ML20199E349

From kanterella
Jump to navigation Jump to search
Rev 1 to Instruction QI-008, Reinspection of Conduit/Ie Conduit
ML20199E349
Person / Time
Site: Comanche Peak  
Issue date: 07/25/1985
From: Farino E, Hansel J, Patterson A
EVALUATION RESEARCH CORP.
To:
Shared Package
ML20199D912 List: ... further results
References
FOIA-86-36 QI-008, QI-8, NUDOCS 8606230275
Download: ML20199E349 (20)


Text

f'

  • '3 Pcg2 1 ef 10 e

j

,,p 4,

u-i

  • 4 EVALUATION RESEARCH CORPORATION ~

j- ;

COMANCHE PEAK RESPONSE TEAM QUALITY INSTRUCTION FOR ISSUE SPECIFIC ACTION PLAN VII.c INSTRUCTION NO.: QI-003 I

REVISION:

1 Q\\

EF CTIVE DATE: 07/26/85

/

REINSPECTION OF CONDUIT /I-E-CDUT s

{

Prepared by:

/Y/

O Date:

7*86-8/l Approved by: ::hf/$&.W)fbfw Date:

7/2s~/PS" Issue Coopitator 7/2b/

Approved by:

Date:

On dite QA Representative Approval by:

Date:

71.1 83~

QC Review Team Leader I

I 8606230275 860609 PDR FOIA GARDE 86-36 PDR

.l, ',jl ',,}

f' QI-008 Rsv. I s

r Reinspection of Conduit /I-E-CDUT 1.0 PURPOSE To provide methods to be used and the accept / reject criteria to be applied when performing reinspection of conduit.

2.0 APPLICABILITY This procedure applies to reinspection of samples selected from the conduit population.

The population is described in the Population Description for Conduit.

3.0 REFERENCES

3.1 CPP-009, Performance of Reinspection and Documentation Reviews l

3.2 2323-El(E2)-1700," Cable and Raceway Schedule 3.3 2323-El(E2)-1800, Material List 3.4 2323-S-0910, Conduit Support Package 4.0 GENERAL Reinspection reviews are performed and documented in accordance with established project procedures and instructions.

This instruction establishes the attributes and accept / reject criteria for reinspections of conduit.

Reference 3.1 addresses the method to perform reinspections, document and process the results.

5.0 PROCEDURE 5.1 Using the information in Reference 3.1 and below, perform the reinspections on the items in this population and document the resulto of the reinspection on the checklist (Attachment 6.9).

1.

Size and Material

a. Verify that installed conduit size agrees with size as called for on the conduit layout drawings. Conduit of the next larger size in accordance with the following j

size range is not considered a deviation from the designed size conduit size range ( 1/2, 3/4, 1, 1-1/2, 2.'3, 4, 5).

4 4

/

A.".}

1 s

QI-008 R2v. 1 6

b. Verify that conduit material used is rigid steel, sinc I

coated unless otherwise noted on drawings.

2.

Identification

a. Verify that the exposed conduit, except lighting conduit, has permanent identification markings (alphanumeric code designation) and that the identification agrees with the cable and raceway schedule report. Report Section No. 70, 2323-El-1700 and 2323-E2-1700 including outstanding DCA's.

Markings may be any of the following:

  • Freehand markings with black ink marker or paint
  • Adhesive markers factory pre-printed (except reactor containment, and manholes)
  • Metal or plastic tags Metal tags used inside the Reactor Containment must be attached to the conduit with either re Tefsel

)

ty-raps, or engineered approved faste gs.

b. Verify, except for lighting conduit, that permanent identification markings have been applied at the following locations;
  • At both ends of each run
  • Entering or leaving a junction / pull box each side j
  • Entering or leaving a tray
  • On each side of a floor or wall NOTE:

Conduit 10 feet in length or less need only l

be identified at a single point in the run.

1 A single conduit entering and leaving a pull box is not required to be identified on either side of the box.

.... % M *-

c. Verify that color code markings have been applied at intervals not to exceed 15 feet.

i For conduit identification and color code explanations l

see Attachment 6.1.

l NOTE:

For cable tray identification explanation see j.2.

3.

Origin and Destination i

/

Verify that the conduit origin and destination agree with the initial point and ending point designation per the Cable and Raceway Schedule Report No. 70 (conduit list),

[

2323-El-1700, and 2323-E2-1700, including all approved outstanding design change authorization (DCAs).

