTCCOREFAUXFMAFAUXFMBBKR081BKR082V3505V3504DESCRIPTION ANTICIPATED TRANSIENT M/0SCRNREACTORTRIPBREAKERSTATUSSO(ICERAt(GEDETECTORN-31SINCERAtiGEDETECTORN-32INTERtfEDIATE RAN6EDETECTORN-35INTER)(EDIATE RAN6EDETECTORN-36AVERAGENUCLEARPQMERREACTORCOOLANTSYSTEHAVGPRESSPRESSURIIER AVERAGELEVELRFAC70RCCQLANTLQQPAAVGFLOMRECTORCQOLAtfTLOOPBAVGFLQMRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCORE7CSUBCOQLED NRGINSTt(GEtfANARROMRANGEAVGLEVELSTHGENBNARROMRANGEAVGLEVELSTtfGENAAVERAGEPRESSURESTHGENBAVERAGEPRESSUREGEtGQTORONLINEBPEAKER161372GBERATORONLINEBREAKER9X1372BUSiiASUPPLYBREAKERBUS11BSLYLYBREAKERNOTTERMINATED ONPPCS(7/19/91)

NOTTER)(INATED OtfPPCS(7/19/91)

BUSllATo12ATIEBRENERBUS11BTQ128TIEBRENERCONTAltfMEt(7 AVERAGEPRESSURECQNTAINtfEtlT SU)(PAAVERAGELEVELSEP8LEVEL8ItfCHES(TRAINA)SU%'LEVEL8INCHES(TRAIN8)SUNUPBLEVEL78INCHES(TRAINA)SUNUPBLEVEL78INCf.:cS(TRAINB)SU%'LEVEL113INCHES(TRAIN A)SU%'LEVEL113INCHES(TRAIN B)SUtPBLEVEL180INCHES(TRAIN A)SUt1'LEVEL180INCHES(TRAIN B)SUtpBLEVEL214INCHES(TRAIN A)-SU)PBLEVEL214INCHES(TRAIN B)RCLAHOTLEGTEMPERATURE RCLBHOTLEGTEt(PERATUK RCLACOLDLEGTEtlPERATNE RCLBCOLDLEGTEtfPERATNE RCLATAVG(THOT/TCOLD MIDERNG)RCLBTAVG(THOT/TCOLD MIDERNG)RGtTORVESSPAVERAGELEVELEl.lIWCORETCAVERAGETEt(PS/GATOTAlAUXFEETiMATER FLI{S/GB.OTALAUXFEEDMATER FLOMN7RAUXILIARY FEEDMATER PU)(PAMTRAUXILIARY FEEDMA7ER PUHPBAUXFMPUt4PSTEAtlSUPPLYVALVEAAUXRlPUicPSTEA)(SUPPLYVALVEBOFFOFFCLOSEDCLOSEDVALUEQUALNoATMSGOODNQTTRIPGOOD1.00000+00 INHB1.00000+00 INHB6.85487MINHB6.36793MINHB96.1960092280.HMRt(48.7GQQD98.4600997.3600DNOTTRIP600DNOTTRIP600047.2Goo'2.2600952.260007()0.GOOD698.GOODNQTTRIPGOODNOTTRIPGOODNOTTRIP600DNQTTRIP6009NOTTRIPDELNOTTRIPDELTRIPPEDGOODTRIPPEDGOOD~OhGOOD1.7GQQDLONERGOODLOMER6009LONERGOODLOMER600DLOMER600DLONER600DLONERGOODLOWERGOODLONERGOODLOMER6009600.9GOOD600.9GOOD544.1GOOD545.4GOOD572.5600D573.1GQQD99.3GOOD604.6Goo'.60000.6000GOODGOODGOOD600DE.U.CPSCPSAl(PAt(Py.PSIG7.XDEGFÃ/PSIGPS16PSIGFKTDEGFKBFDEGFDE6FDEGFDEGFXDEGFPt(GPt(

OCT8~199207:44R.E.GINASIMULATOR TREND6ROUPASSIGNNEhT RNNARYPAGE26ROUP:EVENTlPRXEDURE:

EPIP1-5PLANTSTATUSPOINTID53FSIA54FSIB55P2ib05bP2ibi57BKR04158BKR0425'9BKRO43b0BKR044E-0-JDESCRIPTION SAFEIN:ECTION LOOPAAVGFLOWSAFETYINJECTION LOOPBAVGFLOWSERVICEWATERPNFSA&BHEADERSERVICEWATERPlÃi'SC&DHEADERSERVICEWATERPUNPASERVICEMATERPUPBSERVICEMATERPUtFCSERVICEWATERPtNPDIONONONOFFVALUEQUAL0.60090.600981.600973.GOOD6000GOODGOODGOODE.U.9'NGPNPSIGPSIG

~~~GRAMNAME:LRGTSZ.E

.E.GINNANUCLEARPSIERPLANTOCT08,9207:46:00TRENDGROUPASSIGNMENT SUMMARYGROUPNAHEEVENT2GROUPDESCRIPTIOH PROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURRENTVALUEQUALITYCODEENGRUNITS1234567891011121314202122232425262728293031323334353637383940414243-F0619ILRHST'NS033l$033NT033MT250lQT2R01R02R05R09R34R35R10AR1'1R12R10BR13R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14A5R14A7R14A9R15A5R15A7R'l5A9R31R32CVHTCV03TCV07TCV08TCV09TCV10TCV17COMPOHENT COOLINGLOOPTOTALFLllREFUELIHG HATERSTORAGETANKLVL33FOOTLEVELIJINDSPEED33FOOTLEVELWINDDIRECTION 33FOOTLEVELTEMPERATURE 250FOOTLEVELTEMPERATURE 250TO33FOOTLEVELDELTATEMPAREA1-CONTROL ROOMAREA2-CONTAINMENT AREA5-SPENTFUELPITAREA9-LETDOWN LINEMONITORAREA34-AUXBLDGCVSPRAYPUMPAREA35-PASSSAMPLEPANELCONTAINMENT IODINEMONITORR10ACONTAINMENT AIRPARTICULATE CONTAINMENT GASMONITORPLANTVENTIODINEMONITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIQUIDHASTEDISPOSALMONITORSTEAHGEHERATOR BLSSOMNDRAINAREA29-COHTAINHEHT HIGHRANGEAREA30-CONTAINMEHT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LOWRANGEGASCVVENTCHAN6-AREAGAMMACVVENTCHAN7-HIDRANGEGASCVVENTCHAH9-HIGHRANGEGASPLANTVENTCHAN5-LOURANGEGASPLANTVENTCHAN7-MIDRANGEGASPLAHTVENTCHAN9-HIGHRANGEGASAIREJECTORCHAN5-LOURAHGEGASAIREJECTORCHAN7-HIDRAHGEGASAIREJECTORCHAN9HIRANGEGASAREA31STEAMLINEA(SPING)AREA32STEAMLINE8(SPING)CVHYDROGENCONCENTRATION CVBASEMENTLVL6FTTEMP¹3CVINTERMEDIATE LVL6FTTEMP¹7CVINTERHEDIATE LVL6FTTEHP¹8CVINTERMEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEMP¹10CVOPERATING LVL6FTTEHP¹171485.94.53.8215.53.555.62.19.02214-02 6.40678+00 1.39946+00 3.40701+01 9.09354-01 1.09283+00 9.58715401 5.18901+02 7.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658+03 4.07174+03 5.05861-01 5.09440.01 1.25835+05 1.89699.07 2.53990-02 3.57435-05 1.41261-03 4.40312-07 6.86543-05 3.72621-03 6.29179-03 6.29392-03 6.29436-03 1.02040-02 1.01048-02

.095.1106.0'106.6106.7106.2117.5GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALHGOODGOODGOODGOODGOODGOODGOODHALHHEARNGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGPMMPHDEG.DEGFDEGFOEGFMR/HMR/HMR/HMR/HMR/HMR/HCPMCPMCPMCPMCPMCPMCPHCPMR/HRR/HRCPMUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRMR/NRDEGFDEGFDEGFDEGFDEGFDEGF Time:0759Message:4X~GI~NATATIGN12EVALATEDEXERIEMESSAGEFORM~MI:MI<<G<<IRRMIPpSimulaedPlanCondiions:~Messee:"""THISISANEXERCISE"

>>"DeclareanUNUSUALEVENTinaccordance withEPIP1-0,"GinnaStationEventEvaluation andClassification,"

EAL:SteamGenerator TubeRupture(SGTR);SteamGenerator TubeLeakage).1gpmasidentified bysamplinggrEAL:ReactorCoolantLeakage(RCS);SteamGenerator TubeLeakage>.1 gpmasidentified bysampling.

FORCONTROLLER USEONLYController Notes:dlilyifGIdPPdId.~ddliifEmerencClaification disussionsareinrors.AniciatedReult:1)Delivercontingency messageifUnusualEventnotdeclaredorisnotbeingdiscussed.

Time:~75!jMessage:~~l~NAAffN1992EVALUATED EXERISEMESAEFRM~MI:NIININSimlaedPlanConiions:~Messee:"""THISISANEXERCISE>>""

The"A"S/GARVhasinadvertently opened.FORCONTROLLER USEONLY~NIIN1)Whenoperators trytomanuallyclosethe"A"S/GARV,itwillnotclose.2)Controller togowithAuxiliary OperatorsenttoSteamHeaderwithMini-Scenarios for"A"8c"B"S/GARVproblems.

AnticiatedResults:1)Operatorshouldshiftthe"A"S/GARVController tomanualandtrytocloseit.2)ControlRoomshouldsendanAuxiliary OperatortotheSteamHeaderareatoclosetheisolation valveonthe"A"S/GARVwhenitcannotbeclosedfromtheControlBoard.

Time:~755Message:~GINNASTATION1992EVALUATED EXERIE~MESAGEFDRRII:AIIIFDF<<II<<RASIGARVSimlaPlanCndiion:SeetheAttachedSheets~INessee:<<>>>>THISISANEXERCISE"

>>"FORCONTROLLER USEONLYController Notes:1)Provideinformation verballywhenappropriate actionsaresimulated orinvestigations aremadebytheAuxiliary Operators senttoisolatethe"A"S/GARV.AnticiatedResults:1)AsperMini-Scenario Anticipated Results.g-32

~GINN4TATIDNJ1992EVALUATED EXERIEMINI-SCENARIO Ac1~iviy:Isolation of"A"S/GARVandsteamleakdetection onthe"B"S/GARV.FORCONTROLLER USEONLY1)EnsureAuxiliary Operator(AO)simulates closingmanualvalve3507("A"S/GARVIsolation Valve).AfterAOcompletes simulating theisolation ofthe"A"S/GARV,butpriortoinforming theControlRoom,Controller mustnotifySimulator ControlBoothOperatoratExt.6641thatthevalveisisolated.

~lnf~rtheAOthatthe"B"S/GARVinletsteamlinehasamoderateleakonitbetweentheARVandtheisolation valves(seeattachedsketch).2)EnsureAOsimulates checkingmanualvalve3507A("A"S/GARVIsolation Valve,BypassValve)closed.3)4)IftheControlRoomrequeststheAOtoisolatethe"B"S/GARV,afterbeinginformedoftheleak,usethe"Isolation of'8'/GARV"Mini-Scenario.

ANTICIPATED RESULTS1)AOshouldsimulateisolating the"A"S/GARV.2)AO,aftersimulating theisolation ofthe"A"S/GARVandbeinginformedofthe"B"S/GARVsteamlineleak,shouldinformControlRoomoftheisolation andleak.

ROCHESTER GASANOEI.ECTRIC CORPORATION GINNASTATION'OB:

SkmrC~cDATE'Zg@y5(gg~g.gg~MADEBY:PAGEOF Time:~7~Message:7INNATATION12EVALUATED EXERIE~MEEREFORMMMfL:RFfTRRfgdFffg"R"E/GERTMfdproblem.SirnuladPlanCniin:SeeAttachedMini-Scenario

~IVlessee:M<<MTHISISANEXERCISE>>""

FORCONTROLLER USEONLYController Notes:1)Provideinformation verballywhenappropriate investigations aremadebytheRepairTeam.AnticiaedResults:1)AsperMini-Scenario Anticipated Results.

GINNASTATION1992EVALUATED EXERCISEMINI-SCENARIO Ac1~iviy:Inadvertent LiftingofARV-3411-"A"S/GARVMercoidControlProblemRepairTeam(Checking ProblemandRepair).InitialConditions:

MethodofInitiation:

LoudnoiseheardinControlRoomandthroughout plant.ARV-3411openlightlit;closedlightextinguished.

Indications:

ARV-34111.Controller outputlevelreadszero.2.Openlightlit.3.Closedlightextinguished.

4.Computeralarm.ExpectedSequenceofActions:1.Operations manuallyisolatesARV-3411.

2.I/Cwillbecalledintotroubleshoot andrepair.3.I/Cshouldmonitorthefollowing:

-HC-468outputmeteratzero,-ARV-3411valvepositioner:

Inputsignalat2psiOutputpressureat0psi-Solenoid3411Senergized;

-PS-2092hasmercuryintripposition.

4.I/Cshouldreplacemercoidswitchwithspare.FinalCondition; I/Creplacesandcalibrates PS-2092.TurnsovertoOperations forfunctional check.

Time:0800Message:8GINNASTATION1992EVALUATED EXERCISEMESSAGEFORM8I<<CIRSimulated PlanConditions:

SEEATTACHEDSHEETS~essacee:

"""THISISANEXERCISE"""

FORCONTROLLER USEONLYController Notes:AnticiatedResults:1)Operators shouldbeperforming theapplicable actionsofthefollowing procedures:

a)0-6.10(PlantOperation withSteamGenerator TubeLeakIndication).

b)0-2.1(Normalshutdowntohotshutdown).

c)S-3.3C(H2or0,RemovalfromPrimarySystembyBurpingVolumeControlTankwithN,)d)S-3.3D(CVCSCationDemineralizer BEDoperations usingDeborating DlAUnit).2)ThePlantManager,Operations Assessment ManagerandDutyEngineershouldbemanningtheTSCforoffsiteCommunications assistance perEPIP1-5.8-36 199P'EVALUATED EXERCISETime:~'bOMAZORPAEVLHETERS ReactorShutdown~YES~ON-31OCPSN-32OCPSN-35'I~OSAMPSN-36CW-AMPSAvg.NuclearPowerRCSPressure~2.S.CPSIGPRZRLevel9~7ARCP'NNIGSTOPPEDBRCPRUNNGSTOPPED1AS/GLevel1BS/GLevel~.I0lAS/GPressure~'~PSIG1BS/GPressurePSIGTurbine/Generator NOFFLINEENGINEERED SAFEGUARDS HihHeadS.I.PumsFI-924OGPMFI-9250GPM1A.INSERVBOOS1B.INSERVTBOOS1'NSERVTBOOSBASTLevel=LowHeadS.I.PumsFI-626OGM1A.INSERVOOSRECIRC1B.INSERVTBOOSRECIRCRWSTLevel=Containment SraPums4KVBusesRGIZEDDEENERGIZED 48OVBusesNERGIZDEENERGIZED DCBatteries A$54VOLTSB/SOVOLTS nmtPressure~bloPSIGnmtSumpALevel~FEETCnmtSumpBLevelINCHESALoopHotLeg~i+7OFALoopColdLeg53'47OFBLoopHotLeg9OFBLoopColdLeg9.OFRVLIS*CET~.3OFS/GATotalAuxFWFlowOGPM9/GBTotalAuxFWFlowOGPMDIESELGENERATORS A.RUNNINGUNLOADEDSTBOOSB.RUNNINGUNLOADEDSBOOSTSCRUNNINGUNLOADEDSTBYOOSSecurityRUNNINGUNLOADTBOOSFI-931AOGPMFI-931B2)GPlA.INSERVTBOOS1B.INSERVTBOOSNaOHTankLevel=Containment ecircFans1A.SESTBYOOS1B.NSERSTBYOOS1C.INSEVBOOS1D.SESTBYOOSPostAccidentDampersOPENLOSEServiceWaterPums1A.SERVSTBYOOS1B.NSESTBYOOS1C.NSERVSTYOOS1D.INVSTBOOSA&BHeaderPressure8PSZGComonentColinWaterPums1A.STOOS1B.INSERVTOOSSurgeTankLevel=~'GENGINEERED SAFEGUARDS StandbAux.FeedaterPums1C.INSERVTBOOS1D.INSERVTYOOSAux.Feedwater Pums1A.INSERVTBOOS1B.INSERVTBOOSTurb.DrivenNSERVSTBOOSSTLevel~~FE*CET,=AverageofSelectedCoreExit,Thermocouples

'

OCT8i199207:59R.E.GINASINULATOR TRENDGROUPASSIGHNEI(T SUGARYPA6E1GROUP:EVENT1PROCEDURE:

EPIP1-5POINTIDKSCRITIONPLANTSTATUSE.U.1235678910ll12131415161718192021222324252627282930313233343536373839404142434446474849505152ATKiRXTN31N32N35N36NPPRCSLPZRFR("AFRCLBRXT16RXT17TSUBTCLSBALSBBPSBAPSGBGENBKRlGENBKR2BUS11ABUS11BBUS12ABUS12BB11A12AB11B12BPCVLS(IPAL0942EL0943EL0942DL0943DL0942CL0943CL0942BL0943BL0942AL0943AT0409AT0410AT0450T0451TAVBAMIDTAVBBWIDLRVTCCOREFAUXFWAFAUXFMBBKR081BKR082V3505V3504ANTICIPATED TRAHSIEHT M/0SCRANREACTORTRIPBREAKERSTATUSSONCERANGEDETECTORN-31SIKERANGEDETECTORN-32INTERNEDIATE RANGEDETECTORN-35INTERNEDIATE RANGEDETECTORN-36AVERAGENUCLEARPOWERREACTORCOOLANTSYSTENAVGPRESSPRESSURIZER AVERAGELEVELREA"TORCOOLANTLOOPAAVGFLOWREACTORCOOLNTLOOPBAVGFLOWRCPABREAKERCRUSERXTRIPRCPBBREAKERCAUSERXTRIPINCORETCSUBCOOLED NARBINSTNGENRNARROWRANGEAVGLEVELSTNGEHBNARROWRANGEAVGLEVELSTNGENAAVERAGEPRESSURESTNGENBAVERAGEPRESSUREGBERATORONLINEBREAKERlG1372GENERATOR GNLINEBREAKER9X1372BUSliASUPPLYBREAKERBUS11BSUPPLYBREAKERNOTTERNINATED Ot(PPCS(7/19/91)

NOTTERNIHATED ONPPCS(7/19/91)

BUS11ATO12ATIEBRENERBUS1lBTo12BTIEBRENERCOHTAINNENT AVERAGEPRESSURECONTAIN)(ENT SUNPAAVEImBELEVELSSPBLEVEL8INCHES(TRAINA)SU)PBLEVEL8INCHES(TRAINB)SU)PBLEVEL78INCHES(TRAINA)SNPBLEVEL78INCHES(TRAINB)SU@BLEVEL113INCHES(TRAIN A)SU%'LEVEL113INCHES(TRAIN B)SU%'LEVEL180INCHES(TRAIN A)SSPBLEVEL180INCHES(TRAIN B)SSPBLEVEL214INCHES(TRAIN A)SSPBLEVEL214INCHES(TRAIN B)RCLRHOTLEGTENPERATUlK'CLB HOTLEGTENPERATURE RCLACOLDLEGTEIIPERAT(SE RCLBCOLDLEGTENPERAT(HE RCLATAVG(THOT/TCOLD WIDERHB)RCLBTAVG(THOT/TCOLD WIDERNG)REACTORVESSELAVERAGELEVELEl.1INCORETCAVERA6ETENiPS/GATOTALAUXFEEDWATER FLOPS/6BTOTALAUXFEEDWAMaFLOWNTRAUXILIARY FEEDMRTER PU)IPANTRAUXILIARY FEEDMATER PUNPBAUXFMPUIFSTENISUPPLYVALVEAAUXFMPUNPSTEANSUPPLYVALVEBNOATMSHQTTRIP1.00000+00 1.000NMO7.01454-04 6.51626M98.612263.44.798.997.8NOTTRIPNOTTRIP47.852.252.1666.668.NOTTRIPNQTTRIPNOTTRIPHOTTRIPNOTTRIPNOTTRIPTRIPPEDTRIPPED~061~8Lo)IERLO)IERLG)E'ERLONERLOWERLONERLOWERLONERLONERLONER598.7598.7539.9541F6569.3570.299.5602.30.0.OFFOFFCLOSEDCLOSEDGGGD600DINHBIHHBINHBINHB6009HMRNGOOD6009600DGOOD6009600<<600960096009GOODGGQDGOODGOOD6009DELDEL600960096009GOODGOODGOODGOOD60096009GOODGOOD6009600960096009GGGDGOOD600960096009GOOD600<<6009GQGD60096009GOOD6009CPSCPSANPANP/PSIGXI/XKGF>/7.PSIGPSIGKBFK6FKGFDE6FKGFKGFDEGFPNGPN 0

OCTGs199207:59R.E.GINASltiULATOR TRENDGROUPASSIGtttiENT SUtitiARY PAGE253FSIA54FSIB55P216056P216157BKR04158BKR04259BKR04360BKR044SAFETYINJECTION LOOPAAVGFLOMSAFETYINJECTION LOOPBAV6FLOMSERVICEMATERPlIPSAhBHEADERSERVICEMATERPNPSC5DHEADERSERVICEMATERPNiPASERVICEMATERPUtiPBSERVICEMATERPlIPCSERVICEMATERPUtiPD6ROUP:EVEt)TIPROCEDURE:

EPIP1-5POINTIDDESCRIPTION PLAtlTSTATUSVALLEY0.0.81.73.ONONONOFFQUALE.U.GOODG.VGOODIFNGOODPS16GOODPSIGGOODGOODGOODGOODEMJ

~~~GRAMNAME:LRGTSZ.E

.E.GlkkANUCLEARPOWERPLANTOCT08,9208:00:00TRENDGROUPASSIGNHEHT SUMMARYGROUPkAMEEVENT2GROUPDESCRIPTIONPROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURREHTVALUEQUALITYCODEEHGRUNITS1235678910111213142021222425262728293031323334353637383940414243-F0619LRWSTWS033W0033WT033WT250WDT2R01R02R05R09R34R35R10AR11R12R10BR13R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14A5R14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03TCV07TCVOBTCV09TCV10TCV17COMPOHENT COOLINGLOOPTOTALFLWREFUELIHG WATERSTORAGETANKLVL33FOOTLEVELWIHDSPEED33FOOTLEVELWINDDIRECTIOH 33FOOTLEVELTEMPERATURE 250FOOTLEVELTEHPERATURE 250TO33FOOTLEVELDELTATEMPAREA1-CONTROL ROOMAREA2-CONTAINMENT AREA5-SPENTFUELPITAREA9-LETDOWN LINEMOHITORAREA34-AUXBLDGCVSPRAYPUMPAREA35-PASSSAHPLEPANELCONTAINMENT IODINEMONITORR10ACONTAINMENT AIRPARTICULATE CONTAINMENT GASMONITORPLANTVENTIODIHEMONITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIQUIDWASTEDISPOSALMOHITORSTEAMGENERATOR SLOWDOWNDRAINAREA29-CONTAINHEHT HIGHRAHGEAREA30-CONTAINHEHT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LOWRANGEGASCVVENTCHAN6-AREAGAMMACVVENTCHAN7-HIDRANGEGASCVVENTCHAN9-HIGHRANGEGASPLANTVENTCHAN5-LOWRAHGEGASPLANTVENTCHAk7-MIDRANGEGASPLANTVENTCHAN9-HIGHRANGEGASAIREJECTORCHAN5-LOWRANGEGASAIREJECTORCHAN7-MIDRANGEGASAIREJECTORCHAN9-'HlRANGEGASAREA31STEAMLINEA(SPING)AREA32STEAMLINE8(SPING)CVHYDROGENCONCENTRATION CVBASEMENTLVL6FTTEMP¹3CVINTERMEDIATE LVL6FTTEMP¹7CVINTERMEDIATE LVL6FTTEHP¹8CVINTERHEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEMP¹10CVOPERATING LVL6FTTEMP¹171485~94.53.6222.57.758.00.39.02214-02 6.40678+00 1.39946+00 3.40701+01 9.09354-01 1'9283+009.58719+01 5~18901+027.38002+02 4.30543t01 8.58327+01 4.22831+01 2.78658i03 4.07174+03 5.05861-01 5.09440-01 1.25835+05 1.89699.07 2.53990-02 3.57435-05 1.41261-03 4'0312-076.86543-05 3.72621-03 6.29179-03 6.29392-03 6.29436-03 1.02040.02 1.01048-02

.095.1106.0106.6106.7106.2117.5GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOODGOODGOODHALHHWRNGOODGOODGOODGOODGOODGOODGOODGPMMPHDEG.DEGFDEGFDEGFHR/HHR/HMR/HMR/HMR/HMR/HCPHCPMCPMCPHCPMCPMCPMCPMR/HRR/HRCPMUCI/CCHR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRHR/HRXDEGFDEGFDEGFDEGFDEGFDEGF Time:~~1Message:~GINNASTATION12EVALATEDEXERIEMESSAGEFORMf:AillYOp<<iI1'B"S/GARVSimulaedPlnCondiion:SeeAttachedMini-Scenario

~ll/lesss

<<<<<<THISISANEXERCISE"""

FORCONTROLLER USEONLYController Noes:1)Provideinformation verballywhenappropriate actionsaresimulated bytheAuxiliary Operatorsenttoisolatethe"8"S/GARV.AniciatedResults:1)AsperMini-Scenario Anticipated Results.

GINNASTATION1992EVALUATED EXERCIEMINI-CENARIAct~iviy:Isolation of"B"S/GARVFORCONTROLLER USEONLYController Notes:1)EnsureAuxiliary Operator(AO)simulates closingmanualvalve3506("B"S/GARVIsolation Valve).2)EnsureAOsimulates checkingmanualValve3506A("B"S/GARVIsolation Valve,BypassValve)closed.3)Theiolainofh"B"SGARVmusecnsidredonendrConrolRoomSrir1045.AnticiatedResults:1)AOshouldsimulateisolating the"B"S/GARV.2)AOshouldinformtheControlRoomofthe"B"S/GARVisolation.

Time:0815Message:~1GINNASTATION192EVALUATED EXERCISEMESSAGEFORM~f:8I<<R<<IRSimulaedPlantConditins:SeetheAttachedSheets~Massee:"""THISISANEXERCISE"""

Thefollowing annunciators arereceived:

~G-22(ADFCSSystemTrouble)FORCONTROLLER USEONLYController Notes;1)Whenoperators checktheControlBoard,informthemthatthe"MFWRegValvesarecontrolling andallControlBoardindications arenormal.AnticiatedResults:1)Operators shouldperformtheapplicable actionsofAR-G-22andER-INST.1.

2)Operators shouldchecktheS/Glevelstoensureproperlevelcontrol.3)Operators shouldsimulatecheckingtheADFCSPrinterforcauseoffailure(ADFCSprinterreadoutonattachedMini-'Scenario).

4)Operators shouldinformthepeoplemanningtheTSCandISCDepartment oftheADFCSproblem.5)Operators shouldinformpeoplemanningtheTSCofthe"B"S/GARVlinesteamleak.

Time:~8~1Message:~1Qgn~ingg6)Operators mayrequestAuxiliary Operatortoisolatethe"B"S/GARV.7)Operators shouldinformthepeoplemanningtheTSCofthe"A"S/GARVproblemandisolation.

8)Operators continueshuttingthePlantdownper0-2.1.9)PeoplemanningtheTSCmayrequestthe"B"S/GARVbeisolategrmaywaituntilMaintenance personnel haveinspected it.10)PeoplemanningtheTSCamyinformControlthattheywilltakeactionstohaveMaintenance personnel inspectforthe"A"and"B"S/GARVproblems.

199<'VALUATED EXERCISETime:05'l5MAJORPAT%METERS ENGINEERED SAFEGUARDS ReactorShutdownN-31N-32N-35N-36Avg.NuclearPowerRCSPressurePRZRLevelARCPUNNBRCPUN1AS/GLevel1BS/GLevellAS/GPressure1BS/GPressureTurbine/Generator ONL4KVBusesERGIZ480VBusesRGIZDCBatteries A~SaVOLTS CnmtPressureCnmtSumpALevelCnmtSumpBLevelALoopHotLegALoopColdLegBLoopHotLegBLoopColdLegRVLIS*CETS/GATotalAuxFWFlowS/GBTotalAuxFWFlowYES0~CPSCPSAMPSAMPSPSIGINGSTOPPEDNSTOPPED~e3PSIG.0PSIGFFLINEDEENERGIZED DEENERGIZED B($0VOLTS.o6PSIG~FEET~gINCHES~feZOF~ST&OFOFmmkoF~1~0GPMO'PMDIESELGENERATORS OOSAux.Feedwatems1A.INSERVOOS1B.INSERVTBOOSTurb.DrivenINSERVSTBOOSCSTLevel~~FA.RUNNINGUNLOADEDTOOSB.RUNNINGUNLOADEDOOSTSCRUNNINGUNLOADEDTOOSSecurityRUNNINGUNLOADEDTBENGINEERED SAFEGUARDS HihHead-S.I.PumsFI-924GPMFZ-925~GPM1A.INSERVTOOS1B.INSERVTBOOS1C.INSERVBOOSBASTLevel=LowHeadS.I.PumsFI-6260GPM1A.INSERVTBOOSRECIRC1B.INSERVTBYOOSRECIRCRWSTLevel=Containment SraPumsFZ-931A~GPM FI-931B~GPM 1A.INSERVSB1B.INSERVTBNaOHTankLevel=OOSOOSContainRecircFans1A.NSESTBYOOS1B.NSESTBYOOS1C.INVTBOOS1D.SERSTBYOOSPostAccidentDampersOPENLOSDServiceWatePums1A.SESTBYOOS1B.NSESTBYOOS1C.NSESTBYOOS1D.INSERVTBOOSA&BHeaderPressure~PS1GComonentCoolinWaterPums1A.SERSTBYOOS1B.INSERVTBOOSSurgeTankLevel=~'oStandbAux.FeewaterPums1CINSERVBOOS~1D.INSERVTBOOS*CET=AverageofSelectedCoreExitThermocouples

Gi199208:14R.E.GINASIMULATOR TRENDGROUPASSIGISTSUtIARYPAGE1GROUP:EVENT1PRXEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION VALUEE.U.1234'5678910il1213141516171819202122232425262728293031323334353637383940414243444546474849505152ATt6RXTN31N32N35N36NPPRCSLP2RFRCLAFRCLBRXT16RXTDTSUBTCLSGALS68PSGAPSGBGENBKRlGENBKR2BUSliABUS118BUS12ABUS128811A12A8118128PCVLSNPAL0942EL0943EL0942DL0943DL0942CL0943CL09428L09438L0942AL0943AT0409AT0410AT0450T0451TAVGAMIDTAVBBWIDLRVTCCOREFAUXFMAFAUXFMBBKR081BKR082V3505V3504ANTICIPATED TRANSIENT M/0SCRAMREACTORTRIPBREAKERSTATUSSolSCERANGEDETECTORN-31SO(SCERAt(GEDETECTORN-32INTERMEDIATE RANGEDETECTORN-3SINTERMEDIATE RANGEDETECTORN-36AVERAGENUCLENPOWERREACTORCGOUITSYSTEMAVGPRESSPRESSURI2ERAVERAGELEVELREACTORCOOLA%'OOP AAVGFLOWREACTORCOOLANTLOOP8AVGFLOWRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCGRETCSUIG)GLED NARiINSTMGENANARROWRANGE,AVG LEVELSTMGEN8NARROWRANGEAVGLEVELSTMGENAAVERAGEPRESE)RESTM6EN8AVERAGEPRESSUREGYRATORONLINEBREAKER161372GBERATORONLINEBREAKER9X1372BUS11ASUPPLYBREAKERBUS118SUPPLYBREAKERt<OTTERMINATED 0)IPPCS(7/19/91)

NGTTERMII(ATED ONPPCS(7/19/91)

BUS11ATO12ATIEBRENERBUS118TQ128TIEBRENERCOt(TAINMENT AVERAGEPRESSURECONTAINMENT SUMPAAVERAGELEVELSUIP8LEVEL8INCHES(TRAINA)SUIP8LEVEL8INCHES(TRAIN8)SUIP8LEVEL78INCHES(TRAINA)SU)P8LEVEL78INCHES(TRAIN8)SU)P8LEVEL113INCHES(TRAIN A)SUtP8LEVEL113INCHES(TRAIN 8)SU)P8LEVEL180INCHES(TRAIN A)SUtP8LEVEL180INCHES(TRAIN 8)SU)P8LEVEL214INCHES(TRAIN A)SIP8LEVEL214INCHES(TRAIN 8)RCLAHOTLEGTEMPERATUfK RCLBHOTLEGTEMPERATURE RCLACOLDLEGTE)IPERAT(HE RCLBCOLDLEGTE)IPERAT(SE RCU)TAVG(THOT/TCOI.D WIDERNG)RCLBTAVG(THGT/TCGLD WIDERNG)REACTORVESSELAVERAGELEVELEi.lINCORETCAVERAGETEMPS/6ATOTALAUXFEHIATERFLOMS/68TOTALAUXFEEDMATER FLOWMTRAUXILIARY FEEDNATER PlNPAMTRAUXILIARY FEEDMATER PlNP8AUXFMPU)PSTEA)ISUPPLYVALVEAAUXFMPUI(PSTEA)ISUPPLYVALVE8NoATNNOTTRIP1.00000+00 1.00000+00 6.66807M6.16593M93.562264.47.998.497.3NOTTRIPNOTTRIP47.9S2.052.1703.701.NOTTRIPNGTTRIPNOTTRIPNOTTRIPNOTTRIPNOTTRIPTRIPPEDTRIPPED.061.8LONERLOWERLOWERLONERLONERLONERLOWERLOWERLONERLONER599.2599.2543.5544.8571'572.099.3602.60.0.OFFOFFCLOSED,CLOSED600DGOODINH8CPSINHBCPSINHBAMPINHBAMP60096000PSIGBoon/6009KGGGD/60006000GooeKGFBoon/60006009psiGGOODPSI66009600DGOOD6000DELDELGoonGOOD600DPSIG6009FEET6000GoonGoon6000GOOD6000GOODGoon6000BGGD6009DEGF600DDEGFBGGDDE6F6000DEBFBoon9GFGOODDEGFGOOD/BooeDEGFGOODGPM60006PMGOODGGGDGGGD6000 OCT8~199208:14R.E.GINAS1%LATORTRENDGROUPASSIGNMENT SUtDIRYPAGE26ROUP:EVM'IPRXEDURE!

EPIP1-5PLAftTSTATUSPOINTIDDESCRIPTION VALLEYDUALE.U.53FSIA54FGIB55P216056P216157BKR04158BKR04259BKR04360BKR044SAFETYINJECTION LOOPAAVGFLOWSAFETYINJECTION LOOPBAVGFLOWSERVICEMATERPfIPSAhBHEADERSERVICEWATERPUffPSC5DHEADERSERVICEWATERPUffPASERVICEMATERPUNPBSERVICEWATERPUtfPCSEfNICEMATERPUtfPDONONONOFF0.0.82.730GOODPNGOODGPNGOODPSIGGOODPSIGGOODGOOD600DGOOD OGRAMNAHE:LRGTSZ.E R.EDGINNANUCLEARPONERPLANTOCT08,9208:15:00TRENDGROUPASSIGHHENT SUHHARYGROUPNAMEEVENT2GROUPDESCRIPTIOHPROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURRENTVALUEQUALITYCODEENGRUNITS12345678910111213141519202122232425262728293031323334353637383940414243-F0619LRMSTMS033MD033MT033llT250lST2R01R02R05R09R34R35R10AR11R12R108R13R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14A5R14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03TCV07TCVOBTCV09TCV10TCV17COMPONENT COOLINGLOOPTOTALFLllREFUELIHG MATERSTORAGETANKLVL33FOOTLEVELlllNDSPEED33FOOTLEVELMINDDIRECTION 33FOOTLEVELTEMPERATURE 250FOOTLEVELTEMPERATURE 250TO33FOOTLEVELDELTATEMPAREA1-CONTROL ROOMAREA2-CONTAINMENT AREA5-SPENTFUELPITAREA9-LETDSNLINEMONITORAREA34AUXBLDGCVSPRAYPUMPAREA35-PASSSAMPLEPAHELCOHTAIHMENT IODINEMONITORR10ACONTAINMENT AIRPARTICULATE CONTAINMENT GASMOHITORPLAHTVENTIODINEMOHITORR'IOBAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIQUIDIIASTEDISPOSALMONITORSTEAMGENERATOR BLOSOMHDRAINAREA29-CONTAINMEHT HIGHRANGEAREA30-COHTAINHEHT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LOWRANGEGASCVVENTCHAN6-AREAGAMMACVVENTCHAN7-MIDRANGEGASCVVENTCHAH9-HIGHRANGEGASPLANTVENTCHAN5-LOURAHGEGASPLANTVENTCHAN7-MIDRAHGEGASPLANTVENTCHAN9HIGHRANGEGASAIREJECTORCHAN5-LOWRANGEGASAIREJECTORCHAN7-MIDRANGEGASAIREJECTORCHAN9-HIRANGEGASAREA3'ISTEAMLINEA(SPING)AREA32STEAMLINEB(SPING)CVHYDROGENCONCENTRATION CVBASEMEHTLVL6FTTEMP¹3CVINTERMEDIATE LVL6FTTEMP¹7CVINTERMEDIATE LVL6FTTEMP¹8CVINTERHEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEMP¹10CVOPERATING LVL6FTTEHP¹171485.94.53.6194.58.758.0.0.79.02214-02 6.40678+00 1.39946i00 3.40701+01 9.09354.01 1.09283+00 9.58719+01 5.18901+02 7.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658i03 4.07174+03 5.05861-01 5.09440.01 1.25835+05 1.89699.07 2.53990-02 3'7435-051.41261-03 4.40312-07 6.86543.05 3.72621-03 6.29179.03 6.29392-03 6.29436-03 1.02040.02 1.01048.02

.095.1106.0106.6106.7106.2117.5GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOODGOODGOODGOODHALMHNRHGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGPHMPHDEG.DEGFDEGFDEGFMR/HMR/HMR/HMR/HMR/HMR/HCPMCPMCPMCPMCPMCPMCPMCPM'/HRR/NRCPMUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRMR/HRxDEGFDEGFDEGFDEGFDEGFDEGF Time:~$15Message:11GINNASTATIN192EVALUATED EXERIE~MEAEFRM~f:E'EIGAIIEM Mkk~FfTSimulated PlantCondiions:SeeAttachedMini-Scenario

~Messe:<<""THISISANEXERCISE"""

FORCONTROLLER USEONLY~GIIR1)Provideinformation verballywhenappropriate investigations aremadebythe"B"S/GARVLineSteamLeakRepairTeam.AnticiaedResults:2)AsperMini-Scenario Anticipated Results.

GINNASTATION1992EVALUATED EXERCISEMINI-SCENARIO Ac1~iviy:"B"S/GARVLineSteamLeakInvestigation andRepairInitialConditions:

SteampressureatMainSteamHeaderperscenario.

MethodofInitiation:

Aux.Operatorobserving conditions inarea,notifiesControlRoomofsteamleakinthelocationofthe"B"SteamHeader.'ndications:

Largeamountofsteamattheflangeareaof"8"S/GARV,SteamcomingfromholedrilledinweldandinletflangeleadingtovalveAOV-3410(seeattachedsketch).ExpectedSequenceofActions:1.NotifyTSCMaintenance supportgroup,2.PipeShopPlanner/Welder notified.

3.PipeShopPlanner/Welder investigate forrepairs.4.Initiatepackagesforrepairs.5.Pipefitter/Welders crewssentouttomakerepairs.6.Repairscompleted andservicerestored.

FinalCondition:

NotifyTSCofcompletion ofmaintenance andremoveholdsfortestingandreturntoservice.

GINNASTATION:lOB:SA'&7GHoROCHESTER GASANOELECTRlCCORPORATlON DATE:MADEBY:4%140SPAGEOF Time:~~1Message:~2NINNASTATION12EVALUATED EXERIEMESSAGEFORMSSNNNLIAL:

MFFNNNIIIIVIIADFNSTSlINSITIPnii:SeeattachedMini-Scenario

~Mesce:"""THISISANEXERCISE"""

FORCONTROLLER UENLY~CIIN1)Provideinformation verballywhenappropriate investigations aremade.2)Controller mustnotifySimulator ControlBoothOperatoratExt.6641tocoordinate actionsassociated withthisMini-Scenario.

AnicieReIts:1)AsperMini-Scenario anticipated results.

ROCHESTER GASANDELECTRICNIINNATTlNMINISCENARIOTITLE:INITIALCONDITIONS:

ADFCSTroubleG-22InAlarmGraphicsshowthatQAMonleftblockas"BACKUPROLE"onayellowbackground andQAMontherightblockas"PRIMARYROLE"onagreenbackground.

METHODOFINITIATION:

Programsimulator togiveannunciator 6-22.INDICATIONS:

AtADFCSPrinterintheMUXRoomwillprintoutthefollowing messages:

1)DateTimeDIGITALSCANALARMADFCSTRBADFCSSYSTEMTROUBLEANNUNC.~2)DateTimeDIGITALSCANALARMK10FCVARELAYK1OPENEDFCVAGraphicsshowthatQAMonleftblockas"PRIMARYROLE"ongreenbackground andQAMonrightblockas"BACKUPROLE"onyellowbackground.

Thefollowing errormessageswillbeseenonthegraphicsdisplay:7.Switchover defeated.

(Switchover triggerislatched.Resettriggerwhenswitchover demandhasbeencleared).

11.Possibledefective K1relayorQCIinput.ReplacerelayK1whenA/Alogic=0.EXPECTEDSEQUENCEOFACTIONS:~Notifymaintenance supportgroup~ISCPlannerreceivesT.R.~ISCPlannerinvestigates T.R.~IRCTechnicians gotoMaintenance TrainingSystemtoreplacedefective K1relay~ClearallalarmsFINALCONDITIONS'otify Simulator ControlRoomthatmaintenance iscomplete.

Time:~39Message:~1Nll~NANTTlN192EVALUATED EXERIEMESSAEFRMNle~f:NiI<<C<<INSimulated PlantConditions:

SeetheAttachedSheets~Messe:<<<<<<THISISANEXERCISE"""

FORCONTROLLER USEONLY~CIIN1)ACCWSystemleakof20gpmstartsatthistime.Theleakisonthe1ACCWPumpmechanical seal~AnticiaedResuls:1)Operators continueshuttingthePlantdownper0-2,1, 199ZEVALUATED EXERCISETime:0F3OENGINEERED SAFEGUARDS HihHeadS.I.PumsMAJORP2Q&METERS FI-924OGPMFI-925~GP1A.INSERVTBOOS1BINSERVTBOOS1C.INSERVTBOOSBASTLevel=LowHeadS.I.PumsFI-626OGM1A.INSERVTBOOSRECIRC1B.INSERVTBOOSRECIRCRWSTLevel=Containment SraPumsFI-931A0GPMFI-931B~GPM 1A.INSERVTBOOS1B.INSERVTBOOSNaOHTankLevel=ContainmecircFans1A.SESTBYOOS1B.NSERSTBYOOS1C.INSERVBOOS1D.SSTBYOOSPostAccidentDampersOPENLOSEDServiceterPums1A.NSESTBYOOS1B.STBYOOS1C.NSESTBYOOS1D.INSRVBOOSA&BHeaderPressureDIESELGENERATORS A.RUNNINGUNLOADEDBOOSB.RUNNINGUNLOADEDTBOOSTSCRUNNINGUNLOADEDTBOOSSecurityRUNNINGUNLOADEDTB8PSIGComonenCoolinWaterPums1A.NSERSTBYOOS1B.INSERVSTBOOSSurgeTankLeve=SOOOSENGINEERED SAFEGUARDS, ReactorShutdownYES~@N-31OCPSN-32C7CPSN-35AMPSN-36AMPSAvg.NuclearPowerRCSPressure2.X.LZPSIGPRZRLevelARCPSTOPPEDBRCPUNNINGSTOPPED1AS/GLevel~z.I1BS/GLevel~..I1AS/GPressurePSIG1BS/GPressureo7PSIGTurbine/Generator NLIOFFLINE4KVBusesERGIZDEENERGIZED 480VBusesERGIZEDDEENERGIZED DCBatteries A/SOVOLTBISOVOLTSCnmtPressure~<~PSIGCnmtSumpALevel~FEETCnmtSumpBLevelINCHESALoopHotLeg9OFALoopColdLeg~$.OFBLoopHotLegOFBLoopColdLegOFRVLIS*CET40.3OFS/GATotalAuxFWFlowGPMS/GBTotalAuxFWFlow0GPMAux.FeedwatePums1A.INSERVOOS1B.INSERVTOOSTurb.DrivenNSERVTBOOSCSTLevel2.FEStandbAux.FeedaterPums1C.INSERVOOS1D.INSERVTBOOS*CET=AverageofSelectedCoreExitThermocouples 8~199208:30R.E.GIM(ASit(ULATOR TRENDGROUPASSIGNNENT SUt(MYPAGE16ROUP:EVENT1PROCEDURE'PIP 1-5PLANTSTATUS1234678910if12131415161718f920252627282930313233343536373839404142434445465152POINTIDATMSRXTN31N32N35N36NPPRCSLPLRFRCLAFRCLBRXTI6RXT17TSUBTCLSGALSGBPSGAPSGBGENBKR1GENBKR2BUS11ABUSflBBUS12ABUS12BBlfA12AB119129PCVLSI(PAL0942EL0943EL0942DL0943DL0942CL0943CL0942BL0943BL0942AL0943AT0409AT0410AT0450T0451TAVGAMIDTAViiBWID TCCGREFAUXFMAFAUXFWBBKR081BKR082V3505V3504DESCRIPTION ANTICIPATED TRANSIEhT M/0SCRAt(REACTORTRIPBREAKERSTATUSSONCERANGEDETECTORH-31SGNCERAt(GEDETECTORN-32INTER)(EDIATE RANGEDETECTORN-35INTER)(EDIATE RANGEDETECTORN-36AVERAGENUCLEARPOWERREACTORCGOUt(TSYSTBIAVGPRESSPRESSURIIERAVERAGELEVELREACTORCOOLANTLOOPAAVGFLOWREACTORCOOLANTLOOPBAVGFLQMRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCORETCSUBCOQLED HARBINSTt(GEt(ANARROWRANGEAVGLEVELSTNGENBNARROWRANGEAVGLEVELSTNGEt(AAVERAGEPRESSURESTNGEHBAVERAGEPRESSUREGBGQTGRONLINEBREAKER161372GYRATORONLINEBREAKER9X1372BUS11ASUPPLYBREAKERBUS11BSUPPLYBREAKERHOTTERt(INATED ONPPCS(7/19/91)

NOTTERNlt(ATED ONPPCS(7/19/91)

BUSllATo12ATIEBREWERBUS11BTO12BTIEBREAKERCOHTAINt(ENT AVERAGEPRESSURECQNTAItNENT SUt(PAAVERAGELEVELSUtPBLEVEL8INCHES(TRAINA)SU)PBLEVEL8INCHES(TRAINB)SU(PBLEVEL78INCHES(TRAINA)SU)PBLEVEL78INCHES(TRAINB)SU)PBLEVEL113INCHES(TRAIN A)SUlPBLEVEL113INCOMES(TRAIN B)SU(PBLEVEL180INCfKS(TRAIN A)SUtPBLEVEL180INCHES(TRAIN B)SUtPBLEVEL214INCHES(TRAIN A)SUtPBLEVEL214INCHES(TRAIN B)RCLAHQTLEGTE)(PERATUfK RCLBHOTLEGTEt(PERATSK RCLACOLDLEGTB(PERATNE RCLBCOLDLEGTE)(PERATURE RCLATAVG(THOT/TCOLD WIDERNG)RCLBTAVG(THQT/TCOLD WIDERNG)REACTORVESSELAVERAGELEVELEl.1INCORETCAVERAGETEMPS/6ATOTALAUXFEEIIAPDFL(IS/GBTOTALAUXFEEDWATER FLOWtmAUXILIARY FEEDMATER PUt(PAt(TRAUXILIARY FEEDMATER PUtPBAUXFMPUt(PSTEANSUPPLYVALVEAAUXFWPUt(PSTEANSUPPLYVALVEBVALUENOATWSNOTTRIPl.00000%01.005&006.48633M6.02558-04 91.192262.46,798.597.3NQTTRIPNGTTRIP49.552.152.1708.707.NOTTRIPNGTTRIPNOTTRIPNOTTRIPNQTTRIPNQTTRIPTRIPPEDTRIPPED.N1~9LOVERLONERLOVERLONERLOVERLONERLOVERLONERLOWERLOVER597.8597.8543.5544.8570.7571.399.4601.30.0.OFFOFFCLOSEDCLOSEDQUAL60096009INH9INHBINHDINH86009600960096009600960096009600~60096009600960096009GOOD6009GOODDELDEL6009600960096009600960096009GOOD600960096009GOOD600960096009GOOD60096009GOOD6009GOODGoo>60096009GGGD600960096009E.U.CPSCPSAt)PAt(P/IPSIGXy.7.KGF//IPSIGPSIGPSI6FryDEGFKGFKGFKGFDEGFK6FDE6FGPt(GPH OCT8i199208'30R.E.GINASItlULATOR TRENDGROUPASSIGtIENT SUNNARYPAGE26ROUP:EVEtlT1PRXEDURE:

