{{#Wiki_filter:Appendix C Job Performance Measure Form ES-C- | {{#Wiki_filter:Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2090501403/2090504401 Task Title: Align the Core Spray System to the Condensate Storage Tank for Emergency Operations Job Performance Measure No: NRC Plant1 (RO/SRO) | ||
K/A | K/A | ||
==Reference:== | ==Reference:== | ||
295030 G2.1.30 (RO 3.7/SRO 4.4)Examinee: | 295030 G2.1.30 (RO 3.7/SRO 4.4) | ||
Facility Evaluator: | Examinee: ___________________ NRC Examiner: ___________________ | ||
Method of Testing:Simulated Performance | Facility Evaluator: ___________________ Date: _________ | ||
Method of Testing: | |||
Simulated Performance X Actual Performance ________________ | |||
Classroom _________ Simulator _________ Plant X Read to the Examinee: | |||
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied. | |||
Initial Conditions: | |||
: 1. The Reactor is shutdown. | |||
: 2. Reactor water level is being maintained at 160 inches with feedwater. | |||
: 3. Drywell pressure is 1.1 psig and stable. | : 3. Drywell pressure is 1.1 psig and stable. | ||
: 4. Torus water level is 140 inches and lowering due to a leak. | : 4. Torus water level is 140 inches and lowering due to a leak. | ||
: 5. The Reactor Building is accessible. | : 5. The Reactor Building is accessible. | ||
: 6. Core Spray System 1 is operable and available.Task Standard:Making-up to the Torus from the CST via Core Spray System 1 in accordance with Support Procedure 37. | : 6. Core Spray System 1 is operable and available. | ||
Task Standard: Making-up to the Torus from the CST via Core Spray System 1 in accordance with Support Procedure 37. | |||
Required Materials: MB-1 and PA-2235 keys (simulated) | Required Materials: MB-1 and PA-2235 keys (simulated) | ||
Appendix C Job Performance Measure Form ES-C- | NRC Plant1 Page 1 of 8 | ||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET General | |||
==References:== | ==References:== | ||
Support Procedure 37 of EMG-3200.02, | Support Procedure 37 of EMG-3200.02, Primary Containment Control, Rev. 17 Initiating Cue: Line up and add makeup to the torus from the CST via Core Spray System 1 in accordance with Support Procedure 37. | ||
Time Critical Task: | Time Critical Task: No Validation Time: 40 minutes NRC Plant1 Page 2 of 8 | ||
Standard: Provides repeat | |||
Evaluator acknowledges repeat back. | Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: __________ | ||
Comment: | Standard: Provides repeat back of initiating cue. Evaluator acknowledges repeat back. | ||
Comment: | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
Performance Step: 2 Standard: Verifies Prerequisites. | |||
Comment: | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
Performance Step: | NRC Plant1 Page 3 of 8 | ||
Comment: | |||
Appendix C Form ES-C-1 Performance Information Performance Step: 3 (step 3.2.4.1) | |||
CUE: Report that the following steps have been completed: | |||
* System 1 Core Spray Main Pumps and Booster Pumps are stopped (step 3.2.1) | |||
* Core Spray System suction valves V-20-3 and V-20-32 are closed (step 3.2.2) | |||
* Core Spray System 1 Parallel Isolation valves V-20-15 and V-20-40 are closed (step 3.2.3) | |||
Standard: Places the Core Spray pump suction valve breakers in OFF: | |||
* V-20-3 (MCC 1A21A RB 23 SW) | |||
* V-20-32 (MCC 1B21A RB 23 NE) | |||
Appendix C Form ES-C- | |||
CUE: Report that the following steps have been completed: System 1 Core Spray Main Pumps and Booster Pumps are stopped (step 3.2.1) Core Spray System suction valves V-20-3 and V-20-32 are closed (step 3.2.2) Core Spray System 1 Parallel | |||
Standard: Places the Core Spray | |||
CUE: The breakers for valve V-20-3 and V-20-32 are in the OFF position. | CUE: The breakers for valve V-20-3 and V-20-32 are in the OFF position. | ||
Comment: | Comment: | ||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
9 Performance Step: 4 (step 3.2.4.2) | |||
Standard: Using MB-1 key, unlocks and opens the following CST valves: | |||
* V-20-1 (NW corner Room) | |||
* V-20-5 (NW corner Room) | |||
* V-20-34 (NW corner Room) | |||
Standard: Using MB-1 key, unlocks and opens the following CST valves: V-20-1 (NW corner Room) V-20-5 (NW corner Room) V-20-34 (NW corner Room) | |||
CUE: Valves V-20-1, V-20-5, and V-20-34 are unlocked and open. | CUE: Valves V-20-1, V-20-5, and V-20-34 are unlocked and open. | ||
NOTE: If the Candidate does not have the proper keys, ask where they can be obtained:the Controlled Key Locker in the Shift | NOTE: If the Candidate does not have the proper keys, ask where they can be obtained: | ||
Comment: | the Controlled Key Locker in the Shift Managers Office. (Not required to go get the key) | ||
Comment: | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
NRC Plant1 Page 4 of 8 | |||
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 5 (step 3.2.4.3) | |||
Standard: Calls the Control Room to start Core Spray System 1 main pump NZ01A or NZ01C. | |||
Appendix C Form ES-C- | CUE: Acknowledge the report. State that Core Spray Pump NZ01A has been started and is running. | ||
Standard: Calls the Control Room to start Core Spray System 1 main pump NZ01A or NZ01C.CUE: Acknowledge the report. | Comment: | ||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
9 Performance Step: 6 (step 3.2.6) | |||
Standard: Using the MB-1 key, unlocks and places the breaker for V-20-27 in the ON position (MCC 1A21B RB 23 E). | |||
Standard: Using the MB-1 key, unlocks and | |||
CUE: V-20-27 breaker is ON. | CUE: V-20-27 breaker is ON. | ||
Comment: | Comment: | ||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
9 Performance Step: 7 (step 3.2.7) | |||
Standard: On RB 51' NW, uses the PA-2235 key to open Torus Test Flow Return valve V-20-27 by placing upper keylock switch to the OPEN position (red light ON). | Standard: On RB 51' NW, uses the PA-2235 key to open Torus Test Flow Return valve V-20-27 by placing upper keylock switch to the OPEN position (red light ON). | ||
CUE: Valve V-20-27 indicates full open (red | CUE: Valve V-20-27 indicates full open (red light on). (See comment regarding KEYS in Step 4) | ||
Comment: | |||
NRC Plant1 Page 5 of 8 | |||
Comment: | |||
Appendix C Form ES-C-1 | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
Performance Information Performance Step: 8 Standard: Calls the Control Room to report that makeup to the Torus is in progress. | |||
CUE: (As Reactor Operator) repeat back the operators report. | |||
Comment: | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
Terminating Cue: Making-up to the Torus from the CST via Core Spray System 1 in accordance with Support Procedure 37. | |||
JPM Stop Time: _________________ | |||
NRC Plant1 Page 6 of 8 | |||
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Plant1 Examinees Name: __________________ | |||
Examiners Name: __________________ | |||
Date Performed: __________________ | Date Performed: __________________ | ||
Facility Evaluator: __________________ | Facility Evaluator: __________________ | ||
Number of Attempts: __________________ | |||
Time to Complete: __________________ | |||
Question: | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
===Response=== | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________ | |||
NRC Plant1 Page 7 of 8 | |||
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions: | |||
: 1. The Reactor is shutdown. | |||
: 2. Reactor water level is being maintained at 160 inches with feedwater. | |||
Appendix C Form ES-C- | |||
: 3. Drywell pressure is 1.1 psig and stable. | : 3. Drywell pressure is 1.1 psig and stable. | ||
: 4. Torus water level is 140 inches and lowering due to a leak. | : 4. Torus water level is 140 inches and lowering due to a leak. | ||
: 5. The Reactor Building is accessible. | : 5. The Reactor Building is accessible. | ||
: 6. Core Spray System 1 is operable and available. | : 6. Core Spray System 1 is operable and available. | ||
Task Cue: Line up and add makeup to the torus from the CST via Core Spray System 1 in accordance with Support Procedure 37. | Task Cue: | ||
Line up and add makeup to the torus from the CST via Core Spray System 1 in accordance with Support Procedure 37. | |||
THIS JPM IS SIMULATE ONLY. THERE WILL BE NO MANIPULATIONS OF PLANT COMPONENTS. | THIS JPM IS SIMULATE ONLY. THERE WILL BE NO MANIPULATIONS OF PLANT COMPONENTS. | ||
Appendix C Job Performance Measure Form ES-C- | NRC Plant1 Page 8 of 8 | ||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2630101003/2630104009 Task Title: Shift Battery Chargers Job Performance Measure No: NRC Plant2 (RO/SRO) | |||
K/A | K/A | ||
==Reference:== | ==Reference:== | ||
263000 K1.02 (RO 3.2/SRO 3.3)Examinee: | 263000 K1.02 (RO 3.2/SRO 3.3) | ||
Facility Evaluator: | Examinee: ___________________ NRC Examiner: ___________________ | ||
Method of Testing:Simulated Performance | Facility Evaluator: ___________________ Date: _________ | ||
: 4. Isolation Condenser valves V-14-33 and V-14-35 have been declared inoperable and the appropriate Tech Spec LCOs have been entered by the Control Room SRO.Task Standard: Static Charger C1 is removed from service and Static Charger C2 is in service.Required Materials: None | Method of Testing: | ||
Simulated Performance X Actual Performance _______________ | |||
Classroom _________ Simulator _________ Plant X Read to the Examinee: | |||
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied. | |||
Initial Conditions: | |||
: 1. Static Charger C1 is currently in service supplying DC-C. | |||
: 2. Electricians need to perform scheduled maintenance on Static Charger C1 while still energized from its AC source. | |||
: 3. Static Charger C2 has been verified to be in standby readiness. | |||
: 4. Isolation Condenser valves V-14-33 and V-14-35 have been declared inoperable and the appropriate Tech Spec LCOs have been entered by the Control Room SRO. | |||
Task Standard: Static Charger C1 is removed from service and Static Charger C2 is in service. | |||
Required Materials: None General | |||
==References:== | |||
Procedure 340.3, 125 Volt DC Distribution System C, Rev. 27 NRC Plant2 Page 1 of 9 | |||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Initiating Cue: Transfer operation from Static Charger C1 to Static Charger C2 IAW Procedure 340.3, 125 Volt DC Distribution System C, Section 6.0. | |||
Time Critical Task: No Validation Time: 16 minutes NRC Plant2 Page 2 of 9 | |||
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ___________ | |||
Standard: Provides repeat back of initiating cue. Evaluator acknowledges repeat back. | |||
Comment: | |||
Evaluator acknowledges repeat back. | ________________________________________________________________________ | ||
Comment: | ________________________________________________________________________ | ||
________________________________________________________________________ | |||
Performance Step: 2 Standard: Verifies Prerequisites and reviews Precautions and Limitations. | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
Performance Step: | |||
Comment:_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Plant2 Page 3 of 9 | |||
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 3 (step 6.3.3.1) | |||
Standard: Places the DC output breaker for Charger C1 (at charger cabinet) in the OFF position (Labeled DC POWER). | |||
CUE: The DC output breaker for Charger C1 is in the OFF position. | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
9 Performance Step: 4 (step 6.3.3.2) | |||
Standard: Places the breaker for Charger C1 on DC-C (in 4160V Room) in the OFF position. | |||
CUE: The breaker for Charger C1 on DC-C (in 4160V Room) in the OFF position (Labeled C1 STATIC CHARGER OUTPUT BREAKER). | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
9 Performance Step: 5 (step 6.3.4.1) | |||
Standard: Places the breaker for Charger C2 on DC-C (in 4160V Room) in the ON position (Labeled C1 STATIC CHARGER OUTPUT BREAKER). | |||
5 (step 6.3.4.1)Standard:Places the breaker for Charger C2 on DC-C (in 4160V Room) in the | |||
CUE: The breaker for Charger C2 on DC-C (in 4160V Room) is in the ON position. | CUE: The breaker for Charger C2 on DC-C (in 4160V Room) is in the ON position. | ||
Comment: | Comment: | ||
Appendix C Form ES-C- | NRC Plant2 Page 4 of 9 | ||
Appendix C Form ES-C-1 | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
NRC Plant2 Page 5 of 9 | |||
Appendix C Form ES-C-1 Performance Information Performance Step: 6 (step 6.3.4.2) | |||
Appendix C Form ES-C- | Standard: Checks Charger C2 voltage against Battery Bus voltage. | ||
6 (step 6.3.4.2)Standard:Checks Charger C2 | |||
CUE: Charger C2 output voltage is 2 volts LESS THAN Battery Bus voltage. | CUE: Charger C2 output voltage is 2 volts LESS THAN Battery Bus voltage. | ||
Standard: Adjusts the charger | Standard: Adjusts the charger output voltage (float) in the direction to raise charger voltage to match or be slightly above bus voltage. | ||
CUE: Charger voltage is now EQUAL TO bus voltage. | CUE: Charger voltage is now EQUAL TO bus voltage. | ||
Comment:_________________________________________________________________________________ | Comment: | ||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
9 Performance Step: 7 (step 6.3.4.3) | |||
Standard: Places the DC output breaker for Charger C2 (at charger cabinet) in the ON position. | |||
CUE: The DC output breaker for Charger C2 (at charger cabinet) in the ON position (Labeled DC POWER). | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Plant2 Page 6 of 9 | |||
Appendix C Form ES-C-1 Performance Information Performance Step: 8 (step 6.3.5) | |||
Standard: Checks Battery Bus voltage to maintain DC System voltage 130.2 - 135 volts. | |||
Comment:_________________________________________________________________________________ | CUE: DC Battery Bus voltage indicates 133 volts (no adjustments are required). | ||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: 9 (steps 6.3.6, 6.3.7, and 6.3.8) | |||
CUE: | Standard: Calls the Control Room to report Static Charger C2 is supplying DC-C. | ||
Comment: | Requests they declare V-14-33 and V-14-35 operable and exit the applicable Tech Specs. | ||
CUE: (As the Control Room) V-14-33 and V-14-35 have been declared operable; Tech Spec 3.7.D.1, 3.8.C and 3.8.E have been exited. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Terminating Cue: Static Charger C1 has been removed from service and Static Charger C2 has been placed into service. | |||
JPM Stop Time: ___________ | JPM Stop Time: ___________ | ||
NRC Plant2 Page 7 of 9 | |||
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Plant2 Examinees Name: __________________ | |||
Examiners Name: __________________ | |||
Date Performed: __________________ | Date Performed: __________________ | ||
Facility Evaluator: __________________ | Facility Evaluator: __________________ | ||
Number of Attempts: __________________ | |||
Time to Complete: __________________ | |||
Question: | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
===Response=== | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________ | |||
NRC Plant2 Page 8 of 9 | |||
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions: | |||
: 1. Static Charger C1 is currently in service supplying DC-C. | |||
: 2. Electricians need to perform scheduled maintenance on Static Charger C1 while still energized from its AC source. | |||
: 3. Static Charger C2 has been verified to be in standby readiness. | |||
: 4. Isolation Condenser valves V-14-33 and V-14-35 have been declared inoperable and the appropriate Tech Spec LCOs have been entered by the Control Room SRO. | |||
Task Cue: | |||
Transfer operation from Static Charger C1 to Static Charger C2 IAW Procedure 340.3, 125 Volt DC Distribution System C, Section 6.0. | |||
Appendix C Form ES-C- | |||
: 4. Isolation Condenser valves V-14-33 and V-14-35 have been declared inoperable and the appropriate Tech Spec LCOs have been entered by the Control Room SRO.Task Cue: Transfer operation from Static Charger C1 to Static Charger C2 IAW Procedure 340.3, 125 Volt DC Distribution | |||
THIS JPM IS SIMULATE ONLY. THERE WILL BE NO MANIPULATIONS OF PLANT COMPONENTS. | THIS JPM IS SIMULATE ONLY. THERE WILL BE NO MANIPULATIONS OF PLANT COMPONENTS. | ||
Appendix C Job Performance Measure Form ES-C- | NRC Plant2 Page 9 of 9 | ||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2860401402/2070501401/2070504401 Task Title: Lineup Fire Protection to the Isolation Condensers Job Performance Measure No: NRC Plant3 (RO/SRO) | |||
K/A | |||
==Reference:== | ==Reference:== | ||
286000 G2.4.35 (RO 3.3/SRO 3.5)Examinee: | 286000 G2.4.35 (RO 3.3/SRO 3.5) | ||
Facility Evaluator: | Examinee: ___________________ NRC Examiner: ___________________ | ||
Method of Testing:Simulated Performance | Facility Evaluator: ___________________ Date: _________ | ||
: 3. Condensate transfer pump | Method of Testing: | ||
: 4. Isolation Condenser | Simulated Performance X Actual Performance ________________ | ||
Task Standard: Fire Protection System lined up to Isolation Condenser | Classroom _________ Simulator _________ Plant X Read to the Examinee: | ||
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied. | |||
Initial Conditions: | |||
: 1. The Reactor is scrammed and isolated. | |||
: 2. Condensate transfer pump A is out of service. | |||
: 3. Condensate transfer pump B has failed. | |||
: 4. Isolation Condenser A has initiated from the standby readiness condition. | |||
: 5. The Fire Water System is operable and available. | |||
Task Standard: Fire Protection System lined up to Isolation Condenser A Required Materials: Fire Protection key (simulated) | |||
General | General | ||
==References:== | ==References:== | ||
Procedure 307, | Procedure 307, Isolation Condenser System, Rev. 92 Initiating Cue: Lineup the Fire Protection System to makeup to Isolation Condenser A in accordance with Procedure 307, Isolation Condenser System, Section 7.0. | ||
Notify the Control Room when the line-up is complete. | Notify the Control Room when the line-up is complete. | ||
NRC Plant3 Page 1 of 7 | |||
Note: Some simulated valve manipulations occur in a contaminated area. The Candidate is NOT to reach across | Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Time Critical Task: No Validation Time: 16 minutes Note: Some simulated valve manipulations occur in a contaminated area. The Candidate is NOT to reach across the contamination barrier. | ||
Appendix C Form ES-C- | NRC Plant3 Page 2 of 7 | ||
Standard: Provide repeat | |||
Evaluator acknowledges repeat back. | Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________ | ||
Comment: | Standard: Provide repeat back of initiating cue. Evaluator acknowledges repeat back. | ||
Comment: | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
Performance Step: 2 Standard: Verify Prerequisites and reviews Precautions and Limitations. | |||
CUE: All prerequisites have been met, Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
Performance Step: 2 Standard: Verify Prerequisites and | |||
CUE: All prerequisites have been met, Comment:_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Plant3 Page 3 of 7 | |||
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 3 (step 7.3.2.1) | |||