,.e k

[,

,ea p

k5 3

1

(.

QI-008 3

Rev. I V

4.

Fittings r

s. Verify that either an insulated bushing or sleeve insert has been installed on all conduit ends including conduit terminating at equipment / cabinets, junction /

pull boxes, except for conduit connections to equipment with hubs.

b. Verify that conduit terminating at either a junction / pull box or cabinet is fastened with a locknut or bushing to the enclosure,
c. Verify that couplings are secure (i.e., couplings are not loose).
d. Conduit connections at outdoor enclosures containing terminations, or indoors where exposed to continuous wetting shall be made with liquid tight hub fittings.

Fitting type shall be as specified on the Material list. Casketed lo.cknuts are an acceptable substitute.

Conduits entering the top of equipment subject to water spray from fire protection sprinkler activation should be sealed according to details provided on the drawings.

5.,

Expansion Fittings Verify that either expansion fitting or flexible conduit has been used in long straight runs of conduit. Long straight runs (bends less than 15* are considered straight for this application only) of continuous conduit shall be

~

provided with either an expansion fitting or flexible conduit at 75-foot intervals.

6.

Bends N.I.S. conduit raceway, function 6R, 6W, 6B and 6Y (for third and fourth character respectively in the conduit identification number) field bends shall comply with the follos*ing dimensions:

l Size of Conduit Minimum Band Radius 3" diameter conduit -

15" min. bend radius 4" diameter conduit - 20" min. bend radius 7.

Total Conduit Length and Bends Between Pull Points i

N.I.S. conduit raceway functions 6R, 6W, 68.and 6Y are to be installed to the dimension provided on the drawings with a maximum tolerance of 26 inches from the design l

dimension. The distance between junction boxes / pull points and the length of conduit between boxes / pull points shall be in accordance with the dimensions provided on the drawings.

e J

., )

,u(

i 4

_,-. ~

,___m._ _,. - - -, _,.

QI-008 Rsv. 1 g

Where design dimensions are not provided on drawings, verify the installation of N.I.S. conduit in accordance with the following requirementer 3

Pull boxes are to be located at intervals defined by A

+ B = 100, where "A" is the total number of degrees of conduit bends between pull points and "B" is the total number of running feet between pull points.

8.

Flexible Conduit

a. Verify that conduit connections made to motors and free standing equipment is made with flexible conduit.

Conduit connections to wall mounted equipment, where the equipment is supported on the same surface as the conduit, may be either rigid or flexible.

b. Verify length of flexible conduit in accordance with the following:

Motors and other freestanding equipment Size of Conduit Maximum Length 1/2" to 3" conduit - 48" maximum length 4" to 5" conduit

- 60" maximum length g.

1 Unless otherwise specified in S-0910, the minia'im flexible conduit length is 18 inches for flexfble conduit greater than 2 inches in diameter.

For flexible conduit 2 inches in diameter or smaller, the minimum length is that which allows a minimum of 1 inch plack movement of the flexible conduit.

Flexible lengths shall be in accordance with the above, unless otherwise shown on the drawings.

c. Verify that flexible conduit has been used for continuous runs of conduit across shake spaces between adjacent buildings. Verify 1" movement (slacki has been provided.

Shake space requirements are applicable for continuous runs of conduit between the safeguard building or fuel building and auxiliary building.

d. Verify that stainless steel flexible conduit is used in containment.
9. Conduit and Cable Tray Interface
a. Where conduit attaches to a cable tray verify that the connection is made with flexible conduit.

r

}

. C&

' 4;;

[*

' 6

%.l.,Q

~

,a

~.q

L.

s.

QI-008 R v. 1 I

b. Where conduit interfaces with a cable tray verify that the conduit terminates at the tray in accordance with

,.3 detail 23.

10. Clearance
a. Conduit shall not be installed closer than 6 inches from the insulation of hig'h temperature Class I and II piping except as necessary for pipe-mounted instrumentation such as thermocouples. Where this distance has not been maintained verify that heat reflective shielding has been installed as shown on the drawings.

In no case shall any part of the conduit or the conduit support system come in direct contact with uninsulated equipment in the piping system or with pipe restraints or anchors.

NOTE:

1.

Class I or Class II piping can be identified by the mechanical I.D. Tags.

Typical spool piece tag number:

3"-SB-1-63-301-5 (Last numeral is Class.)

