ML20066D266
ML20066D266 | |
Person / Time | |
---|---|
Site: | Browns Ferry |
Issue date: | 11/03/1982 |
From: | Mills L TENNESSEE VALLEY AUTHORITY |
To: | Harold Denton Office of Nuclear Reactor Regulation |
Shared Package | |
ML20066D268 | List: |
References | |
NUDOCS 8211110257 | |
Download: ML20066D266 (2) | |
Similar Documents at Browns Ferry | |
---|---|
Category:OPERATING LICENSES-APPLIATION TO AMEND-RENEW EXISTING
MONTHYEARML18039A8871999-09-30030 September 1999
[Table view]Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, to Update TS License Conditions.Ts Change TS-381,consists of Administrative Revs That Delete License Conditions That Have Become Outdated,No Longer Applicable or Are Redundant ML18039A8781999-09-28028 September 1999 TS Change 399 to Licenses DPR-52 & DPR-68,increasing Allowable Leakage Rate Criteria for MSIVs & Requesting Exemption to Portions of 10CFR50,App J.Rev 0 to Rept 2100918-R-002 Encl ML18039A8221999-07-28028 July 1999 TS Change 398 to License DPR-58,providing TS for Operation of Oscillation PRM Upscale Trip Function in Aprm,Which Is Part of Power Range Neutron Monitoring Sys ML18039A7981999-06-0303 June 1999 Application for Amends to Licenses DPR-52 & DPR-68,reducing Allowable Value Used for Reactor Vessel Water Level - Low, Level 3 for Several Instrument Functions ML20196A9491998-11-19019 November 1998 Suppl 1 to 970602 Application for Amends to Licenses DPR-33, DPR-52 & DPR-68,allowing Continued Plant Operation with Single Recirculation Loop in Svc ML18039A5011998-09-0808 September 1998 TS Change 354 to License DPR-52,providing TS for Operation of Oscillation Power Range Monitor Upscale Trip Function in Aprm,Which Is Part of Power Range Neutron Monitoring Sys ML18039A4981998-09-0404 September 1998 Application for Amends to Licenses DPR-52 & DPR-68,amending Use of Containment Overpressure for ECCS Pump Net Positive Suction Head Analyses,Per NRC Bulletin 96-003 ML18039A4771998-08-14014 August 1998 Supplemental Application for Amends to Licenses DPR-33, DPR-52 & DPR-68 to Change TSs for Instrument Calibration Surveillance Frequencies.Proposed Changes Decrease Frequency of once-per-cycle by Substituting 24 Months for 18 Months ML18039A4071998-06-26026 June 1998 Application for Amends to Licenses DPR-52 & DPR-68,revising TS Section 3.4, Rcs. ML18039A3901998-06-12012 June 1998 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Decreasing Frequency of once-per-cycle SRs by Substituting 24 Months for 18 Months in Affected TS SRs ML20249A5641998-06-10010 June 1998 Supplemental Application for Amend to Licenses DPR-33,DPR-52 & DPR-68,revising ITS Section 5.0 Re Administrative Controls ML18039A2691998-03-16016 March 1998 Suppl 1 to TS Change 384 to Licenses DPR-52 & DPR-68, Allowing Units 2 & 3 to Operate at Uprated Power of 3458 Mwt Representing Power Level Increase of Five Percent ML18039A2591998-03-0303 March 1998 Application for Amends to Licenses DPR-52 & DPR-68,revising TS 393 Re pressure-temperature Curve Update ML18039A2201997-12-30030 December 1997 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Consisting of TS Change 395,removing non-conservatism Associated W/Lco 3.5.C, RHR Svc Water & Eecw. ML18038B9581997-10-0101 October 1997 Application for Amends to Licenses DPR-52 & DPR-68, Consisting of TS Change 384,allowing Bfn,Units 2 & 3,to Operate at Uprated Power Level of 3458 Mwt.Proprietary Rept Re Power Uprate Safety Analysis,Also Encl.Rept Withheld ML18038B9041997-06-19019 June 1997 Application for Amends to Licenses DPR-52 & DPR-68, Requesting Temporary TS Change to Provide one-time 14-day Limiting Condition for Operation for Each EDG to Accommodate Pending Vendor Recommended Maint Activities ML20137U1081997-04-11011 April 1997 Suppl 1,TS Change 353S1 to Licenses DPR-33,DPR-52 & DPR-68, Revising Existing Custom for Units to Include Changes Associated W/Implementation of Pr Neutron Monitor Upgrade & to Incorporate Changes ML18038B8321997-03-12012 March 1997 Application for Amends to Licenses DPR-52 & DPR-68, Consisting of TS Change 376,extending EDG Allowed Outage Time ML20132B7301996-12-11011 December 1996 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Consisting of TS-386,increasing TS 2.2.A Re Safety/Relief Valve Setpoint Requirements for Reactor Coolant Sys Integrity.Rev 3 to J11-02761SRLR Rept Encl ML20117P3311996-09-15015 September 1996 Application for Amend to License DPR-68 to Change Unit 3 TS LCO 3.6.F.1 in Order to Perform Repairs & Maint Necessary to Return RCS Recirculation Loop a to Operations ML20117G7081996-08-30030 August 1996 Application for Amend to Licenses DPR-33,DPR-52 & DPR-68, Eliminating License Condition 2.C.(3) on Thermal Water Quality Stds ML20113B1851996-06-21021 June 1996 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Revising SLMCPR & Bases Description of RHR Removal Suppl Fuel Pool Cooling Mode ML20112G3811996-06-0606 June 1996 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Revising Section 6, Administrative Controls, to Be More Closely Aligned W/Requirements of Improved Std TSs ML20117H5131996-05-20020 May 1996 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Consisting of TS Change 373,revising TS to Implement Guidance of GL 87-09 & NUREG-1433,Rev 1 ML20108D8911996-05-0303 May 1996 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Withdrawing Amend 219,temporary TS 343T,RV Water Level Instrumentation & Amend 228,temporary TS 347T,250 Volt DC Control Power Supply Sys AOT for Unit 2 Only ML20107F9591996-04-14014 April 1996 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Respectively,Revising Minimum Required Number of Operable Rv Water Level Trip Sys During Period That RCS Instrument Line Excess Flow Check Valve Surveillance Tests Being Performed ML20096C4341996-01-10010 January 1996 Suppl to TS Change Request 364 to Licenses DPR-33,DPR-52 & DPR-68,revising TS to Implement 10CFR50,App J,Option B, Performance Based Testing.Suppl Incorporates Word Door to Note in SR 4.7.A.2.g.Corrected TS Encl ML20095E4051995-12-0808 December 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Consisting of Proposed TS Change TS-364,revising TS Section 4.7.A to Implement Recent Rule Change to 10CFR50,App J to Incorporate Option B for Containment Leak Rate Testing ML20093B0451995-10-0202 October 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Revising TS-371 Bases Sections 3.5.A & 3.5.B, Core Spray Sys & Residual Heat Removal Sys & 3.5.C, RHR Svc Water & Emergency Equipment Cooling Water Sys ML20092F3191995-09-13013 September 1995 Application for Amend to License DPR-68 Changing TS Table 4.2.B & 4.2.C to Delete Requirements to Perform Daily Instrument Checks for Steam Supply Low Pressure & Turbine Exhaust Diaphragm High Pressure ML20086G6951995-07-10010 July 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68 Revising TS Base Section 3.7.A/4.7.A to Clarify Method of Determining Operability of Drywell to Suppression Chamber Vacuum Breakers ML20085K4731995-06-16016 June 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Revising TS to Allow TIP Sys to Be Considered Operable W/ Less than Five TIP Machines Operable ML20084T9631995-06-0202 June 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Clarifying Definition of Operability for RHRSW Sys Standby Coolant Supply Capability & Revising Instrument Numbers in Tables 3.2.F & 4.2.F for Instruments Upgraded ML20085D5891995-06-0202 June 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Revising TS to Be Consistent W/Planned Replacement of Current Power Range Monitoring Portion of Existing Nms,Per GL 94-02.Proprietary GE Rept NEDC-32433P Encl.Rept Withheld ML20083M0351995-05-11011 May 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Reflecting Interim Addition of Scram Pilot Air Header Low Pressure Trip Function on Unit 3 ML20080J2771995-02-23023 February 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Revising TS-348 Re Residual Heat Removal Sys Interlock Installation ML20077K2171995-01-0404 January 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Proposing