{{#Wiki_filter:CENG.a joint venture ofConstellation
~E~eDFEnergy* 0NINE MILE POINTNUCLEAR STATIONNovember 5, 2013U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 ATTENTION:
==SUBJECT:==
Document Control DeskNine Mile Point Nuclear StationRenewed Facility Operating License No. DPR-63Unit No. 1; Docket No. 50-220Core Operating Limits ReportEnclosed is a copy of the Core Operating Limits Report, COLR1-21, Revision 1 for Nine Mile Point Unit1 (NMP1). This report is being submitted pursuant to NMPI Technical Specification 6.6.5.d.
TheCOLR is being revised to provide a more robust description of Linear Heat Generation Rates (LHGR)values and their source documentation based on an internal Quality Assurance observation.
Should you have any questions regarding the information in this submittal, please contact Everett P.Perkins, Director
-Licensing, at (315) 349-5219.
Very truly yours,Paul M. SwiftManager, Engineering ServicesPMS/MHS
==Enclosure:==
Nine Mile Point Unit 1 Core Operating Limits ReportNine Mile Point Nuclear Station, LLCP.O. Box 63, Lycoming, NY 13093 Document Control DeskNovember 5, 2013Page 2cc: NRC Regional Administrator, Region INRC Project ManagerNRC Senior Resident Inspector ENCLOSURE Nine Mile Point Unit 1Core Operating Limits ReportNine Mile Point Nuclear Station, LLCNovember 5, 2013 NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTDocument No.:COLRI-21Revision 01NameTitleDatePrepared by:Reviewed by:Approved by:Approved by:Approved by:obert CloseJohn DarweeshPhil Wengloski Pi'sA' LFuelsEngineerFuelsEngineerSupervisor, Nuclear FuelServicesSupervisor, ReactorEngineering GeneralSupervisor, Nuclear FuelServices/0/.22/13
/0 Z//ziol4.111-This Controlled Document provides cycle specific core operating limits for use in conjunction with the Nine Mile Point Unit I Technical Specifications.
Document pages may only be changedthrough a reissue of the entire document.
COLRI-21 NINE MILE POINT UNIT I Revision 01CORE OPERATING LIMITS REPORTTERMS AND DEFINITIONS Averaqe Planar Linear Heat Generation Rate (APLHGR)The Average Planar Linear Heat Generation Rate (APLHGR) shall be applicable to a specific planarheight and is equal to the sum of the heat generation rate per unit length of fuel rod for all fuel rodsin the specified bundle at the specified height, divided by the number of fuel rods in the fuel bundleat that heightBOCBeginning of CycleMaxiumum Fraction of Limiting Power Density (MFLPD)The highest value of the fraction of limiting power density which exists in the coreEOREnd of Rated Conditions (i.e. cycle exposure at 100% power, 100% flow, all rods-out, all feedwater heaters in service and equilibrium xenon)MCPR flow dependent multiplier K(P)MCPR power dependent multiplier LHGRFAC(P)
Power dependent LHGR correction factorLinear Heat Generation Rate (LHGR)The heat generation per unit length of fuel rod. It is the integral of the heat flux over the heattransfer area associated with the fuel lengthMAPLHGRMaximum Average Planar Linear Heat Generation RateMinimum Critical Power Ratio (MCPR)The minimum in-core critical power ratioFBIRFuel Bundle Information ReportMDFWPMotor driven feedwater pumpTDFWPTurbine driven feedwater pumpPage i COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Table of Contents1.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)1.1 Limits for Technical Specification 3.1.7.a1.2 Limits for Technical Specification 3.1.7.e2.0 MINIMUM CRITICAL POWER RATIO (MCPR)2.1 Limits for Technical Specification 3.1.7.c2.2 Limits for Technical Specification 3.1.7.e3.0 LINEAR HEAT GENERATION RATE (LHGR]3.1 Limits for Technical Specifications 3.1.7.b4.0 POWER/FLOW RELATIONSHIP DURING OPERATION 4.1 Limits for Technical Specification Table 3.1.7.d and e
==5.0 REFERENCES==
FOR TECHNICAL SPECIFICATIONS 6.0 SOURCE DOCUMENTS Pawe101010181820202223Page il COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 011.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR1.1 Limits for Technical Specification 3.1.7.aDuring power operations, the APLHGR(s) for each fuel type as a function of averageplanar exposure shall not exceed the limiting values shown for GEl 1 in Table la, lb,1c, and 1d, or the limiting values shown for GNF2 in Table le, 1f, 1g, and 1h.1.2 Limits for Technical Specification 3.1.7.eDuring partial loop operation with four recirculation loops in operation, the APLHGRas a function of average planar exposure shall not exceeed 98 percent of the limitingvalues shown for GEl 1 in Table la, lb, 1c, and ld and 99 percent of the limitingvalues shown for GNF2 in Table le, If, 1g, and lh.During partial loop operation with three recirculation loops in operation, the APLHGRas a function of average planar exposure shall not exceeed 98 percent of the limitingvalues shown for GEl 1 in Table la, 1b, 1c, and ld and 99 percent of the limitingvalues shown for GNF2 in Table le, If, 1g, and 1h.Page 1 of 23 COLR1 -21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTTable laMAPLHGR LIMITS VERSUS AVERAGE PLANAR EXPOSUREBundle Type: GE11-P9DUB376-12GZ-10OT-145-T6-2586 Average Planar Exposure MAPLHGR Limits (kWlft) (1)GWdlST KWlft0.00 9.630.20 9.631.00 9.605.00 9.4010.00 9.3715.00 9.2420.00 8.7625.00 8.3435.00 8.1045.00 8.0355.00 8.0265.00 6.18(1) These MAPLHGRs are not lattice dependent, therefore the values shown also correspond to thelimiting value for the most limiting lattice for use when hand calculations are required.
Revision 01Page 2 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Table lbMAPLHGR LIMITS VERSUS AVERAGE PLANAR EXPOSUREBundle Type: GE II-P9DUB381-13GZ-1OOT-145-T6-2945 (GEl 1)Average Planar MAPLHGR Limits"'
(kwlft)Exposure Lattice Lattice Lattice Lattice Lattice Lattice MostGWd/ST 7433 7434 7435 7436 7437 7438 Limiting0.00 9.61 9.61 9.57 9.57 9.57 9.57 9.570.20 9.61 9.61 9.57 9.57 9.57 9.57 9.571.00 9.57 9.57 9.56 9.56 9.56 9.56 9.565.00 9.42 9.42 9.46 9.46 9.46 9.46 9.4210.00 9.37 9.37 9.34 9.34 9.34 9.34 9.3415.00 9.22 9.22 9.23 9.23 9.23 9.23 9.2220.00 9.18 9.18 9.19 9.19 9.19 9.19 9.1825.00 8.50 8.50 8.47 8.47 8.47 8.47 8.4735.00 8.19 8.19 8.28 8.28 8.28 8.28 8.1945.00 8.27 8.27 8.27 8.27 8.27 8.27 8.2755.00 8.31 8.31 8.31 8.31 8.31 8.31 8.3165.00 8.38 8.38 8.38 8.38 8.38 8.38 8.38(1) These MAPLHGR are lattice dependent.
The values shown in the Most Limiting Column correspond to thelimiting value for the most limiting lattice for use when hand calculations are required.
Lattice descriptions are contained in the FBIR.Page 3 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Table IcMAPLHGR LIMITS VERSUS AVERAGE PLANAR EXPOSUREBundle Type: GEl 1-P9DUB381-14GZ-1OOT-145-T6-2946 (GEl 1)Average Planar MAPLHGR Limits")
(kwlft)Exposure Lattice Lattice Lattice Lattice Lattice Lattice MostGWdiST 7433 7439 7440 7441 7442 7443 Limiting0.00 10.24 10.24 10.19 10.19 10.19 10.19 10.190.20 10.24 10.24 10.19 10.19 10.19 10.19 10.191.00 10.20 10.20 10.19 10.19 10.19 10.19 10.195.00 9.91 9.91 9.85 9.85 9.85 9.85 9.8510.00 9.42 9.42 9.34 9.34 9.34 9.34 9.3415.00 9.22 9.22 9.19 9.19 9.19 9.19 9.1920.00 9.18 9.18 9.19 9.19 9.19 9.19 9.1825.00 8.64 8.64 8.63 8.63 8.63 8.63 8.6335.00 8.08 8.08 8.08 8.08 8.08 8.08 8.0845.00 8.02 8.02 7.99 7.99 7.99 7.99 7.9955.00 8.00 8.00 7.99 7.99 7.99 7.99 7.9965.00 7.97 7.97 7.96 7.96 7.96 7.96 7.96(1) These MAPLHGR are lattice dependent.
The values shown in the Most Limiting Column correspond to thelimiting value for the most limiting lattice for use when hand calculations are required.
Lattice descriptions are contained in the FBIR.Page 4 of 23 COLRI -21NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTRevision 01Table IdMAPLHGR LIMITS VERSUS AVERAGE PLANAR EXPOSUREBundle Type: GEl I -P9DUB380-13GZ-1 OOT-1 45-T6-2948 (GEl 1)Average Planar MAPLHGR Limits'1 (kwlft)Exposure Lattice Lattice Lattice Lattice Lattice Lattice MostGWdIST 7433 7449 7450 7451 7447 7448 Limiting0.00 9.71 9.71 9.69 9.69 9.69 9.69 9.690.20 9.71 9.71 9.69 9.69 9.69 9.69 9.691.00 9.68 9.68 9.67 9.67 9.67 9.67 9.675.00 9.56 9.56 9.50 9.50 9.50 9.50 9.5010.00 9.38 9.38 9.32 9.32 9.32 9.32 9.3215.00 9.23 9.23 9.24 9.24 9.24 9.24 9.2320.00 9.28 9.28 9.31 9.31 9.31 9.31 9.2825.00 8.43 8.43 8.45 8.45 8.45 8.45 8.4335.00 8.09 8.09 8.09 8.09 8.09 8.09 8.0945.00 7.98 7.98 8.02 8.02 8.02 8.02 7.9855.00 7.97 7.97 7.98 7.98 7.98 7.98 7.9765.00 7.91 7.91 7.93 7.93 7.93 7.93 7.91(1) These MAPLHGR are lattice dependent.
The values shown in the Most Limiting Column correspond to thelimiting value for the most limiting lattice for use when hand calculations are required.
Lattice descriptions are contained in the FBIR.Page 5 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Table leMAPLHGR LIMITS VERSUS AVERAGE PLANAR EXPOSUREBundle Type: GNF2-P10DG2B384-16GZ-100T2-145-T6-3351 (GNF2)Average Planar Exposure MAPLHGR Limits (kWift) (1)GWd/ST KW/ft0.00 8.060.20 8.061.00 7.995.00 7.9710.00 7.8415.00 7.8920.00 7.1925.00 6.9035.00 6.7445.00 6.5355.00 6.4065.00 6.30(1) These MAPLHGRs are not lattice dependent, therefore the values shown also correspond to thelimiting value for the most limiting lattice for use when hand calculations are required.
Page 6 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTTable IfMAPLHGR LIMITS VERSUS AVERAGE PLANAR EXPOSUREBundle Type: GNF2-P10DG2B386-13GZ-100T2-145-T6-3352 (GNF2)Average Planar Exposure MAPLHGR Limits (kW/ft) (1)GWdlST KWIft0.00 8.030.20 8.031.00 8.035.00 7.9610.00 7.8315.00 7.7920.00 7.2425.00 6.9035.00 6.7445.00 6.5455.00 6.3765.00 6.29(1) These MAPLHGRs are not lattice dependent, therefore the values shown also correspond to thelimiting value for the most limiting lattice for use when hand calculations are required.
Revision 01Page 7 of 23 COLRI-21NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTRevision 01Table IgMAPLHGR LIMITS VERSUS AVERAGE PLANAR EXPOSUREBundle Type: GNF2-P10DG2B384-16GZ-100T2-145-T6-4133 (GNF2)Average Planar Exposure MAPLHGR Limits (kW/ft) (1)GWd/ST KWIft0.00 8.070.20 8.071.00 8.065.00 7.9410.00 7.8615.00 7.It20.00 7.1825.00 6.9035.00 6.7345.00 6.5455.00 6.4065.00 6.29(1) These MAPLHGRs are not lattice dependent, therefore the values shown also correspond to the.limiting value for the most limiting lattice for use when hand calculations are required.