If tag cannot be seen, go to pipe support typical tag number: SFX-022-700-A55D (Last numeral is Class.) Support will be the same Class as pipe it supports.

2.

High temperature pipe is pipe that has an operating temperature of 200*F or more.

For temperature ratings of piping reference the Pipe Line Designation Table.

~

b. Minimum clearance between conduits containing power cables (raceway function 19, 20, IG, 2G, IK, 2K and SK) shall not be less than outside diameter of larger conduit except as defined below:

\\

1.

At such points where exposed conduits enter or exit any equipment or box to a point of 4'-0" from se:h equipment or box, but not less than 1-inch between different train conduit.

2.

In general plant areas where conduits have a minimum clearance of 1/4 0.D. of the larger conduit, but not less than 1" between different train conduits, for conduit runs not exceeding 10 feet in length.

/

,)4'

QL e

p 6

l'1 7: c c-..-

I 4

QI-008 Rav. 1

11. Fire Stops and Seals
a. Conduit connections to floor mounted equipment and conduit penetrating a floor or fire rated wall.

1.

Verify that where a conduit penetrates a fire wall or floor either a "C" condulet, EYS fitting, or junction / pull box has been installed between the equipment and the fire wall.

Verify by visual inspection t# t sealing material has been s

installed. /Where the conduit penetrates a floor orh y re rate wall without connection to equipment,

/

verify that a sealing material has been installed.

2.

Verify by visual inspection at equipment with stub-ups(stove pipes) sealing material has been installed.

b. Conduit connections to other nonfloor mounted totally enclosed. equipment.

1.

Where a conduit penetrates either a fire wall or floor and the distance from the wall to the g ent is less than 10 feet on either side of

}

the wall or floor, verify the installation' of condulet, EYS or pull / junction box including

(

visual verification for the installation of sealing material per a.1 above.

2.

Where a conduit penetrates either a fire wall or floor and the length of conduit from the 9

wall to the equipment is 10 feet or greater in length on both sides of the wall or floor the installation of C condulet, EYS fitting, or y

pull / junction box is not required between the fire

(

wall / floor and the equipment.

I NOTE: DBD-SY1 FHA drawings show location of fire rated floors and walls.

12. Separation i
a. For all conduits except N.I.S. conduit raceway function 6R, 6W, 6B, and 6Y, verify separation as follows:

1.

Minimum separation between conduits having different trains and/or channels including Train A

& B lighting conduit shall be'one inch.

Attachneut 6.4 lists the trains and channels and i

their associated raceway functions (third and fourth characters of conduit ID number).

s.

a

.., inml.i'll

~~

7

-e

,,-,-----_w

--,,,--,.,-,,.r,..,,.,,--.,.,.,_--n,_.-.,,-.,.._,-,.,n

.. - - -..,.. - - - _. -., - - -. - -., - - - -,, ~., - -., - ~, -..,

..,n.

QI-008 Rsv. 1 2.

A minimum separation of 2'-0" must be maintained

(-

.between parallel runs of conduit raceway Systems 29, 2G, and 2K; 39, 3G, and 3K; 5R, SW, 5B and 5Y; 5K and NIS conduit raceway functions 6R, 6W, 65 and 05 6Y except as noted.

g pf'O'

b. Separation between N.I.S. conduit and other conduit to be as follows:

1.

A minimum separation of 2'-0" must be maintained N[

between parallel runs of "NIS" conduit systems NN y\\

(Raceway functions 6R, 6W, 6B and 6Y) and different e

channel "NIS" Conduit.

2.

A minimum separation of 2'-0" must be maintained

'oetween parallel runs of "N.I.S." conduit raceway functions 6R, 6W, 6B, 6Y and raceway systems 26, 2G

& 2K; 39, 3G & 3K; 5R. SW, SB & 5Y; SK; & 6K.

NOTE:

Minimum separation of non-parallel runs of "NIS" conduit and the above mentioned systems (i.e., crossing each other at an angle greater than 15 degrees) is 1-inch.

c. Verify separation between conduit (including lighting Train A or B conduit) and cable tray except N.I.S.

(

system per the following:

1.

Minimum vertical separation between a Train A, B, non N.I.S. channels I, II, III, & IV conduit and the' top of an open tray having different train or channel shall be 2'-0" in the cable spreading room and 3'-0" in general plant areas. The minimum separation is 1-inch where a solid cover is provided.

See Attachment 6.5.