Changes to Ts,By Revising Applicability & SR for Irm,Aprm High Flux (15% Scram) & APRM Inoperative Trip Functions ML20077A5081994-11-15015 November 1994 Application for Amends to Licenses DPR-33,DPR-52,DPR-68, DPR-77 & DPR-79,deleting Audit Frequencies & Requirement to Perform Radiological Emergency Plan & Security Plan Audits from TSs ML20149G2391994-10-0707 October 1994 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Revising Surveillance Requirements for Plant Operation W/ Inoperable Diesel Generator ML18037A8741994-05-11011 May 1994 Application for Amend to License DPR-52,consisting of TS Change TS-347T to Temporarily Extend AOT of TS 3.9.B.8 While TVA Replaces Batteries & Associated Hardware That Supply 250 Volt Dc Control Power to Units 1 & 2 Shutdown Boards ML20065H2201994-04-0404 April 1994 Suppl 1 to TS-322 to Licenses DPR-33,DPR-52 & DPR-68, Eliminating Reactor Scram & Main Steam Line Isolation Functions Associated W/Msl Radiation Monitors ML20065E3651994-03-31031 March 1994 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Extending Load Line Limit & Revising Rod Block Monitor Operability Requirements & Deleting Specific Value for Rated Reactor Loop Recirculation Flow Rate ML20065F2511994-03-31031 March 1994 Request for Amend TS-319 to Licenses DPR-33 & DPR-68, Lowering Trip Level Settings for HPCI & RCIC Steam Line Space Isolation Instrument Channels ML20065E3841994-03-30030 March 1994 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Revising TSs Re Analog Transmitter/Trip Sys,Level 1 Reactor Water Level Setpoint & Various Calibr Frequencies ML20065D4931994-03-29029 March 1994 Request for Amend TS-340 to License DPR-68,revising TS to Add Operability & SRs to Support Unit 3 480-volt Load Shed Logic Sys Being Added by Design Change ML20059C4981993-12-23023 December 1993 TS Change 346 to Licenses DPR-33,DPR-52 & DPR-68, Incorporating Recommendations for Snubber Visual Insp Intervals Contained in GL 90-09, Alternative Requirements for Snubber Visual Insp Intervals & Corrective Actions ML20057G2511993-10-12012 October 1993 Request for Amend TS-320 to Licenses DPR-33,DPR-52 & DPR-68, Deleting Existing RWCU Sys High Temp Detection Switches from Tables 3.2.A & 4.2.A & Adding New RWCU Sys Temp Loops for Unit 3 & Clarifying Tables 3.2.A & 3.2.B for Units 1,2 & 3 ML20057E8621993-10-0707 October 1993 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Consisting of TS 313,adding High Range Primary Containment RMs & Recorders to Tables 3.2.F,4.2.F & TS Section 6.9.2 in Response to NUREG-0737,Item II.F.1.3 ML18037A4761993-09-30030 September 1993 Request for Amend TS-312 to Licenses DPR-33,DPR-52 & DPR-68, Removing SDV Air Header Pressure Trip Switches Scram Function from Unit 2 TS & Clarifying Description of SDV High Water Level Bypass in RPS for Units 1,2 & 3 ML18037A4801993-09-30030 September 1993 Requests for Amend TS-336 to Licenses DPR-33,DPR-52 & DPR-68,revising & Clarifying Spent Fuel Pool Water Level, Temp & Sampling & Analysis Srs,In Ref to Insp Repts 50-259/93-07,50-260/93-07 & 50-296/93-07 1999-09-30 Category:TEXT-LICENSE APPLICATIONS & PERMITS MONTHYEARML18039A8871999-09-30030 September 1999
[Table view]Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, to Update TS License Conditions.Ts Change TS-381,consists of Administrative Revs That Delete License Conditions That Have Become Outdated,No Longer Applicable or Are Redundant ML18039A8781999-09-28028 September 1999 TS Change 399 to Licenses DPR-52 & DPR-68,increasing Allowable Leakage Rate Criteria for MSIVs & Requesting Exemption to Portions of 10CFR50,App J.Rev 0 to Rept 2100918-R-002 Encl ML18039A8221999-07-28028 July 1999 TS Change 398 to License DPR-58,providing TS for Operation of Oscillation PRM Upscale Trip Function in Aprm,Which Is Part of Power Range Neutron Monitoring Sys ML18039A7981999-06-0303 June 1999 Application for Amends to Licenses DPR-52 & DPR-68,reducing Allowable Value Used for Reactor Vessel Water Level - Low, Level 