Page 8 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Table lhMAPLHGR LIMITS VERSUS AVERAGE PLANAR EXPOSUREBundle Type: GNF2-PI0DG2B386-13GZ-100T2-145-T6-4134 (GNF2)Average Planar Exposure MAPLHGR Limits (kWlft) (1)GWdlST KW/ft0.00 7.980.20 7.981.00 8.035.00 7.9710.00 7.8215.00 7.7920.00 7.2425.00 6.9035.00 6.7445.00 6.5255.00 6.3765.00 6.29(1) These MAPLHGRs are not lattice dependent, therefore the values shown also correspond to thelimiting value for the most limiting lattice for use when hand calculations are required.
Page 9 of 23 COLRI -21 NINE MILE POINT UNIT I Revision 01CORE OPERATING LIMITS REPORT2.0 MINIMUM CRITICAL POWER RATIO (MCPR)2.1 Limits for Technical Specification 3.1.7.cDuring power operation, the operating MCPR shall be greater than or equal to the Operating Limit MCPR determined as the maximum of either:A) the appropriate MCPR11) from Figure (2a thru 2d)(2'31) times the K(f) shown in Figure2e,Or,B) the appropriate MCPR(P)(4) from Figure 2f.Additional MCPR(P) limits are required for operations without a backup pressure regulator.
These limits are shown in Figure 2g.2.2 Limits for Technical Specification 3.1.7.eDuring 3 loop operation, the Operating Limit MCPR shall be increased by 0.03. Noadjustment is needed during 4 loop operation.
NOTES:1 Based on a 1.06 MCPR Safety Limit (SLMCPR)2 For Figures 2a thru 2d tau (T) defined as follows:'r = (Z-.-,. -T-B)/(z-A
-"rB)TA = 0.868 seconds, control rod average scram insertion time limit to notch 39TB =.672+1.65x NI/ N 1N 2 x.016i=I i=1n = number of surveillance tests performed in cycleNi = number of active control rods measured in the ith surveillance testti = average scram time to notch 39 of all rods measured in the iP surveillance testN1 = total number of active rods measured3 For the current exposure and feedwater pump configuration.
"Pump Combinations" are also described inoperating procedure NI-OP-1 6, Attachment 13.4 Introduction of the GNF2 fuel type requires use of power dependent MCPR limits for all off-rated conditions, including operations without a backup pressure regulator.
When power is greater than 45%, the K(P) multiplier from Figure 2f is applied to the applicable rated condition MCPR limits from Figures 2a thru 2d. At less than orequal to 45% power, the MCPR(P) limits in Figure 2f are applied directly.
This discussion also applies to Figure2g. Figure 2f and 2g are applicable to both GEl 1 and GNF2 fuel.Page 10 of 23 COLRI-21NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTRevision 01Figure 2aMCPR Operating Limitsfor Feedwater Pump Combination 1 maximum flowsBeginning Of Cycle to EOR*-3851 MWd/ST(Bounds TDFWP+MDFWP, TDFWP only, MDFWP only, two MDFWPs)1.561.540.C.,6o 1.52ILEi1.5(1, 1.55)(1, 1.50)1.480 0.2 0.4 0.6 0.8Tau* EOR is the end of rated exposure as defined in the Cycle Management ReportPage 11 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Figure 2bMCPR Operating Limitsfor Feedwater Pump Combination I maximum flowsEOR*-3851 MWd/ST to End Of Cycle(Bounds.TDFWP+MDFWP, TDFWP only, MDFWP only, two MDFWPs)1.661.641.62e 1.6' 1.580.1.56E*EEE 1.541.521.51.48(1, 1.64)(1, 1.52)0 0.2 0.4 0.6 0.81Tau* EOR is the end of rated exposure as defined in the Cycle Management ReportPage 12 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Figure 2cMCPR Operating Limitsfor Feedwater Pump Combination 2 maximum flowsBeginning of Cycle to EOR*-3851 MWd/ST(Bounds TDFWP+ two MDFWPs)1.621.61.58S1.560~C.,.21.54E1.521.5(1, 1.60)(1, 1.50)1.480 0.2 0.4 0.6 0.8 1Tau*EOR is the end of rated exposure as defined in the Cycle Management ReportPage 13 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Figure 2dMCPR Operating Limitsfor Feedwater Pump Combination 2 maximum flowsEOR*-3851 MWd/ST to End Of Cycle(Bounds TDFWP+ two MDFWPs)1.721.71.681.66e. 1.64U160 1.6.21.58EEE- 1.561.541.521.5(1, 1.70)(1, 1.56)1.480 0.2 0.4 0.6 0.81Tau* EOR is the end of rated exposure as defined in the Cycle Management ReportPage 14 of 23 COLR11-21 NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Figure 2e NMP-1 K(f) Curve for MCPR1.51.41.30.CL.0'IK(f) = 1.50 when Flow < 45%, Otherwise:
-102.5% K(f)= MAX( 1.0, 1.33075-0.441
* Flow/.100%)
-107.0% K(f)= MAX( 1.0, 1.35280-0.441
* Flow/100%)
-112.0% K(f) = MAX( 1.0, 1.37926-0.441
* Flow/100%)
-117.0% K(f) =.MAX( 1.0, 1.40352 -0.441
* Flow / 100%)-Automatic K(f) = MAX( 1.0, 1.441 -0.441
* Flow /100%)Automatic Flow Control.117% Scoop Tube Setting1 Scoop Tube Setting107% Scoop Tube Setting102.5% Scoof Tube Setting1.21.10.9020406080100120Core Flow (% of Rated)Page 15 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Figure 2fMCPR(P) Limits for Normal Operation 543I I I.[(For 25% < P < 45%* MCPR(P) = [2.91+0.0285(45%-P)]
for Core Flow > 60% Flow* MCPR(P) = [2.33+0.0510(45%-P)]
for Core Flow !5 60% FlowMCPR(P) = K(P)
* the appropriate MCPR Limit from Figures 2athrough 2d for 45% < P <100%* K(P) = [1.216+0.00665(65%-P)]
for 45% !5 P !5 65%* K(P) = [1.133+0.00415(85%-P)]
for 65% 5 P 5 85%* K(P) = [1.000+0.00887(1 00%-P)] for 85% s P !5 100%0~08210020406080100Core Thermal Power (P) in units of % Rated Thermal Power (%RTP)Page 16 of 23 COLRI-21NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTRevision 01Figure 2gMCPR(P) Limits for Operation Without Backup Pressure Regulator