2.

Minimum separation between a Train A, B, non N.I.S.

channels I, II, III, & IV conduit and either the bottom or side of a cable tray having different train or channel rhall be 1".

See Attachment 6.6.

3.

Minimum separation betwe-, a Train C conduit and either the bottom, top or side of a tray having different train or channel designation shall be 1".

See Attachment 6.6, detail 49.

NOTE:

1.

All bus duct shall be treated the same as non-safety (Train "C") ladder tray.

2.

All non-scheduled raceway (security, fire detection, non train lighting, communi-cations, etc.) shall be treated as non-safety (Train "C").

3 f

y

'e A

D g

8

.x

QI-008 R;v. 1 4.

C, Verify separation for all conduit except N.I.S.

system conduit passing a vertical tray per

-.8.

)

d. Verify N.I.S. conduit to cable tray separation as follows:

1.

A minimum separation of 6'-0" must be maintained between "NIS" conduit systems,(Raceway functions 6R, 6W 68 & 6Y) & 6.9Kv raceway functions 19, IG &

IK including cable bus duct. See Attachment 6.7.

2.

A minimum separation of 2'-0" must be maintained between parallel runs "NIS" conduit (Raceway functions 6R, 6W 65 & 6Y) and cable tray raceway system 29, 2G & 2K; 39, 3G & 3K; 5R, 5W, 58 & 5Y; 5K; & 6K.

Minimum separation of non-parallel runs of "NIS" conduit and the above mentioned systems (i.e., crossing each other at an angle greater than 15 degrees) reduce such separation to 1" with the addition of tray covers. (Top only required for N.I.S. conduit passing over the top, and bottom only required for N.I.S. conduit passing on the bottom.

Solid bottom tray constitutes as a cover.)

e. Verify separation between conduit and exposed cable

(.

(i.e., cable not enclosed in a raceway) per the following:

1.

Separation between train or channel conduit except N.I.S. system and other exposed train or channel cable shall be as follows:

  • 3'-0" in general plant areas
  • l'-0" in cable spreading area The 1 foot - 3 foot dimension may be reduced provided either conduit or cable has a separation barrier material (SBM) blanket applied for a distance to provide required separation for the area. See Attachment'6.7, detail 57.

2.

Separation between N.I.S. system conduit and exposed cable shall be as follows:

a.

A minimum separation of 6'-0" must be maintained between N.I.S. conduit and exposed power cables (raceway functions 19, IG & IK).

a WI' s

h

QI-008 Rev. 1 I.-

b.

A minimum separation of 2'-0" must be maintained between parallel runs of N.I.S.

. conduit and exposed cable (raceway functions 29, 2G, 2K; 39, 3G & 3K; 5R, 5W. 5B & 5Y; &

6K).

5.2 Document the results of the reinspection on the attributed checklist (Attachment 6.9).

Forms are available in Records Management.

6.0 ATTACHMENTS 6.1 Conduit Identification 6.2 Cable Tray Identification 6.3 Conduit / Cable Tray Interfaces 6.4 Trains and Channels and Associated Raceways 6.5 Separation Requ'irements 6.6 Separation Requirements 6.7 Separation Requirements I

6.8 Separation Requirements 6.9 Check 11st oe

/

1 2

10 s!

/s*,

'.,;<,y,'

'; l $,

s

9, Attcchment 6el 3jj QI-008

~..

Rev. 1

-7 Page 1 of 1

{j

.?,

i o

~;

3dIILL *'* 8' *"3 J E E 1 (s.e.ty astmed Te.a.)

e - an==== es sets ensee sa Treie e.

ere Aseestated "4" Trots = Gre.ge with white certpos S

  • 3" Trata = Stees a

=

I

  • Shot I assestated "B" Trata = Seees with white ottipee E = (see-4)

"C" Trais Slash

=

imu e,~~>

m. -1,

,e.

1:: = : 's,".e' fi... e - un.u.,

=a-

-t a

..... - lit=.

a,s.o.,e a-

-> in

. ::at.,".e:'.,.

le ie-T

- > =

.t.

t.

mer t.t.

. i.ool..

1.

{

3e. M. 3a. esev 4.c 6 amery reser poedere undee ease Gase! Coetrol) assieter Proteetles lastrumsetectee St. SW. SS. 31 latN stemet ed. 4C. M = Coetrol AC & BC & 8ms11 Power Feedere taeet 48ev (Lesal Coetre!)