EPIP1-5PLAtlTSTATUSPOINTID.DESCRIPTION VALLEY11ALE.U.53FSIA54FSIB55P216056P216157BKR04158BKR04259BKR04360BKR044SAFETYINJECTION LOOPAAVGFLOMSAFETYINJECTION LOOPBAVGFLOWSERVICEMATERPIIPSAhBHEADERSERVICEMATERPUtlPSChDHEADERSERVICEWATERPlNPASERVICEMATERPIPBSERVICEMATERPUtlPCSERVICEMATERPUtlPDONONONOFFO.GOOD0.GOOD82.GOOD73.GOODGOODGOODGOODGOODGPtlGPtlPSIGPSIG

~~~ROGRAMNAME:LRGTS2.E R.E.GINNANUCLEARPOWERPLANTOCT08,9208:31:00TRENDGROUPASSIGNHENT SUHHARYGROUPNAMEEVENT2GROUPDESCRIPTIOH PROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURRENTVALUEQUALITYCODEENGRUNITS1234567891011121314202122232425262728293031323334353637383940414243F0619LRWSTWS033WD033WT033WT250WDT2R01R02ROSR09R34R35R10AR11R12R108R13R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14A5R14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03TCV07TCV08TCV09TCV10TCV17COMPONENT COOLINGLOOPTOTALFLWREFUELING WATERSTORAGETANKLVL33FOOTLEVELWINDSPEED33FOOTLEVELWINDDIRECTION 33FOOTLEVELTEHPERATURE 250FOOTLEVELTEMPERATURE 250TO33FOOTLEVELDELTATEHPAREA1-CONTROL ROOHAREA2-COHTAINMENT AREA5-SPENTFUELPITAREA9-LETDOWN LINEMONITORAREA34-AUXBLDGCVSPRAYPUHPAREA35-PASSSAHPLEPANELCONTAIHMEHT IODINEMOHITORR10ACONTAINMENT AIRPARTICULATE CONTAINHENT GASMONITORPLANTVENTIODINEHOHITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMOHITORLIQUIDWASTEDISPOSALMONITORSTEAMGENERATOR BLOWDOWNDRAINAREA29-CONTAINHEHT HIGHRANGEAREA30-CONTAIHHENT HIGHRANGECONDEHSER AIREJECTOREXHAUSTCVVENTCHAN5LOWRANGEGASCVVENTCHAN6-AREAGAMMACVVENTCHAN7-MIDRANGEGASCVVENTCHAN9-HIGHRANGEGASPLAN'IVENTCHAN5-LOWRANGEGASPLANTVENTCHAN7-MIDRANGEGASPLANTVENTCHAN9-HIGHRANGEGASAIREJECTORCHAN5-LOWRANGEGASAIREJECTORCHAN7-HIDRANGEGASAIREJECTORCHAN9-HIRANGEGASAREA31STEAMLINEA(SPING)AREA32STEAMLINEB(SPING)CVHYDROGENCONCENTRATIOH CVBASEHENTLVL6FTTEMP¹3CVINTERMEDIATE LVL6FTTEHP¹7CVINTERMEDIATE LVL6FTTEMP¹8CVINTERMEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEMP¹10CVOPERATING LVL6FTTEHP¹171485.94.52.647.59.658.9.0.79.02214-02 6.40678+00 1.39946+00 3.40701+01 9.09354-01 1.09283+00 9.58719+01 5.18901+02 7.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658+03 4.07174+03 5.05861.01 5.09440-01 1.25835+05 1.89699-07 2.53990.02 3.57435-05 1.41261-03 4.40312-07 6.86543-05 3.72621.03 6.29179-03 6.29392-03

&.29436-03 1.02040-02 1.01048-02

.095.1106.0106.6'106.7106.2117.5GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOODGOODGOODGOODHALHHWRNGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGPMxMPHDEG.DEGFDEGFDEGFHR/HMR/HMR/HMR/HMR/HMR/HCPMCPMCPMCPMCPMCPMCPMCPMR/HRR/NRCPMUCI/CCKR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRMR/HRXOEGFDEGFDEGFDEGFDEGFDEGF Time:3@~4Message:14INNATATIN12EVALATEDEXERIEIVIEAEFRIVIMMMf:8I<<1:tRSimvladPlanConiin:~M~i~a"""THISISANEXERCISE"""

Thefollowing annunciator isreceived:

A-13(CCWSurgeTankLevel41.2%)FORCONTROLLER USEONLYConrollerNoe:1)Whenoperators checktheCCWSurgeTanklevelonControlBoard,Informthemthatitisapproximately 41%anddecreasing slowly.AnticiaedResults:1)Operators shouldperformtheapplicable actionsofAR-A-13.2)Operators shouldperformtheapplicable actionsofAP-CCW.2.

'I3)Operators shouldsendanAuxiliary OperatorintotheAuxiliary BuildingtoidentifytheCCWSystemleak.4)Operators shouldinformthepeoplemanningtheTSCoftheCCWleak.

Time:Jg~4Message:~5INNASTATIN12EVALUAEDEXEREMESSAGEFRM~llii:AiiiYOI<<Aili~Bildig identifytheCCWLeak.imulaePlanniin:SeetheAttachedMini-Scenario

~Maaae:"""THISISANEXERCISE"""

FRCONTROLLER USEONLYN1)Provideinformation verballywhenappropriate actionsaresimulated orinvestigations aremadebytheAuxiliary OperatorsenttotheAuxiliary BuildingtoidentifytheCCWleak.2)TheController mustnotifytheSimulator ControlBoothOperatortocoordinate allactionsassociated withthisMini-Scenario.

AniiRsI1)AsperMini-Scenario Anticipated Results INNATATIN12EVALUATED EXERISEMINI-SCENARIO

~A~Ivly:CCWLeakIdentification andIsolation ofthe1ACCWPumpFONTROLLER USEONLY~IIN1)W~hnAuxiliary Operatoriswithinviewingdistanceofthe1ACCWPump,~infrmhimthatthe1ACCWPumpmechanical sealisleakingandsprayingonthepumpmotor.2)~WhnAuxiliary Operatorisrequested toisolatethe1ACCWPump,answerthefollowing:

(a)EnsureAuxiliary Operatorsimulates closingmanualvalve724A(CCWPumpADischarge BlockVLV).(b)EnsureAuxiliary Operatorsimulates closingmanualvalve722A(CCWSuctionBlockVLVtoCCWPumpA).(c)EnsureAuxiliary Operatorsimulates rackingoutthe1ACCWPumpelectrical breaker(Bus'I4,Position23A).3)Whenpumpisisolated;.the Controller mustnotifytheSimulator ControlBoothOperatoratExt6641priortoallowingplayerstonotifytheControlRoom/TSC.

AniciadResIs:1)Auxiliary

Operator,

~whninformedofthe1ACCWPumpleak,shouldinformtheSimulator ControlRoom.2)Auxiliary

Operator,

~whnrequested, shouldsimulateisolating the1ACCWPump.3)Auxiliary

Operator, aftersimulating theisolation ofthe1ACCWPumpshouldinformSimulator ControlRoomoftheisolation.

Time:~~4~jMessage:~1INNATATIN12EVALATEDEXERIEMEAEFRM~NI:NI<<C<<IRSimlaPlanCondiion:SeetheAttachedSheets~Massa"""THISISANEXERCISE"""

FRCONTROLLER USEONLY~CIIN1)Whenoperators startfillingtheCCWSurgeTankwithRMUwater,informthemthatthelevelisstartingtoincreaseslowly.AnticiatedResults:1)Operators continueperforming applicable actionsofAP-CCW.2.

2)Operators continueshuttingthePlantdownper0-2.1.8 199K'VALUATED EXERCISETime:~OFMAZORPARAMETERS ENGINEERED SAFEGUARDS A.RUNNINGUNLOADEDTBOOSB.RUNNINGUNLOADEDTBOOSTSCRUNNINGUNLOADEDTBOOSSecurityRUNNINGUNLOADEDENGINEERED SAFEGUARDS OOSReactorShutdownYES0N-31~CPSN-32CPSN-35EAMPSN-36AMPSAvg.NuclearPowerRCSPressureaaCr8PSIGPRZRLevel~9(e.ARCPNSTOPPEDBRCPUNNINSTOPPED1AS/GLevel~.I1BS/GLevel~./1AS/GPressurePSZG1BS/GPressure7/trPSIGTurbine/Generator NLINOFFLINE4KVBusesNERGIDEENERGIZED 480VBusesNERGZEDEENERGZZED DCBatteries AISoVOLTSBI8aVOLTSCnmtPressure~lPSIGCnmtSumpALevel~9FEETCnmtSumpBLevelINCHESALoop'HotLegZK2~oFALoopColdLegKf'VIOFBLoopHotLeg.MOFBLoopColdLegOFRVLIS*CETtOo.7DFS/GATotalAuxFWFlowOGPMS/GBTotalAuxFWFlowC7GPMDIESELGENERATORS HihHeadS.Z.PumsFZ-924GPMFI-925OGPM1A.INSERVTBOOS1B.INSERVTBOOS1C.INSERVTBOOSBASTLevel=LowHeadS.I.PumsFI-6260GM1A.INSERVTOOSRECIRC1B.ZNSERVSTBOOSRECIRCRWSTLevel=1.h4Containment SraPumsFI-931AGPMFI-931BE3GPM1A.INSERVTOOS1B.INSERVTBOOSNaOHTankLevel=Containme tRecircFans1A.SESTBYOOS1B.SERSTBYOOS1C.INSERVTBOOS1D.NSERSTBYOOSPostAccidentDampersOPENServicetePums1A.ISESTBYOOS1B.NSESTBYOOS1CNSERSTBOOS1D.INSERVTBOOSA&BHeaderPressure78PSIGComonentCinWaterPums1A.NSESBYOOS1B.ZNSERVSTBOOSSurgeTankLevel=~204.SEAux.Feedwater ms1A.INSERVOOS1B.INSERVTOOSTurb.DrivenINSERVTBOOSCSTLevel2.FEET*CET=AverageofSelectedCoreStandbAux.FeeaterPums1CINSERVBOOS1D.INSERVTBOOSExitThermocouples Gs199208!45R.E.GIMQSit(ULATOR TRENDGIIPASIGN)(E)IT SUt(tIARY PA6E1GROUP:EVENT1PRXEDURE:

EPIP1-5PLA)ITSTATUSPOINTIDDESCRIPTION E.U.12356789101112131415161718202122232425262728293031323334353637383940414243444546474849505152ATMSRXTN31N32N35N36NPPRCSLPIRFRCLAFRCLBRXT16RXT17TSUBTCLSGALS68PSGAPSBBGENBKRlGENBKR2BUSiiABUS11BBUS12ABUS128B11A12A811B12BPCVLSIIPAL0942EL0943EL09429L0943DL0942CL0943CL09428L0943BL0942AL0943AT0409AT0410AT0450T0451TAVBAWIDTAViiBMID LRVTCCOREFAUXFWAFAUXFMBBKR081BKR082V3505V3504ANTICIPATED TRANSIENT M/0SCfUNREACTORTRIPBREAKERSTATUSSMKERANGEDETECTORN-31SINCERANGEDETKTORN-32INTEf(t(EDIATE RANGEDETECTORN-35INTEftt(EDIATE RANGEDETECTORN-36AVERAGENUCLEARPOWERREACTORCOOLANTSYSTEI(AVGPRESSPRESSURIZERAVERAGELEVELREACTORCOOLANTLOOPAAVGFLOWREACTORCGOLNTLOOPBAVGFLOWRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCORETCSUBCOOLED t(ARGINSTI(GENANARROWRANGEAVGLEVELSTMGENBt(ARROWRANGEAVGLEVELSTHBE)IAAVERAGEPRESSURESTtlGEN8AVERAGEPRESSUREGBGQTORONLINEBREAKER161372696QTORONLINEBREAKER9X1372BUS11ASUPPLYBREAKERBUS11BSL'PPLYBREAKERNOTTERMINATED ONPPCS(7/19/91)

NOTTERMINATED OMPPCS(7/19/91)

BUSllATo12ATIEBRENERBUS11BTo128TIEBREAKERCONTAIN)(ENT AVERAGEPRESSURECONTAItl<IEI(T SUt(PAAVERAGELEVELSU)PBLEVEL8I)ICHES(TRAINA)SUIP8LEVEL8INCHES(TRAIN9)SU)PBLEVEL78INCHES(TRAINA)SUIPBLEVEL78INCHES(TRAINB)SUtP8LEVEL113INCHES(TRAIN A)SU)P8LEVEL113INCHES(TRAIN 8)SUtPBLEVEL180INCHES(TRAIN A)SUtPBLEVEL180INCHES(TRAIN B)SPiP8LEVEL214INCHES(TRAIN A)9PPBLE4l3.214INCHES(TRAIN 8)RCLAHOTLEGTE)(PERATUR=

RCLBHOTLEGTE)IPERATURE RCLACOLDLEGTE)FERATNE RCLBCOLDLEGTEIIPERATNE RCLATAVB(THOT/TCOLD WIDERt(B)RCLBTAVG(THQT/TCOLD WIDERNG)REACTORVESSELAVERAGELEVELEl.1INCORETCAVERAGETEt(PS/6ATOTALAUXFEEDMATER FLOWS/GBTOTALAUXFEEDMATER FLOWt(TRAUXILIARY FEEINATER PU)IPAHTRAUXILIARY FEEDMATER PU)IPBAUXFMPUI(PSTEANSUPPLYVALVEAAUXFWPlNPSTEA)ISL'PPLYVALVEBNOATMSNOTTRIP1.00008001.0$N&006.3386AM5.88842M89.142263.46.598.497.3NOTTRIPNOTTRIP50.152.152.1717.716.NOTTRIPNOTTRIPNOTTRIPNOTTRIPNOTTRIPNOTTRIPTRIPPEDTRIPPED.111~9LONERLONER.LONERLOMERLOMERLOMERLONERLONERLOMERLONER597.2597.2544.1545.4570.6571.399.3600.7OFFOFFCLOSEDCLOSED6009GOODINHBINHDINHBINHD6009600DGoon6009600960096009Boos6009GOOD6009GOODGOOD6009600DBoonDELDELGOOD6009GOOD6009Goon60096009600960096009600960096009Goon600960096009600960096009600~GoonGOODGOOD6009.GOOD6009CPS0%fM(PAl(PXPSIGXXX"DEBFX/PSIGPSIGDEBFDEBFDEGFDEBFDEGFDE6FDEGFGPtfGPtl OCT8~199208:45R.E.GINASIMULATOR TREND6ROUPASSISNNENT SNINSYPA6E26RGUP:EVENT1PRXEDURE:

EPIP1-5PLANTSTARSPOINTIDDESCRIPTION VALUENALE.U.53FSIA54FSIB55P216056P216157BKR04158IMR04259IIR04360IIR044SAFETYINJECTION LOOPAAV6FLOWSAFETYINJECTION LOOPBAVGFLNSERVICE@TERPNtPSAhBHEADERSERVICENATERPLIPSChDHEADERSERVICENATERPNPASERVICENATERPIIP8SERVICEWATERPNrPCSERVICENATERmPn0.600D6PN0.600DGPN82.600DPSI673.6mPS16600D600D600D6009EMJ

~~~OGRAMNAME:LRGTSZ.E

.E.GINNANUCLEARPONERPLAHTOCT08,9208:45:00TRENDGROUPASSIGNMEHT SUMMARYGROUPNAMEEVENT2GROUPDESCRIPTION PROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURRENTVALUEDUALITYCODEENGRUNITS123456789101112131420212224252627282930313233343536373839404142430JF0619LRNSTWS033l$033MT033MT250NDT2R01R02R05R09R34R35R10AR11R12R108R13R14R18R'l9R29R30R15R12A5R12A6R12A7R12A9R14A5R14A7R14A9R15A5R15A7R15A9R31R32CVH'CV03,TCV07TCVOBTCV09TCV10TCV17COMPONENT COOLINGLOOPTOTALFLllREFUELING llATERSTORAGETANKLVL33FOOTLEVEL1JINOSPEED33FOOTLEVELLIINDDIRECTION 33FOOTLEVELTEHPERATURE 250FOOTLEVELTEHPERATURE 250TO33FOOTLEVELDELTATEHPAREA1-CONTROL ROOHAREA2-CONTAINHENT AREA5-SPEHTFUELPITAREA9-LETDONN LINEMONITORAREA34-AUXBLDGCVSPRAYPUHPAREA35-PASSSAMPLEPANELCONTAINHEHT IODINEMONITORR10ACONTAINMENT AIRPARTICULATE CONTAINMENT GASMOHITORPLANTVENTIODINEMONITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIQUIDllASTEDISPOSALMONITORSTEAMGENERATOR BLOlSONNDRAINAREA29-CONTAINMENT HIGHRANGEAREA30-COHTAINMENT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LINRANGEGASCVVENTCHAN6-AREAGAHMACVVENTCHAN7-MIDRANGEGASCVVENTCHAN9-HIGHRANGEGASPLAHTVENTCHAN5-LQIRAHGEGASPLANTVENTCHAN7-MIDRANGEGASPLANTVENTCHAN9HIGHRANGEGASAIREJECTORCHAN5-LOFTIRANGEGAS.AIREJECTORCHAN7-HIDRANGEGASAIREJECTORCHAN9-HlRANGEGASAREA31STEAMLINEA(SPING)AREA32STEAMLINE8(SPING)CVHYDROGEHCONCENTRATION CVBASEMENTLVL6FTTEMP¹3CVINTERMEDIATE LVL6FTTEMP¹7CVINTERMEDIATE LVL6FTTEMP¹8CVINTERMEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEHP¹10CVOPERATING LVL6FTTEMP¹171485.94.53.879.59.859.0-0.89.02214.02 6.40678+00 1.39946+00 3.40701+01 9.09354-01 1.09283+00 9.58719+01 5.18901+02 7.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658+03 4.07174+03 5.05861-01 5.09440.01 1.25835+05 1.89699-07 2.53990-02 3.57435.05 1.41261-03 4.40312.07 6.86543-05 3.72621-03 6.29179.03 6.29392-03 6.29436.03 1.02040-02 1.01048-02

.095.1106.0106.6106.7106.2117.5GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOODGOODGOODGOODHALHHWRNGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGPMMPHDEG.DEGFDEGFDEGFMR/HKR/HMR/HMR/HMR/HMR/HCPHCPMCPMCPHCPHCPMCPHCPMR/HRR/HRCPMUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRMR/HRXDEGFDEGFDEGFDEGFDEGFDEGF Time:~ggMessage:17INNATATIN12EVALATEDEXERIEMESSAEFRMMMMf:Qt<<L<<IRimladPlnoniin:~Megage:"""THISISANEXERCISE"""

Thefollowing annunciator isreceived:

~A-17(MotorOffRCPCCWP)FORCONTRLLERUSEONLYController Notes:1)Whenoperators checktheControlBoard,informthemthatthe1ACCWPumphastrippedandthe1BCCWPumphasstartedautomatically

~anisdelivering requiredflow(i.e.,TherearenoControlBoardalarmsthatwouldindicatelossofCCWFlow).AnticiateResults:1)Operators shouldperformtheapplicable actionsofAR-A-17.2)Operators shouldperformtheapplicable actionsofAP-CCW.2.

3)Operators shouldrequest,thattheAuxiliary OperatorsenttotheAuxiliary BuildingtoidentifytheCCWleak,isolatethe1ACCWPumpandrackoutitselectrical breaker.4)Operators shouldinformthepeoplemanningtheTSCofthe1ACCWPumpproblems.

Time:Jg'jQMessage:~1~INNATATIN192EVALATEDEXERIE~MEEAEFR~MI:IACCWPPMRIIEIFIIREITSimulaedPlanCondiions;SeetheAttachedMini-Scenario

~Mss~a"""THISISANEXERCISE"""

FORCONTROLLER USEONLYController Notes:1)Provideinformation verballywhenappropriate investigations aremade.AnticiatedResults:2)AsperMini-Scenario Anticipated Results.

NIINNIITATIN2EVALATEDEXERIE~MINI-NNAIIISCENARIO:

Failureofinboardmechanical sealonthe1AComponent CoolingWaterPump.INITIALCONDITIONS:

PlantOperating at97%powerwith1AComponent CoolingWaterPumpsupplying thesystem.CONDITIONS:

Theoperatorontourfindswatersprayingfromtheinboardsealof1AComponent CooingWaterPump,directlyonthe1Amotor.Caution;watercontainspotassium chromatewhichistoxic.ACTIONSREQUIRED:

1BCCWPumpSealleakingasmallamount.1AComponent CoolingWaterPumpsecured.PumpisolatedbyA-1401.Procedures andpackageforcorrective maintenance beprepared.

SparepartscheckedSWPrequestpreparedMaintenance shoprequested tocleanupspillwithaidofchemistry tech.OpenFlamepermitandFireWatchobtainedPumpuncoupled frommotorandcouplingremoved.Sealwaterpipingremoved.Mechanical sealremoved.Inboardbearingremoved.Shaftandstuffingboxinspected fordamageaftercleaning.

Newmechanical sealinstalled.

Bearinginspected andreplacedasnecessary.

Couplinginstalled andalignment accomplished.

Pumpreturnedtoservice.EXPECTEDRESULTS:1AComponent CoolingWaterPumpreturnedtoservice.ineighthoursafterrepairsstartedonunit.

Time:~5QMessage:~1INNATATIN12EVALATEDEXERE~MESAEFRM~f:IACCWPpMPPlIPpSIFIIRplTSimulaePlanConditions:

SeetheAttachedMini-Scenario

~Messae:"""THISISANEXERCISE"""

FORCONTROLLER USEONLY~CIIE1)Provideinformation verballywhenappropriate investigations aremade.AniciaedResuls:1)AsperMini-Scenario Anticipated Results.

gllNNil74TlN12EVALATEDEXERIE~MINI-CENARITITLE:1AWPmMorPrblmfromPmPkinFilrExpectedscenariostarttime:0850INITIALCONDITIONS:

Pumprunning.METHODOFINITIATION:

Breakertrips,Operations callsforElectricians toinvestigate.

INDICATIONS:

CONTROLROOM:~Alarmwindow:"A-17"MOTOROFF:RCP/CCWP~White(disagreement) light:CCP1ABUS14/POS23A:~Amptector:

"Instantaneous" TripIndication CCWP1AMOTOR:~Smellofburntinsulation

~WatersprayonmotorcaseEXPECTEDSEQUENCEOFACTIONS:oInvestigate Auxiliary Buildingforvisiblesignsnearbreakerormotor.~Noticesmellatmotor~NoticeCircuitBreakerAmptector targetfor"instantaneous" oObtainholds,clearances, andtestequipment.

oSimulatemeasuring resistance phasetophase5meggermotorfromBus14/Pos23Areadings:

Meggerreadings:

OMQtogroundPhasetophaseresistance:

(1Q0Simulatedetermofmotorandrepeatteststolocatefaultinmotorwindings.

oSuggestreplacing pumpandmotorwithspareunits.FINALCONDITIONS:

Motorrequiresreplacement duetoshortedwindings.

Windingsshortedduetowatersprayuponfailureofpumpseal.

Time:~~Message:~Q~INNATATIN12EVALATEDEXEREMESAEFRlVl~MI:NI<<C<<IRIINCRRITimulaePlanConiion:~Nlessae:"""THISISANEXERCISE"""

TheADFCSproblemwiththeMFWRegulating Valvesisrepaired.

FORCONTROLLER USEONLYC~lN1)TheIRCRepairTeamworkingontheADFCSshouldreportthismessagetotheSimulator ControlRoom.SimulaorConrolRoomConrollerandISCReairTeamController tocoordinaehisreora0855hours.AnticiatedResuls:1)Operators continueshuttingthePlantdownper0-2.1.

Time:3)~Message:21lNNATATION12EVALATEDEXEIEIVIEAEFRMMMMf:8ICIRSimulaedPlanCondiions:SeetheAttachedSheets~Messse:FORCONTROLLER USEONLYAnticiatedResults:1)Operators continueshuttingthePlantdownper0-2.1.

199Z'VALUATED EXERCISETime:d'FdbMAZORPARAMETERS ENGINEERED SAFEGUARDS HihHeadS.Z.PumsFI-924GPMFI-925~GP1A.INSERVTOOS1B.INSERVSBOOS1C.'NSERV OOSBASTLevel=LowHeadS.I.PumsFI-626OM1A.INSERVTOOSRECIRC1B.INSERVTBOOSRECIRCRWSTLevel=Containment SraPumsFI-931AOGPMFl-931B~GP 1A.ZNSERVTBYOOS1B~INSERVTOOSNaOHTankLevel=Containment ecircFans1A.NSESTBYOOS1B.SESTBYOOS1C.INSERVTOOS1D.SERSTBYOOSPostAccidentDampersOPENLOSEDServiceWatePums1A.STBYOOS1B.INSESTBYOOS1C.NSEVSTOOS1D.INSVTBOOSA&BHeaderPressureDIESELGENERATORS A.RUNNINGUNLOADEDBOOSB.RUNNINGUNLOADEDOOSTSCRUNNINGUNLOADEDTOOSSecurityRUNNINGUNLOADEDOOSPSIGComonentCoolinWatrPumsReactorShutdown~YESN-31CPSN-32CPSN-35AMPSN-36AMPSAvg.NuclearPowerRCSPressure&2.fe2PSZGPRZRLevel5r7ARCPINSTOPPEDBRCPINSTOPPED1AS/GLevel~a.I1BS/GLevel5at1AS/GPressurePSIG1BS/GPressure7s~PSIGTurbine/Generator ONLIOFFLINE4KVBusesNERGDEENERGIZED 480VBusesERDEENERGIZED DCBatteries A~goVOLTSBISOVOLTSCnmtPressure.ISPSIGCnmtSumpALevel~OFEETCnmtSumpBLevelINCHESALoopHotLegXm.-LoFALoopColdLeg899.IOFBLoopHotLeg~C.IOFBLoopColdLeg~,~iOFRVLIS*CET91lOFS/GATotalAuxFWFlowGPM5/GBTotalAuxFWFlow0GPMENGINEERED SAFEGUARDS Aux.Feedwater Pums1A.INSERVTOOS1B.INSERVTBOOSTurb.DrivenINSERVTBOOSCSTLevel~FEET*CET=AverageofSelectedCoreExit1A.STBY1B.NSERSTBYOOSSurgeTankLevel=StandbAux.FewaterPums1C.INSERVOOS1D.INSERVSTBOOSThermocouples 8>199209:00R.E.GINASIWLATORTRENDGROUPASSIGNNENT SUNNARYPAGE1GROUP:EVENT1PROCEDURE!

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION E.U.1235678r910111213141516f71819202122232425262728293031323335363738394041424344454647484951ATMSRXTN31N32N35N36NPPRCSLPIRFRMFR(uRXT16RXT17TSUBTCLSGALSBBPSGAPSGBGENBKR1BENBKR2BUSffABUS11BBUS12ABUS12BB11A12AB11B12BPCVLSUNPAL0942EL0943ELO'942DL0943DL0942CL0943CL0942B,L0943BL0942AL0943AT0409AT0410AT0450T0451TAVGAMIDTAVGBMIDLRV7CCOREFAUXFWAFAUXFMBBKR081BKR082V3505V3504ANTICIPATED TRANSIEhT M/0SCRANREACTORTRIPBREAKERSTATUSSMCERANGEDETECTORN-31SMKERANGEDETECTORN-32INIERNEDIATE RANGEDETECTORN-35INTERNEDIATE RANGEDETECTORN-36AVERAGENIKLEARPOWERREACTORCOOLANTSYSTENAVGPRESSPRESSURIIERAVERAGELEVELRECTORCOOLANTLOOPAAV6FLINREACTORCOOLNTLOOPBAVGFLOWRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCORETCSUBCOOLED NAPKINSTNGEt(ANARROWRANGEAVGLEVELSTNGENBNARROWRANGEAVGLEVELSTNBEt(AAVERAGEPRESSURESTN6ENBAVERAGEPRESSUREGENERATOR ONLINEBREAKER161372GBERATORONLINEBREAKER9X1372BUS11ASlFPLYBREAKERBUS11BSUPPLYBREAKERNOTTERNINATED ONPPCS(7/19/91) t(OTTERNINATED ONPPCS(7/19/91)

BUS11ATof2ATIEBREA'(ERBUS11BTO12BTIEBRENERCONTAINHENT AVENGEPRESSURECONTAINNENT RJNPAAVERAGELEVELSUtPBLEAL'8It(CHES(TRAINA)SU)PBLBtEL8It/CHES(TRAIN8)SUtPBLEVEL78INCHES(TRAINA)SUtPBLEVEL78INCHES(TRAINB)SU)PBLEVEL113INCHES(TRAIN A)SUtPBLEVEL113INCHES(TRAIN B)SU)PBLBr'EL180INCHES(TRAIN A)SUtPBLEVEL180INCHES(TRAIN B)SUlPBLEVEL214INCHES(TRAIN A)SUtPBLEVEL214INCHES(TRAIN B)RCLAHOTLEGTENPERATUiK RCLBHOTLE6TBPERATSK RCLACOLDLEGTE)IPERATlBE RCLBCOLDLEGTENPERATNE RCLATAVG(THOT/TCOLD WIDERNG)RCLBTAVG(THOT/TCOLD WIDERNG)REACTORVESSELAVERAGELEVELEl.lINCORETCAVERAGETENPS/6ATOTAjAUXFEECAIATER FLOWS/GBTOTALAUXFEEDMAWDFLOWNTRAUXILIARY FEEDMATER PUNPANTRAUXILIARY FEEDMATER PUNP9AUXFWPUNPSTEA)ISUPPLYVALVEAAUXFMPINPSTEAJISUPPLYVALVE8OFFOFFCLOSEDCLOSEDgr75NoATMSGOODNOTTRIPGOOD1.000008M INHH1.00000+00 INHB6.19439MINHB5,727~INHB86.94GOOD2262.600945.7600998.4600997.36009NOTTRIP6009NOTTRIP600951.8600~52.1GOOD52.16009723.6009722.BOOBNOTTRIP6009NOTTRirSOOnNOTTRIP6009NOTTRIP6009NOTTRIPDELNOTTRIPDELTRIPPED6009TRIPPED6009.1360092.06009LOWER6009LOWER6009LOWER6009LOWER6009LOWER6009LONER6009LONER6009LOWER6009LOWER6009LOWER6009596.16009596.16009544.16009545.2G009570.16009570.6600999.46009599.1600~0.60090.6009600969096009GOODCPSCPSANPANPXPSIBXXDEBFXXPSIGPSI6PSI6FEETDE6FDEGFDE6FDEBFKBFDEBFXKBFPNGPN OCT8~199209:00R.E.GIMjfASIffULATOR TRENDGfOUPASSIGNffENT SNIARYPA6E26ROUP'VENTI PfNlEDURE'PIP 1-5PLANTSTATUSPOINTIDDESCRIPTION VALUE.QUALE,',53FSIA54FSIB5SP216056P2I6157BffR04i58BffR04259BffR04360BKR044SAFETYINJECTION.

LOOPAAVGFLOWSAFETYINJECTION LOOPBAVGFLOWSERVICEWATERPNfPSAhBHEADERSERVICEWATERPNFSC50HEADERSERVICEWATERPNfPASERVICEWATERPUNP8SERVICEWATERPNfPCSEfIICEWATERPNfPD0.0.82.73,ONONONOFF600DPN600DGPN600DPSIGGOODPSIGGOOD600DGOODGOODEMJ

~l~IOGRAMNAME:LRGTSZ.E.E.GIHNANUCLEARPONERPLANTOCT08,9209:00:00TRENDGROUPASSIGNMENT SUHHARYGROUPHAMEEVENT2GROUPDESCRIPTIONPROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURREHTVALUEQUALITYCODEENGRUNITS1234567891011121314202'1222324252627282930313233343536373839404142430-F0619LRNSTIIS033l$033IIT033NT250M)T2R01R02R05R09R34R35R10AR11R12R10BR13R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14A5R14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03TCV07TCV08TCV09TCV10TCV17COMPONENT COOLINGLOOPTOTALFLUREFUELING llATERSTORAGETANKLVL33FOOTLEVELllINDSPEED33FOOTLEVELIIINDDIRECTIOH 33FOOTLEVELTEHPERATURE 250FOOTLEVELTEMPERATURE 250TO33FOOTLEVELDELTATEHPAREA1-CONTROL ROOHAREA2-CONTAINMEHT AREA5-SPEHTFUELPITAREA9-LETDONN LINEMONITORAREA34-AUXBLDGCVSPRAYPUHPAREA35-PASSSAHPLEPANELCONTAINMENT IODINEMONITORR10ACONTAIHHEHT AIRPARTICULATE CONTAINMENT GASHOHITORPLANTVENTIODINEHOHITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIQUID'HASTEDISPOSALMONITORSTEAMGENERATOR BLONDONHDRAINAREA29-CONTAINMEHT HIGHRANGEAREA30-CONTAINMEHT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LOURANGEGASCVVENTCKAH6-AREAGAMMACVVENTCHAN7-MIDRANGEGASCVVENTCHAN9-HIGHRAHGEGASPLANTVENTCHAN5-LOIRANGEGASPLANTVENTCHAM7-MIDRANGEGASPLANTVENTCHAN9-HIGHRANGEGASAIREJECTORCHAN5-LOURANGEGASAIREJECTORCHAN7-MIDRANGEGASAIREJECTORCHAN9-HIRANGEGASAREA31STEAMLINEA(SPIHG)AREA32STEAMLINEB(SPING)CVHYDROGENCONCEHTRATION CVBASEMEHTLVL6FTTEMP¹3CVINTERMEDIATE LVL6FTTEMP¹7CVINTERMEDIATE LVL6FTTEHP¹8CVINTERMEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEHP¹10CVOPERATING LVL6FTTEMP¹171485.94.53.152.59.959.3-0.69.02214-02 6.40678i00 1.39946+00 3.40701+01 9.09354-01 1.09283+00 9.5871&01 5.18901+02 7.38002+02 4.30543>01 8.58327+01 4.22831+01 2.78658t03 4.07174+03 5.05861-01 5.09440-01 1.25835+05 1.89699-07 2.53990-02 3.57435-05 1.41261-03 4.40312-07 6.86543-05 3.72621-03 6.29179.03 6.29392-03 6.29436.03 1.02040-02 1.01048-02

.095.1106.0106.6106.7106.2117.5GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOODGOODGOODGOODHALMHNRNGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGPMMPHDEG.DEGFDEGFDEGFMR/HMR/HMR/HMR/HMR/HMR/HCPMCPMCPMCPMCPHCPHCPMCPHR/HRR/HRCPMUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCHR/HRMR/HRXDEGFDEGFDEGFDEGFDEGFDEGFg-77 Time:~)~Message:22~INNATATIN2EVLTEDEERIEMESAEFRIVI~MI:MIN<<IRIAIIINRA<<IIIRR1ACCWPumpirnulaedPlanConiion:~ll/lesse e:"""THISISANEXERCISE"""

Thesuctionanddischarge valvesareclosedandtheelectrical breakerisrackedoutforthe1ACCWPump.FORCONTROLLER USEONLYController Notes:rrnrllrcordinaehisrora0905hors.1)TheAuxiliary Operatorisolating the1ACCWPumpshouldreportthismessagetotheSimulator ControlRoom.SimlarCnrIRmnrollrnAxiiirAnticiaedResuls:1)Operators shouldensurethatthe1ACCWPumpControlSwitchisinpullstop.2)Operators shouldensuretheCCWSurgeTankLevelhasreturnedtonormal(i.e.,~50%level).3)Operators continueshuttingthePlantdownper0-2.1.

Time:~~1Message:~3NIINNATATIN12EVALATEDEXERIE~MEAENRM~MI:NICIRSimulaedPlanCondiions:SeetheAttachedSheets~Meeeee:THISISANEXERCISEThefollowing annunciators arereceived:

~F-10(Pressurizer LoPress2185PSI)~F-4(Pressurizer LevelDeviation

-5Normal+5)~G-3(S/GALevelDeviation a7%)FORCONTROLLER USEONLY~CIIN1)Whenoperators checktheControlBoard,Informthemthat:~Pressurizer LevelandPressurearedecreasing uncontrollably.

~The"A"S/GWaterLevelisincreasing uncontrollably.

AnticiatedResults;1)Operators maymanuallyinitiateareactortripandstartperforming theimmediate actionsofE-0(ReactorTriporSafetyInjection).

2)Operators maymanuallyinitiateasafetyInjection andstartperforming theimmediate actionsofE-O, 199K'VALUATED EXERCISETime:MAZORPARAMETERS YES~@OCPSCPS0&AMPSXSEWAMPS2.(4PSIG~2.~INSTOPPEDSTPPEDPSIGPSIGOFFLINEDEENERGIZED DEENERGIZED B/SOVOLTS~I5PSIG~GFEET~~INCHES~3~90FOFGetoFoF~GPM~GPMReactorShutdownN-31N-32N-35N-36Avg.NuclearPowerRCSPressurePRZRLevelARCP'RCPRUN1AS/GLevel1BS/GLevel1AS/GPressure1BS/GPressureTurbine/Generator 4KVBusesNERGIZ480VBuseszDCBatteries A/BaVOLTS CnmtPressureCnmtSumpALevelCnmtSumpBLevelALoopHotLegALoopColdLegBLoopHotLegBLoopColdLegRVLIS*CETS/GATotalAuxFWFlowS/GBTotalAuxFWFlowDIESELGENERATORS A.RUNNINGUNLOADEDTBOOSB.RUNNINGUNLOADEDBOOSTSCRUNNINGUNLOADEDTBOOSSecurityRUNNINGUNLOADEDBOOSENGINEERED SAFEGUARDS ENGINEERED SAFEGUARDS HihHeadS.I.PumsFI-924GPMFI-925&GPM1A.INSERVBOOS1B.INSERVTBOOS1CINSERVTBOOSBASTLevel=LowHeadS.I.PumsFI-626OM1A.INSERVTOOSRECIRC1BINSERVTBOOSRECIRCRWSTLevel=Containment SraPumsFI-931AOGPMFZ-931B~GPM 1A.INSERVOOS1B.INSERVSTBOOSNaOHTankLevel=Containme ecircFans1A.ESTBYOOS1B.STBYOOS1C.INRVTBOOS1D.SERVSTBYOOSPostAccientDampersOPENLOSEDServicetPums1A.ESTBYOOS1B.SESTBYOOS1C.NSESTBOOS1'INSERVTBOOSA&BHeaderPressureggf3PSIGComonentCoolinWaterPums1A.INSESTBY1B.NSERVSTBYOOSSurgeTanvel=Aux.Feedwater Pums1A.INSERVTBOOSStandbAux.Feedwater Pums1B.INSERVTBOOS1C.INSERVTOOSTurb.DrivenNSERVTBOOS1D.INSERVSTBOOSCSTLevelMFE*CET=AverageofSelectedCoreExitThermocouples 8i199209:15R.E.GINASIMULATOR TREND6ROUPASSIBNMEHT SUMMARYPA6E1GROUP!EVENT1PRXEDURE:

EPIP1"5PLANTSTATUSPOINTIDDESCRIPTION E.U.1235678910li1213141516171819202122232425262728293031323334353637383940414243444546474849505152ATI6RXTN31N32N35N36NPPRCSLPIRRKLAFRCLBRXT16R)(T17TSUBTCLSGALSGBPSGAPS6BGENBKRlGENBKR2BUS11ABUS11BBUS12ABUS129BllA12AB11B12BPCVLSBPALO942EL0943ELO9420LO943DLO942CLO943CLO942BLO943BLO942ALO943ATO409ATO41OAT0450TO451TAVGAWIDTAVGBWfDLRVTCCOREFAUXFWAFAUXFWBBKRO81BKRO82V3SOSV3504ANTICIPATED TRANSIENT W/0SCRAMREACTORTRIPBREAKERSTATUSSMKERANGEDETKTORN-31SIKERANGEDETECTORN-32INTERtIEDIATE RANGEDETECTORN-35INTERMEDIATE RANGEDETECTORN-36AVERAGENUCLEARPOWERREACTORCOOLANTSYSTEMAVGPRESSPRESSURIIERAVERAGELEVELRECTORCOOLANTLOOPAAVGFLOMREACTORCOOLANTLOOPBAVGFLOWRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCORETCSUBCOOLED MARGINSTMGEt(ANARROWRANGEAVGLEVELSTM6ENBNARROWRANGEAVGLEVELSTMGRAAVERAGEPRESSURESTMGENBAVERAGEPRESSUREGEtERATOR ONLINEBREAKER1G13726BGQTORONLINEBREAKER9X1372BUS11ASUPPLYBREAKERBUS11BSUPPLYBREAKERNOTTERMINATED Ot(PPCS(7/19/91)

NOTTERMINATED OHPPCS(7/19/91)

BUS11ATo12ATIEBRENERBUS11BTO12BTIEBRENERCONTAINMEHT AVERAGEPRESURECOHTAINMEHT SUMPANERAGELEVELSUtpBLESS.8INCHES(TRAINA)SUtPBLEVEL8INCHES(TRAINB)SUtI'LEVEL78Ih(MS(TRAINA)SUtPBLESS78INCHES(TRAINB)SU%'LEVEL113INCHES(TRAIN A)SSP8LE4S.113INCHES(TRAIN B)SUtpBLEVEL180INCHES(TRAIN A)SUtPBLEVEL180INCHES(TRAIN B)SUtpBLE4S.214INCHES(TRAIN A)SUti'LE4S214INCHES(TRAIN B)RCLAHOTLEGTEMPERATURE RCLBHOTLEGTEMPERATURE RCLACOLDLEGTE)IPERATIRE RCLBCOLDLEGTE)IPERAT(SE RCLATNG(THOT/TCOLD WIDERNG)RCLBTAVG(THOT/TCOLD WIDERNG)REACTORVESSELAYERABELEVELEl.1IHCOFETCAVERAGETEPJ'/6ATOTN.AUXFEEDWATPFLOWS/6BTOTIAUXFEEC4ATRFLOWMTRAUXILIARY FEEDWATER PlIPAMTRAUXILIARY FEEDWATER PU)IPBAUXFWPUMPSTEA)ISUPPLYVN.VEAAUXFMPU)(PSTEAtlSUPPLYVALVEBNOATWSNOTTRIPi.OOOO(BOO1.0005800 5.99789M5.54624M84'32160.32.398.297.3NOTTRIPNorTRIP47.558.4'2.5726.724.NOTTRIPNOTTRIPNOTTRIPNOTTRIPNOTTRIPNOTTRIPTRIPPEDTRIPPED.132.0LONERLOWERLOWERLONERLONERLONERLONERLOWERLONERLONER593.7593.7543;1568.4569.199.3596.8O.O.OFFOFFCLOSEDCLOSED6000GOODINHBINHDINHHINHD600DGOODGOODGOOD6000GOODGOM600~HNRHGOODGOOD600D6000600060006000DELDEL6000600060006009600060006000GOOD60006000GOOD60006000GOOD6000GOODeOODGOOD6000GOODGOODGooeGOOD60006000GOOD60006000CPSCPSQ(PAMP/PSI6XXDE6FXPSIGPSI6DEGFDE6FDEGFDEGFDEGFDEBFXDEGFPM6PM XT8~199209:15R.E.GINASIMULATOR TRENDGROUPASSIGNMENT SUMMARYPAGE2POINTIDDESCRIPTION VALUEQUALE.'U.GRIP;EVENT1PROCEDURE:

EPIP1-5PLANTSTATUS53FSIA54FSIB55P216056P216157BKR04158BKR04259BKR04360BKR044SAFETYINJECTION LOOPAAVGFLOWSAFETYINJECTION LOOPBAVGFLNSERVICENTERPINPSAhBHEADERSERVICENATERPlIPSChDHEADERSERVICEWATERPIIPASERVICEWATERP1IPBSERVICENATERPNfPCSERVICEWATERPlIPD0.600D0.GOOD82.600D73.GOOD600D6009GOODGOOnGPMGPMPSIGPSIG

~~~OGRAMNAME:LRGTSZ.E

.E.GINNANUCLEARPONERPLANTOCT08,9209:15:00TRENDGROUPASSIGNMEHT SUMHARYGROUPNAMEEVENT2GROUPDESCRIPTION PROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTIONCURRENTVALUEQUALITYCODEENGRUNITS12345678910111213142021222425262728293031323334353637383940414243-F0619LR'NSTIIS033ND033MT033'NT250NDT2R01R02R05R09R34R35R10AR11R12R10BR13R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14A5R14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03TCV07TCVOBTCV09TCV10TCV17COMPOHENT COOLINGLOOPTOTALFLllREFUELING MATERSTORAGETANKLVL33FOOTLEVELHINDSPEED33FOOTLEVELMINDDIRECTION 33FOOTLEVELTEMPERATURE 250FOOTLEVELTEMPERATURE 250TO33FOOTLEVELDELTATEHPAREA1-CONTROL ROOMAREA2-CONTAINMENT AREA5-SPENTFUELPITAREA9-LETDONN LINEMONITORAREA34-AUXBLDGCVSPRAYPUHPAREA35-PASSSAMPLEPANELCONTAINMENT IODINEMONITORR10ACONTAINMENT AIRPARTICULATE CONTAINMENT GASHOHITORPLANTVENTIODINEMOHITORR108AUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASHONITORLIQUIDHASTEDISPOSALHOHITORSTEAMGEHERATOR BLONDONNDRAIN~AREA29-CONTAINMENT HIGHRANGEAREA30-CONTAINHENT NIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LOURANGEGASCVVENTCHAN6-AREAGAMMACVVENTCHAN7-HIDRANGEGASCVVENTCHAN9-HIGHRAHGEGASPLANTVENTCHAN5-LOMRAHGEGASPLANTVENTCHAN7-MIDRANGEGASPLANTVENTCHAN9-HIGHRANGEGASAIREJECTORCHAN5-LSIRANGEGASAIREJECTORCHAH7.HIDRANGEGASAIREJECTORCHAH9-HlRANGEGASAREA31STEAMLINEA(SPING)AREA32STEAHLINE8(SPING)CVHYDROGENCONCENTRATIOH CVBASEMENTLVL6FTTEMP¹3CVINTERHEDIATE LVL6FTTEMP¹7CVINTERHEDIATE LVL6FTTEHP¹8CVINTERMEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEMP¹10CVOPERATING LVL6FTTEMP¹171485.94.53.850.60.760.70.09.02214.02 6.40678+00 1.3994&001~47701+029.09354-01 1.09283+00

'.58719+01 5.18901+02 7.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658+03 1.57174t04 5'5861-015.09440-01 9.99999+06 1.89699-07 2.53990-02 3.57435-05 1.41261-03 4.40312-07 6.86543-05 3.72621.03 9.99999.03 1.85392+00 1.85436+00 3.02040+00 1.01048-02

.095.1106.0106.6106.7106.2117.5G(XmGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODBALMGOODGOODHALMGOODGOODGOODGOODGOODHALHHALMHNRNNALHGOODGOODGOODGOODGOODGOODGOODGOODGPMXMPHDEG.DEGFDEGFDEGFMR/HMR/HHR/HMR/HHR/HHR/HCPHCPHCPMCPMCPMCPHCPMCPHR/HRR/HRCPHUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCHR/HRMR/HRDEGF.DEGFDEGFOEGFDEGFDEGF Time:~9~7Message:24INNATATIN2EVALATEDEXEEMEAGEFOM~MI:RIIRIRimIPlnin:SeetheAttachedSheets~Mesea"""THISISANEXERCISE"""

Thefollowing annunciators arereceived:

~D-20(Pressurizer LoPressTrip1873PSI)~D-19(Pressurizer LoPressSl1750PSIG)FRCONTROLLER USEONLYController Notes:1)Allsafeguards equipment

required, operates, AnticiaedResIs:1)Operators shouldperformtheimmediate actionsandsubsequent actionsofE-0(ReactorTriporSafetyInjection).

2)AnALERTshouldbedeclaredinaccordance withEPIP1-0,"GinnaStationEventEvaluation andClassification,"

EAL:SteamGenerator TubeRupturelSGTR);SGTR>100gpm.3)Operators shouldalsobeperforming theapplicable actionsofthefollowing procedures:

a)EPIP1-2(ALERT)b)EPIP1-5(Notifications) c)0-9.3(NRCImmediate Notification).

199Z'EVALUATED EXERCISETIme:G'IllMAZORPARAMETERS ENGINEERED SAFEGUARDS ReactorShutdownESNON-31~CPSN-32CPSN-35eAMPSN-36-tAMPSAvg.NuclearPowereRCSPressureI7PSIGPRZRLevel0ARCPSTOPPEDBRCPUNNISTOPPED1AS/GLevel~lO.1BS/GLevel~l1AS/GPressure~(SPSIG1BS/GPressuret3PSIGTurbine/Generator OFFLINE4KVBusesNERGIZEDEENERGIZED 480VBusesNRGIZEDEENERGIZED DCBatteries A~TOVOLSBlSOVOLTS CnmtPressure~(PSZGCnmtSumpALevelFEETCnmtSumpBLevelINCHESALoopHotLeg~~eOFALoopColdLeg~G~ZOFBLoopHotLegOFBLoopColdLeg~5OFRVLZS*CET~~.SOF.S/GATotalAuxFWFlowGPMS/GBTotalAuxFWFlowGPMDIESELGENERATORS A.NINGUNLOADESTBYOOSB.UNNINGUNDESTBOOSTSCRUNNEDTBOOSSecurityRUNNINGUNLOADDTBOOSENGINEERED SAFEGUARDS Aux.FeedwterPums1A.SESTBYOOS1B.NERSTBYSTurb.DrivenSERSTBYOOSCSTLevelg~~hFEET*CET=AverageofSelectedCoreExitHihHeadS.I.PumsFI-9240.GPMFZ-9250GPM1ASESTBYOOS1BSTBYOOS1C.INSERVSTBYOOSBASTLeve=~7LowHeadS.Z.PumsFI-62GPM1A.SERSTBYOOSRECIRC1B.SERVSTBYOOSRECIRCRWSTLevel=V.Containment SraPumsFZ-931AOGPMFI-931BOGP1A.INSERVST1B.INSERVNaOHTankLevel=OOSOOSServiceWtePums1A.SESTBYOOS1B.SESTBYOOS1C.STBYOOS1D.INSERSTBYOOSA&BHeaerressurePSIGComonentCoolinWaterPums1A.INSTBY01B.NSERVSTBYOOSSurgeTanLevel=Containment RecircFans1A.NSSTBYOOS1B.INSESTBYOOS1C.STBYOOS1D.INSESTBYOOSPostAcctentDampersOPENCLOSEDStandbAux.FeaterPums1C.INSERVTOOS1D.ZNSERVTBOOSThermocouples 8)199209'17R.E.GINASitmLATOR

'REN9GROUPASSIGNMEt(T SUt(MARYPAGE16ROUP:EVEHT1PROCEDURES EPIP1-5PLANTSTATUS12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152POINTIDATWSRXTN31N32N35H36NPPRCSLPIRFRCLAFRCLBR)(T16RXT17TSUBTCLSGALSGBPSGAPSGBGENBKRlGENBKR2BUS11ABUS11BBUS12ABUS12BB11A12AB11B12BPCVLSUMPAL0942EL0943EL0942DL0943DL0942CL0943Cl.0942BL0943BL0942AL0943AT0409AT0410AT0450T0451TAVGAWIDTAVGBMIDLRVTCCOREFAUXFWAFAUXFWBBKR081BKR082V3505V3504DESCRIPTION ANTICIPATED TRANSIENT W/0SCRAMREACTORTRIPBREAKERSTATUSSmSCERANGEDETECTORN-31SRSCERANGEDETECTORH-32INTERMEDIATE RANGEDETECTORN-35IHTERt(EDIATE RAN6EDETECTORN-36AVERAGENUCLEARPOWERREACTORCOOLANTSYSTENAVGPRESSPRESSURIIER AVERAGELEVELREACTORCOOLNTLOOPAAVGFLOWREACTORCOOLANTLOOPBAVGFLOWRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCORETCSUKOOLEDMARINSTtlGENANARROWRANGEAVGLEVELSTMGB(BNARROWRANGEAVGLEVELST)(GENAAVERAGEPRESSURESTtlGENBAVERAGEPRESSUREGBERATORONLINEBREAKER161372GE%MTORONLINEBREAKER9X1372BUS11ASUPPLYBREAKERBUS11BSUPPLYBREAKERNOTTERMINATED ONPPCS(7/19/91)

NOTTERMINATED ONPPCS(7/19/91)

BUS11ATo12ATIEBRENERBUS11BTo129TIEBREAKERCONTAINMENT AVERAGEPRESSURECONTAIt(t~

SUt(PAAVERAGELEVELSU)PBLEVEL8INCHES(TRAINA)SUtPBLEVEL8INCHES(TRAIN9)SU)PBLEVEL78iNCHES(TRAINA)SUtPBLEVEL78INOZS(TRAINB)SUIPBLBtEL113INCHES(TRAIN A)SUIPBLEVEL113INCHES(TRAIN B)SUtPBLEVEL180INCHES(TRAIN A)SUtPBLEVEL180INCHES(TRAIN B)SUtPBLEVEL214INCHES(TRAIN A)SU)PBLEVEL214INCHES(TRAIN B)RCLAHOTLEGTBIPERATUK RCLBHOTLE6TBIPERATNK RCLACOLDLEGTE)IPERAT(RE RCLBCOLDLEGTE)IPERAT(SE RCLATAVG(THOT/TC(LD WIDERNG)RCLBTAVG(THOT/TCOLD WIDERNG)REACTORVESSELAVERAGELEVELEl.1It(CORETCAVERAGETBIPS/GATOTALA'JXFEEDWATER FLOWS/GBTOTALA)JXFEEDMATER FLOWt(TRAUXILIARY FEEDWATER PUMPAtITRAUXILIARY FEEDMATER PUMP9AUXFWPUMPSTEA)ISUPPLYVALVEAAUXFMPUMPSTEA)ISUPPLYVALVEBGUALOHONOPENOPENAIMSALRt(RXTRIPPEDALRII1.00000+(e INHB1.00000I00 INHS4.20726-06 60093.59748M6009.59600D1474.LAB.0LALI(98.9GOOD98.0600DNOTTRIP600DNOTTRIP600951.7600~10.8LALM7.1LALN913.6009913.6009NOTTRIP6009NOTTRIP6009NOTTRIP6009NOTTRIP6009NOTTRIPDELHOTTRIPDELTRIPPED6009TRIPPEDGOOD.11GOOD2.06009LOWER6009LOWER6009LONER6009LOWER6009LOWER6009LOWER6009LOWER6009LOWER6009LOWER6009LOWER6009543.66009543.66009536.26009537.36009539.96009540.2600099.56009539.3Goo'78.GOOD484.60096009GmALRtfALRtlE.U.CPSCPSAt(PAMPXPSIGX,XXKGFXXPSI6PSIGPSI6FKDE6FKGFDEGFDEGFDEGFDEGFXDFGFPNGPN

OCT&s199209'17R.E.GINASIWLATORTREND6ROUPASSI6NENT RNHARYPAGE2GROUP:EVENT1PRXEDURE:

EPIP1-5PLANTSTATUSPOINTID53FSIA54FSIB55P216056P216157BKR04158BKR04259BKR04360BKR044DESCRIPTION SAFiiYINJECTION LOOPAAVGFLOWSAFETYINJECTION l.OOPBAVGFLOWSERVICEWATERPIIPSA5BHEADERSERVICEWATERPNPSChDHEADERSERVICEWATERPlNPASERVICEWATERPUNPBSERVICEWATERPlmPCSERVICEWATERPUMPDONONONONVALUEOUALE.U.101.600D6Ptl101.GOODGPH85.GOODPSIG85.GOODPSI6600D600DGOODGOODEMJ