3 for Several Instrument Functions ML20196A9491998-11-19019 November 1998 Suppl 1 to 970602 Application for Amends to Licenses DPR-33, DPR-52 & DPR-68,allowing Continued Plant Operation with Single Recirculation Loop in Svc ML18039A5011998-09-0808 September 1998 TS Change 354 to License DPR-52,providing TS for Operation of Oscillation Power Range Monitor Upscale Trip Function in Aprm,Which Is Part of Power Range Neutron Monitoring Sys ML18039A4981998-09-0404 September 1998 Application for Amends to Licenses DPR-52 & DPR-68,amending Use of Containment Overpressure for ECCS Pump Net Positive Suction Head Analyses,Per NRC Bulletin 96-003 ML18039A4771998-08-14014 August 1998 Supplemental Application for Amends to Licenses DPR-33, DPR-52 & DPR-68 to Change TSs for Instrument Calibration Surveillance Frequencies.Proposed Changes Decrease Frequency of once-per-cycle by Substituting 24 Months for 18 Months ML18039A4071998-06-26026 June 1998 Application for Amends to Licenses DPR-52 & DPR-68,revising TS Section 3.4, Rcs. ML18039A3901998-06-12012 June 1998 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Decreasing Frequency of once-per-cycle SRs by Substituting 24 Months for 18 Months in Affected TS SRs ML20249A5641998-06-10010 June 1998 Supplemental Application for Amend to Licenses DPR-33,DPR-52 & DPR-68,revising ITS Section 5.0 Re Administrative Controls ML18039A2691998-03-16016 March 1998 Suppl 1 to TS Change 384 to Licenses DPR-52 & DPR-68, Allowing Units 2 & 3 to Operate at Uprated Power of 3458 Mwt Representing Power Level Increase of Five Percent ML18039A2591998-03-0303 March 1998 Application for Amends to Licenses DPR-52 & DPR-68,revising TS 393 Re pressure-temperature Curve Update ML18039A2201997-12-30030 December 1997 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Consisting of TS Change 395,removing non-conservatism Associated W/Lco 3.5.C, RHR Svc Water & Eecw. ML18038B9581997-10-0101 October 1997 Application for Amends to Licenses DPR-52 & DPR-68, Consisting of TS Change 384,allowing Bfn,Units 2 & 3,to Operate at Uprated Power Level of 3458 Mwt.Proprietary Rept Re Power Uprate Safety Analysis,Also Encl.Rept Withheld ML20217C2111997-09-11011 September 1997 Amend 249 to License DPR-52,providing Changes Required to Implement Improved Power Range Neutron Monitor Sys, Designated by Licensee as Group a Changes ML18038B9041997-06-19019 June 1997 Application for Amends to Licenses DPR-52 & DPR-68, Requesting Temporary TS Change to Provide one-time 14-day Limiting Condition for Operation for Each EDG to Accommodate Pending Vendor Recommended Maint Activities ML20137U1081997-04-11011 April 1997 Suppl 1,TS Change 353S1 to Licenses DPR-33,DPR-52 & DPR-68, Revising Existing Custom for Units to Include Changes Associated W/Implementation of Pr Neutron Monitor Upgrade & to Incorporate Changes ML18038B8321997-03-12012 March 1997 Application for Amends to Licenses DPR-52 & DPR-68, Consisting of TS Change 376,extending EDG Allowed Outage Time ML20132B7301996-12-11011 December 1996 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Consisting of TS-386,increasing TS 2.2.A Re Safety/Relief Valve Setpoint Requirements for Reactor Coolant Sys Integrity.Rev 3 to J11-02761SRLR Rept Encl ML20117P3311996-09-15015 September 1996 Application for Amend to License DPR-68 to Change Unit 3 TS LCO 3.6.F.1 in Order to Perform Repairs & Maint Necessary to Return RCS Recirculation Loop a to Operations ML20117G7081996-08-30030 August 1996 Application for Amend to Licenses DPR-33,DPR-52 & DPR-68, Eliminating License Condition 2.C.