Standard: Closes Isolation Condenser Supply Isolation Valve V-11-41 on Reactor Building 23' elevation East. | |||
CUE: Valve V-11-41 is closed. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: | Performance Step: 4 (step 7.3.2.2) | ||
4 (step 7.3.2.2)Standard:Closes Makeup to Isolation Condenser Telltale Drain Valve V-11-63 on Reactor Building 23' elevation East. | Standard: Closes Makeup to Isolation Condenser Telltale Drain Valve V-11-63 on Reactor Building 23' elevation East. | ||
CUE: Valve V-11-63 is closed. | CUE: Valve V-11-63 is closed. | ||
Comment:_________________________________________________________________________________ | Comment: | ||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
9 Performance Step: 5 (step 7.3.2.3) | |||
Standard: Using the Fire Protection key, unlocks and opens Fire Protection to Isolation Condenser Cross-Tie Isolation Valve V-9-2099 on Reactor Building 23' elevation East. | |||
CUE: Valve V-9-2099 is unlocked and open. Note: If the Candidate does not have the key to unlock this valve, ask where the appropriate key can be obtained: the key can be obtained from the Controlled Key Locker in the Shift Managers Office (NOT required to go back for the key). | |||
NRC Plant3 Page 4 of 7 | |||
_________________________________________________________________________________ Performance Step: | Appendix C Form ES-C-1 Performance Information Comment: | ||
_________________________________________________________________________________ | |||
CUE: Valve V- | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
9 Performance Step: 6 (step 7.3.2.4) | |||
Standard: Opens Fire Protection to Isolation Condenser Makeup Valve V-11-49 on Reactor Building 23' elevation East. | |||
CUE: Valve V-11-49 is open. | |||
NOTE: This completes the in-plant lineup for CST to Isolation Condenser A. The Candidate should report in this step or next, that the in-plant lineup is complete. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: | Performance Step: 8 (step 7.3.2.5) | ||
8 (step 7.3.2.5) | Standard: Requests Control Room record initial isolation condenser shell level. | ||
Standard: Requests Control Room record | |||
CUE: Shell water level will be recorded. | CUE: Shell water level will be recorded. | ||
Comment:_________________________________________________________________________________ | Comment: | ||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Plant3 Page 5 of 7 | |||
Appendix C Form ES-C-1 Terminating Cue: Fire Protection System is lined up to Isolation Condenser A JPM Start Time: ____________ | |||
Validation of Completion Job Performance Measure No. NRC Plant3 Examinees Name: __________________ | |||
Examiners Name: __________________ | |||
Date Performed: __________________ | Date Performed: __________________ | ||
Facility Evaluator: __________________ | Facility Evaluator: __________________ | ||
Number of Attempts: __________________ | |||
Time to Complete: __________________ | |||
Question: | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
===Response=== | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________ | |||
NRC Plant3 Page 6 of 7 | |||
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions: | |||
: 1. The Reactor is scrammed and isolated. | |||
: 2. Condensate transfer pump A is out of service. | |||
: 3. Condensate transfer pump B has failed. | |||
: 4. Isolation Condenser A has initiated from the standby readiness condition. | |||
: 5. The Fire Water System is operable and available. | |||
Task Cue: | |||
Lineup the Fire Protection System to makeup to Isolation Condenser A in accordance with Procedure 307, Isolation Condenser System, Section 7.0. Notify the Control Room when the line-up is complete. | |||
Appendix C Form ES-C- | |||
: 3. Condensate transfer pump | |||
: 4. Isolation Condenser | |||
Task Cue: Lineup the Fire Protection System to makeup to Isolation Condenser | |||
THIS JPM IS SIMULATE ONLY. THERE WILL BE NO MANIPULATIONS OF PLANT COMPONENTS. | THIS JPM IS SIMULATE ONLY. THERE WILL BE NO MANIPULATIONS OF PLANT COMPONENTS. | ||
Appendix C Job Performance Measure Form ES-C- | NRC Plant3 Page 7 of 7 | ||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2020601002 Task Title: Respond to Power Oscillations (Recirc. Flow Oscillations) (Alternate Path) | |||
Job Performance Measure No: NRC Sim1 (RO/SRO) | Job Performance Measure No: NRC Sim1 (RO/SRO) | ||
K/A | K/A | ||
==Reference:== | ==Reference:== | ||
202002 A2.04 (RO 3.0/SRO 3.2)Examinee: | 202002 A2.04 (RO 3.0/SRO 3.2) | ||
Facility Evaluator: | Examinee: ___________________ NRC Examiner: ___________________ | ||
Method of Testing:Simulated Performance | Facility Evaluator: ___________________ Date: _________ | ||
Read to the Examinee:I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.Initial Conditions:1. The Reactor is at 90% power.Task Standard:The | Method of Testing: | ||
Required Materials: None | Simulated Performance Actual Performance X Classroom _________ Simulator X Plant _________ | ||
Read to the Examinee: | |||
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied. | |||
Initial Conditions: | |||
: 1. The Reactor is at 90% power. | |||
Task Standard: The A Recirculation Pump has been tripped. The A Recirculation Pump suction valve has been closed and Electricians have been notified to close the A Recirculation Pump discharge valve IAW ABN-2. | |||
Required Materials: None General | |||
==References:== | |||
ABN-2, Recirculation System Failures, Rev. 6 Initiating Cue: Power oscillations have been observed and attributed to fluctuations in reactor recirculation flow. Complete the applicable section of ABN-2, Recirculation System Failures. | |||
Time Critical Task: No Validation Time: 21 minutes NRC Sim1 Rev. 01 Page 1 of 9 | |||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Simulator Setup: | |||
: 1. IC65 | |||
: 2. Reduce power to approximately 90% with recirc. flow | : 2. Reduce power to approximately 90% with recirc. flow | ||
: 3. Fail Recirc. Pump A discharge valve OPEN: VLV-NSS006 to MECH SIEZE | : 3. Fail Recirc. Pump A discharge valve OPEN: VLV-NSS006 to MECH SIEZE | ||
: 4. Recirc. Pump A flow oscillations: MAL-RFC005A to 100% | : 4. Recirc. Pump A flow oscillations: MAL-RFC005A to 100% | ||
: 5. Place the recirc. controller in | : 5. Place the recirc. controller in V NRC Sim1 Rev. 01 Page 2 of 9 | ||
Standard: Provides repeat | |||
Evaluator acknowledges repeat back. | Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________ | ||
Comment: | Standard: Provides repeat back of initiating cue. Evaluator acknowledges repeat back. | ||
Comment: | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
Performance Step: 2 Standard: Recognizes flow/speed fluctuations on the A Recirculation Pump (Panel 3F). | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
Performance Step: 2 Standard: Recognizes flow/speed fluctuations on the | |||
Comment:_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Sim1 Rev. 01 Page 3 of 9 | |||
Appendix C Form ES-C-1 Performance Information Performance Step: 3 (step 3.3.2.A) | |||
Standard: At Panel 3F, depresses the AUTO/MAN pushbutton to transfer A Recirculation Pump speed control to MANUAL. | |||
NOTE: speed control is NOT regained. | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
9 Performance Step: 4 (step 3.3.2.D.1) | |||
Standard: Determines APRM oscillations are > 4.6% (Panel 4F) and generator load fluctuations are > 30 MWe (Panel 8F/9F). | |||
At Panel 3F, places the A Recirculation Pump Drive Motor Control switch to STOP. | |||
FLOOR CUE: APRM fluctuations are 5% peak to peak AND generator load fluctuations are 40 MWe peak to peak (if not physically present). | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: 5 (step 3.3.2.D.2) | |||
Standard: Refers to Step 3.1.2 of ABN-2 for a single recirculation pump trip when five loops were operating. | |||
Comment: | |||
NRC Sim1 Rev. 01 Page 4 of 9 | |||
Appendix C Form ES-C-1 | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
NRC Sim1 Rev. 01 Page 5 of 9 | |||
Appendix C Form ES-C-1 Performance Information Performance Step: 6 (step 3.1.2.A) | |||
Standard: At Panel 3F, confirms A Recirc. Pump discharge bypass valve is open (red light ON; green light OFF). | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
Performance Step: 7 (step 3.1.2.B) | |||
Standard: At Panel 3F, places A Recirculation Pump discharge valve control switch to CLOSE. Notifies SRO of valve failure. | |||
NOTE: The A Recirculation Pump discharge valve will not close. | |||
Comment: | Comment: | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
9 Performance Step: 8 (step 3.1.2.D.1) | |||
Standard: At Panel 3F, places A Recirculation Pump suction valve control switch to CLOSE (red light OFF; green light ON). | |||
Comment: | Comment: | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Sim1 Rev. 01 Page 6 of 9 | |||
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 9 (step 3.1.2.D.2) | |||
Standard: Refers to Attachment ABN-2-1; directs electrician to MCC 1A21A to close Recirc. Pump A discharge valve NG03A. | |||
Comment: | Comment: | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Terminating Cue: The A Recirculation Pump has been tripped. The A Recirculation Pump suction valve has been closed and Electricians have been notified to close the A Recirculation Pump discharge valve IAW ABN-2. | |||
JPM Stop Time: ____________ | JPM Stop Time: ____________ | ||
NRC Sim1 Rev. 01 Page 7 of 9 | |||
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Sim1 Examinees Name: __________________ | |||
Examiners Name: __________________ | |||
Date Performed: __________________ | Date Performed: __________________ | ||
Facility Evaluator: __________________ | |||
Number of Attempts: __________________ | |||
Time to Complete: __________________ | |||
Question: | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
===Response=== | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________ | |||
NRC Sim1 Rev. 01 Page 8 of 9 | |||
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions: | |||
: 1. The Reactor is at 90% power. | |||
Task Cue: | |||
Power oscillations have been observed and attributed to fluctuations in reactor recirculation flow. Complete the applicable section of ABN-2, Recirculation System Failures. | |||
NRC Sim1 Rev. 01 Page 9 of 9 | |||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2040101412 Task Title: Place a Second RWCU Pump in Service Job Performance Measure No: NRC Sim2 (RO/SRO) | |||
Appendix C Job Performance Measure Form ES-C- | |||
K/A | K/A | ||
==Reference:== | ==Reference:== | ||
204000 A4.01 (RO 3.1/SRO 3.0)Examinee: | 204000 A4.01 (RO 3.1/SRO 3.0) | ||
Facility Evaluator: | Examinee: ___________________ NRC Examiner: ___________________ | ||
Method of Testing:Simulated Performance | Facility Evaluator: ___________________ Date: _________ | ||
Read to the Examinee:I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.Initial Conditions:1. The Reactor is at 95% power.2. Reactor water level, power, and pressure are constant. | Method of Testing: | ||
: 3. Reactor Water Cleanup Recirculation Pump | Simulated Performance Actual Performance X Classroom _________ Simulator X Plant _________ | ||
: 6. An Equipment Operator is in the field and has been | Read to the Examinee: | ||
Required Materials: None Appendix C Job Performance Measure Form ES-C- | I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied. | ||
Initial Conditions: | |||
: 1. The Reactor is at 95% power. | |||
: 2. Reactor water level, power, and pressure are constant. | |||
: 3. Reactor Water Cleanup Recirculation Pump A is in service with filter ND05A. | |||
: 4. Chemistry samples show sulfates are out-of-spec high requiring two RWCU pump operation. | |||
: 5. RBCCW is valved-in to the B Cleanup Recirculation Pump. | |||
: 6. An Equipment Operator is in the field and has been briefed on the evolution and has a copy of the procedure. | |||
Task Standard: The second Cleanup Recirculation Pump is in service with system flow approximately 700 gpm. | |||
Required Materials: None NRC Sim2 Page 1 of 10 | |||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET General | |||
==References:== | ==References:== | ||
Procedure 303, | Procedure 303, Reactor Cleanup Demineralizer System, Rev. 95 Initiating Cue: Place a second reactor water cleanup pump in service IAW Procedure 303, Section 22.0, and establish approximately 700 GPM system flow. | ||
Step 22.3.1 has already been | Step 22.3.1 has already been performed. When the second Cleanup Recirculation Pump is in service, another Operator will complete steps 22.3.14 through 22.3.17. | ||
Time Critical Task: No Validation Time: 27 minutes | Time Critical Task: No Validation Time: 27 minutes Simulator Setup: | ||
: 1. IC-65, with power reduced to 95% power, with recirculation flow. | |||
: 2. Cleanup Pump A is in service. | |||
: 3. LOA-RCU022 (for valve V-16-36 Pump A min. flow) and LOA-RCU023 (for valve V-16-37 Pump B moin. flow valve) to 1 to open the cleanup pumps min. flow valves. | |||
: 4. LOA-RCU022 and LOA-RCU023 to 0 to close the cleanup pumps min. flow valves. | |||
: 5. Adjust (raise) RBCCW to the NHRX HX (on drawing RBC02, change RBCCW flow through the NRHX to about 0.6 valve opening, when given the BOOTH CUE) | |||
NRC Sim2 Page 2 of 10 | |||
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________ | |||
Standard: Provides repeat back of initiating cue. Evaluator acknowledges repeat back. | |||
Comment: | |||
________________________________________________________________________ | |||
Appendix C Form ES-C- | ________________________________________________________________________ | ||
Standard: Provides repeat | ________________________________________________________________________ | ||
Evaluator acknowledges repeat back. | Performance Step: 2 Standard: Verifies Prerequisites; Review Precautions and Limitations. | ||
Comment: | Comment: | ||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
Performance Step: 3 (step 22.3.2) | |||
Standard: Places placards on Panel 3F for heat balance adjustment and on Letdown Flow Controller to not exceed 760 GPM flow. | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
Performance Step: | |||
Comment:_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Sim2 Page 3 of 10 | |||
Appendix C Form ES-C-1 NRC Sim2 Page 4 of 10 | |||
Appendix C Form ES-C-1 Performance Information Performance Step: 4 (step 22.3.3) | |||
Standard: Confirms B cleanup pump discharge valve (V-16-50) is closed (red light OFF; green light ON). | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: | 9 Performance Step: 5 (step 22.3.4) | ||
Comment: | Standard: Directs equipment operator to open minimum flow valves V-16-36 & V-16-37 (using the local toggle switches). | ||
NOTE: Activate LOA-RCU022 and LOA-RCU023 to 1 (OPEN). (Monitor and adjust RBCCW flow to CU system as required on screen RBC02 to about 0.6 RBCCW flow through the NRHX.) | |||
BOOTH CUE: As the EO, report that both minimum flow valves V-16-36 and V-16-37 are open. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Sim2 Page 5 of 10 | |||
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 6 (step 22.3.5) | |||
Standard: Makes plant announcement for the pump start (not required for critical task). | |||
At Panel 3F, places the B Cleanup Recirculation Pump control switch to START (red light ON; green light OFF) | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
9 Performance Step: 7 (22.3.6) | |||
Standard: Slowly opens B Cleanup Recirculation Pump discharge valve V-16-50 until a small increase in pump discharge pressure is noted on Panel 3F. To throttle this valve, place the valve to OPEN, then to the neutral position to hold the valve in place. | |||
Comment: | Comment: | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: 8 (step 22.3.7) | Performance Step: 8 (step 22.3.7) | ||
Standard: Slowly opens FCV-ND-16 to | Standard: Slowly opens FCV-ND-16 to maintain original pump discharge pressure. | ||
Comment:_________________________________________________________________________________ | Comment: | ||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
NRC Sim2 Page 6 of 10 | |||
Appendix C Form ES-C-1 Performance Information Performance Step: 9 (step 22.3.8) | |||
Standard: Adjusts PCV-ND11 to maintain system pressure at approximately 90 psig. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
Performance Step: 10 (step 22.3.9/22.3.10) | |||
Standard: Directs Equipment Operator to monitor: | |||
* Demineralizer strainer dP | |||
* Demineralizer dP | |||
* Filter dP FLOOR CUE: As the Field Equipment Operator, Report: | |||
* Demineralizer strainer dP is 7 psid | |||
* Demineralizer dP is 8 psid | |||
* Filter dP is 18 psid Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
9 Performance Step: 11 (step 22.3.11) | |||
Standard: Continues to open the pump discharge valve while adjusting pressure and flow, until the discharge valve is full open (red light ON; green light OFF). | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
NRC Sim2 Page 7 of 10 | |||
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 12 (step 22.3.12) | |||
Standard: Increases flow with FCV ND-16 until flow is approximately 700 gpm, but does not exceed 760 gpm. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
9 Performance Step: 13 (step 22.3.13) | |||
Standard: When flow exceeds 500 gpm, directs Equipment Operator to close minimum flow valves V-16-36 & V-16-37 using the local toggle switches. | |||
NOTE: Activate LOA-RCU022 and LOA-RCU023 to 0 (CLOSED). (Monitor and adjust RBCCW flow to CU system as required.) | |||
BOOTH CUE: As the EO, report that both minimum flow valves V-16-36 and V-16-37 are closed. | |||
FLOOR CUE: The candidate may request non-regeneration temperature: Report 95° F. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Terminating Cue: The second Cleanup Recirculation Pump is in service with system flow approximately 700 gpm. | |||
JPM Stop Time: ____________ | JPM Stop Time: ____________ | ||
NRC Sim2 Page 8 of 10 | |||
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Sim2 Examinees Name: __________________ | |||
Examiners Name: __________________ | |||
Date Performed: __________________ | Date Performed: __________________ | ||
Facility Evaluator: __________________ | |||
Number of Attempts: __________________ | |||
Time to Complete: __________________ | |||
Question: | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
===Response=== | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________ | |||
NRC Sim2 Page 9 of 10 | |||
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions: | |||
: 1. The Reactor is at 95% power. | |||
: 2. Reactor water level, power, and pressure are constant. | |||
: 3. Reactor Water Cleanup Recirculation Pump A is in service with filter ND05A. | |||
: 4. Chemistry samples show sulfates are out-of-spec high requiring two RWCU pump operation. | |||
: 5. RBCCW is valved-in to the B Cleanup Recirculation Pump. | |||
: 6. An Equipment Operator is in the field and has been briefed on the evolution and has a copy of the procedure. | |||
Task Cue: | |||