~~~QIOGRAMHAME:LRGTSZNE

.E.GINNANUCLEARPOMERPLANTOCT08,9209:17:00TRENDGROUPASSIGMHEHT SUHMARYGROUPNAMEEVENT2GROUPDESCRIPTIOHPROCEDURE:

EPIP1-5PLANTSTATUSPOINTIODESCRIPTION CURRENTVALUEQUALITYCODEENGRUNITS123567891011121314202122232425262728293031323334353637383940414243-F0619LRlISTMS033l$033MT033MT250MDT2R01R02R05R09R34R35R10AR11R12R108R13R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14A5R14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03TCV07TCVOBTCV09TCV10TCV17COMPONENT COOLINGLOOPTOTALFLlIREFUELING MATERSTORAGETANKLVL33FOOTLEVELIIINDSPEED33FOOTLEVELlIINDDIRECTION 33FOOTLEVELTEHPERATURE 250FOOTLEVELTEMPERATURE 250TO33FOOTLEVELDELTATEMPAREA1-CONTROL ROOMAREA2-COHTAINHENT AREAS.SPENTFUELPITAREA9.LETDOMN LINEMOHITORAREA34-AUXBLDGCVSPRAYPUHPAREA35-PASSSAMPLEPANELCOHTAINHENT IODINEMONITORR10ACONTAINMEHT AIRPARTICULATE CONTAINMEHT GASMONITORPLANTVENTIOOIHEMOHITORR108AUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXNAUSTGASMONITORLIQUIDMASTEDISPOSALMONITORSTEAMGENERATOR BLOleOllH DRAINAREA29-COHTAINMEMT HIGHRANGEAREA30-CONTAIHMENT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LNIRAHGEGASCVVENTCHAN6AREAGAMMACVVENTCHAM7-HIDRANGEGASCVVENTCHAN9-HIGHRAHGEGASPLANTVENTCHAN5-LNIRANGEGASPLANTVENTCHAN7-HIDRAHGEGASPLANTVENTCHAM9-HIGHRANGEGASAIREJECTORCHAH5-LOURANGEGASAIREJECTORCHAN7-MIDRAHGEGASAIREJECTORCHAN9-HlRANGEGASAREA31STEAMLINEA(SPIMG)AREA32STEAMLIHE8(SPING)CVHYDROGENCONCENTRATION CVBASEMEHTLVL6FTTEHP¹3CVINTERMEDIATE LVL6FTTEHP¹7CVINTERMEDIATE LVL6FTTEMP¹8CVINTERMEDIATE LVL6FTTEHP¹9CVINI'ERMEDIATE LVL6FTTEMP¹10CVOPERATING LVL6FTTEMP¹171485.94.53.850.60.760.70.09.02214.02 7.35678+00 1.3994&001.47701+02 9.09354-01 1.09283+00 9.58719+01 5.18901+02 7.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658+03 1.57174+04 5.05861.01 5.09440-01 9.~061.89699-07 2.53990-02 3.57435-05 1.41261-03 4.40312-07 6.86543-05 3.72621-03 9.99999.03 1.85392+00 1.85436+00 3.02040+00 1.01048-02

~095.1106.0106.6106.7106.2117.56(XO6000QXX)GOOD6000GOODGOODGOODGOOD6000GOODGOODGOODGOOD60006000GOODGOODGOODGOOD~HALMGOODGOODHALMGOODGOODGOODGOODGOODGOODGOODHALHHALMHMRHMALMGOODGOODGOODGOODGOODGOODGOODGOODGPHXMPHDEG.DEGFDEGFDEGFMR/HMR/HMR/HMR/HMR/HMR/HCPMCPMCPMCPMCPMCPMCPMCPMR/HRR/HRCPMUCI/CCHR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRMR/HRDEGFDEGFDEGFDEGFDEGFDEGF Time:~20Message:~2Sl~NASTATION2EVLTEDEXEREMEAEFRIVI~MN:SII<<NINSimulated PlanCondiions:SeetheAttachedSheets~Massae:"""THISISANEXERCISE"""

FORCONTROLLER USEONLY~NIINAnticiaedResults:1)Operators performing theapplicable actionsofE-O.2)Operators shouldbetransitioning toE-3(SteamGenerator TubeRupture).

199PEVALUATED EXERCISETime:092.OMAZORPAE&METERS ENGINEERED SAFEGUARDS HihHeadS.I.PumsFl-924I5GPMFI-925GPM1A.NSESTBYOOS1B.NSERSTBYOOS1C.INSERVSTBYOOSBASTLeveLowHeadS.I.PumsFI-626OGPM1A.NSESTBYOOSRECIRC1B.NSESTBYOOSRECIRCRWSTLevel=Containment SraPumsFI-931AOGPMFI-931B0GPM1A.INSERVBOOS1B.INSERVBOOSNaOHTankLevel=Containment RecircFans1A.NSERSTBYOOS1B.NSESTBYOOS1C.SERVSTBYOOS1D.NSEVSTBYOOSPostAcesentDampersOPECLOSEDServiceWaterPums1ASESTBYOOS1B.ESTBYOOS1C.SERSTBYOOS1D.NSERSTBYOOSA&BHeaderressureggP8PSIGComonentCoolinWaterPumsDIESELGENERATORS A.UNNINGUNLOADESTBYOOSB.RUNNINGUNLOADEDSTBYOOSTSCRUGLODEDSTBOOSSecurityRUNNINGUNLOADEDTBOOSReactorShutdownESNON-31~CPSN-32CPSN-35AMPSN-36Q+-AMPSAvg.NuclearPoweroRCSPressure~s&7PSIGPRZRLevelARCPUNNISTOPPEDBRCPUNNINGSTOPPED1AS/GLevelso.ta1BS/GLevel.11AS/GPressurePSIG1BS/GPressurePSIGTurbine/Generator FFLINE4KVBusesNERGIZDEENERGIZED 480VBusesNEDDEENERGIZED DCBatteries AI'SbVOSB~3oVOLTS CumtPressure~dPSIGCnmtSumpALevel.0FEETCnmtSumpBLevelINCHESALoopHotLeg'f043OFALoopColdLegM4LXoFBLoopHotLegOFBLoopColdLegOFRVLISf3*CETOaOFS/GATotalAuxFWFlowOGPMS/GBTotalAuxFWFlow~gGPMENGINEERED SAFEGUARDS 1A.INSERVSTBY1B.SERSTBYOOSSurgeTankLevel=~2-Aux.Feedwater Pums1A.SESTBYOOSStandbAux.Feedwater Pums1B.INSERVSTBYOOS1C.INSERVTBOOSTurb.DrivenINSERVTBOOS1D.INSERVTBOOSCSTLevel~fF*CET=AverageofSelectedCoreExitThermocouples 8-fo 8,199209:21R.E.GINASit(ULATOR TRENDGROUPASSIGN)(ENT SUl(NARYPAGE1GROUP!EVENTiPROCEDURE(

EPIP1-5POINTIDDESCRIPTION PLANTSTATUSE.U.1234578910111213141516171819202122232425262728293031323334353637383940414243444546474849505152ATMSRXTN31N32N35N36'NPPRCSLPLRFRMFRCLBRXT16RXT17TSUBTCLSSALSSBPSGAPSGBGENBKR1GENBKR2BUSIIABUS11BBUS12ABUS12B811A12AB11812BPCVLSI(PAL0942EL0943EL0942DL09439L0942CL0943CL0942BL0943BL0942At0943AT0409AT0410AT0450T0451TAVGAMIDTAVSBWIDLRVTCCOREFAUXFWAFAUXFWBBKR081BKR082V3505V3504ANTICIPATED TRANSIENT W/0SCRI(REACTORTRIPBREAKERSTATUSSMKERANGEDETECTORN-31SIIKERANGEDETECTORN-32.INTERt(EDIATE RANGEDETECTORN-35INTERt(EDIATE RANGEDHECTORN"36AVERAGENXLEARPOWERREACTORCOOLANTSYSTEt(AVGPRESSPRESSURIIER AVERAGELEVELREACTORCOOLANTLOOPAAVGFLOWREACTORCOOLNTLOOPBAV6FLNRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCQRETCSUBCOOLED t(ARSINSTt(GEt(ANARRNRANGEAVGLEVELSTt(BENBNARROWRANGEAVGLEVELSTt(SEt(AAVERAGEPRESS(EESTHGENBAVERAGEPRESSURE6BERATORONLltKBREAKER161372aaeuTORoNLINEBREAKER9ra372BUS11ASUPPLYBREAKERBUSiiBSUPPLYBREAKERNOTTERt(INATED Ot(PPCS(7/19/91)

NOTTERNINATED ONPPCS(7/19/91)

BUS11ATQ12ATIEBREWERBUS11BTQ12BTIEBREWERCONTAIttt(ENT AVERAGEPRESSURECONTAINt(ENT RIPAAVERAGELEVELSU)PBLEVEL8INCHES(TRAINA)SU)PBLEVEL8INCHES(TRAINB)SU)PBLEVEL78INCHES(TRAINA)SU)PBLEVEL78INCHES(TRAINB)SUtPBLEVEL113INCHES(TRAIN A)SU)PBLEVEL113INCHES(TRAIN B)SU)PBLEVEL180INCHES(TRAIN A)SUtPBLEVEL180INCHES(TRAIN B)SUtPBLEVEL214INCHES(TRAIN A)SUtPBLEVEL214INCHES(TRAIN B)RCLAHOTLEGTEt(PERATURE RCLBHOTLE6TEt(PERATURE RC(ACOLDLEGTEt(PERAT(SE RCLBCOLDLEGTEt(PERATlRE RCLATAVG(THOT/TCOLD WIDERNG)RCLBTAVG(THQT/TCOLD MIDERNG)REACTORVESSELAVERAGELEVELE1.1INCORETCAVERAGETEt(PS/6ATOTALAUXFEEDMATER FLNS/GBTOTALAUXFEEDWATER FLNt(TRAUXILIARY FEEDMATER PUt(PAHTRAUXILIARY FEEDWATER PUlPBAUXFMPUtPSTEA)lSUPPLYVALVEAAUXFMPUt(PSTENiSL%'PLYVALVEBATWSRXTRIPPED1.0000(MO1.00000+00 6.79204M5.80759M.021267..098.197.3NOTTRIPNOTTRIP35.030.828.7941.941-.TRiPPEDTRIPPEDTRIPPEDTRIPPEDNOTTRIPNOTTRIPNQTTRIPNOTTRIP.082.0LOWERLONERLONERLONERLNERl.OWERLNERLNERLNERLONER540.3540.3538.8538.4539.7539.499.3540.50.198.ONONCLOSEDCLOSEDALRt(ALRt(INHBINHB600960096009LALNLALN60096009GOOD6009600~GOODLWRt(60096009ALRt(ALRt(ALRt(ALRNDELDELALRt(ALRt(6009GOODsoonGOOD60096009Goon6009600960096009GOOD60096009600960096009SOQD6009Goo<6009GOOD6009GOOD60096009CPSCPSAt(PAt(Py.PSIG'l7lDEGFXy.PSIGPSIGDEGFDEBFDEGFDE6FDEGFDESFKDE6F6PN6Pt(

OCT8)1%2N:21R.E.GINASIILATORPAGE2TREND6ROUPASSIMENTSUNRY6ROUP:EVENT1PRXEOUREl EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION QUALE.U.53FSIA54FSIB55P216056P216157BKR04158IIR04259INR04360IIR044SAFETYINJECTION.

LOOPAAVGFLOWSAFETYINJECTION LOOPBAVGFLOWSERVICEWATERPNPSAhBHEADERSERVICEWATERPNFSChDHEADERSERVICEWATERPNFASERVICEWATERPlIPBSERVICEWATERPIIPCSERVICEWATERPNPD145.145.85.85.600DPNGOODGPNSOOnPSIG6009PSIGGOODGOODGOODGOODEMJ Time:~3gMessage:26INNATATIN2EVLATEDXEREMEAEFRM~llii:'ii<<L<<iRSimulaePlanniions:SeetheAttachedSheets~INessee:"""THISISANEXERCISE"""

FORCONTROLLER USEONLYController Notes:AnticiatedResults:1)Operators performing theApplicable ActionsofE-3.2)TheRupturedSteamGenerator shouldbeisolatedatapproximately thistime,ti.e.,secondary side).86 199K'VALUATED EXERCISETime:00'50ENGINEERED SAFEGUARDS HihHeadS.I.PumsMAJORPARAMETERS FI-924GPMFI-9252'j~GPM1A.SESTBYOOS1BSESTBYOOS1CNSERSTBYOOSBASTLave=~OLowHeadS.I.PumsFI-626OGM1A.INSERVTBOOSRECIRC1B.INSERVTBOOSRECIRCRWSTLevel=Containment SraPumsFI-931AQGPMFl-931BDGPM1A.INSERVTBOOS1B.INSERVTBOOSNaOHTankLevel=~4ContainmntecircFans1A.NSERVSTBYOOS1B.NERVSTBYOOS1C.SSTBYOOS1D.NSERSTBYOOSPostAccidentDampersOPECLOSEDServiceWaerPums1A.NSERVSTBYOOS1B.'SERSTBYOOS1C.SERSTBYOOS1D.NSERSTBYOOSA&BHeaderressure~APSIGComonentCoolinWaterPumsDIESELGENERATORS A.UNNINGUNLOADSTBYOOSB.EDSTBYOOSTSCDTBOOSSecurityRUNNINGUNLOADBOOSReactorShutdownESNON-31CPSN-32~CPSN-35!-IIAMPSN-36~~wlAMPSAvg.NuclearPoweroRCSPressurePSIGPRZRLevelARCPSTOPPEDBRCPUNNINSTOPPED1AS/GLevel1BS/GLevel~o&1AS/GPressure~5PSIG1BS/GPressure0PSIGTurbine/Generator NEFFLIN4KVBusesRGIZEDEENERGIZED 480V.BusesNERGIZDEENERGIZED DCBatteries A~5oVOLTSB/SbVOLTSCnmtPressure.oaPSIG-CnmtSumpALevel~3.FEETCnmtSumpBLevelINCHESALoopHotLeg~OFALoopColdLegZiOFBLoopHotLeg~OFBLoopColdLeg~4OFRVLISi+i~*CET~92,3OF'/GATotalAuxFWFlowOGPMS/GBTotalAuxFWFlow~IGGPM1A.INSERVSTBY001B.NSEVSTBYOOSSurgeTanvel=5~4ENGINEERED.

SAFEGUARDS Aux.Feedwater Pums1A.INSERVTBOOS1B.SERSTBYOOSTurb.DrivenINSERVBOOSCSTLevel/FEET*CET=AverageofSelectedCoreExitThermocouples StandbAux.FeeaterPums1C.INSERVTBOOS1D.INSERVTBOOS 8s199209!30R.E.GINASI)ILATOR PAGE1TRENDGROUPASSIGN%AT SUt(t(ARY DESCRIPTION GROUP'VENT1 PROCEDURE'PIP f<POINTIDPLANTSTATUSE.U.123456789f01112131415161718f92021222324252627282930313233343536373839404142434446474849505152ATiSRXTN31'32ta5N36NPPRCSLPLRFRCLAFRCLBRXT16RXT17TSUBTCLSGALSGBPSGAPS6BGENBKRfGENBKR2BUS11ABUS11BBUS12ABUS12B811A12AB11812BPCVLSI(PAL0942EL0943ELO'942DL0943DL0942CL0943CL09428L0943BL0942AL0943AT0409AT0410AT0450TO451TAVGAWIDTAVGBWIDLRVTCCOREFAUXFWAFAUXFWBBKR081BKR082V3505V3504ANTICIPATED TRANSIENT W/0SCRAt(REACTORTRIPBRENERSTATUSSMCERANGEDETECTORN-31SONCERI(GEDETECTORN-32INTER)(EDIATE RANGEDETECTORN-35INIEt(t(EDIATE RAN6EDETKTORN-36AVERA6ENUCLEARPOWERREACTORCOOLANTSYSTEt(AVGPRESSPRESSURIlERAVERAGELEVELREACTORCOOLNTLOOPAAVGFLOWREACTORCOOLANTLOOPBAVGFLOWRCPABRENERCAUSERXTRIPRCPBBRENERCAUSERXTRIPINCORETCSUBCOOLED t)ARGINSTtlGB(ANARROWRANGEAVGLEVELSTNGENBNARROWRANGEAVGLEVELSTttGENAAVERAGEPRESSURESTt(GEN8AVERA6EPRESSUREGBGQTORONLINEBRENER161372GamATORON~INEBREAKER9X1372BUSf1ASUPPLYBRENERBUS11BSLPPLYBRENERNOTTERNINATED OttPPCS(7/19/91)

NOTTERt(INATED OWPPCS(7/19/91)

BUS11ATO12ATIEBRENERBUS11BTO128TIEBRENERCONTAIN)(ENT AVERAGEPRESSURECONTAINEhT PJt(PAAVcCAGELE4l3.SUtP8LEVEL8INCHES(TRAINA)SUtP8LEVEL8INCHES(TRAINB)SUtP8LEVEL78INCHES(TRAINA)SUtP8LEVEL78INCHES(TRAIN8)SUtPBLEVEL113INCHES(TRAIN A)SSPBLEVEL113INCHES(TRAiN 8)SUtPBLEVEL180INES(TRAIN A)SUtPBLEVEL180INCHES(TRAIN B)SUtPBLEVEL214INCHES(TRAIN A)SUtfBLEVl3.214INCHES(TRAIN B)RCL4HOTLEGTB(PERATUK RCLBHOTLEGTB(PERATNK RCLACOLDLEGTB(PERAT(mE RCLBCOLDLE6TB(PERATIRE RCLATAVG(TNT/TCOLD WIDERN6)RCLBTAVG(THOT/TCOLD WIDERNG)REACTORVESSELAVERAGELEVELEi.fINCORETCAVERAGETB(PS/GATOTALAUXFEEDWATER FLOWS/6BTOTALAUXFEEDWATBt FLOWt(TRAUXILIARY FEEDWATER PlNPAttTRAU)(ILIARY FEEDWATER PU)(PBAUXFWPUt(PSTEA)tSUPP(.YVALVEAAUXFWPlNPSTEA)(SUPPLYVALVE8ATWSRXTRIPPEDi.00000+001.0000&06.13757"115.34561-11

.00934..0103.3103.0NOTTRIPNOTTRIP45.949.6.01053.580.TRIPPEDTRIPPEDTRIPPEDTRIPPEDNOTTRIPNOTTRIPNOTTRIPNOTTRIP.022.1LO)tERLONERLO)tERLOI(ERLO)tERLONERLOWERLOWERLONERLONER494.6494.6495.5487.6494.8491.0100.8492.20.182.OFFONCLOSEDCLOSEDALNALNINH)tCPSINH8CPSGOODAt(PGOODAt(PGDODXLALt(PSIGLAL)(X600DX600DXGOODGOOD600'EGFGOODXLAL)(XGOODPSIGLWR)(PSI6ALRtlALRt(ALRtlALR)(DELDELALRt(AUIGOODPSIG6009FATGOODGOOD60096000GOOD6009600DGOOD6009GOODGOODDEGF600DDEGFGOODDE6F600DDE6F6000KGF6000DEGF600DX600~DEGF600DGPttGOODGPt(6009GBQD600D6009 OCr8,1992R.E.GINASINlLATOR TRENDGROI'SSIGQKNT RNNARYPA6E2POINTID53FSIA54FGIB55P216056P216157BKR04158BKR04259BKR04360BKR044DESCRIPTION SAFETYINJECTION.LOOP AAVGFLOMSAFETYINJECTIONLOOPBAVGFLOMSERVICEMATERPIPSAhBHEADERSERVICEMATERPIIPSChDHEADERSERVICEMATERPtIPASERVICEMATERPlmPBSERVICEMATERPlIPCSERVICEMATERPUNPDVALUENILE.U.257.GOODGPtl256.GOODGPN85.GOODPSIG85.6008PSIGGOODGOODGOODGOODGROUP:EVENTiPROCEDURE:

EPIP1-5PLANTSTATUSE+J ROGRAMNAME:LRGTSZ.E R.E.GINNANUCLEARPOlERPLANTOCT08,9209:30:00TRENDGROUPASSIGNHEHT SUMMARYGROUPHAMEEVENT2GROUPDESCRIPTION PROCEDURE:

EPIP1-5PLANTSTATUSPOINTmDESCRIPTION CURRENTVALUEQUALITYCODEENGRUNITS12345678910111213142021222324252627282930313233343536373839404142430JF0619LRWSTWS033WD033WT033WT250WDT2R01R02R05R09R34R35R10AR11R12R10BR13R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14ASR14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03TCV07TCV08TCV09TCV10TCV17COMPONENT COOLINGLOOPTOTALFL'WREFUELIHG WATERSTORAGETANKLVL33FOOTLEVELWINDSPEED33FOOTLEVELWINDDIRECTION 33FOOTLEVELTEHPERATURE 250FOOTLEVELTEHPERATURE 250TO33FOOTLEVELDELTATEMPAREA1-CONTROL ROOMAREA2-CONTAIKMEHT AREA5-SPENTFUELPITAREA9LETDOWNLINEMONITORAREA34AUXBLDGCVSPRAYPUMPAREA35PASSSAMPLEPANELCONTAINMENT IODINEMONITORR10ACONTAINMENT AIRPARTICULATE CONTAIHMEHT GASMOHITORPLANTVENTIOOIHEMONITORR108AUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIQUIDWASTEDISPOSALMONITORSTEAMGEHERATOR BLOWDOWNDRAINAREA29-COHTAINMENT HIGHRANGEAREA30-CONTAINHENT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LOWRANGEGASCVVENTCHAN6-AREAGAMMACVVENTCHAN7-MIDRANGEGASCVVENTCHAN9-HIGHRANGEGASPLANTVEHTCHAN5-LOWRANGEGASPLANTVENTCHAN7-MIDRAHGEGASPLANI'ENT CHAN9HIGHRANGEGASAIREJECTORCHAN5-LOWRANGEGASAIREJECTORCHAN7-MIDRANGEGASAIREJECTORCHAN9-HlRANGEGASAREA31STEAMLINEA(SPING)AREA32STEAMLIHEB(SPIKG)CVHYDROGENCOHCEHTRATION CVBASEMENTLVL6FTTEMP¹3CVINTERMEDIATE LVL6FTTEMP¹7CVINTERMEDIATE LVL6FTTEMP¹8CVINTERMEDIATE LVL6FTTEHP¹9CVINTERMEDIATE LVL6FTTEHP¹10CVOPERATING LVL6FTTEMP¹171485.94.54.150.60.760.6-0.19.02214-02 7.35678+00 1.39946+00 1.47701+02 9.09354-01 1.09283+00 9.58719+01 5.18901+02 7.38002i02 4.30543>01 8.58327+01 4.22831+01 2.78658t03 1.57174+04 5.05861-01 5.09440-01 9.99999+06

~1.89699-07 2.53990-02 3.57435.05 1.41261.03 4.40312-07 6.86543-05 3.72621-03 9.99999.03 1.85392+00 1.85436+00 3.02040+00 1.01048.02

.095.1106.0106.6106.7106.2117.5GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODBALMGOODGOODGOODGOODGOODGOODGOODBALMHALMHWRNHALMGOODGOODGOODGOODGOODGOODGOODGOODGPMXMPHDEG.DEGFDEGFDEGFMR/HMR/HMR/HMR/HMR/HMR/HCPMCPMCPMCPMCPMCPMCPMCPHR/HRR/HRCPMUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRMR/NRXDEGFDEGFDEGFDEGFDEGFOEGF Time:Jg~)Message:~~XINNATATIN12EVALATEDEXERIEMESSAEFRM~f:RII<<C<<IRRPIIRpIIEmergency Coordinator SimulaedPlanConditions:

~Massae:"""THISISANEXERCISE"""

Declarean~LERTinaccordance withEPIP1-0,"GinnaStationEventEvaluation andClassification,"

EAL:SteamGenerator TubeRupture(SGTR);SGTR)100gpm.FORCONTROLLER USEONLY~C"'lR1)DeliveronlyifanALERThasnotbeendeclared.

DonoDeliverifEmerenClassifica iondicussionsarinrorAnticiatedResuls:1)Delivercontingency messageifALERTnotdeclaredorisnotbeingdiscussed.

Time:g)~4'jMessage:~2~IMNATATI~12EVALATEDEXEREMEAEFRM~Mf:SiI<<C<<IRSimulaedPlanCondiions:SeetheAttachedSheetsMessa<ee:

"""THISISANEXERCISE"""

FORCONTROLLER USEONLYController Noes:AniciaedResvls;1)Operators performing Applicable ActionsofE-3.2)TheRCSshouldbedepressurized torupturedS/GpressureandtheHighHeadSafetyInjection Pumpstakenoutatapproximately thistime.3)TheTSCshouldbenearingoperational readiness oftheEmergency ResponseOrganization.

4)TheTSC,whenoperational, shouldsendrepairteamsintotheAuxiliary Buildingtoevaluatethe1ACCWPumpandmotorproblems.

5)TheTSC,whenoperational, shouldsendrepairteamsouttoevaluatethe"A"and"B"S/GARVproblems, ifnotalreadydone.6)TheEOFmaybeactivating atthistimeduetoPlantconditions.

199K'EVALUATED EXERCISETime:QVVgMAZORPAEULMETERS ENGINEERED SAFEGUARDS HihHeadS.I.PumsFZ-924~GPMFI-925OGPM1A.INSERVTBOOS1B.INSERVTBOOS1C.INSERVTBOOSBASTLevel=~OSLowHeadS.I.PumsFI-626OGPM1A.INSERVOOSRECIRC1B.INSERVTBOOSRECIRCRWSTLevel=S.Containment SraPumsFI-931AGPMFZ-93IB~GPM 1A.INSERVSTBOOS1B.INSERVTBOOSNaOHTankLevel=Containment RecircFans1A.NSEVSTBYOOS1B.NSERVSTBYOOS1C.INSSTBYOOS1D.INSTBYOOSPostAccidentDampersPECLOSEDServiceWaterPums1A.SESTBYOOS1B.NSEVSTBYOOS1C.NSERSTBYOOS1D.NSSTBYOOSA&BHeaderPressureS5PSIGDIESELGENERATORS A.NINGUNLOADESTBYOOSB.RUNNINADEDSTBYOOSTSCRUNNNGADEDTBOOSSecurityRUNNINGUNLOADComonentCoolinWaterPums1A.INEVSTBY001BNSERVSTBYOOSSurgeTanvel=~2OOSENGINEERED SAFEGUARDS Aux.Feedwater Pums1A.INSERVBOOS1B.NSEVSTBYOOSTurb.DrivenERVSTBYOOSCSTLevelFEET*CET=AverageofSelectedCoreStandbAux.Feedwater Pums1C.INSERVTBOOS1D.INSERVBOOSExitThermocouples ReactorShutdownYESNON-31CPSN-32CPSN-35/.os-IAMPSN-36'-//AMPSAvg.NuclearPowerRCSPressure~FPSIGPRZRLevelye2.4ARCPSTOPPEDBRCPRUNNINSTOPPEDlAS/GLevel2.1BS/GLevel'1AS/GPressure/0/PSIG1BS/GPressure2.ZPSIGTurbine/Generator INE/4KVBusesNRGIZDEENERGIZED 480VBusesENERGIZDEENERGIZED DCBatteries A/SOVOLTSB(3OVOLTS CnmtPressure~~~FOGPSIGCnmtSumpALevel~/FEETCnmtSumpBLevelINCHESALoopHotLeg1.OFALoopColdLeg/1OFBLoopHotLeg817.OFBLoopColdLegOFRVLIS/oo.S'*CET~97.9OF.S/GATotalAuxFWFlow0GPMS/GBTotalAuxFWFlow~~SGPM 8)199209:45R.E.GINASIILATORPA6E1TRENDGROUPASSIGHNEHT SUttt(ARY 6ROUP:EVENT1PROCEDURE:

EPIP1-5POINTIDDESCRIPTION PLA)(TSTATUSE.U.12345678910111213141516f718202122232425262728293031323334353637383940414243444546474849505152ATl6RXTN31N32N35N36t(PPRCSLPZRFRCLAFRCLBRXT16RXT17TSUBTCLSGALSBBPSBAPSBBGENBKR1GEHBKR2BUS11ABUS11BBUSf2ABUS12BB11A12AB11B12BPCVLSI(PALO942ELO943ELO942DLO943DLO942CLO943CLO942BLO943BLO942ALO943ATO409AT041OATO450T0451TAVBAMIDTAVBBWIDLRVTCCOREFAUXFWAFAUXFWBBKRO81BKR082V3505V3504ANTICIPATED TRANSIENT M/0SCRAttREACTORTRIPBS(ERSTATUSSISCERANGEDETECTORN-31So(ICERANGEDETECTORN-32INTERt(EDIATE RANGEDETECTORN-35INTERt(EDIATE RAN6EDETECTORN-36AVERAGENUCLEARPOWERREACTORCOOLANTSYSTEt(AVGPRESSPRESSURIZER AVERAGELEVELREI:TORCOOLNTLOOPAAVGFLOWREACTORCOOLANTLOOPBAVBFLOWRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCORETCSUBCOOLED t)ARGINSTttGENANARROWRAHGEAVGLEVELSTt(GENBNA)SOWRANGEAVGLEVELSTHGEttAAVERAGEPRESSURESTHGENBAVERAGEPRESSUREGBHQTORONLINEBREAKER16f372GBGQTORONLINEBREAKER9X1372BUS11ASUPPLYBREAKERBUS11BSUPPLYBREAKERNOTTERNIHATED OHPPCS(7/19/91)

HOTTERNIHATED OHPPCS(7/19/91)

BUS11ATO12ATIEBRENERBUSifBTo128TIEBRENERCONTAIN)(EHT AVERAGEPRESSURECONTAItlt(EHT S)t(PAAVEIWBEi&ELSU)PBLEVEL8INCHES(TRAINA)SUtPBLEVEL8INCHES(TRAIN9)SUtP8LEVEL78INCHES(TRAINA)SUtPBLEVEL78INCHES(TRAINB)SUtPBL&EL113INCHES(TRAIN A)SUtPBLEVEL113INCHES(TRAIN B)SU)PBLEVEL180INDUS(TRAIN A)SUtPBLB(EL180INCHES(TRAIN B)SUtPBLEVEL214INCHES(TRAIN A)SUtPBLElr'EL214INCHES(TRAIN B)RCLAHOTLEGTEtlPERATSK RCLBHOTLE6TEtiPERATUliE RCLACOLDLEBTE)PERAT(BE RCLBCOLDLEGTEt(PERAT(SE RCLATAVG(THOT/TCOLD WIDERNG)RCLBTAVB(THOT/TCOLD WIDERHB)REACTORVESSELAVERAGELEVELE1.1IHCOPETCAVERAGETEt)PS/GATOTALAUXFEEDWATER FLOWS/6BTOTALAUXFEENAlrBFLOWt(TRAUXILIARY FEEDWATER PlNPAt(TRAUXILIARY FEEDWATER PUt(PBAUXFWPIN'TEA)t RFPLYVALVEAAUXFMPlNPSTEANSUPPLYVALVEBATWSRXTRIPPED8.46249+018.75988+01 1.01391-11 1.01391-11

.0010855002103.1102.5NOTTRIPHOTTRIP58.962.633.41081.622.TRIPPEDTRIPPEDTRIPPEDTRIPPEDNOTTRIPNOTTRIPNOTTRIPNOTTRIP".O92.1LO)tERLo)(ERLOWERLONERLOWERLOWERLOWERLO))ERLONERLOWER497.4497.4497.9494.6497.7496.0100.5497.4O.364.OFFONCLOSEDOPENALRNALINGOOD6009600960096009LuGoon6009Goon60096009Boo<HWRHGoon60096009ALfNALR)(ALRt(AUNDELDELALR)(ALRt(6009GOOD6009Boon600960096009600960096009600960096009600960096009600960096009GooeGOOD6009600960096009AUNPSIGPSIGPSIGFKfDEGFKGFDEBFDEGFDEGFDEGFXDEBFGNBPN OCTBi199209:45R.E.GINASINKATORTRENDGROUPASSIGNNENT SIOIRYPA6E26ROUP!EVENT1PRXEDUREl EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION VALUENNLE.U.5354555657585960FSIASAFETYINJECTION.

LOOPAAVGFLOMFSIBSAFETYINJECTION LOOPBAV6FLOWP2160SERVICEMATERPNPSA5BHEADERP2161SERVICEMATERPIIPSC5DHEADERBER041SERVICEMATERPlIPAINR042SERVICEMATERPlIPBBER043SERVICEMATERPNPCBKR044SERVICEMATERP1IPD0.600DPN0.GOODGPtl85.600DPSI685.GOODPSIGGOODGOOD600D600D 0

~~I~OGRAMNAME:LRGTSZ.E

.E.GIHNANUCLEARPOWERPLANTOCT08,9209:44:00TRENDGROUPASSIGHHENT SUMMARYGROUPNAMEEVENT2GROUPDESCRIPTION PROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURRENTVALUEDUALITYCODEENGRUNITS12345678910111213141519202122232425262728293031323334353637383940414243F0619LRWST'WS033WD033WT033WT250WDT2R01R02R05R09R34R35R10AR11R12R10BR13R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14ASR14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03TCV07TCVOBTCV09TCV10TCV17COHPONEHT COOLINGLOOPTOTALFLWREFUELING WATERSTORAGETANKLVL33FOOTLEVELWINDSPEED33FOOTLEVELWINDDIRECTION 33FOOTLEVELTEHPERATURE 250FOOTLEVEL,TEMPERATURE 250TO33FOOTLEVELDELTATEMPAREA1-CONTROL ROOMAREA2-CONTAINMEHT AREA5-SPENTFUELPITAREA9.LETDOWN LINEMONITORAREA34-AUXBLDGCVSPRAYPUMPAREA35-PASSSAHPLEPANELCONTAINMENT IODINEMONITORR10ACONTAINHENT AIRPARTICULATE CONTAINMENT GASMONITORPLANTVEHTIODINEHONITORR108AUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGAS'MONITOR LIQUIDWASTEDISPOSALMONITORSTEAMGENERATOR BLOWDOWNDRAINAREA29-CONTAINMEHT HIGHRANGEAREA30-CONTAIHMEHT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5LOWRANGEGASCVVENTCHAN6-AREAGAMMACVVENTCHAH7-MIDRANGEGASCVVENTCHAN9HIGHRANGEGASPLANTVENTCHAN5-LOWRANGEGASPLAHTVENTCHAN7-MIDRANGEGASPLANTVENTCHAN9-HIGHRANGEGASAIREJECTORCHAH5-LOW'RAHGEGASAIREJECTORCHAN7-MIDRANGEGASAIREJECTORCHAH9-HIRANGEGASAREA31STEAMLINEA(SPING)AREA32STEAMLIHE8(SPIHG)CVHYDROGENCONCENTRATION CVBASEMEHI'VL 6FTTEMP¹3CVINTERMEDIATE LVL6FTTEMP¹7CVIHTERHEDIATE LVL6FTTEHP¹8CVINTERMEDIATE LVL6FTTEHP¹9CVINTERMEDIATE LVL6FTTEMP¹10CVOPERATING LVL6FTTEHP¹171485.94.54.949.61.361.30.09.02214-02 7.35678i00 1.3994&001.47701+02 9.09354.01 1.09283+00 9.58719+01

.5'8901+027.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658+03 1.57174+04 5.05861.01 5'9440.014.40835i06 1.89699-07 2.53990-02 3.57435-05 1.41261-03 4.40312.07 6.86543-05 3.72621-03 9.99999-03 2.20392-01 2.20436-01

3.0 2040100

1~01048-02~095.1106.0106.6106.7106.2117.5G(a)GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODBALMGOODQXOHALMGOODGOODGOODGOODGOODGOODGOODHALMBALMGOODHALMGOODGOODGOODGOODGOODGOODGOODGOODGPMXMPHDEG.DEGFDEGFDEGFMR/HMR/HMR/HMR/HMR/HMR/HCPMCPHCPMCPHCPMCPMCPMCPMR/HRR/HRCPMUCI/CCHR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRMR/HRXDEGFDEGFDEGFDEGFDEGFDEGF$-/03 Time:~1QQMessage:~2)~INNATATION12VALEDEXEIEMEAEFRM~i:8*iiylAiliWDi<<IChiiidiihiiiiiiisite,connection andoperation ofIVlobileDlUnit.imIPlnniin:SeeAttachedMini-Scenarios

~M~a:"'THISISANEXERCISE"'

RNTLLERENLYN1)Provideinformation verballywhenappropriate actionsaresimulated orinvestigations aremadebytheappropriate players.E1)AsperattachedIVlini-Scenarios F-/o33 INNATATIN12EVALAEDEEEMINI-CENARI~A~iviy:BringingMobileDlUnitOnSite(Security)

FORONTRLLERSEONLYN1)At1000SecurityController willinformGuardHousepersonnel thatthereisaSimulated MobileDlUnitTraileroutfrontofGuardHouseanditneedstocomeonSite,~AiE1)Securitypersonnel shouldinformTSCandSimulateprocessing theDlTruckonSiteExpeditiously.

NAATI12EVALATEDEXERIEMINI-CENARIOhg~iviy:Connection andOperation ofMobileDlUnit(Auxiliary OperatorandChemist).

FRNTROLLERSEONLYonrollerN1)Auxiliary OperatorandChemistshouldbenotifiedbytheTSC/CRthattheMobileDIUnithasarrivedandneedstobeconnected andputinoperation.

2lInformAuxiliary Operator~AT103thatheistoSimulatestoppumpingfromoutsidestoragetanktoinsidestoragetankbecauseoutsidestoragetankisempty.AlsotheMobileDl'nitshouldbereadytooperateinaboutanhour.3)InformAuxiliary Operatorjustprio'rto1120thatheistoSimulatepumpingwaterh1kd<<gk~AgkkgAionsEx1)'uxiliary OperatorandChemistshouldSimulateconnecting theMobileDlUnitperprocedure T-6.13.TobeSimulated pumpingtooutsidestoragetank~T~111hr.2)Auxiliary OperatorshouldinformTSC/CRthattheoutsidestoragetankisemptyandhehasstoppedpumping.AlsothattheMobileDlUnitwillbeinoperation inaboutanhour.3)Auxiliary Operatorshouldsimulatestartingtotransferwaterfromtheoutsidestoragetanktotheinsidestoragetanksperprocedure T-6.12at~112hr.4)Auxiliary OperatorshouldnotifyTSC/CRthatheisstartingtofilltheinsideCondensate Storagetanks.

Time:~1QQMessage:~2INNATATIN2EVALATEDEXEIEMEAGEFRMCI<<CICimlaPlnniin:SeetheAttachedSheets~Mesae:"""THISISANEXERCISE"""

FORCONTROLLER USENLY~C"'C1)TheDltruckarrivesonSiteAniciaeRsuls:1)Operators performing theApplicable ActionsofE-3.2)TheTSCshouldbeassumingcommandandcontrolatapproximately thistime.

199'VALUATED EXERCISETime:~/GGMAZORPAEVLMETERS

'NGINEERED SAFEGUARDS ReactorShutdownQ~ES)NON-31~~CPSN-32CPSN-35i.oe-IAMPSN-36-llAMPSAvg.NuclearPoweroRCSPressure073PSIGPRZRLevelARCPRUNNINGTOPBRCPSTOPPED1AS/GLevel1BS/GLevel~'841AS/GPressure~d7PSIG1BS/GPressure2.~PSIGTurbine/Generator ONLINE/FLIN4KVBusesNERGIZDEENERGIZED 480VBusesNERGIZEDEENERGIZED DCBatteries AtSOVOLTSB/BOVOLTSCnmtPressure/7PSIGnmtSumpALevel2.IFEETCnmtSumpBLevelINCHESALoopHotLegOFALoopColdLegOFBLoopHotLegf4.IOFBLoopColdLeg~2OFRVLIS*CETfV4.24F3/GATotalAuxFWFlow~GPMS/GBTotalAuxFWFlow~13.GPMHihHeadS.I.PumsFI-924.GPMFI-925QGP1A.INSERVOOS1BINSERVTBOOS1CINSERVTBOOSBASTLevel=~pOOSOOSContainme RecircFans1A.INSERSTBYOOS1B.SSTBYOOS1C.NSERSTBYOOS1D.NSERSTBYOOSPostAccidentDampersPEServiceWaterPums1A.NSERSTBYOOSLowHeadS.I.PumsFI-626ClGPM1A.INSERVTOOSRECIRC1BINSERVTBOOSRECIRCRWSTLevel=~E.Containment SraPumsFI-931A0GPMFI-931B0GPM1A.INSERVB1B.INSERVTBNaOHTankLevel=CLOSEDDIESELGENERATORS A.RUNNINGUNLOADEDTOOSB.RUNNINGUNLOADEDBOOSTSCRUNNINGUNLOADEDTBOOSSecurityRUNNINGUNLOADEDTBENGINEERED SAFEGUARDS Aux.Feedwater Pums1A.INSERVTBOOS1B.NSERSTBYOOSTurb.DrivenINSERVTBOOSCSTLevelFEETOOS1B.SRSTBYOOS1C.NSESTBYOOS1D.SEVSTBYOOSA&BHeaderressurefhPSIGComonentCoolinWaterPums1A.INSERVSTBY01B.NSERSTBYOOSSurgeTanvel=~L-StandbAux.FeaterPums1C.INSERVTBOOS1D.INSERVTBOOS*CET=AverageofSelectedCoreExitThermocouples Bs199210:00R.E.GINASit(ULATOR TRENDGIPASSIGI(Et(T SUt(t(ARY PAGE11234567810111213IS1617181920212223242526272829303132343536373839404142434445464748495051526ROUP:EVENTiPROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDATMSRXTN31N32N35N36NPPRCSLPIRFRCLAFRCLBRXT16RXT17TSUBTCLSBALSBBPSBAPSGBGENBKRlGENBKR2BUS11ABUS11BBUS12ABUS12BB11A12ABIIB129PCVLS(NPAL0942EL0943EL0942DL0943DL0942CL0943CL09428L0943BL0942AL0943AT0409AT0410AT0450T0451TAVGAMIDTAVGBMIDLRVTCCOREFAUXFWAFAUXFWBBKR081BKR082V3505V3504DESCRIPTION ANTICIPATED TRANSIENT W/0SCRAttREACTORTRIPBREAKERSTATUSSolSCERANGEDETECTORN-31SISCERANGEDETECTORN-32INTEf(t(EDIATE RANGEDETECTORN-3SINTER)(EDIATE RANGEDETECTORN-36AVERAGENUCLEARPOWERREACTORCOOLANTSYSTE)(AVGPRESSPRESSURIIER AVERAGELEVELREACTORCOOLANTLOOPAAVGFLOWREACTORCOOLANTLOOP8AVGFLOWRCPABREAKERCAUSERrTRIPRCPBBREAKERCAUSERXTRIPINCORETCSUBCOOLED t(ARGINSTt(GENANARROWRANGEAV6LEVELST)(GENBNARROWRANGEAVGLEVELSTt(GENAAVERAGEPRESSURESTHGENBAVERAGEPRESSUREGBERATORONLINEBREAKER161372BBGQTORONLINEBREAKER9)(1372BUS11ASUPPLYBREAKERBUS11BSIPPLYBREAKERNOTTERt(I@ATED ONPPCS(7/19/91)

NOTTERt(INATED ONPPCS(7/19/91)

BUS11ATO12ATIEBREA(ERBUS11BTO128TIEBREIERCONTAIN)(ENT AVERAGEPRESURECONTAINt(ENT SUt(PAAVE)mGELEVELSU)P8LEVEL8INCHES(TRAINA)SU)PBLEVEL8It/CHES(TRAINB)SU)PBLEVEL78INCHES(TRAINA)SUtPBLEVEL78INCHES(TRAINB)SUtPBLEVEL113INCHES(TRAIN A)SUtPBLEVEL113INCHES(TRAIN B)SUtPBLEVEL180INCHES(TRAIN A)SUtPBLEVEL180INCHES(TRAIN B)SU)PBLEVEL214INCHES(TRAIN A)SUtPBLEVEL214INCHES(TRAIN B)RCLAHOTLEGTEt(PERATURE RCLBHOTLEGTBlPERATURE RCL4COLDLEGTEt(PERAT(BE

'RCLBCOLDLEGTEt(PERAT(RE RCLATAVG(THOT/TCOLD WIDERNG)RCLBTAVG(THOT/TCOLD WIDERNG)REACTORVESSELAVERAGELEVELEl.1INCORETCAVERAGETEt(PS/GA:OTALAUXFEEDMATWFLOWS/69TOTALAUXFEEDVAmFLOWt(TRAU)(ILIARY FEEDMATER PUtFAt(TRAU)(ILIARY FEEDMATER PU)(PBAUXFWPUt(PSTEAtlSUPPLYVALVEAAUXFWPlIPSTEA)tSLR'LYVALVEBATNSRXTRIPPED8.52117+01 8.8206801 1.01391"Ii 1.01391-11

.001073.51.512.3106.9TRIPPEDNOTTRIP58.760.449.31067.622.TRIPPEDTRIPPEDTRIPPEDTRIPPEDNOTTRIPNOTTRIPNOTTRIPNOTTRIP-.172.1LONERLONERLONERLONERLONER.LONERLONERLONERLONERLONER493.9496.1O'.2494.2494.1495.299.6496.20.129.OFFCLOSEDCLOSEDALRNALRt(60096009600960096009LALt(6009INHB600DALR)(6009BooeHNRt(60096009GOODALRlALRt(ALRt(ALRt(DELDELAUIALRt(6009600960096009600960096009BOOB600960096009600960096009600960096009GOODBM9600960096009E.U.CPSCPSAt(PXPSIGXXXDEGFX'XPSIGPSIGKGFDEBFDEGFDEGFKGFDE6FDEGFGPt(9%

OCT8~89210:00R.E.GINASitSLATNTREND6IIPASSIGNMENT QNNRYPAGE26ROUP:EVENTiPROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION NLUEQNLE.U.53FSIA54FSIB55P216056P216157BKR04158BKR04259BKR04360BKR044SAFETYINJECTION.

