ML18162A026: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
(7 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML18162A026
| number = ML18162A026
| issue date = 06/12/2018
| issue date = 06/12/2018
| title = Prairie Island Nuclear Generating Plant, Units 1 and 2 - License Amendment Request to Reclassify Certain Fuel Handling Equipment
| title = License Amendment Request to Reclassify Certain Fuel Handling Equipment
| author name =  
| author name =  
| author affiliation = Northern States Power Co, Xcel Energy
| author affiliation = Northern States Power Co, Xcel Energy
Line 9: Line 9:
| docket = 05000282, 05000306
| docket = 05000282, 05000306
| license number = DPR-042, DPR-060
| license number = DPR-042, DPR-060
| contact person = Kuntz R F, 415-3733
| contact person = Kuntz R, 415-3733
| document type = Slides and Viewgraphs
| document type = Slides and Viewgraphs
| page count = 9
| page count = 9
| project =
| stage = Request
}}
}}


=Text=
=Text=
{{#Wiki_filter:Prairie Island License Amendment Request to Reclassify Certain Fuel Handling Equipment June 12 2018 Northern States Power  
{{#Wiki_filter:Prairie Island License Amendment Request to Reclassify Certain Fuel Handling Equipment June 12 2018 Northern States Power - Minnesota
- Minnesota


*License Amendment Request
Presentation Outline
*Background
* License Amendment Request
*Scope *Example *Additional Information
* Background
*Summary Presentation Outline
* Scope
* Example
* Additional Information
* Summary


*Approval of USAR changes that revise the PINGP Quality Group classification for certain fuel handling equipment from QA Type I (safety
-related) to QA Type III (commercial grade)
*Changes are consistent with industry standards
-ANSI/ANS 58.14
-1993 Section 5.6.1, Item 9 -ANSI/ANS 57.1
-1992, Section 6.3
*Purchasing safety
-related spare parts does not provide commensurate public health and safety benefits.
License Amendment Request
License Amendment Request
* Approval of USAR changes that revise the PINGP Quality Group classification for certain fuel handling equipment from QA Type I (safety-related) to QA Type III (commercial grade)
* Changes are consistent with industry standards
    - ANSI/ANS 58.14-1993 Section 5.6.1, Item 9
    - ANSI/ANS 57.1-1992, Section 6.3
* Purchasing safety-related spare parts does not provide commensurate public health and safety benefits.


*PINGP was designed and build in late 1960's/early 1970s
===
-Prior to issuance of GDCs
Background===
-Before guidance for classifying SSCs *Original A/E developed standard of 1% of 10 CFR 100 limits for classifying SSCs
* PINGP was designed and build in late 1960s/early 1970s
    - Prior to issuance of GDCs
    - Before guidance for classifying SSCs
* Original A/E developed standard of 1% of 10 CFR 100 limits for classifying SSCs


===Background===
===
Background===
* PINGP is approved for full scope AST
    - 10 CFR 50.67 replaces 10 CFR 100 as licensing basis
* Fuel handling accident offsite dose consequences fall below 10% of 10 CFR 50.67 limits.
* Fuel handling equipment is currently classified as QA-Type I (safety-related)


*PINGP is approved for full scope AST -10 CFR 50.67 replaces 10 CFR 100 as licensing basis
Scope Fuel Handling Equipment to be Reclassified as QA Type III:
*Fuel handling accident offsite dose consequences fall below 10% of 10 CFR 50.67 limits.
* Auxiliary Building Crane
*Fuel handling equipment is currently classified as QA-Type I (safety-related) Background
* Spent Fuel Pool Crane
* Manipulator Cranes, including Load Cells
* Spent Fuel Assembly Handling Tools
* Rod Cluster Control Changing Tools
* Spent Fuel Transfer System and its constituent components (conveyors, upenders, and related equipment), exclusive of transfer tubes and blind flanges