.54IFor 25% < P < 45%* MCPR(P) = [2.91+0.0285(45%-P)]
for Core Flow > 60% Flow* MCPR(P) = [2.33+0.0510(45%-P)]
for Core Flow < 60% FlowMCPR(P) = K(P)
* the appropriate MCPR Limit from Figures 2a through2d for 45% < P < 100%* K(P) = [1.336+0.01085(65%-P)]
for 45% < P < 65%* K(P) = [1.198+0.00690(85%-P)]
for 65% < P < 85%* K(P) = [1.000+0.00887(1 00%-P)] for 85% < P 5 100%F ICore Flow > 60%3ILad,210Core Flow < 60%020406080100Core Thermal Power (P) in units of % Rated Thermal Power (%RTP)Page 17 of 23 COLRI-21NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTRevision 013.0 LINEAR HEAT GENERATION RATE (LHGR)3.1 Limits for Technical Specification 3.11.7.bDuring power operation, the Linear Heat Generation Rate (LHGR) for all fuel bundles at any rod at anyaxial location shall not exceed either 11.0kW/ft(1) or the U02 LHGR limits shown in FBIRI-21, Rev 01,"Nine Mile Point Unit 1 Fuel Bundle Information Report" or:-The limiting values shown in MFN 11-194, "GNF2 Advantage Generic Compliance with NEDE-2401 10POA (GESTAR II), NEDC-33270P, Revision 4, October 2011" for GNF2 fuel bundles; or-The limiting values shown in 0000-0144-8220, Rev 00, "NMP1 Cycle 23 GEl 1 LHGR Limits" forGEl 1 fuel bundles.Compliance with these limits will be monitored by the plant's process computer.
For power operations between 45% and 100% RTP(2) without a backup pressure regulator, operating MFLPD shall be < LHGRFAC(P)(
3).NOTE:1 GNF2 LHGR limit has been set down to a maximum value of 11 kW/ft to address Emergency Procedure Guidelines (EPG) requirements.
2 Introduction of the GNF2 fuel type requires use of a power dependent LHGR Correction Factor, or LHGRFAC(P) for power operations without a backup pressure regulator at greater than or equal to 45% RTP. Below 45% RTP,no additional limits are required.
Figure 3 is applicable to both GEl 1 and GNF2 fuel types.3 LHGRFAC(P) limits are provided for option B and option A scram times. If scram times are slower than option B(i.e. T > 0), then option A limits must be applied.Page 18 of 23 COLRI-21NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTRevision 01Figure 3LHGRFAC(P)
Limits for Operation Without Backup Pressure Regulator 1.21.00.8" 0.6"-J0.40.20.0I Operating MFLPD shall be-< LHGRFAC(P)
/i- iOption BOption AOption A (T > 0)ILHGRFAC(P)
= [0.518] for 45% < P < 65%mLHGRFAC(P)
= [0.636 -0.00590(85%
-P)] for 65% < P < 85%NLHGRFAC(P)
= [1.000 -0.02427(100%
-P)] for 85% < P < 100%Option B (T = 0)*LHGRFAC(P)
= [0.867 -0.00650(65%
-P)] for 45% < P < 65%LHGRFAC(P)
= [0.987 -0.00600(85%
-P)] for 65% 5 P 5 85%LHGRFAC(P)
= [1.000 -0.00087(100%
-P)] for 85% < P < 100%45 50 55 60 65 70 75 80 85 90 95 100Core Thermal Power (P) in units of % Rated Thermal Power (%RTP)Page 19 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 014.0 POWER/FLOW RELATIONSHIP DURING OPERATION 4.1 Limits for Technical Specification 3.1.7.d and eThe power/flow relationship shall not exceed the limiting values shown in Figure 4.Page 20 of 23 COLRI-21NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTFigure 4 Limiting Power/ Flow LineRevision 01120.00100.000880.0060.0040.0020.000.000 20 40 60 80 100Core Flow (%of Rated)120Page 21 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 015.0 REFERENCE FOR TECHNICAL SPECIFICATIONS Technical Specification 6.6.5b:NEDE 24011-P-A-19, "General Electric Standard Application for Reactor Fuel,"May 2012 and the U.S. Supplement, NEDE-2401 1-P-A-1 9-US, May 2012.Page 22 of 23 COLRI-21NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTRevision 016.0 SOURCE DOCUMENTS The Core Operating Limits contained in this report were~obtained from the following documents:
CORE OPERATING LIMITSREFERENCES APLHGR Limits (Section 1)Table la -hand corresponding 3 and 4 loop multipliers Lattice Descriptions MCPR Limits (Section 2)0000-0144-8266-SRLR, Revision 1, Supplemental Reload Licensing Report for Nine Mile Point 1 Reload22 Cycle 21, March 2013FBIR1-21, Revision 1, Nine Mile Point Unit 1 FuelBundle Information Report, April 20130000-0144-8266-SRLR, Revision 1, Supplemental Reload Licensing Report for Nine Mile Point 1 Reload22 Cycle 21, March 20130000-0156-5878, Revision 1, Nine Mile Point 1 Cycle23 Cycle-Specific Offrated Power Dependent LimitsBelow Pbypass with Turbine Bypass, April 2, 2013EOR Definition LHGR Limits (Section 3)(GEl 1)(GNF2)CMR1-21, Revision 0, Nine Mile Point Unit 1, Cycle21, Cycle Management Report, May 20130000-0144-8266-SRLR, Revision 1, Supplemental Reload Licensing Report for Nine Mile Point 1 Reload22 Cycle 21, March 2013FBIR1-21, Revision 1, Nine Mile Point Unit 1 FuelBundle Information Report, April 20130000-0144-8220, Revision 0, NMPI. Cycle 23 GE11LHGR Limits, September 5,. 2013MFN 11-194, Letter from A.A. Lingenfelter (GNF) to.Document Control Desk (NRC),
==Subject:==
"GNF2Advantage Generic Compliance with NEDE-24011-P-A (GESTAR II), NEDC-33270P, Revision 4, October2011," October 21,:2011NMP1 Technical Specification Amendment 92, Figure3.1.7.aaPower/Flow Relationship (Section 4)Page 23 of 23}}