LOOPAAVGFLOWSAFETYINJECTION LOOPBAVGFLOWSERVICEWATERHIPSAhBHEADERSERVICEWATERPNPSC5DHEADERSERVICEWATERPNPASERVICEWATERPIIPBSERVICEWATERPllPCSERVICEWATERPlIP90.6009Ptl0.6009GPN85.6009PSI685.600DPSI660096009600D6009

~~I~ROGRAMNAME:LRGTSZ.E

.E.GIKHANUCLEARPOWERPLANTOCT08,9210:00:00TRENDGROUPASSIGKHENT SUMHARYGROUPNAHEEVENT2GROUPDESCRIPTION PROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURRENTVALUEDUALITYCODEENGRUNITS23456789101112131420212224252627282930313233343536373839404142430JF0619LRWSTWS033WD033WT033WT250WDT2R01R02R05R09R34R35R10AR11R12R108R13R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14A5R'I4A7R14A9R15A5R15A7R15A9R31R32CVNTCV03TCV07TCVOBTCV09TCV10TCV17COMPONENT COOLINGLOOPTOTALFLWREFUELING WATERSTORAGETANKLVL33FOOTLEVELWINDSPEED33FOOTLEVELWINODIRECTION 33FOOTLEVELTEMPERATURE 250FOOTLEVELTEMPERATURE 250TO33FOOTLEVELDELTATEMPAREA1-CONTROL ROOMAREA2-CONTAINMENT, AREA5SPENTFUELPITAREA9-LETDOWN LINEMOHITORAREA34-AUXBLDGCVSPRAYPUHPAREA35-PASSSAMPLEPANELCOHTAINMEHT IODINEMONITORR10ACONTAINMENT AIRPARTICULATE CONTAINHENT GASMONITORPLANTVENTIODINEMONITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIDUID'WASTEDISPOSALMONITORSTEAMGENERATOR BLOWDDWNDRAINAREA29-CONTAINMENT HIGHRANGEAREA30-CONTAINHENT HIGHRAHGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LOWRANGEGASCVVENTCHAN6-AREAGAMHACVVENTCHAN7-HIDRANGEGASCVVENTCHAN9-HIGHRANGEGASPLANTVEHTCHAN5-LOWRANGEGASPLANtVENTCHAN7MIDRANGEGASPLAN'IVENTCHAN9-HIGHRANGEGASAIREJECTORCHAN5-LOWRANGEGASAIREJECTORCHAN7-MIDRANGEGASAIREJECTORCNAH9-HlRANGEGASAREA31STEAHLIHEA(SPING)AREA32STEAMLINE8(SPING)CVHYDROGENCONCENTRATION CVBASEHENTLVL6FTTEMP¹3CVINTERMEDIATE LVL6FtTEHP¹7CVINTERMEDIATE'LVL 6FTTEMP¹8CVINTERMEDIATE LVL6FTTEHP¹9CVIHTERMEDIATE LVL6FtTEMP¹10CVOPERATING LVL6FTTEMP¹171485.94.55.055.61.36140.19.02214-02 7.35678+00 1.39946+00 147701+029.09354-01 1.09283+00 9.58719+01 5.18901+02 7.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658+03 1.57174+04 5.05861.01 5.09440-01 1.57835+03 1.89699.07 2.53990-02 3.57435-05 1.41261-03 4.40312-07 6.86543-05 3.72621-03 2.09411-07 1.34492051.27941-03 3.02040+00 1.01048-02

~095~1106.0106.6106.7106.2117.5G(XSGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODBALMGOODGOOD.GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODNALHGOODGOODGOODGOODGOODGOODGOODGOOD.GPMMPHDEG.DEGFDEGFDEGFMR/HMR/HMR/HHR/HMR/MMR/HCPHCPHCPMCPMCPMCPMCPHCPMR/HRR/HRCPHUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRMR/NRDEGFDEGFDEGFDEGFDEGFDEGF Time:~1~1Message:~g~INNATATIRN12EVALATEDEXERIE~MESAEFRM~IIII:MI<<RIRSimulaedPlantCondition:

SeetheAttachedSheets~Messee:"""THISISANEXERCISE"""

Thefollowing annunciator isreceived:

~J-9(Safeguard BreakerTrip)FORCONTROLLER USEONLYController Notes:1)Whenoperators checktheControlBoard,informthemthatthe"A"SWPumpswitchindicates awhitelightandthe"A"SWPumpindicates tripped.lfoperators trytorestartpumpbecauseofSl,itwillnotrestart.AniciaedReuls:1)Operators performtheApplicable ActionsofAR-J.9.2)Operators shouldinformTSCof"A"SWPumpproblem.3)Operators/TSC shouldsendanAuxiliary OperatortotheScreenhouse tocheckonthe"A"SWPump.4)Operators performing theApplicable ActionsofE-3.

199KEVALUATED EXERCISETime:~biSENGINEERED SAFEGUARDS HihHeadS.I.PumsMAJORPAEULMETERS

.'eactorShutdownN-31N-32N-35N-36Avg.NuclearPowerRCSPressurePRZRLevelARCPBRCP1AS/GLevel1BS/GLevel1AS/GPressure1BS/GPressureTurbine/Generator 4KVBuses480VBusesDCBatteries APOCnmtPressureCnmtSumpALevelCnmtSumpBLevelALoopHotLegALoopColdLegBLoopHotLegBLoopColdLegRVLIS*CETS/GATotalAuxFWS/GBTotalAuxFWESNOFI-924~GPMFI-925~GPM1A.INSERVTBOOS1B.INSERVBOOS1C.ZNSERVTBOOSBASTLevel=/OCPS.E-sAMPS.~oI-AMPS0OP<7PSIG>4lgRUNNINGTOPPEUNNINGSTOPPEDS.~4~IO7PSIG2.~PSIG0LINERGIZEDEENERGIZED ERGIZEDEENERGIZED

~VOLTSB/3OVOLTS-oI0PSIG~2.~eFEETINCHES'fgeOF~1'i~OF~6~40FOFFlow~GPMFlow~~GPMLowHeadS.Z.PumsFZ-626GPM1A.INSERVTBOOSRECIRC1B.INSERVTBOOSRECIRCRWSTLevel=~~4Containment SraPumsFZ-931A0GPMFI-931BC9GPM1A.INSERVTBOOS1B.INSERVTOOSNaOHTankLevel=Containment RecircFans1A.NSERSTBYOOS1B.NSSTBYOOS1C.INSESTBYOOS1D.NSESTBYOOSPostAccientDampersPECLOSEDServiceWaterPums1A.INSERVSTBY01B.SSTBYOOS1C.ERSTBYOOS1D.NSERSTBYOOSA&BHeaderPressure70PSIGComonentCoolinWaterPumsDIESELGENERATORS A.RUNNINGUNLOADEDTBOOSB.RUNNINGUNLOADEDTBOOSTSCRUNNINGUNLOADEDOOSSecurityRUNNINGUNLOADEDTBOOS1A.INSERVSTBYOS1B.ERVSTBYOOSSurgeTanvel=ENGINEERED SAFEGUARDS StandbAux.Feedwater Pums1C.INSERVTBYOOS1D.INSERVOOSAux.Feedwater Pums1A.INSERVTOOS1B.NSERSTBYOOSTurb.DrivenINSERVTBOOSCSTLevelFEET*CET=AverageofSelectedCoreExitThermocouples 8i199210:14R.E.GINASINULATOR PAGE1TRENDGROUPASSIGNNE)(T SUNNARYGROUP:EVENT1PROCEDURE:

EPIP1-5PLANTSTATUS1235678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152POINTIDATWSRXTN31N32N35N36NPPRCSLPZRFRCLAFRCLBRXT16RXT17TSUBTCLSBALSGBPSGAPSGBGENBKR1GENBKR2BUS11ABUS118BUS12ABUS128811AI2A8118128PCVLSlNPAL0942EL0943EL0942DL0943DL0942CL0943CL09428L09438L0942AL0943AT0409AT0410AT0450T0451TAVGAWIDTAVGBWIDLRVTCCOREFAUXFWAFAUXFWBBKR081BKR082V3505V3504DESCRIPTION ANTICIPATED TRANSIENT W/0SCRANREACTORTRIPBREAKERSTATUSSIKERANGEDETECTORN-31SMCERANGEDETECTORN-32INTERNEDIATE RANBEDETECTORN-35INIERNEDIATE RANGEDETECTORN-36AVERAGENUCLEARPOWERREACTORCOOLANTSYSTENAVGPRESSPRESSURILER AVERAGELEVELREACTORCOOLANTLOOPAAVGFLOWREACTORCOOLANTLOOP8AVGFLOWRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCORETCSUBCOOLED t%5INSTNGENANARROWRANGEAVGLEVELSTNGEN8NARROWRANGEAVGLEVELSTN6ENAAVERAGEPRESSURESTNGEN8AVERAGEPRESSUREGBGQTORONLINEBREAKER161372BBGQTORONLINEBREAKER9X1372BUS11ASUPPLYBREAKERBUS118SUPPLYBREAKERNOTTERNINATED ONPPCS(7/19/91)

NOTTERNINATED OttPPCS(7/19/91)