(3) on Thermal Water Quality Stds ML20113B1851996-06-21021 June 1996 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Revising SLMCPR & Bases Description of RHR Removal Suppl Fuel Pool Cooling Mode ML20112G3811996-06-0606 June 1996 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Revising Section 6, Administrative Controls, to Be More Closely Aligned W/Requirements of Improved Std TSs ML20117H5131996-05-20020 May 1996 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Consisting of TS Change 373,revising TS to Implement Guidance of GL 87-09 & NUREG-1433,Rev 1 ML20108D8911996-05-0303 May 1996 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Withdrawing Amend 219,temporary TS 343T,RV Water Level Instrumentation & Amend 228,temporary TS 347T,250 Volt DC Control Power Supply Sys AOT for Unit 2 Only ML20107F9591996-04-14014 April 1996 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Respectively,Revising Minimum Required Number of Operable Rv Water Level Trip Sys During Period That RCS Instrument Line Excess Flow Check Valve Surveillance Tests Being Performed ML20096C4341996-01-10010 January 1996 Suppl to TS Change Request 364 to Licenses DPR-33,DPR-52 & DPR-68,revising TS to Implement 10CFR50,App J,Option B, Performance Based Testing.Suppl Incorporates Word Door to Note in SR 4.7.A.2.g.Corrected TS Encl ML20095E4051995-12-0808 December 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Consisting of Proposed TS Change TS-364,revising TS Section 4.7.A to Implement Recent Rule Change to 10CFR50,App J to Incorporate Option B for Containment Leak Rate Testing ML20093B0451995-10-0202 October 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Revising TS-371 Bases Sections 3.5.A & 3.5.B, Core Spray Sys & Residual Heat Removal Sys & 3.5.C, RHR Svc Water & Emergency Equipment Cooling Water Sys ML20092F3191995-09-13013 September 1995 Application for Amend to License DPR-68 Changing TS Table 4.2.B & 4.2.C to Delete Requirements to Perform Daily Instrument Checks for Steam Supply Low Pressure & Turbine Exhaust Diaphragm High Pressure ML20086G6951995-07-10010 July 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68 Revising TS Base Section 3.7.A/4.7.A to Clarify Method of Determining Operability of Drywell to Suppression Chamber Vacuum Breakers ML20085K4731995-06-16016 June 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Revising TS to Allow TIP Sys to Be Considered Operable W/ Less than Five TIP Machines Operable ML20084T9631995-06-0202 June 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Clarifying Definition of Operability for RHRSW Sys Standby Coolant Supply Capability & Revising Instrument Numbers in Tables 3.2.F & 4.2.F for Instruments Upgraded ML20085D5891995-06-0202 June 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Revising TS to Be Consistent W/Planned Replacement of Current Power Range Monitoring Portion of Existing Nms,Per GL 94-02.Proprietary GE Rept NEDC-32433P Encl.Rept Withheld ML20083M0351995-05-11011 May 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Reflecting Interim Addition of Scram Pilot Air Header Low Pressure Trip Function on Unit 3 ML20080J2771995-02-23023 February 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Revising TS-348 Re Residual Heat Removal Sys Interlock Installation ML20077K2171995-01-0404 January 1995 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Proposing Changes to Ts,By Revising Applicability & SR for Irm,Aprm High Flux (15% Scram) & APRM Inoperative Trip Functions ML20077A5081994-11-15015 November 1994 Application for Amends to Licenses DPR-33,DPR-52,DPR-68, DPR-77 & DPR-79,deleting Audit Frequencies & Requirement to Perform Radiological Emergency Plan & Security Plan Audits from TSs ML20149G2391994-10-0707 October 1994 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Revising Surveillance Requirements for Plant Operation W/ Inoperable Diesel Generator ML18037A8741994-05-11011 May 1994 Application for Amend to License DPR-52,consisting of TS Change TS-347T to Temporarily Extend AOT of TS 3.9.B.8 While TVA Replaces Batteries & Associated Hardware That Supply 250 Volt Dc Control Power to Units 1 & 2 Shutdown Boards ML20065H2201994-04-0404 April 1994 Suppl 1 to TS-322 to Licenses DPR-33,DPR-52 & DPR-68, Eliminating Reactor Scram & Main Steam Line Isolation Functions Associated W/Msl Radiation Monitors ML20065E3651994-03-31031 March 1994 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Extending