Place a second reactor water cleanup pump in service IAW Procedure 303, Section 22.0, and establish approximately 700 GPM system flow. Step 22.3.1 has already been performed. When the second Cleanup Recirculation Pump is in service, another Operator will complete steps 22.3.14 through 22.3.17. | |||
NRC Sim2 Page 10 of 10 | |||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2090101005 Task Title: Shutdown Core Spray After Inadvertent Initiation (Alternate Path) | |||
Appendix C Job Performance Measure Form ES-C- | |||
Job Performance Measure No: NRC Sim3 (RO/SRO) | Job Performance Measure No: NRC Sim3 (RO/SRO) | ||
K/A | K/A | ||
==Reference:== | ==Reference:== | ||
209001 A4.01 (RO 3.8/SRO 3.6)Examinee: | 209001 A4.01 (RO 3.8/SRO 3.6) | ||
Facility Evaluator: | Examinee: ___________________ NRC Examiner: ___________________ | ||
Method of Testing:Simulated Performance | Facility Evaluator: ___________________ Date: _________ | ||
Read to the Examinee:I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.Initial Conditions:1. The Reactor is at 100% power.2. Reactor water level, power, and pressure are in the normal bands and are constant.3. Low-Low Reactor Water Level | Method of Testing: | ||
: 5. All other systems are operating properly.6. The US has determined that adequate core cooling is assured. | Simulated Performance Actual Performance X Classroom _________ Simulator X Plant _________ | ||
Task Standard: Core Spray System I has been shutdown following | Read to the Examinee: | ||
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied. | |||
Initial Conditions: | |||
: 1. The Reactor is at 100% power. | |||
: 2. Reactor water level, power, and pressure are in the normal bands and are constant. | |||
: 3. Low-Low Reactor Water Level Instrument RE02A has failed downscale. | |||
: 4. Core Spray Systems 1 and 2 have initiated. | |||
: 5. All other systems are operating properly. | |||
: 6. The US has determined that adequate core cooling is assured. | |||
Task Standard: Core Spray System I has been shutdown following automatic initiation. | |||
Required Materials: None General | Required Materials: None General | ||
==References:== | ==References:== | ||
Procedure 308, Emergency Core Cooling System Operation, Rev. | Procedure 308, Emergency Core Cooling System Operation, Rev. | ||
76 Appendix C Job Performance Measure Form ES-C- | 76 NRC Sim3 Page 1 of 8 | ||
Time Critical Task: | |||
3.Fail control switch for Core Spray Booster Pump NZ03A in START (BKR-CSS001 to MECH SIEZE AFTER the core spray system is running)4.To trip the Core Spray Booster Bump NZ03A breaker locally: BKR-CSS001 to TRIP Appendix C Form ES-C- | Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Initiating Cue: Secure Core Spray System 1 IAW Procedure 308, Section 5.0. Another Operator will secure Core Spray System 2. | ||
Standard: Provides repeat | Time Critical Task: No Validation Time: 20 minutes Simulator Setup: | ||
Evaluator acknowledges repeat back. | : 1. IC-65 | ||
Comment: | : 2. Fail RPV water level transmitter RE02A low (MAL-NSS007H to 85) | ||
: 3. Fail control switch for Core Spray Booster Pump NZ03A in START (BKR-CSS001 to MECH SIEZE AFTER the core spray system is running) | |||
: 4. To trip the Core Spray Booster Bump NZ03A breaker locally: BKR-CSS001 to TRIP NRC Sim3 Page 2 of 8 | |||
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________ | |||
Standard: Provides repeat back of initiating cue. Evaluator acknowledges repeat back. | |||
Comment: | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
Performance Step: 2 Standard: Verify Prerequisites; | ________________________________________________________________________ | ||
Comment:_________________________________________________________________________________ | Performance Step: 2 Standard: Verify Prerequisites; Review Precautions and Limitations. | ||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Sim3 Page 3 of 8 | |||
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 4 (step 5.3.2.1) | |||
Standard: Overrides start logic for Core Spray Systems 1 and 2 by depressing RE02A OVERRIDE pushbutton located on the logic mimic on Panel 1F/2F. Observes amber OVERRIDE light is lit and the CH A ACTUATED light extinguishes. | |||
Resets Core Spray start logic by depressing all ACTUATED pushbuttons located on the logic mimic on Panel 1F/2F. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: 5 (step 5.3.3) | Performance Step: 5 (step 5.3.3) | ||
Standard: At Panel 1F/2F, confirms Core | Standard: At Panel 1F/2F, confirms Core Spray System I Parallel Isolation Valves V-20-15 and V-20-40 are closed by observing green CLOSED indicating lights illuminated and red OPEN indicating lights extinguished. | ||
Comment: | Comment: | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Sim3 Page 4 of 8 | |||
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 6 (step 5.3.4) | |||
NOTE: Core Spray System 1 Booster Pump NZ03A does not trip remotely. | |||
Standard: At Panel 1F/2F, secures Core Spray System 1 Booster Pump NZ03A by placing its control switch to the STOP position. Observes the pump remains running based on no change in pump indications (red light ON; green light OFF; and discharge pressure unchanged) | |||
Directs the Equipment Operator to trip Core Spray Booster Pump NZ03A by opening its breaker at USS 1A2 located in the 480V Room. | |||
BOOTH CUE: As EO, acknowledge order to trip Core Spray Booster Pump NZ03A. | |||
Input BKR-CSS001 to TRIP, and then report the breaker is tripped for Core Spray Booster Pump NZ03A. | |||
Standard: Determines pump is tripped by observing pump status lights (red light OFF, green light ON) and pump discharge pressure and amps decrease. | |||
Comment: | Comment: | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
9 Performance Step: 7 (step 5.3.5) | |||
Standard: At Panel 1F/2F, secures Core Spray System 1 Main Pump NZ01A by placing its control switch to the STOP position. (red light OFF; green light ON; lowering pump discharge pressure and amps). | |||
Comment: | |||
NRC Sim3 Page 5 of 8 | |||
Appendix C Form ES-C-1 | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Information Performance Step: | Performance Information Performance Step: 8 (step 5.3.6/5.3.7) | ||
8 (step 5.3.6/5.3.7)Standard:Confirms the | Standard: Confirms the System is filled and vented. | ||
Verify Core Spray System 1 is in Standby Readiness. | Verify Core Spray System 1 is in Standby Readiness. | ||
FLOOR CUE:Another Operator will verify the Core Spray System I is filled and vented, and that the Core Spray System I is in Standby Readiness. | FLOOR CUE: Another Operator will verify the Core Spray System I is filled and vented, and that the Core Spray System I is in Standby Readiness. | ||
Comment:_________________________________________________________________________________ | Comment: | ||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Terminating Cue: Core Spray System I has been shutdown following automatic initiation. | Terminating Cue: Core Spray System I has been shutdown following automatic initiation. | ||
JPM Stop Time: ____________ | JPM Stop Time: ____________ | ||
NRC Sim3 Page 6 of 8 | |||
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Sim3 Examinees Name: __________________ | |||
Examiners Name: __________________ | |||
Date Performed: __________________ | Date Performed: __________________ | ||
Facility Evaluator: __________________ | |||
Number of Attempts: __________________ | |||
Time to Complete: __________________ | |||
Question: | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
===Response=== | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________ | |||
NRC Sim3 Page 7 of 8 | |||
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions: | |||
: 1. The Reactor is at 100% power. | |||
: 2. Reactor water level, power, and pressure are in the normal bands and are constant. | |||
: 3. Low-Low Reactor Water Level Instrument RE02A has failed downscale. | |||
: 4. Core Spray Systems 1 and 2 have initiated. | |||
: 5. All other systems are operating properly. | |||
: 6. The US has determined that adequate core cooling is assured. | |||
Task Cue: | |||
Secure Core Spray System 1 IAW Procedure 308, Section 5.0. Another Operator will secure Core Spray System 2. | |||
NRC Sim3 Page 8 of 8 | |||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2120501402 Task Title: Bypass RPS Scram Logic Trips Job Performance Measure No: NRC Sim4 (RO/SRO) | |||
Appendix C Job Performance Measure Form ES-C- | |||
K/A | K/A | ||
==Reference:== | ==Reference:== | ||
295037 EA1.01 (RO 4.6/SRO 4.6)Examinee: | 295037 EA1.01 (RO 4.6/SRO 4.6) | ||
Facility Evaluator: | Examinee: ___________________ NRC Examiner: ___________________ | ||
Method of Testing:Simulated Performance | Facility Evaluator: ___________________ Date: _________ | ||
Read to the Examinee:I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.Initial Conditions:1. The reactor was manually scrammed while at power.2. A partial failure to scram has occurred.Task Standard:The RPS trips have been | Method of Testing: | ||
Required Materials: 4 EOP Bypass Plugs | Simulated Performance Actual Performance X Classroom _________ Simulator X Plant _________ | ||
Read to the Examinee: | |||
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied. | |||
Initial Conditions: | |||
: 1. The reactor was manually scrammed while at power. | |||
: 2. A partial failure to scram has occurred. | |||
Task Standard: The RPS trips have been bypassed, a manual scram inserted, and all control rods are fully inserted. | |||
Required Materials: 4 EOP Bypass Plugs General | |||
==References:== | |||
: 1. EMG-3200-01B, RPV Control - With ATWS. Rev. 14 | |||
: 2. Support Procedure 21, Alternate Insertion of Control Rods, Rev. 14 Initiating Cue: Reset the scram and manually scram the reactor, IAW Support Procedure 21. | |||
Time Critical Task: No NRC Sim4 Page 1 of 9 | |||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Validation Time: 15 minutes Simulator Setup: | |||
: 1. IC-65 | |||
: 2. Insert hydraulic lock on control rods (partial): MAL-CRD021A at 100% | |||
: 3. Manually scram the reactor | |||
: 4. Manually initiate ARI | |||
: 4. Following the scram, place Mode switch in Shutdown | |||
: 4. After RPV water level recovers, trip 2 FW pumps NRC Sim4 Page 2 of 9 | |||
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________ | |||
Standard: Provide repeat back of initiating cue. Evaluator acknowledges repeat back. | |||
1 | Comment: | ||
________________________________________________________________________ | |||
Evaluator acknowledges repeat back. | ________________________________________________________________________ | ||
Comment: | ________________________________________________________________________ | ||
Performance Step: 2 (step 3.2 of Support Procedure 21) | |||
Standard: Identifies a hydraulic ATWS (Group scram solenoids are DE-ENERGIZED; individual scram lights for each control rod is ON) | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
Performance Step: 3 (step 5.1.1) | |||
Standard: At Panel 4F, starts the standby CRD pump by placing its control switch to START (red light ON; green light OFF). | |||
Performance Step: 2 | Comment: | ||
Comment:_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Sim4 Page 3 of 9 | |||
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 4 (step 5.1.2) | |||
Standard: Bypasses ARI by placing the ARI Normal/Bypass Switch in the BYPASS position in the rear of Panel 8R. | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
9 Performance Step: 5 (step 5.1.3) | |||
Standard: Resets ARI by depressing the ARI Manual reset pushbutton on Panel 4F. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
9 Performance Step: 6 (step 5.1.4) | |||
Standard: 1) Obtains four (4) bypass plugs from the EOP toolbox. | |||
: 2) Opens EOP BYPASS PLUGS panel in the rear of Panel 6R. | |||
* Inserts a bypass plug in position BP5. | |||
* Inserts a bypass plug in position BP6. | |||
: 3) Opens EOP BYPASS PLUGS panel in the rear of Panel 7R. | |||
* Inserts a bypass plug in position BP5. | |||
* Inserts a bypass plug in position BP6. | |||
Comment: | |||
NRC Sim4 Page 4 of 9 | |||
Appendix C Form ES-C-1 | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Sim4 Page 5 of 9 | |||
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 7 (step 5.1.5) | |||
Standard: At Panel 4F, places the SDV HI LVL BYPASS switch to the BYPASS position. | |||
Comment: | Comment: | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
9 Performance Step: 8 (step 5.1.6) | |||
Comment:_________________________________________________________________________________ | Standard: Resets the scram by depressing the Scram Reset pushbutton on Panel 4F. | ||
SIM BOOTH NOTE: Delete the hydraulic fail-to-scram after the scram is reset. | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: 9 (step 5.1.7) | |||
Standard: At Panel 4F, confirms the SDV vent and drain valves indicate open. | |||
Comment: | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Sim4 Page 6 of 9 | |||
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 10 Standard: When the SDV LEVEL HI-HI alarms clear (H-1-b/H-2-b), depresses both manual scram pushbuttons at Panel 4F. Verifies all control rods inserted and notifies SRO of all control rods inserted (not required for critical task). | |||
NOTE: All control rods will insert. | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Terminating Cue: The RPS trips have been bypassed, a manual scram inserted, and all control rods are fully inserted. | |||
JPM Stop Time: ____________ | JPM Stop Time: ____________ | ||
NRC Sim4 Page 7 of 9 | |||
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Sim4 Examinees Name: __________________ | |||
Examiners Name: __________________ | |||
Date Performed: __________________ | Date Performed: __________________ | ||
Facility Evaluator: __________________ | |||
Number of Attempts: __________________ | |||
Time to Complete: __________________ | |||
Question: | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
===Response=== | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________ | |||
NRC Sim4 Page 8 of 9 | |||
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions: | |||
: 1. The reactor was manually scrammed while at power. | |||
: 2. A partial failure to scram has occurred. | |||
Task Cue: | |||
Reset the scram and manually scram the reactor, IAW Support Procedure 21. | |||
NRC Sim4 Page 9 of 9 | |||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2000501435 Task Title: Prepare the Torus for Venting for Pressure Control Job Performance Measure No: NRC Sim5 (RO/SRO) | |||
Appendix C Job Performance Measure Form ES-C- | |||
K/A | K/A | ||
==Reference:== | ==Reference:== | ||
295024 EA1.19 (RO 3.3/SRO 3.4)Examinee: | 295024 EA1.19 (RO 3.3/SRO 3.4) | ||
Facility Evaluator: | Examinee: ___________________ NRC Examiner: ___________________ | ||
Method of Testing:Simulated Performance | Facility Evaluator: ___________________ Date: _________ | ||
Read to the Examinee:I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.Initial Conditions:1. The reactor scrammed due to a LOCA.2. The mode switch is in SHUTDOWN. | Method of Testing: | ||
: 3. For the purpose of this JPM, Drywell pressure is 28 psig.4. Torus venting has been directed by the EOPs.Task Standard:Preparations for venting the Torus are complete IAW Section 2.0 of Support Procedure 32. | Simulated Performance Actual Performance X Classroom _________ Simulator X Plant _________ | ||
Required Materials: 1 EOP Bypass Plug | Read to the Examinee: | ||
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied. | |||
Initial Conditions: | |||
: 1. The reactor scrammed due to a LOCA. | |||
: 2. The mode switch is in SHUTDOWN. | |||
: 3. For the purpose of this JPM, Drywell pressure is 28 psig. | |||
: 4. Torus venting has been directed by the EOPs. | |||
Task Standard: Preparations for venting the Torus are complete IAW Section 2.0 of Support Procedure 32. | |||
Required Materials: 1 EOP Bypass Plug General | |||
==References:== | |||
: 1. EMG-3200-02, Primary Containment Control, Rev. 17 | |||
: 2. Support Procedure 32, Venting the Torus for Primary Containment High Pressure, Rev. 17 NRC Sim5 Rev. 01 Page 1 of 10 | |||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Initiating Cue: Prepare the torus for venting due to high Primary Containment pressure IAW Support Procedure 32, Section 2.0. | |||
Time Critical Task: No Validation Time: 20 minutes Simulator Setup: | |||
: 1. IC-65 2 Even though DW pressure of 28 psig will be simulated in this JPM, it is still necessary to have DW pressure above 3 psig to auto start SGTS (MAL-NSS005D to 1%) | |||
: 3. Place Mode switch in Shutdown NRC Sim5 Rev. 01 Page 2 of 10 | |||
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________ | |||
Standard: Provide repeat back of initiating cue. Evaluator acknowledges repeat back. | |||
Comment: | |||
Standard: Provide repeat | ________________________________________________________________________ | ||
Evaluator acknowledges repeat back. | ________________________________________________________________________ | ||
Comment: | ________________________________________________________________________ | ||
Performance Step: 2 (step 2.1) | Performance Step: 2 (step 2.1) | ||
Standard: At Panel 1F/2F, verifies | Standard: At Panel 1F/2F, verifies Torus water level is below 348 inches. | ||
Comment:_________________________________________________________________________________ | Comment: | ||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Sim5 Rev. 01 Page 3 of 10 | |||
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 3 (step 2.2) | |||
Standard: Evacuates the Reactor Building by performing the following: | |||
* Sounds the Reactor Building Evacuation Alarm by placing the switch to REACTOR BLDG EVAC. | |||
* Announces: "Primary containment venting will commence in approximately 5 minutes. All personnel evacuate the Reactor Building immediately. Stand clear of the stack and the Reactor Building fan pad" on the PAGING phone. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
9 Performance Step: 4 (step 2.3) | |||
Standard: Selects a SGTS train at Panel 11R and places its control switch in the HAND position (exhaust fan starts: red light ON, green light OFF; fan inlet and outlet valves open: red light ON, green light OFF; orifice valve closes: green light ON, red light OFF) | |||
NOTE: One SGTS train should already be running. The candidate may select the SGTS train that is already running, but still must place the control switch for that train in HAND. | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
NRC Sim5 Rev. 01 Page 4 of 10 | |||
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 5 (step 2.4) | |||
Comment:_________________________________________________________________________________ | Standard: Closes SGTS Crosstie at Panel 11R placing the SGTS crosstie valve V-28-48 in the CLOSED position (green light ON; red light OFF). | ||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: 6 (step 2.5) | |||
Standard: Confirms RB Supply Fans secured at Panel 11R (RB Supply Fans Off: green light ON, red light OFF) | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
Performance Step: 7 (step 2.6) | |||