Revision as of 16:04, 3 July 2018

Nine Mile Point Nuclear Station - Submittal of Core Operating Limits Report
ML13318A009
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 11/05/2013
From: Swift P M
Constellation Energy Nuclear Group, EDF Group, Nine Mile Point
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML13318A009 (29)


Text

CENG.a joint venture ofConstellation

~E~eDFEnergy* 0NINE MILE POINTNUCLEAR STATIONNovember 5, 2013U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 ATTENTION:

SUBJECT:

Document Control DeskNine Mile Point Nuclear StationRenewed Facility Operating License No. DPR-63Unit No. 1; Docket No. 50-220Core Operating Limits ReportEnclosed is a copy of the Core Operating Limits Report, COLR1-21, Revision 1 for Nine Mile Point Unit1 (NMP1). This report is being submitted pursuant to NMPI Technical Specification 6.6.5.d.

TheCOLR is being revised to provide a more robust description of Linear Heat Generation Rates (LHGR)values and their source documentation based on an internal Quality Assurance observation.

Should you have any questions regarding the information in this submittal, please contact Everett P.Perkins, Director

-Licensing, at (315) 349-5219.

Very truly yours,Paul M. SwiftManager, Engineering ServicesPMS/MHS

Enclosure:

Nine Mile Point Unit 1 Core Operating Limits ReportNine Mile Point Nuclear Station, LLCP.O. Box 63, Lycoming, NY 13093 Document Control DeskNovember 5, 2013Page 2cc: NRC Regional Administrator, Region INRC Project ManagerNRC Senior Resident Inspector ENCLOSURE Nine Mile Point Unit 1Core Operating Limits ReportNine Mile Point Nuclear Station, LLCNovember 5, 2013 NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTDocument No.:COLRI-21Revision 01NameTitleDatePrepared by:Reviewed by:Approved by:Approved by:Approved by:obert CloseJohn DarweeshPhil Wengloski Pi'sA' LFuelsEngineerFuelsEngineerSupervisor, Nuclear FuelServicesSupervisor, ReactorEngineering GeneralSupervisor, Nuclear FuelServices/0/.22/13

/0 Z//ziol4.111-This Controlled Document provides cycle specific core operating limits for use in conjunction with the Nine Mile Point Unit I Technical Specifications.

Document pages may only be changedthrough a reissue of the entire document.

COLRI-21 NINE MILE POINT UNIT I Revision 01CORE OPERATING LIMITS REPORTTERMS AND DEFINITIONS Averaqe Planar Linear Heat Generation Rate (APLHGR)The Average Planar Linear Heat Generation Rate (APLHGR) shall be applicable to a specific planarheight and is equal to the sum of the heat generation rate per unit length of fuel rod for all fuel rodsin the specified bundle at the specified height, divided by the number of fuel rods in the fuel bundleat that heightBOCBeginning of CycleMaxiumum Fraction of Limiting Power Density (MFLPD)The highest value of the fraction of limiting power density which exists in the coreEOREnd of Rated Conditions (i.e. cycle exposure at 100% power, 100% flow, all rods-out, all feedwater heaters in service and equilibrium xenon)MCPR flow dependent multiplier K(P)MCPR power dependent multiplier LHGRFAC(P)

Power dependent LHGR correction factorLinear Heat Generation Rate (LHGR)The heat generation per unit length of fuel rod. It is the integral of the heat flux over the heattransfer area associated with the fuel lengthMAPLHGRMaximum Average Planar Linear Heat Generation RateMinimum Critical Power Ratio (MCPR)The minimum in-core critical power ratioFBIRFuel Bundle Information ReportMDFWPMotor driven feedwater pumpTDFWPTurbine driven feedwater pumpPage i COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Table of Contents1.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)1.1 Limits for Technical Specification 3.1.7.a1.2 Limits for Technical Specification 3.1.7.e2.0 MINIMUM CRITICAL POWER RATIO (MCPR)2.1 Limits for Technical Specification 3.1.7.c2.2 Limits for Technical Specification 3.1.7.e3.0 LINEAR HEAT GENERATION RATE (LHGR]3.1 Limits for Technical Specifications 3.1.7.b4.0 POWER/FLOW RELATIONSHIP DURING OPERATION 4.1 Limits for Technical Specification Table 3.1.7.d and e

5.0 REFERENCES

FOR TECHNICAL SPECIFICATIONS 6.0 SOURCE DOCUMENTS Pawe101010181820202223Page il COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 011.0 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR1.1 Limits for Technical Specification 3.1.7.aDuring power operations, the APLHGR(s) for each fuel type as a function of averageplanar exposure shall not exceed the limiting values shown for GEl 1 in Table la, lb,1c, and 1d, or the limiting values shown for GNF2 in Table le, 1f, 1g, and 1h.1.2 Limits for Technical Specification 3.1.7.eDuring partial loop operation with four recirculation loops in operation, the APLHGRas a function of average planar exposure shall not exceeed 98 percent of the limitingvalues shown for GEl 1 in Table la, lb, 1c, and ld and 99 percent of the limitingvalues shown for GNF2 in Table le, If, 1g, and lh.During partial loop operation with three recirculation loops in operation, the APLHGRas a function of average planar exposure shall not exceeed 98 percent of the limitingvalues shown for GEl 1 in Table la, 1b, 1c, and ld and 99 percent of the limitingvalues shown for GNF2 in Table le, If, 1g, and 1h.Page 1 of 23 COLR1 -21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTTable laMAPLHGR LIMITS VERSUS AVERAGE PLANAR EXPOSUREBundle Type: GE11-P9DUB376-12GZ-10OT-145-T6-2586 Average Planar Exposure MAPLHGR Limits (kWlft) (1)GWdlST KWlft0.00 9.630.20 9.631.00 9.605.00 9.4010.00 9.3715.00 9.2420.00 8.7625.00 8.3435.00 8.1045.00 8.0355.00 8.0265.00 6.18(1) These MAPLHGRs are not lattice dependent, therefore the values shown also correspond to thelimiting value for the most limiting lattice for use when hand calculations are required.