Load Line Limit & Revising Rod Block Monitor Operability Requirements & Deleting Specific Value for Rated Reactor Loop Recirculation Flow Rate ML20065F2511994-03-31031 March 1994 Request for Amend TS-319 to Licenses DPR-33 & DPR-68, Lowering Trip Level Settings for HPCI & RCIC Steam Line Space Isolation Instrument Channels ML20065E3841994-03-30030 March 1994 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Revising TSs Re Analog Transmitter/Trip Sys,Level 1 Reactor Water Level Setpoint & Various Calibr Frequencies ML20065D4931994-03-29029 March 1994 Request for Amend TS-340 to License DPR-68,revising TS to Add Operability & SRs to Support Unit 3 480-volt Load Shed Logic Sys Being Added by Design Change ML20059C4981993-12-23023 December 1993 TS Change 346 to Licenses DPR-33,DPR-52 & DPR-68, Incorporating Recommendations for Snubber Visual Insp Intervals Contained in GL 90-09, Alternative Requirements for Snubber Visual Insp Intervals & Corrective Actions ML20057G2511993-10-12012 October 1993 Request for Amend TS-320 to Licenses DPR-33,DPR-52 & DPR-68, Deleting Existing RWCU Sys High Temp Detection Switches from Tables 3.2.A & 4.2.A & Adding New RWCU Sys Temp Loops for Unit 3 & Clarifying Tables 3.2.A & 3.2.B for Units 1,2 & 3 ML20057E8621993-10-0707 October 1993 Application for Amends to Licenses DPR-33,DPR-52 & DPR-68, Consisting of TS 313,adding High Range Primary Containment RMs & Recorders to Tables 3.2.F,4.2.F & TS Section 6.9.2 in Response to NUREG-0737,Item II.F.1.3 ML18037A4761993-09-30030 September 1993 Request for Amend TS-312 to Licenses DPR-33,DPR-52 & DPR-68, Removing SDV Air Header Pressure Trip Switches Scram Function from Unit 2 TS & Clarifying Description of SDV High Water Level Bypass in RPS for Units 1,2 & 3 1999-09-30 |
Text
.
o TENNESSEE VALLEY AUTHORITY CHATTANOOGA. TENNESSEE 374o1 400 Chestnut Street Tower II November 3, 1982 TVA BFNP TS 144 SUPPLEMENT 1 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555
Dear Mr. Denton:
In the Matter of the ) Docket Nos. 50-259 Tennessee Valley Authority ) 50-260 50-296 By my letter to you dated August 12, 1980 we submitted a request for technical specification change, TVA BFNP TS 144, for the Browns Ferry Nuclear Plant. That request proposed to change several isolation functions to an alarm function. After several discussions with your staff, we have decided to submit a revised request as a supplement to TS 144. The proposed technical specification revisions are provided as Enclosure 1 and justification for the changes is provided as Enclosure P.
The proposed specifications allow operation for up to 30 days with one temperature switch in the main steam tunnel inoperable. We understand from discussions with R. J. Clark of your staff that this 30-day operability period has already been accepted and endorsed by the NRC staff. Approval of the enclosed specifications will constitute complete approval and close out of TS 144.
Because the enclosed specifications are only a minor revision to TS 14h and have already been essentially approved, we do not believe any NRC staff review is needed. Furthermore, fees totaling $4,800 were forwarded with TS 144. Accordingly, we do not believe additional recs are appropriate and none are being forwarded. This has been discussed with R. J. Clark.
Very truly yours, ENNESSEE VALLEY AUTHORITY 8211110257 821103 DR ADOCK 05000 k L. M. Mills, Panager Nuclear Licensing Subscribe an sworn to ore 00l this day of fW- 1982.
- t$ dA L S A A d s Not y Public
~ "
g My Commission Expires h. I, .
Enclosures cc: See page 2 An Equal Opportunity Employer
e Mr.'Hetold R. Denton November 3, 1982 cc (Enclosures):
Mr. Charles R. Christopher Chairman, Limestone County Commission P.O. Box 188 Athens, Alabama 35611 Dr. Ira L. Myers State Health Officer State Department of Public Health State Office Bitilding Montgomery, Alabama 36104 Mr. R. J. Clark Browns Ferry Project Manager U.S. Nuclear Regulatory Commission 7920 Norfolk Avenue Bethesda, Maryland 20814 l
__. _- . _ . .