Standard: Confirm RB Exhaust Fans secured at Panel 11R (RB Exhaust Fans Off: green light ON, red light OFF) | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
NRC Sim5 Rev. 01 Page 5 of 10 | |||
Appendix C Form ES-C-1 Performance Information Performance Step: 8 (step 2.7) | |||
Standard: At Panel 4F, verifies the Mode Switch is NOT in RUN. | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
9 Performance Step: 9 (step 2.8) | |||
Standard: Obtains one (1) bypass plug from the EOP toolbox in the Control Room. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
9 Performance Step: 10 (step 2.9.1) | |||
Standard: Opens EOP BYPASS PLUGS panel at the rear of Panel 10XF, and inserts bypass plug into position BP5. | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
NRC Sim5 Rev. 01 Page 6 of 10 | |||
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 11 (step 2.10) | |||
Standard: Opens EOP BYPASS PLUGS panel at the rear of Panel 11R, removes bypass plug from position BP4 and inserts bypass plug into position BP1. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
9 Performance Step: 12 (step 2.11) | |||
Standard: At Panel | Standard: At Panel 11F, places the TORUS/ DRYWELL ISOLATION VALVE BYPASS PERMISSIVE keylock switch in the TORUS position. | ||
Comment: | NOTE: This switch is not labeled, but does have the following annotation above the keylock switch: Ensure Air Sample Taken Before Purging Drywell or Torus. | ||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
9 Performance Step: 13 (step 2.12) | |||
Standard: At Panel 11F, places the TORUS/DW VENT AND PURGE ISOL VLVS HI RAD BYP keylock switches for Channels 1 and 2 in the BYPASS position. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Sim5 Rev. 01 Page 7 of 10 | |||
Appendix C Form ES-C-1 Performance Information Performance Step: 14 (step 2.13) | |||
Standard: Reports to the SRO that the Torus venting preparations are complete. | |||
Comment: | FLOOR CUE: Acknowledge the report. | ||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Terminating Cue: Preparations for venting the Torus are complete IAW Section 2.0 of Support Procedure 32. | |||
JPM Stop Time: ____________ | JPM Stop Time: ____________ | ||
NRC Sim5 Rev. 01 Page 8 of 10 | |||
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Sim5 Examinees Name: __________________ | |||
Examiners Name: __________________ | |||
Date Performed: __________________ | Date Performed: __________________ | ||
Facility Evaluator: __________________ | |||
Number of Attempts: __________________ | |||
Time to Complete: __________________ | |||
Question: | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
===Response=== | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________ | |||
NRC Sim5 Rev. 01 Page 9 of 10 | |||
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions: | |||
: 1. The reactor scrammed due to a LOCA. | |||
: 2. The mode switch is in SHUTDOWN. | |||
: 3. For the purposes of this JPM, Drywell pressure is 28 psig. | |||
: 4. Torus venting has been directed by the EOPs. | |||
Task Cue: | |||
Prepare the torus for venting due to high Primary Containment pressure IAW Support Procedure 32, Section 2.0. | |||
NRC Sim5 Rev. 01 Page 10 of 10 | |||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2640201003 Task Title: Perform the Emergency Diesel Generator Load Test (Alternate Path) | |||
Appendix C Job Performance Measure Form ES-C- | |||
Job Performance Measure No: NRC Sim6 (RO/SRO) | Job Performance Measure No: NRC Sim6 (RO/SRO) | ||
K/A | K/A | ||
==Reference:== | ==Reference:== | ||
264000 A4.04 (RO 3.7/SRO 3.7)Examinee: | 264000 A4.04 (RO 3.7/SRO 3.7) | ||
Facility Evaluator: | Examinee: ___________________ NRC Examiner: ___________________ | ||
Method of Testing:Simulated Performance | Facility Evaluator: ___________________ Date: _________ | ||
Read to the Examinee:I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.Initial Conditions:1. The Reactor is at 100% power, with all systems normally aligned.2. All items listed in | Method of Testing: | ||
Required Materials: Prepared copy of | Simulated Performance Actual Performance X Classroom _________ Simulator X Plant _________ | ||
Read to the Examinee: | |||
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied. | |||
Initial Conditions: | |||
: 1. The Reactor is at 100% power, with all systems normally aligned. | |||
: 2. All items listed in Prerequisite Section 3.0 of Procedure 636.4.003, Diesel Generator #1 Load Test, have been verified. | |||
: 3. Steps 6.1 through 6.5 of Procedure 636.4.003 have been completed. | |||
: 4. The System Dispatcher has been contacted and grid conditions are stable. | |||
: 5. An EO has been briefed, has a copy of the procedure and is stationed at EDG #1 with a radio. | |||
Task Standard: Following startup/loading of EDG1 for surveillance, EDG1 has been shutdown by the Candidate. | |||
Required Materials: Prepared copy of procedure 636.4.003 (up through step 6.5). | |||
General | General | ||
==References:== | ==References:== | ||
1.Procedure 636.4.003, Diesel | : 1. Procedure 636.4.003, Diesel Generator #1 Load test, Rev. 74 NRC Sim6 Page 1 of 10 | ||
Time Critical Task: No Validation Time: 22 minutes Simulator Setup:1.IC-65 2.Annunciator T3b, EDG1 ENG TEMP HI: | |||
Standard: Provide repeat | Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Initiating Cue: Beginning with step 6.6, perform Diesel Generator #1 Load Test IAW Procedure 636.4.003 for scheduled surveillance. | ||
Evaluator acknowledges repeat back. | Time Critical Task: No Validation Time: 22 minutes Simulator Setup: | ||
Comment: | : 1. IC-65 | ||
: 2. Annunciator T3b, EDG1 ENG TEMP HI: ANN-T-6b to ON during the EDG run (step 12) | |||
: 3. Setup EDG on the PPC NRC Sim6 Page 2 of 10 | |||
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________ | |||
Standard: Provide repeat back of initiating cue. Evaluator acknowledges repeat back. | |||
Comment: | |||
________________________________________________________________________ | |||
________________________________________________________________________ | |||
Performance Step: | ________________________________________________________________________ | ||
NOTE/FLOOR CUE:All prerequisites have been | Performance Step: 2 Standard: Verifies Prerequisites, review Precautions and Limitations. | ||
Comment: | NOTE/FLOOR CUE: All prerequisites have been verified, as outlined in the Initial Conditions. | ||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Sim6 Page 3 of 10 | |||
Appendix C Form ES-C-1 Performance Information Performance Step: 3 (step 6.6) | |||
Standard: Confirms EDG lineup: At Panel 8F/9F: | |||
* UNIT START and UNIT IDLE lights are extinguished | |||
* All EDG 1 alarms in their normal state (no alarms) | |||
* The EDG 1 MODE SELECTOR switch is in the PEAKING position Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: 4 (step 6.7) | Performance Step: 4 (step 6.7) | ||
Standard: Verifies an Equipment Operator at EDG 1 prior to starting EDG 1. | Standard: Verifies an Equipment Operator at EDG 1 prior to starting EDG 1. | ||
BOOTH CUE: As the Equipment | BOOTH CUE: As the Equipment Operator, report that you are at EDG 1 standing-by. | ||
NOTE: The next procedure step (step 6.8) is only a caution/note. | NOTE: The next procedure step (step 6.8) is only a caution/note. | ||
Comment: | Comment: | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
9 Performance Step: 5 (step 6.9) | |||
Standard: To start the EDG At Panel 8F/9F, momentarily places EDG 1 NORMAL START switch to the START position. | |||
NOTE: EDG will idle for approximately 90 seconds then accelerate to 900 RPM. EDG will then automatically synchronize, the breaker will close, and it will automatically achieve rated load (2750 KW). | |||
NRC Sim6 Page 4 of 10 | |||
Appendix C Form ES-C-1 Performance Information Comment: | |||
Appendix C Form ES-C- | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: 6 (step 6.10) | |||
Standard: Verifies EDG start at Panel 8F/9F, by observing UNIT START and UNIT IDLING lights illuminate. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: 7 (step 6.11) | Performance Step: 7 (step 6.11) | ||
Standard: Verifies proper creepy crank operation with the EO. | Standard: Verifies proper creepy crank operation with the EO. | ||
BOOTH CUE: As the Equipment Operator, | BOOTH CUE: As the Equipment Operator, report proper creepy crank operation. | ||
Comment:_________________________________________________________________________________ | Comment: | ||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: 8 (step 6.12) | |||
NRC Sim6 Page 5 of 10 | |||
Appendix C Form ES-C-1 Standard: Verifies EDG 1 automatically comes up to speed, automatically synchronizes with the line, EDG 1 load breaker closes (red light ON, green light OFF) and begins to pickup load (DG KW, KVAR, Amps rise on Panel 8F/9F) | |||
Performance Information Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
Performance Step: 9 (step 6.13) | |||
Standard: Observes EDG load rises automatically to approximately 2750 KW and records the initial full load achieved (acceptable range is 2600-2800 KW). | |||
FLOOR CUE: EDG1 KW loading indicates 2850 KW Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
9 Performance Step: 10 (step 6.14.1 / 6.14.2) | |||
Standard: 1) Places EDG 1 MODE SELECTOR switch to TRANSFER position. | |||
: 2) Adjusts load to 2750 KW using the EDG1 GOVERNOR CONTROL switch to LOWER. | |||
FLOOR CUE: (AFTER a small adjustment) EDG1 KW loading indicates 2700 KW Note: Procedure steps 6.15 and 6.16 are not applicable. | |||
Comment: | |||
NRC Sim6 Page 6 of 10 | |||
Appendix C Form ES-C-1 | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
Performance Information Performance Step: 11 (step 6.17) | |||
Standard: Records time that load level of 2600-2800 KW was attained. | |||
Comment: | Comment: | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: 12 (step 6.18) | |||
Comment: | Standard: Adjusts KVAR load by adjusting the VOLTAGE/KVAR CONTROL switch to obtain approximately +1000 KVAR (lagging) (acceptable range is +200 to | ||
+2000 KVAR lagging). | |||
NOTE: KVAR load should be within the acceptable range of +200 to +2000. The Candidate may/may not adjust from within this range to attain +1000 KVAR. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
9 Performance Step: 13 NOTE: Input ANN-T-6-b, EDG1 ENG TEMP HI, at this time. | |||
NRC Sim6 Page 7 of 10 | |||
Appendix C Form ES-C-1 Standard: Responds to annunciator T6b: EDG1 ENG TEMP HI | |||
Appendix C Form ES-C- | |||
: 1) May direct the Equipment Operator to verify proper louver operation. | : 1) May direct the Equipment Operator to verify proper louver operation. | ||
: 2) Trips the EDG by placing the NORMAL START switch to the STOP position (KW, KVAR, amps lower; EDG1 breaker opens [red light OFF, green light ON]). | : 2) Trips the EDG by placing the NORMAL START switch to the STOP position (KW, KVAR, amps lower; EDG1 breaker opens [red light OFF, green light ON]). | ||
BOOTH CUE: (As the Equipment Operator) | BOOTH CUE: (As the Equipment Operator) The EDG1 louvers are full open. | ||
The EDG1 louvers are full open. | Performance Information Comment: | ||
Performance Information Comment:_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Terminating Cue: Following startup/loading of EDG1 for surveillance, EDG1 has been shutdown by the Candidate. | |||
JPM Stop Time: ____________ | JPM Stop Time: ____________ | ||
NRC Sim6 Page 8 of 10 | |||
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Sim6 Examinees Name: __________________ | |||
Examiners Name: __________________ | |||
Date Performed: __________________ | Date Performed: __________________ | ||
Facility Evaluator: __________________ | |||
Number of Attempts: __________________ | |||
Time to Complete: __________________ | |||
Question: | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
===Response=== | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________ | |||
NRC Sim6 Page 9 of 10 | |||
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions: | |||
: 1. The Reactor is at 100% power, all systems normally aligned. | |||
: 2. All items listed in Prerequisite Section 3.0 of Procedure 636.4.003, Diesel Generator #1 Load Test, have been verified. | |||
: 3. Steps 6.1 through 6.5 of Procedure 636.4.003 have been completed. | |||
: 4. The System Dispatcher has been contacted and grid conditions are stable. | |||
: 5. An EO has been briefed, has a copy of the procedure and is stationed at EDG 1 with a radio. | |||
Task Cue: | |||
Beginning with step 6.6, perform Diesel Generator #1 Load Test IAW Procedure 636.4.003 for scheduled surveillance. | |||
NRC Sim6 Page 10 of 10 | |||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2180401001 Task Title: Perform EMRV Operability Test w/ Stuck Open EMRV (Alternate Path) | |||
Appendix C Job Performance Measure Form ES-C- | |||
Job Performance Measure No: NRC Sim7 (RO/SRO) | Job Performance Measure No: NRC Sim7 (RO/SRO) | ||
K/A | K/A | ||
==Reference:== | ==Reference:== | ||
239002 A2.03 (RO 4.1/SRO 4.2)Examinee: | 239002 A2.03 (RO 4.1/SRO 4.2) | ||
Facility Evaluator: | Examinee: ___________________ NRC Examiner: ___________________ | ||
Method of Testing:Simulated Performance | Facility Evaluator: ___________________ Date: _________ | ||
Read to the Examinee:I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.Initial Conditions:1. A reactor startup is in progress.2. Reactor power is less that 5%. | Method of Testing: | ||
Simulated Performance Actual Performance X Classroom _________ Simulator X Plant _________ | |||
Read to the Examinee: | |||
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied. | |||
Initial Conditions: | |||
: 1. A reactor startup is in progress. | |||
: 2. Reactor power is less that 5%. | |||
: 3. Reactor water level, power, and pressure are constant. | : 3. Reactor water level, power, and pressure are constant. | ||
: 4. RPV water level control is in manual , and will be controlled by another Operator.5. EMRV Operability Testing is required for valve NR-108A only.6. Procedure steps 6.1 through 6.24 of 602.4.003, Electromatic Relief Valve Operability Test, have been completed for EMRV NR-108A.Task Standard:The EMRV has been closed when the NR-108A EMRV Normal/Disable keylock switch has been placed in DISABLE. | : 4. RPV water level control is in manual, and will be controlled by another Operator. | ||
Appendix C Job Performance Measure Form ES-C- | : 5. EMRV Operability Testing is required for valve NR-108A only. | ||
: 6. Procedure steps 6.1 through 6.24 of 602.4.003, Electromatic Relief Valve Operability Test, have been completed for EMRV NR-108A. | |||
Task Standard: The EMRV has been closed when the NR-108A EMRV Normal/Disable keylock switch has been placed in DISABLE. | |||
NRC Sim7 Page 1 of 9 | |||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Required Materials: | |||
: 1. Stopwatch | |||
: 2. Prepared copy of 602.4.003 (completed up through step 6.24) | : 2. Prepared copy of 602.4.003 (completed up through step 6.24) | ||
General | General | ||
==References:== | ==References:== | ||
: 1. 602.4.003, Electromatic Relief Valve Operability Test, Rev. | : 1. 602.4.003, Electromatic Relief Valve Operability Test, Rev. 29 | ||
Time Critical Task: No Validation Time: 23 minutes | : 2. ABN-40, Stuck Open EMRV, Rev. 2 Initiating Cue: Complete procedure 602.4.003, Electromatic Relief Valve Operability Test for EMRV NR-108A, beginning at step 6.25. | ||
Time Critical Task: No Validation Time: 23 minutes Simulator Setup: | |||
: 1. Low power IC (about 5% power, but is not required) | |||
: 2. FW Control in manual | |||
: 3. Select EMRV NR018A for tail-piece indication on 1F/2F | |||
: 4. EMRV 108A control switch stuck in the MAN position (open) AFTER the valve is opened: SWI-ADS001C to ON NRC Sim7 Page 2 of 9 | |||
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________ | |||
Standard: Provide repeat back of initiating cue. Evaluator acknowledges repeat back. | |||
Standard: Provide repeat | Comment: | ||
Evaluator acknowledges repeat back. | ________________________________________________________________________ | ||
Comment: | ________________________________________________________________________ | ||
________________________________________________________________________ | |||
Performance Step: 2 Standard: Reviews Precautions and Limitations. | Performance Step: 2 Standard: Reviews Precautions and Limitations. | ||
Comment: | Comment: | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Sim7 Page 3 of 9 | |||
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 3 (step 6.25) | |||
FLOOR CUE: Tell the Candidate that you will record the valve stroke times for him. | |||
Standard: At Panel 1F/2F, places the control switch for EMRV NR-108A in the MAN position and starts the stopwatch (red light ON; green light OFF). | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
Performance Step: 4 (step 6.26) | |||
Standard: When annunciator SV/EMRV NOT CLOSED (B-4-g) alarms, stop the stopwatch; records time on Attachment 602.4.003-1 (See CUE in Step 4). | |||
At Panel 1F/2F, verifies: | |||
* Red light is lit and green light is extinguished for EMRV NR-108A. | |||
* Acoustic valve monitor is in the valve open region. | |||
* Annunciator EMRV OPEN (B-3-g) is in alarm. | |||
NOTE: After the EMRV is manually opened, insert malfunction SWI-ADS001C to ON (this prevents the valve from being manually closed). | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
NRC Sim7 Page 4 of 9 | |||
Appendix C Form ES-C-1 Performance Information Performance Step: 5 (step 6.27) | |||
NOTE: The EMRV will NOT close at this time and remains open. | |||
Standard: At Panel 1F/2F, 5 seconds after opening NR-108A, places its control switch in the AUTO position and starts the stopwatch. | |||
Reports/recognizes EMRV will not close (red light ON, green light OFF; acoustic monitor still shows in the Valve Open Region (red); annunciators still in alarm), and enters ABN-40, Stuck Open EMRV. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: 6 (step 3.1 of ABN-40)Standard:Verifies EMRV open (by any of the following): red light ON, acoustic monitor shows valve open (red region), | Performance Step: 6 (step 3.1 of ABN-40) | ||
Comment: | Standard: Verifies EMRV open (by any of the following): red light ON, acoustic monitor shows valve open (red region), EMRV discharge temperature high. | ||
CUE: If requested to verify EMRV tailpiece temperature on RB 23, report the temperature is about 320° F. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Sim7 Page 5 of 9 | |||
Appendix C Form ES-C-1 Performance Information Performance Step: 7 (step 3.2) | |||
Standard: Verifies Feedwater Control in Manual CUE: Another Operator has confirmed Manual Control on the Master Controller and will be controlling feedwater. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: | Performance Step: 8 (step 3.2.3/3.2.4) | ||
Standard: At Panel 1F/2F, places EMRV NR-108A control switch in the OFF position; recognizes EMRV is still open (acoustic monitor still in the RED area; valve red light still ON; annunciators still lit; tailpiece temperature still high). | |||
Comment: | Comment: | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