Revision 01Page 2 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Table lbMAPLHGR LIMITS VERSUS AVERAGE PLANAR EXPOSUREBundle Type: GE II-P9DUB381-13GZ-1OOT-145-T6-2945 (GEl 1)Average Planar MAPLHGR Limits"'

(kwlft)Exposure Lattice Lattice Lattice Lattice Lattice Lattice MostGWd/ST 7433 7434 7435 7436 7437 7438 Limiting0.00 9.61 9.61 9.57 9.57 9.57 9.57 9.570.20 9.61 9.61 9.57 9.57 9.57 9.57 9.571.00 9.57 9.57 9.56 9.56 9.56 9.56 9.565.00 9.42 9.42 9.46 9.46 9.46 9.46 9.4210.00 9.37 9.37 9.34 9.34 9.34 9.34 9.3415.00 9.22 9.22 9.23 9.23 9.23 9.23 9.2220.00 9.18 9.18 9.19 9.19 9.19 9.19 9.1825.00 8.50 8.50 8.47 8.47 8.47 8.47 8.4735.00 8.19 8.19 8.28 8.28 8.28 8.28 8.1945.00 8.27 8.27 8.27 8.27 8.27 8.27 8.2755.00 8.31 8.31 8.31 8.31 8.31 8.31 8.3165.00 8.38 8.38 8.38 8.38 8.38 8.38 8.38(1) These MAPLHGR are lattice dependent.

The values shown in the Most Limiting Column correspond to thelimiting value for the most limiting lattice for use when hand calculations are required.

Lattice descriptions are contained in the FBIR.Page 3 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Table IcMAPLHGR LIMITS VERSUS AVERAGE PLANAR EXPOSUREBundle Type: GEl 1-P9DUB381-14GZ-1OOT-145-T6-2946 (GEl 1)Average Planar MAPLHGR Limits")

(kwlft)Exposure Lattice Lattice Lattice Lattice Lattice Lattice MostGWdiST 7433 7439 7440 7441 7442 7443 Limiting0.00 10.24 10.24 10.19 10.19 10.19 10.19 10.190.20 10.24 10.24 10.19 10.19 10.19 10.19 10.191.00 10.20 10.20 10.19 10.19 10.19 10.19 10.195.00 9.91 9.91 9.85 9.85 9.85 9.85 9.8510.00 9.42 9.42 9.34 9.34 9.34 9.34 9.3415.00 9.22 9.22 9.19 9.19 9.19 9.19 9.1920.00 9.18 9.18 9.19 9.19 9.19 9.19 9.1825.00 8.64 8.64 8.63 8.63 8.63 8.63 8.6335.00 8.08 8.08 8.08 8.08 8.08 8.08 8.0845.00 8.02 8.02 7.99 7.99 7.99 7.99 7.9955.00 8.00 8.00 7.99 7.99 7.99 7.99 7.9965.00 7.97 7.97 7.96 7.96 7.96 7.96 7.96(1) These MAPLHGR are lattice dependent.

The values shown in the Most Limiting Column correspond to thelimiting value for the most limiting lattice for use when hand calculations are required.

Lattice descriptions are contained in the FBIR.Page 4 of 23 COLRI -21NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTRevision 01Table IdMAPLHGR LIMITS VERSUS AVERAGE PLANAR EXPOSUREBundle Type: GEl I -P9DUB380-13GZ-1 OOT-1 45-T6-2948 (GEl 1)Average Planar MAPLHGR Limits'1 (kwlft)Exposure Lattice Lattice Lattice Lattice Lattice Lattice MostGWdIST 7433 7449 7450 7451 7447 7448 Limiting0.00 9.71 9.71 9.69 9.69 9.69 9.69 9.690.20 9.71 9.71 9.69 9.69 9.69 9.69 9.691.00 9.68 9.68 9.67 9.67 9.67 9.67 9.675.00 9.56 9.56 9.50 9.50 9.50 9.50 9.5010.00 9.38 9.38 9.32 9.32 9.32 9.32 9.3215.00 9.23 9.23 9.24 9.24 9.24 9.24 9.2320.00 9.28 9.28 9.31 9.31 9.31 9.31 9.2825.00 8.43 8.43 8.45 8.45 8.45 8.45 8.4335.00 8.09 8.09 8.09 8.09 8.09 8.09 8.0945.00 7.98 7.98 8.02 8.02 8.02 8.02 7.9855.00 7.97 7.97 7.98 7.98 7.98 7.98 7.9765.00 7.91 7.91 7.93 7.93 7.93 7.93 7.91(1) These MAPLHGR are lattice dependent.

The values shown in the Most Limiting Column correspond to thelimiting value for the most limiting lattice for use when hand calculations are required.

Lattice descriptions are contained in the FBIR.Page 5 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Table leMAPLHGR LIMITS VERSUS AVERAGE PLANAR EXPOSUREBundle Type: GNF2-P10DG2B384-16GZ-100T2-145-T6-3351 (GNF2)Average Planar Exposure MAPLHGR Limits (kWift) (1)GWd/ST KW/ft0.00 8.060.20 8.061.00 7.995.00 7.9710.00 7.8415.00 7.8920.00 7.1925.00 6.9035.00 6.7445.00 6.5355.00 6.4065.00 6.30(1) These MAPLHGRs are not lattice dependent, therefore the values shown also correspond to thelimiting value for the most limiting lattice for use when hand calculations are required.

Page 6 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTTable IfMAPLHGR LIMITS VERSUS AVERAGE PLANAR EXPOSUREBundle Type: GNF2-P10DG2B386-13GZ-100T2-145-T6-3352 (GNF2)Average Planar Exposure MAPLHGR Limits (kW/ft) (1)GWdlST KWIft0.00 8.030.20 8.031.00 8.035.00 7.9610.00 7.8315.00 7.7920.00 7.2425.00 6.9035.00 6.7445.00 6.5455.00 6.3765.00 6.29(1) These MAPLHGRs are not lattice dependent, therefore the values shown also correspond to thelimiting value for the most limiting lattice for use when hand calculations are required.

Revision 01Page 7 of 23 COLRI-21NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTRevision 01Table IgMAPLHGR LIMITS VERSUS AVERAGE PLANAR EXPOSUREBundle Type: GNF2-P10DG2B384-16GZ-100T2-145-T6-4133 (GNF2)Average Planar Exposure MAPLHGR Limits (kW/ft) (1)GWd/ST KWIft0.00 8.070.20 8.071.00 8.065.00 7.9410.00 7.8615.00 7.It20.00 7.1825.00 6.9035.00 6.7345.00 6.5455.00 6.4065.00 6.29(1) These MAPLHGRs are not lattice dependent, therefore the values shown also correspond to the.limiting value for the most limiting lattice for use when hand calculations are required.