BUSliATO12ATIEBREAKERBUS118To128TIEBRENERCONTAIt(NENTAVERAGEPRESSURECONTAINNENT PJNPAAVERAGELEVELSUtP8LEVEL8INCHES(TRAINA)SUtPBLEVEL8It(CHES(TRAIN8)SUtP'LEVEL78It<CHES(TRAINA)SSP8LEVEL78INQ!ES(TRAIN8)SUNUP8LEVEL113INCHES(TRAIN A)SUti'LEVEL113INCHES(TRAIN 8)SUtP8LEVEL180INCHES(TRAIN A)SUtP8LEVEL180INCHES(TRAIN 8)SUtl-'LE'<re214INCHES(TRAIN A)SUtP8LEVEL214INCHES(TRAIN 8)RC(AHOTLEGTENPERATSK RCLBHOTLEGTENPERATURE RCLACOLDLEGTENPERATlBE RCLBCOLDLEGTE)(PERAT(BE RCLATAVG(THOT/TCOLD WIDERNG)RCLBTAVG(THOT/TCOLD WIDERNB)REACTORVESSELAVERAGELEVELE1.1It'CORETCAVERAGETENPS/6ATOTALAUXFEEDMATER FLOWS/G8TOTALAUXFEEDWATER FLOWNTRAUXILIARY FEEDWATER PUt(PANTRAUXILIARY FEEDMATER PUNP8AUXFWPlIPSTEANSUPPLYVALVEAAUXFWPU5'TEANSUPPLYVALVE8ATWSAUIRXTRIPPEDALRN8.91247%1 600D9.00531401 60091.01391-11 60091.01391-11 6009.0060091084.LALN42.7600912.3INHB106.96009TRIPPEDALRtlNOTTRIP600960.5600'3.2HWRt(48.1GO091078.6009622.6009TRIPPEDAUITRIPPEDALRNTRIPPEDALRtfTRIPPEDAUINOTTRIPDELNOTTRIPDELNOTTRIPALRtfNOTTRIPALRN".1960092.26009LOWERG009LONER6009LOWERGOODLOMER6009LOWER6009LOMER6009LOWER6009LOWER6009LOWER6009LOMER6009493.5GOOD495.76009493.86009494.06009493.76009494.8600999.66009495.7600e0.6009197.6009OFFG009ON6(I9CLOSED6009CLOSED6009g-'/I/E.U.CPSCPSANPANPXPSIGXXXDEGFXPSI6PSIGDE6FKGFDEBFDE6FDE6FDEBFDEGFPN6PN XTGs199210:14R.E.GIN@SIRLATORTRENDGm'SSIGlST RNNSYPAGE2GROUPSEVENT1PROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION VALUEQUALE.U.53FSIA54FSIB55P21b05bP21biBKR04158BKR04259BKR043b0BKR044SAFETYINJECTION LOOPAAVGFLNSAFETYINJECTION LOOP8AVGFLONSERVICE@TERPlNPSA58HEADERSERVICENTERPIWPSChDHEADERSERVICEHATERPNPASERVICEHATERPNP8SERVICEWTERPuPCSERVICEWTERPNP0OFFONONON0.600DGPM0.600DGPN72.600DPSI680.GOODPSIG6009600DGmGOODE+J

~~~ROGRAMKAME:LRGTSZ.E

.E.GINNAKUCLEARPOKERPLANTOCT08,9210:16:00TRENDGROUPASSIGNMEHT SUHHARYGROUPNAHEEVENT2GROUPDESCRIPTIOH PROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTIONCURRENTVALUEQUALITYCODEENGRUNITS1234567891011121314202122232425262728293031323334353637383940414243-F0619LRIISTIIS033M0033MT033lIT250IIDT2R01R02R05R09R34R35'10AR11R12R108R13R14R18R19R29R30R15R12ASR12A6R12A7R12A9R14ASR14A7R14A9R15ASR15A7R15A9R31R32CVHTCV03TCV07TCVOBTCV09TCV10TCV17COMPONENT COOLINGLOOPTOTALFLUREFUELING iIATERSTORAGETANKLVL33FOOTLEVELNIKDSPEED33FOOTLEVELKINDDIRECTION 33FOOTLEVELTEMPERATURE 250FOOTLEVELTEHPERATURE 250TO33FOOTLEVELDELTATEMPAREA1-COHTROL ROOMAREA2-CONTAINHENT AREA5-SPENTFUELPITAREA9-LETOOMN LINEHOHITORAREA34-AUXBLDGCVSPRAYPUMPAREA35-PASSSAHPLEPANELCONTAINMENT 1001HEMONITORR'10ACONTAIHHENT AIRPARTICULATE COHTAINHENT GASMOHITORPLANTVENTIOOIKEHOHITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASHONITORLIQUIDUASTEDISPOSALMONITORSTEAMGENERATOR BLOMDOMNDRAINAREA29-CONTAINHENT HIGHRANGEAREA30-CONTAINMENT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LOURAHGEGASCVVENTCHAN6-AREAGAMMACVVENTCHAN7-HIDRANGEGASCVVENTCHAN9-HIGHRANGEGASPLANTVENTCHAN5-LO1IRANGEGASPLANTVENTCHAN7MIDRANGEGASPLANTVENTCNAH9-HIGHRANGEGAS'IREJECTORCHAN5-LOMRANGEGASAIREJECTORCHAN7-HIDRANGEGASAIREJECTORCHAN9-HIRANGEGASAREA31STEAHLINEA(SPING)AREA32STEAMLINE8(SPIKG)CVHYDROGENCOHCENTRATION CVBASEHEHTLVL6FTTEMP¹3CVINTERHEDIATE LVL6FTTEMP¹7CVINTERMEDIATE LVL6FTTEMP¹8CVINTERMEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEHP¹10CVOPERATIHG LVL6FTTEHP¹171485.94.54.980.61.363.32.09.02214-02 7.35678+00 1.39946+00 1.46701+02 9.09354-01 1.09283+00 9.58719+01 5.18901+027.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658+03 1.52174+04 5.05861-01 5.09440-01 1'7835+031.89699-07 2.53990-02 3.57435-05 1.41261-03 4.40312-07 6.86543.05 3.72621-03 2.09411-07 1.34492-05 1.27941-03 2.90040+00 1.01048.02

.095.1106.0106.6106.7106.2117.5600060006000GOODGOODGOODGOQOGOODGOOD6000GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOOD6000GOODGOODGOODGOODGOODGOODGOODGOODHALM6000GOODGOODGOODGOODGOODGOODGPMXMPHDEG.DEGFDEGFDEGFMR/HMR/HHR/HMR/HMR/HMR/HCPMCPMCPHCPMCPMCPMCPHCPMR/HRR/HRCPMUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRMR/HRXDEGFDEGFDEGFDEGFDEGFDEGF Time:~1~1Message:~1~l~NATATIN2EVALATEDEXERIEMEAEFRM~Mf:ASNAP<<SANSI'ASWaterPumptripproblem.SimladPlanCondiins:SeetheAttachedMini-Scenario

~Messee:"""THISISANEXERCISE"""

FORCONTROLLER USEONLYController Notes:1)Provideinformation verballywhenappropriate actionsaresimulated orinvestigations aremadebytheAuxiliary OperatorsenttotheScreenhouse tocheckthe"A"SWPumptripproblem.AnticiaedResults:1)AsperMini-Scenario Anticipated Results.

INATATIN12EVALUATED EXERISEMINI-ENARIAc1~iviy:"A"ServiceWaterPumptrippingoutproblemcheckout.FORCONTROLLER USEONLYController Notes:tiWhenAuxiliary Operatorchecksthe"A"SWPump,~infrmthepumpappearsnormal.2iIfAuxiliary Operatorchecksthe"A"SWPumpElectrical Breaker,~infrmhimthatitappearsnormal.3)GodirectlytotheGasLeakDetection IVlini-Scenario.

AnticiaedReuls:1)Auxiliary Operatorshouldcheckthe"A"SWPumpmotorforheat(i.e.,bytouchingmotor)andforodor(i.e.,bysmelling).

2)Auxiliary OperatorshouldinformControlRoom/TSCofresultsofthe"A"SWPumpinspection.

Time:~1'essage:

~2INNATATINTEDEEEMEAEFRIVI~Mt:Aill~OpiEt,didiIitNaturalGasleak.SimulaedPlnCondiions:SeetheAttachedMini-Scenario

~Messse:"""THISISANEXERCISE"""

FORCONTROLLER USEONLYController Note:1jProvideinformation verballywhenappropriate actionsaresimulated orinvestigations aremadebytheAuxiliary OperatorsenttotheScreenhouse tocheckthe"A"SWPumptripproblem.AniciatedResults:1)AsperMini-Scenario Anticipated Results.

INNATATIN12EVALUATED EXERIEININI-CENARI~A~Iviif:Screenhouse Flammable GasLeakDetection andIsolation FORCONTROLLER USEONLY1)~WhnAuxiliary OperatorenterstheScreenhouse andchecksthe"A"SWPumpmotor,~infrmhimthatthereisaverystrongodorofgaswhereheisstanding.

2)~WhntheAuxiliary OperatorcheckstheBasementoftheScreenhouse,

~infrmhimthatthereisahissingsoundcomingfromtheceiling.AniciatedResults:1)Auxiliary OperatorshouldinformControlRoom/TSCofthestrongodorofgasbythe"A"SWPumpandthestrongerodorofgasandthehissingsoundintheBasementoftheScreenhouse.

2)~Whnrequested byControlRoom/TSCtoisolateNaturalGasandpropanegastoScreenhouse, Auxiliary Operatorwillsimulatethefollowing:

a)ClosingtheGasShutoffforNaturalGastotheScreenhouse (V7229A)locatedjustoutsideofScreenhouse, southeast corner.b)ClosingtheGasShutoffsontopofthepropanetankssupplying theScreenhouse locatedwestofScreenhouse.

3)Auxiliary OperatorshouldinformControlRoom/TSCofisolation ofgastotheScreenhouse.

Time:~1'essage:

~3INNATATIN12EVALTEDEEEMEAEFRMMMMf:8I1.'<<IRSimulaedPlanCondiions:SeetheAttachedSheets~Mssss"""THISISANEXERCISE"""

FORCONTROLLER USEONLYAnticiatedResults:1)Operators performing theApplicable ActionsofE-3.2)ControlRoom/TSC, wheninformedofthegasleakintheScreenhouse, shouldrequesttheAuxiliary OperatortoisolateallsourcesofgastotheScreenhouse.

3)ControlRoomshouldcommunicate withtheTSConthegasproblemintheScreenhouse.

4)Ifnotalreadyisolated, theControlRoom/TSCshouldsendanAuxiliary Operatortoisolatethe"B"S/GARVwhenrequested todoso.(continued onthenextpage) 5)TSC,afterassessing Plantconditions,should declareaITEAEAEMERENYinaccordance withEPIP1-0,"GinnaStationEventEvaluation andClassification,"

EAL:HazardsBeingExperienced orProjected; EntryofUncontrolled Flammable GasesintoVitalAreas.Appropriate notification shouldbemadeperEPIP1-5(Notifications) and0-9.3(NRC,StateandCountiesImmediate Notification).

6)TSCshouldinformtheEOFofPlantConditions andtheSITEAREAEMERGENCY declaration.

7)ASiteEvacuation shouldbecommenced ifitisdetermined necessary.

8)RepairteamsentouttochecktheCCWPump,shouldreportthe1ACCWPumpMechanical Sealneedsreplacing andthattheIACCWPumpmotorneedstobecleanedanddriedorreplaced.

Theyreporttheserepairswilltakeapproximately eight(8)hours.Theyalsoreportthatthe1BCCWPumpMechanical Sealisleakingasmallamount.9)Repairteamsentouttocheckthe"A"S/GARVcontrolproblemshouldreportthattheARVsMercoidController needstobereplaced, Theyreportthatitwilltakeapproximately one(1)hourtorepairit.10)Ifnotalreadydone,theRepairTeamsentouttocheckthe"B"S/GARVsteamleakshouldrequestthatitbeisolated.

1992'VALUATED EXERCISETime:103>MAZORPAEULMETERS ENGINEERED SAFEGUARDS A.RUNNINGUNLOADEDTBOOSB.RUNNINGUNLOADEDTBOOSTSCRUNNINGUNLOADEDTBOOSSecurityRUNNINGUNLOADEDTBENGINEERED SAFEGUARDS OOSAux.Feedwater Pums1A.INSERVTBOOS1B.SESTBYOOSTurb.DrivenINSERVTBOOSCSTLevel~FEET*CET=AverageofSelectedCoreReactorShutdownYESNON-312.CPSN-32~CPSN-35I.es(IA-MPSN-36IIA-MPSAvg.NuclearPoweroRCSPressureO7O7PSTGPRZRLevel3ARCPRUNNINGTOPPEDBRCPUNNZNSTOPPED1AS/GLevelt'e~41BS/GLevel~svlAS/GPressure07/PSIG1BS/GPressurePSIGTurbine/Generator ONLINEFFLI4KVBusesNERGIZDEENERGZZED 480VBusesRGDDEENERGIZED

'DCBatteries A~OVOLTSBIMVOLTSCnmtPressure~LlPSIGCnmtSumpALevelFEETCnmtSumpBLevelINCHESALoopHotLeg~iMQOFALoopColdLegVVFBLoopHotLeg~HiS:OFBLoopColdLeg'fsI0OFRVLIS~V.*CETM9'S;7OFS/GATotalAuxFWFlowOGPMS/GBTotalAuxFWFlow~AFGPMDIESELGENERATORS HihHeadS.I.PumsFI-924OGPMFI-925C)GPM1A.INSERVT1B.INSERV1C.INSERVBASTLevel=OOSOOSBOOSLowHeadS.I.PumsFZ-626GPM1A.INSERVTBOOSRECIRC1B.INSERVTBOOSRECIRCRWSTLevel=3.Containment SraPumsFI-931A&GPMFI-931BC)GPM1A.INSERVTOOS1B.INSERVSBOOSNaOHTankLevel=Containment RecircFans1A.NSESTBYOOS1B.SESTBYOOS1C.SESTBYOOS1D.SERSTBYOOSPostAccidentDampersOPECLOSEDServiceWaterPums1A.INSVSTBY01B.SSTBYOOS1C.NSERSTBYOOS1D.NSERSTBYOOSA&BHeaderressure~~bPSZGComonentCoolinWaterPums1A.INSERVSTBY01B.NSERSTBYOOSSurgeTankLevel=~'fStandbAux.Feedwater Pums1C.INSERVSTOOS1D.INSERVSTBOOSExitThermocouples 8i199210:30R.E.GINASIWLATORTRENDGRI)PASSIGN)(ENT SU)tt(ARY PAGE16ROUP:EVENT1PROCEDURE'PIP I<PLANTSTATUS12356789101112131415161718202122232425262728293031323334353637383940414243444546474849505152POINTIDATKiRXTN31N32N35N36NPPRCSLPLRFRCLAFRCLBRXT16RXT17TSUBTCLSGALSGBPSGAPS6BGENBKRlGENBKR2BUSllABUS11BBUS12ABUS128Bi1A12AB11B12BPCVLSRlPAL0942EL0943EL0942DL0943DL0942CL0943CL0942BL0943BL0942AL0943AT0409AT0410AT0450T0451TAVGAMIDTAVGBMIDLRVTCCOREFAUXFMAFAUXFMBBKR081BKR082V3505V3504DESCRIPTION ANTICIPATED TRANSIENT M/0SCRAt(REACTORTRIPBRENERSTATUSSMICERA)(GEDETECTORN-31SONCERAN6EDETECTORN-32INTER)(EDIATE RANGEDETECTORN-35INTER)(EDIATE RANKDETECTORN"36AVERAGENUCLEARPOMERREACTORCOOLANTSYSTE)fAVGPRESSPRESSURIZER AVERAGELEVELREACTORCOOLANTLOOPAAVGFLOMREACTORCOOLANTLOOP8AVGFLOMRCPABREAKERCAUSERXTRIPRCPBBRENERCAUSERXTRIPINCORETCSUBCOOLED HAINSTt(GENANARROMRANGEAVGLEVELSTt(6EN8NARROMRANGEAV6LEVELSTt(GE)tAAVERAGEPRESSURESTttGEN8AVERAGEPRESSURE696&ORONLINEBRENER161372GBGNTORONLINEBRENER9X1372BUS11ASUPPLYBRENERBUS11BSL'PPLYBREAKERNOTTER)(It(ATED Ot(PPCS(7/19/91)

NOTTERHINATED 0)tPPCS(7/19/91)

BUS1lATO12ATIEERENERBUS11BTO128TIEBRENERCONTAIN)(Et(T AVERAGEPRESSURECONMINMEtiT StJ5'AVERAGELEVELSU%'LEVEL8It(CHES(TRAINA)SUtPBLEVEL8It(CPS(TRAINB)SUlF'LEVEL78It<CHES(TRAINA)SU%'LEVEL78INCHES(TRAIN8)SUtI'LEVEL113INCHES(TRAIN A)SUtP8LEVEL113INCHES(TRAIN 8)SU!I'LEVEL180INCHES(TRAIN A)SUtF'LEVEL180INCHES(TRAIN 8)SSP8LEVEL214INCHES(TRAIN A)SUtPBLEVEL214INCHES(TRAIN 8)RCLAHOTLEGTE)(PERATURE RCLBHOTLEGTEt(PERATURE RCLACOLDLEGTEt(PERATNE RCLBCOLDLEGTEt(PERATNE R(uTAVG(THOT/TCOLD MIDERNG)RCLBTAVG(THOT/TCOLD MIDERN6)REACTORVESSELAVERAGELEVELEl.1INCOPETCAVERAGETEttPS/GATOTPAUXFEEDMATER FLOMS/6BTOTALAUXFEEDMATlJt FLOWt(TRAUXILIARY FEEDMATER PU)(PAt(TRAUXILIARY FEEDMATER PU)(PBAUXFMPUtP'STEAt(SUPPLYVALVEAAUXFMPUt'iPSTEA)lSUPPLYVALVE8IVALUEATMSRXTRIPPED8.20350IOI 8.79019401 1.01391-11 1.01391"li

.001076.43.012.3106.9TRIPPEDNOTTRIP59.662.257.11071.622.TRIPPEDTRIPPEDTRIPPEDTRIPPEDNOTTRIPNOTTRIPNOTTRIPNOTTRIP-.212.2LOWERLOWERLOWERLOWERLOWERLOWERLOWERLOWERLOWERLOWER493.5495.5493.8494.0493.7494.799.6495.70.158.OFFONCLOSEDI)ALALRt(ALR)(600D600D6009600DGOODLAL)t600DINH3600DALR)t6009600~HMR)(GOODGOODGOODALRt(ALR)(ALRtfALR)(DELDELALRttALRttGOODGOODGOOD6009600060096XD60006000600))GOODGOOD6000GOODGOODGOODGOODGOOD60006009600DGOODGDOD600DE.U.DE6Fy.y.PSIGPSIGDEGFKGFDEGFlKGFDE6FDEGF)(DEGFPNGPt(p-/2/

XT8s199210:30R.E"GINASINILATOR

'TRENDGROUPASSIMENTSNNARYPAGE2GROUP:EVENT1PROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION VALUEQUALE.U.53FSIA54FSIB55P216056P216157BKR04158BNR04259INR04360INR044SAFETYIN:ECTION:LOOP AAVGFLOWSAFETYINJECTION LOOPBAVGFLOWSERVICEMATERPINPSA&BHEADERSERVICEMATERPNIPSC&DHEADERSERVICEWATERPNPASERVICEMATERPlNPBSERVICEMATERPNIPCSERVICEMATERPNIP00.600DGPtI0.GOODGPN72.600DPSI680.GOODPSI6600DGOODGOODGmEMJ

~~ROGRAMNAHE:LRGTSZ.E R.E.GINNANUCLEARPSJERPLANTOCT08,9210:32:00TRENDGROUPASSIGNHENT SUMMARYGROUPNAHEEVENT2GROUPDESCRIPTIOH PROCEDURE:

EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURRENTVALUEQUALITYCODEEHGRUNITS12345678910111213142021222324252627282930313233343536373839404142430JF0619LRNSTNS033IID033llT033MT250IST2R01R02R05R09R34R35R10AR11R12R10BR13R14R18R19R29R30R15R12ASR'l2A6R12A7R12A9R14A5R14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03TCV07TCVOBTCV09TCV10TCV17COHPONENT COOI.IHGLOOPTOTALFLIIREFUELING

'MATERSTORAGETANKLVL33FOOTLEVELMINDSPEED33FOOTLEVELIJINDDIRECTION 33FOOTLEVELTEMPERATURE 250FOOTLEVELTEMPERATURE 250TO33FOOTLEVELDELTATEMPAREA1-CONTROL ROOMAREA2-CONTAINHENT AREA5-SPENTFUELPITAREA9-LETDOWN LINEMONITORAREA34-AUXBLDGCVSPRAYPUHPAREA35-PASSSAMPLEPANELCONTAINHENT IODINEHONITORR10ACONTAINHENT AIRPARTICULATE CONTAINMENT GASHONITORPLANTVENTIODINEHONITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIQUIDHASTEDISPOSALHONITORSTEAHGENERATOR BLDNDDNNDRAINAREA29-CONTAINHEHT HIGHRANGEAREA30-COHTAINHEHT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LRIRANGEGASCVVENTCHAN6AREAGAMMACVVENTCHAN7-HIDRANGEGASCVVENTCHAN9-HIGHRANGEGASPLANTVENTCNAH5-LmlRANGEGASPLANTVENTCHAN7-HIDRANGEGASPLANTVENTCHAN9-HIGHRANGEGASAIREJECTORCHAN5-LQIRANGEGASAIREJECTORCHAM7-MIDRANGEGASAIREJECTORCHAN9-HIRANGEGASAREA31STEAHLINEA(SPING)AREA32STEAHLINE8(SPING)CVHYDROGENCONCENTRATION CVBASEMENTLVL6FTTEHP¹3CVINTERHEDIATE LVL6FTTEHP¹7CVINTERMEDIATE LVL6FTTEMP¹8CVINTERMEDIATE LVL6FTTEHP¹9CVIHTERHEDIATE LVL6FTTEHP¹10CVOPERATING LVL6FTTEMP¹171485.94'4.880.61.3'3.01.79.02214-02 7.35678+00 1.39946+00 1.43501+02 9.09354-01 1.09283+00 9.58719+01 5.18901+02 738002+024.30543+01 8.58327+01 4.22831+01 2.78658+03 1.47174+04 5.05861.01 5.09440-01 1.57835+03 1.89699.07 2.53990.02 3.57435-05 1.41261-03 4.40312.07 6.86543.05 3.72621-03 2.09411-07 1.34492-05 1.27941-03 2.85040+00 1.01048.02

.095.1106.0106.6106.7106.2117.5GOODGOODGOMGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODG(XX)GOODGOODGOODGOODHALHGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODNALMGOODGOODGOODGOODGOODGOODGOODGOODGPHXMPHDEG.DEGFDEGFDEGFMR/HHR/HMR/HHR/HMR/HMR/HCPMCPHCPHCPMCPHCPMCPHCPHR/HRR/HRCPMUCI/CCHR/NRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRMR/HRXDEGFDEGFDEGFDEGFDEGFDEGF Time:~~4Message:~4INNATATIN12EVALATEDEXERElVIESAEFORM~MI:MI<<CIRSimulaedPlanCondiions:SeetheAttachedSheets~Massee:"""THISISANEXERCISE"""

FORCONTROLLER USEONLY~CIR1)Accidentresponseandevaluation continue.

2)Ifnotdoneearlier,theAuxiliary Operatorsentouttoisolatethe"B"S/GARVsteamleak,reportstoControlRoom/TSCthatitisisolated.

AnticiaedResuls:1)Operators performing theactionsofE-3/Steam Generator TubeRuptures) shouldhavestabilized thePlantatapproximately thistimeandbeawaitingdetermination bytheTSCastowhatpostSGTRCooldownprocedure touse.2)Ifnotdoneearlier,ControlRoomshouldinformtheTSCofthe"B"S/6ARVsteamleakisolation.

3)TheTSCshouldbeevaluating theflammable gasproblemintheScreenhouse andbetakingcorrective actionsrequiredtoreturntheScreenhouse toasafecondition.

's(continued onthenextpage) 4)TheTSCDoseAssessment shouldbecalculating andquantifying anyreleasepathstotheenvironment.

5)TSCshouldhavedetermined andinformedtheControlRoomtouseES-3.1(Post-SGTR CooldownUsingBackfill).

6)RepairTeamsentouttocheckthe"B"S/GARVsteamleakshouldhavereportedbackthatitappearsthatthesteamleakwasfromaholedrilledalmostthroughthepipe.Theyreportthatitwilltakeapproximately oneandone-halfhourstorepairtheleak.

199EVALUATED EXERCISETime:/0'/bMAZORPAEUQIETERS ENGINEERED SAFEGUARDS ReactorShutdownESNON-31~CPSN-32CPSN-35I.oa-IAMFSN-36~/AMPSAvg.NuclearPowerRCSPressureO7PSIGPRZRLevelARCPRUNNINGTOPPEBRCPUNNISTOPPED1AS/GLevel~ls&1BS/GLevelAVElAS/GPressure4PSZG1BS/GPressureR~PSIGTurbine/Generator ONLINE/F4KVBusesNERGIZDEENERGIZED 480VBusesNERGIZDEENERGIZED DCBatteries A~loVOLTSBISOVOLTSCnmtPressure~~2a.PSTGCnmtSumpALevel243FEETCnmtSumpBLevelINCHESALoop.HotLegOFALoopColdLegf73POFBLoopHotLeg8.K0FBLoopColdLeg97.o0FRVLIS%&*CET~9.7OFS/GATotalAuxFWFlowOGPM5/GBTotalAuxFWFlow~SGPMDIESELGENERATORS A.RUNNINGUNLOADEDTBOOSB.RUNNINGUNLOADEDTBOOSTSCRUNNINGUNLOADEDTBOOSSecurityRUNNINGUNLOADEDTBOOSENGINEERED SAFEGUARDS Aux.Feedwater Pums1A.INSERVBOOS1B.NSESTBYOOSTurb.DrivenINSERVTBOOSCSTLevel~FEETHihHeadS.I.PumsF1-924~GPMFl-925~GPM1AINSERVTBOOS1B.INSERVBOOS1C.INSERVTBOOSBASTLevel=/OLowHeadS.I.PumsFI-626OGPM1A.INSERVTBOOSRECIRC1B.INSERVTBOOSRECIRCRWSTLevel=S.Containment SraPumsFI-931AC7GPMFI-931B~GP 1A.INSERVTOOS1B.INSERVTBOOSNaOHTankLevel=Containment RecircFans1A.SERVSTBYOOS1B.NSESTBYOOS1C.RSTBYOOS1D.INSERVSTBYOOSPostAcesentDampersOPECLOSEDServiceWaterPums1A.INSERVSTBYOS1B.SSTBYOOS1C.SESTBYOOS1D.NSERSTBYOOSA&BHeaderPressure~70PSTGComonentCoolinWaterPums1A.INSERVSTBYOS1B.NSEVSTBYOOSSurgeTauvel=~5StandbAux.FewaterPums1C.INSERVTBOOS1D.INSERVTBOOS*CET=AverageofSelectedCoreExitThermocouples

,8~199210'44R.E.GMASINULATOR

-TRENDGROUPASSIBNNENT SUNNARYPA6E16ROUP:EVENT}PROCEDURE}

EPIP1-5PLANTSTATUS123'567810ii1213141516171819202122232425262728293031323334353637383940414243444546474849505152POINT'DATMSRXTN31N32N35N36NPPRCSLP2RFR%AFRCLBRXT}6RXT}7TSUBTCLSBALSBBPSBAPSBBGENBKR}GENBKR2'BUSABUS}1BBUS12ABUS}2BB}1A}2ABi}B12BPCVLS(@PAL0942iL0943EL0942DL0943DL0942CLO943CL0942BL09439L0942AL0943AT0409AT0410AT0450T0451TAVGAMIDTAVGBMIDLRVTCCOREFAUXFWAFAUXFMBBKR081BKR082V3505V3504DESCRIPTION ANTICIPATED TRANSIENT M/0SCRANREACTORTRIPBREAKERSTATUSSO(jKERANGEDETECTORN-31SMCERANGEDETECTORN-32INTERNEDIATE RANGEDETECTORN-35INTEI(NEDIATE RANGEDETECTORN-36AVERAGENUCLEARPOWERREACTORCOOLANTSYSTENAVGPRESSPRESSURI2ER AVERAGELEVELREACTORCOOLANTLOOPAAVGFLOWREACTORCOOLANTLOOPBAVGFLOWRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCORETCSUBCOOLED NARBINSTNGENANARROMRANGEAVGLEVELSTNGENBNARROMRANGEAVGLEVELSTNGENAAVERAGEPRESSURESTNBENBAVERAGEPRESSUREGENERATOR ONLINEBREAKFR161372GsSRATORONLINEBREAKER9X1372BUS11ASUPPLYBREAKERBUS11BSUPPLYBREAKERNOTTERNINATED ONPPCS(7/19/91) NOTTERNlhATED OttPPCS(7/19/91) BUSilATQ12ATIEBRENERBUS1}BTO128TIEBREAKERCONTAINNENT AVERAGEPRESSURECONTAINNENT SUNPAAVERAGELEVELSU)4'LEVEL8INCHES(TRAINA)~SU%'LEVEL8INCHES(TRAIN9)SSPBLEVEL78INCHES(TRAINA)SUtPBLEVEL78INQSS(TRAINB)SUtPBLEVEL113INCHES(TRAIN A)SUN'LEVEL113INCHES(TRAIN B)SU%'LEItcL180INCHES(TRAIN A)SUtPBLEVEL}80INCHES(TRAIN B)SUt}BLEVEL214INCHES(TRAlt< A)SUtPBLEVEL214INCHES(TRAIN B)RCL/)HOTLEGTENPERATUFE RCLBHOTLEGTENPERATURE RCLACOLDLEGTE)IPERATNE 'RCLBCOLDLEGTE)IPERATNE RCLATAVG(THQT/TCOLD WIDERNB)RCLBTAVB(THOT/TCOLD WIDERNB)REACTORVESSELAVERAGELEVELEl.lINCORETCAVERAGETENPS/6ATOTALAUXFEEDMATER FLOWS/GBTOTALAUXFEEDMATER FLOWNTRAUXILIARY FEEDMATER PU)(PANTRAUXILIARY FEEDMATER PUNPBAUXFMPUt(PSTEANSUPPLYVALVEAAUXFMPUt(PSTEA)ISUPPLYVALVEBATMSALRfiRXTRIPPEDALR)(8.6397}%} 60098.8206M)i 60091.01391-11 60091.01391-11 6009.0060091071.LAL)(43.4600912.3INHB106.96009TRIPPEDALRNNOTTRIP600959,0600t6}.5HMRt(64.3HMR)(1065.6009622.GOODTRIPPEDALRt(TRIPPEDALRt(TRIPPEDALRt(TRIPPEDALRt(NOTTRIPDELNOTTRIPDELN)TTRIPALRNNOTTRIPALRt(-.21GOOD2.3HMRt(LONERGOODLOltER6009LOWER6009LOWER6009LOWER6009LOWER6009LONER6009LOWERGOODLOWER6009LOWER6009493.5600D495.56009493.86009494.06009493.7G009494.7600999.66009495.7600~0.6009158.6009OFFGOODONGOODCLOSED6009CLOSEDGOODF-12'.U.CPSCPSANPXPSIBXXXDEGFXXPSIGPSIGDEBFKGFDEGFDEGFDEBFDEBF/DE6FPNGPN

OCTHs199210:44R.E.6INASINLATOR'REND6ROUPASSISINENT SUSARYPASE26ROUP:EVBIT1PRXEDURE'PIP 1-5PLANTSTATUSPOINTIODESCRIPTION VALUENNLE.U.53FSIA54FSIB55P216056P216157INR04158BIIR04259BKR04360BIIR044SAFETYINJECTION LOOPAAV6FLOWSAFETYINJECTION LOOPBAV6FLOMSERVICEMATERPNIPSAhBHEADERSERVICEMATERPNIPSC50HEADERSERVICEMATERPNIPASEINICEWATERPNIPBSEINICEWATERPINPCSEINICEWATERPUIIPD0.0.72.80.600D6Pll600D6PII600DPSI66000PSI6600D600D600D600D ~~~OGRAMHAME:LRGTSZ.E .E.GINNANUCLEARPONERPLANTOCT08,9210:49:00TRENDGROUPASSIGNHENT SUMMARYGROUPNAHEEVEHT2GROUPDESCRIPTION PROCEDURE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTIOH CURRENTVALUEQUALITYCODEENGRUNITS234567891012131420212224252627282930313233343536373839404142430-F0619LRIISTWS033M)033MT033WT250IST2R01R02R05R09R34R35R10AR11R'12R10BR'13R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14A5R14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03TCV07TCVOBTCV09TCV10TCV17COMPONENT COOLINGLOOPTOTALFLllREFUELIHG IIATERSTORAGETANKLVL33FOOTLEVELHINDSPEED33FOOTLEVELMINDDIRECTION 33FOOTLEVELTEMPERATURE 250FOOTLEVELTEMPERATURE 250TO33FOOTLEVELDELTATEHPAREA1-CONTROL ROOMAREA2-CONTAIHHEHT AREA5.SPENTFUELPITAREA9-LETDONN LIHEMONITORAREA34-AUXBLDGCVSPRAYPUMPAREA35-PASSSAMPLEPANELCONTAINMENT IODINEHONITORR10ACONTAINMEHT AIRPARTICULATE CONTAINMENT GASHONITORPLANTVEHTIODINEMONITORR108AUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIQUIDIIASTEDISPOSALMOHITORSTEAMGEHERATOR BLONDONNDRAINAREA29-CONTAINMENT HIGHRANGEAREA30CONTAINMENT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVEHTCHAN5-LDNRANGEGASCVVENTCHAN6-AREAGAHHACVVENTCHAH7-MIDRANGEGASCVVENTCHAH9-HIGHRANGEGASPLANTVENTCHAN5-LOLIRANGEGASPLANTVENTCHAN7HIDRANGEGASPLANTVENTCNAH9-HIGHRANGEGASAIREJECTORCHAM5-LOW'RANGE GASAIREJECTORCHAN7-HIDRANGEGASAIREJECTORCHAN9-HlRAHGEGASAREA31STEAMLINEA(SPING)AREA32STEAMLINEB(SPING)CVHYDROGENCOHCEHTRATIOH CVBASEMEHTLVL6FTTEMP¹3CVINTERMEDIATE LVL6FTTEHP¹7CVINTERMEDIATE LVL6FTTEMP¹8CVINTERMEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEMP¹10CVOPERATING LVL6FTTEHP¹171485.94.55.279.61.463.52.19.02214-02 7.35678i00 1.3994&00 1.41701+02 9.09354-01 1.09283+00 9.58715401 5.18901+02 7.38002+02 4.30543i01 8.58327+01 4.22831+01 2.78658t03 1.42174i04 5.05861-01 5.09440.01 1.57835+03 1.89699.07 2.53990-02 3.57435-05 1.41261-03 4.40312-07 6.86543-05 3.72621-03 2.09411.07 1.34492-05 1.27941-03 2.72040t00 1.01048-02 .095.1106.0106.6106.7106.2117.5GOODGOODGOODGOODGOODGOODGOODGO(eGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALHGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALHGOODGOODGOODGOODGOODGOODGOODGOODGPH)IMPHDEG.DEGFDEGFDEGFMR/HHR/HMR/HMR/HMR/HMR/HCPMCPHCPMCPHCPMCPMCPMCPHR/HRR/HRCPHUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/NRMR/HRXDEGFDEGFDEGFDEGFDEGFDEGF Time:~1~4IVlessage: ~l~NATATI~2EVLATEDEERIEMEAEFRM~f:RRN<<IGRINGRIITTSimulated PlanConditions: SeetheAttachedIVlini-Scenario ~Messee:"""THISISANEXERCISE""" FORCONTROLLER USEONLYGGGI1)Provideinformation verballywhenappropriate investigations andactionsaremadebytheScreenhouse NaturalGasRemovalFireandSafetyTeam.AniciatedResults:1)AsperMini-Scenario Anticipated Results. ~GINNNNTTlN1992EVALUATED EXERCISEMINI-SCENARIO ~ActitrlScreenhouse NaturalGasRemovalFORCONTROLLER USEONLYController Notes:1iifFireandSafetyTeamchecksgasconcentration, ~infrmthemthatthegasconcentration isnotwithintheflammable rangeofthecombustible gasindicator used.AnticiatedResuls:1)FireandSafetyTeamshouldevaluatewinddirection todetermine bestutilization fornaturalventilation andpreparehoselinesforfiresuppression activities. 2)FireandSafetyTeamshould~imalaestablishing naturalventilation viabreakinggradelevelScreenHousewindowsonSouthsidefirstandbreakingglasswindowsinNorthwest section.Masterstreamfoglinesshouldbeactivated ontheSouthsideintheareaofthebrokenwindowstoenhanceairmovementandpromoterapidventilation ofthearea.g-(3o Time:~1)~4Message:~QX~NNATATiN12EVALATEDEXERIEMEAEFRM~Mf:TggggTggiSimlaedPlanConditions; Messac~:<<""THISISANEXERCISE"">> DeclareaSITEAREAEMERGENCY inaccordance withEPIP1-0,"GinnaStationEventEvaluation andClassification," EAL:HazardsBeingExperienced orProjected; EntryofUncontrolled Flammable GasesintoVitalAreas.FORCONTROLLER USEONLYController Notes:1)DeliveronlyifITEAREAEMERGENCY hasnotbeendeclared. DnodliverifEmerencClssificaiondiscusionsareinroress.AnticiatedResuls:1)Delivercontingency messageifSITEAREAEMERGENCY isnotdeclaredorisnotbeingdiscussed. Time:11QQMessage:~7GINNASTATION1992EVALUATED EXERCISEMESSAGEFORMEiI<<C<<IRSimulated PlantConditions: SeetheAttachedSheetsMessa<ee: """THISISANEXERCISE""" TheCondensate StorageTanksareatfive(5)feet.FORCONTROLLER USEONLYController Notes:AniciaedResIs:1)Operators shouldrefertoER-AFW.1(Alternate WaterSupplytoAFWPumps)perfoldoutpageofES-3.1,Statement 4,whichstates,"IfCSTleveldecreases to,lessthanfive(5)feet,thenswitchtoalternate AFWsupply(refertoER-AFW.1, Alternate WaterSupplytoAFWPumps)"andperformapplicable actions.2)ControlRoomshouldinformTSC.oflowlevelintheCSTs.3)CohtrolRoomshouldbeperforming theapplicable actionsofES-3,1(post-SGTR CooldownUsingBackfill). 4)TSCshouldbeevaluating Plantconditions andtakingactionwhererequired, 5)TSCshouldinformsecurityoftheasfoundconditions ofthe"B"S/GARVsteamleak.(continued onnextpage) 6)TSCDoseAssessment performing offsitedosecalculations asrequired. 7)TSCshouldbeexpediting therepairoftheS/GARVsbecauseoftheiruseduringsucheventsaslossofcondenser andPlantcooldown. 8)TSCshouldsendarepairteamtocheckoutthe"A"SWPumpproblemwhenScreenhouse isdeclaredsafeforentry.9)TSCshouldinformEOFofPlantstatusandproblems. 10)Securityshouldbeevaluating thedrilledholeinthe"B"S/GARVpipe.11)TheEOF,afteritismanned,shouldstartassessing Plantconditions andtakeactionasrequired. 199P'VALUATED EXERCISETime:~/DOMAJORPAE%METERS ENGINEERED SAFEGUARDS A.RUNNINGUNLOADEDTYOOSB.RUNNINGUNLOADEDBOOSTSCRUNNINGUNLOADEDOOSSecurityRUNNINGUNLOADEDTENGINEERED.SAFEGUARDS OOSReactorShutdownYESNON-31CPSN-32~~CPSN-35~=-//AMPSN-36IMPSAvg.NuclearPower0RCSPressureoÃeipsIGPRZRLevel93~ARCPRNG/TOPPEDBRCPUNNINSTOPPEDlAS/GLevel~'L41BS/GLevel1AS/GPressure~o~PSIG1BS/GPressure85PSIGTurbine/Generator NLINEFFLI4KVBusesNERGIZEDDEENERGIZED 480VBusesERGIZEDEENERGIZED DCBatteries AfSoVOLTSB/SoVOLTSCnmtPressure-emIPSIGCnmtSumpALevelZ.3FEETCnmtSumpBLevelINCHESALoopHotLeg9d.OFALoopColdLegOFBLoopHotLegl~n.2OFBLoopColdLeg~gZ-OFRVLISc~7*CET9JL'5~~OF '/GATotalAuxFWFlowoGPMS/GBTotalAuxFWFlowV2GPMDIESELGENERATORS HihHeadS.I.PumsFI-924COGPMFI-925~GPM1AINSERVOOS1B.INSERVBOOS1C.INSERVTBOOSBASTLevel=~gLowHeadS.I.PumsFI-626NGPM1A.INSERVOOSRECIRC1B~INSERVTBOOSRECIRCRWSTLevel=Containment SraPumsFI-931AGPMFI-93IB~GPM1A.INSERVTBOOS1B.INSERVTBOOSNaOHTankLevel=Containment RecircFans1ASESTBYOOS1B.INSESTBYOOS1C.RSTBYOOS1D.INSERSTBYOOSPostAcesentDampersPENCLOSEDServiceWaterPums1A.INSSTBY01B.SESTBYOOS1C.SESTBYOOS1D.SESTBYOOSA&BHeaderPressure~V~PSIGComonentCoolinWaterPums1A.INSVSTBY001B.NSERVSTBYOOSSurgeTanLevel=~/Aux.Feedwater Pums1A.INSRVTBOOS1B.NSERSTBYOOSTurb.DrivenINSERVSTBOOSCSTLevelFEET*CET=AverageofSelectedCoreStandbAux.FeaterPums1C.INSERVTOOS1D.INSERVTBOOSExitThermocouples OCTGi1992II:(OR.E.BIWASltaLATOR TREND6ROUPAKIGtmENT SUt(NARYPAGE16ROUP:EVENT1PROCEDURES EPIP1-5PLANTSTATUSPOINTID1ATNS2RXT3N314N325N356N367NP8PRK9LPIR10FRCLA11FRCLB12R)(T1613RXT1714TSUBTC15LSGA16LSGB!7PSGA18PSGB19GENBKRI20GENBKR221BUS11A22BUS11B23BUS12A24BUS12B25BIIA12A26B11012927PCV28LS(NPA29L0942E30L0943E31L0942932L0943D33L0942C34L0943C35L0942036L0943B37L0942A38L0943A39T0409A40T0410A41T045042T045143TAVBAWID44TAVBBWID45LRV46TCCORE47FAUXFWA48FAUXFWB49BKFQBI50BKR08251V350552V3504DESCRIPTION ANTICIPATED TRANSIENT N/0SCRA)(REACTORTRIPBREAKERSTATUSSMICERANGEDETECTORN-31So(SCERA%EDETECTORN-32INTERMEDIATE RANGEDETECTORN"35INIERt(EDNTE RANGEDETECTOR,N-36 AVERAGENLGSARPOWERREACTORCOOLANTSYSTEt(AVGPRESSPRESSURIIER AVERAGELEVELREACTORCOOLANTLOOPAAVGFLOWREACTORCOOLANTLOOPBAVGFLOWRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCORETCSUKOOLEDtmRBINSTNGEN.ANARRONRAhBEAVGLEVELSTtlGENBNARROWRANGEAVGLEVELSTNGENAAVERAGEPRESSURESTttGEttBAVERAGEPRESSUREGBGQTORONLINEBREAKER161372GENERATOR ONLINEBREAKER9X1372BUS11ASUPPLYBREAKERBUS11BSUPPLYBREAKERNOTTERHlt(ATED ONPPCS(7/19/91) t<OTTERHINATED ONPPCS(7/19/91) BUS11ATO12AT[EBREWERBUS11BTO12BTIEBREAKERCONTAIOENT AVERAGEPRESURECONTAIN)(ENT SUt(PAAVERAGELEVELSUtPBLEVEL8INCHES(TRAINA)SUtPBLEVEL8INCHES(TRAIN0)SUtPBLEVEL78INCHES(TRAINA)SUtPBLEVEL78INCHES(TRAINB)SUtPBLEAL113INCHES(TRAIN A)SUtPBLEVEL113INCHES(TRAIN B)SUIPBLEVEL180INCHES(TRAIN A)SUtPBLEVEL180INCHES(TRAIN B)SUtPBLEVEL214It(CHES(TRAIN A)SUNUPBLEVEL214INCHES(TRAIN B)BC'OTLEGTEt(PERATLK RRBHOTLEGTEIIPERATUlt= RCLACOLDLEGTEtFERATNE RCLBCOLDLEBTEtPERATNE RCLATAVG(TKIT/TCOLD WIDERNB)RCLBTAVG(TtK)T/TCOLD WIDERNB)REACTORVESSELAVERAGELEVELEl.1INCORETCAVERAGETEt(PS/GATOTALAUXFEEDMATER FLOMS/GBTOTAl.AUXFEEDMATER FLOWt(TRAUXILIARY FEEDMATER PUt(PAtITRAU)(ILIARY FEEDNATER PIWP0AU)(FWPUI(PSTEANSIFPLYVALVEAAUXFMPULE'TEA)I SL4'PLYVALVEBATWSALRI(RXTRIPPEDALRII8.46249+01 600D8.28893+01 600D1.01391-11 60001.01391-11 GOOD.0060001056.LALII43.1600D12.3INHH107.5GOODTRIPPEDALRI(NOTTRIPGoon63.1Gooe59.6HNRN50.560001053.6009585.LNRt(TRIPPEDALRI(TRIPPEDALRI(TRIPPEDALR(NOTTRIPDELNOTTRIPDELNOTTRIPALRI(NOTTRIPALRI(-.2160002.3HWRt(LOWERGOODLONERBoonLOWER6000LOWER6000LOWER6000LONER6000LOWER6000LOWER6000LOWER6000LOWER6000490.4600D490.26009488.46000488.26000489.46000489.2GOOD99.76000489.9Boot0.600972.6000OFFGOODON6600cLOBED.BoonCLOSED6000pE.U,CPSCPSNPAt(PXPSIGXXKGFX'XPSIGPSIGDE6FKGFDEGFDEGFKGFDEGFXDEBFGPtlGPtl OCTGi199211:00R.E.GINASINKATORTREND6ROUPASSIGNEttT RNtNRYPAGE2GROUP:EVENT1PRXEDURE'PIP 1-5PLAttTSTATUSPOINTID'DESCRIPTION VALUEQUALE.U.53FSIA54FGIB55P216056P216157BKR04158BKR04259BKR04360BKR044SAFETYINJECTION'LOOP AAVGFLOWSAFETYINJECTION LOOPBAVGFLOWSERVICEWATERPUtrPSAhBHEADERSERVICEMATERPNPSC5DHEADERSERVICEWATERPUtIPASERVICEWATERPNPBSERVICEWATERPNPCSERVICEWATERPINPD0.600DPN0.GOOD6PN72.600DPSI680.GOODPSI6GOODGOODGOODGOOD ~~~OGRAMNAME:LRGTSZ.E R.E.GINNANUCLEARPOUERPLANTOCT08,9211:01:00TREHDGROUPASSIGNHENT SUMMARYGROUPNAMEEVENT2GROUPDESCRIPTIOH PROCEDURE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURRENTVALUEDUALITYCODEENGRUNITS1234567891011121314202122232425262728293031323334353637383940414243-~F0619LR'IISTWS033IJD033IIT033MT250NDT2R01R02R05R09R34R35R10AR11R12R10BR'13R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14A5R14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03.TCV07TCV08TCV09TCV10TCV17COMPONENT COOLINGLOOPTOTALFLIIREFUELIMG IIATERSTORAGETANKLVL33FOOTLEVELIIINDSPEED33FOOTLEVELMINDDIRECTION 33FOOTLEVELTEHPERATURE 250FOOTLEVELTEMPERATURE 250TO33FOOTLEVELDELTATEMPAREA1-CONTROL ROOHAREA2-CONTAINMEHT AREA5-SPENTFUELPITAREA9-LETDONM LINEMONITORAREA34AUXBLDGCVSPRAYPUMPAREA35-PASSSAMPLEPANELCONTAINMEHT IODINEHOHITORR10ACONTAINMENT AIRPARTICULATE COHTAIHHEHT GASMONITORPLANTVEHTIOOIHEMONITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIQUIDIIASTEDISPOSALHONITORSTEAMGEHERATOR BLOMDONNDRAIHAREA29-CONTAINHENT HIGHRANGEAREA30-CONTAINMENT HIGHRANGECOHDEHSER AIREJECTOREXHAUSTCVVENTCHAM5-LOIIRANGEGASCVVENTCHAH6-AREAGAMMACVVENTCHAN7-MIDRANGEGASCVVENTCHAN9-HIGHRANGEGASPLANTVENTCHAN5-LOMRAMGEGASPLANTVEHTCHAN7.MIDRANGEGASPLANTVEHTCHAN9HIGHRANGEGASAIREJECTORCHAN5LOURANGEGASAIREJECTORCHAN7-HIDRANGEGASAIREJECTORCHAN9HlRANGEGASAREA31STEAMLINEA(SPING)AREA32STEAHLINEB(SPIKG)CVHYDROGEHCONCENTRATION CVBASEMENTLVL6FTTEMP¹3CVINTERMEDIATE LVL6FTTEMP¹7CVINTERMEDIATE LVL6FTTEHP¹8CVINTERMEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEMP¹10CVOPERATING LVL6FTTEMP¹171485.94.54.879.62.464.92.59.02214-02 7.35678+00 1.3994&00 1.38701+02 9.09354-01 1.09283+00 9.58719101 5.18901+02 7.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658+03 1.38174+04 5.05861-01 5.09440.0'I 1.57835+03 1.89699-07 2.53990-02 3.57435-05 1.41261.03 4'0312.076.865C3-05 3.72621-03 2.09411-07 1.34492-05 1.27941-03 2.680CO+00 1.01048-02 .095.1106.0106.6106.7106.2117.5GOODGOODGOODGOODGOODGOODGOOD6000GOOD60006000GOODGOODGOODGOODGOODGOODGOODGOOD6000HALHGOODGOODGOOD6000GOODGOODGOODGOODGOODGOODGOOD6000GOODBALMGOODGOODGOODGOODGOODGOOD6(XNGOODGPHXMPHDEG.DEGFDEGFDEGFHR/HMR/HMR/HMR/HMR/HMR/HCPHCPMCPMCPMCPHCPMCPMCPMR/NRR/HRCPMUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRMR/HRXDEGFDEGFDEGFDEGFDEGFDEGF Time:11QQMessage:~QINNATATN12EVALATEDEXEREIVIESAEFRIVI~WP:PARWPpTfpPPfRpfTSimulaedPlnConditions: SeetheAttachedMini-Scenario ~Mes~e:"""THISISANEXERCISE""" FORCONTROLLER USEONLYController Notes:1)Provideinformation verballywhenappropriate investigations andactionsaremadebythe1ASWPumpTripProblemRepairTeam.AnticiatedResults:1)AsperMini-Scenario Anticipated results. NINNIINTIITINN2EVALUATED EXERIEMINI-SENARITITLE'ArviWrPmBrkrTriExpectedscenariostarttime:1015INITIALCONDITIONS: PumprunningMETHODOFINITIATION: Breakertrips,Operations callsforElectricians toinvestigate. INDICATIONS'ONTROL ROOM:~AiarmWindow:"J-9"Safeguard BreakerTrip~Whiteidiaagreementi light:SWP1ABUS18/POS29C:~Amptector: Noindication ofAmptector ~Alarmswitchcontactsnotactivated SWP1AMOTOR:~Noindication oftroubleLOCALCTRLSTA.:~Noindication oftroubleoMCBControlSwitchto"Trip"clearswhitelightandAlarm.oAttemptstoclosebreakerfromControlRoomdonotsucceed;indications asabove.oWhenLocalControlPanelTransferSwitchisturnedto"Local,"breakercanbeclosedelectrically. Transferto"Remote"(MCB)TripsBreakerwithaboveindications again.EXPECTEDSEQUENCEOFACTIONS:oInvestigate Screenhouse forvisiblesignsnearbreakerormotor.~Noindications noticedoObtainholds,clearances, andtestequipment. oSimulatemeasuring resistance phasetophase5meggermotorfromBus18/Pos29Creadings: Megger,readings: )100MQtogroundPhasetophaseresistance: good(continue onnextpage) oTakeLocal/Remote SwitchtoLocalandclosebreaker.oTestandconfirmshortedRedLight.FINALCONDITIONS: ServiceWaterPumpoperatedfromLocalControlPanel.LocateshortedRedLightinMainControlBoard,andreplace,ReturnBreakertoservice. Time:11QQMessage:~9INNATATIN2EVALATEDEXEREMESAGEFRM~Mf:Slfllplfd'S'Sfdldddlp PlltddlTSimulaedPlanCondiions:SeetheAttachedMini-Scenario ~Messae:"""THISISANEXERCISE""" FORCONTROLLER USEONLYController Notes:1)Provideinformation verballywhenappropriate investigations aremadebytheSecurityInvestigation Teaminvestigating the"B"S/GARVPipeDrilledHole.AnticiatedResults:1)AsperMini-Scenario Anticipated Results. INNASTATIN12EVALUATED EXERCISENIINI-SCENARIO ~A1~IVIg:SecurityInvestigation ofthe"B"S/GARVPipeDrilledHoleFRCONTROLLER USEONLYN1)Securityshouldfollowtheirnormalprocedures forapparenttampering withequipment. 2)SeeattachedsketchonSteamLeak.AniciaedResuls:1)SecurityshouldcheckthedoorentriestoSteamHeaderareaforaselectedtimeblock.2)Basedupontheentriesintothearea,aprofileshouldbeperformed onselectedindividuals. 3)Baseduponresultsoftheaboveprofiles, securitymay~im~laainterrogation ofselectedindividuals. 4)InformTSCandEOFofanyfindingsfromabove. GINNASTATION:ROCHKSTKI GASANDKLECTltCCOIttOltATION DATE:mrnasPAGEOFsOB:Sks'rcpto'>gAtV$78~~LEALMADEBY: Time:~111Message:~4~INNATATI~12EVALUATED EXERIEMEAEFRMI:RI<<RIRimlaePlnndiIn:SeetheAttachedSheets~Messee:"""THISISANEXERCISE""" FORCONTROLLER USEONLY1)DlTruckstartspumpingtooutsidestoragetank.AnticiatedResuls:1)Operators performing theApplicable ActionsofES-3.1(Post-SGTR CooldownUsingBackfill). 2)Operators performing theApplicable ActionsofER-AFW.1(Alternate WaterSupplytotheAFWPumps). 199PEVALUATED EXERCISETlate:///5MAZORPAEKMETERS ENGINEERED SAFEGUARDS A.RUNNINGUNLOADEDOOSB.RUNNINGUNLOADEDSTBOOSTSCRUNNINGUNLOADEDTBOOSSecurityRUNNINGUNLOADEDSTBENGINEERED SAFEGUARDS OOSReactorShutdownENON-313CPSN-32~~CPSN-35t,~IIAMPSN-36g,@~AMPSAvg.NuclearPowerRCSPressure025PSIGPRZRLevelARCPRTOPPEBRCPUNNNSTOPPED1AS/GLevel1BS/GLevel.IlAS/GPressurePSIG1BS/GPressurePSIGTurbine/Generator ONLINEFLNE4KVBusesNERGIZEDEENERGIZED 480VBusesNERGIZEDEENERGIZED DCBatteries A~OVOLTSB/SoVOLTSCnmtPressure-~2.PSIGCnmtSumpALevelFEETCnmtSumpBLevelINCHESALoop'HotLeg7z.OFALoopColdLegQadi~OFBLoopHotLeg7~OFBLoopColdLegOFRVLIS*CETeOFS/GATotalAuxFWFlowOGPMS/GBTotalAuxFHFlow~&GPMDIESELGENERATORS HihHeadS.I.PumsFI-924OGPMFI-925&GPM1A.INSERVTOOS1B.INSERVTBOOS1C.INSERVTBOOSBASTLevel=0LowHeadS.I.PumsFI-626GPM1AINSERVBOOSRECIRC1B.INSERVBOOSRECIRCRWSTLevel=3.Containment SraPumsFI-931A0GPMFi-931B~GPM 1A.INSERVBOOS1B.INSERVTBOOSNaOHTankLevel=Containment RecircFans1A.NSESTBYOOS1B.NSERSTBYOOS1C.NSESTBYOOS1D.NSESTBYOOSPostAccidentDampersPECLOSEDServiceWaterPums1A.INSERVSTBY01B.NSESTBYOOS1C.ERSTBYOOS1D.SERVSTBYOOSA&BHeaderPressure~0PSXGComonentCoolinWaterPums1A.INSERSTBY1B.NSERSTBYOOSSurgeTankLevel~7Aux.Feedwater Pums1A.INSERVTBOOS1B.NSRSTBYOOSTurb.DrivenINSERVBOOSaCSTLevelFEET*CET=AverageofSelectedCoreStandbAux.Feedwater Pums1C.INSERVTBOOS1D.INSERVTBOOSExitThermocouples F-~W 8s199211:15R.E.GINASIMULATOR TRB(DGROUPASSIGHMEHT SUMMARYPA6E1GROUP:EVENT1PROCEDURE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION E.U.123567891011131415161718192021222324252627282930313233343536.373839404142434445464748495051AT%RXTN31N32N35H36t(PPRCSLPIRFRCLAFRCLBRXT16RXTijTSUBTCLSGALSGBPSGAPSGBGEHBKR!GENBKR2BUS11ABUS11BBUS12ABUS12BB11A12ABllB12BPCVLSWPAL0942EL0943EL0942DL09439L0942CL0943CL0942BL0943BL0942AL0943AT0409AT0410AT0450T0451TAVGAMIDTAKBWIDLRVTCCOREFAUXFMAFAUXFMBBKR081BKR082V3505<<V3504ANTICIPATED TRANSIENT M/0SCRAMREACTORTRIPBRENERSTATUSSMKERANGEDETECTORH-31SONCERA%EDETECTORN-32INIEfIEDIATE RANGEDETECTORN-35INTERMEDIATE RANGEDETECTORN-36AVERAGENUCLEARPOWERREACTORCOOLANTSYSTEMAVGPRESSPRESSURIIER AVERAGELEVB.REACTORCOOLANTLOOPAAVGFLOWREACTORCOOLANT1.00PBAVGFLOWRCPABREAKERCAUSERXTRIPRCPBBRENERCAUSERXTRIPINCORETCSUBCOOLED MARGINSTMGEHANARROWRANGEAVGLEVELSTMGB(BNARROWRANGEAVGLEVELSTMGEHAAVERAGEPRESSURESTM6EttBAVERAGEPRESSUREGEtGMTOR. ONLINEBREAKER1G1372GsJRRATOR ONLINEBREAKER9X1372BUS11ASUPPLYBRENERBUSllBSUPPLYBRENERHOTTERMINATED OHPPCS(7/19/91) NOTTERMINATED OHPPCS(7/19/91) BUS11ATG12ATIEBRENERBUS11BTG12BTIEBRENERCONTAINMEHT AVERAGEPRESSURECGNTAIHMEt(T SUMPAAVERAGELEVELSSPBLEVEL8INCHES(TRAINA)SUtPBLEVEL8INCHES(TRAIN9)SUtF'LEVEL78ItKHES(TRAINA)SUtPBLEVEL78IHC)'.cS(TRAINB)SUtPBLEVFL113INCHES(TRAIN A)SUN'LEVEL113INCHES(TRAIN B)SUtPBLE(tcL180INCHES(TRAIN A)SUtPBLEVEL180INCHES(TRAIN B)SU%'LEVcL214INCHES(TRAIN A)SUPBLEVEL214INCHES(TRAIN B)RCLAHOTLEGTEMPERATURE RCLBHOTLEGTEMPERATURE RCLACOLDLEGTE)(PERATIEE RCLBCOLDLEGTE)(PERATNE RCLATAVG(THDT/TCOLD WIDERNG)RCLBTAVG(T)OT/TCOLD WIDERNG)REACTORVESSELAVERAGELEVELEl.1INCORETCAVERAGETEMPS/GA:OTALAUXFEEI'4(ATcD FLOWS/6BTOTALAUXFEECSNWFLOWMTRAUXILIARY FEEINATER PUlPA'TRAUXILIARY FEEOMATER PUt(PBAUXFMPUttSTEAtlSUPPLYVALVEAAUXFMPU!FSTEANSUPPLYVALVEBATMSALRt(RXTRIPPEDALII8.31763K)I 60098.66958~01 60091.01391-11 60091.01391-11 6009.0060091025.LALt(41.6600D12.6INHB109,46009TRIPPEDALfiNOTTRIP600977.9600~53.5600936.160091024.6009469.LALMTRIPPEDALRt(TRIPPEDALIITRIPPEDALRt(TRIPPEDALIINOTTRIPDELNOTTRIPDELNOTTRIPALRt(NOTTRIPALRt(-.21GOOD2.4HWRNLO)(ER6009LONERG009LONER6009LONER6009LONER6009LO))ER6009LO)tER6009LO)tERGOODLO)tER6009LO))ER6009472.76009471.8GOOD469.66009469.46009471.2GOOD470.6600999.96009471.5600~0.6009196.6009OFF6009ON6109CLOSEDGOODCLOSED6009CPSCPSAMPAMP'/PSIGX//KGFXPSIGPSI6PSIGDE6FDEGFOE6FDEGFDEGFDE6FXDE6FPNGPM OCT8>199211:15R.E.GINASINULATOR TRENDGROUPASSIGNNENT RNMYPA6E2POINTID53FSIA54FGIB55P216056P216157BKR04158BKR04259BKR04360BKR044DESCRIPTION SAFETYINJECTION:LOOP AAV6FLONSAFETYINJECTION LOOPBAVGFLONSERVICENATERPUIIPSAhBHEADERSERVICEHATERPNPSChDHEADERSERVICENTERPUIIPASERVICENATERPlIPBSERVICENTERPIIPCSERVICEHATERPUIIPDVALUEQUALE.U.0.GOOD0.Goon72.600D80.GoonGoonON600DON600DONGOODGPt1GPtlPSI6PSIGGROUP:EVENT1PRXEDURE: EPIP1-5PLANTSTATUS ~~ROGRAMNAME:LRGTSZ.E R.E.GIHNANUCLEARPOWERPLANTOCT08,9211:15:00TRENDGROUPASSIGNHEHT SUMMARYGROUPNAMEEVENT2GROUPDESCRIPTIONPROCEDURE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURRENTVALUEDUALITYCODEENGRUNITS1234567891011121314202122232425262728293031323334353637383940414243F0619LRWSTWS033WD033WT033WT250WOT2R01R02R05R09R34R35R10AR11R12R10BR13R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14A5R14A7R14A9R15ASR15A7R15A9R31R32CVHTCV03TCV07TCVOBTCV09TCV10TCV17COMPOHENT COOLINGLOOPTOTALFLWREFUELING WATERSTORAGETANKLVL33FOOTLEVELWINDSPEED33FOOTLEVELWINDDIRECTION 33FOOTLEVELTEKPERATURE 250FOOTLEVELTEMPERATURE 250TO33FOOTLEVELDELTATEMPAREA1-COHTROL ROOKAREA2-CONTAINMENT AREA5-SPENTFUELPITAREA9LETDOWNLINEMONITORAREA34-AUXBLDGCVSPRAYPUHPAREA35-PASSSAMPLEPAHELCONTAINMENT IOOIHEMONITORR10ACONTAINMENT AIRPARTICULATE COHTAINKEHT GASMONITORPLANTVENTIOOIHEMOHITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASKONITORLIQUIDWASTEDISPOSALMONITORSTEAMGENERATOR SLOWDOWNDRAINAREA29-CONTAINMEHT HIGHRANGEAREA30-CONTAIHMEHT NIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LOWRANGEGASCVVENTCHAN6-AREAGAMMACVVENTCHAN7-MIDRANGEGASCVVENTCHAN9-HIGHRANGEGASPLANTVENTCHAN5-LOWRAHGEGASPLANTVENTCHAN7-MIDRAHGEGASPLANTVEHTCHAN9-HIGHRANGEGASAIREJECTORCHAN5'OWRANGEGASAIREJECTORCHAN7-MIDRAHGEGASAIREJECTORCHAN9-HIRANGEGASAREA31STEAMLINEA(SPING)AREA32STEAMLINE8(SPING)CVHYDROGENCONCEHTRATIOH CVBASEMENTLVL6FTTEMP¹3CVINTERMEDIATE LVL6FTTEMP¹7CVINTERMEDIATE LVL6FTTEMP¹8CVINTERMEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEMP¹10CVOPERATING LVL6FTTEMP¹171485.94.55.680.62.564.92.49.02214-02 7.35678+00 1.3994&001.36701+02 9.09354-01 1.09283+00 9.58719+01 5.18901+02 7.38002+02 4.30543t01 8.58327+01 4.22831+01 2.78658+03 1.32174+04 5.05861.01 5.09440-01 1.57835+03 1.89699-07 2.53990.02 3.57435-05 1.41261-03 4.40312.07 6.86543-05 3.72621-03 2.09411-07 1.34492-05 1.27941-03 2.50040+00 1.01048-02.095.1106.0106.6106.7106.2117.5GmmGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODNALKGOODGOODGOODGOODGOODGOODGOODGOODGPMXKPHDEG.DEGFDEGFDEGFKR/HMR/HMR/HMR/HKR/HMR/HCPHCPKCPKCPMCPMCPKCPKCPMR/HRR/HRCPMUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCKR/HRMR/HRDEGFDEGFDEGFDEGFDEGFDEGF Time:1120Message:41INNASTATION'I92EVALUATED EXERCIEMESSAGEFORM~MI:TPIIRpp<<C<<IIPCRpITSimulaedPlanCondiions:~Messee:"""THISISANEXERCISE""" The"A"S/GARVmercoidisrepairedandreadyforreturnforservice.FORCONTROLLER USEONLYController Notes:1)TheIRCRepairTeamworkingonthe"A"S/GARVMercoidshouldreportthismessagetotheTSC.TSCCnrollerandISCReairTeamConrollerocoordinate thisreorat1120hours.AnticiatedResults;1)Operators performing Applicable ActionsofES-3.1(PostSGTRCooldownUsingBackfill). 2)Operators performing Applicable ActionsofER-AFW.1, 3)Operators shouldreturnthe"A"S/GARVtoserviceifrequested bytheTSC.4)TSCevaluating Plantconditions andtakingactionwhererequired. 5)TSCmayrequestControlRoomtoreturnthe"A"S/GARVtoservice.(continued onnextpage) 6)Securityshouldbeevaluating theDrilledHoleinthe"B"S/GARVPipe.7)EOFshouldbeassessing Plantconditions andtakingactionasrequired. 8)EOFDoseAssessment shouldbeperforming offsiteDoseAssessment asrequired, inparallelwiththeTSCDoseAssessment. 9)TheEOFshouldbeassumingcommandandcontrolatapproximately thistime.10)Repairteamsperforming actionsasrequiredtoreturnequipment toserviceassoonaspossible. 11)TheMobileDlUnitshouldbeconnected andinoperation andtheinsidecondensate storagetanksshouldbebeingfilled. Time:~12Message:42INNASTATION12EALTEDEXEIE~MEEAEFRM~MI:AIIIMRF<<<<R'A'IRARESimulaedPlantCondiions:SeetheAttachedMini-Scenario ~Meeee:"""THISISANEXERCISE""" FORCONTROLLER USEONLY~CIIE1)Provideinformation verballywhenappropriate actionsaresimulated bytheAuxiliary Operatorsenttoreturnthe"A"S/GARVtoservice.AniciatedResults:1)AsperMini-Scenario Anticipated Results. ~INNIITNN12EVALUATED EXERISEM~ININNNNIII~A~iviy:Returntoserviceofthe"A"S/GARVFORCONTROLLER USEONLY1)EnsureAuxiliary Operatorsimulates openingManualValve3507("A"S/GARVIsolation Valve).2)EnsureAuxiliary Operatorsimulates checkingManualValve3507A("A"S/GARVIsolation Valve,BypassValve)closed.3)Controller mustnotifytheSimulator ControlBoothOperatoratExt.6641tocoordinate actionsonthisMini-Scenario. N1)Auxiliary Operatorshouldsimulatereturning toService(i.e.unisolating) the"A"S/GARV.2)Auxiliary