Performance Step: 9 (step 3.2.5/3.2.6) | |||
Standard: At Panel 1F/2F, cycles EMRV NR-108A control switch from OFF to MAN to OFF another 3-5 times in an attempt to close the EMRV; recognizes EMRV is still open (acoustic monitor still in the RED area; valve red light still ON; annunciators still lit; tailpiece temperature still high). | |||
Comment: | |||
NRC Sim7 Page 6 of 9 | |||
Appendix C Form ES-C-1 | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Information Performance Step: | _________________________________________________________________________________ | ||
10 (step 3.2.7)NOTE:When the Normal/Disable keylock switch is placed in DISABLE, red/green position indication | _________________________________________________________________________________ | ||
Performance Information 9 Performance Step: 10 (step 3.2.7) | |||
NOTE: When the Normal/Disable keylock switch is placed in DISABLE, red/green position indication lights for the valve are lost on Panel 1F/2F. | |||
Standard: In the rear of Panel 1F/2F, places NR-108A EMRV Normal/Disable keylock switch in DISABLE. Verifies EMRV closes (acoustic monitor in the Valve Closed Region (white); tailpiece temperature lowering). | |||
Reports that the EMRV is closed (not required for critical task). | Reports that the EMRV is closed (not required for critical task). | ||
FLOOR CUE: Acknowledge the report. | FLOOR CUE: Acknowledge the report. | ||
Note: This action will close the EMRV. | Note: This action will close the EMRV. | ||
Comment:_________________________________________________________________________________ | Comment: | ||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
Terminating Cue: The EMRV has been closed when the NR-108A EMRV Normal/Disable keylock switch has been placed in DISABLE. | |||
JPM Stop Time: ____________ | JPM Stop Time: ____________ | ||
NRC Sim7 Page 7 of 9 | |||
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Sim7 Examinees Name: __________________ | |||
Examiners Name: __________________ | |||
Date Performed: __________________ | Date Performed: __________________ | ||
Facility Evaluator: __________________ | Facility Evaluator: __________________ | ||
Number of Attempts: __________________ | |||
Time to Complete: __________________ | |||
Question: | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
===Response=== | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________ | |||
NRC Sim7 Page 8 of 9 | |||
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions: | |||
: 1. A reactor startup is in progress. | |||
: 2. Reactor power is less that 5%. | |||
Appendix C Form ES-C- | |||
: 3. Reactor water level, power, and pressure are constant. | : 3. Reactor water level, power, and pressure are constant. | ||
: 4. RPV water level control is in manual , and will be controlled by another Operator.5. EMRV Operability Testing is required for valve NR-108A only.6. Procedure steps 6.1 through 6.24 of 602.4.003, Electromatic Relief Valve Operability Test, have been completed for EMRV NR-108A. | : 4. RPV water level control is in manual, and will be controlled by another Operator. | ||
Task Cue: Complete procedure 602.4.003, Electromatic Relief Valve Operability Test for EMRV NR-108A, | : 5. EMRV Operability Testing is required for valve NR-108A only. | ||
Appendix C Job Performance Measure Form ES-C- | : 6. Procedure steps 6.1 through 6.24 of 602.4.003, Electromatic Relief Valve Operability Test, have been completed for EMRV NR-108A. | ||
Task Cue: | |||
Complete procedure 602.4.003, Electromatic Relief Valve Operability Test for EMRV NR-108A, beginning at step 6.25. | |||
NRC Sim7 Page 9 of 9 | |||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2180401001 Task Title: Perform EMRV Operability Test w/ Stuck Open EMRV (Alternate Path) | |||
Job Performance Measure No: NRC Sim7 (RO/SRO) | Job Performance Measure No: NRC Sim7 (RO/SRO) | ||
K/A | K/A | ||
==Reference:== | ==Reference:== | ||
239002 A2.03 (RO 4.1/SRO 4.2)Examinee: | 239002 A2.03 (RO 4.1/SRO 4.2) | ||
Facility Evaluator: | Examinee: ___________________ NRC Examiner: ___________________ | ||
Method of Testing:Simulated Performance | Facility Evaluator: ___________________ Date: _________ | ||
Read to the Examinee:I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.Initial Conditions:1. A reactor startup is in progress.2. Reactor power is less that 5%. | Method of Testing: | ||
Simulated Performance Actual Performance X Classroom _________ Simulator X Plant _________ | |||
Read to the Examinee: | |||
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied. | |||
Initial Conditions: | |||
: 1. A reactor startup is in progress. | |||
: 2. Reactor power is less that 5%. | |||
: 3. Reactor water level, power, and pressure are constant. | : 3. Reactor water level, power, and pressure are constant. | ||
: 4. RPV water level control is in manual , and will be controlled by another Operator.5. EMRV Operability Testing is required for valve NR-108A only.6. Procedure steps 6.1 through 6.24 of 602.4.003, Electromatic Relief Valve Operability Test, have been completed for EMRV NR-108A.Task Standard:The EMRV has been closed when the NR-108A EMRV Normal/Disable keylock switch has been placed in DISABLE. | : 4. RPV water level control is in manual, and will be controlled by another Operator. | ||
Appendix C Job Performance Measure Form ES-C- | : 5. EMRV Operability Testing is required for valve NR-108A only. | ||
: 6. Procedure steps 6.1 through 6.24 of 602.4.003, Electromatic Relief Valve Operability Test, have been completed for EMRV NR-108A. | |||
Task Standard: The EMRV has been closed when the NR-108A EMRV Normal/Disable keylock switch has been placed in DISABLE. | |||
NRC Sim7 Page 1 of 9 | |||
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Required Materials: | |||
: 1. Stopwatch | |||
: 2. Prepared copy of 602.4.003 (completed up through step 6.24) | : 2. Prepared copy of 602.4.003 (completed up through step 6.24) | ||
General | General | ||
==References:== | ==References:== | ||
: 1. 602.4.003, Electromatic Relief Valve Operability Test, Rev. | : 1. 602.4.003, Electromatic Relief Valve Operability Test, Rev. 29 | ||
Time Critical Task: No Validation Time: 23 minutes | : 2. ABN-40, Stuck Open EMRV, Rev. 2 Initiating Cue: Complete procedure 602.4.003, Electromatic Relief Valve Operability Test for EMRV NR-108A, beginning at step 6.25. | ||
Time Critical Task: No Validation Time: 23 minutes Simulator Setup: | |||
: 1. Low power IC (about 5% power, but is not required) | |||
: 2. FW Control in manual | |||
: 3. Select EMRV NR018A for tail-piece indication on 1F/2F | |||
: 4. EMRV 108A control switch stuck in the MAN position (open) AFTER the valve is opened: SWI-ADS001C to ON NRC Sim7 Page 2 of 9 | |||
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________ | |||
Standard: Provide repeat back of initiating cue. Evaluator acknowledges repeat back. | |||
Standard: Provide repeat | Comment: | ||
Evaluator acknowledges repeat back. | ________________________________________________________________________ | ||
Comment: | ________________________________________________________________________ | ||
________________________________________________________________________ | |||
Performance Step: 2 Standard: Reviews Precautions and Limitations. | Performance Step: 2 Standard: Reviews Precautions and Limitations. | ||
Comment: | Comment: | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Sim7 Page 3 of 9 | |||
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 3 (step 6.25) | |||
FLOOR CUE: Tell the Candidate that you will record the valve stroke times for him. | |||
Standard: At Panel 1F/2F, places the control switch for EMRV NR-108A in the MAN position and starts the stopwatch (red light ON; green light OFF). | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
Performance Step: 4 (step 6.26) | |||
Standard: When annunciator SV/EMRV NOT CLOSED (B-4-g) alarms, stop the stopwatch; records time on Attachment 602.4.003-1 (See CUE in Step 4). | |||
At Panel 1F/2F, verifies: | |||
* Red light is lit and green light is extinguished for EMRV NR-108A. | |||
* Acoustic valve monitor is in the valve open region. | |||
* Annunciator EMRV OPEN (B-3-g) is in alarm. | |||
NOTE: After the EMRV is manually opened, insert malfunction SWI-ADS001C to ON (this prevents the valve from being manually closed). | |||
Comment: | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | |||
NRC Sim7 Page 4 of 9 | |||
Appendix C Form ES-C-1 Performance Information Performance Step: 5 (step 6.27) | |||
NOTE: The EMRV will NOT close at this time and remains open. | |||
Standard: At Panel 1F/2F, 5 seconds after opening NR-108A, places its control switch in the AUTO position and starts the stopwatch. | |||
Reports/recognizes EMRV will not close (red light ON, green light OFF; acoustic monitor still shows in the Valve Open Region (red); annunciators still in alarm), and enters ABN-40, Stuck Open EMRV. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: 6 (step 3.1 of ABN-40)Standard:Verifies EMRV open (by any of the following): red light ON, acoustic monitor shows valve open (red region), | Performance Step: 6 (step 3.1 of ABN-40) | ||
Comment: | Standard: Verifies EMRV open (by any of the following): red light ON, acoustic monitor shows valve open (red region), EMRV discharge temperature high. | ||
CUE: If requested to verify EMRV tailpiece temperature on RB 23, report the temperature is about 320° F. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
NRC Sim7 Page 5 of 9 | |||
Appendix C Form ES-C-1 Performance Information Performance Step: 7 (step 3.2) | |||
Standard: Verifies Feedwater Control in Manual CUE: Another Operator has confirmed Manual Control on the Master Controller and will be controlling feedwater. | |||
Comment: | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Step: | Performance Step: 8 (step 3.2.3/3.2.4) | ||
Standard: At Panel 1F/2F, places EMRV NR-108A control switch in the OFF position; recognizes EMRV is still open (acoustic monitor still in the RED area; valve red light still ON; annunciators still lit; tailpiece temperature still high). | |||
Comment: | Comment: | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
Performance Step: 9 (step 3.2.5/3.2.6) | |||
Standard: At Panel 1F/2F, cycles EMRV NR-108A control switch from OFF to MAN to OFF another 3-5 times in an attempt to close the EMRV; recognizes EMRV is still open (acoustic monitor still in the RED area; valve red light still ON; annunciators still lit; tailpiece temperature still high). | |||
Comment: | |||
NRC Sim7 Page 6 of 9 | |||
Appendix C Form ES-C-1 | |||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
Performance Information Performance Step: | _________________________________________________________________________________ | ||
10 (step 3.2.7)NOTE:When the Normal/Disable keylock switch is placed in DISABLE, red/green position indication | Performance Information 9 Performance Step: 10 (step 3.2.7) | ||
NOTE: When the Normal/Disable keylock switch is placed in DISABLE, red/green position indication lights for the valve are lost on Panel 1F/2F. | |||
Standard: In the rear of Panel 1F/2F, places NR-108A EMRV Normal/Disable keylock switch in DISABLE. Verifies EMRV closes (acoustic monitor in the Valve Closed Region (white); tailpiece temperature lowering). | |||
Reports that the EMRV is closed (not required for critical task). | Reports that the EMRV is closed (not required for critical task). | ||
FLOOR CUE: Acknowledge the report. | FLOOR CUE: Acknowledge the report. | ||
Note: This action will close the EMRV. | Note: This action will close the EMRV. | ||
Comment:_________________________________________________________________________________ | Comment: | ||
_________________________________________________________________________________ | |||
_________________________________________________________________________________ | _________________________________________________________________________________ | ||
_________________________________________________________________________________ | |||
Terminating Cue: The EMRV has been closed when the NR-108A EMRV Normal/Disable keylock switch has been placed in DISABLE. | |||
JPM Stop Time: ____________ | JPM Stop Time: ____________ | ||
NRC Sim7 Page 7 of 9 | |||
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Sim7 Examinees Name: __________________ | |||
Examiners Name: __________________ | |||
Date Performed: __________________ | Date Performed: __________________ | ||
Facility Evaluator: __________________ | Facility Evaluator: __________________ | ||
Number of Attempts: __________________ | |||
Time to Complete: __________________ | |||
Question: | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
===Response=== | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
_______________________________________________________________________ | |||
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________ | |||
NRC Sim7 Page 8 of 9 | |||
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions: | |||
: 1. A reactor startup is in progress. | |||
: 2. Reactor power is less that 5%. | |||
Appendix C Form ES-C- | |||
: 3. Reactor water level, power, and pressure are constant. | : 3. Reactor water level, power, and pressure are constant. | ||
: 4. RPV water level control is in manual , and will be controlled by another Operator.5. EMRV Operability Testing is required for valve NR-108A only.6. Procedure steps 6.1 through 6.24 of 602.4.003, Electromatic Relief Valve Operability Test, have been completed for EMRV NR-108A. | : 4. RPV water level control is in manual, and will be controlled by another Operator. | ||
Task Cue: Complete procedure 602.4.003, Electromatic Relief Valve Operability Test for EMRV NR-108A, | : 5. EMRV Operability Testing is required for valve NR-108A only. | ||
: 6. Procedure steps 6.1 through 6.24 of 602.4.003, Electromatic Relief Valve Operability Test, have been completed for EMRV NR-108A. | |||
Task Cue: | |||
Complete procedure 602.4.003, Electromatic Relief Valve Operability Test for EMRV NR-108A, beginning at step 6.25. | |||
NRC Sim7 Page 9 of 9}} |
Revision as of 12:23, 23 November 2019
ML063070449 | |
Person / Time | |
---|---|
Site: | Oyster Creek |
Issue date: | 09/15/2006 |
From: | AmerGen Energy Co |
To: | D'Antonio J Operations Branch I |
Sykes, Marvin D. | |
References | |
Download: ML063070449 (98) | |
Text
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2090501403/2090504401 Task Title: Align the Core Spray System to the Condensate Storage Tank for Emergency Operations Job Performance Measure No: NRC Plant1 (RO/SRO)
K/A
Reference:
295030 G2.1.30 (RO 3.7/SRO 4.4)
Examinee: ___________________ NRC Examiner: ___________________
Facility Evaluator: ___________________ Date: _________
Method of Testing:
Simulated Performance X Actual Performance ________________
Classroom _________ Simulator _________ Plant X Read to the Examinee:
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.
Initial Conditions:
- 1. The Reactor is shutdown.
- 2. Reactor water level is being maintained at 160 inches with feedwater.
- 3. Drywell pressure is 1.1 psig and stable.
- 4. Torus water level is 140 inches and lowering due to a leak.
- 5. The Reactor Building is accessible.
- 6. Core Spray System 1 is operable and available.
Task Standard: Making-up to the Torus from the CST via Core Spray System 1 in accordance with Support Procedure 37.
Required Materials: MB-1 and PA-2235 keys (simulated)
NRC Plant1 Page 1 of 8
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET General
References:
Support Procedure 37 of EMG-3200.02, Primary Containment Control, Rev. 17 Initiating Cue: Line up and add makeup to the torus from the CST via Core Spray System 1 in accordance with Support Procedure 37.
Time Critical Task: No Validation Time: 40 minutes NRC Plant1 Page 2 of 8
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: __________
Standard: Provides repeat back of initiating cue. Evaluator acknowledges repeat back.
Comment:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Performance Step: 2 Standard: Verifies Prerequisites.
Comment:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
NRC Plant1 Page 3 of 8
Appendix C Form ES-C-1 Performance Information Performance Step: 3 (step 3.2.4.1)
CUE: Report that the following steps have been completed:
- System 1 Core Spray Main Pumps and Booster Pumps are stopped (step 3.2.1)
- Core Spray System suction valves V-20-3 and V-20-32 are closed (step 3.2.2)
- Core Spray System 1 Parallel Isolation valves V-20-15 and V-20-40 are closed (step 3.2.3)
Standard: Places the Core Spray pump suction valve breakers in OFF:
CUE: The breakers for valve V-20-3 and V-20-32 are in the OFF position.
Comment:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
9 Performance Step: 4 (step 3.2.4.2)
Standard: Using MB-1 key, unlocks and opens the following CST valves:
- V-20-1 (NW corner Room)
- V-20-5 (NW corner Room)
- V-20-34 (NW corner Room)
CUE: Valves V-20-1, V-20-5, and V-20-34 are unlocked and open.
NOTE: If the Candidate does not have the proper keys, ask where they can be obtained:
the Controlled Key Locker in the Shift Managers Office. (Not required to go get the key)
Comment:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
NRC Plant1 Page 4 of 8
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 5 (step 3.2.4.3)
Standard: Calls the Control Room to start Core Spray System 1 main pump NZ01A or NZ01C.
CUE: Acknowledge the report. State that Core Spray Pump NZ01A has been started and is running.
Comment:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
9 Performance Step: 6 (step 3.2.6)
Standard: Using the MB-1 key, unlocks and places the breaker for V-20-27 in the ON position (MCC 1A21B RB 23 E).
CUE: V-20-27 breaker is ON.
Comment:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
9 Performance Step: 7 (step 3.2.7)
Standard: On RB 51' NW, uses the PA-2235 key to open Torus Test Flow Return valve V-20-27 by placing upper keylock switch to the OPEN position (red light ON).
CUE: Valve V-20-27 indicates full open (red light on). (See comment regarding KEYS in Step 4)
Comment:
NRC Plant1 Page 5 of 8
Appendix C Form ES-C-1
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Performance Information Performance Step: 8 Standard: Calls the Control Room to report that makeup to the Torus is in progress.
CUE: (As Reactor Operator) repeat back the operators report.
Comment:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Terminating Cue: Making-up to the Torus from the CST via Core Spray System 1 in accordance with Support Procedure 37.
JPM Stop Time: _________________
NRC Plant1 Page 6 of 8
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Plant1 Examinees Name: __________________
Examiners Name: __________________
Date Performed: __________________
Facility Evaluator: __________________
Number of Attempts: __________________
Time to Complete: __________________
Question:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Response
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________
NRC Plant1 Page 7 of 8
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions:
- 1. The Reactor is shutdown.