Page 8 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Table lhMAPLHGR LIMITS VERSUS AVERAGE PLANAR EXPOSUREBundle Type: GNF2-PI0DG2B386-13GZ-100T2-145-T6-4134 (GNF2)Average Planar Exposure MAPLHGR Limits (kWlft) (1)GWdlST KW/ft0.00 7.980.20 7.981.00 8.035.00 7.9710.00 7.8215.00 7.7920.00 7.2425.00 6.9035.00 6.7445.00 6.5255.00 6.3765.00 6.29(1) These MAPLHGRs are not lattice dependent, therefore the values shown also correspond to thelimiting value for the most limiting lattice for use when hand calculations are required.

Page 9 of 23 COLRI -21 NINE MILE POINT UNIT I Revision 01CORE OPERATING LIMITS REPORT2.0 MINIMUM CRITICAL POWER RATIO (MCPR)2.1 Limits for Technical Specification 3.1.7.cDuring power operation, the operating MCPR shall be greater than or equal to the Operating Limit MCPR determined as the maximum of either:A) the appropriate MCPR11) from Figure (2a thru 2d)(2'31) times the K(f) shown in Figure2e,Or,B) the appropriate MCPR(P)(4) from Figure 2f.Additional MCPR(P) limits are required for operations without a backup pressure regulator.

These limits are shown in Figure 2g.2.2 Limits for Technical Specification 3.1.7.eDuring 3 loop operation, the Operating Limit MCPR shall be increased by 0.03. Noadjustment is needed during 4 loop operation.

NOTES:1 Based on a 1.06 MCPR Safety Limit (SLMCPR)2 For Figures 2a thru 2d tau (T) defined as follows:'r = (Z-.-,. -T-B)/(z-A

-"rB)TA = 0.868 seconds, control rod average scram insertion time limit to notch 39TB =.672+1.65x NI/ N 1N 2 x.016i=I i=1n = number of surveillance tests performed in cycleNi = number of active control rods measured in the ith surveillance testti = average scram time to notch 39 of all rods measured in the iP surveillance testN1 = total number of active rods measured3 For the current exposure and feedwater pump configuration.

"Pump Combinations" are also described inoperating procedure NI-OP-1 6, Attachment 13.4 Introduction of the GNF2 fuel type requires use of power dependent MCPR limits for all off-rated conditions, including operations without a backup pressure regulator.

When power is greater than 45%, the K(P) multiplier from Figure 2f is applied to the applicable rated condition MCPR limits from Figures 2a thru 2d. At less than orequal to 45% power, the MCPR(P) limits in Figure 2f are applied directly.

This discussion also applies to Figure2g. Figure 2f and 2g are applicable to both GEl 1 and GNF2 fuel.Page 10 of 23 COLRI-21NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTRevision 01Figure 2aMCPR Operating Limitsfor Feedwater Pump Combination 1 maximum flowsBeginning Of Cycle to EOR*-3851 MWd/ST(Bounds TDFWP+MDFWP, TDFWP only, MDFWP only, two MDFWPs)1.561.540.C.,6o 1.52ILEi1.5(1, 1.55)(1, 1.50)1.480 0.2 0.4 0.6 0.8Tau* EOR is the end of rated exposure as defined in the Cycle Management ReportPage 11 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Figure 2bMCPR Operating Limitsfor Feedwater Pump Combination I maximum flowsEOR*-3851 MWd/ST to End Of Cycle(Bounds.TDFWP+MDFWP, TDFWP only, MDFWP only, two MDFWPs)1.661.641.62e 1.6' 1.580.1.56E*EEE 1.541.521.51.48(1, 1.64)(1, 1.52)0 0.2 0.4 0.6 0.81Tau* EOR is the end of rated exposure as defined in the Cycle Management ReportPage 12 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Figure 2cMCPR Operating Limitsfor Feedwater Pump Combination 2 maximum flowsBeginning of Cycle to EOR*-3851 MWd/ST(Bounds TDFWP+ two MDFWPs)1.621.61.58S1.560~C.,.21.54E1.521.5(1, 1.60)(1, 1.50)1.480 0.2 0.4 0.6 0.8 1Tau*EOR is the end of rated exposure as defined in the Cycle Management ReportPage 13 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Figure 2dMCPR Operating Limitsfor Feedwater Pump Combination 2 maximum flowsEOR*-3851 MWd/ST to End Of Cycle(Bounds TDFWP+ two MDFWPs)1.721.71.681.66e. 1.64U160 1.6.21.58EEE- 1.561.541.521.5(1, 1.70)(1, 1.56)1.480 0.2 0.4 0.6 0.81Tau* EOR is the end of rated exposure as defined in the Cycle Management ReportPage 14 of 23 COLR11-21 NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Figure 2e NMP-1 K(f) Curve for MCPR1.51.41.30.CL.0'IK(f) = 1.50 when Flow < 45%, Otherwise:

-102.5% K(f)= MAX( 1.0, 1.33075-0.441

  • Flow/.100%)

-107.0% K(f)= MAX( 1.0, 1.35280-0.441

  • Flow/100%)

-112.0% K(f) = MAX( 1.0, 1.37926-0.441

  • Flow/100%)

-117.0% K(f) =.MAX( 1.0, 1.40352 -0.441

  • Flow / 100%)-Automatic K(f) = MAX( 1.0, 1.441 -0.441
  • Flow /100%)Automatic Flow Control.117% Scoop Tube Setting1 Scoop Tube Setting107% Scoop Tube Setting102.5% Scoof Tube Setting1.21.10.9020406080100120Core Flow (% of Rated)Page 15 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 01Figure 2fMCPR(P) Limits for Normal Operation 543I I I.[(For 25% < P < 45%* MCPR(P) = [2.91+0.0285(45%-P)]

for Core Flow > 60% Flow* MCPR(P) = [2.33+0.0510(45%-P)]

for Core Flow !5 60% FlowMCPR(P) = K(P)

  • the appropriate MCPR Limit from Figures 2athrough 2d for 45% < P <100%* K(P) = [1.216+0.00665(65%-P)]

for 45% !5 P !5 65%* K(P) = [1.133+0.00415(85%-P)]

for 65% 5 P 5 85%* K(P) = [1.000+0.00887(1 00%-P)] for 85% s P !5 100%0~08210020406080100Core Thermal Power (P) in units of % Rated Thermal Power (%RTP)Page 16 of 23 COLRI-21NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTRevision 01Figure 2gMCPR(P) Limits for Operation Without Backup Pressure Regulator