Operator, aftersimulating returntoserviceofthe"A"S/GARV,shouldinformControlRoom/TSC.

3)ControlRoommayplace"A"S/GARVtoAutomatic Control. Time:11'essage: ~4INNATATIN12EVLATEDEXEIEMESSAGEFORMI:RII<<RIRSimlaePlanCndiion:SeetheAttachedSheets~Massae:"""THISISANEXERCISE""" FORCONTROLLER USEONLYController Ntes:AniciatedResults:1)Operators performing theApplicable ActionsofES-3.1(Post-SGTR CooldownUsingBackfill). 199EVALUATED EXERCISETime://3OMOORPARAMETERS "'NGINEERED SAFEGUARDS A.RUNNINGUNLOADEDTBOOSB.RUNNINGUNLOADEDSTBYOOSTSCRUNNINGUNLOADEDOOSSecurityRUNNINGUNLOADEDTBENGINEERED SAFEGUARDS OOSAux.Feedwatems1A.INSERVBOOS1B.NSERSTBYOOSTurb.DrivenINSERVTBOOSCSTLevelFEET"ReactorShutdownESNON-31~~CPSN-32CPSN-35&IAMPSN-36gl/AMPSAvg.NuclearPowerRCSPressure~bZPSIGPRZRLevel&7ARCPRUNNINGTOPPEBRCPRUNNINSTOPPED1AS/GLevel.Ca1BS/GLevelMV1AS/GPressureoOPSIG1BS/GPressure0PSIGTurbine/Generator ONLINEFFLIN4KVBusesNERGZZDEENERGIZED 480VBusesERGZZEDEENERGIZED DCBatteries A~SoVOLTSB/3OVOLTS CnmtPressurePSIGCnmtSumpALevel~a<+FEETCnmtSumpBLevelINCHESALoopHotLegS7OFALoopColdLeg.0OFBLoopHotLegQ~OOFBLoopColdLeg%XKZoFRVLIS*CET~.bOFS/GATotalAuxFWFlow~GPMS/GBTotalAuxFWFlowZ.o2GPMDIESELGENERATORS HihHeadS.I.PumsFI-924OGPMF1-925~GPM1A.INSERVBOOS1B.INSERVBOOS1C.INSERVOOSBASTLevel=/OLowHeadS.I.PumsFI-626NGM1A.INSERVOOSRECIRC1B.INSERVTOOSRECIRCRWSTLevel=S.Containment SraPumsFI-931A&GPMFI-931BlDGP1A.INSERV1B.INSERVTNaOHTankLevel=OOSOOSContainment RecircFans1A.NSERVSTBYOOS1B.SESTBYOOS1C.SERSTBYOOS1D.NSERSTBYOOSPostAccdentDampersPECLOSEDServiceWater-Pum s1A.INSERVSTBY01B.NSESTBYOOS1C.NSESTBYOOS1D.NSERSTBYOOSA&BHeaderPressure~PSZGComonentCoolinWaterPums1A.IERVSTBY1B.NSERSTBYOOSSurgeTanvelStandbAux.Feedwater Pums1C.INSERVTBOOS1D.INSERVSTBOOS*CET=AverageofSelectedCoreExitThermocouples 8i199211:30R.E.6INASINLATORTRENDGROUPASSIGN)(ENT SUt(t(ARY PA6E16ROUP:EVENT1PROCEDURE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION VALUEE.U.12345b789101112131415ib1718192021222324252b27')8293031323334353b37383940414243454b474849505152ATI6RXTN31N32N35N3bi"(PPRCSLPIRFRCLAFRCLBRXT1bRXT17TSUBTCLSGALS6BPSGAPSGBGENBKR1GENBKR2BUS11ABUS118BUS12ABUS12BBiIA12AB11B12BPCVLSNPAL0942EL0943EL0942DL0943DL0942CL0943CL0942BL0943BL0942AL0943AT0409AT0410AT0450T0451TAVGAMIDTAVGBMIDLRVTCCOREFAUXFMAFAUXFWBBKR081BKR082V3505V3504ANTICIPATED TRAt(6IENT W/0SCRAt(REACTORTRIPBREAKERSTATUSSSSCERANGEDETECTORN-31SONCERANGEDETECTORN-32INTERt(EDIATE RANGEDETECTORN-35INTERt(EDIATE RANGEDETECTORN-3bAVERAGENUCLEARPOWERREKTORCOOLANTSYSTEtlAVGPRESSPRESSURIlER AVERAGELEVELREACTORCCEA(TLOOPAAVGFLOWREACTORCOOLANTLOOPBAVGFLOWRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCORETCSUP3NLEDt(ARGINSTNGENANARROWRANGEAVGLEVELSTNGENBt(ARROWRAKEAVGLEVELSTt(GEttAAVERAGEPRESSURESTNGENBAVERAGEPRESRJREGENERATOR ONLINE%FAKER161372GENERATOR ONLINEBREAKER9X1372BUS11ASUPPLYBREAKERBUSliBSUPPLYBREAKERt(QTTERNlhATED OMPPCS(7/19/91) NOTTERtlit(ATED OMPPCS(7/19/91) BUS11ATO12ATIEBREAKERBUSiiBTO12BTIEBREAKERCOl(TAINl"iENT AVERAGEPRESSURECQNTAItit(Et(T SUMPAAVERAGELEVELSM'LEVEL8INCHES(TRAINA)SMBLEVEL8INCHES(TRAINB)SUt(PBLEVEL78INCHES(TRAINA)SU@'LEVEL78INCHES(TRAINB)SUN'LEVEL113INCHES(TRAIN A)SM~BLEVEL113INCH.=S(TRAIN B)SU%BLEVEL180INCHES(TRAIN A)SUtPBLEVEL180INCHES(TRAIN B)SU%'LEVEL214INCHES(TRAIN A)S"tPBLEVEL214It/CHES(TRAIN B)RCLAHOTLEGTEt(PERATUP= RCLBHOTLEGTEt(PERATUK RCLACPDLEGTE)PERATURE RCLBCOLDLEGTEt(PERATNE RCLATAVG(THQT/TCOLD WIDERNG)RCLBTAVG(TNT/TCOLD WIDERNG)REACTORVESSELA'FRAGELEVELE1.1INCOFETCAVERAGETEt(PS/GATOTALAUXFEEDWATER FLO((S/GBTOTALAUXFEEDMATER FLOWt(TRAUXILIARY FEEDMATER PUt(PAMTRAUXILIARY FEEDMATER PUt(PBAUXFMPUPSTEANSUPPLYVALVEAAUXFMPU5'TEANSUPPLYVALVEBATMSRXTRIPPED8.75988+017.92501+01 1.01391-11 1.01391-11 .001002.41.712.8110.8TRIPPEDNOTTRIP90.148.b34.91000.401.TRIPPEDTRIPPEDTRIPPEDTRIPPEDNOTTRIPNOTTRIPNOTTRIPNOTTRIP-.24LONERLOMERLOWERLONERlONER,LONERLOWERLOWERLONERLONER457.8457.0455i0454.845b.4455.999.945b.b0.202.OFFONCLOSEDCLOSEDALRt(ALRt(6(mDGOODGOODGOODGOODGOODGOODINHBGOODALRt(GOOD600~600DGOODGOODLALNALRt(ALRt(ALRtlALRt(DELDELALRt(ALR)(GOODSlRt(GOOD600DGQODGOOD6009GOODGOOD600D600D600DGOODGOODGOODGOODGOODGOODGOOD600~GOODGOOD600DGOODGOODGOODCPSCPSAt(PAt(Py.PSIG//DEGF/7.PSIGPSIGPS16FMDEGFDEGFDE6FDE6FDEGFDEGF7.D-"GF6PNGPt( OCT8i199211:30R.E.GINASINLATORPAGE2TRENDGROUPASSIGNMENT 9NMY6ROUP:EVBP1PROCEDURES EPIP1-5PLNITSTATUSPOINTIDDESCRIPTION VALUEQUALE.U.53FSIA54FSIB55P216056P216157BKR04158BKR04259BKR04360NR044SAFETYINJECTION LOOPAAV6FLOWSAFETYINJECTION LOOPBAV6FLOMSERVICEMATERPlmPSAhBHEADERSERVICEWATERPNPSC59HEADERSERVICEMATERPINPASERVICEMATERPUNPBSERVICEWATERPUNPCSERVICEWATERPUeD0.Gxam0.GOODGPN72.GOODPSIG80.600DPSIGGOODGOOD6OODGOOD ~~~ROGRAHKAME:LRGTSZ.E R.E.GIKHANUCLEARPOWERPLANTOCT08,9211:31:00TRENDGROUPASSIGNMENT SUMMARYGROUPNAMEEVENT2GROUPDESCRIPTION PROCEDURE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURRENTVALUEQUALITYCODEENGRUNITSl.234567891011121314202122232425262728293031323334353637383940414243-F0619LRWSTWS033WD033WT033WT250WDT2R01R02RDSR09R34R35R10AR11R12R108R13R14~R18R19R29R30R15R12ASR12A6R12A7R12A9R14A5R14A7R14A9R15ASR15A7R15A9R31R32CVHTCV03TCV07TcvoeTCV09TCV10TCV17COMPOHENT COOLINGLOOPTOTALFLWREFUELING WATERSTORAGETANKLVL33FOOTLEVELWINDSPEED33FOOTLEVELWIHDDIRECTION 33FOOTLEVELTEHPERATURE 250FOOTLEVELTEHPERATURE 250TO33FOOTLEVELDELTATEHPAREA1-CONTROL ROOMAREA2-COHTAINHEHT AREA5-SPENTFUELPITAREA9-LETDOWN LIHEMOHITORAREA34AUXBLDGCVSPRAYPUHPAREA35-PASSSAHPLEPANELCONTAINMENT IODINEMONITORR10ACONTAINHEHT AIRPARTICULATE CONTAINMEHT GASMONITORPLANTVENTIODINEMONITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMOHITORLIQUIDWASTEDISPOSALMONITORSTEAMGEKERATOR BLOWDOWNDRAINAREA29-CONTAINMENT HIGHRANGEAREA30.CONTAINMEHT HIGHRANGECOKDEHSER AIREJECTOREXHAUSTCVVENTCHAN5-LOWRANGEGASCVVENTCHAN6-AREAGAMMACVVEN'ICHAN7-MIDRAHGEGASCVVENTCHAN9-HIGHRANGEGASPLANTVENTCHAN5-LOWRANGEGASPLAHTVENTCHAN7-MIDRANGEGASPLANTVENTCKAN9-HIGHRAHGEGASAIREJECTORCHAN5-LOWRANGEGASAIREJECTORCHAN7-MIDRANGEGASAIREJECTORCHAN9HlRANGEGASAREA31STEAMLINEA(SPING)AREA32STEAMLINE8(SPING)CVHYDROGENCONCEHTRATIOH CVBASEHENTLVL6FTTEMP¹3CVINTERMEDIATE LVL6FTTEMP¹7CVINTERMEDIATE LVL6FTTEMP¹8CVINTERMEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEMP¹10CVOPERATIKG LVL6FTTEMP¹171485.94.55.679.62.764.82.19.02214-02 7.35678+00 1.39946+00 1.34701+02 9.09354-01 1.09283+00 9.58719+01 5.18901+02 7.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658+03 1.28174+04 5.05861-01 5.09440-01 1.57835+03 1.89699.07 2.53990-02 3.57435-05 1.41261-03 4.40312-07 6.86543-05 3.72621-03 2'9411-071.34492-05 1.27941-03 2.50040+00 1.01048.02 .095.1106.0106.6106.7106.2117.5GOODGOODGOODGOODGOODGOGOQXX)GOOD0000GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODBALMGOODGOODGOODGOODGOODGOODGOODGOODGPHXMPHDEG.DEGFDEGFDEGFMR/HMR/HMR/HMR/HMR/HMR/HCPHCPHCPHCPMCPHCPMCPMCPMR/HRR/HRCPHUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/NRMR/HRXDEGFDEGFDEGFDEGFDEGFDEGF Time:~114Message:'44INNATATIN192EVALUATED EXERISEMESAEFRM~hlf:ThlfhppplPlpflPWldhplTimulaePlnniin:~lVIs~sae:"""THISISANEXERCISE""" 'he"B"S/GARVsteamleakisrepairedandreadyforreturntoservice.FORCONTROLLER USEONLYC~fl1)ThePipefitter 5.WelderRepairTeamworkingonthe"B"S/GARVsteamleakshouldreportthismessagetotheTSC.TConrIIrnPifir5WIrReirTmConrollrrinhira114hr.'AniciaedReIs:1)TSCshouldrequestControlRoomtoreturnthe"B"S/GARVtoservice.2)Operators shouldreturnthe".B"S/GARVtoservice, Time:~114Message:~4INNATATIO2EVLATDXEIEMESSAGEFRMt:AitiyDp<<<<<<1"B"SIGARVtmulePlnniin:SeetheAttachedMini-Scenario ~Massae:"""THISISANEXERCISE""" FORCONTROLLER USEONLYController Notes:1)Provideinformation verballywhenappropriate actionsaresimulated bytheAuxiliary Operatorsenttoreturnthe"B"S/GARVtoservice.2)Controller mustnotifytheSimulator ControlBoothOperatoratExt6641tocoordinate actionsonthisMini-Scenario. AniciaeReIs:1)AsperMini-Scenario Anticipated Results. INNASTATION192EVALUATED EXERCISEMINI-EMARI~A1~Iviy:Returntoserviceofthe"B"S/GARVFRCONTROLLER USEONLY1)EnsureAuxiliary Operatorsimulates openingManualValve3506("B"S/GARVIsolation Valve).2)EnsureAuxiliary Operatorsimulates checkingManualValve3506A("B"S/GARVIsolation Valve,BypassValve)closed.AnticiaedResuls:1)Auxiliary Operatorshouldsimulatereturning toservice(i.e.,unisolating) the"B"S/GARV.2)Auxiliary

Operator, aftersimulating returntoserviceofthe"B"S/GARV,shouldinformControlRoom/TSC.

3)ControlRoomshouldplace"B"S/GARVtoautomatic control~ Time:~114Message:~4INNATATIN12EVALATEDEXERE~MEAEFORM~MI:MI<<C<<IRSimulaedPlanCondiion:SeetheAttachedSheets~Massae:"""THISISANEXERCISE""" FORCONTROLLER USEONLYAnticiatedResits:1)Operators performing theApplicable ActionsofES-3.1(Post-SGTR CooldownUsingBackfill). 2)TSCevaluating Plantconditions andtakingactionasrequired. 3)TSCshouldrequestControlRoomtoreturnthe"B"S/GARVtoservice.4)EOFevaluating Plantconditions andtakingactionasrequired. 199PEVALUATED EXERCISETXme://'/5MAZORPAMMETERS ENGINEERED SAFEGUARDS HihHeadS.Z.PumsFI-924C7GPMFI-925&GPMINSERVTBOOS1B.ZNSERVBOOS1C~INSERVTBOOSBASTLevel=/OLowHeadS.I.PumsFZ-626OGPM1AINSERVTBOOSRECIRC1B.INSERVTBOOSRECIRCRWSTLevel=Containment SraPumsFZ-931A&GPMFI-931B&GPM1A.INSERVTOOS1B.INSERVTBOOSNaOHTankLevel=Containment ecircFanslA.SSTBYOOS1B.NSSTBYOOS1C.SESTBYOOS1D.NSESTBYOOSPostAccidentDampersOPECLOSEDServiceWaterPums1A.INSESTBYOOS1B.NSERVSTBYOOS1C.SERSTBYOOS1D.NSERSTBYOOSA&BHeaderPressure7&&70PSZGDIESELGENERATORS A.RUNNINGUNLOADEDTBOOSB.RUNNINGUNLOADEDTBOOSTSCRUNNINGUNLOADEDTBYOOSSecurityRUNNINGUNLOADEDBComonentCoolinWaterPums1A.IVSTBY1B.NSEVSTBYOOSSurgeTankLevel=~/StandbAux.FewaterPums1C.INSERVTOOS1D.INSERVTBOOSOOSENGINEERED SAFEGUARDS Aux.Feedwater Pums1A.INSERVOOS1B.INSERVTBOOSTurb.DrivenINSERVBOOSCSTLevel~gFEET*CET=AverageofSelectedCoreExitThermocouples ReactorShutdownYESNON-31~~CPSN-32CPSN-35~0-IIAHPSN-36~-I/AMPSAvg.NuclearPowerRCSPressure'f7PSIGPRZRLevel~&.3ARCPRUNNINGOPPBRCPRUNNINSTOPPED1AS/GLevel~sd&1BS/GLevel~)a71AS/GPressure~~PSIG1BS/GPressurePSIGTurbine/Generator ONLINEFFI4KVBusesNERGIZEDEENERGIZED 480VBusesNERGIZEDEENERGIZED DCBatteries A~VOLTSB/30VOLTS CnmtPressure~ZCaPSZGCnmtSumpALevelFEETCnmtSumpBLevelINCHESALoopHotLeg~3.Z.OFALoopColdLegWla7OFBLoopHotLeg~~3.OFBLoopColdLeg'~l.hOFRVLIS*CET.3OF.S/GATotalAuxFWFlowOGPMS/GBTotalAuxFWFlowOGPM Gi199211:45R.E.GINASlt(ULATOR TREND6ROUPASSIG)NENT SUt)t(ARY PAGE16ROUP:EVENTlPROCEDURE: EPIP1-5PLANTSTATUS12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152POINTIDATMSRXTN31N32N35N36HPPRCSLPLRFRCLAFRCLBRXT16R)(T17TSUBTCLSGALSBBPSBAPSBBGENBKRlGENBKR2BUS11ABUS11BBUS12ABUS12BBllA12A811B12BPCVLSI(PAL0942EL0943EL0942DL0943DL0942CL0943CL0942BL0943BL0942AL0943AT0409AT0410AT0450T0451TAVBAMIDTAVBBMIDLRVTCCQREFAUXFMAFAUXFMBBKR081BKR082V3505V3504DESCRIPTION ANTICIPATED TRANSIENT W/0SCRAttREACTORTRIPBRENERSTATUSSISCERANGEDETECTORN-31SISCERANGEDETECTORN-32INTEI(t(EDIATE RANBEDETECTORN-35INTER)(EDIATE RANBEDETECTORN-36AVERAGENUCLEARPOWERREACTORCOOLANTSYSTEttAVGPRESSPRESSURIIERAVERA6ELEVELREKTORCQOUNfLOOPAAVBFLOWREACTORCOOLAt(TLOOP8AVBFLOWRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCORETCSUBCOOLED MARINSTttGEHAHARROMRANGEAVGLEVELSTMGENBt(ARROWRA%EAVGLEVELSTMGENAAVERAGEPRESSURESTt(GENBAVERAGEPRESSURECBERATORONLINEBRENER161372GENERATOR ONLINEBREAKER9X1372BUS11ASUPPLYBRENERBUS118SUPPLYBRENERNOTTERNINATED ONPPCS(7/19/91) NOTTERHINATED Qt(PPCS(7/19/91) BUSllATO12ATIEBREAKERBUS119TO12BTIEBREAKERCQNTAINtiENT AVERAGEPRESSURECONTAltitlEhT S)iPAAVERAGELEVELSUtPBLEVEL8INCHES(TRAIt(A)SUtPBLEVEL8INCHES(TRAIN9)SUtP8LE4S.78INCHES(TRAINA)SU)PBLEVEL78INCHES(TRAINB)SUtPBLEVEL113It(CHES(TRAIN A)SUtPBLDH,113It(CHES(TRAIN B)SUtPBLEVEL180INCHES(TRAIN A)SUtPBLE4S.180INCHES(TRAIN B)SUtPBLEVEL214INCHES(TRAIN A)SUtPBLEVEL214INCHES(TRAIN B)RCLAHOTLEGTFt1PER4T()K RCEBHOTLEGTE5'ERATURE RCLACOLDLEGTEt(PERAT(SE RCLBCOLDLEGTEt)PERATURE RCLATAVB(THOT/TCQLD WIDERNB)RCLBTAVG(THAT/TCOLD WIDERNB)REACTORVESSELAVERAGELEVELEl.lIHCORETCAVERAGETEt(PS/GATOTALAiJXFEEDMATER FLOWS/6BTOTALAUXFEEDMATER FLS(t(TRAUXILIARY FEEDMAmi.Put(P4t)TRAUXILIARY FEEDMATER PUt)P9AUXFWPU)(PSTEA)tSL4'PLYVALVEAAUXFWPU5'TEAt) SL'PPLYVALVEBOFFOFFCLOSEDCLOSEDVALUEQUALATMSALIIRXTRIPPEDALR)(7.87043+01 60098.34639%1 60091.01391-11 60091.01391-11 6009.006009976.600946.3600912.9INHB111.96009TRIPPEDALRttNQTTRIP6009100.1600e42.5600940.76009973.6009350.LALNTRIPPEDALQfTRIPPEDALR)(TRIPPEDALRNTRIPPEDAUINQTTRIPDELNOTTRIPDELNOTTRIPALRt(NOTTRIPALRtf-.2660092.4tIRt(LONERG009LOMERGOODLOMERGOODLOMERGOODLOMERGOODLOMcRGOODLOMER6009LOMERGOODLOMER6009LOMER6009443.26009443.46009441.76009441.56009442.4GOOD44'.5GOOD99.86009443.3600e0.60091.6009GOOD69096009GOODE.U.CPSCPSAt(Py.PSIGX7.zDEGFXXPSIGPSIGPSIGFcCTDEBFI)EGFt)EGFDEGFKGF066Fy.DEGFGP)(GPt( OCTBi1992il:45R.E.GINASINLATORTRENDGSPAKIGNENTRNNRYPAGE2.6ROUP:EVENT1PROCEDURE: EPIP1-5PLANTSTATUSPOINTID53FSIA54FSIB55P21b056P216157BKR04158BKR04259BKR043h0BKR044DESCRIPTION SAFETYINACTION'LOCH AAVGFLOWSAFETYINJECTION LOOPBAVGFLOWSERVICEWATERPtNPSAhBHEADERSERVICEWATERPNPSChDHEADERSERVICEWATERPUNPASERVICEWATERPUNPBSERVICEWATERPUNPCSERVICEWATERPUNPDOFFONONON0.0.72.80.QUALE.U.6009GPN600DGPNGOODPSI6600DPSIGGOODGOODGOODGOODE+3 ROGRAMHAME:LRGTSZ.E R.E.GINHANUCLEARPSIERPLANTOCT08,92114700TRENDCROUPASSIGNMENT SUMMARYGROUPNAMEEVENT2GROUPDESCRIPTION PROCEDURE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURRENTVALUEQUALITYGX)EENGRUNITS1234567891011121314202122232425262728293031323334353637383940414243F0619LRMSTUS03340033l6033lIT250lOT2R01R02R05R09R34R35R10AR11R12R10BR13R14R18R'19R29R30R15R12A5R12A6R12A7R12A9R14A5R14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03TCV07TCVOBTCV09TCV10TCV17C(NPONEHT COOLINGLOOPTOTALFLIIREFUELIMG lIATERSTORAGETANKLVL33FOOTLEVELlIIHDSPEED33FOOTLEVELIIIHDDIRECTION 33FOOTLEVELTEMPERATURE 250FOOTLEVELTEMPERATURE 250TO33FOOTLEVELDELTATEMPAREA1-CONTROL ROOHAREA2-CONTAINHENT AREA5-SPENTFUELPITAREA9-LETDSIN LINEMONITORAREA34-AUXBLDGCVSPRAYPUHPAREA35-PASSSAHPLEPANELCONTAINMEHT IODINEHOHITORR10ACONTAINMENT AIRPARTICULATE CONTAINHENT GASMONITORPLANTVENTIODINEMONITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIQUIDIIASTEDISPOSALMONITORSTEAHGENERATOR BLSNSIMDRAINAREA29-CONTAIMHENT HIGHRANGEAREA30-CONTAINMEHT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LSIRANGEGASCVVENTCHAN6AREAGAHMACVVENTCHAN7-MIDRANGEGASCVVENTCHAN9-HIGHRANGEGASPLANTVENTCHAN5-LOlIRANGEGASPLANTVENTCHAN7-MIDRANGEGASPLANTVENTCHAN9-HIGHRAMGEGASAIREJECTORCHAN5-LSIRANGEGASAIREJECTORCHAN7-HIDRANCEGASAIREJECTORCHAN9-MIRANGEGASAREA31STEAMLINEA(SPING)AREA32STEAMLINE8(SPING)CVNYDROGENCONCENTRATION CVBASEMENTLVL6FTTEHP¹3CVINTERMEDIATE LVL6FTTEMP¹7CVINTERMEDIATE LVL.6FTTEMP¹8CVINTERMEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEHP¹10CVOPERATING LVL6FTTEMP¹171485.94.56.276.65.066.81.89.02214.02 7.35678+00 1.39946+00 1.32701+02 9.09354-01 1.09283+00 9.58719+01 5.18901+02 7.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658+03 1.28174+04 5.05861-01 5.09440.01 1.57835+03 1.89699-07 2.53990-02 3.57435-05 1.41261-03 4.40312-07 6.86543-05 3.72621-03 2.09411-07 1.34492-05 1.27941-03 2.42040100 1.01048-02 .095.1106.0106.6106.7106.2117.5GOODGOOD60(OGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODQXOGOODGOOD6000BALMGOODGOCDGOODGOODGOODGOOD6000GOODGOODGOODGOODMALH60006000CODDCODDGOODGOODCOODCOCOGPMXMPMDEG.DEGFDEGFDEGFMR/NHR/HMR/HHR/HMR/HMR/MCPMCPMCPHCPHCPMCPMCPMCPMR/HRR/MRCPHUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCHR/MRMR/HRXDEGFDEGFDEGFDEGFDEGFDEGF0-J Time:~114Message:~4l~INNATATIN12EVALEEERIEMESSAEFORMMMMf:ICFFffffdgIMF,VICSupportStaff,Engineering SupportCenterStaffimlPIi:SeetheAttachedMini-Scenario ~IVles~a"""THISISANEXERCISE""" FORCONTROLLER USEONLY~glg1)Provideinformation verballythatseveralRochester Telephone phonesetsareinoperable duetoanunspecified cause.AnticiatedResults:1)AsperMini-Scenario Anticipated Results. GINNASTATION192EVALUATED EXERCISEIVIINI-SCENARIO TITLE:EOFTelhoneSsemFilreExpectedscenariostarttime:1145INITIALCONDITIONS: Centrex,Rochester Telephone andNewYorkTelephone extensions operable. METHODOFINITIATION: EOFandESCControllers informEOFandESCStaffthatseveralRochester Telephone extensions arenotworking.INDICATIONS: Controllers shouldhavetagsreadytoplaceonphonesetsindicating theyarenotfunctional. EXPECTEDSEQUENCEOFACTIONS:2.Voicecommunications stafftoinitiateinvestigation oncauseoftelephone systemmalfunction. 1Appropriate announcements madetoEOFandESCstaffs.Voiceandfaxcommunications shouldbetransferred toalternate telephone systems.EOFDoseAssessment mayneedtoobtainweathertowerdatathroughalternate telephone extension. FINALCONDITIONS: Playerswillbegivencreditforactionstaken.Telephones willnotberestoredbeforetheendoftheexercise. 8-/66 Time:~114Message:~42~INNATATIN2EVALATEDXERIEMEAEFORMNNNNNLIAL: NIhdhdIThII<<ICIhTNC.imladPlanCnditions: SeetheAttachedMini-Scenario ~Me~a"""THISISANEXERCISE""" FRONTROLLER USEONLY~CN1)HealthPhysicscontroller mayalarmthefriskerprobewithachecksourcetosimulatecontamination foundonhisshoesandclothing. AniciaedResul1)AsperMini-Scenario Anticipated Results. INNATATIN12EVALATEDEXERIEMINI-SENARITITLE:inIn'vIrivinhExpectedscenariostarttime:1145INITIALCONDITIONS'risking stationsandstep-offpadssetupatTSCentrances. METHODOFINITIATION: HealthPhysicscontroller alarmsthefriskerprobewithachecksourcetosimulatecontamination onhisshoesandclothing. INDICATIONS: Controller shouldprovidesimulated readingstoHPtechnician responding tofriskeralarm.Bottomsofshoes:2000cpmSocksandpantcuffs:500cpmFloorareasatTSCentrance: 200-1000cpmEXPECTEDSEQUENCEOFACTIONS:2.3.4.5.HPtechnician respondsandconductsmonitoring ofcontaminated individual. HP/Chemistry Managerisinformed. TSCentrancesecuredtopreventfurtherspreadofcontamination. Follow-up actionsrequiredbyHP-6,3areinitiated fordocumentation anddecontamination. Technicians shouldinvestigate andsurveyforextentofcontamination spreadwithinTSCandareasoutsideofTSC.(Controller willprovidereadingstoplayersasrequested). FINALCONDITIONS: HealthPhysicsController togivecreditfordecontamination andcontamination controlactionstaken.Readingstobereducedasappropriate, depending onactionstaken. Time:~QQMessage:47~INNATATI~192EVALATEDEXERIE~MESSARFRM~IMI:MI<<F<<IRSimulated PlanConditins:SeetheAttachedSheets~Messse:"""THISISANEXERCISE""" FORCONTROLLER USEONLYConrollerNoes:AniciaedResuls:1)Operators performing theApplicable ActionsofES-3.1(Post-SGTR CooldownUsingBackfill), 2)TSCevaluating Plantconditions andtakingactionasrequired. 3)EOFPlantconditions andtakingactionasrequired. 199KEVALUATED EXERCISETime:/2OOENGINEERED SAFEGUARDS HihHeadS.Z.PumsMAZORPAE&METERS FI-924OGPMFI-9250GP1AINSERVTBOOS1B.INSERVTBYOOS1CINSERVOOSBASTLevel=LowHeadS.I.PumsFZ-626OGM1A.INSERVBOOSRECIRC1B.INSERVOOSRECIRCRWSTLevel=3.Containment SraPumsFI-931ADGPMFl-931BC7GP1A.INSERVBOOS1B.INSERVBOOSNaOHTankLevel=9'ontainment RecircFans1A.NSSTBYOOS1B.SERSTBYOOS1C.SESTBYOOS1D.NSESTBYOOSPostAccidentDampersOPENCLOSEDServiceWaterPums1A.ISTBYOO1B.SERSTBYOOS1C.STBYOOS1D.NSERSTBYOOSA&BHeaderPressurev~f'0PSIGDIESELGENERATORS A.RUNNINGUNLOADEDTBOOSB.RUNNINGUNLOADEDOOSTSCRUNNINGUNIADADED TBOOSSecurityRUNNINGUNLOADEDTBComonentCoolinWaterPumsOOSReactorShutdownESNON-31CPSN-32~CPSN-35~O~AAMPSN-36=WfAMPSAvg.NuclearPower0RCSPressure+@LPSZGPRZRLevel/ARCPRNGTOPPBRCPUNNINSTOPPED1AS/GLevelga21BS/GLevele.1AS/GPressurePSIG1BS/GPressure24PSZGTurbine/Generator ONLINFFLIN4KVBusesERGIZEDEENERGZZED 480VBusesNERGZZEDEENERGZZED DCBatteries AngeVOB/BOVOLTS CnmtPressure~2.PSIGCnmtSumpALevel~i,~FEETCnmtSumpBLevel@~iINCHESALoopHotLeg~>~70FALoopColdLegOFBLoopHotLeg~BA.QOFBLoopColdLegOFRVLIS~g*CETOF,S/GATotalAuxFWFlow0GPMS/GBTotalAuxFNFlow~a.GPMENGINEERED SAFEGUARDS Aux.Feedwater Pums1A.INSEVTBOOS1B.NSRSTBYOOSTurb.DrivenINSERVTBOOSCSTLevelF*CET=AverageofSelectedCore1A.ZNSEVSTBYOOS1B.NSERVSTBYOOSSurgeTankLevel=~/StandbAux.Feedwater Pums1C.INSERVTBOOS1D.ZNSERVTBOOSExitThermocouples Gi199212'00R.E.GINASit((LATOR TRENDGROUPASSIBNt(Et(T SUtft(ARY PAGE1GROUP:EVENTIPROCEDURE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION E.U.235678101112131415161718192021222324252627282930313233343536373839404142434446a74849505152ATI6RXTN31N32N35N36NPPRCSLPLRFRCLAFRCLBRXT16RXT17TSUBTCLSBALSGBPS6APSGBGENBKRIGB(BKR2BUS11ABUS118BUS12ABUS128811A12A8118128PCVLBNPAL0942EL0943EL09429L0943DL0942CL0943CL09428L09438L09a2AL0943AT0409AT0410AT0450T0451TAVGAW!9TAVGBMIDLRVTCCOREFAUXFWAFAUXFWBBKR081BKR082V3505V3504ANTICIPATED TRANSIENT M/0SCRufREACTORTRIPBREAKERSTATUSSONCERANGEDETECTORN-31SOlRCERAhGEDETECTORN-32It(TERt(EDIATE RANGEDETECTORN-35INTEfNEDI ATERANGEKTECTORN-36AVERAGEN(GERPOWERREACTORCOOLufTSYSTEtfAVGPRESSPRESSURIIER AVERAGELEVELREKTORCOOLANT(T LOOPAAVGFLOWREACTORCOOLANTLOOP8AVGFLOWRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCORETCSUBCOOLED t(ARGINSTffGEtfANARROWRANGEAVGLEVELSTtfGEN8t(ARROWRANGEAVGLEVELSTt(GEtfAAVERAGEPRESSURESTt(GEN8AVERAGEPRESSUREGENERATOR ONLINEBREAKER1G1372GEhERATOR ONLINEBREAKER'9X1372BUS11ASUPPLYBREAKERBUS118SlFPLYBREAKERNOTTERMINATED OffPPCS(7/19/91) NOTTERt(INATED ONPPCS(7/19/91) BUS11ATO12ATIEBRENERBUS118TO128TIEBRE(CERCONTAItft(ENT AVERAGEPRESSUREC0%'Aiht(ENT PJt(PAAVEfmGELEVELSUtf'LEVS.8It(CHES(TRAINA)SUtP8LEVEL8INCHES(TRAIN8)SUtf'LEVEL78JNCHES(TRAINA)SU%'LESS78INCI:ES(TRAIN8)SU@8LEVEL113INCHES(TRAIN A)SUtP8LESS.113INCHES(TRAIN 8)SUtf'LEVEL180INCHES(TRAIN A)SUtP8LEVEL180INCHES(TRAIN 8)PJtf'LEVS.214IhGfES(TRAIN A)SLtiP8LEVEL214INCHES(TRAIN 8)RCufHOTLEGTEf(PERATUR= RCLBHOTLEGTEt(PERATUK RCLACOLDLEGTEtfPERATNE PCLBCO'LEGTEtiPERATURE PCLATAVG(Tf(OT/TCOLD WIDERNG)R".U3TAVG(THDT/TCOLD WIDERNG)PEACTORVESS<<AVERAGELEVELEi.'t'COPE TCAVcBAGETEt'i~S!CATOTALAUXFEEDMAlS( FLOWS/G8TOTALAJXFEEDMATER FLOWt(TRAUXILIARY FEEBLERPUt(PAtfTRAUXILIARY FEEDMATER PU)fP8AUXFMPUt(PSTEAtfSUPPLYVALVEAAUXFMPUN'TEA)f SUPPLYVALVE8ATNSRXTRIPPED8.11894%1 8.09093%1 1.01391-11 1.01391-11 .00958.51.812.9112.5TRIPPEDNOTTRIP105.438.240.8953.326,TRIPPEDTRIPPEDTRIPPEDTRIPPEDNOTTRIPNOTTRIPNOTTRIPNOTTRIP~282.5LONERLONERLONERLONERLONERLONERLONERLONERLONERLONER434.7436.0434.6434.6434.6435.399.7435.90.42,OFFONCLOSEDCLOSEDALIIALfm6009600D6009GXD600960096009INHB600DALRtf6009600~600D60096009LALNALRtjALRtfALRt(ALRtfDELDELALRtfALRff6009HWRtf6009GOOD6009600D60096009GOOD600960096009600960096009GOOD60096009GOOD600~6009600D600D6()09GOOD6009CPSCPSAt(PAt(PXPSIGXX'XK6FXXPSI6PSIGPSI6FEETDEGFDEGFDEBFKGFDE6FK6FXKBFGPtf XTGs199212'00R.E.GINASINULATOR TRENDGROUPASSIGNENT SUNQRYPAGE2GROUPSEVENTiPROCEDURE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION VALUEQUALE.U.53FSIA54FSIB55P21605bP216157BKR04158BKR04259BKR04360BKR044SAFETYINJECTION.'LOOP AAVGFLOWSAFETYINJECTION LOOPBAVGFLOWSERVICEWATERPNPSA5BHEADERSERVICEWATERPmfPSChDHEADERSERVICEWATERPtNPASERVICEHATERPUffPBSERVICEWATERPlNPCSERVICEWATERPUtfPD0.0.72.80.OFFONONON600DGPtfGOODGPN6XDPSI6GOODPSIGGOODGOOD600D600D ~~ROGRAMNAME:LRGTSZ.E R.E.GINNAKUCLEARPOWERPLANTOCT08,9212:01:00TRENDGROUPASSIGNMEHT SUMMARYGROUPHAHEEVENT2GROUPDESCRIPTION PROCEDURE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURRENTVALUEQUALITYCODEENGRUNITS123456789101112131420212224252627282930313233343536373839404142430JF0619LRWSTWS033WD033WT033WT250WDT2R01R02R05R09R34R35R10AR11R12R108R13R14R18R19R29R30R15R12ASR12A6R12A7R12A9R14ASR14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03TCV07TCV08TCV09TCV10TCV17COMPONENT COOLINGLOOPTOTALFLWREFUELING WATERSTORAGElANKLVL33FOOTLEVELWIKDSPEED33FOOTLEVELWIKDDIRECTION 33FOOTLEVELTEMPERATURE 250FOOTLEVELTEMPERATURE 250TO33FOOTLEVELDELTATEHPAREA1-CONTROL ROOMAREA2-CONTAIHHEHT AREA5-SPENTFUELPITAREA9.LETDOWN LINEMONITORAREA34-AUXBLDGCVSPRAYPUMPAREA35-PASSSAMPLEPANELCONTAINHEHT IODINEMONITORR10ACONTAINMEHT AIRPARTICULATE CONTAINMEHT GASMOHITORPLANTVENT1OOIHEMONITORR108AUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIQUIDWASTEDISPOSALMOHITORSTEAMGENERATOR SLOWDOWNDRAINAREA29-CONTAINMENT HIGHRANGEAREA30-CONTAINMENT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LOWRANGEGASCVVENTCHAN6-AREAGAMMACVVENTCHAN7MIDRANGEGASCVVENTCNAH9-HIGHRANGEGASPLAHTVENTCHAN5-LOWRANGEGASPLAHTVENTCHAN7-MIDRANGEGASPLANTVENTCHAN9-HIGHRAKGEGASAIREJECTORCHAN5-LOWRAHGEGASAIREJECTORCHAN7HIDRAKGEGASAIREJECTORCHAN9-HlRANGEGASAREA31STEAMLINEA(SPING)AREA32STEAMLINEB(SPIHG)CVHYDROGENCONCENTRATION CVBASEHEHTLVL6FTTENP¹3CVINTERMEDIATE LVL6FTTEMP¹7CVINTERMEDIATE LVL6FTTEMP¹8CVINTERMEDIATE LVL6FTTEMP¹9CVINTERHEDIATE LVL6FTTEHP¹10CVOPERATING LVL6FTTEMP¹171485.94.56.177.65.166.81.79.02214-02 7.35678+00 1.3994&001.29701+02 9.09354-01

1.0 9283i00

9.58719+01 5.18901+02 7.38002+02 4.30543t01 8.58327+01 4.22831+01 2.78658+03 1.19174+04 5.05861-01 5'9440.011.57835+03 1.89699-07 2.53990-02 3.57435-05 1.41261-03 4.40312-07 6.86543-05 3.72621-03 2.09411-07 1.34492-05 1.27941-03 2.33040+00 1.01048-02 .095.1106.0106.6106.7106.2117.5GOODG(XSGOODGOODGOtX)G(XX)GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOODGOODGOODGOODGOODGPMXMPHDEG.DEGFDEGFDEGFMR/HMR/HMR/MMR/HMR/HMR/HCPMCPHCPMCPMCPMCPHCPHCPHR/HRR/HRCPMUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRMR/HRXDEGFDEGFDEGFDEGFDEGFDEGF Time:~121Message:~4~INNATATIN12EVALATEDEXERIEMESSAEFORMT:NININSimulaePlanCondition: SeetheAttachedSheets~Messse:"""THISISANEXERCISE""" FORCONTROLLER USEONLY~CINAnticiaedResuls:1)Operators performing theApplicable ActionsofES-3.1(Post-SGTR CooldownUsingBackfill). 2)TSCevaluating Plantconditions andtakingactionasrequired. 3)EOFevaluating Plantconditions andtakingactionasrequired. 199K'VALUATED EXERCISEMAJORPARAMETERS ENGINEERED SAFEGUARDS A.RUNNINGUNLOADEDTOOSB.RUNNINGUNLOADEDSTBOOSTSCRUNNINGUNLOADEDTBOOSSecurityRUNNINGUNLOADEDTBENGINEERED SAFEGUARDS OOSAux.Feedwater Pums1A.INSERVTBOOS1B.SRSTBYOOSTurb.rivenINSERVBOOSCSTLevel/2F*CET=AverageofSelectedCoreReactorShutdownESNON-31CPSN-32~OCPSN-35NH/AMPSN-36AMPSAvg.NuclearPower0RCSPressurePSIGPRZRLevelARCPRGOPPEBRCPUNNINSTOPPED1AS/GLevel1BS/GLevel~E~to1AS/GPressurePSIG1BS/GPressurePSIGTurbine/Generator ONLINEFL4KVBusesERGIZEDEENERGIZED 480VBusesNERGIZEDDEENERGIZED DCBatteries A~SOVOLTS B~VOLTSCnmtPressure-~R.PSZGCnmtSumpALevel?.FEETCnmtSumpBLevelINCHESALoopHotLeg~Qg.dLOFALoopColdLegOFBLoopHotLegI.OFBLoopColdLeg~i.OOFRVLIS~K>~*CEToF'/GATotalAuxFWFlow~GPMS/GBTotalAuxFWFlow~fGPMDIESELGENERATORS HihHeadS.Z.PumsFI-924C)GPMFZ-925NGPM1AINSERVTBOOS1B.INSERVTBOOS1CINSERVTBOOSBASTLevel=/C7LowHeadS.Z.PumsFI-626OGPM1A.INSERVOOSRECIRC1'NSERVOOSRECIRCRWSTLevel=VS-Containment SraPumsFZ-931AGPMFI-931BC)GP1A.INSERVTOOS1B.INSERVOOSNaOHTankLevel=Containment ecircFans1A.ESTBYOOS1B.SESTBYOOS1C.SESTBYOOS1D.STBYOOSPostAccidentDampersENCLOSEDServiceWaterPums1A.INSEVSTBYOS1B.SESTBYOOS1C~SERSTBYOOS1D.NRSTBYOOSA&BHeaderressure~PSIGComonentCoolinWaterPums1A.IERVSTBYOOS1B.INSERVSTBYOOSSurgeTanvel=StandbAux.Feedwater Pums1C.INSERVTOOS1D.INSERVTBOOSExitThermocouples Gr199212:15R.E.GINASft(ULATOR TRENDGROUPASSIG)STSUM)IRYPA6E1GROUP:EVENTiPROCEDURE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION VALUEQUALE.U.1235678~9101112131415161718f9202122232425262728293031323334353637383940414243444546474849505152ATMSR)(TN31N32N35N36NPPRCSLPLRFRCLAFRCLBRXT16RXT17TSUBTCLSGRLS6BPSGAPSGBGEtlBKRlGENBKR2BUS11RBUS11BBUS12ABUS12BB11A12RB11812BPCVLSlNPAL0942EL0943EL0942DL0943DL0942CL0943CL0942BL0943BL0942AL0943AT0409RT0410RT0450T0451TAVGAMIDTR'LGBMID LRVTCCOREFAUXFMRFRUXFMBBKR081BKR082V3505V3504ANTICIPATED TRANSIENT M/0SCRAMREACTORTRIPBREAKERSTATUSSMKERANGEDETECTORN-31SISCERRt(GEDETECTORN-32INTERMEDIATE RAN6EDETECTORN-35INTERMEDIATE RANGEDETECTORN-36AVERA6ENUCLEARPOWERRECTORCOOLANTSYSTEMAVGPRESSPRESSURIZER AVERAGELEVELREACTORCOOLW(TLOOPAAVGFLOWREACTORCOOLANTLOOPBAVGFLOWRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCORETCSUBCOOLED MARGINSTMGENANARROMRANGEAVGLEVELSTMGENBNARROWRAKEAVGLEVELSTMGENAAVERAGEPRESSURESTMGENBAVERAGEPRESSUREGENERATOR ONLINEBREAKER161372GYRATORONLINEBREAKER9X1372BUS11ASUPPLYBREAKERBUS11BSUPPLYBREAKERNOTTERMIt(ATED ONPPCS(7/19/91) NOTTERMINATED ONPPCS(7/19/91) BUS11ATO12ATIEBREAKERBUS11BTO128TfEBREAKERCONTAINMENT AVERAGEPRESSURECO)1TAIt(MENT SUMPAAVERAGELEVELSU)A'LEVEL6INCHES(TRAINA)SUB'LEVEL8INCHES(TRAINB)SUtf'LEVEL78INOKS(TRAINA)SUtf'LEVEL78fNCHES(TRAINB)SUMPBLEVEL113INCHES(TRAIN A)SrJYP8LEVEL113INCHES(TRAIN B)SUMPBLEVEL180It(CHES(TRAIN A)SUtf'LEVEL180INCHES(TRRIN B)SUtfBLEVEL214INCHES(TRAIN A)SUtPBLEVEL214INCHES(TRAIN B)RCLRHOTLEGTEMPERATURE RCLBHOTLEGTEMPERATURE RCLRCOLDLEGTEMPERAT(RE RCLBCOLDLEGTEMPERRTNE RCLRTAVG(THOT!TCOLD WIDERNG)RCLBTAVG(T)GT/TCOLD WIDERNG)REACTORVESSELAVERAGELEVELEl.lft,ORETCAVERAGETEMPS/GRTOT&'UXFEEBtA7rZ FLOWS/GBTOTALAUXFEENATERFLOWMTRAUXILIARY FEEDMATER PUMPAMTRAUXILIARY FEEDMRTER PUMPBAUXFMPUt(PSTER)(SUPPLYVALVEARUXFMPUN'TEANSUPPLYVALVEBATMSRXTRIPPED8.55064+01 7.95241+01 1.01391"11 1~01391-11.00899.58.913.0114.0TRIPPEDNOTTRIP115.729.436.0919.268.TRfPPEDTRIPPEDTRIPPEDTRIPPEDNOTTRIPNOTTRIPNOTTRIPNOTTRIP-282.5LONERl.ONERLONERLONERLONERLONERLONERLONERLONERLONER418.9418.0416.2416.0417.5417.099.6417.70.189.OFFONCLOSEDCLOSEDRLRt(ALIIGOOD6000GOOD600DGOODGOODGOODINHBGOODALRt(600D600~LMRNGOODGOODLALt(RUIALR)(ALRtfAUIDELDELRLRt(AUI600DHMRNGOODGOODGOODGOOD600D60006009600D6000600DGOODGOODGOODGOODGOOD6000GOOD600>GOOD600D600D680DGOODGOODCPSCPSAMPAMPXPSIGXXXDEGFPSI6PSIGPSIGFKTDEGFKGFKGFKGFKGFK6FXKGFGPtfPM8'76 OCT8~199212:15R.E.GIWASINULATOR TRENDGROUPASSIGNNENT SUNNARYPAGE26ROUP:EVENT1PROCEDURES EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION VALUEQlALE.U.53545556'57585960EMJFSIASAFETYINJECTION:LOOP AFSIBSAFETYINJECTION LOOPBP2160SERVICEMATERPIIPSAhP2161SERVICEMATERPNPSChINR041SERVICEWATERPNPAIIR042SERVICEWATERPlNPBINR043SERVICEMATERPIIPCBKR044SERVICEMATERPNF0AVGFLOWAVGFLOWBHEADERDHEADER0.GOOD0.GOOD72.GOOD80.600DGOOD600D6009GOODGPN6PNPSIGPSIG ~~OGRAKNAHE:LRGTSZ.E R.E.GINNANUCLEARPOWERPLANTOCT08,9212:15:00TRENDGROUPASSIGNHEHT SUHHARYGROUPNAMEEVENT2GROUPDESCRIPTIOH PROCEDURE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURRENTVALUEQUALITYCODEEHGRUNITS12'456789101112131420212223242526272829,30313233343536373839404142430'0619LRWSTWS033WD033WT033WT250WOT2R01R02R05R09R34R35R10AR11R12R10BR13R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14A5R14A7R14A9R15ASR15A7R15A9R31R32CVHTCV03TCV07TCVOBTCV09TCV10TCV17COKPONEHT COOLINGLOOPTOTALFLWREFUELIHG WATERSTORAGETANKLVL33FOOTLEVELWINDSPEED33FOOTLEVELWINDDIRECTION 33FOOTLEVELTEMPERATURE 250FOOTLEVELTEHPERATURE 250TO33FOOTLEVELDELTATEHPAREA1-CONTROL ROOMAREA2-CONTAINMENT AREA5-SPENTFUELPITAREA9.LETDOWN LINEMONITORAREA34-AUXBLDGCVSPRAYPUMPAREA35-PASSSAMPLEPANELCONTAINMENT IODINEMONITORR10ACONTAINHENT AIRPARTICULATE COHTAINKENT GASMONITORPLANTVENTIODIHEMONITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASKOHITORLIQUIDWASTEDISPOSALMONITORSTEAMGENERATOR BLOWDOWNDRAINAREA29CONTAINHENT HIGHRANGEAREA30-COHTAINHEHT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5LOWRANGEGASCVVENTCHAN6-AREAGAHHACVVENTCHAH7MIDRANGEGASCVVENTCHAN9-HIGHRANGEGASPLANTVENTCHAN5-LOWRANGEGASPLANTVENTCHAN7-MIDRANGEGASPLANTVENTCHAN9-HIGHRANGEGASAIREJECTORCHANS-LOW RANGEGASAIREJECTORCHAN7-HIDRANGEGASAIREJECTORCHAN9-HlRANGEGASAREA31STEAKLIHEA(SPING)AREA32STEAHLINE8(SPING)CVHYDROGENCONCENTRATION CVBASEMENTLVL6FTTEHP¹3CVIHTERMEDIATE LVL6FTTEMP¹7CVINTERHEDIATE LVL6FTTEHP¹8CVINTERHEOIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEHP¹10CVOPERATING LVL6FTTEMP¹171485.94.56.577.66.067.81.89.02214-02 7.35678+00 1.39946+00 1.27501+02 9.09354-01 1.09283+00 9.58719+01 5.18901+02 7.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658i03 1.14174+04 5.05861.01 5.09440.01 1.57835+03 1.89699-07 2.53990-02 3.57435-05 141261-034.40312.07 6.86543-05 3.?2621-03 2.09411-07 1.34492-05 1.27941-032.25040t00 1.01048.02 .095~1106.0106.6106.7106.2117.5GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALHGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALHGOODGOODGOODGOODGOODGOODGOODGOODGPKXKPHOEG.DEGFDEGFDEGFMR/HMR/HKR/HKR/HKR/HKR/HCPHCPMCPMCPMCPMCPHCPKCPMR/NRR/HRCPHUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCKR/HRMR/HRDEGFDEGFDEGFDEGFDEGFDEGF Time:~12QMessage:~4GINNASTATION192EVALATEDEXERCISE~MEREEERRM~M:MIE<<IRSimulated PlantConditions: SeetheAttachedSheets~IVlessse:"""THISISANEXERCISE""" FORCONTROLLER USEONLYController Notes:1)Accidentevaluation andresponsecontinues. AnticiatedResuls:1)Recovery/Re-entry andDeclassification discussions shouldcommencepertheguidanceprovidedinEPIP3-4,"Emergency Declassification andRecovery." Discussions shouldalsoincludebutnotbelimitedtothefollowing: a)Preliminary discussions betweentheEOFandtheTSConthefollowing: ~ShortTermPlantconcernssuchas:1.2.3.4.5.Cooldownanddepressurization ofthePlant.Repairandreturntoserviceofthe"A"CCWPumptoensurearedundant pumpfordecayheatremoval.Repairandreturntoserviceofthe"A"ServiceWaterPump.RepairandreturntoserviceoftheNaturalGaslinetotheScreenhouse. Continued evaluation ofthedrilledholeinthe"B"S/GARV.(continued onthenextpage)

