CCMANCHE PEAK RESPONSE TEAM | . a.u-. | ||
:n -. | |||
w.< | |||
i CCMANCHE PEAK RESPONSE TEAM | |||
?OPULATION ITEMS LIST Page 1 of 1 POPULATION NAME: | |||
Fuel Pool Liner DATE: September 27, 1985 RESPONSI3LE QA/QC YUPPORT ENGINEER POPULATIONS LIST SOURCE: | |||
The following Engineering Drawings were used to develop the population items to perform the reinspection of the Fuel Pool Liners: | The following Engineering Drawings were used to develop the population items to perform the reinspection of the Fuel Pool Liners: | ||
2323-S-0831, Sheet 1 - Fuel pool liner details 2323-5-0832, Sheet 2 - Fuel pool liner details 2323-S-0833, Sheet 3 - Fuel pool liner details 2323-S-0834, Sheet 4 - Fuel pool liner details BASIS FOR ACCEPTING THE LIST: | 2323-S-0831, Sheet 1 - Fuel pool liner details 2323-5-0832, Sheet 2 - Fuel pool liner details 2323-S-0833, Sheet 3 - Fuel pool liner details 2323-S-0834, Sheet 4 - Fuel pool liner details BASIS FOR ACCEPTING THE LIST: | ||
Fuel pool liner population consist of welds for the stainless steel plates, | Fuel pool liner population consist of welds for the stainless steel plates, embeds and angles. The veld sears on the waterside of the fuel pool are accessible. A list of all welds was prepared from the traveler packages of welds. The list was then compared with the contractors drawings. In a few instances it was noted that the welds shown on the drawings were not on the | ||
! traveler list and vice versa. Weld numbers 37 & 39 were shown on the | |||
! drawings as drain welds and the travelers for these two welds were not found. Welds shown in the traveler packages with a prefix "A" or suffix "A" were not found on the drawing. However, a count of the welds on the drawing shows a total of 2371 welds, where as a count of the welds in traveler packages indicate 2610 welds. | |||
The later figure is accepted as more accurate, because a traveler package was made for each weld as the work progressed. The last update of the i | |||
The later figure is accepted as more accurate, because a traveler package | drawings een done in April 1983. The two welds 37 & 39, for which the traveler packages were not found, are for the drains and they are used for test connections. These welds are not accessible and will not affect the samples. A random sample of accessible welds conforming to the population description will be selected from the weld traveler package identifications. | ||
was made for each weld as the work progressed. The last update of the drawings | |||
test connections. These welds are not accessible and will not affect the samples. A random sample of accessible welds conforming to the population description will be selected from the weld traveler package identifications. | |||
BASIS FOR ACCEPTING ANY ADDITIONAL ITEMS: | BASIS FOR ACCEPTING ANY ADDITIONAL ITEMS: | ||
None 8606230355 860609 PDR | None 8606230355 860609 PDR FOIA GARDE 86-36 PDR 3 | ||
APPROVED BY: | |||
f*fjr,-M. | |||
0194 POPDE3}} | DATE: | ||
9/18/85 em QA/QC LEAD DISCIPLINE ENGINEER APPROVED SY: [#M b / | |||
/ | |||
DATE: j | |||
^ | |||
QA/QC REINSPECTION ENGINEERING SUPERVISOR C ? ? | |||
.'0 3. 2 A. ?.av;stan ) | |||
0194 POPDE3 | |||
-}} | |||
Latest revision as of 07:55, 10 December 2024
| ML20199E657 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 09/27/1985 |
| From: | Brown R, Patterson A NRC - COMANCHE PEAK PROJECT (TECHNICAL REVIEW TEAM) |
| To: | |
| Shared Package | |
| ML20199D912 | List:
|
| References | |
| FOIA-86-36 PP-850927, NUDOCS 8606230355 | |
| Download: ML20199E657 (1) | |
Text
m=
m
. a.u-.
- n -.
w.<
i CCMANCHE PEAK RESPONSE TEAM
?OPULATION ITEMS LIST Page 1 of 1 POPULATION NAME:
Fuel Pool Liner DATE: September 27, 1985 RESPONSI3LE QA/QC YUPPORT ENGINEER POPULATIONS LIST SOURCE:
The following Engineering Drawings were used to develop the population items to perform the reinspection of the Fuel Pool Liners:
2323-S-0831, Sheet 1 - Fuel pool liner details 2323-5-0832, Sheet 2 - Fuel pool liner details 2323-S-0833, Sheet 3 - Fuel pool liner details 2323-S-0834, Sheet 4 - Fuel pool liner details BASIS FOR ACCEPTING THE LIST:
Fuel pool liner population consist of welds for the stainless steel plates, embeds and angles. The veld sears on the waterside of the fuel pool are accessible. A list of all welds was prepared from the traveler packages of welds. The list was then compared with the contractors drawings. In a few instances it was noted that the welds shown on the drawings were not on the
! traveler list and vice versa. Weld numbers 37 & 39 were shown on the
! drawings as drain welds and the travelers for these two welds were not found. Welds shown in the traveler packages with a prefix "A" or suffix "A" were not found on the drawing. However, a count of the welds on the drawing shows a total of 2371 welds, where as a count of the welds in traveler packages indicate 2610 welds.
The later figure is accepted as more accurate, because a traveler package was made for each weld as the work progressed. The last update of the i
drawings een done in April 1983. The two welds 37 & 39, for which the traveler packages were not found, are for the drains and they are used for test connections. These welds are not accessible and will not affect the samples. A random sample of accessible welds conforming to the population description will be selected from the weld traveler package identifications.
BASIS FOR ACCEPTING ANY ADDITIONAL ITEMS:
None 8606230355 860609 PDR FOIA GARDE 86-36 PDR 3
APPROVED BY:
f*fjr,-M.
DATE:
9/18/85 em QA/QC LEAD DISCIPLINE ENGINEER APPROVED SY: [#M b /
/
DATE: j
^
QA/QC REINSPECTION ENGINEERING SUPERVISOR C ? ?
.'0 3. 2 A. ?.av;stan )