{{#Wiki_filter:7/- 907/
RETURN TO A. MachEn FCTC: RHO                                                                  396-83 SEP 3 01985 71-9071 ANEFCO. Inc.
ATTN: Dr. John D. Murphy, Sr.
P.O. Box 433 Ridgefield, CT 06877 Gentlemen:
This refers to your application dated August 13, 1985, requesting approval of a supplementary shield for the flodel No. AP-101 cask.
1                    In connection with our review, we need an analysis denenstrating the proposed shield remains effective under norral and accident conditions of transport (10 CFR 5571.47 and 71.51(a)(2)). Your letter of August 13 was not responsive to our letter of July 12, 1985. The various drop orientations were not taken into account for nornal and accident conditions of transport. The supplemental shielding is directional in its effectiveness, this is an unacceptable practice. The shoring used to support the supplemental shielding has not been shown to damage the inner cavity walls under normal conditions of transport.
The additional information requested by this letter should be submitted in the form of a new application within 60 days from the date of this letter. If you have any questions regarding this ratter, we would be pleased to meet with you and your staff.
Sincerely,
                                                                          ,am ey i
htim/S E '#
                                                                . Charles E. MacDonald, Chief Distribution:                                Transportation Certification Branch RH0degaarden (2)                            Division of Fuel Cycle and HWLee                                          ftaterial Safety, HMSS CRMarotta NRC PDR IE HQ Region I Docket File            e510030110 PDR    ADOCK 0B fo9071 PDR l
NMSS R/F              C j                    FCTC R/F
                  ' fCTC bW
    " " ' '
* FCT          fCTC
  .--RW0degaarden: alm
                                                          ._ FCT[ k HWLee    CRMarotta    CEMa Monald
                                                                    '        ~'
      ==>      09hl[85                        0972E)85    09/f}/85 09/hd85 nac ronu ne no sai nncu o24o                OFFICIAL RECORD COPY
                                                                                                          ~!}}

Latest revision as of 18:42, 30 June 2020

Requests Addl Info Re 850813 Request for Approval of Supplementary Shield for Model AP-101.Analysis Demonstrating Proposed Shield Remains Effective Under Normal & Accident Conditions of Transport Needed
ML20137U368
Person / Time
Site: 07109071
Issue date: 09/30/1985
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Jerome Murphy
ANEFCO, INC.
References
NUDOCS 8510030110
Download: ML20137U368 (1)


Text

7/- 907/

RETURN TO A. MachEn FCTC: RHO 396-83 SEP 3 01985 71-9071 ANEFCO. Inc.

ATTN: Dr. John D. Murphy, Sr.

P.O. Box 433 Ridgefield, CT 06877 Gentlemen:

This refers to your application dated August 13, 1985, requesting approval of a supplementary shield for the flodel No. AP-101 cask.

1 In connection with our review, we need an analysis denenstrating the proposed shield remains effective under norral and accident conditions of transport (10 CFR 5571.47 and 71.51(a)(2)). Your letter of August 13 was not responsive to our letter of July 12, 1985. The various drop orientations were not taken into account for nornal and accident conditions of transport. The supplemental shielding is directional in its effectiveness, this is an unacceptable practice. The shoring used to support the supplemental shielding has not been shown to damage the inner cavity walls under normal conditions of transport.

The additional information requested by this letter should be submitted in the form of a new application within 60 days from the date of this letter. If you have any questions regarding this ratter, we would be pleased to meet with you and your staff.

Sincerely,

,am ey i

htim/S E '#

. Charles E. MacDonald, Chief Distribution: Transportation Certification Branch RH0degaarden (2) Division of Fuel Cycle and HWLee ftaterial Safety, HMSS CRMarotta NRC PDR IE HQ Region I Docket File e510030110 PDR ADOCK 0B fo9071 PDR l

NMSS R/F C j FCTC R/F

' fCTC bW

" " ' '

  • FCT fCTC

.--RW0degaarden: alm

._ FCT[ k HWLee CRMarotta CEMa Monald

' ~'

==> 09hl[85 0972E)85 09/f}/85 09/hd85 nac ronu ne no sai nncu o24o OFFICIAL RECORD COPY

~!