~Intermediate TermPlantconcernssuchas:1."A"S/GTubeinspection andrepair.2.Possible"B"S/GTubeinspection. 3.Radiological releasecalculations andevaluation. b)Preliminary designation oftheRecoveryOrganization. c)StateandcountiesmayalsoconductparallelRecovery/Re-entry discussions. 2)Recovery/Re-entry interface betweentheEOF/TSCandoffsiteagenciesshouldbedemonstrated astimeallows. 199'VALUATED EXERCISETime:~23G'AJOR PARAMETERS ENGINEERED SAFEGUARDS A.RUNNINGUNLOADEDTBOOSB.RUNNINGUNLOADEDTBOOSTSCRUNNINGUNLOADEDTBOOSSecurityRUNNINGUNLOADEDTENGINEERED SAFEGUARDS OOSAux.Feedwater Pums1A.INSERVTOOS1B.SESTBYOOSTurb.DrivenINSERVTBOOSCSTLevel~1FEETReactorShutdown(YYENON-31~CICPSN-32~~CPSN-35z~/AMPSN-36~-s/AMPSAvg.NuclearPowerC7RCSPressure~FE-PSTGPRZRLevelb~~l.ARCPRUNNINGTOPPEDBRCP~RUNNINSTOPPED1AS/GLevel1BS/GLevelS7.71AS/GPressurePSIG1BS/GPressure2.93PSIGTurbine/Generator ONLINEFFLI4KVBusesNERGIZEDEENERGIZED 480VBusesRDEENERGIZED DCBatteries A/BOVOLTSB/30VOLTSCnmtPressure~~30PSIGCnmtSumpALevel2,ekFEETCnmtSumpBLevel~~INCHESALoopHotLegBm.~oFALoopColdLeg~axaOFBLoopHotLeg.2OFBLoopColdLeg~oa.OFRVLISg54*CET~OS~0FS/GATotalAuxFWFlow0GPMS/GBTotalAuxFWFlowIa.aGPMDIESELGENERATORS HihHeadS.X.PumsFI-9240GPMFI-925&GPM1A.INSERVTBOOS1B.INSERVTBOOS1C.INSERVTBOOSBASTLevel=IoLowHeadS.I.PumsFI-626OGPM1A.INSERVOOSRECIRC1B.INSERVTBOOSRECIRCRWSTLevel=~E.VContainment SraPumsFI-931A&GPMFI-931BOGPM1A.INSERVTBOOS1B.INSERVTBOOSNaOHTankLevel=Containment RecircFans1A.NSEVSTBYOOS1B.SERSTBYOOS1C.SESTBYOOS1D.NSERSTBYOOSPostAccidentDampersECLOSEDServiceWaterPums1A.XNSERVSTBY01B.SESTBYOOS1C.NSERSTBYOOS1D~NSERSTBYOOSA&BHeaderPressure~7'0PSIGComonentCoolinWaterPums1A.INSERVSTBY001B.NSESTBYOOSSurgeTanevel=M/StandbAux.Feedwater Pums1C.INSERVTBOOS1D.INSERVSTBOOS*CET=AverageofSelectedCoreExit.Thermocouples 8sf99212:30R.E.GINASIMULATOR PAGE1=-TRENDGROUP-ASSIGNMENT SUMMARY6ROUP:EVENT1PROCEDURES EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION VALUE()UALE.U.12367891011121315161718192021222324252627282930313233343536373839404142434546474849505152ATMSRXTN31N32N35N36NPPRCSLP2RFRYFRMRXT16RXT17TSUBTCLSGALSGBPSGAPSGBGENBKRIGEt(BKR2BUS11ABUS11BBUS12ABUS12BBiiA12AB11812BPCVLQNPAL0942EL0943EL0942DL0943DL0942CL0943CL0942BL0943BL0942AL0943AT0409AT0410AT0450T0451TAVGAMIDTAVGBMIDLRVTCCOREFAUXFMAFAUXFWBBKR081BKR082V3505V3504ANTICIPATED TRANSIENT W/0SCRAMREACTORTRIPBREAKERSTATUSSOlRCERANGEDETECTORN-31SmSCERA)IGEDETECTORN-32INTERMEDIATE RANEEDETECTORN-35INTERMEDIATE RANGEDETECTORN-36AVERAGENLQZ8POWERREACTORCOOLANTSYSTEMAVGPRESSPRESSURI2ER AVERAGELEVELREKTORCOOLANTLOOPAAVGFLOWREKTORCOOLANTLOOPBAVGFLOWRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCORETCSUBC(mLED MARGINSTMGENANARROWRANGEAVGLEVELSTMGBIBNARROWRA%EAVGLEVELSTMGENAAVERAGEPRESSURESTMGEN8AVERAGEPRESSUREGBHNTORONLINEBREAKER161372GBERATORONLINEBREAKER9X1372BUS1fASUPPLYBREAKERBUS11BSlFPLYBREAKERNOTTERMIt(ATED OttPPCS(7/f9/91) NOTTERMIt(ATED ONPPCS(7/19/91) BUSifATo12ATfEBREAKERBUS11BTo128TIEBRENERCONMINMEt(T AVERAGEPRESSURECONTAINMENT SUMPAAVERAGELEVELSU)PBLEVEL8INCHES(TRAINA)SU)PBLEVEL8INCHES(TRAIt4B)SU)PBLEVEL78INCIIES(TRAINA)SU)PBLEVEL78INQKS(TRAINB)SU)PBLEVEL113INCHES(TRAIN A)SU)PBLEVEL113INCHES(TRAIN B)SU)PBLEVEL180INCHES(TRAIN A)SUIPBLEVEL180INCHES(TRAIN B)SU)PBLEVEL214INCHES(TRAIN A)SU)PBLEVEL214INCHES(TRAIN B)RCLAHOTLEGTEMPERATURE RCLBHOTLEGTEMPERATUR" RCLACOLDLEGTEtIPERATURE RCLBCOLDLEGTBIPERATNE RCLATAVG(THOT/TCOLD WIDERNG)RCLBTAVG(THOT/TCOI.D WIDERNG)REACTORVESSELAVERAGELEVELEi~1INCORETCAVERAGETEMPS/GATOTALAUXFEEDMATER FLOWS/GBTOTALAUXFEEDMATER FLOWMTRAUXILIARY FEEDMATER PUMPAMTRAUXILIARY FEEDMATER PUMPBAUXFMPUMPSTEANSUPPLYVALVEAAUXFWPUMPSTEANSUPPLYVALVEBATWSR)(TRIPPED7.95241+01 8.46249+01 1.01391-11 1.01391-11 .00892.61.813.2115.2TRIPPEDNOTTRIP128.621.751.7891.233.TRIPPEDTRIPPEDTRIPPEDTRIPPEDNOTTRIPNOTTRIPNOTTRIPt40TTRIP-.302.6LONERLONERLONERLONERLONERLo)IERLo)4ERLOWERLOWERLONER403.8404.2402.5402.5403.2403.499.5403.60.125.OFFONCLOSEDCLOSEDALRNALRN6009CPSGOODCPS6009AMP6009AMPGOODXGOODPSIGHMRNXINHBX6009XALRNGOOD600~DEGFLMRNXGOODX6009PSIGLALMPSIGALRNALRNALRNALRNDELDELALRNALRN6009PSIGHMRNFKf6009600960096009600960096009G0096009GOOD6009DEGF6009DEGF6009DEGFGOODDEGF6009DE6F600DDEGFGOODX600~DEGF6009GPMGOODGPM6009GOOD6009GOOD OCT8~1992,12!30R.E.GIt5ASIIIULATOR TRENDGROUPASSIGIDIENT SINNRYPAGE253FSIA54FSIB55P216056P216157BKR04158BKR04259BKR04360BKR044SAFETYINJECTION'LOOP ASAFETYINJECTION LOOPBSERVICEWATERPINPSAhSERVICEMATERPNIPSC5SEINICEWATERPINPASERVICEWATERPUlIPBSERVICEWATERPINPCSERVICEMATERPNP0GROUP:EVEIIT1PROCEDURE: POINTIDDESCRIPTION EPIP1-5PLNTSTATUSVALUEAVGFLOW0.AV6FLOW0.BHEADER72.DHEADER80.QUALE.U.GOOD6PtIGOOD6PNGOODPSIG600DPSIGGOOD600DGOOD600D ROGRAMNAME:LRGTSZ.E ~~~R.E.GIHHANUCLEARPOWERPLANTOCT08,9212:30:00TREHDGROUPASSIGNMEHT SUMMARYGROUPNAMEEVENT2GROUPDESCRIPTION PROCEDURE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURRENTVALUEQUALITYCODEENGRUNITS1234567891011121314192021222324252627282930313233343536373839404142430JF0619LRWSTWS033WD033WT033,WT250WDT2R01R02R05R09R34R35R10AR11R12R108R13R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14A5R14A7R14A9R15ASR15A7R15A9R31R32CVHTCV03TCV07TCVOBTCV09TCV10TCV17COMPONENT COOLINGLOOPTOTALFLWREFUELIHG WATERSTORAGETANKLVL33FOOTLEVELWINDSPEED33FOOTLEVEL'WIHDDIRECTION 33FOOTLEVELTEMPERATURE 250FOOTLEVELTEMPERATURE 250TO33FOOTLEVELDELTATEMPAREA1-CONTROL ROOMAREA2-CONTAIHMENT AREA5-SPENTFUELPITAREA9-LETDOWN LINEMONITORAREA34-AUXBLDGCVSPRAYPUMPAREA35PASSSAMPLEPANELCONTAINMENT IODINEMONITORR10ACONTAINMENT AIRPARTICULATE CONTAINMEHT GASMOHITORPLANTVENTIODINEMOHITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIQUIDWASTEDISPOSALMONITORSTEAMGENERATOR BLOWDOWHDRAINAREA29-COHTAIHHEHT HIGHRANGEAREA30-CONTAINMEHT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LOWRANGEGASCVVENTCHAN6-AREAGAMMACVVENTCHAN7-MIDRANGEGASCVVENTCHAN9-HIGHRANGEGASPLANTVENTCHAH5-LOWRANGEGASPLANTVENTCHAN7-MIDRANGEGASPLANTVENTCHAH9-HIGHRANGEGASAIREJECTORCHAN5-LOWRANGEGASAIREJECTORCHAN7-MIDRANGEGASAIREJECTORCHAN9HIRANGEGASAREA31STEAMLINEA(SPING)AREA32STEAMLINE8(SPIHG)CVHYDROGENCONCENTRATION CVBASEMENTLVL6FTTEMP¹3CVINTERMEDIATE LVL6FTTEMP¹7CVINTERMEDIATE LVL6FTTEMP¹8CVINTERMEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEMP¹'IOCVOPERATING LVL6FTTEMP¹171485.94.58.567.69.067.81.89.02214-02 7.35678+00 1.39946+00 1.24701+02 9.09354-01 1.09283+00 9.58719+01 5'8901+027.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658+03 1.09474+04 5.05861-01 5.09440.01 1'7835+031.89699.07 2.53990-02 3.57435-05 1.41261-03 4.40312-07 6.86543-05 3.72621-03 2.09411-07 1.34492-05 1.27941-03 2.18040t001.01048-02 .095.1106.0106.6106.7106.2117.5GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOODGOODGOODGOODGOODGPMxMPHBEGSDEGFDEGFDEGFMR/HMR/HMR/HMR/HMR/HMR/HCPMCPMCPMCPMCPMCPMCPMCPMR/HRR/HRCPMUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRMR/HRxDEGFDEGFDEGFDEGFDEGFDEGF Time:~124Message:~gINNATATIN192EVALUATED EXERISE~MEBBAGEF~MI:BIIG<<IRSimulated PlantConditions: SeetheAttachedSheets~INssae:"""THISISANEXERCISE""" FORCONTROLLER USEONLYCnrllrN1)Accidentevaluation andresponsecontinues. AnticiatedResults:1)Recovery/Re-entry andDeclassification discussions shouldcommencepertheguidanceprovidedinEPIP3-4,"Emergency Declassification andRecovery." Discussions shouldalsoincludebutnotbelimitedtothefollowing: a)Preliminary discussion betweentheEOFandtheTSConthefollowing: ~ShorttermPlantconcernssuchas:1.2.3.Cooldownanddepressurization ofthePlant.Repairandreturnto.serviceofthe"A"CCWPumptoensurearedundant pumpfordecayheatremoval~Repairandreturntoserviceofthe"A"ServiceWaterPump.RepairandreturntoserviceoftheNaturalGaslinetotheScreenhouse. Note:Anevaluation ofthismayleadtoadiscussion nottoreturnNaturalGastotheScreenhouse. (continued onthenextpage) ~Intermediate termPlantconditions suchas:1.2.3.4,"A"S/GTubeinspection andrepair.Possible"B"S/GTubeinspection. "A"S/GTuberuptureevaluation forrootcause.Radiological releasecalculations andevaluation. b)Preliminary designation oftheRecoveryOrganization. c)StateandcountiesmayalsoconductparallelRecovery/Re-entry discussions. 2)Recovery/Re-entry interface betweentheEOF/TSCandoffsiteagenciesshouldbedemonstrated astimeallows. 199KEVALUATED EXERCISETime:1~/~MAJORPARAMETERS ENGINEERED SAFEGUARDS ReactorShutdownYENON-310CPSN-32gCPSN-35feb'-IfAMPSN-36glAMPSAvg.NuclearPowerRCSPressure47PSIGPRZRLeveldOARCPRUNNINGTOPPEBRCPRUNNINGSTOPPED1AS/GLevel1BS/GLevel~.21AS/GPressure~~~PSIG1BS/GPressurewozPSIGTurbine/Generator ONLINEFFLIN4KVBusesRGDEENERGIZED 480VBusesENERGIZEDEENERGIZED DCBatteries A~VOLTSB/30VOLTSCnmtPressure~~~aSSPSIGCnmtSumpALevel2.~CeFEET.CnmtSumpBLevel~(INCHESALoopHotLeg>9m.r7OFALoopColdLeg~Et.s.OFBLoopHotLeg~i.ELOFBLoopColdLeg~.IOFRVLIS*CETOFS/GATotalAuxFWFlowGPMS/GBTotalAuxFWFlow~GPMDIESELGENERATORS A.RUNNINGUNLOADEDTBOOSB.RUNNINGUNLOADEDTBOOSTSCRUNNINGUNLOADEDTOOSSecurityRUNNINGUNLOADEDTBOOSENGINEERED SAFEGUARDS HihHeadS.I.PumsFI-9240GPMFI-925GPM1A.INSERVTBOOS1B.INSERVTOOS1CINSERVTBOOSBASTLevel=/LowHeadS.I.PumsFI-626OGPM1A.INSERVTOOSRECIRC1B.INSERVTBOOSRECIRCRWSTLevel=~3.Containment SraPumsFI-931AGPMFI-931BOGPM1A.INSERV1B.INSERVTNaOHTankLevel=OOSOOSContainment ecircFans1A.NSERSTBYOOS1B.SERSTBYOOS1C.SERSTBYOOS1D.NSESTBYOOSPostAccidentDampersPENCLOSEDServiceWaterPums1A.INSERVSTBY1B.NSERSTBYOOS1C.SERVSTBYOOS1D.NSSTBYOOSA&BHeaderressure~0PSIGComonentCoolinWaterPums1A.INSERVSTBY001B.NSERVSTBYOOSSurgeTanLevel=~%StandbAux.FeeaterPums1C.INSERVTBOOS1D.INSERVTBOOSAux.Feedwater Pums1A.INSERVTBOOS1B.SERSTBYOOSTurb.DrivenINSERVTOOSCSTLevel~iFEET*CET=AverageofSelectedCoreExitThermocouples 8~199212:45R.E.Glt5ASIMULATOR TRENDGROUPASSIG)MENT SUM)(ARYPA6E1GROUP:EVENT1PROCEDURES EPIP1-5PLA)ITSTATUS12345678910111213141S161718192021222324252627282930313233343536373839404142434446474849505152POINTIDATWSRXTN31N32N35N36t(PPRCSLPZRFRCLAFRCLBRXT16RXT17TSUBTCLSGALSGBPSGAPSGBGENBKR1GENBKR2BUS11ABUS11BBUS12ABUS12BB11A12ABiiB12BPCVLSINPALO942ELO943ELO942DLO943DLO942CLO943CLO942BLO9438LO942ALO943ATO409ATO41OATO450TO451TAVGAWIDTAVGBMIDLRVTCCGREFAUXFWAFAUXFWBBKRO81BKR082V35OSV3504DESCRIPTION ANTICIPATED TRANSIENT W/0SCRAMREACTORTRIPBREAKERSTATUSSmSCERANGEDETECTORN-31SolSCERWGEDETECTORN-32INIEI(MEDIATE RANGEDETECTORN"35INTERMEDIATE RANGEDETECTORN-36AVERAGENIKLEARPONERREACTORCOOLANTSYSTEMAVGPRESSPRESSURIIER AVERAGELEVELREACTORCGOL@TLOOPAAVGFLOWREACTORCOOLANTLOOPBAVGFLOWRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCGRETCSUBCOOLED MARGINSTMGENAtQRROMRAt(GEAVGLEVELSTMGEt(BNARROWRANGEAVGLEVELSTMGENAAVERAGEPRESSURESTMGENBAVERAGEPRESS)REGEtGQTORONLINEBREAKER161372GESITORONLINEBREAKER9X1372BUS11ASUPPLYBREAKERBUS11BRFPLYBREAKERNGTTERMINATED OttPPCS(7/19/91) NOTTERMINATED ONPPCS(7/19/91) BUSiiATO12ATIEBREAKERBUS11BTO12BTIEBREAKERCONTAIeENT AVERAGEPRESSURECONTAINMENT SUt(PAAVERAGELE4ELSU)PBLEVEL8INCHES(TRAINA)SUtPBLEVEL8INCHES(TRAINB)SU)PBLEVEL78IN&KG(TRAINA)SU)PBLEVEL78INCHES(TRAINB)SU)PBLEVEL113INCHES(TRAIN A)SUtPBLEVEL113INCHES(TRAIN B)SU)PBLEVEL180INCHES(TRAIN A)SUtP0LEVEL180INCHES(TRAIN B)SU)PBLEVEL214INCHES(TRAIt< A)SU)P0LEVEL214INCHES(TRAIN B)RCLAHOTLEGTEMPERATURE RCLBHGTLEGTEMPERATURE RCLACol.DLEGTE)IPERATlRE RCLBCOLDLEGTE)IPERATISE RCU)TAVG(THOT/TCOLD WIDERNG)RCLBTAVG(THOT/TCOLD WIDERNG)RECTORVESSPAVERAGELEVELEi.iINCORETCAVERAGETEMPS/6ATOTALAUXFEEDWATER FLWS/G8TOTALAUXFEEDWATRFLOWMTRAUXILIARY FEEDWATER PU)IPAt(TRAUXILIARY FEEDWATER PUt(P0AUXFWPUIIPSTEA)ISUPPLYVALVEAAUXFMPUI(PSTEA)lSl)PPLYVALVEBVALUEATNSRXTRIPPED7.95241+01 8.5802M)1 1.01391-11 1~01391-11.00767.60.013.3116.0TRIPPEDNOTTRIP122.918.8S6.2768,202.TRIPPEDTRIPPEDTRIPPEDTRIPPEDNGTTRIPNOTTRIPNOTTRIPNOTTRIP-.342.6LONERLONERLONERLONERLONERLONERLONERLONERLONERLONER392.7392.9391.2391.1392.0392.099.3392.7O.86.OFFONCLOSEDCLOSEDALRIIALR)(GOOD600060006000GOOD6000HWRNINHB6000ALRN6000600iLMRtl60006009LAL)IALRNALRI(ALRt(ALRNDELDELALRNALRtf6009HWRI(6000GOOD60006000GOOD60006000600060096000GOOD6000GOOD6000GOOD60006000Goo'009600060096000GOOD6000E.U.CPSCPSAMPAt(P/PSI6I/y.DEGFXXPSIGPSIGPSI6FKTDEGFKGFDEGFDE6FDEGFKGFKGFIPMGPM OCT8~199212:45R.E.GINASIRLATORTRENDGROUPASSIGNNENT RNNRYPA6E2GROUP!EVENT1PROCEDURE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION 53FSIASAFETYINJECTION'LKP AAVGFLOW54FSIBSAFETYINJECTION LOOPBAVGFLIN55P2160SERVICEMATERPlIPSAhBHEADER56P2161SERVICEMATERPIIPSCh9HEADER57BKR041SERVICEMATERPlmPA58BKR042SERVICEWATERPSFB59BKR043SERVICEMATERPNPC60BKR044SERVICEMATERPlIPDOFFONONON0.0.72.80.OVALE.U.GOODGPNGOODIF'00DPSIGGOODPSIGGOODGOOD600DGOOD ROGRAMNAME:LRGTSZ~E~~R.E.GIHNANUCLEARPOWERPLANTOCT08,92124500TRENDGROUPASSIGNMENT SUMMARYGROUPNAMEEVENT2GROUPDESCRIPTIONPROCEDURE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURRENTVALUEDUALITYCODEENGRUNITS123456789101213142021222324252627282930313233343536373839404142430-F0619LRWSTWS033WD033WT033WT250WDT2R01R02R05R09R34R35R10AR11R12R108R13R14R18R19R29R30R15R12A5R12A6R12A7R12A9R14A5R14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03TCV07TCV08TCV09TCV10TCV17COMPONENT COOLIHGLOOPTOTALFLWREFUELING 'WATERSTORAGETANKLVL33FOOTLEVELWINDSPEED33FOOTLEVELWIHDDIRECTION 33FOOTLEVELTEMPERATURE 250FOOTLEVELTEMPERATURE 250TO33FOOTLEVELDELTATEMPAREA1-CONTROL ROOMAREA2-COHTAINMEHT AREA5-SPEHTFUELPITAREA9-LETDOWN LINEMONITORAREA34-AUXBLDGCVSPRAYPUMPAREA35-PASSSAMPLEPAHELCONTAINMEHT IODINEMONITORR10ACONTAINMENT AIRPARTICULATE CONTAINMENT GASMONITORPLANTVENTIODINEMONITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIQUIDWASTEDISPOSALMONITORSTEAMGENERATOR SLOWDOWNDRAINAREA29-COHTAINMEHT HIGHRANGEAREA30-CONTAINMENT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LOWRANGEGASCVVENTCHAN6-AREAGAMHACVVENTCHAN7-MIDRANGEGASCVVENTCHAN9-HIGHRAHGEGASPLANTVENTCHAN5-LOWRAHGEGASPLANI'ENT CHAN7MIDRAHGEGAS=PLANTVEHTCHAN9-HIGHRANGEGASAIREJECTORCHAH5-LOWRANGEGASAIREJECTORCHAN7-MIDRAHGEGASAIREJECTORCHAN9-MlRANGEGASAREA31STEAMLINEA(SPING)AREA32STEAMLINEB(SPING)CVHYDROGENCONCENTRATION CVBASEMENTLVL6FTTEMP¹3CVINTERMEDIATE LVL6FTTEMP¹7CVINTERMEDIATE LVL6FTTEMP¹8CVINTERMEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEMP¹10CVOPERATING LVL6FTTEHP¹171485~94.58.765.66.067.81.89.02214-02 7.35678+00 1.39946+00 1~22501+029.09354-01

1.0 9283i00

9.58719+01 5'8901+027.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658+03 1.02474+04 5.05861-01 5.09440.01 1.57835+03 1.89699-07 2'3990.023.57435-05 1.41261-03 4.40312-07 6.86543-05 3.72621-03 2.09411-07 1.34492-05 1.27941.032.16040+001.01048-02 ~095.1106.0106.6106.7106.2117.5GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODBALMGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOODGOODGOODGOODGOODGPMxMPHDEG.DEGFDEGFDEGFMR/HMR/HMR/HMR/HMR/HMR/HCPMCPMCPMCPMCPMCPMCPMCPMR/HRR/HRCPMUCI/CCMR/NRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/NRMR/NRXDEGFDEGFDEGFDEGFDEGFDEGF Time:~1QQMessage:~1INNATATION12EVALUATED EXERIEIVIESAEFRMI:CI<<C<<IRSimulated PlanConditions: SeetheAttachedSheetsM~esacaS:"""THISISANEXERCISE""" FORCONTROLLER USEONLY~CIIR1)Accidentevaluation andresponsecontinues. AnticiaedResults;1)Recovery/Re-entry anddeclassification discussions shouldcommencepertheguidanceprovidedinEPIP3-4,"Emergency Declassification andRecovery." Discussions shouldalsoincludebutnotbelimitedtothefollowing; a)Preliminary discussions betweentheEOFandtheTSConthefollowing: ~ShorttermPlantconcernssuchas:1.2.3.4.Cooldownanddepressurization ofthePlant.Repairand-return toserviceofthe"A"CCWPumptoensurearedundant pumpfordecayheatremoval.Repairandreturntoserviceofthe"A"ServiceWaterPump.RepairandreturntoserviceoftheNaturalGaslinetotheScreenhouse. Note:Anevaluation ofthiseventmayleadtoadiscussion nottoreturnNaturalGastotheScreenhouse, (continued onnextpage) 5.Continued evaluation ofthedrilledholeinthe"B"S/GARV.~Intermediate termPlantconditions suchas:1.2.3.4."A"S/GTubeinspection andrepair.Possible"B"S/GTubeinspection. "A"S/GTuberuptureevaluation forrootcause.Radiological releasecalculations andevaluation. b)Preliminary designation oftheRecoveryOrganization. c)StateandcountiesmayalsoconductparallelRecovery/Re-entry discussions. 2)Recovery/Re-entry interface betweenEOF/TSCandoffsiteagenciesshouldbedemonstrated astimeallows. 199PEVALUATED EXERCISETime:ISO'AZORP20&METERS ENGINEERED SAFEGUARDS HihHeadS.I.PumsFI-924NGPMFI-925~GPM1AINSERVTBOOS1B.INSERVBOOS1CINSERVTBOOSBASTLevel=~1LowHeadS.I.PumsFI-626OGPM1A.INSERVTBOOSRECIRC1B.INSERVTBOOSRECIRCRWSTLevel=3.Containment SraPumsFI-931AOGPMFI-931B&GPM1A.INSERVTOOS1B.INSERVTBOOSNaOHTankLevel='FContainment RecircFanslA.SESTBYOOS1B.SESTBYOOS1C.NSESTBYOOS1D.NSERSTBYOOSPostAccidentDampersPENCLOSEDServiceWaterPums1A.INRVSTBY01B.NSESTBYOOS1C.ERSTBYOOS1D.NSERVSTBYOOSA&BHeaderPressure7~'0PSIGDIESELGENERATORS A.RUNNINGUNLOADEDTBOOSB.RUNNINGUNLOADEDTBOOSTSCRUNNINGUNLOADEDTBOOSSecurityRUNNINGUNLOADEDTBOOSComonentCoolinWaterPumsReactorShutdownENON-31CPSN-32~CPSN-35-s(AMPSN-36AMPSAvg.NuclearPower0RCSPressure~@iPSIGPRZRLevel3).aARCPRUNNINGTOPPBRCPUNNINSTOPPED1AS/GLevel27.11BS/GLevel1AS/GPressurePSIG1BS/GPressurel7PSIGTurbine/Generator ONLINEFFLI4KVBusesNERGIZEDDEERGIZED480VBusesNERGIEDEENERGIZED DCBatteries AI3oVOLTSBI30VOLTSCnmtPressure3'SIGCnmtSumpALevel2.7FEETCnmtSumpBLevel~(INCHESALoopHotLeg~SPOOFALoopColdLeg~3I70F.BLoopHotLegOFBLoopColdLeg3t/.sOFRVLIS'~/*CET~~..9'FS/GATotalAuxFWFlowGPMS/GBTotalAuxFWFlowaGPMENGINEERED SAFEGUARDS Aux.Feedwater Pums1A.NSESTBYOOS1B.NSERSTBYOOSTurb.DrivenINSERVTBOOS1A.INSSTBY01B.NSERSTBYOOSSurgeTanLevel=~i~4StandbAux.FewaterPums1C.INSERVSTBOOS1D.INSERVSTBOOSCSTLevel~/F*CET=AverageofSelectedCoreExitThermocouples Gs199213:00R.E.GINASltmLATOR PAGE1TRENDGROUP*ASSIGN)(Et(T SU)IARYGROUP!EVENT1PRXED(IE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION E.U.12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152ATl6RXTN31N32N35N36NPPRCSLPLRFRCLAFRCLBRXT16RXT17TSUBTCLSGALSGBPSGAPSGBGENBKRlGBIKR2BUSllABUS11BBUS12ABUS12BBllA12AB11B129PCVLS(IPAL0942EL0943EL0942DL0943DL0942CL0943CL0942BL0943BL0942AL0943AT0409AT0410AT0450T0451TAVGAMIDTAVGBWIDLRVTCCOREFAUXFMAFAUXFMBBKR081BKR082V3505V3504ANTICIPATED TRANSIENT M/0SCRNREACTORTRIPBREAKERSTATUSSmmCERANGEDETECTORN-31SmnCERA%EDETECTORN-32INTERNEDIATE RANGEKfECTORN-35INTERNEDIATE RANGEDETECTORN-36AVERAGENLQZ8POMERREACTORCOOLANTSYSTB(AVGPRESSPRESSURIlER AVERAGELEVELREACTORCOOLNTLOOPAAVGFLOMREACTORCOOLNI'OOP BAVGFLOMRCPABRENERCAUSERXTRIPRCPBBREAKERCAUSERXTRIPINCORETCSUBCOOLED t(ARGINSTtt6BlANARROMRA%EAVGLEVELSTNGENBNARROMRAtlGEAVGLEVELSTt(GB(AAVERAGEPRESSURESTNGENBAVERAGEPRESSUREGEtGQTORONLINEBREAKER161372GENERATOR ONLINEBRENER9Xf372BUS11ASLPPLYBREAKERBUS11BSUPPLYBREAKERNOTTERNINATED OttPPCS(7/19/91) tloTTERt(lt(ATED ONPPCS(7/19/91) BUS11ATO12ATIEBREAKERBUS11BTo12BTIEBREAKERCONTAINtiENT AVERAGEPRESSURECONTAItlt(B(T PJt(PAAVERAGELEVELSIPBLEVEL8INCHES(TRAINA)SUtPBLEVEL8It(CHES(TRAIN9)SU)PBLEVEL78INCHES(TRAINA)SU)PBLEVEL78IN&KG(TRAINB)SUtPBLEVEL113INCHES(TRAIN A)SU)PBLEVEL113INCHES(TRAIN B)SU)PBLEVEL180INCHES(TRAIN A)SU)P8LEVEL180INCHES(TRAIN B)SUtPBLEAL214INCHES(TRAIN A)SU)PBLEVEL214INCHES(TRAIN B)RCLAHOTLEGTB(PERATUfK RCLBHOTLEGTEt(PERATURE RCLACOLDLEGTB(PERATNE RCLBCOLDLEGTB(PERAT(RE RCLATAVG(THOT/TCOLD MIDERNG)RCLBTAVG(THOT/TCOLD MIDERNG)REI:TORVESSELAVERAGELEVELEl~1INCORETCAVERAGETBPS/6ATOTALAUXFEEDMATER FLOMS/GBTOTALAUXFEEDMATER FLONNTRAUXILIARY FEEDMATER PUt(PAt(TRAUXILIARY FEEDMATER PUlPBAUXFMPUttPSTEANSUPPLYVALVEAAUXFMPU!PSTBISUPPLYVALVEB'IRXTRIPPED8.40424+01 8.60992+01 1.01391-11 1.01391-11 F00646,31.513.5116.7TRIPPEDNOTTRIP113.228.755.4615.174.TRIPPEDTRIPPEDTRIPPEDTRIPPEDNOTTRIPNOTTRIPNOTTRIPNOTTRIP-.362.7LONERLONERLONERLONERLONERLONERLONERLONERLONERLONER385.9383.7381.7381.5383.8382.699.1'382.953I24.ONONCLOSEDCLOSEDGoon60096009600D6009GOOD6009INHH6009ALRt(6009600~LMRttGoon6009LALNAUIALRt(6009GOOD60096009GOOD6009GoonGOODGOODGOOD600DGoon6009600960096009GOOD600~6009GOOD60096009GoonCPSCPSI(PAl(P0/PSIGXy.7DEGFX/PSIGPSIGDEGFD""BFDEGFDEGFIEGFDEGFXDE6FGPt(GPt(w-AD%3 OCT8~199213l00R.E.GINASIMULATOR TRENDGROUPASSIGNMENT SUMMARYPAGE26ROUP:EVENTIPROCEDURE: EPIP1-5PLAtITSTATUSPOINTIDDESCRIPTION VALUEQUALE.U.53FSIA54FSIB55P216056P216157BNR04158ImR04259BKR04360IIR044E+JSAFETYINJECTION'LOOP AAVGFLOWSAFETYINJECTION LOOPBAVGFLOWSERVICEWATERPNFSAhBHEADERSERVICEWATERPNFSChDHEADERSERVICEWATERPNFASERVICEWATERPNFBSERVICEWATERPNFCSERVICEWATERPNFDOFFONONON0.0.72.80.GOODGPMGOODGPM600DPSIGGOODPSI6GOODGOOD600DGOOD ROGRAHNAHE:LRGTSZ.E R.E.GINNANUCLEARPOWERPLANTOCT08,9213:01:00TRENDGROUPASSIGNHENT SUMHARYGROUPNAHEEVEHT2GROUPDESCRIPTION PROCEDURE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURRENTVALUEDUALITYCODEENGRUNITS1234567891011121314192021222324252627282930313233343536373839404142430JF0619LRWSTWS033W0033WT033WT250WDT2R01R02R05R09R34R35R10AR11R12R108R13R14R18R19R29R30R15R12ASR12A6R12A7R12A9R14A5R14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03TCV07TCV08TCV09TCV10TCV17COMPONENT COOLINGLOOPTOTALFLWREFUELING 'WATERSTORAGETANKLVL33FOOTLEVELWIHDSPEED33FOOTLEVELWINDDIRECTION 33FOOTLEVELTEHPERATURE 250FOOTLEVELTEHPERATURE 250TO33FOOTLEVELDELTATEHPAREA1-CONTROL ROOMAREA2-COHTAINHENT AREA5-SPENTFUELPITAREA9-LETDOWN LINEMONITORAREA34-AUXBLDGCVSPRAYPUMPAREA35-PASSSAMPLEPANELCONTAINMENT IODINEMONITORR10ACOHTAINHENT AIRPARTICULATE CONTAINHENT GASMONITORPLANTVENI'OOIHE MOHITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASMONITORLIQUIDWASTEDISPOSALHONITORSTEAMGENERATOR BLOWDOWNDRAINAREA'9.CONTAINHEHT HIGHRANGEAREA30-CONTAINHENT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LOWRANGEGASCVVENTCHAN6-AREAGAMMACVVENTCHAN7-HIDRANGEGASCVVENTCHAN9-HIGHRANGEGASPLANTVENTCHAN5-LOWRANGEGASPLANTVENTCHAN7-MIDRANGEGASPLANTVENTCHAN9.HIGHRAHGEGASAIREJECTORCHAN5-LOWRANGEGASAIREJECTORCHAN7.MIDRANGEGASAIREJECTORCHAN9-HIRANGEGASAREA31STEAMLINEA(SPING)AREA32STEAMLINEB(SPING)CVHYDROGENCONCENTRATION CVBASEMENTLVL6FTTEHP¹3CVINTERHEDIATE LVL6FTTEHP¹7CVINTERMEDIATE LVL6FTTEHP¹8CVINTERMEDIATE LVL6FTTEMP¹9CVINTERMEDIATE LVL6FTTEHP¹10CVOPERATING LVL6FTTEHP¹171485.94.58.765.66.067.81.89.02214-02 7.35678+00 1.3994&001.20701+02 9.09354-01 1.09283+00 9.58719+01 5.18901+02 7.38002+02 4.30543+01 8.58327+01 4.22831+012.78658+03 9.90174+03 5'5861-015.09440-01 1.57835+03 1.89699-07 2.53990-02 3.57435-05 1.41261-03 4.40312.07 6.86543.05 3.72621-03 2.09411-07 1.34492-05 1.27941-03 1.93040+00 1.01048.02 .095.1106.0106.6106.7106.2117.5GOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOGOKALMGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALHGOODGOODGOODGOODGOODGOODGOODGOODGPHxMPHDEG.DEGFDEGFDEGFMR/HMR/HMR/HMR/HMR/HHR/HCPMCPHCPHCPMCPHCPHCPMCPMR/HRR/HRCPMUCI/CCMR/HRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/HRHR/HRDEGFDEGFDEGFDEGFDEGFDEGF Time:~1~1Message:~2SIINNAATATI~1992EVALUATED EXERCIEMESSAGEFORM~NI:8I<<NNASimulaedPlanCondiions:SeetheAttachedSheets~Messse:"""THISISANEXERCISE""" TheExerciseisTerminated. FORCONTROLLER USEONLYController Notes:1)DeliverwhenallExerciseobjectives havebeendemonstrated. AnticiatedResults:1)Closeoutbymakinganannouncement toallfacilities (including REGS)thattheExerciseisterminated. 199PEVALUATED EXERCISETime:I3l~MAJORPARAMETERS ENGINEERED SAFEGUARDS ReactorShutdownN-31N-32N-35N-36Avg.NuclearPowerRCSPressurePRZRLevelARCPBRCP1AS/GLevel1BS/GLevel1AS/GPressure1BS/GPressureTurbine/Generator 4KVBuses480VBusesDCBatteries A/SbCnmtPressureCnmtSumpALevelCnmtSumpBLevelALoopHotLegALoopColdLegBLoopHotLegBLoopColdLegRVLIS*CETS/GATotalAuxFWS/GBTotalAuxFWDIESELGENERATORS ESNO~~CPS~OCPSg.OE-IIAMPSAss'->IAMPs$3OPSIG&RUNNINGTOPPUNNINSTOPPED~s.o&~~PSIG/z.(rPSIGONLINEFFLINERGIZEDEENERGIZED ERGIZEDEENERGIZED VOLTSB/B~'VOLTS -.3gPSIG2..7FEET~(INCHESOFSS2.OF3'F/ST'FOFV$"9'FFlow88GPMFlow2-9GPMOOSA.RUNNINGUNLOADEDTBOOSB.RUNNINGUNLOADEDTBOOSTSCRUNNINGUNLOADEDTBOOSSecurityRUNNINGUNLOADEDENGINEERED SAFEGUARDS HihHeadS.I.PumsFI-924OGPMFI-925C)GPM1A.INSERVTOOS1B.INSERVTOOS1C.INSERVBOOSBASTLevel=/OLowHeadS.I.PumsFI-626GPM1A.INSERVOOSRECIRC1B.INSERVTBOOSRECIRCRWSTLevel=9'3.Containment SraPumsFI-931AGPMFI-931BNGPM1A.INSERVTOOS1B.INSERVTBOOSNaOHTankLevel=Containme ecircFans1A.SERVSTBYOOSostAccidentDampersServiceWaterPums1A.INSEVSTBYOS1B.NSRSTBYOOS1C.NSERVSTBYOOS1D.NSERSTBYOOSA&BHeaderPressureV~0PSIGComonentCoolinWaterPums1A.INSERVSTBY01B.NSERVSTBYOOSSurgeTauLevel=~d1B.SERVSTBYOOSlc.SESTBYOOS1D.NSERVSTBYOOSPOPECLOSEDStandbAux.Feedwater Pums1C.INSERVSTBOOS1D.INSERVTBOOSAux.Feedwater Pums1A.SESTBYOOS1B.NSESTBYOOSTurb.DrivenINSERVTBOOSCSTLevel~FET*CET=AverageofSelectedCoreExitThermocouples

81199213:16R.E.GINASft(ULATOR TRENDGROUPASSIGN>(Et(T SUI(ARYPAGE1GROUP:EVENT1PROCEDURE: EPIP1"5PLANTSTATUSPOINTIDDESCRIPTION E.U.123456789101112131415161718202122232425262728293031323334353637383940414243444546474849505152ATWSRXTN31N32N35tG6NPPRCSLPLRFRCLAFRCLBRXT16RXT17TSUBTCLSGALSGBPSGAPSGBBBSKRIGBSKR2BUS11ABUS118BUS12ABUS12BB11A12AB11B12BPCVLSiNPAL0942EL0943EL0942DL09439L0942CL0943CL0942BL0943BL0942AL0943AT0409AT0410AT0450T0451TAVGAWIDTAVGBWfDLRVTCCOREFAUXFWAFAUXFWBBKRO81BKR082V3505V3504ANTICIPATED TRANSIENT W/0SCRNREACTORTRIPBREAKERSTATUSSolsCERANGEDETECTORN-31So(ICERANGEDETECTORN-32INTERt(EDIATE RANGEDETECTORN-35It(TER>(EDIATE RANGEDETECTORN-36AVERAGENUCLEARPOWERREACTORCOOLANTSYSTEtlAVGPRESSPRESSURIIER AVERAGELEVELRECTORCOKAVTLOOPAAVGFLOWREI:TORCOOLW(TLOOPBAVGFLOWRCPABREAKERCAUSERXTRIPRCPBBREAKERCAUSERX'IHIPINCORETCSUBCOOLED t(ARGINSTt(GEttANARROWRANGEAVGLEVELSTNGENBNARROWRANGEAVGLEVELSTt(GEt(AAVERAGEPRESSURESTt(GENBAVERAGEPRESSUREGBERATORONLINEBREAKER161372GBERATORONLINEBREAKER9X1372BUS11ASUPPLYBS(ERBUSliBSliPPLYBREAKERt(OTTERt)lt(ATEDONPPCS(7/19/91) NOTTERNINATED ONPPCS(7/19/91) BUS11ATO12ATIEBRENERBUS11BTO12BTfEBREA((ERCONTAIN)(ENT AVERAGEPRESSURECot(TAIttt(EtIT SUt(PAAVERAGELEVELSiRPBLEVEL8INCHES(TRAINA)SUtPBLEVEL8INCHES(TRAIN9)SU>PBLEVEL78INCHES(TRAINA)SU)PBLEVEL78INC)XS(TRAINB>SU>PBLEVEL113INCHES(TRAIN A)SU)PBLEVEL113INCHES(TRAIN B)SU)PBLEVEL180INCHES(TRAIN A>SU)PBLEVEL180INCHES(TRAIN B)SIPBLEVEL214INCHES(TRAIN A)SU>PBLEVEL214INCHES(TRAIN B)RCLAHOTLEGTEt)PERATUR= RCLBHOTLEGTEt(PERATUfK RCLACOLDLEGTPiPERAT(HE RCLBCOLDLEGTEt(PERAT(SE RCLATAVG(THOT/TCOLD WIDERNG)RCLBTAVG(THOT/TCOLD WIDERNG)REACTORVESSELAVERAGELEVELEl.1INCORETCAVERAGETEt(PS/GATOTALAUXFEEDWATER FL(IS/GBTOTALAUXFEENA7RFLOWt(TRAUXILIARY FEEDWATER PUt(PAt(TRAUXILIARY FEEDWATER PUt(P9AUXFNPlNPSTEA)fSUPPLYVALVEAAUXFWPUt(PSTEAtfSUPPLYVALVEBATWSRXTRIPPED8.40424+01 8.03523+01 I.Oi39f-ff 1.01391"ii .00530.32.413,6118.6TRIPPEDNOTTRIP116.530.034.4525.126.TRIPPEDTRfPPEDTRIPPEDTRfPPEDNOTTRIPNOTTRIPNOTTRIPNOTTRIP-.382.7LONERLONERLONERLONERLONER/ONERLONERLONERLONERLONER360.3359.8358.2357.9359.3358.998.9359.455.23.ONONCLOSEDCLOSEDALfmALRt(600960096009GOOD600960096009INHB6009ALR)(6009600~LWRNGoonLWfiLALNALRt(ALRtjALRtlALRt(DELDELALfmALRt{6009HWRt(Goon6009600960096009Goon6009Goon6009600960096009Goon6009GOOD6009Goo>GOOD6009600960096009CPSCPSNPAt(PPSIGXXDEGFXPSIGPSIGPSIGFFEfDEGFKGFDEGFDEGFDEGFDEGFXDEGFGP>(8't( XT8~199213:ibR.E.GINASINULATOR ---TRENDGMlUPASSIGNBtT StNMYPAGE26tm'VENTi PROCES'PIP 1-5PLANTSTATUSPOINTIDDESCRIPTION VALUENNLE.U.53FSIA54FSIB55P216056P2161'57Bt<R04158IaR04259BttR04360BttR044SAFETYINJECTION LOOPASAFETYINJECTION LOOPBSERVICEWATERPtNPSA5SERVICEWATERPtNPSChSERVICEWATERPtNPASERVICEWATERPUtPBSERVICEWATERPtNPCSERVICEWATERPtNP0AV6FLOWAVGFLOWBHEADERDHEAXROFFONONON0.600D0.600D72.600DSo.GOOD600D600D600D600DfPttGPNPSIGPSIGE+J ROGRAMNAME:LRGTSZ.E R.E.GINHANUCLEARPONERPLANTOCT08,9213:14:00TRENDGROUPASSIGNHENT SUMMARYGROUPHAMEEVENT2GROUPDESCRIPTION PROCEDURE: EPIP1-5PLANTSTATUSPOINTIDDESCRIPTION CURRENTVALUEQUALITYCODEENGRUNITS123456789101112131920212223242526272829303132333435363738394041423F0619LRNSTWS033ll0033UT033IH250WDT2R01R02R05R09R34R35R10AR11R12R10BR13R14R18R19R29R30R15R12ASR12A6R12A7R12A9R14A5R14A7R14A9R15A5R15A7R15A9R31R32CVHTCV03TCV07TCVOBTCV09TCV10TCV17COMPOHEHT COOLINGLOOPTOTALFLIJREFUELING MATERSTORAGETANKLVL33FOOTLEVELllINDSPEED33FOOTLEVELMINDDIRECTION 33FOOTLEVELTEMPERATURE 250FOOTLEVELTEHPERATURE 250TO33FOOTLEVELDELTATEHPAREA1CONTROLROOMAREA2-CONTAINHENT AREA5-SPENTFUELPITAREA9-LETDONN LINEMONITORAREA34-AUXBLDGCVSPRAYPUMPAREA35-PASSSAMPLEPANELCONTAINMEHT IODINEMONITORR10ACONTAINMEHT AIRPARTICULATE COHTAINHENT GASMONITORPLANTVENI'ODINE MOHITORR10BAUXBLDGEXHAUSTAIRPARTICULATE AUXBLDGEXHAUSTGASHONITORLIQUIDlJASTEDISPOSALHONITORSTEAMGENERATOR BLONDOWNDRAINAREA29-CONTAINMEHT HIGHRANGEAREA30-CONTAINMENT HIGHRANGECONDENSER AIREJECTOREXHAUSTCVVENTCHAN5-LOURAHGEGASCVVENTCHAN6-AREAGAMMACVVENTCHAN7-MIDRAHGEGASCVVENTCHAN9-HIGHRAHGEGASPLANTVENTCHAH5LOURANGEGASPLANTVENTCHAN7-MIDRANGEGASPLANTVENTCHAN9HIGHRANGEGASAIREJECTORCHAN5-LOURANGEGASAIREJECTORCHAN7-MIDRANGEGASAIREJECTORCHAN9-HIRANGEGASAREA31STEAMLINEA(SPIHG)AREA32STEAMLINEB(SPING)CVHYDROGENCONCENTRATION CVBASEMENTLVL6FTTEMP¹3CVINTERMEDIATE LVL6FTTEMP¹7CVINTERMEDIATE LVL6FTTEMP¹8CVINTERMEDIATE LVL6F'ITEHP¹9CVINTERHEDIATE LVL6FTTEHP¹10CVOPERATING LVL6FTTEMP¹171485.94.58.765'6.067.81.89.02214-02 6.40678+00 1.39946+00 '1.47701+02 9.09354-01 1.09283+00 9.58719101 5.18901+02 7.38002+02 4.30543+01 8.58327+01 4.22831+01 2.78658>03 1.57174+04 5.05861-01 5.09440.01 1.57835+03 1.89699-07 2.53990-02 3.57435-05 1.41261-03 4.40312.07 6.86543-05 3.72621-03 2.09411-07 1.34492-05 1.27941-031.87040+00 1.01048.02 .095.1106.0106.6106.7106.2117.5GOODGOODGOODGOODGOODGOGOGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODBALMGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODGOODHALMGOODGOODGOODGOODGOODGOODGOODGOODGPMxMPHDEG.DEGFDEGFDEGFMR/HMR/HHR/MHR/HMR/HMR/HCPMCPMCPHCPMCPMCPHCPMCPMR/HRR/HRCPMUCI/CCMR/NRUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCUCI/CCMR/MRMR/NRxDEGFDEGFDEGFDEGFDEGFDEGF SECTION9.0ONSITERADIOLOGICAL ANDCHEMISTRY DATA

SECTION9.1RADIOLOGICAL SUMMARY 0 9.1RadioloicalSummaA.SourceTermTheradiological sourcetermassumedforthisscenariowasselectedtoincludeappropriate quantities ofnoblegasandradioiodine resulting fromthepostulated accidentscenario. Protective actionrecommendations i.e.,sheltering orevacuation forcertainEmergency ResponsePlanningAreas(ERPAs)willnotberequiredbasedupontheanticipated declaration ofaSiteAreaEmergency andplantconditions. Asaresultofaccidentreleaserates,theprojected wholebodyandthyroiddoseswillnotexceedEPAProtective ActionGuidesbeyondtheSiteBoundary. Theassumednoblegasandradioiodine releasequantities areshowninFigure9.1asafunctionoftime.ThescenarioinvolvestworeleasepointswhichisfromtheAirEjectorandthe"A"Atmospheric ReliefValve(ARV).Thisoccursasfollows:Pre-Steam Generator TubeRuptureTime0700-0915ReleasePointAirEjectorReleaseRateCi/sec1.77E-3(NobleGas)*2.24E-8(Radioiodine)

  • Thenoblegas-to-radioiodine ratioassumedinthisscenariois7.89E4:1duringtheperiodofrelease.TimeReleasePointReleaseRateCi/sec0755-0810ARV8.32E-3(NobleGas)*1.05E-7(Radioiodine)
  • Thenoblegas-to-radioiodine ratioassumedinthisscenariois7.89E4:1duringtheperiodofrelease.SteamGenerator TubeRuptureTime0915-0935ReleasePointAirEjector'eleaseRateCi/sec5.24E-1(NobleGas)*2.62E-4(Radioiodine)
  • Thenoblegas-to-radioiodine ratioassumedinthisscenariois2000:1duringtheperiodofrelease.Isotopicbreakdowns ofassumednoblegas,radioiodine andparticulate releasequantities areprovidedinTable9.1.

TimeReleasePointReleaseRateCi/sec0935-0955AirEjector6.23E-2(NobleGas)*.3.12E-5(Radioiodine)

  • Thenoblegas-to-radioiodine ratioassumedinthisscenariois2000:1duringtheperiodofrelease.Isotopicbreakdowns ofassumednoblegas,radioiodine andparticulate releasequantities areprovidedinTable9.1..B.InteratedOffsiteDosesDuetoPlumeExosureThedownwindintegrated dosesfromthescenarioreleaseareasfollows:TimeReleasePointlnteratedDoseRem0700-09150755-08100915-09350936-0955AirEjectorARVAirEjectorAirEjector1.25E-4(WholeBody)8.75E-7(ChildThyroid)6.52E-5(WholeBody)4.56E-7(ChildThyroid)5.34E-3(WholeBody)148E-3(ChildThyroid)6.51E-4(WholeBody)1.81E-4(ChildThyroid)TotalWholeBodyDose(atSiteBoundary)

=6.18E-3RemTotalChildThyroidDose(atSiteBoundary) =1.66E-3RemC.PrincialPlantRadioloicalIndications Figures9.1through9.3providetrendplotsforkeyplantradiological indications, including plantventconcentration, letdownmonitorlevel,containment radiation levelandreactorcoolantconcentration. TABLE9.1Theassumedreleasequantities fortheGinnaExerciseScenarioaresummarized asfollows:NuclideKr-85Kr-85mKr-87Kr-88Xe-131mXe-133Xe-133mXe-135Xe-135mXe-138TotalNobleGasTime:0915-0935 hrCurie/Sec 4.0E-041.3E-021.8E-022.1E-024.9E-033.3E-014.9E-024.9E-021.6E-026.3E-025.2E-01TotalCuriesReleased4.8E-011.7E+012.3E+012.5E+015.9E+004.0E+025.9E+015.9E+011.9E+017.6E+016.3E+02I-1311-132I-133l-1341-1357.8E-051.3E-055.4E-058.6E-053.1E-059.3E-021.5E-026.3E-021.0E-013.7E-02TotalRadioiodine 2.6E-043.1E-01Long-Lived Particulate 1.2E-091.5E-06 TABLE9.1(continued) Theassumedreleasequantities fortheGinnaExerciseScenarioaresummarized asfollows:Time:0936-0955 hrNuclideCurie/Sec TotalCuriesReleasedKr-85Kr-85mKr-87Kr-88Xe-131mXe-133Xe-133mXe-135Xe-135mXe-138TotalNobleGas4.8E-051.5E-032.1E-032.5E-035.8E-043.9E-025.8E-035.8E-031.9E-037.5E-036.2E-025.8E-021.8E+002.5E+003.0E+007.0E-014.7E+017.0E+007.0E+002.3E+009.0E+007.5E+01l-131l-132l-1331-134I-1356.3E-061.5E-066.5E-061.0E-053.7E-061.1E-021.8E-037.8E-031.2E-024.4E-03TotalRadioiodine 3.1E-053.7E-02Long-Lived Particulate 1.4E-101.7E-07

FIGURE9.1ASSUMEDSOURCETERMSC1.0E+00-1.0E-011.0E-021.0E-031.0E-.041.0E-051.0E-061.0E-071.0E-081.0E-091.0E-101.0E-11I/SEC11111111777888889999990000 11113450113401334501340134 0550050505065605050505CLOCKTIME1111222201340505~NOBLEGASCI/SEC~RADIOIODINE CI/SEC FIGURE9.2AIREJECTORVENTCONCENTRATIONS UCI/CC1.0E+011.0E+001.0E-011.0E-021.0E-03-1.0E-041.0E-051.0E-061.0E-071.0E-081.0E-091.0E-101.0E-111.0E-121111111'I1111778888999999000011112222340134013345'013401340134050505050555050505050505CLOCKTIMENOBLEGAS~RADIOIODINE FIGURE9.3'CSCONCENTRATIONS VSTIME1.0E+02UCI/GM1.0E+011.0E+001.0E-011111111111117788889999000011112222I34013401340134013401340505050505050505050505CLOCKTIMETOTALGAS~TOTALIOOINE

SECTION9.2IN-PLANTRADIOLOGICAL DATAMAPS 4)\ 00DOoor25ROCHESTER GASAHDELECR'ZNNASTATZOHServteaBuddingDATE:~Kith TZME:0OOSURVEYEDBY:SURVEYINST:SERZALNUMBER:COUNTZNGZHST:SERZALNUMBER!(ONER:\(,D:goAp~)'0~n-I~IA/90."'a0me~A~Door240ClCIgC30MRREMARKS:A=0.01mR/hr(500dpm/100cm> ALLREADZHCSZNMR/HRUNLESSOTMERHZSE NOTED

~...,~~-:mOO- ~<OO~SURVEYZNSTRUNENT: SERIALNUMBER:REMARKS:AREASURVEYED: ROCHESTER GASANDELECTRICGINNASTATIONSERVICEBUILDINGNORTHSURVEYEDBY:COUNTINGZNSTRUMENT ISERZALNUMBERPOWER:LLD:RWP/SWPNUMBER:hXZ~IICIeYSWc~C.OYWIC-I'g.'IIGk.klhc.L. A=0.01mR/hr<500dpm/100cm2 ~Sj'3.IJ4JI'XJeIIIeJIE"ArfftiOR.Elbe,k. 2J2IJ20IcCeJQ2IJeJI'l.I2X2'224'2CI24JIeEIcjcd~READINGSZNMRII'HRUNLESSOTlKRIIISI NOTED9-/o

GGGCQ6608ROCHESTER GAS&ELECTR)CCORPGlNNASTAT)ONSERVICEBUILDINGp~~ypQtGASurveyedBy:SurveyMeter:SerialNumber:A=0.01mR/hr<500dpm/100cm2 Da~e:~i~i~WTime:kPower:SMEARINFORMATlON Instrument: SerialNumber:LLD:Smear¹dm/100cm2I5gi0h.-IoAIlIIIRemarks:'Vv.9.'.(l;,;~~(C:(rhCfZ>)n-i'(.i)(~;x 'I(~-I.4+4019'-//Allreadingsareinmrlhrunlessotherwise noted

~~'II~~IIaIII~~IIIIIlail1lmillLllL~ ~~'~IItIgaI~~eslIllballlIllIlll

III~~IIIII~~stttKIIll'll<mLllllll 0 RG&EGINNASTATIONTURBINEBUILDINGMEZZANINE FLOORSURVEYNAP0700'-DATE:lCClR-TLHE:HDRTHlIllIlilIIAIIIoeeeoae4A=0.01mR/hr(500dpm/100cm2 B=0.02mR/hr~500dpm/100cm2 C=0.02mR/hr850dpm/100cm2 (oncountertop ofsamplesink)DPA~Ieen~5&lQlLSsIIII~~LLllgC 0 !IORTHtTilIIIlilARC&ECINNASTATIONTURBINEBUILDINGAEZ2ANINE 9'LOORSURVEYNAPIIIeeeeoeelCR5DATE:L;IqE:~~) A=0.01mR/hr<500dpm/100cm2 8=0.80mR/hr<500dpm/100cm2 C=0.80mR/hr5000dpm/100cm2 'oncountertop ofsamplesink)uPNIavvA~~III~AIILLLlgCH'RC RC&ECINNASTATIONTURBINEBUILDINGAEZZANENE ":LOORSURVEYNhPNORTHIlIIIIIIIeeetoeeetA=0.01mR/hr<500dpm/100cm2 B=0.02mR/hr<500dpm/100cm2 C=0.02mR/hr5000dpm/100cm2 (oncountertop ofsamplesink)BQ0GPN/I.QQCi%A~~IIIIIII~IIII~I

NORTHRC6ECINNhSThTIONTURBI.iEBUILDINCBhSEHENTFLOORSURVEYKKPA=0.05mR/hr<500dpm/$00cm2B=0.02mR/hr<500dpm/100cm2 aada00OOl~oot~~~~~~~~~I~~o~~~~~~~oo~~~~~I~~~oOOG,oBioIpia.aIIIAiosDhTEi8ll-Tm:~~~POVERiBY:INSTRUMENT: SERIhLI:SNEARSD?i~i/ICC Gn~48 NORTHRC&ECINNhSTATIONTVRBINEBUILDINGBhSEMENTFLOOR,SVRVKYEXPA=0.01mR/hr<500dpm/100cm2 B=0.02mR/hr<500dpm/100cm2 4444OOOO~QE~~~~~~~~~~~'~g~~~~~~~1~t'~~O~~~~OOQIIiOIioI-La.acW(-QATE)(0RXTIME'~lOO POMR!BY:INSTRUMENT: SERIAL1:SMEARSDPMI'ICQm2iCfrEE'~Au' NORTHRC6EGINNhSThTIONTURBINEBUILDINGBhSEMENTFLOORSURVEYNAPA=0.01mR/hr<500dpm/100cm2 B=0.80mR/hr<600dpm/100cm2 oassaOOOOOOII~tQ~~~~~~0~~~~~~~~~~y~Oqt~~ADhTEsIOQQPOWERsINSTRUMENT: SERIhLftCAibTTHR:~CR0BY:D?M/LCCGn2I'rr.ir~j%i~~I'~lA)wd>"--l!>araOWp-goRENANCSs

R.E.GINNASTATION~~TEcvo>catSuwenaiCeeT~RSMEARSDPM/LOOcm;<KvDATE:~04~LTIME:GOO-CA(SPOWER:BY:INSTRUMENT: ALLREADINGSINMR/HRUNLESSOTHERWISE NOTEDA=0.01mR/hr<500dpm/100cm2 R.E.GINNA STATION'j'.Conderisati". Pcdhhln9;:;; BU!nBdinQ::,.:Contrcg 'pano'eI'rea ~'!il'!':u.s.t',ll,'Technician: Date:tbTime:~016-Gott/oInst.Type:/Serial¹'s:/Power:LLD:Note:Allreadingsareinmr/hrunlessotherwise noted.IIAtIA=0.01mR/hr<500dpm/100cm2 B=0.02mR/hr<500dpm/100cm2 C=0.02mR/hr850dpm/100cm2 (oncountertop ofsamplesink)No.etpmi100cm2 NaQHTankH2S04TankToAVTDlRoom.SampleSinkBAno/rrsrRodtlonitorA6AVTControlPanelH20HeaterDeskDoor28Door67Door19!¹=SmearLocationRadiation Level'=ContactReadingechnician Remarks:BrQA:ew'.(t.-\'t-x-x-=Rad/Cont. BarrierNeutronRadiation LevelI-I("GArk/-.-I~V.'oa'*~iedt.~!r').~-Q'.<<t~~tO00=Cont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighRad..Area . LLD:R.E.GINNA'TATION ';"Co'nderisate'.,'.,:..l,'oils>In9,"-.'Bulldin'O.-'-"'.Contre'8,'; Paneal:A'rea', 'echnician: Date:0('RWTime:CA&-'l450Inst.Type:-/Serial¹'s:/Power;Note:Allreadingsareinmr/hrunlessotherwise noted.A=0.01mR/hr<500dpm/100cm2 B=0.30mR/hrNo.dpm/100cm2 (AII(AII5000dpm/100cm2 (oncountertop ofsamplesink)NoQHTonkH2S04TonkToAVTDlRoomSampleSinkRortrN'tet-~A6AVTControlPanelH20HeaterDoor28Door67Door19¹=SmearLocationRadiation Levelc=ContactReadingechnician Remarks:!\M-"r~=-x-x-=Rad/Cont. BarrierNeutronRadiation LevelIg.'ur.')gt~vmtr.c.)C*i'.)riCont.AreaHighCont.Area!Radiation AreaHighRad.AreaLockedHighRad.;Area

R.E.GINNA STATION:RCOn4eS'at8'",.FP'IIShfA'g,':,;Bulfdjig':,;"'>>"'"",Dem'jneraaljiear.'raea.' Technician: Date:RLTime:Q7~-OQlSInst.Type:/Serial¹'s:IPower:LLD:Note:Allreadingsareinmr/hrunlessotherwise noted.HighCondensate WasteTankLowCondensate WasteTankellfelt'oof 27No.dpm/100cm2 B0DDeminDiluteNH4QH00MixedCDeminDiluteNaQHAnionRegenBDeminDiluteH2SQ4CationRegenADeminA=0.01mR/hr<500dpm/100cm2 B=0.02mR/hr<500dpm/100cm2 SmearLocationRadiation Levelr~c=ContactReadingechnician Remarks:<<IPIP'i-x-x-=Rad/Cont. BarrierNeutronRadiation LevelIs/.~~n-.V(4.u/(c.\ic.,cr'N-Wtc-(C)0ps+p=Cont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighRad.Area 4

.~Co'n'dinsat'8','.:Peflitifiig,'-.,'Biiildjijj';-."""-Oemineraltzer';:;Artea:::.