- 2. Reactor water level is being maintained at 160 inches with feedwater.
- 3. Drywell pressure is 1.1 psig and stable.
- 4. Torus water level is 140 inches and lowering due to a leak.
- 5. The Reactor Building is accessible.
- 6. Core Spray System 1 is operable and available.
Task Cue:
Line up and add makeup to the torus from the CST via Core Spray System 1 in accordance with Support Procedure 37.
THIS JPM IS SIMULATE ONLY. THERE WILL BE NO MANIPULATIONS OF PLANT COMPONENTS.
NRC Plant1 Page 8 of 8
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2630101003/2630104009 Task Title: Shift Battery Chargers Job Performance Measure No: NRC Plant2 (RO/SRO)
K/A
Reference:
263000 K1.02 (RO 3.2/SRO 3.3)
Examinee: ___________________ NRC Examiner: ___________________
Facility Evaluator: ___________________ Date: _________
Method of Testing:
Simulated Performance X Actual Performance _______________
Classroom _________ Simulator _________ Plant X Read to the Examinee:
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.
Initial Conditions:
- 1. Static Charger C1 is currently in service supplying DC-C.
- 2. Electricians need to perform scheduled maintenance on Static Charger C1 while still energized from its AC source.
- 3. Static Charger C2 has been verified to be in standby readiness.
- 4. Isolation Condenser valves V-14-33 and V-14-35 have been declared inoperable and the appropriate Tech Spec LCOs have been entered by the Control Room SRO.
Task Standard: Static Charger C1 is removed from service and Static Charger C2 is in service.
Required Materials: None General
References:
Procedure 340.3, 125 Volt DC Distribution System C, Rev. 27 NRC Plant2 Page 1 of 9
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Initiating Cue: Transfer operation from Static Charger C1 to Static Charger C2 IAW Procedure 340.3, 125 Volt DC Distribution System C, Section 6.0.
Time Critical Task: No Validation Time: 16 minutes NRC Plant2 Page 2 of 9
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ___________
Standard: Provides repeat back of initiating cue. Evaluator acknowledges repeat back.
Comment:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Performance Step: 2 Standard: Verifies Prerequisites and reviews Precautions and Limitations.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Plant2 Page 3 of 9
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 3 (step 6.3.3.1)
Standard: Places the DC output breaker for Charger C1 (at charger cabinet) in the OFF position (Labeled DC POWER).
CUE: The DC output breaker for Charger C1 is in the OFF position.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 4 (step 6.3.3.2)
Standard: Places the breaker for Charger C1 on DC-C (in 4160V Room) in the OFF position.
CUE: The breaker for Charger C1 on DC-C (in 4160V Room) in the OFF position (Labeled C1 STATIC CHARGER OUTPUT BREAKER).
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 5 (step 6.3.4.1)
Standard: Places the breaker for Charger C2 on DC-C (in 4160V Room) in the ON position (Labeled C1 STATIC CHARGER OUTPUT BREAKER).
CUE: The breaker for Charger C2 on DC-C (in 4160V Room) is in the ON position.
Comment:
NRC Plant2 Page 4 of 9
Appendix C Form ES-C-1
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Plant2 Page 5 of 9
Appendix C Form ES-C-1 Performance Information Performance Step: 6 (step 6.3.4.2)
Standard: Checks Charger C2 voltage against Battery Bus voltage.
CUE: Charger C2 output voltage is 2 volts LESS THAN Battery Bus voltage.
Standard: Adjusts the charger output voltage (float) in the direction to raise charger voltage to match or be slightly above bus voltage.
CUE: Charger voltage is now EQUAL TO bus voltage.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 7 (step 6.3.4.3)
Standard: Places the DC output breaker for Charger C2 (at charger cabinet) in the ON position.
CUE: The DC output breaker for Charger C2 (at charger cabinet) in the ON position (Labeled DC POWER).
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Plant2 Page 6 of 9
Appendix C Form ES-C-1 Performance Information Performance Step: 8 (step 6.3.5)
Standard: Checks Battery Bus voltage to maintain DC System voltage 130.2 - 135 volts.
CUE: DC Battery Bus voltage indicates 133 volts (no adjustments are required).
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 9 (steps 6.3.6, 6.3.7, and 6.3.8)
Standard: Calls the Control Room to report Static Charger C2 is supplying DC-C.
Requests they declare V-14-33 and V-14-35 operable and exit the applicable Tech Specs.
CUE: (As the Control Room) V-14-33 and V-14-35 have been declared operable; Tech Spec 3.7.D.1, 3.8.C and 3.8.E have been exited.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Terminating Cue: Static Charger C1 has been removed from service and Static Charger C2 has been placed into service.
JPM Stop Time: ___________
NRC Plant2 Page 7 of 9
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Plant2 Examinees Name: __________________
Examiners Name: __________________
Date Performed: __________________
Facility Evaluator: __________________
Number of Attempts: __________________
Time to Complete: __________________
Question:
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Response
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________
NRC Plant2 Page 8 of 9
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions:
- 1. Static Charger C1 is currently in service supplying DC-C.
- 2. Electricians need to perform scheduled maintenance on Static Charger C1 while still energized from its AC source.
- 3. Static Charger C2 has been verified to be in standby readiness.
- 4. Isolation Condenser valves V-14-33 and V-14-35 have been declared inoperable and the appropriate Tech Spec LCOs have been entered by the Control Room SRO.
Task Cue:
Transfer operation from Static Charger C1 to Static Charger C2 IAW Procedure 340.3, 125 Volt DC Distribution System C, Section 6.0.
THIS JPM IS SIMULATE ONLY. THERE WILL BE NO MANIPULATIONS OF PLANT COMPONENTS.
NRC Plant2 Page 9 of 9
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2860401402/2070501401/2070504401 Task Title: Lineup Fire Protection to the Isolation Condensers Job Performance Measure No: NRC Plant3 (RO/SRO)
K/A
Reference:
286000 G2.4.35 (RO 3.3/SRO 3.5)
Examinee: ___________________ NRC Examiner: ___________________
Facility Evaluator: ___________________ Date: _________
Method of Testing:
Simulated Performance X Actual Performance ________________
Classroom _________ Simulator _________ Plant X Read to the Examinee:
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.
Initial Conditions:
- 1. The Reactor is scrammed and isolated.
- 2. Condensate transfer pump A is out of service.
- 3. Condensate transfer pump B has failed.
- 4. Isolation Condenser A has initiated from the standby readiness condition.
- 5. The Fire Water System is operable and available.
Task Standard: Fire Protection System lined up to Isolation Condenser A Required Materials: Fire Protection key (simulated)
General
References:
Procedure 307, Isolation Condenser System, Rev. 92 Initiating Cue: Lineup the Fire Protection System to makeup to Isolation Condenser A in accordance with Procedure 307, Isolation Condenser System, Section 7.0.
Notify the Control Room when the line-up is complete.
NRC Plant3 Page 1 of 7
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Time Critical Task: No Validation Time: 16 minutes Note: Some simulated valve manipulations occur in a contaminated area. The Candidate is NOT to reach across the contamination barrier.
NRC Plant3 Page 2 of 7
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________
Standard: Provide repeat back of initiating cue. Evaluator acknowledges repeat back.
Comment:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Performance Step: 2 Standard: Verify Prerequisites and reviews Precautions and Limitations.
CUE: All prerequisites have been met, Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Plant3 Page 3 of 7
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 3 (step 7.3.2.1)
Standard: Closes Isolation Condenser Supply Isolation Valve V-11-41 on Reactor Building 23' elevation East.
CUE: Valve V-11-41 is closed.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 4 (step 7.3.2.2)
Standard: Closes Makeup to Isolation Condenser Telltale Drain Valve V-11-63 on Reactor Building 23' elevation East.
CUE: Valve V-11-63 is closed.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 5 (step 7.3.2.3)
Standard: Using the Fire Protection key, unlocks and opens Fire Protection to Isolation Condenser Cross-Tie Isolation Valve V-9-2099 on Reactor Building 23' elevation East.
CUE: Valve V-9-2099 is unlocked and open. Note: If the Candidate does not have the key to unlock this valve, ask where the appropriate key can be obtained: the key can be obtained from the Controlled Key Locker in the Shift Managers Office (NOT required to go back for the key).
NRC Plant3 Page 4 of 7
Appendix C Form ES-C-1 Performance Information Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 6 (step 7.3.2.4)
Standard: Opens Fire Protection to Isolation Condenser Makeup Valve V-11-49 on Reactor Building 23' elevation East.
CUE: Valve V-11-49 is open.
NOTE: This completes the in-plant lineup for CST to Isolation Condenser A. The Candidate should report in this step or next, that the in-plant lineup is complete.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 8 (step 7.3.2.5)
Standard: Requests Control Room record initial isolation condenser shell level.
CUE: Shell water level will be recorded.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Plant3 Page 5 of 7
Appendix C Form ES-C-1 Terminating Cue: Fire Protection System is lined up to Isolation Condenser A JPM Start Time: ____________
Validation of Completion Job Performance Measure No. NRC Plant3 Examinees Name: __________________
Examiners Name: __________________
Date Performed: __________________
Facility Evaluator: __________________
Number of Attempts: __________________
Time to Complete: __________________
Question:
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Response
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________
NRC Plant3 Page 6 of 7
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions:
- 1. The Reactor is scrammed and isolated.
- 2. Condensate transfer pump A is out of service.
- 3. Condensate transfer pump B has failed.
- 4. Isolation Condenser A has initiated from the standby readiness condition.
- 5. The Fire Water System is operable and available.
Task Cue:
Lineup the Fire Protection System to makeup to Isolation Condenser A in accordance with Procedure 307, Isolation Condenser System, Section 7.0. Notify the Control Room when the line-up is complete.
THIS JPM IS SIMULATE ONLY. THERE WILL BE NO MANIPULATIONS OF PLANT COMPONENTS.
NRC Plant3 Page 7 of 7
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2020601002 Task Title: Respond to Power Oscillations (Recirc. Flow Oscillations) (Alternate Path)
Job Performance Measure No: NRC Sim1 (RO/SRO)
K/A
Reference:
202002 A2.04 (RO 3.0/SRO 3.2)
Examinee: ___________________ NRC Examiner: ___________________
Facility Evaluator: ___________________ Date: _________
Method of Testing:
Simulated Performance Actual Performance X Classroom _________ Simulator X Plant _________
Read to the Examinee:
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.
Initial Conditions:
- 1. The Reactor is at 90% power.
Task Standard: The A Recirculation Pump has been tripped. The A Recirculation Pump suction valve has been closed and Electricians have been notified to close the A Recirculation Pump discharge valve IAW ABN-2.
Required Materials: None General
References:
ABN-2, Recirculation System Failures, Rev. 6 Initiating Cue: Power oscillations have been observed and attributed to fluctuations in reactor recirculation flow. Complete the applicable section of ABN-2, Recirculation System Failures.
Time Critical Task: No Validation Time: 21 minutes NRC Sim1 Rev. 01 Page 1 of 9
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Simulator Setup:
- 1. IC65
- 2. Reduce power to approximately 90% with recirc. flow
- 3. Fail Recirc. Pump A discharge valve OPEN: VLV-NSS006 to MECH SIEZE
- 4. Recirc. Pump A flow oscillations: MAL-RFC005A to 100%
- 5. Place the recirc. controller in V NRC Sim1 Rev. 01 Page 2 of 9
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________
Standard: Provides repeat back of initiating cue. Evaluator acknowledges repeat back.
Comment:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Performance Step: 2 Standard: Recognizes flow/speed fluctuations on the A Recirculation Pump (Panel 3F).
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim1 Rev. 01 Page 3 of 9
Appendix C Form ES-C-1 Performance Information Performance Step: 3 (step 3.3.2.A)
Standard: At Panel 3F, depresses the AUTO/MAN pushbutton to transfer A Recirculation Pump speed control to MANUAL.
NOTE: speed control is NOT regained.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 4 (step 3.3.2.D.1)
Standard: Determines APRM oscillations are > 4.6% (Panel 4F) and generator load fluctuations are > 30 MWe (Panel 8F/9F).
At Panel 3F, places the A Recirculation Pump Drive Motor Control switch to STOP.
FLOOR CUE: APRM fluctuations are 5% peak to peak AND generator load fluctuations are 40 MWe peak to peak (if not physically present).
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 5 (step 3.3.2.D.2)
Standard: Refers to Step 3.1.2 of ABN-2 for a single recirculation pump trip when five loops were operating.
Comment:
NRC Sim1 Rev. 01 Page 4 of 9
Appendix C Form ES-C-1
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim1 Rev. 01 Page 5 of 9
Appendix C Form ES-C-1 Performance Information Performance Step: 6 (step 3.1.2.A)
Standard: At Panel 3F, confirms A Recirc. Pump discharge bypass valve is open (red light ON; green light OFF).
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 7 (step 3.1.2.B)
Standard: At Panel 3F, places A Recirculation Pump discharge valve control switch to CLOSE. Notifies SRO of valve failure.
NOTE: The A Recirculation Pump discharge valve will not close.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 8 (step 3.1.2.D.1)
Standard: At Panel 3F, places A Recirculation Pump suction valve control switch to CLOSE (red light OFF; green light ON).
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim1 Rev. 01 Page 6 of 9
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 9 (step 3.1.2.D.2)
Standard: Refers to Attachment ABN-2-1; directs electrician to MCC 1A21A to close Recirc. Pump A discharge valve NG03A.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Terminating Cue: The A Recirculation Pump has been tripped. The A Recirculation Pump suction valve has been closed and Electricians have been notified to close the A Recirculation Pump discharge valve IAW ABN-2.
JPM Stop Time: ____________
NRC Sim1 Rev. 01 Page 7 of 9
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Sim1 Examinees Name: __________________
Examiners Name: __________________
Date Performed: __________________
Facility Evaluator: __________________
Number of Attempts: __________________
Time to Complete: __________________
Question:
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Response
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________
NRC Sim1 Rev. 01 Page 8 of 9
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions:
- 1. The Reactor is at 90% power.
Task Cue:
Power oscillations have been observed and attributed to fluctuations in reactor recirculation flow. Complete the applicable section of ABN-2, Recirculation System Failures.
NRC Sim1 Rev. 01 Page 9 of 9
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2040101412 Task Title: Place a Second RWCU Pump in Service Job Performance Measure No: NRC Sim2 (RO/SRO)
K/A
Reference:
204000 A4.01 (RO 3.1/SRO 3.0)
Examinee: ___________________ NRC Examiner: ___________________
Facility Evaluator: ___________________ Date: _________
Method of Testing:
Simulated Performance Actual Performance X Classroom _________ Simulator X Plant _________
Read to the Examinee:
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.
Initial Conditions:
- 1. The Reactor is at 95% power.
- 2. Reactor water level, power, and pressure are constant.
- 3. Reactor Water Cleanup Recirculation Pump A is in service with filter ND05A.
- 4. Chemistry samples show sulfates are out-of-spec high requiring two RWCU pump operation.
- 5. RBCCW is valved-in to the B Cleanup Recirculation Pump.
- 6. An Equipment Operator is in the field and has been briefed on the evolution and has a copy of the procedure.
Task Standard: The second Cleanup Recirculation Pump is in service with system flow approximately 700 gpm.
Required Materials: None NRC Sim2 Page 1 of 10
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET General
References:
Procedure 303, Reactor Cleanup Demineralizer System, Rev. 95 Initiating Cue: Place a second reactor water cleanup pump in service IAW Procedure 303, Section 22.0, and establish approximately 700 GPM system flow.
Step 22.3.1 has already been performed. When the second Cleanup Recirculation Pump is in service, another Operator will complete steps 22.3.14 through 22.3.17.
Time Critical Task: No Validation Time: 27 minutes Simulator Setup:
- 1. IC-65, with power reduced to 95% power, with recirculation flow.
- 2. Cleanup Pump A is in service.
- 3. LOA-RCU022 (for valve V-16-36 Pump A min. flow) and LOA-RCU023 (for valve V-16-37 Pump B moin. flow valve) to 1 to open the cleanup pumps min. flow valves.
- 4. LOA-RCU022 and LOA-RCU023 to 0 to close the cleanup pumps min. flow valves.
- 5. Adjust (raise) RBCCW to the NHRX HX (on drawing RBC02, change RBCCW flow through the NRHX to about 0.6 valve opening, when given the BOOTH CUE)
NRC Sim2 Page 2 of 10
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________
Standard: Provides repeat back of initiating cue. Evaluator acknowledges repeat back.
Comment:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Performance Step: 2 Standard: Verifies Prerequisites; Review Precautions and Limitations.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 3 (step 22.3.2)
Standard: Places placards on Panel 3F for heat balance adjustment and on Letdown Flow Controller to not exceed 760 GPM flow.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim2 Page 3 of 10
Appendix C Form ES-C-1 NRC Sim2 Page 4 of 10
Appendix C Form ES-C-1 Performance Information Performance Step: 4 (step 22.3.3)
Standard: Confirms B cleanup pump discharge valve (V-16-50) is closed (red light OFF; green light ON).
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 5 (step 22.3.4)
Standard: Directs equipment operator to open minimum flow valves V-16-36 & V-16-37 (using the local toggle switches).
NOTE: Activate LOA-RCU022 and LOA-RCU023 to 1 (OPEN). (Monitor and adjust RBCCW flow to CU system as required on screen RBC02 to about 0.6 RBCCW flow through the NRHX.)
BOOTH CUE: As the EO, report that both minimum flow valves V-16-36 and V-16-37 are open.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim2 Page 5 of 10
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 6 (step 22.3.5)
Standard: Makes plant announcement for the pump start (not required for critical task).