Fuel Handling Equipment to be Reclassified as "QA Type III":
Example Additional Information
  *Auxiliary Building Crane
* The QA classification of fuel handling equipment, including cranes, is not discussed in the NSPM QA Manual
*Spent Fuel Pool Crane
* The scope of this amendment does not impact important to safety SSCs described in the PINGP ISFI USAR.
*Manipulator Cranes, including Load Cells
* Approval requested by September 1, 2019 to support 1R30
*Spent Fuel Assembly Handling Tools
* Precedence
*Rod Cluster Control Changing Tools
*Spent Fuel Transfer System and its constituent components (conveyors, upenders, and related equipment), exclusive of transfer tubes and blind flanges Scope Example
*The QA classification of fuel handling equipment, including cranes, is not discussed in the NSPM QA Manual
*The scope of this amendment does not impact "important to safety" SSCs described in the PINGP ISFI USAR.  
*Approval requested by September 1, 2019 to support 1R30
*Precedence Additional Information


*Proposed LAR will reclassify certain fuel handling equipment as QA Type  
Summary
- III (commercial grade
* Proposed LAR will reclassify certain fuel handling equipment as QA Type - III (commercial grade)
*Original PINGP classification scheme (1% of 10 CFR 100 limits) is more conservative than current standards
* Original PINGP classification scheme (1% of 10 CFR 100 limits) is more conservative than current standards
*PINGP was approved for full scope AST
* PINGP was approved for full scope AST
*Fuel handling accident consequences fall below 10% of 10 CFR 50.67 limits Summary}}
* Fuel handling accident consequences fall below 10% of 10 CFR 50.67 limits}}

Latest revision as of 23:36, 20 October 2019

License Amendment Request to Reclassify Certain Fuel Handling Equipment
ML18162A026
Person / Time
Site: Prairie Island  Xcel Energy icon.png
Issue date: 06/12/2018
From:
Northern States Power Co, Xcel Energy
To:
Plant Licensing Branch III
Kuntz R, 415-3733
References
Download: ML18162A026 (9)


Text

Prairie Island License Amendment Request to Reclassify Certain Fuel Handling Equipment June 12 2018 Northern States Power - Minnesota

Presentation Outline

  • License Amendment Request
  • Background
  • Scope
  • Example
  • Additional Information
  • Summary

License Amendment Request

  • Approval of USAR changes that revise the PINGP Quality Group classification for certain fuel handling equipment from QA Type I (safety-related) to QA Type III (commercial grade)
  • Changes are consistent with industry standards

- ANSI/ANS 58.14-1993 Section 5.6.1, Item 9

- ANSI/ANS 57.1-1992, Section 6.3

  • Purchasing safety-related spare parts does not provide commensurate public health and safety benefits.

=

Background===

  • PINGP was designed and build in late 1960s/early 1970s

- Prior to issuance of GDCs

- Before guidance for classifying SSCs

  • Original A/E developed standard of 1% of 10 CFR 100 limits for classifying SSCs

=

Background===

- 10 CFR 50.67 replaces 10 CFR 100 as licensing basis

  • Fuel handling accident offsite dose consequences fall below 10% of 10 CFR 50.67 limits.
  • Fuel handling equipment is currently classified as QA-Type I (safety-related)

Scope Fuel Handling Equipment to be Reclassified as QA Type III:

  • Auxiliary Building Crane
  • Spent Fuel Pool Crane
  • Manipulator Cranes, including Load Cells
  • Spent Fuel Assembly Handling Tools
  • Rod Cluster Control Changing Tools
  • Spent Fuel Transfer System and its constituent components (conveyors, upenders, and related equipment), exclusive of transfer tubes and blind flanges

Example Additional Information

  • The QA classification of fuel handling equipment, including cranes, is not discussed in the NSPM QA Manual
  • The scope of this amendment does not impact important to safety SSCs described in the PINGP ISFI USAR.
  • Approval requested by September 1, 2019 to support 1R30
  • Precedence

Summary

  • Original PINGP classification scheme (1% of 10 CFR 100 limits) is more conservative than current standards
  • Fuel handling accident consequences fall below 10% of 10 CFR 50.67 limits