ML15020A478: Difference between revisions
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
||
Line 18: | Line 18: | ||
=Text= | =Text= | ||
{{#Wiki_filter:1NRR-PMDAPEm | {{#Wiki_filter:1NRR-PMDAPEm Resource From:Saba, Farideh Sent:Tuesday, January 20, 2015 11:44 AM To:ken.frehafer@fpl.com; Lewis, At anya (Atanya.Lewis@fpl.com) | ||
Cc:eric.katzman@fpl.com | |||
==Subject:== | ==Subject:== | ||
Acceptance Review of St. Lucie's LAR to Adopt TSTF-505 (MF5372/73)Importance:HighKen and Atanya, By letter dated December 5, 2014 (Agencywide Documents Access and Management System Accession No. ML14353A016), Florida Power & Light Company, et al. (the licensee), requested a license amendment for the St. Lucie Nuclear Plant, Units 1 and 2. The proposed amendments would modify TS requirements to permit the use of Risk Informed Completion Times in accordance with TSTF-505, Revision 1, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b." The availability of this TS improvement was announced in the Federal Register on March 15, 2012 (77 FR 15399). This email provides the results of the U.S. Nuclear Regulatory Commission (NRC) staff's | Acceptance Review of St. Lucie's LAR to Adopt TSTF-505 (MF5372/73) | ||
If you have any questions, please | Importance: | ||
HighKen and Atanya, | |||
By letter dated December 5, 2014 (Agencywide Documents Access and Management System Accession No. ML14353A016), Florida Power & Light Company, et al. (the licensee), requested a license amendment for the St. Lucie Nuclear Plant, Units 1 and 2. The proposed amendments would modify TS requirements to permit the use of Risk Informed Completion Times in accordance with TSTF-505, Revision 1, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b." The availability of this TS improvement was announced in the Federal Register on March 15, 2012 (77 FR 15399). This email provides the results of the U.S. Nuclear | |||
Regulatory Commission (NRC) staff's acc eptance review of this application. | |||
The NRC performed an acceptance review of the applicat ion to determine if the scope and depth of technical information is sufficient for the NRC staff to complete it s detailed technical review. The acceptance review also intends to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant. | |||
The NRC staff concluded that the licensee's submittal provides technical information in sufficient detail to enable the NRC staff to complete its detailed te chnical review and make an independent assessment regarding the acceptability of the proposed request in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be in stances in which the NRC staff identifies issues that affect its ability to complete the detailed technical review despite completion of an adequate acceptance | |||
review. If the NRC staff needs additional information, it will notify the licensee by separate correspondence. | |||
If you have any questions, please contac t me at (301) 415-1447 or via email Farideh.saba@nrc.gov | |||
. Farideh E. Saba, P.E. Senior Project Manager NRC/ADRO/NRR/DORL 301-415-1447 Mail Stop O-8G9A Farideh.Saba@NRC.GOV | |||
Hearing Identifier: NRR_PMDA Email Number: 1821 Mail Envelope Properties (Farideh.Saba@nrc.gov20150120114300) | |||
==Subject:== | ==Subject:== | ||
Acceptance Review of St. Lucie's LAR to Adopt TSTF-505 (MF5372/73) Sent Date: 1/20/2015 11:43:46 AM Received Date: 1/20/2015 11:43:00 AM | Acceptance Review of St. Lucie's LAR to Adopt TSTF-505 (MF5372/73) Sent Date: 1/20/2015 11:43:46 AM Received Date: 1/20/2015 11:43:00 AM From: Saba, Farideh Created By: Farideh.Saba@nrc.gov Recipients: "eric.katzman@fpl.com" <eric.katzman@fpl.com> | ||
Tracking Status: None "ken.frehafer@fpl.com" <ken.frehafer@fpl.com> | Tracking Status: None "ken.frehafer@fpl.com" <ken.frehafer@fpl.com> | ||
Tracking Status: None "Lewis, Atanya (Atanya.Lewis@fpl.com)" <Atanya.Lewis@fpl.com> Tracking Status: None | Tracking Status: None "Lewis, Atanya (Atanya.Lewis@fpl.com)" <Atanya.Lewis@fpl.com> Tracking Status: None | ||
Post Office: Files Size Date & Time | Post Office: Files Size Date & Time MESSAGE 2197 1/20/2015 11:43:00 AM Options Priority: High Return Notification: No Reply Requested: Yes Sensitivity: Normal Expiration Date: Recipients Received:}} |
Revision as of 05:20, 1 July 2018
ML15020A478 | |
Person / Time | |
---|---|
Site: | Saint Lucie |
Issue date: | 01/20/2015 |
From: | Saba F E Plant Licensing Branch II |
To: | Frehafer K W Florida Power & Light Co |
References | |
TAC MF5372, TAC MF5373 | |
Download: ML15020A478 (2) | |
Text
1NRR-PMDAPEm Resource From:Saba, Farideh Sent:Tuesday, January 20, 2015 11:44 AM To:ken.frehafer@fpl.com; Lewis, At anya (Atanya.Lewis@fpl.com)
Cc:eric.katzman@fpl.com
Subject:
Acceptance Review of St. Lucie's LAR to Adopt TSTF-505 (MF5372/73)
Importance:
HighKen and Atanya,
By letter dated December 5, 2014 (Agencywide Documents Access and Management System Accession No. ML14353A016), Florida Power & Light Company, et al. (the licensee), requested a license amendment for the St. Lucie Nuclear Plant, Units 1 and 2. The proposed amendments would modify TS requirements to permit the use of Risk Informed Completion Times in accordance with TSTF-505, Revision 1, "Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b." The availability of this TS improvement was announced in the Federal Register on March 15, 2012 (77 FR 15399). This email provides the results of the U.S. Nuclear
Regulatory Commission (NRC) staff's acc eptance review of this application.
The NRC performed an acceptance review of the applicat ion to determine if the scope and depth of technical information is sufficient for the NRC staff to complete it s detailed technical review. The acceptance review also intends to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.
The NRC staff concluded that the licensee's submittal provides technical information in sufficient detail to enable the NRC staff to complete its detailed te chnical review and make an independent assessment regarding the acceptability of the proposed request in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be in stances in which the NRC staff identifies issues that affect its ability to complete the detailed technical review despite completion of an adequate acceptance
review. If the NRC staff needs additional information, it will notify the licensee by separate correspondence.
If you have any questions, please contac t me at (301) 415-1447 or via email Farideh.saba@nrc.gov
. Farideh E. Saba, P.E. Senior Project Manager NRC/ADRO/NRR/DORL 301-415-1447 Mail Stop O-8G9A Farideh.Saba@NRC.GOV
Hearing Identifier: NRR_PMDA Email Number: 1821 Mail Envelope Properties (Farideh.Saba@nrc.gov20150120114300)
Subject:
Acceptance Review of St. Lucie's LAR to Adopt TSTF-505 (MF5372/73) Sent Date: 1/20/2015 11:43:46 AM Received Date: 1/20/2015 11:43:00 AM From: Saba, Farideh Created By: Farideh.Saba@nrc.gov Recipients: "eric.katzman@fpl.com" <eric.katzman@fpl.com>
Tracking Status: None "ken.frehafer@fpl.com" <ken.frehafer@fpl.com>
Tracking Status: None "Lewis, Atanya (Atanya.Lewis@fpl.com)" <Atanya.Lewis@fpl.com> Tracking Status: None
Post Office: Files Size Date & Time MESSAGE 2197 1/20/2015 11:43:00 AM Options Priority: High Return Notification: No Reply Requested: Yes Sensitivity: Normal Expiration Date: Recipients Received: