{{#Wiki_filter:12/08/ | {{#Wiki_filter:12/08/2015 12/08/2015 U.S. Nuclear Regulatory Commission operations Center Event Report P~easelPart 21 (PAR)Event # 51592Rep Org: HOWDEN NORTH AMERICA, INC. Notification Date / Time: 12/08/2015 14:31 (EST)Supplier: | ||
=teHowdenHowden North America Inc.10 CFR Part 21 Notification 7909 Parklane Road Suite 3008 December 2015 Columbia SC 29223USATel: 503 741 2700Fax: 885 757 0908Web: www.howden. | HOWDEN NORTH AMERICA, INC. Event Date / Time: 10/16/2015 (EST)Last Modification: | ||
12/08/ | 12/08/2015 Region: 1 Docket #:City: COLUMBIA Agreement State: YesCounty: License #:State: SCNRC Notified by: J TODD GUNVALSON Notifications: | ||
=teHowdenHowden North America Inc.10 CFR Part 21 Notification 7909 Parklane Road Suite 3008 December 2015 Columbia SC 29223USATel: 503 741 2700Fax: 885 757 0908Web: www.howden. | EUGENE GUTHRIE R20OHQ Ops Officer: | ||
JOHN SHOEMAKER PART 21/50.55 REACTORS EMAILEmergency Class: NON EMERGENCY 10 CFR Section:21.21 (d)(3)(i) | |||
DEFECTS AND NONCOMPLIANCE PART 21 REPORT -2 MOTORS WERE NOT PROPERLY PREPARED BEFORE SMALL STEEL SHOTBLASTINGThe following information is an excerpt from an Howden North America email:"It was discovered that two motors being prepared for steel shot blasting prior to application of the coating systemmay not have been properly sealed allowing a small amount of small steel shot blast to enter into the motor."The two motors have been repaired and returned to FPL (Florida Power and Light Company), | |||
no further action isrequired. | |||
Customer: | |||
Florida Power and Light CompanyLocation/Site: | |||
Turkey PointMotor Serial Numbers: | |||
GG153620115 and GG153620116 For questions and additional information, contact:J. Todd Gunvalson | |||
: Director, QualityHowden North America7909 Parklane RoadColumbia, SC 29223Phone 803-741-2716 Facsimile Cover SheetFrom: Howden North America, Quality FAX 866-398-1835 To: NRC Operations Center 301-816-5151 Attached: | |||
1 page10 CFR Part 21 Notification Please call 803-741-2716 if there are any transmission issues with is FAX.Sent by:a. Todd Gunvalson | |||
: Director, QualityHowden North America7909 Parklane Road Suite 300Columbia, SC 29223USAt: +1 (803) 741 2700d: +1 (803) 741 2716m: +1 (803) 420 6184f: +1 (866) 398 1835e: Todd.Gunvalson@Howden. | |||
comnw: www.howden.com Latest Blank Master Document Page 1 of 1Page 1 of I | |||
=teHowdenHowden North America Inc.10 CFR Part 21 Notification 7909 Parklane Road Suite 3008 December 2015 Columbia SC 29223USATel: 503 741 2700Fax: 885 757 0908Web: www.howden.com The below information is being provided in accordance with thereporting requirements of 10 CFR Part 21.1. Customers potentially affected: | |||
2.3.Customer Purchase Order Number Howden North AmericaControl NumberFlorida Power and Light Cornpany 02321872 A018950Part/Component Name: AC Fan Motors With Safety Related Coating SystemLocation and serial numbers of suspect motors:Customer Location/Site Motor Serial NumberFlorida Power and Light Company** | |||
Turkey Point ____GG153620115 | |||
**Florida Power and Light Comparny** | |||
Turkey Point GG153620116 | |||
**** Note: these two motors were found with this nonconformance and they have been repairedand returned to FPL, no further action required. | |||
: 4. Date nonconformance ascertained: | |||
16 October 20155. Description of potential defect/nonconformance: | |||
It was discovered that motors being preparedfor steel shot blasting prior to application of the coating system may not have been properlysealed allowing a small amount of small steel shot blast media to enter into the motor.6. Corrective actions being taken: Records, motor drawings, and photographs of all motors preparedfor blasting and coating in Medina, OH were identified, collected and examined. | |||
Quality Planningprocess was improved and controlling documents changed to add addition inspections 360degrees around the motor. As noted above the motors purchased by Florida Power and LightCompany have been corrected. | |||
The two motors identified above were the only motors that werenot properly prepared for blasting. | |||
: 7. Any advice related to the potential defect/nonconformance: | |||
None are recommended as themotors affected by this issue have been repaired and tested. The repair included replacement ofboth motor bearings. | |||
: 8. Individual completing this report:J. Todd Gunvalson | |||
: Director, QualityHowden North America7909 Parklane RoadColumbia, SC 29223Phone 803-741-2716 Howden North America Is a registered licensee of Howden Group Ltd. | |||
12/08/2015 12/08/2015 U.S. Nuclear Regulatory Commission operations Center Event Report P~easelPart 21 (PAR)Event # 51592Rep Org: HOWDEN NORTH AMERICA, INC. Notification Date / Time: 12/08/2015 14:31 (EST)Supplier: | |||
HOWDEN NORTH AMERICA, INC. Event Date / Time: 10/16/2015 (EST)Last Modification: | |||
12/08/2015 Region: 1 Docket #:City: COLUMBIA Agreement State: YesCounty: License #:State: SCNRC Notified by: J TODD GUNVALSON Notifications: | |||
EUGENE GUTHRIE R20OHQ Ops Officer: | |||
JOHN SHOEMAKER PART 21/50.55 REACTORS EMAILEmergency Class: NON EMERGENCY 10 CFR Section:21.21 (d)(3)(i) | |||
DEFECTS AND NONCOMPLIANCE PART 21 REPORT -2 MOTORS WERE NOT PROPERLY PREPARED BEFORE SMALL STEEL SHOTBLASTINGThe following information is an excerpt from an Howden North America email:"It was discovered that two motors being prepared for steel shot blasting prior to application of the coating systemmay not have been properly sealed allowing a small amount of small steel shot blast to enter into the motor."The two motors have been repaired and returned to FPL (Florida Power and Light Company), | |||
no further action isrequired. | |||
Customer: | |||
Florida Power and Light CompanyLocation/Site: | |||
Turkey PointMotor Serial Numbers: | |||
GG153620115 and GG153620116 For questions and additional information, contact:J. Todd Gunvalson | |||
: Director, QualityHowden North America7909 Parklane RoadColumbia, SC 29223Phone 803-741-2716 Facsimile Cover SheetFrom: Howden North America, Quality FAX 866-398-1835 To: NRC Operations Center 301-816-5151 Attached: | |||
1 page10 CFR Part 21 Notification Please call 803-741-2716 if there are any transmission issues with is FAX.Sent by:a. Todd Gunvalson | |||
: Director, QualityHowden North America7909 Parklane Road Suite 300Columbia, SC 29223USAt: +1 (803) 741 2700d: +1 (803) 741 2716m: +1 (803) 420 6184f: +1 (866) 398 1835e: Todd.Gunvalson@Howden. | |||
comnw: www.howden.com Latest Blank Master Document Page 1 of 1Page 1 of I | |||
=teHowdenHowden North America Inc.10 CFR Part 21 Notification 7909 Parklane Road Suite 3008 December 2015 Columbia SC 29223USATel: 503 741 2700Fax: 885 757 0908Web: www.howden.com The below information is being provided in accordance with thereporting requirements of 10 CFR Part 21.1. Customers potentially affected: | |||
2.3.Customer Purchase Order Number Howden North AmericaControl NumberFlorida Power and Light Cornpany 02321872 A018950Part/Component Name: AC Fan Motors With Safety Related Coating SystemLocation and serial numbers of suspect motors:Customer Location/Site Motor Serial NumberFlorida Power and Light Company** | |||
Turkey Point ____GG153620115 | |||
**Florida Power and Light Comparny** | |||
Turkey Point GG153620116 | |||
**** Note: these two motors were found with this nonconformance and they have been repairedand returned to FPL, no further action required. | |||
: 4. Date nonconformance ascertained: | |||
16 October 20155. Description of potential defect/nonconformance: | |||
It was discovered that motors being preparedfor steel shot blasting prior to application of the coating system may not have been properlysealed allowing a small amount of small steel shot blast media to enter into the motor.6. Corrective actions being taken: Records, motor drawings, and photographs of all motors preparedfor blasting and coating in Medina, OH were identified, collected and examined. | |||
Quality Planningprocess was improved and controlling documents changed to add addition inspections 360degrees around the motor. As noted above the motors purchased by Florida Power and LightCompany have been corrected. | |||
The two motors identified above were the only motors that werenot properly prepared for blasting. | |||
: 7. Any advice related to the potential defect/nonconformance: | |||
None are recommended as themotors affected by this issue have been repaired and tested. The repair included replacement ofboth motor bearings. | |||
: 8. Individual completing this report:J. Todd Gunvalson | |||
: Director, QualityHowden North America7909 Parklane RoadColumbia, SC 29223Phone 803-741-2716 Howden North America Is a registered licensee of Howden Group Ltd.}} |
Revision as of 16:04, 30 June 2018
ML15345A390 | |
Person / Time | |
---|---|
Site: | Turkey Point |
Issue date: | 12/08/2015 |
From: | Gunvalson J T Howden North America |
To: | Office of Nuclear Reactor Regulation |
References | |
51592 | |
Download: ML15345A390 (3) | |
Text
12/08/2015 12/08/2015 U.S. Nuclear Regulatory Commission operations Center Event Report P~easelPart 21 (PAR)Event # 51592Rep Org: HOWDEN NORTH AMERICA, INC. Notification Date / Time: 12/08/2015 14:31 (EST)Supplier:
HOWDEN NORTH AMERICA, INC. Event Date / Time: 10/16/2015 (EST)Last Modification:
12/08/2015 Region: 1 Docket #:City: COLUMBIA Agreement State: YesCounty: License #:State: SCNRC Notified by: J TODD GUNVALSON Notifications:
EUGENE GUTHRIE R20OHQ Ops Officer:
JOHN SHOEMAKER PART 21/50.55 REACTORS EMAILEmergency Class: NON EMERGENCY 10 CFR Section:21.21 (d)(3)(i)
DEFECTS AND NONCOMPLIANCE PART 21 REPORT -2 MOTORS WERE NOT PROPERLY PREPARED BEFORE SMALL STEEL SHOTBLASTINGThe following information is an excerpt from an Howden North America email:"It was discovered that two motors being prepared for steel shot blasting prior to application of the coating systemmay not have been properly sealed allowing a small amount of small steel shot blast to enter into the motor."The two motors have been repaired and returned to FPL (Florida Power and Light Company),
no further action isrequired.
Customer:
Florida Power and Light CompanyLocation/Site:
Turkey PointMotor Serial Numbers:
GG153620115 and GG153620116 For questions and additional information, contact:J. Todd Gunvalson
- Director, QualityHowden North America7909 Parklane RoadColumbia, SC 29223Phone 803-741-2716 Facsimile Cover SheetFrom: Howden North America, Quality FAX 866-398-1835 To: NRC Operations Center 301-816-5151 Attached:
1 page10 CFR Part 21 Notification Please call 803-741-2716 if there are any transmission issues with is FAX.Sent by:a. Todd Gunvalson
- Director, QualityHowden North America7909 Parklane Road Suite 300Columbia, SC 29223USAt: +1 (803) 741 2700d: +1 (803) 741 2716m: +1 (803) 420 6184f: +1 (866) 398 1835e: Todd.Gunvalson@Howden.
comnw: www.howden.com Latest Blank Master Document Page 1 of 1Page 1 of I
=teHowdenHowden North America Inc.10 CFR Part 21 Notification 7909 Parklane Road Suite 3008 December 2015 Columbia SC 29223USATel: 503 741 2700Fax: 885 757 0908Web: www.howden.com The below information is being provided in accordance with thereporting requirements of 10 CFR Part 21.1. Customers potentially affected:
2.3.Customer Purchase Order Number Howden North AmericaControl NumberFlorida Power and Light Cornpany 02321872 A018950Part/Component Name: AC Fan Motors With Safety Related Coating SystemLocation and serial numbers of suspect motors:Customer Location/Site Motor Serial NumberFlorida Power and Light Company**
Turkey Point ____GG153620115
- Florida Power and Light Comparny**
Turkey Point GG153620116
- Note: these two motors were found with this nonconformance and they have been repairedand returned to FPL, no further action required.
- 4. Date nonconformance ascertained:
16 October 20155. Description of potential defect/nonconformance:
It was discovered that motors being preparedfor steel shot blasting prior to application of the coating system may not have been properlysealed allowing a small amount of small steel shot blast media to enter into the motor.6. Corrective actions being taken: Records, motor drawings, and photographs of all motors preparedfor blasting and coating in Medina, OH were identified, collected and examined.
Quality Planningprocess was improved and controlling documents changed to add addition inspections 360degrees around the motor. As noted above the motors purchased by Florida Power and LightCompany have been corrected.
The two motors identified above were the only motors that werenot properly prepared for blasting.
- 7. Any advice related to the potential defect/nonconformance:
None are recommended as themotors affected by this issue have been repaired and tested. The repair included replacement ofboth motor bearings.
- 8. Individual completing this report:J. Todd Gunvalson
- Director, QualityHowden North America7909 Parklane RoadColumbia, SC 29223Phone 803-741-2716 Howden North America Is a registered licensee of Howden Group Ltd.
12/08/2015 12/08/2015 U.S. Nuclear Regulatory Commission operations Center Event Report P~easelPart 21 (PAR)Event # 51592Rep Org: HOWDEN NORTH AMERICA, INC. Notification Date / Time: 12/08/2015 14:31 (EST)Supplier:
HOWDEN NORTH AMERICA, INC. Event Date / Time: 10/16/2015 (EST)Last Modification:
12/08/2015 Region: 1 Docket #:City: COLUMBIA Agreement State: YesCounty: License #:State: SCNRC Notified by: J TODD GUNVALSON Notifications:
EUGENE GUTHRIE R20OHQ Ops Officer:
JOHN SHOEMAKER PART 21/50.55 REACTORS EMAILEmergency Class: NON EMERGENCY 10 CFR Section:21.21 (d)(3)(i)
DEFECTS AND NONCOMPLIANCE PART 21 REPORT -2 MOTORS WERE NOT PROPERLY PREPARED BEFORE SMALL STEEL SHOTBLASTINGThe following information is an excerpt from an Howden North America email:"It was discovered that two motors being prepared for steel shot blasting prior to application of the coating systemmay not have been properly sealed allowing a small amount of small steel shot blast to enter into the motor."The two motors have been repaired and returned to FPL (Florida Power and Light Company),
no further action isrequired.
Customer:
Florida Power and Light CompanyLocation/Site:
Turkey PointMotor Serial Numbers:
GG153620115 and GG153620116 For questions and additional information, contact:J. Todd Gunvalson
- Director, QualityHowden North America7909 Parklane RoadColumbia, SC 29223Phone 803-741-2716 Facsimile Cover SheetFrom: Howden North America, Quality FAX 866-398-1835 To: NRC Operations Center 301-816-5151 Attached:
1 page10 CFR Part 21 Notification Please call 803-741-2716 if there are any transmission issues with is FAX.Sent by:a. Todd Gunvalson
- Director, QualityHowden North America7909 Parklane Road Suite 300Columbia, SC 29223USAt: +1 (803) 741 2700d: +1 (803) 741 2716m: +1 (803) 420 6184f: +1 (866) 398 1835e: Todd.Gunvalson@Howden.
comnw: www.howden.com Latest Blank Master Document Page 1 of 1Page 1 of I
=teHowdenHowden North America Inc.10 CFR Part 21 Notification 7909 Parklane Road Suite 3008 December 2015 Columbia SC 29223USATel: 503 741 2700Fax: 885 757 0908Web: www.howden.com The below information is being provided in accordance with thereporting requirements of 10 CFR Part 21.1. Customers potentially affected:
2.3.Customer Purchase Order Number Howden North AmericaControl NumberFlorida Power and Light Cornpany 02321872 A018950Part/Component Name: AC Fan Motors With Safety Related Coating SystemLocation and serial numbers of suspect motors:Customer Location/Site Motor Serial NumberFlorida Power and Light Company**
Turkey Point ____GG153620115
- Florida Power and Light Comparny**
Turkey Point GG153620116
- Note: these two motors were found with this nonconformance and they have been repairedand returned to FPL, no further action required.
- 4. Date nonconformance ascertained:
16 October 20155. Description of potential defect/nonconformance:
It was discovered that motors being preparedfor steel shot blasting prior to application of the coating system may not have been properlysealed allowing a small amount of small steel shot blast media to enter into the motor.6. Corrective actions being taken: Records, motor drawings, and photographs of all motors preparedfor blasting and coating in Medina, OH were identified, collected and examined.
Quality Planningprocess was improved and controlling documents changed to add addition inspections 360degrees around the motor. As noted above the motors purchased by Florida Power and LightCompany have been corrected.
The two motors identified above were the only motors that werenot properly prepared for blasting.
- 7. Any advice related to the potential defect/nonconformance:
None are recommended as themotors affected by this issue have been repaired and tested. The repair included replacement ofboth motor bearings.
- 8. Individual completing this report:J. Todd Gunvalson
- Director, QualityHowden North America7909 Parklane RoadColumbia, SC 29223Phone 803-741-2716 Howden North America Is a registered licensee of Howden Group Ltd.