At Panel 3F, places the B Cleanup Recirculation Pump control switch to START (red light ON; green light OFF)
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 7 (22.3.6)
Standard: Slowly opens B Cleanup Recirculation Pump discharge valve V-16-50 until a small increase in pump discharge pressure is noted on Panel 3F. To throttle this valve, place the valve to OPEN, then to the neutral position to hold the valve in place.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 8 (step 22.3.7)
Standard: Slowly opens FCV-ND-16 to maintain original pump discharge pressure.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim2 Page 6 of 10
Appendix C Form ES-C-1 Performance Information Performance Step: 9 (step 22.3.8)
Standard: Adjusts PCV-ND11 to maintain system pressure at approximately 90 psig.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 10 (step 22.3.9/22.3.10)
Standard: Directs Equipment Operator to monitor:
- Demineralizer strainer dP
- Demineralizer dP
- Filter dP FLOOR CUE: As the Field Equipment Operator, Report:
- Demineralizer strainer dP is 7 psid
- Demineralizer dP is 8 psid
- Filter dP is 18 psid Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 11 (step 22.3.11)
Standard: Continues to open the pump discharge valve while adjusting pressure and flow, until the discharge valve is full open (red light ON; green light OFF).
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim2 Page 7 of 10
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 12 (step 22.3.12)
Standard: Increases flow with FCV ND-16 until flow is approximately 700 gpm, but does not exceed 760 gpm.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 13 (step 22.3.13)
Standard: When flow exceeds 500 gpm, directs Equipment Operator to close minimum flow valves V-16-36 & V-16-37 using the local toggle switches.
NOTE: Activate LOA-RCU022 and LOA-RCU023 to 0 (CLOSED). (Monitor and adjust RBCCW flow to CU system as required.)
BOOTH CUE: As the EO, report that both minimum flow valves V-16-36 and V-16-37 are closed.
FLOOR CUE: The candidate may request non-regeneration temperature: Report 95° F.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Terminating Cue: The second Cleanup Recirculation Pump is in service with system flow approximately 700 gpm.
JPM Stop Time: ____________
NRC Sim2 Page 8 of 10
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Sim2 Examinees Name: __________________
Examiners Name: __________________
Date Performed: __________________
Facility Evaluator: __________________
Number of Attempts: __________________
Time to Complete: __________________
Question:
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Response
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________
NRC Sim2 Page 9 of 10
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions:
- 1. The Reactor is at 95% power.
- 2. Reactor water level, power, and pressure are constant.
- 3. Reactor Water Cleanup Recirculation Pump A is in service with filter ND05A.
- 4. Chemistry samples show sulfates are out-of-spec high requiring two RWCU pump operation.
- 5. RBCCW is valved-in to the B Cleanup Recirculation Pump.
- 6. An Equipment Operator is in the field and has been briefed on the evolution and has a copy of the procedure.
Task Cue:
Place a second reactor water cleanup pump in service IAW Procedure 303, Section 22.0, and establish approximately 700 GPM system flow. Step 22.3.1 has already been performed. When the second Cleanup Recirculation Pump is in service, another Operator will complete steps 22.3.14 through 22.3.17.
NRC Sim2 Page 10 of 10
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2090101005 Task Title: Shutdown Core Spray After Inadvertent Initiation (Alternate Path)
Job Performance Measure No: NRC Sim3 (RO/SRO)
K/A
Reference:
209001 A4.01 (RO 3.8/SRO 3.6)
Examinee: ___________________ NRC Examiner: ___________________
Facility Evaluator: ___________________ Date: _________
Method of Testing:
Simulated Performance Actual Performance X Classroom _________ Simulator X Plant _________
Read to the Examinee:
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.
Initial Conditions:
- 1. The Reactor is at 100% power.
- 2. Reactor water level, power, and pressure are in the normal bands and are constant.
- 3. Low-Low Reactor Water Level Instrument RE02A has failed downscale.
- 4. Core Spray Systems 1 and 2 have initiated.
- 5. All other systems are operating properly.
- 6. The US has determined that adequate core cooling is assured.
Task Standard: Core Spray System I has been shutdown following automatic initiation.
Required Materials: None General
References:
Procedure 308, Emergency Core Cooling System Operation, Rev.
76 NRC Sim3 Page 1 of 8
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Initiating Cue: Secure Core Spray System 1 IAW Procedure 308, Section 5.0. Another Operator will secure Core Spray System 2.
Time Critical Task: No Validation Time: 20 minutes Simulator Setup:
- 1. IC-65
- 2. Fail RPV water level transmitter RE02A low (MAL-NSS007H to 85)
- 3. Fail control switch for Core Spray Booster Pump NZ03A in START (BKR-CSS001 to MECH SIEZE AFTER the core spray system is running)
- 4. To trip the Core Spray Booster Bump NZ03A breaker locally: BKR-CSS001 to TRIP NRC Sim3 Page 2 of 8
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________
Standard: Provides repeat back of initiating cue. Evaluator acknowledges repeat back.
Comment:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Performance Step: 2 Standard: Verify Prerequisites; Review Precautions and Limitations.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim3 Page 3 of 8
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 4 (step 5.3.2.1)
Standard: Overrides start logic for Core Spray Systems 1 and 2 by depressing RE02A OVERRIDE pushbutton located on the logic mimic on Panel 1F/2F. Observes amber OVERRIDE light is lit and the CH A ACTUATED light extinguishes.
Resets Core Spray start logic by depressing all ACTUATED pushbuttons located on the logic mimic on Panel 1F/2F.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 5 (step 5.3.3)
Standard: At Panel 1F/2F, confirms Core Spray System I Parallel Isolation Valves V-20-15 and V-20-40 are closed by observing green CLOSED indicating lights illuminated and red OPEN indicating lights extinguished.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim3 Page 4 of 8
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 6 (step 5.3.4)
NOTE: Core Spray System 1 Booster Pump NZ03A does not trip remotely.
Standard: At Panel 1F/2F, secures Core Spray System 1 Booster Pump NZ03A by placing its control switch to the STOP position. Observes the pump remains running based on no change in pump indications (red light ON; green light OFF; and discharge pressure unchanged)
Directs the Equipment Operator to trip Core Spray Booster Pump NZ03A by opening its breaker at USS 1A2 located in the 480V Room.
BOOTH CUE: As EO, acknowledge order to trip Core Spray Booster Pump NZ03A.
Input BKR-CSS001 to TRIP, and then report the breaker is tripped for Core Spray Booster Pump NZ03A.
Standard: Determines pump is tripped by observing pump status lights (red light OFF, green light ON) and pump discharge pressure and amps decrease.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 7 (step 5.3.5)
Standard: At Panel 1F/2F, secures Core Spray System 1 Main Pump NZ01A by placing its control switch to the STOP position. (red light OFF; green light ON; lowering pump discharge pressure and amps).
Comment:
NRC Sim3 Page 5 of 8
Appendix C Form ES-C-1
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Information Performance Step: 8 (step 5.3.6/5.3.7)
Standard: Confirms the System is filled and vented.
Verify Core Spray System 1 is in Standby Readiness.
FLOOR CUE: Another Operator will verify the Core Spray System I is filled and vented, and that the Core Spray System I is in Standby Readiness.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Terminating Cue: Core Spray System I has been shutdown following automatic initiation.
JPM Stop Time: ____________
NRC Sim3 Page 6 of 8
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Sim3 Examinees Name: __________________
Examiners Name: __________________
Date Performed: __________________
Facility Evaluator: __________________
Number of Attempts: __________________
Time to Complete: __________________
Question:
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Response
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________
NRC Sim3 Page 7 of 8
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions:
- 1. The Reactor is at 100% power.
- 2. Reactor water level, power, and pressure are in the normal bands and are constant.
- 3. Low-Low Reactor Water Level Instrument RE02A has failed downscale.
- 4. Core Spray Systems 1 and 2 have initiated.
- 5. All other systems are operating properly.
- 6. The US has determined that adequate core cooling is assured.
Task Cue:
Secure Core Spray System 1 IAW Procedure 308, Section 5.0. Another Operator will secure Core Spray System 2.
NRC Sim3 Page 8 of 8
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2120501402 Task Title: Bypass RPS Scram Logic Trips Job Performance Measure No: NRC Sim4 (RO/SRO)
K/A
Reference:
295037 EA1.01 (RO 4.6/SRO 4.6)
Examinee: ___________________ NRC Examiner: ___________________
Facility Evaluator: ___________________ Date: _________
Method of Testing:
Simulated Performance Actual Performance X Classroom _________ Simulator X Plant _________
Read to the Examinee:
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.
Initial Conditions:
- 1. The reactor was manually scrammed while at power.
- 2. A partial failure to scram has occurred.
Task Standard: The RPS trips have been bypassed, a manual scram inserted, and all control rods are fully inserted.
Required Materials: 4 EOP Bypass Plugs General
References:
- 2. Support Procedure 21, Alternate Insertion of Control Rods, Rev. 14 Initiating Cue: Reset the scram and manually scram the reactor, IAW Support Procedure 21.
Time Critical Task: No NRC Sim4 Page 1 of 9
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Validation Time: 15 minutes Simulator Setup:
- 1. IC-65
- 2. Insert hydraulic lock on control rods (partial): MAL-CRD021A at 100%
- 3. Manually scram the reactor
- 4. Manually initiate ARI
- 4. Following the scram, place Mode switch in Shutdown
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________
Standard: Provide repeat back of initiating cue. Evaluator acknowledges repeat back.
Comment:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Performance Step: 2 (step 3.2 of Support Procedure 21)
Standard: Identifies a hydraulic ATWS (Group scram solenoids are DE-ENERGIZED; individual scram lights for each control rod is ON)
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 3 (step 5.1.1)
Standard: At Panel 4F, starts the standby CRD pump by placing its control switch to START (red light ON; green light OFF).
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim4 Page 3 of 9
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 4 (step 5.1.2)
Standard: Bypasses ARI by placing the ARI Normal/Bypass Switch in the BYPASS position in the rear of Panel 8R.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 5 (step 5.1.3)
Standard: Resets ARI by depressing the ARI Manual reset pushbutton on Panel 4F.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 6 (step 5.1.4)
Standard: 1) Obtains four (4) bypass plugs from the EOP toolbox.
- 2) Opens EOP BYPASS PLUGS panel in the rear of Panel 6R.
- Inserts a bypass plug in position BP5.
- Inserts a bypass plug in position BP6.
- 3) Opens EOP BYPASS PLUGS panel in the rear of Panel 7R.
- Inserts a bypass plug in position BP5.
- Inserts a bypass plug in position BP6.
Comment:
NRC Sim4 Page 4 of 9
Appendix C Form ES-C-1
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim4 Page 5 of 9
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 7 (step 5.1.5)
Standard: At Panel 4F, places the SDV HI LVL BYPASS switch to the BYPASS position.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 8 (step 5.1.6)
Standard: Resets the scram by depressing the Scram Reset pushbutton on Panel 4F.
SIM BOOTH NOTE: Delete the hydraulic fail-to-scram after the scram is reset.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 9 (step 5.1.7)
Standard: At Panel 4F, confirms the SDV vent and drain valves indicate open.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim4 Page 6 of 9
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 10 Standard: When the SDV LEVEL HI-HI alarms clear (H-1-b/H-2-b), depresses both manual scram pushbuttons at Panel 4F. Verifies all control rods inserted and notifies SRO of all control rods inserted (not required for critical task).
NOTE: All control rods will insert.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Terminating Cue: The RPS trips have been bypassed, a manual scram inserted, and all control rods are fully inserted.
JPM Stop Time: ____________
NRC Sim4 Page 7 of 9
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Sim4 Examinees Name: __________________
Examiners Name: __________________
Date Performed: __________________
Facility Evaluator: __________________
Number of Attempts: __________________
Time to Complete: __________________
Question:
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Response
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________
NRC Sim4 Page 8 of 9
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions:
- 1. The reactor was manually scrammed while at power.
- 2. A partial failure to scram has occurred.
Task Cue:
Reset the scram and manually scram the reactor, IAW Support Procedure 21.
NRC Sim4 Page 9 of 9
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2000501435 Task Title: Prepare the Torus for Venting for Pressure Control Job Performance Measure No: NRC Sim5 (RO/SRO)
K/A
Reference:
295024 EA1.19 (RO 3.3/SRO 3.4)
Examinee: ___________________ NRC Examiner: ___________________
Facility Evaluator: ___________________ Date: _________
Method of Testing:
Simulated Performance Actual Performance X Classroom _________ Simulator X Plant _________
Read to the Examinee:
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.
Initial Conditions:
- 1. The reactor scrammed due to a LOCA.
- 2. The mode switch is in SHUTDOWN.
- 3. For the purpose of this JPM, Drywell pressure is 28 psig.
- 4. Torus venting has been directed by the EOPs.
Task Standard: Preparations for venting the Torus are complete IAW Section 2.0 of Support Procedure 32.
Required Materials: 1 EOP Bypass Plug General
References:
- 1. EMG-3200-02, Primary Containment Control, Rev. 17
- 2. Support Procedure 32, Venting the Torus for Primary Containment High Pressure, Rev. 17 NRC Sim5 Rev. 01 Page 1 of 10
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Initiating Cue: Prepare the torus for venting due to high Primary Containment pressure IAW Support Procedure 32, Section 2.0.
Time Critical Task: No Validation Time: 20 minutes Simulator Setup:
- 1. IC-65 2 Even though DW pressure of 28 psig will be simulated in this JPM, it is still necessary to have DW pressure above 3 psig to auto start SGTS (MAL-NSS005D to 1%)
- 3. Place Mode switch in Shutdown NRC Sim5 Rev. 01 Page 2 of 10
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________
Standard: Provide repeat back of initiating cue. Evaluator acknowledges repeat back.
Comment:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Performance Step: 2 (step 2.1)
Standard: At Panel 1F/2F, verifies Torus water level is below 348 inches.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim5 Rev. 01 Page 3 of 10
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 3 (step 2.2)
Standard: Evacuates the Reactor Building by performing the following:
- Sounds the Reactor Building Evacuation Alarm by placing the switch to REACTOR BLDG EVAC.
- Announces: "Primary containment venting will commence in approximately 5 minutes. All personnel evacuate the Reactor Building immediately. Stand clear of the stack and the Reactor Building fan pad" on the PAGING phone.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 4 (step 2.3)
Standard: Selects a SGTS train at Panel 11R and places its control switch in the HAND position (exhaust fan starts: red light ON, green light OFF; fan inlet and outlet valves open: red light ON, green light OFF; orifice valve closes: green light ON, red light OFF)
NOTE: One SGTS train should already be running. The candidate may select the SGTS train that is already running, but still must place the control switch for that train in HAND.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim5 Rev. 01 Page 4 of 10
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 5 (step 2.4)
Standard: Closes SGTS Crosstie at Panel 11R placing the SGTS crosstie valve V-28-48 in the CLOSED position (green light ON; red light OFF).
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 6 (step 2.5)
Standard: Confirms RB Supply Fans secured at Panel 11R (RB Supply Fans Off: green light ON, red light OFF)
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 7 (step 2.6)
Standard: Confirm RB Exhaust Fans secured at Panel 11R (RB Exhaust Fans Off: green light ON, red light OFF)
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim5 Rev. 01 Page 5 of 10
Appendix C Form ES-C-1 Performance Information Performance Step: 8 (step 2.7)
Standard: At Panel 4F, verifies the Mode Switch is NOT in RUN.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 9 (step 2.8)
Standard: Obtains one (1) bypass plug from the EOP toolbox in the Control Room.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 10 (step 2.9.1)
Standard: Opens EOP BYPASS PLUGS panel at the rear of Panel 10XF, and inserts bypass plug into position BP5.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim5 Rev. 01 Page 6 of 10
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 11 (step 2.10)
Standard: Opens EOP BYPASS PLUGS panel at the rear of Panel 11R, removes bypass plug from position BP4 and inserts bypass plug into position BP1.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 12 (step 2.11)
Standard: At Panel 11F, places the TORUS/ DRYWELL ISOLATION VALVE BYPASS PERMISSIVE keylock switch in the TORUS position.
NOTE: This switch is not labeled, but does have the following annotation above the keylock switch: Ensure Air Sample Taken Before Purging Drywell or Torus.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 13 (step 2.12)
Standard: At Panel 11F, places the TORUS/DW VENT AND PURGE ISOL VLVS HI RAD BYP keylock switches for Channels 1 and 2 in the BYPASS position.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim5 Rev. 01 Page 7 of 10
Appendix C Form ES-C-1 Performance Information Performance Step: 14 (step 2.13)
Standard: Reports to the SRO that the Torus venting preparations are complete.
FLOOR CUE: Acknowledge the report.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Terminating Cue: Preparations for venting the Torus are complete IAW Section 2.0 of Support Procedure 32.
JPM Stop Time: ____________
NRC Sim5 Rev. 01 Page 8 of 10
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Sim5 Examinees Name: __________________
Examiners Name: __________________
Date Performed: __________________
Facility Evaluator: __________________
Number of Attempts: __________________
Time to Complete: __________________
Question:
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Response
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________
NRC Sim5 Rev. 01 Page 9 of 10
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions:
- 1. The reactor scrammed due to a LOCA.
- 2. The mode switch is in SHUTDOWN.
- 3. For the purposes of this JPM, Drywell pressure is 28 psig.
- 4. Torus venting has been directed by the EOPs.
Task Cue:
Prepare the torus for venting due to high Primary Containment pressure IAW Support Procedure 32, Section 2.0.
NRC Sim5 Rev. 01 Page 10 of 10
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2640201003 Task Title: Perform the Emergency Diesel Generator Load Test (Alternate Path)
Job Performance Measure No: NRC Sim6 (RO/SRO)
K/A
Reference:
264000 A4.04 (RO 3.7/SRO 3.7)
Examinee: ___________________ NRC Examiner: ___________________
Facility Evaluator: ___________________ Date: _________
Method of Testing:
Simulated Performance Actual Performance X Classroom _________ Simulator X Plant _________
Read to the Examinee:
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.
Initial Conditions:
- 1. The Reactor is at 100% power, with all systems normally aligned.
- 2. All items listed in Prerequisite Section 3.0 of Procedure 636.4.003, Diesel Generator #1 Load Test, have been verified.
- 3. Steps 6.1 through 6.5 of Procedure 636.4.003 have been completed.
- 4. The System Dispatcher has been contacted and grid conditions are stable.
Task Standard: Following startup/loading of EDG1 for surveillance, EDG1 has been shutdown by the Candidate.
Required Materials: Prepared copy of procedure 636.4.003 (up through step 6.5).
General
References:
- 1. Procedure 636.4.003, Diesel Generator #1 Load test, Rev. 74 NRC Sim6 Page 1 of 10
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Initiating Cue: Beginning with step 6.6, perform Diesel Generator #1 Load Test IAW Procedure 636.4.003 for scheduled surveillance.
Time Critical Task: No Validation Time: 22 minutes Simulator Setup:
- 1. IC-65
- 2. Annunciator T3b, EDG1 ENG TEMP HI: ANN-T-6b to ON during the EDG run (step 12)
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________
Standard: Provide repeat back of initiating cue. Evaluator acknowledges repeat back.
Comment:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Performance Step: 2 Standard: Verifies Prerequisites, review Precautions and Limitations.
NOTE/FLOOR CUE: All prerequisites have been verified, as outlined in the Initial Conditions.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim6 Page 3 of 10
Appendix C Form ES-C-1 Performance Information Performance Step: 3 (step 6.6)
Standard: Confirms EDG lineup: At Panel 8F/9F:
- UNIT START and UNIT IDLE lights are extinguished
- All EDG 1 alarms in their normal state (no alarms)
- The EDG 1 MODE SELECTOR switch is in the PEAKING position Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 4 (step 6.7)
Standard: Verifies an Equipment Operator at EDG 1 prior to starting EDG 1.
BOOTH CUE: As the Equipment Operator, report that you are at EDG 1 standing-by.
NOTE: The next procedure step (step 6.8) is only a caution/note.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 5 (step 6.9)
Standard: To start the EDG At Panel 8F/9F, momentarily places EDG 1 NORMAL START switch to the START position.
NOTE: EDG will idle for approximately 90 seconds then accelerate to 900 RPM. EDG will then automatically synchronize, the breaker will close, and it will automatically achieve rated load (2750 KW).
NRC Sim6 Page 4 of 10
Appendix C Form ES-C-1 Performance Information Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 6 (step 6.10)
Standard: Verifies EDG start at Panel 8F/9F, by observing UNIT START and UNIT IDLING lights illuminate.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 7 (step 6.11)
Standard: Verifies proper creepy crank operation with the EO.
BOOTH CUE: As the Equipment Operator, report proper creepy crank operation.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 8 (step 6.12)
NRC Sim6 Page 5 of 10
Appendix C Form ES-C-1 Standard: Verifies EDG 1 automatically comes up to speed, automatically synchronizes with the line, EDG 1 load breaker closes (red light ON, green light OFF) and begins to pickup load (DG KW, KVAR, Amps rise on Panel 8F/9F)
Performance Information Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 9 (step 6.13)
Standard: Observes EDG load rises automatically to approximately 2750 KW and records the initial full load achieved (acceptable range is 2600-2800 KW).
FLOOR CUE: EDG1 KW loading indicates 2850 KW Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 10 (step 6.14.1 / 6.14.2)
Standard: 1) Places EDG 1 MODE SELECTOR switch to TRANSFER position.
- 2) Adjusts load to 2750 KW using the EDG1 GOVERNOR CONTROL switch to LOWER.
FLOOR CUE: (AFTER a small adjustment) EDG1 KW loading indicates 2700 KW Note: Procedure steps 6.15 and 6.16 are not applicable.
Comment:
NRC Sim6 Page 6 of 10
Appendix C Form ES-C-1
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Information Performance Step: 11 (step 6.17)
Standard: Records time that load level of 2600-2800 KW was attained.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 12 (step 6.18)
Standard: Adjusts KVAR load by adjusting the VOLTAGE/KVAR CONTROL switch to obtain approximately +1000 KVAR (lagging) (acceptable range is +200 to
+2000 KVAR lagging).
NOTE: KVAR load should be within the acceptable range of +200 to +2000. The Candidate may/may not adjust from within this range to attain +1000 KVAR.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
9 Performance Step: 13 NOTE: Input ANN-T-6-b, EDG1 ENG TEMP HI, at this time.
NRC Sim6 Page 7 of 10
Appendix C Form ES-C-1 Standard: Responds to annunciator T6b: EDG1 ENG TEMP HI
- 1) May direct the Equipment Operator to verify proper louver operation.
- 2) Trips the EDG by placing the NORMAL START switch to the STOP position (KW, KVAR, amps lower; EDG1 breaker opens [red light OFF, green light ON]).
BOOTH CUE: (As the Equipment Operator) The EDG1 louvers are full open.
Performance Information Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Terminating Cue: Following startup/loading of EDG1 for surveillance, EDG1 has been shutdown by the Candidate.
JPM Stop Time: ____________
NRC Sim6 Page 8 of 10
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Sim6 Examinees Name: __________________
Examiners Name: __________________
Date Performed: __________________
Facility Evaluator: __________________
Number of Attempts: __________________
Time to Complete: __________________
Question:
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Response
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________
NRC Sim6 Page 9 of 10
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions:
- 1. The Reactor is at 100% power, all systems normally aligned.
- 2. All items listed in Prerequisite Section 3.0 of Procedure 636.4.003, Diesel Generator #1 Load Test, have been verified.
- 3. Steps 6.1 through 6.5 of Procedure 636.4.003 have been completed.
- 4. The System Dispatcher has been contacted and grid conditions are stable.
Task Cue:
Beginning with step 6.6, perform Diesel Generator #1 Load Test IAW Procedure 636.4.003 for scheduled surveillance.
NRC Sim6 Page 10 of 10
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2180401001 Task Title: Perform EMRV Operability Test w/ Stuck Open EMRV (Alternate Path)
Job Performance Measure No: NRC Sim7 (RO/SRO)
K/A
Reference:
239002 A2.03 (RO 4.1/SRO 4.2)
Examinee: ___________________ NRC Examiner: ___________________
Facility Evaluator: ___________________ Date: _________
Method of Testing:
Simulated Performance Actual Performance X Classroom _________ Simulator X Plant _________
Read to the Examinee:
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.
Initial Conditions:
- 1. A reactor startup is in progress.
- 2. Reactor power is less that 5%.
- 3. Reactor water level, power, and pressure are constant.
- 4. RPV water level control is in manual, and will be controlled by another Operator.
- 5. EMRV Operability Testing is required for valve NR-108A only.
- 6. Procedure steps 6.1 through 6.24 of 602.4.003, Electromatic Relief Valve Operability Test, have been completed for EMRV NR-108A.
Task Standard: The EMRV has been closed when the NR-108A EMRV Normal/Disable keylock switch has been placed in DISABLE.
NRC Sim7 Page 1 of 9
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Required Materials:
- 1. Stopwatch
- 2. Prepared copy of 602.4.003 (completed up through step 6.24)
General
References:
- 1. 602.4.003, Electromatic Relief Valve Operability Test, Rev. 29
- 2. ABN-40, Stuck Open EMRV, Rev. 2 Initiating Cue: Complete procedure 602.4.003, Electromatic Relief Valve Operability Test for EMRV NR-108A, beginning at step 6.25.
Time Critical Task: No Validation Time: 23 minutes Simulator Setup:
- 1. Low power IC (about 5% power, but is not required)
- 2. FW Control in manual
- 3. Select EMRV NR018A for tail-piece indication on 1F/2F
- 4. EMRV 108A control switch stuck in the MAN position (open) AFTER the valve is opened: SWI-ADS001C to ON NRC Sim7 Page 2 of 9
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________
Standard: Provide repeat back of initiating cue. Evaluator acknowledges repeat back.
Comment:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Performance Step: 2 Standard: Reviews Precautions and Limitations.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim7 Page 3 of 9
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 3 (step 6.25)
FLOOR CUE: Tell the Candidate that you will record the valve stroke times for him.
Standard: At Panel 1F/2F, places the control switch for EMRV NR-108A in the MAN position and starts the stopwatch (red light ON; green light OFF).
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 4 (step 6.26)
Standard: When annunciator SV/EMRV NOT CLOSED (B-4-g) alarms, stop the stopwatch; records time on Attachment 602.4.003-1 (See CUE in Step 4).
At Panel 1F/2F, verifies:
- Red light is lit and green light is extinguished for EMRV NR-108A.
- Acoustic valve monitor is in the valve open region.
- Annunciator EMRV OPEN (B-3-g) is in alarm.
NOTE: After the EMRV is manually opened, insert malfunction SWI-ADS001C to ON (this prevents the valve from being manually closed).
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim7 Page 4 of 9
Appendix C Form ES-C-1 Performance Information Performance Step: 5 (step 6.27)
NOTE: The EMRV will NOT close at this time and remains open.
Standard: At Panel 1F/2F, 5 seconds after opening NR-108A, places its control switch in the AUTO position and starts the stopwatch.
Reports/recognizes EMRV will not close (red light ON, green light OFF; acoustic monitor still shows in the Valve Open Region (red); annunciators still in alarm), and enters ABN-40, Stuck Open EMRV.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 6 (step 3.1 of ABN-40)
Standard: Verifies EMRV open (by any of the following): red light ON, acoustic monitor shows valve open (red region), EMRV discharge temperature high.
CUE: If requested to verify EMRV tailpiece temperature on RB 23, report the temperature is about 320° F.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim7 Page 5 of 9
Appendix C Form ES-C-1 Performance Information Performance Step: 7 (step 3.2)
Standard: Verifies Feedwater Control in Manual CUE: Another Operator has confirmed Manual Control on the Master Controller and will be controlling feedwater.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 8 (step 3.2.3/3.2.4)
Standard: At Panel 1F/2F, places EMRV NR-108A control switch in the OFF position; recognizes EMRV is still open (acoustic monitor still in the RED area; valve red light still ON; annunciators still lit; tailpiece temperature still high).
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 9 (step 3.2.5/3.2.6)
Standard: At Panel 1F/2F, cycles EMRV NR-108A control switch from OFF to MAN to OFF another 3-5 times in an attempt to close the EMRV; recognizes EMRV is still open (acoustic monitor still in the RED area; valve red light still ON; annunciators still lit; tailpiece temperature still high).
Comment:
NRC Sim7 Page 6 of 9
Appendix C Form ES-C-1
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Information 9 Performance Step: 10 (step 3.2.7)
NOTE: When the Normal/Disable keylock switch is placed in DISABLE, red/green position indication lights for the valve are lost on Panel 1F/2F.
Standard: In the rear of Panel 1F/2F, places NR-108A EMRV Normal/Disable keylock switch in DISABLE. Verifies EMRV closes (acoustic monitor in the Valve Closed Region (white); tailpiece temperature lowering).
Reports that the EMRV is closed (not required for critical task).
FLOOR CUE: Acknowledge the report.
Note: This action will close the EMRV.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Terminating Cue: The EMRV has been closed when the NR-108A EMRV Normal/Disable keylock switch has been placed in DISABLE.
JPM Stop Time: ____________
NRC Sim7 Page 7 of 9
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Sim7 Examinees Name: __________________
Examiners Name: __________________
Date Performed: __________________
Facility Evaluator: __________________
Number of Attempts: __________________
Time to Complete: __________________
Question:
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Response
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________
NRC Sim7 Page 8 of 9
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions:
- 1. A reactor startup is in progress.
- 2. Reactor power is less that 5%.
- 3. Reactor water level, power, and pressure are constant.
- 4. RPV water level control is in manual, and will be controlled by another Operator.
- 5. EMRV Operability Testing is required for valve NR-108A only.
- 6. Procedure steps 6.1 through 6.24 of 602.4.003, Electromatic Relief Valve Operability Test, have been completed for EMRV NR-108A.
Task Cue:
Complete procedure 602.4.003, Electromatic Relief Valve Operability Test for EMRV NR-108A, beginning at step 6.25.
NRC Sim7 Page 9 of 9
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Facility: Oyster Creek Task No: 2180401001 Task Title: Perform EMRV Operability Test w/ Stuck Open EMRV (Alternate Path)
Job Performance Measure No: NRC Sim7 (RO/SRO)
K/A
Reference:
239002 A2.03 (RO 4.1/SRO 4.2)
Examinee: ___________________ NRC Examiner: ___________________
Facility Evaluator: ___________________ Date: _________
Method of Testing:
Simulated Performance Actual Performance X Classroom _________ Simulator X Plant _________
Read to the Examinee:
I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.
Initial Conditions:
- 1. A reactor startup is in progress.
- 2. Reactor power is less that 5%.
- 3. Reactor water level, power, and pressure are constant.
- 4. RPV water level control is in manual, and will be controlled by another Operator.
- 5. EMRV Operability Testing is required for valve NR-108A only.
- 6. Procedure steps 6.1 through 6.24 of 602.4.003, Electromatic Relief Valve Operability Test, have been completed for EMRV NR-108A.
Task Standard: The EMRV has been closed when the NR-108A EMRV Normal/Disable keylock switch has been placed in DISABLE.
NRC Sim7 Page 1 of 9
Appendix C Job Performance Measure Form ES-C-1 WORKSHEET Required Materials:
- 1. Stopwatch
- 2. Prepared copy of 602.4.003 (completed up through step 6.24)
General
References:
- 1. 602.4.003, Electromatic Relief Valve Operability Test, Rev. 29
- 2. ABN-40, Stuck Open EMRV, Rev. 2 Initiating Cue: Complete procedure 602.4.003, Electromatic Relief Valve Operability Test for EMRV NR-108A, beginning at step 6.25.
Time Critical Task: No Validation Time: 23 minutes Simulator Setup:
- 1. Low power IC (about 5% power, but is not required)
- 2. FW Control in manual
- 3. Select EMRV NR018A for tail-piece indication on 1F/2F
- 4. EMRV 108A control switch stuck in the MAN position (open) AFTER the valve is opened: SWI-ADS001C to ON NRC Sim7 Page 2 of 9
Appendix C Form ES-C-1 Performance Information Denote critical steps with a check mark Performance Step: 1 JPM Start Time: ____________
Standard: Provide repeat back of initiating cue. Evaluator acknowledges repeat back.
Comment:
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
Performance Step: 2 Standard: Reviews Precautions and Limitations.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim7 Page 3 of 9
Appendix C Form ES-C-1 Performance Information 9 Performance Step: 3 (step 6.25)
FLOOR CUE: Tell the Candidate that you will record the valve stroke times for him.
Standard: At Panel 1F/2F, places the control switch for EMRV NR-108A in the MAN position and starts the stopwatch (red light ON; green light OFF).
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 4 (step 6.26)
Standard: When annunciator SV/EMRV NOT CLOSED (B-4-g) alarms, stop the stopwatch; records time on Attachment 602.4.003-1 (See CUE in Step 4).
At Panel 1F/2F, verifies:
- Red light is lit and green light is extinguished for EMRV NR-108A.
- Acoustic valve monitor is in the valve open region.
- Annunciator EMRV OPEN (B-3-g) is in alarm.
NOTE: After the EMRV is manually opened, insert malfunction SWI-ADS001C to ON (this prevents the valve from being manually closed).
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim7 Page 4 of 9
Appendix C Form ES-C-1 Performance Information Performance Step: 5 (step 6.27)
NOTE: The EMRV will NOT close at this time and remains open.
Standard: At Panel 1F/2F, 5 seconds after opening NR-108A, places its control switch in the AUTO position and starts the stopwatch.
Reports/recognizes EMRV will not close (red light ON, green light OFF; acoustic monitor still shows in the Valve Open Region (red); annunciators still in alarm), and enters ABN-40, Stuck Open EMRV.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 6 (step 3.1 of ABN-40)
Standard: Verifies EMRV open (by any of the following): red light ON, acoustic monitor shows valve open (red region), EMRV discharge temperature high.
CUE: If requested to verify EMRV tailpiece temperature on RB 23, report the temperature is about 320° F.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
NRC Sim7 Page 5 of 9
Appendix C Form ES-C-1 Performance Information Performance Step: 7 (step 3.2)
Standard: Verifies Feedwater Control in Manual CUE: Another Operator has confirmed Manual Control on the Master Controller and will be controlling feedwater.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 8 (step 3.2.3/3.2.4)
Standard: At Panel 1F/2F, places EMRV NR-108A control switch in the OFF position; recognizes EMRV is still open (acoustic monitor still in the RED area; valve red light still ON; annunciators still lit; tailpiece temperature still high).
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Step: 9 (step 3.2.5/3.2.6)
Standard: At Panel 1F/2F, cycles EMRV NR-108A control switch from OFF to MAN to OFF another 3-5 times in an attempt to close the EMRV; recognizes EMRV is still open (acoustic monitor still in the RED area; valve red light still ON; annunciators still lit; tailpiece temperature still high).
Comment:
NRC Sim7 Page 6 of 9
Appendix C Form ES-C-1
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Performance Information 9 Performance Step: 10 (step 3.2.7)
NOTE: When the Normal/Disable keylock switch is placed in DISABLE, red/green position indication lights for the valve are lost on Panel 1F/2F.
Standard: In the rear of Panel 1F/2F, places NR-108A EMRV Normal/Disable keylock switch in DISABLE. Verifies EMRV closes (acoustic monitor in the Valve Closed Region (white); tailpiece temperature lowering).
Reports that the EMRV is closed (not required for critical task).
FLOOR CUE: Acknowledge the report.
Note: This action will close the EMRV.
Comment:
_________________________________________________________________________________
_________________________________________________________________________________
_________________________________________________________________________________
Terminating Cue: The EMRV has been closed when the NR-108A EMRV Normal/Disable keylock switch has been placed in DISABLE.
JPM Stop Time: ____________
NRC Sim7 Page 7 of 9
Appendix C Form ES-C-1 Validation of Completion Job Performance Measure No. NRC Sim7 Examinees Name: __________________
Examiners Name: __________________
Date Performed: __________________
Facility Evaluator: __________________
Number of Attempts: __________________
Time to Complete: __________________
Question:
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Response
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
Result: Satisfactory/Unsatisfactory Examiners signature and date: ____________________________ _____________
NRC Sim7 Page 8 of 9
Appendix C Form ES-C-1 STUDENT HANDOUT Initial Conditions:
- 1. A reactor startup is in progress.
- 2. Reactor power is less that 5%.
- 3. Reactor water level, power, and pressure are constant.
- 4. RPV water level control is in manual, and will be controlled by another Operator.
- 5. EMRV Operability Testing is required for valve NR-108A only.
- 6. Procedure steps 6.1 through 6.24 of 602.4.003, Electromatic Relief Valve Operability Test, have been completed for EMRV NR-108A.
Task Cue:
Complete procedure 602.4.003, Electromatic Relief Valve Operability Test for EMRV NR-108A, beginning at step 6.25.
NRC Sim7 Page 9 of 9