.54IFor 25% < P < 45%* MCPR(P) = [2.91+0.0285(45%-P)]

for Core Flow > 60% Flow* MCPR(P) = [2.33+0.0510(45%-P)]

for Core Flow < 60% FlowMCPR(P) = K(P)

  • the appropriate MCPR Limit from Figures 2a through2d for 45% < P < 100%* K(P) = [1.336+0.01085(65%-P)]

for 45% < P < 65%* K(P) = [1.198+0.00690(85%-P)]

for 65% < P < 85%* K(P) = [1.000+0.00887(1 00%-P)] for 85% < P 5 100%F ICore Flow > 60%3ILad,210Core Flow < 60%020406080100Core Thermal Power (P) in units of % Rated Thermal Power (%RTP)Page 17 of 23 COLRI-21NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTRevision 013.0 LINEAR HEAT GENERATION RATE (LHGR)3.1 Limits for Technical Specification 3.11.7.bDuring power operation, the Linear Heat Generation Rate (LHGR) for all fuel bundles at any rod at anyaxial location shall not exceed either 11.0kW/ft(1) or the U02 LHGR limits shown in FBIRI-21, Rev 01,"Nine Mile Point Unit 1 Fuel Bundle Information Report" or:-The limiting values shown in MFN 11-194, "GNF2 Advantage Generic Compliance with NEDE-2401 10POA (GESTAR II), NEDC-33270P, Revision 4, October 2011" for GNF2 fuel bundles; or-The limiting values shown in 0000-0144-8220, Rev 00, "NMP1 Cycle 23 GEl 1 LHGR Limits" forGEl 1 fuel bundles.Compliance with these limits will be monitored by the plant's process computer.

For power operations between 45% and 100% RTP(2) without a backup pressure regulator, operating MFLPD shall be < LHGRFAC(P)(

3).NOTE:1 GNF2 LHGR limit has been set down to a maximum value of 11 kW/ft to address Emergency Procedure Guidelines (EPG) requirements.

2 Introduction of the GNF2 fuel type requires use of a power dependent LHGR Correction Factor, or LHGRFAC(P) for power operations without a backup pressure regulator at greater than or equal to 45% RTP. Below 45% RTP,no additional limits are required.

Figure 3 is applicable to both GEl 1 and GNF2 fuel types.3 LHGRFAC(P) limits are provided for option B and option A scram times. If scram times are slower than option B(i.e. T > 0), then option A limits must be applied.Page 18 of 23 COLRI-21NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTRevision 01Figure 3LHGRFAC(P)

Limits for Operation Without Backup Pressure Regulator 1.21.00.8" 0.6"-J0.40.20.0I Operating MFLPD shall be-< LHGRFAC(P)

/i- iOption BOption AOption A (T > 0)ILHGRFAC(P)

= [0.518] for 45% < P < 65%mLHGRFAC(P)

= [0.636 -0.00590(85%

-P)] for 65% < P < 85%NLHGRFAC(P)

= [1.000 -0.02427(100%

-P)] for 85% < P < 100%Option B (T = 0)*LHGRFAC(P)

= [0.867 -0.00650(65%

-P)] for 45% < P < 65%LHGRFAC(P)

= [0.987 -0.00600(85%

-P)] for 65% 5 P 5 85%LHGRFAC(P)

= [1.000 -0.00087(100%

-P)] for 85% < P < 100%45 50 55 60 65 70 75 80 85 90 95 100Core Thermal Power (P) in units of % Rated Thermal Power (%RTP)Page 19 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 014.0 POWER/FLOW RELATIONSHIP DURING OPERATION 4.1 Limits for Technical Specification 3.1.7.d and eThe power/flow relationship shall not exceed the limiting values shown in Figure 4.Page 20 of 23 COLRI-21NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTFigure 4 Limiting Power/ Flow LineRevision 01120.00100.000880.0060.0040.0020.000.000 20 40 60 80 100Core Flow (%of Rated)120Page 21 of 23 COLRI-21NINE MILE POINT UNIT ICORE OPERATING LIMITS REPORTRevision 015.0 REFERENCE FOR TECHNICAL SPECIFICATIONS Technical Specification 6.6.5b:NEDE 24011-P-A-19, "General Electric Standard Application for Reactor Fuel,"May 2012 and the U.S. Supplement, NEDE-2401 1-P-A-1 9-US, May 2012.Page 22 of 23 COLRI-21NINE MILE POINT UNIT 1CORE OPERATING LIMITS REPORTRevision 016.0 SOURCE DOCUMENTS The Core Operating Limits contained in this report were~obtained from the following documents:

CORE OPERATING LIMITSREFERENCES APLHGR Limits (Section 1)Table la -hand corresponding 3 and 4 loop multipliers Lattice Descriptions MCPR Limits (Section 2)0000-0144-8266-SRLR, Revision 1, Supplemental Reload Licensing Report for Nine Mile Point 1 Reload22 Cycle 21, March 2013FBIR1-21, Revision 1, Nine Mile Point Unit 1 FuelBundle Information Report, April 20130000-0144-8266-SRLR, Revision 1, Supplemental Reload Licensing Report for Nine Mile Point 1 Reload22 Cycle 21, March 20130000-0156-5878, Revision 1, Nine Mile Point 1 Cycle23 Cycle-Specific Offrated Power Dependent LimitsBelow Pbypass with Turbine Bypass, April 2, 2013EOR Definition LHGR Limits (Section 3)(GEl 1)(GNF2)CMR1-21, Revision 0, Nine Mile Point Unit 1, Cycle21, Cycle Management Report, May 20130000-0144-8266-SRLR, Revision 1, Supplemental Reload Licensing Report for Nine Mile Point 1 Reload22 Cycle 21, March 2013FBIR1-21, Revision 1, Nine Mile Point Unit 1 FuelBundle Information Report, April 20130000-0144-8220, Revision 0, NMPI. Cycle 23 GE11LHGR Limits, September 5,. 2013MFN 11-194, Letter from A.A. Lingenfelter (GNF) to.Document Control Desk (NRC),

Subject:

"GNF2Advantage Generic Compliance with NEDE-24011-P-A (GESTAR II), NEDC-33270P, Revision 4, October2011," October 21,:2011NMP1 Technical Specification Amendment 92, Figure3.1.7.aaPower/Flow Relationship (Section 4)Page 23 of 23