Technician: Date:0l>lime:~1k-.l rDDInst.Type:/Serial¹'e:IPower:Li.o:Note:Allreadingsareinmr/hrunlessotherwise noted.HighCondensate WasteTankLowCondensote WasteTankI>>Iel'oor27INo.tdpm/100cm2 I0DDeminDiluteNH40HMixedCDeminDiluteNaQHAAnionRegen8DeminDiluteH2S04CationRegenADeminA=0.01mR/hr<500dpm/100cm2 B=0.80mR/hr<500dpm/100cm2 O¹=SmearLocationRadiation Levelc=ContactReadingechnician Remarks:-x-x-=Rad/Cont. BarrierNeutronRadiation LevelAr(rrY~J2)tc0-l~-tCont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighRad.Area

R.E.GINNA STATlONTechnician: Date:IoIll.Time:61co -A3t)inst.Type:Note:Allreadingsarelnmr/hrunlessottterwise noted.-.i:QOOVI'$-'odpm/100cm2 0000cv'Purge--->(---NA=0.01mR/hr<500dPm/100cm2Containment R10A,11,12 CVVent-->PlantVent--->----R10B,13,14 000000APurgeExhaustFanoAo8PurgeExhaustFan¹=SmearLocationRadiation Levelc=ContactReadingTechnician Remarks:(tP-x-x-=Rad/Cont. BarrierNeutronRadiation Level>+i(ut=CIŽ(0Cont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighRad.Area

R.EeGINNA STATION.2%5:c'"jt <tglS'att@c~p'.g~+":ri~i~Lt:j~~e:

i."'~Cer;~~.y

i~@';%%Jr'Ya ttr:"~"Sq::tlag>,~'; Technician: Ttme:~000-IIOC)Inst.Type:IPower:LLD:Note:AllreadingsareInmr/hrunlessotherwise noted.No.dPm/100cmg A=0.0tmR/hr<600dpm/100cm2 A<---NCorltoinment APurqet:xhoustFan8L0W0LR0Autjn4Sleon8PurgeshousTrtstOoar57ChernisTrT L<OOJ.Woler-slorogeTonk00¹=SmearLocationRadiation Levelc~ContactReadingechnician Remarks:-x-x-=Rad/Cont. Barrier~~NeutronRadiation LevelJ,;~&un4'-.,;ri-(.)~C(C~h~Pic-i(.t)rr-k -~'t2-tCont.AreaHighCont.AreaiRadiation AreaHighRad.AreaLockedHighBad..Area R.E.GINNA STATlON'~~rdglottINSSW" STottkg~RTa'aa'iiiT)~::::L'at'rtal-,-:.". Technician: Cate:~Ttma:67CO-Cert~ inst.Type:/Serial¹'a:lpc~et.Note:Allreadingsareinmr/hrunlessotherwise noted.dpm/100cm2 BMainSteam--'>AOiA=0.01mR/hr<500dpm/100cm2 8=0.05mR/hr<500dpm/100cm2 (--NContainment AQ0AMainSteam-->rWIIIIIIHHBRacttimTonk0IIIIIIIAOoor45AgoQ¹=SmearLocationRadiation Levelc=ContactReading,echnician Remarks:'t'Q'9;u~~tI(".(~I-->0-x-x-=Rad/Cont. BarrierNeutronRadiation LevelCont.ArearQ>>HighCont.Area+=Radiation AreaQHighRad.AreaOLockedHighRad.Area R.EeGINNA STATlONTechnician: Date:l0'KlI'LTirae:gil6-0<< QInst.Type:/Serial¹'a:ipew:LLDNote:Allreadingsarelnmr/hrunlessotherwise noted.No.dpm/100cm2 8MainSteam-->lAIA=0.01mR/hr<500dpm/100cm2 B=3.0mR/hr<500dpm/100cm2 (--NContainment BAMainSteam-->0IBcHHBReottartt fora0IIIIA000f45go¹=SmearLocationRadiation Levelc=ContactReadingechnician Remarks:-x-x-=Rad/Cont. BarrierNeutronRadiation Level\4(>>'>>'k>l(r~(p(-'ic.uh(~i =~iE-tbCont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighRad..Area R.E.GINNA STATION'<<A<<"'~>>(+;<<>>~+~>>'re>>>>')i';:<',re'>>>>r>> gz'dye4jtt",*>>'~rr";t".V>>+% Technician: Date:Il1-Time:~-QOOInst.Type:/Serial¹elpo:LLD:Note:Allreadingsareinmr/hrunlessotherwise noted.No.dpm1100cm2 BMainSteam-->IIArlrr~C~rPI>>A=0.01mR/hr<500dpm/100cm2 B=0.3mR/hrI<500dpm/100cm2 (--NContainment AMainSteam-->INSRectorn1onh0IIIIIIIIIIIADoor45AHoQ¹=SmearLocationRadiation Levelc=ContactReadingechnician Remarks:(t;-i-x-x-~Rad/Cont. BarrierNeutronRadiation LevelCont.Area0>>HighCont.Area+=Radiation AreaQ>>HighBad.AreaOLockedHighRad.Area R.E.GINNA STATlON::.'"'~~~Q~4%%~"P>%<~pa)'~~..<p4<+m~..:jm" ".-+'.::'MOc'.":~<to,e.'-'~~a."kw~'~"'35F<t<'<e<'<'j)v Technician: pate:0l-Time:CQX) "MLSinst.Type:Note:Ailreadingsareinmr/hrunlessotherwise noted.Cable--->TunnelEntry0A=0.01mR/hr<600dpm/100cm2 B=0.05mR/hr<600dpm/100cm2 (--NNo,dpm/100cm2 Door36Containment Turbine0DrivenAux.FW~<Pump---0Door37TurbineAux.PW-PumpOilTank)~ljljAr-iDASo~o8Chillers0MotorDrivenAux.FWPumps-----""000Q¹=SmearLocationRadiation Levelc=ContactReadingechnician Remarks:~lr=-(<-x-x-~Rad/Cont. Barrier~NeutronRadiation Level'~cQt~u(~"i< =tC-'lieCont.AreaHighCont.Area!Radiation AreaHighRad.AreaLockedHighRad.Area R.E.GINNA STATlONTechnician: i):u~2%'pb.>'e.;:,. ',.TQ~,"'>>p,>+'N~:+>:A,gj~ej+i>> ';>e'>'>r~9?~i~i~+<>>>>T>>>$ >>%~)'~'tntmtedfko. -":g~'-.IItaeNat"k4vof fnst.Type:/Serial¹'s:Note:Ailreadingsareinmr/hrunlessothertlvise noted.Power:Cable---)TunnelEntry0O0A=0.01mR/hr(500dpm/100cm2 B=2.0mR/hr<500dpm/100cm2 dpm/100cm2 Door36AContainment TurbineDrivenAux.FWPump---Door370~~B)O0OO0~c+>".,".'7w ->~DOA~DSo3o8Chitters0MotorDrivenAuxFWPumps------- 000¹=SmearLocation!Radiation Levelc~ContactReadingechnician Remarks:k)c',i:s=-x-x-~Rad/Cont. BarrierNeutronRadiation LevelA>M'l9t'<-..i'rvvGCc.C'iF-toICont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighRad.Area R.E.GINNA STATKRIA=0.01mRlhr<500dpm/100cm2 Note:Allreadingsarein,hitarinadhte-: BiiMa9:.:: South;"-MezxeHnsk.eveloats:tCIstt'LTime:~aCr-t/taoSerial¹'s:/Power:LLO:mr/hrunlessotherwise noted.Door46Door45No.dpm/100cm2 Door65ControlPoint/Sign-inDeskContainment PassbosNuclearjSamplejRoomINuclearSampleShedHEPAFittersDoor503echniclan Remarks:'two"-(C.-'l,Q¹=SmearLocationRadiation LevelI¹'c=ContactReadingTt4v~t'tv'-Aha(C4ir-.r,a.=Cl~-l0-x-x-=Rad/Cont. BarrierNeutronRadiation LevelsCont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighRad.Area A=0.1mR/hr<500dpm/100cm2 B=10'-'R/hr<500dpm/100cm2 ",;fnrtefinadfati'-',BiiMiij.'.,S{iuth;:= Mezz~ILese}.'Rli%Time:455lulrocto+Date:l0Serial¹'s:/Power:LLD:(hrunlessotherwise noted.Crol((Ooor46Ooor45ND.dpm/100cm2 Ooor65ControlPoint/Sign-inOeskContainment PassboxNuclearlSomplel'oomrINucleorSampleShedHEPAFillersOoor503;Qar=SmearLocationRadiation Level'¹c=ContactReadingTechnician Remarks:8>"-Ltt'g'Ag(ut~t>Gcc=((~-tO-x-x-=Rad/Cont. BarrierNeutronRadiation Level!0Q>>+8=+Cont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighBad.Area R.E.GINNA STATION'ntermidiats SiRdln9South',-Basement'evei A=0.01IR/hr<500dpm/100cm2 Date:lbILTime:~b~oO l/00Serial¹'s:/Power:LLD:Note:A/Ireadingsaremmr/hrunlessotherwise noted.QQuottgVtOoor38No.dpm/100cm2 ToHotShop<---LaundryTanks1AHydrogenRecombiner PanelsContainment ChemicalDrainTankHPAChascad/SpenlFuelPil,SkimmerFiller8Conlrolled AccessFansie0I,(Q¹=SmearLocationl~=Radiation Levelc=ContactReadingechnician Remarks:c-x-x-=Rad/Cont. BarrierNeutronRadiation LevelI<<trlr<<w(u+it'~c'.Z=Zt-'tb40=Cont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighRad.Area A=0.1mR/hr<500dpm/100cm2B=100mR/hr<600dpm/100t:m2 A."fntermediati; Rdh8ns-South.-Basernera'evel Date:lOl~Time:~ASS IAopRr~rortSerial¹'s:/Ihrunlessotherwise noted.Ooor38No.dpm/100cm2 ToHotShop<---l.aundryTankslAAIBHydrogenRecombiner PanelsContainment ChemicalOrainTankHPAAiilrrsopSpentFuelPitSkimmerFillerControlled AccessFansIA6,V+¹=SmearLocation!=Radiation LevelContactReadingechnician Remarks:4tF-(t,-x-x-=Rad/Cont. BarrierNeutronRadiation Level(.~ucicehc=(tC-t40=+0=Cont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighRad.Area e R.E.GINNA STATIONmin'ated; StorageBuBdineTechnician: Date:9'LTime:QlQQ -4tDI-Iinst.Type:Serial¹'s:/Power:LLD:Note:Allreadingsareinmr/hrunlessotherwise noted.A=0.05mR/hr<500dpm/100cm2 No.dpm/100cm2 Door6l0SlorageRacksArt>>stoaISALSASlorageRacksRCPMolorR~0ILvlP00R-X---X---XIoIIXOeconAreoSlorageRacksIISmearLocationRadiation Level'c=ContactReadingechnician Remarks:-.x=()-:-'t'i -x-x-=Rad/Cont. SarrierNeutronRadiation Level~CiccPrt>tC.<hD>-~lCr3~40=Cont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighRad.Area 0 ..:.:;~:.8P'int;.'Fiiet"'M any"i)econpttTechnician: Date:'lolSRLTiote:~~0-tWOQinst.Type:/Serialrr'e:IPower:LLD:Note:Allreadingsareinmr/hrunlessotherwise noted.A=0.10mR/hr<500dpm/100cm2 No.dpm/100cm2 R-188----x--x----r--r--- IXOeconPitXIXIIDrainXQXXIXCATWAKIXSpentFuelPitIXIXIXIXIXIX~BridqeIXIXIrIXIXIXIXIXIXxCRSHEPAFiltersII'rosre.mI~sori-..--.-..TransferCanal~sopNewrvetStoraqeAreochnlcianRemarks.CtISmearLocationlRadiation Level¹c=ContactReading'e-x-x-=Rad/Cont. BarrierNeutronRadiation Levelh,~4-c;.0=Cont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighRad.Area9-3B R.E.GINNA STATlONA=0.50mR/hr<500dpm/100cm2 .;:.:..Ru88ary Sultry,,OPerat@g,'k;ever -NestEndDate:lO8LTime:CQCO-(400Serial¹'e:IPower:LLD:Note:Allreadingsareinmr/hrunlessotherwise noted.No.'pm/100crnR NewFuelStorageDoor29AOg-CVPenetrolion ron00CCWH000RWSToOOSmearLocationRadiation Level¹c=ContactReadingTechnician Remarks:tf~'CrC'ri'D,'~C(c~hC>~-tG-x-x-=Rad/Cont. BarrierNeutronRadiation Level0=+6=+Cont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighRad.Area R.E.GINNA STATION':".'AuxIII&~~.'aiilfdInjp)itteimodfato. Legal:-.'-. infestEndA=0.10mR/hr<500dpm/100cm2 Date:le'8lTime:e7ee-geeSerial¹'a:/Power:LLD,Note:Allreadingsareinmr/hrunlessotherwise noted.ACVCSqQhlerNo.~dpm/100cm2 A8CVCS~>~i~>~>CCVCSXXXXXi~~xIIXRWSTAwGCRoomAn:Q>=SmearLocationRadiation Level¹c=ContactReadingTechnician Remarks:'k':z=Z't~-t,k-x-x-=Rad/Cont. BarrierNeutronRadiation Level00=Cont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighRad.Area I R.E'GINNA STATlON-A=0.10mR/hr<500dpm/100cm2

,';AUXIN~

BUffcQAQ. 88$8ntent:LevEA'.@fest-EndDate:1't>KTime:gQd-IGLOOSerial¹'s:/Power:LLD:Note:Allreadingsareinmr/hrunlessotherwise noted.Art(BSFPPUMPSNa..dpm/100cm2 ACVCS--Ad(BRHRFansXXeete.I8CVCSQA8EAxQaCCVCSRWSTREEterCAXtLx-x-GSPIIPFKi~;(¹+=SmearLocationRadiation LevelI¹c=ContactReadingTechnician Remarks:-x-x-=Rad/Cont. BarrierNeutronRadiation Level~/rA'crxvArsivir<<C'e%QltA&t(v.<<tt-tl-IrQCont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighRad.Area R.E.GINNA STATION'QxN~."',BUIding;'t Operating; L'eve(,tDate:Ct'tti(l>Titne:Q7gDt+DOA=0.10IR/hl'500 dpm/100cm2 Serial¹'s:/Power:LLD:Note:Allreadingsareinmr/hrunlessotherwise noted.AMonitorTonk~VVIAxIBIII;g)xlotli';0ggQ0RWSTBus14Door261ttpm/100cm2 BMonitorTonkAAux.Bldg.SupplyA/HUnitRMWTooooo~erettte0riroeesstno 0QResinlinerppABAST88ABASTratergner0Door28Door27BArretisems p~0'~+¹=SmearLocationRadiation Leveli¹c=ContactReading,Technician Remarks:'I,Zll--tttcMt(/>~iKrM&ClCC.-x-x-=Rad/Cont. BarrierNeutronRadiation LevelcJ=Cont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighRad.Area RE.GINNASTATtONA=0.10mR/hr(500dpmI100cm2 Note:AllreadingsareinAuxiHary::.SiiHdlrTS'fat8rmetHate,.Levd: -pastaidDate:'IQl6C.Ttrne:~QQOQ-(QOQSerial¹'s:/Power:LLD.mr/hrunlessotherwise noted.RWSTNo.'pm/100cm2 AGPTBus1644AIBGPT~ooA.'0GCharcaaf/HERA rillerCGPT,SDPpGOT0AooOoRCfillerPlVaultVCTCHTLoAOrI";¹)=SmearLocationRadiation Levelc=ContactReadingFechnician Remarks:Ktwa.=~lE-lK<~>>((<rt=(lf=-lo-x-x-=Rad/Cont. BarrierNeutronRadiation l.evelAh~C;1c~tCont.AreaHighCont.AreaRadiation AreaHighRad.Areal.ockedHighRad,:.Area R.E.GIKNA STATloN'Auxlli~" BQQdjnQ>'. 80$8Ntnf,Levg-A=0.10mR/hr4500dpm1100cm2 Date:LO.LTime:CQ~-b5(5'erial ¹'s:/Power:LLp,Note:Allreadingsareinmr/hrunlessotherwise noted.Npdpm/100cm2 WHUrPompAaStPumps~~~~~~e~e~~eee~~e~~~CSPumpsegQQAWasteHoldupTankmiami,IXIXI=.,Xjoe't-000BREcWOA+9ChorgingPumpCoolingFansANon-regen HxSeprRetientWEFTOorn~48~LR~t:0rr0~ouT.RSpentResinTankRoomSureTank~4ChorgingPumpRoomCl;~lNaoH'Ie~echntctanRemarks.~Dire=i'.¹~SmearLocationRadiation Level'¹c=ContactReadingTe-x-x-=Rad/Cont. BarrierNeutronRadiation Level7~!0c<hit5VG/CChI-ZiC-tO000=Cont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighRad.Area 0 R.E.GINNA STATIONA=0.1mR/hr<500dpm/100cm2 B=100mR/hr<500dpm/100cm2 Date:(0Time:O'QQ--.',f gggSerial¹'s:/r/hrunlessotherwise noted.Power:LLQ.-':.Auxlllacy~ ByQdfii9;.':BiWfliBAf LeveIrdpml1OOcm2 WasteHoldupTonkGAwHUTpRunO0XjBRImiicwpxt'XIXWEXI4'l000AAArttITChargingPumpCoolingFansSlPumps~~~~~~~~~~~~~~~~>>~~~~~~~>>~~~~~8ACSPumps~ANon-regen HxgJAlcQ~SectReturnOoXt~~~B88~tR~t:0Na4puERSpentResinTankRoomSureTankChargingPumpRoomNOOHchntctanRemarks.'ve=(ll=-((.I~'t~¹=SmearLocationRadiation Level~~~'¹c=ContactReadingTet(t.)tcX'atr--x-x-=Rad/Cont. Barrier~~NeutronRadiation LevelrY&wrrr&Alibifr>>CirChQ>>+0=Cont.AreaHighCont.AreaRadiation AreaHighRad.AreaLockedHighRad.Area SECTION9.3IN.-PLANT ANDPOST-ACCIDENT SAMPLINGRESULTS TABLE9.2ANuclideKr-85mKr-87Kr-88Xe-133Xe-135Xe-135mXe-138Rb-88REACTORCOOLANTSYSTEMRadioactive Gassesandlodines(Collection between07:00-09:15)Concentration (pCi/gm)Corrected totimeofShutdown2.88E-024.02E-024.66E-02'.51E-011.10E-013.72E-021.43E-012.62E-02GasTotal1.16E+001-1311-132l-133l-1341-1353.20E-021.05E-014.18E-021.51E-017.55E-02iodineTotal4.05E1I-131DoseEquivalent 4.7E-02 TABLE9.2BRCSGasSampleNuclideKr-85mKr-87Kr-88Xe-133Xe-135Xe-135mXe-138Rb-88REACTORCOOLANTSYSTEMRadioactive Gassesandlodines(Collection between09:16-14:00)Concentration (pCi/gm)Corrected totimeofShutdown2.88E-014.02E-014.66E-017.51E+001.10E+003.72E-011.43E+002.62E-01GasTotal1.16E+01RCSGasSampleDoseRate(basedon35ccsample)1meter=0.195mR/hr1foot=2.44mR/hrOncontact=1.95R/hrRCSLiquidSampleNuclideI-131I-132I-1331-134I-135Concentration (pCi/gm)Corrected totimeofShutdown2.72E-011.76E-011.65E-011.51E-011.53E-01IodineTotal9.17E-01I-131DoseEquiv3.10E-01RCSLiquidSampleDoseRate(basedon12ccsample)1meter=<0.01mR/hr1foot=0.06mR/hrOncontact=52.8mR/hr TABLE9.3ANuclideI-131I-132l-133I-134I-135Cs-134Cs-137STEAMGENERATOR (Collection between07:00-09:15)Concentration (pCi/gm)Corrected totimeofShutdowneIAee~IBee3.78E-051.62E-071.35E-056.33E-074.65E-051.03E-061.56E-045.85E-078.73E-051.22E-063.27E-064.64E-082.96E-067.20E-08TOTALACTIVITY3.47E-043.75E-06SampleDoseRates(basedupon3500ccsample)IIAII1meter<0.01mR/hr1foot<0.01mR/hrOncontact5.83mR/hrII8II<0.01mR/hr<0.01mR/hr<0.01mR/hr TABLE9.3BNuclideI-131I-132I-134I-135Cs-134Cs-137STEAMGENERATOR (Collection between09:16-13:00)Concentration (pCi/gm)Corrected totimeofShutdown~IAll2.8E-021.8E-021.7E-021.5E-021.5E-022.9E-04IlBl~5.93E-055.38E-062.56E-053.13E-061.87E-05TOTALACTIVITY9.33E<21.12E-04SampleDoseRates(basedupon1000ccsample)IIAII1meter0.045mR/hr1foot0.56mR/hrOncontact449mR/hrIIBII<0.01mR/hr<0.01mR/hr0.538mR/hr TABLE9.4AAIREJECTOR(Samplecollection between07:00-09:15)NuclideKr-85mKr-87Kr-88Xe-131mXe-133Xe-133mXe-135Xe-135mXe-138Concentration (pCi/gm)Corrected totimeofShutdown5.59E-035.26E-039.21E-031.38E-029.87E-022.40E-033.95E-026.25E-032.67E-02TOTALGAS2.07E-0135ccSampleDoseRateoncontact=35mR/hrDoseRateat1foot=0.04mR/hrDoseRateat1meter=<0.01mR/hrFlowrate=0.21cfm TABLE9.4BAIREJECTOR(Samplecollection between09:16-09:35)NuclideKr-85Kr-85mKr-87Kr-88Xe-131mXe-133Xe-133mXe-135Xe-135mXe-138Concentration (pCi/gm)Corrected totimeofShutdown3.72E-021.18E+005.06E-011.91E+004.53E-013.96E+014.76E+004.73E+00'I.73E+00 5.97E+00TOTALGAS5.65E+01DoseRateoncontact=1.0E+04mR/hr*DoseRateat1foot=11mR/hr*DoseRateat1meter=1mR/hr**assumesa35ccsample TABLE9.4CAIREJECTOR(Samplecollection between09:36-09:55)NuclideKr-85'r-85m Kr-87Kr-88Xe-131mXe-133Xe-133mXe-135Xe-135mXe-138Concentration (pCi/gm)Corrected totimeofShutdown4.87E-031.55E-016.62E-022.50E-01.5.93E-024.03E+005.97E-015.93E-012.00E-017.68E-01TOTALGAS6.72E+00DoseRateoncontact=1.1E+03mR/hrDoseRateat1foot=1.2mR/hrDoseRateat1meter=0.1mR/hr TABLE9.4DAIREJECTOR(Samplecollection between09:56-14:00)NuclideKr-85'r-85m Kr-87Kr-88Xe-131mXe-133Xe-133mXe-135Xe-135mXe-138Concentration (pCi/gm)Corrected totimeofShutdown1.92E-096.10E-082.61E-089.85E-082.34E-081.59E-062.35E-072.34E-072.20E-073.03E-07TOTALGAS2.79E-06DoseRateoncontact=<0.01mR/hrDoseRateat1foot=<0.01mR/hrDoseRateat1meter=<0.01mR/hr TABLE9.5ACOMPONENT COOLINGWATER(CCW)SYSTEM(Collection between08:30-14:00)Activity=2.51K-05pCi/gmChromates =154ppmpH=8.0TABLE9.6BWASTEHOLDUPTANK(WHUT)(Collection between08:30-14:00)Activity=2.3E-05pCi/gmChromates =20ppmpH=6.7 TABLE9.6CONTAINNlENT HYDROGENCONCENTRATION Time06:30-14:00HdroenVOL.%0.0TABLE9.7ReactorCooiantSstemRCSandContainment SumBoron/HData~SamleRCSRCSRCSSumpTime06:45-09:15 09:16-09:30 09:31-14:00 06:45-14:00mBoron57120972207<10.pH6.85.14.77.5 TABLE9.8CONTINUOUS AIRMONITORREADINGSINAUXILIARY BUILDING(READINGS INCOUNTS.PERMINUTE)0630-1130 hrs:TOPFLOORINTERMEDIATE FLOORBASEMENTFLOORGAS5050100IODINE100100200PARTICULATE 10010020009:16-10:00hrs:TOPFLOORINTERMEDIATE FLOORBASEMENTFLOOR1005010020010020020010020010:01-14:00hrs:TOPFLOORINTERMEDIATE FLOORBASEMENTFLOOR5050100200100200200100200 TABLE9.9AIRSAMPLERESULTSINTSCANDCONTROLROOM(Readings inCountsperMinute)07:00-09:15hrs:TSCCONTROLROOMIODINE5050PARTICULATE 5050BACKGROUND 505009:16-10:00hrs:TSCCONTROLROOM80805050505010:01-14:00hrs:TSCCONTROLROOM505050505050 METEOROLOGICAL ASSUMPTIO SECTION10.0METEOROLOGICAL ANDOFFSITERADIOLOGICAL DATA SECTION10.1METEOROLOGICAL DATAPLUMEDIRECTION WEATHERFORECASTS ANDTOWERDATA FIGURE$0,.4D)RECTION OFTHEPI.UMK-t.,I~~'aiI~)j'oifs.I'e~/'.7'III,aI.'e94!22:-'=WeWebster.- JIirIo~~Vice<<~WoioeIoaoOooehaOIe'i/I>>oc'aa75~er"-1t!ti/~/.~./.~'/5eOoei/Ij~~~iiI'~".-EIIOt/"Rochesce~r'OIalaerI~eillfO$oea/"V/-~rAaeoaFoa$rl~Wiiataro~~g/iI'TI"IWmWolaooolh aooi'I;SroCOdoei Wahoaeloora>>ihlmSairaaiC~oFIiree./orooiI>.-r+IFoohoeaIaAal,~.'iI"5ZSgo'002'5SCALE1:IpppppICOOICQWS'ChM&2H/OI/OOOO/oiS Ik+OICI(hIleoIloeCOO$015iaamCoeaiiONrhfgo~iaI'oeeoaaoooea iI/eaaaa>>I/~ileeeaaat//OglOCOO25ICOIOCOIlaINOO~~20ON15I225IION%UZI'0CO MoroloicIndiinA.~BaisThemeteorological conditions forthisscenariowerebaseduponhistorical meteorological datarecordedbytheGinnaprimaryweathertowerandtheNationalWeatherServiceonAus221988.Minoredittingwasperformed onthedatatoprovidethewinddirection andatmospheric stability conditions requiredbythescenarioduringtheperiodofrelease.NationalWeatherServiceandotherExercisecontrollers willprovideExerciseparticipants weatherforecastsummaries basedonthemeteorological dataandothersupporting information available fromthehistorical record.Thegoalofthisapproachistoprovideparticipants withmorerealistic forecastinformation. B.ScnriAminThescenariobeginswithlight,southerly windswhichshiftandbecomenortheasterly bymid-morning. DuringtheperiodofreleaseduetotheSteamGenerator TubeRupture(0915-0955 hr),theaveragemeteorological conditions areasfollows:WindSpeed=5mph(at33ft)WindDirection =50degrees(at33ft;windfrom)PasquillStability =E10-4. TABLE10.1WEATHERFORECASTINFORMATI NOCTOBER8,19927:30AM-3:00PMLAKEONTARIOFORECAST: TODAY:SOUTHERLY WINDSWILLBESHIFTINGNORTHEASTERLY BYMID-MORNING.TEMPERATURES EXPECTEDINTHEMID-TOUPPER60'S.WINDSWILLREMAINFROMTHENORTHEAST AT5MPHTHROUGHOUT THEREMAINDER OFTHEAFTERNOON. NOTE'UPPLEMENTAL FOREASTINFORMATI NTBEPROVIDEDBYNATIONALWEATHERSERVICECONTROLLER ATTHEFOLLOWING TELEPHONE NUMBER:7162-7633ORBYDESIGNATED NYSCONTROLLER INALBANY.10-5. PRINTOTSFRIVIINNAPRIMARYMET.TWER(15-MINUTE AVERAGES) 10-6. PRINTOUTPROMGINNAPRIMARYMETeTOWERIBMPCTERMINALAV10/8/9206:45RECORDNUMBER3974RG&EGINNAPLANTSENSORNAMESPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250"ER33A57.1MPH7'MPH197.0DEG196.0DEG174.0DEG56.0DEG198.0DEG48.8AVERAGEUNIT3.6MPH3'MPH4.5MPHCODESTDDEV0.90.80.90.00.49.09.03.00.010.0MIN2.87.02-32'6.86.957.013'57.215.1178.0232.0179.0225.0166.0183.055.057.0174.0230.0TER33BTER150ATER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B 48.749.251.455.22.62.46.56.0PRECIPITATION 1.08F/F/F/F/0INCH00.000.000.00 PRINTOUTFROMGINNAPRIMARYMETTOREBMPCTERMINALAV10/8/9207:00RECORDNUMBER3975RG&EGINNAPLANTSENSORNAMEAVERAGEUNITCODESTDDEVM~ISPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250TER33Ai'ER33B57.16.1209.0195.0174.056.0188.052.953.3MPH0MPH0MPHDEG0DEGDEG0DEG0DEG00MPHMPH00.90.8~0.0.0p~411.07.03.00.09.02.87.02-36.82'57.013-2183.0197.06.957.215.1247.0295.055.0184.057.0230.0166.0183.0TER150ATER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B 53.655.45.03.02.5"2.0PRECIPITATION 1.08FF/F/F/pF/0INCH00.000.000.00 PRINTOUTPROMG1'NNAPRIMARYMETTOWERIBMPCTERMINAL%V10/8/9207:15RECORDNUMBER3976RGS(EGINNAPLANT'ENSOR NAMESPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250ER33ATER33BTER150ATER150BTER250A3.83.94;857.17'193.0197.0184.056.0188.052.953.353.353.655.5MPHMPHMPHMPHMPHDEGDEGDEGDEGDEGCODESTDDEV0.90.80.90.00.49.07.03.00.01.0MIN2.87.02'6.82'57.013-2172.06.957.215.1229.0197.0295.055.057.0154.0160.0166.0183.0DT150-33A DT150-33B DT250-33A DT250-33B 0.40.32.52-3PRECIPITATION 1.08F/F/F/0F/0INCH00.000.000.00 PRINTOUTFROMGINNAPRIMARYMETTONERIBMPCTERMINALWV10/8/92~0:30RECORDNUMBER3977RG&EGINNAPLANTSENSORNAMESPD33ASPD33BSPD150ASPD150BSPD250DIR33A'DIR33BDIR150ADIR150BDIR250ZER33AAVERAGE3'3'4.557.17'202.0195.0174.056.0158.053.0MPHMPHMPHMPHMPHDEGDEGDEGDEG'DEGCODESTDDEV0.80.90.00.49.07.03.00.01.0MIN2.87.02-36.82'57.013-26.957.215.1172.0229.0197.0166.0295.0183.055.057.0154.0160.0TER33BTER150ATER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B 53.153.453.555.50.40.52.52'PRECIPITATION 1.080F/F/F/0F/0INCH00.000.000.00 PRINTOUTPROMGINNAPRIMARYMETTOWERIBMPCTERMINALXV10/8/9207:45RECORDNUMBER3978RG&EGINNAPLANTSENSORNAMESPD33A.SPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250x'ER33ATER33BTER150ATER150BTER250A57F1MPH7'MPH215'198.0DEGDEG201.0DEG56.0DEG158.053.5DEG53.753.553.655.6AVERAGEUNITMPHMPHMPHCODE0STDDEV0.90.80.90.00.411.011.013.00.01.0MIN2.82-32'57.013'184.0197.0175.055.0154.07.06.86.957.215.1242.0255.0238.057.0160.0DT150-33A DT150-33B DT250-33A DT250-33B 0.00.02-11.9PRECIPITATION 1.08F/F/F/0F/0INCH00.000.000.00 PRZNTOUTPROMOZNNAPRIMARYMETTOWERZBMPCTERMINALAV.10/8/9208:00RECORDNUMBER3979RG&EGINNAPLANTSENSORNAMEUNITCODESTDDEVMINMAXSPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250TER33A3.63.54.757'F1222.0230.0202.056.0168.057.7MPHMPHMPHMPHMPHDEGDEGDEGDEGDEG0000000.90.80.90.00.413.07.03.00.03.02.87.02'2'6.86.957.013.2186.057.215.1268.0197.0295.055.0154.057.0180.0179.0230.0ER33B57.7TER150ATER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B 57.957.958.00.20.20.30.1F/F/F/F/0000PRECIPITATION 1.08INCH00.000.000.00 PRINTOUTPROMGINNAPRIMARYMETTONERIBMPCTERMINALAV10/8/9208015RECORDNUMBER3980RG&EGINNAPLANTSENSORNAMEAVERAGEUNITCODESTDDEVMINSPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250'ER33A3.63'4.557'F1194.0195.0174.056.0158.058.7MPHMPHMPHMPHMPHDEGDEGDEGDEGDEG0.90.80.90.00.49.07.03.00.01.02.87.02-32-757.013'172.0197.06.86.957.215.1229.0295.055.057.0154.0160.0166.0183.0TER33BTER150ATER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B 58.757.958.158.00.80.8-0.7-0.7PRECIPITATION 1.08F/F/F/0F/0INCH00.000.000.00 \PRINTOUTFROMGINNAPRIMARYMETTOWERIBMPCTERMINAL%V10/8/9208:30RECORDNUMBER3981RG&EGINNAPLANTSENSORNAMESPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250AVERAGE2'2.53'57.23.547.042.065.055.064.0MPHMPHMPHMPH-MPHDEGDEGDEGDEGDEGCODESTDDEV0.92.00.03.03.08.014.00.03.0MIN3.03-73.057.112'~08.0110.05.054.015.09.78.711.057.214.4312.0300.0153.056.0141.0z'ER33ATER33BTER150ATER150BTER250A59.659.658.858.858.9DT150-33A DT150-33B DT250-33A DT250-33B 0.80.8-0.7-0.7F/F/F/F/PRECIPITATION 1.08INCH'0.000.000.00 PRINTOUTPROGINNAPRIMARYMET4TOWEBMPCERMILAV10/8/9208:45RECORDNUMBER3982RG&EGINNAPLANTSENSORNAMESPD33ASPD33BSPD150AAVERAGEUNIT3.8MPHMPHMPHCODESTDDEV0.80;91.0MIN2-32.62'7-77'7.5SPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250TER33AZER33B57.27'79.082.085.056.079.059.859.8MPHMPHDEGDEGDEGDEGDEG0.00.915.014.06.0"0.03.057.18.644.040.057.313.6118.0128.055.056.0144~0167.0145.0178.0TER150ATER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B 59.459.459.0-0.4-0.4-0.8-0.8PRECIPITATION 1.08F/F/F/F/0'INCH00.000.000.00 'I PRINTOUTPROCINNAPRIMARYMETiTONEIBMPCTERMINALAV10/8/9209:00RECORDNUMBER3983RG&EGINNAPLANTSENSORNAMESPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250TER33AF13'5.257'9.552.054~055.056.557.059.9MPHMPHMPHMPHDEGDEGDEGDEGDEGCODESTDDEV0.90.70.70.01.03.04.03.00.05.0MIN2.93.43.457.2~6.35.030.036.054.035.0MAX7'6.86.957.411-1126.0130.0121.056.0129.0j.'ER33B59.9TER150ATER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B 59.959.959.30.00.0'0.60.6F/F/F/F/00PRECIPITATION 1.08INCH00.000.000.00 PRINTOUTPROMGINNAPRIMARYMET.TOWERIBMPCTERMINAL.AV10/8/9209:15RECORDNUMBER3984RG&EGINNAPLANTSENSORNAMEAVERAGEUNITCODESTDDEVMINSPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR2503.83.84.957.37'50.051.452.053.054.0MPH0MPH0MPH0MPH0MPHDEGDEGDEGDEGDEG1.01.01.00.01~119.018.010.00.08.02.07'2'7-12-257.27'57.44.510.09.896.010.093.011.054.090.056.0135.0178.0'VER33ATER33B60.761.2TER150ATER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B 60.760.760.70.00.00.00.5PRECIPITATION 1.08F/F/,~0F/F/0INCH00.000.000.00 PRINTOUTPROMGINNAPRIMARYMET.TOWERIBMPCTERMINALAV,10/8/9209:30RECORDNUMBER3985RG&EGINNAPLANTSENSORNAMEAVERAGEUNITCODESTDDEVMINMAXSPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250'PER33AER33B4.14.25.157.07.450.451.049.052.055.060.760.7MPHMPHMPHMPHMPHDEGDEGDEGDEGDEG00001'1~11~30.41.59.014.014.05.016.02-27.62'7'2'7.556.33'55.057.410.7291.035.0319.0174.0311.054.069.0166.0282.0TER150ATER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B 60.360.360.60.40.40.00.1PRECIPITATION 1.080F/F/0F/0F/0INCH00.000.00,0.00 PRINTOUTPROMGINNAPRIMARYMETTOlifER1BMPCTERMINALAV10/8/9209:45RECORDNUMBER3986RG&EGINNAPLANT8EN80RNAMESPD33ASPD33BSPD150AAVERAGE4.94.84.8UNITMPHMPHMPHCODE0,8TDDEV1~31-21'MIN0.62.01.98.38.28.3SPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR2505.76.949.049.955.056.054.0MPH'PHDEGDEGDEG.DEGDEG0.11-217.014.011.03.010.056.33.697.052.068.057.056.99.5334.0333.08.068.0163.0355.0~ER33ATER33B61.361.6TER150ATER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B 62.062.061.30.70.70.00.4F/F/F/F/PRECIPITATION 1.08INCH00.000.000.00 AVRG&EGINNAPLANT10/8/9210:00RECORDNUMBER3987STDDEV,~MICODEAVERAGESENSORNAMESPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR2509.12.55.01.402.42.556.911.05~11.59.005.21.59.1MPH57.00.057.196.0MPH0MPH6.12.055.040.0DEG013.014.013.0135.058.035.0146.0DEG61'42.0137.0DEG65.0DEG0.53.01.057.046.0134.0069.0DEG12.061.3TER33ATER33B061.7062.5TER150ATER150BTER250A62.661.4F/DT150-33A 1'DT150-33B 1-3DT250-33A 0.1F/0F/DT250-33B -0.4F/PRECIPITATION 1.08INCH00;000.000.00PR1NTOUTPROMGINNAPRIMARYMET+TOWERIBMPCTERMINAL PRXNTOUTPROGINNAPRIMARYMET.TONERBMPCERMXNALAV10/8/921015RECORDNUMBER3988RG&EGINNAPLANTSENSORNAMEAVERAGECODESTDDEVMINSPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150B'DIR250TER33AER33B4.94'4.851.16.680.081.072.054.077.061.361.3MPHMPHMPHMPHDEGDEGDEGDEGDEG01.4~41'0.01.814.013.012.00.010.00.60.50.657.01.030.031.032.053.054.06.96.66.457.19.1141.0146.0139.055.0128.0TER150ATER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B PRECIPITATION 62.062.363.30.72.02.02-11.08FF/F/F/F/0INCH00.000.000.00 PRZNTOUTPROMGZNNAPRZMARYMET~TOWERZBMPCTERMZNALAV10/8/9210:30RECORDNUMBER3989RG&EGINNAPLANTSENSORNAMESPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250TER33AAVERAGE4.84.97.957.+7.881.079.086.053.089.061.3MPHMPHMPHMPHDEGDEGDEGDEGDEGCODE1-3131'0.00.512.01.45.057.00.841.06.97.99.057.29.2140.013.016.00.037.0.148.039.053.0162.054.014.027.0156.0rSTDDEVMZN'AXx'ER33BTER150ATER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B 61.362.262.263.01.01~12'2'F/F/F/F/PRECIPITATION 1.08INCH00.00,0.000.00 PRINTOUTPROMGINNAPRIMARYMETTOWERIBMPCTERMINAL.AV10/8/9210:45RECORDNUMBER3990RG&EGINNAPLANTSENSORNAMESPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250TER33AZER33BAVERAGE5.26.25.557.25.179.077.079.053.077.061.461.4UNITMPHMPHMPHMPHMPHDEGDEGDEGDEGDEGCODE0STDDRV1.01'1'0.01'14.012.09.00.011.0MIN2.88.5F19'2.59.057.157.22.48.235.0139.048.052.032.0122.054.0144.036.0127.0TER150ATER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B 62.562.463.51.0F12-1PRECIPITATION 1.08F/F/F/0F/0INCH00.000.000.00 PRINTOUTFROMGINNAPRIMARYMET4TOWERIBMPCTERMINALAV10/8/9211000RECORDNUMBER3991RGGEGINNAPLANTSENSORNAMEAVERAGEUNITCODE8TDDEVMINSPD33ASPD33B4.85'MPHMPH001.41.41'1.57.47.6SPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250TER33A2.857.25.179'80.079.033.077.062.4MPHMPHMPHDEGDEGDEGDEGDEG000001.60.01'14.014.00.011.01.66.057.157.22.48.228.039.0130.0153.026.0111.032.0144.052.054.0ER33B62.4TER150ATER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B 63.363.364.90.90.92.42.5F/F/F/F/0000PRECIPITATION ,1.08INCH00.000.000.00 PRINTOUTFROMGINNAPRIMARYMET>>TOWERIBMPCTERMINALAV10/8/9211:15RECORDNUMBER3992RG&EGINNAPLANTSENSORNAMESPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250TER33A57'MPH6.8MPH80.0DEG82.0DEG81.0DEG78.0DEG69.0DEG62.5AVERAGEUNITMPHMPHMPHCODESTDDEV1~31-30.01~114.013.013.00.011.0MIN2.4F1MAX10.09.42-29.557.157.33.89.337.0144.039.0133.042.032.0134.0129.041.0120.0'R33BTER150ATER150BTER250A62.563.663.764.9DT150-33A DT150-33B DT250-33A DT250-33B F11~22.42.5PRECIPITATION 1.08F/F/F/0F/0INCH00.000.000.00 PRINTOUTFROMGZNNAPRIMARYMETiTONEIBMPCTERMINALAV10/8/9211:30RECORDNUMBER3993RG&EGINNAPLANTSENSORNAMESPD33A-SPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150B5.65.78.057.26.579.080.079.054.0UNZTMPHMPHMPHMPHMPHDEGDEGDEGDEGCODE0STDDEV-31-22.00.01~311.011.06.00.0MZN2.62.63.057.24.336.037.053.753.08.18.011.057.39.7129.0138.0116.055.0DIR250TER33Al'ER33B78.062.762.7DEG08.020.0125.0TER150ATER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B 63.963.964.81'1'2.52.4F/F/F/F/0PRECIPITATION 1.08INCH0.000.000.00 RINTOUTFROMQINNAPRIMARYMETTOWERIBMPCTERMINALAV10/8/921145RECORDNUMBER3994RG&EGINNAPLANT8EN8ORNAMESPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250TER33Ai'ER33B6.26.46.657.27-276.081.077.053.070.065.065.0MPHMPHMPHMPHMPHDEGDEGDEGDEGDEGCODESTDDEV1.5~41~30.0~1.15.015.017.00.09.0MIN2'2.02.557.13.615.016.021.052.020.0MAX9.89.79.557.310.3115.0114.0125.055.0114.0TER150ATER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B 65.365.566.80.30.51.81.9F/F/F/F/0,PRECIPITATION 1.08INCH00.000.000.00 PRINTOUTFROMGINNAPRIMARYMETTOWERIBMPCTERMINALAV10/8/9212:00RECORDNUMBER.3995RG&EGINNAPLANTSENSORNAMEAVERAGEUNITCODESTDDEVMINSPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250TER33A6.16'6.557.27'77.080.078.053.0~7~065.1MPHMPHMPHMPHDEGDEGDEGDEGDEG01.51.41-30.01.415.015.017.00.09.02-22.02.557.13.615.016.021.052.020.09.89.79.557.310.3115.0114.0125.055.014.0ER33BTER150A65.065.3TER150BTER250A65.566.8DT150-33A DT150-33B DT250-33A DT250-33B PRECIPITATION 0.30.51.81.91.08F/0F/0F/0F/0INCH00.000.000.00 PRINTOUTPROMGINNAPRIMARYMET~TOWERIBMPCTERMINALAV10/8/9212:15RECORDNUMBER3996RGErEGINNAPLANTSENSORNAMESPD33ASPD33B.SPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250TER33A6.5'.6MPHMPH1.51.46.7MPH01~357.2MPH0.07.4MPH1.477.085.079.0DEGDEGDEG15.015.017.0530DEG0.079.0DEG9.066.0AVERAGEUNITCODESTDDEVMIN2'2.02.557.13.615.016.021.052.020.09.89.79.557.310.3115.0114.0125.055.0114.0ER33B66.0TER150ATER150BTER250ADT150-33A DT150-33B DT250-33A 66.366.567.80.40.51.9F/F/F/DT250-33B 1.8PRECIPITATION 1.08F/.0INCH00.000.000.00 PRINTOUT>ROMGZNNAXRZMARVMET.TOWZRIBMPCTERMZNAZ, AV10/8/9212:30RECORDNUMBER3997RG&EGINNAPLANTSENSORNAMESPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR250TER33AER33BAVERAGE8.58'7'57'7.467.065.069.053.069.066.066.0MPH0MPH0MPH0MPH01.41'0.0MPH1.4DEG0.15.0DEGDEG014.015.0DEG0.0DEGF'9.0FUNXTCODESTDDEVMIN2'3.0MAX12.812'2.59.557.13.611.057.310.3104.012.0115.052.020.055.0100.011.0103.0TER150ATER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B 66.366.567.80.40.51.91.8F/F/F/F/000PRECIPITATION 1.08INCH00.000.000.00 PRZNTOUT PROMGZNNAPRZMARYMETTOWERZBMPCTERMZNALAV10/8/9212:45RECORDNUMBER3998RG&EGINNAPLANTSENSORNAMESPD33ASPD33BSPD150ASPD150BSPD250DIR33ADIR33BDIR150ADIR150BDIR2508'87,7~957'7.965.0MPHMPH0'.4MPH01'MPH00.0MPH01.4DEG015.063.0DEG,014.062.0DEG015.053.066.0DEGDEG0.09.0AVERAGEUNITCODESTDDEVMZN2'12.83.012~72.59.557.13.657.310.311.0104.052.055.020.0100.011.0103.0'2.'0 115.0TER33AER33BTER150A'ER150BTER250ADT150-33A DT150-33B DT250-33A DT250-33B 66.066.066.366.567.80.40.51.91.8F/F/F/F/0PRECIPITATION 1.08INCH00.000.000.00 0 SECTlON10.2F!ELDDATAANDMAPS TABLE'10.2PLUME-ARRIVALDEPARTURE TIMESDISTANCEIVII0.51.02.03.04.05.06.07.08.09.010.011.012.0TABLE10.309:2109:2709:3909:5110:0310:1510:2710:3910:5111'0311:1511:2711:39TABLE10.409'4209:4810:0010:1210:2410:3610:4811:0011:1211:2411:3611:4812:0010:0110:0710:1910:3110:4310:5511:0711:1911:3111:4311:5512:0712:19NOTES:"Afterindicated arrivaltime,refertooffsiteradiological datashownonTables10.3and10.4asappropriate forzoneofinterest. Afterindicated departure time,alldoserates(mr/hr)willbebackground. Forgrounddeposition

readings, refertopost-plume radiological datashownonTables10.5and10.6.

TABLE10.3-ARADIOLOGICAL SURVEY/SAMPLING DATA(RG8cEFIELDTEAMS)CLOSEWINDOWOPENWINDOWDOSIMETRY GROSS(mr/hr)(mr/br)INCREMENT IODINEEXPOSURECARTRIDGE ZONE3FEETCONTACT3FEETCONTACT(mREM)(CPM)GROSSPARTIC.FILTER(CPM)A7.33.41.50.70.40.30.20.10.17.33.41.50.70.40.30.20.10.19.54.52.00.90.60.40.20.20.19.54.52.00.90.60.40.20.20.1705045BKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGNOTES:1.DoseratereadingsapplytoVictoreen 450doserateinstrument orequivalent. Ensurethatreadingsprovideddonotexceedrangeofsurveyinstrument beingused.Provideonlythosereadingsbeingrequested, orinaccordance withController instructions. 2.Dosimeter incremental exposureassumesa15-minute stay-time intheparticular zoneofinterest. Incremental valuesmaybescaledupordownasappropriate. Providecumulative dosimeter readingonlywhenrequested. 3.AirsamplesassumeuseofRADECOH-809Cairsamplerorequivalent. Volumeassumedisapproximately 180liters(30Ipmfor6minutes), andfieldreadingiswithHP-260,4.BKG=Useactualbackroundreadinofsurveinstrument beinused.lo-3Y I~IJl'%g'4 TABLE10.3-BRADlOLOGICAL SURVEY/SAMPL(NG:DATA (COUNTYTEAMS)CLOSEWINDOWOPENWINDOWDOSIMETRY GROSS(mr/hr)(mr/hr)INCREMENT IODINEEXPOSURECARTRIDGE ZONE3FEETCONTACT3FEETCONTACT(mREM)(CPM)GROSSPARTIC.FILTER(CPM)7.33.47.33.49.54.59.54.59060BKGBKG1.50.70.41.50.70.42.02.00.9"0.90.60.650BKGBKGBKGBKGBKG0.30.20.10.10.30.20.10.10.40.20.20.10.40.20.20.1BKGBKGBKGBKGBKGBKGBKGBKGNOTES:1.DoseratereadingsapplytoVictoreen 450,CDV-715,RO-2doserateinstrument orequivalent. Ensurethatreadingsprovideddonotexceedrangeofsurveyinstrument beingused.Provideonlythosereadingsbeingrequested, orinaccordance withController instructions. 2.Dosimeter incremental exposureassumesa15-minute stay-time intheparticular zoneofinterest. Incremental valuesmaybescaledupordownasappropriate. Providecumulative dosimeter readingonlywhenrequested. 3.AirsamplesassumeuseofRADECOH-809Cairsamplerorequivalent. Volumeassumedisapproximately 10cubicfeet,andfieldreadingiswithHP-260orequivalent. 4.BKG=Useactualbackroundreadinofsurveinstrumen beinused. ~P%PtI.via'4t4,'f>)tc",~s"M TABL'E10.4-ARADIOLOGICAL SURVEY/SAMPLING DATA(RGEEESURVEYTEAMS)CLOSEWINDOWOPENWINDOWDOSIMETRY GROSS(mr/hr)'mr/hr) INCREMENT IODINEEXPOSURECARTRIDGE ZONE3FEETCONTACT3FEETCONTACT(mREM)(CPM)GROSSPARTIC.FILTER(CPM)0.90.9BKGBKG0.40.40.20.20.50.20.50.2BKGBKGBKGBKG0.10.10.10.1BKGBKGBKGBKGBKGBKG0BKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKG-BKGBKGBKGBKGNOTES:1.:DoseratereadingsapplytoVictoreen 450doserateinstrument orequivalent. Ensurethatreadingsprovideddonotexceedrangeofsurveyinstrument beingused.Provideonlythosereadingsbeingrequested, orinaccordance withController instructions. 2.Dosimeter incremental exposureassumesa15-minute stay-time intheparticular zoneofinterest. Incremental valuesmaybescaledupordownasappropriate. Providecumulative dosimeter readingonlywhenrequested. 3.AirsamplesassumeuseofRADECOH-809Cairsamplerorequivalent. Volumeassumedisapproximately 180liters(30lpmfor6minutes), andfieldreadingiswithHP-260.4.BKG=Useacualbackroundreadinofsurveinstrumen beinused. J')IIr<<~'IfI TABLE10.4-BRADIOLOGICAL SURVEY/SAMPLING DATA(COUNTYTEAMS)CLOSEWINDOWOPENWINDOWDOSIMETRY GROSS(mr/hr)(mr/br)INCREMENT IODINEEXPOSURECARTRIDGE ZONE3FEETCONTACT3FEETCONTACT(mREM)(CPM)GROSSPARTIC.FILTER(CPM)0,90.40.20.1BKGBKGBKGBKGBKG0.90.40.20.1BKGBKGBKGBKGBKG0.50.20.1BKGBKGBKGBKGBKG0.50.20.1BKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGNOTES:1.DoseratereadingsapplytoVictoreen 450,CDV-715,RO-2doserateinstrument orequivalent. Ensurethatreadingsprovideddonotexceedrangeofsurveyinstrument beingused.Provideonlythosereadingsbeingrequested, orinaccordance withController instructions. 2~Dosimeter incremental exposureassumesa15-minute stay-time intheparticular zoneofinterest. Incremental valuesmaybescaledupordownasappropriate. Providecumulative dosimeter readingonlywhenrequested. 3.AirsamplesassumeuseofRADECOH-809Cairsamplerorequivalent. Volumeassumedisapproximately 10cubicfeet,andfieldreadingiswithHP-260orequivalent. 4.BKG=Useactualbackroundreadinofsurveinstrument beinsed. I1! TABLE10.5POST-PLUME SURVEYDATA(FORPANCAKEPROBESANDRM-14METER)ZONEAPANCAKEPROBE(GROSSCPM)1METERBKGBKGBKGBKGBKGBKGBKGBKGBKG1CMBKGBKGBKGBKGBKGBKGBKGBKGBKGNOTE:BKG=Useacualbackroundreadinofsurveinsrurnenbeinused. ~l~ TABLE10.6POST-PLUME SURVEYDATA(GAMMAMICRO-R/HOUR READINGS) ZONEGROSSGROSSMICRO-R/HOUR MICRO-R/HOUR @1METER91CMADGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGBKGNOTE:BKG=Useactualbackroundreadinofsurveinstrumen beinsed.Io-3g ri-~e4I~a><t SECTION10.3FIELDAIRSAIVIPLEISOTOPICDATA Sr'I,iP~ihjI)~l+>,"'I1,.lIIli,I~~tf0i,i~~a~)'lr('A~!,-I TABLE10.7-AAIRPARTICULATE FILTERISOTOPICACTIVITYSAHPLECOLLECTION DURINGPLUHEPHASECOUNTYTEAHS.10CUBICFTSAHPLETOTALFIELDI-131I-133I-135CS-13420NEACTIVITYREADINGUCI/CC(CPH)UCI/CCUCI/CCUCI/CCUCI/CCCS-137BA-140LA-140UCI/CCUCI/CCUCI/CC6.71E-112.98E-111.33E-116.23E-123.83E-122.52E-121.61E-121.15E-129.10E-134.6E+014.2E+014.1E+014.1E+014.DE+014.DE+014'E+014.DE+014.0E+011.99E-118.85E-123.96E-121.85E-121.14E-127.47E-134.77E-133.42E-132.70E-131.39E.116.20E-122.77E-121.29E-127.95E-135.23E-133.34E-132.40E-131.89E-137.96E-123.54E-'l2 1.58E-127.39E-134.55E-132.99E-131.91E-131.37E-131.08E-13O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.OOE+00O.DOE+00O.DOE+00O.OOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+000.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00O.DOE+00TABLE10.7-BSILVER2EDLITECARTRIDGE RADIOIODINE ISOTOPICACTIVITYSAHPLECOLLECTION DURINGPLUHEPHASECOUNTYTEAHS-10CUBICFl'AHPLETOTALFIELDI-131I-132I-133I-134I-135ZONEACTIVITYREADINGUCI/CC(CPH)UCI/CCUCI/CCUCI/CCUCI/CCUCI/CC6.71E-092.98E-091.33E-096.23E-103.83E-102.52E-101.61E101.15E-109.10E.118.5E+016.DE+014.9E+014.4E+014.3E+014.2E+014.1E+014.1E+014.1E+011.99E-098.85E-103.96E-101.85E-101.14E-107.47E-114.77E-113.42E-112.70E-113.39E-101.50E-106.73E-113.14E-111.93E-111.27E-118.10E-125.82E-124.59E-121.39E-096.20E-102.77E-101.29E-107.95E-115.23E-113.34E-112.40E-111.89E-112.19E-099.74E-104.35E-102.03E-101.25E-108.21E-115~24E-113.76E-112.97E-117.96E-103.54E-101.58E-107.39E-114.55E-112.99E-111.91E-111.37E-111.08E-11 ~ClPV]p4.1rIl444~ll~ll44~M~44OAT,;!'1'e-t ~~l~l~~~~M~~~)r"r4'4!i'4V,~,~~lftVpr".,(4I~4lIlI,~c~~t,J'I't,.;J(ly'44ll,I~.<<~lf~4It44~4'4rf',C1y4"-~~~lWly~lyl FIGURE40.2PLUMEMAP.(0"O'!LE)RC.CL~tLAÃ2SAX0~~pl~~SCCQSI5VTDCC~1aaaLaaasuaaTATION 154I0RIR~WVOC.aDO.SNllR gIlpf--l,<~';=.:.-~...: ..;4).-,.' 'hll)~i~~~I~i'htf!IIW\<'<'0IIt'tt,...~hIhrr'trI-~-~Ithttrij'"dii:~hItIIChth~h'p~I'I/r~!p'~IIgt'EI,,~illp+~~-.'*:;-~-..:.--,.":8..:=,,~-~~-'h~a.'~,'l~,t'..-',;;IIh/+IIIj\~~~~hhtI~~'t ~-~~~~gle-(I(IIinf41$tentMIINMIIll~IPss),-.'49foalf/Ski""0+,~R%0ai'~).)%i4~1tlK8 1}}