M. 4W. 64, ei Butleet teetrimeetettee Systee tee Levet signale (Leest Coetret)

79. 78. FE

=

Telephaes & Commusmaaottene K

A typical conduit identification number is depicted as follows:

i-

.C. 1. 4..R. 16397 Denotes l

Conduit Unique conduit number I

Designates Unit 1 i

Designates circuit train or Designates channel. Refer to Table 3 raceway function above.

Refer to Table 2 above.

94 es m_

se e

s. v e r6 4 9 e s
  • ye

/

[Ie

' I'*1, e ', Q

. _ _ _ _ _, _ _ _ _ _. ~.

Act:chment 6.2

' 2 QI-008 Rev. 1 3

~

Page 1 of 1 j

(

f.

I

?

TRAY U SER (IPt.AMATION T_ _i_ _2 _d__S_.D_ A._ _R_

End Point Desionator Letter "T* Designates Tray Unit Mumber (See Table #1)

Alpha Oestonator AA.ZZ w

Area Code (See Table #2)

Voltace & Seoaration 65ee Table # 4)

TA8tE 1 TABLE 1 TABLE 2 0 - Common A - Auxiliary 9 - Orange - A Train 1 - Unit 1 C - Electrical & Control G - Green - 8 Train 2 - Unit 2 0 - Diesel K - Stack - C Train E - Electrical Equipment Area ( in Safeguard)

A - Red

- Channel 1 F - Fuel W - White - Channel !!

M - Miscellaneous Buildings 8 - 81ue

- Channel !!!

V - Yellow - Channel IV R - Reactor 5 - Safeguard T - Turbine & Switchgear TABLE 4(B5tewayFumettee) 4.9 EV A.C.

If, 10, IE 26, 24. 2E - eso vec.120, 20e vec - 12SV-250V D.C. power Centrol AC & DC & Smell Fever Feeders 30, 3C. 3E teder ea0V 1mv Level $13 eels 44, 44, et Beester Protecties feetrussetaties i

4a. 4W. 48. 4T i

Imv Level Signale

'4a0V AC & Beavy Power Feedere Under 480V Se. SC. SE (Lesel Centre 1) i Beester f.etuttee toetrussestattee Sa. SU. 58. ST 12eV sisi41 Coetrol AC & 3C & Ses11 Power Feeders ed, 64. 4E I

Weder 40eV (Leeel Coetrol) maeleet teatrumentation Systee es. 4W. 68. of t

tav Level signale (Leest Centre 1)

N. M. FE

=

Telepheme & Commsessatises E

e WIIISO O &

o

. en

. en j

e

~

/l:

.yg;p

% O

Attcchment 6.3 i

QI-008 Rev. 1 3

Page 1 of 1

}

(

e i

1

.p'a:" *""",.' ar.a,t',r.,W.

.a. aar -

re.

.e,rea 4 --

'f,f.e."J."4,,e u==.a =====

st gy f.e..

.r..-

.sure, g ru,-

. y-,-

~~

s-x r..,4,,..,

a. -

s

...,.u.

a.

.1,-.--

e

.,...e o...

3 n

1

,s.s e e.e

..e..

..,-.e.

e

. sos d

i

',;l

('L 1.~.:::.

- = -

, i.

ggme f

\\\\

  1. d r

mu.o

.,g e.e e..s.s.so.ee f

.m =,eu.e.e ws. e g a,s.e,r.s,e.

w

{,,

.m.

s v e

.,,,,.i, DETAli 256.

[

e.e.sv., e. sa.s se.sv.f*

se c.L.r.s.,e. s.es e.e..rr

,s

,t..,ue.o,' cev,.?

e

,,r u

ee ev

.su.. s

6. ee use..a a.ea meev..

DETAll RS A r,s.s.6 use I,,pe.

, e.s.e o., are.e.4. 4 6s s e.. fee, gL 3.,

I l.-::aC p-(

g-..-

m W

~-

',..a..n.

t;'s.=. H. e

'X.'

n w

.-u ens..

e e,.go s.o

, J s.e m.ees e.s.e pe e f.e a e

sar....e sactieu ruirw-sneriou rua.rus-L_.. T r

d smas b'4r 9..L....

a-

.- mu

.. a sectiou rsee.rsei-sacTiou rser rsez-

...a

,e w u

o gy,a,s..o.,,;.tg;/g g yg n,.' y,;:g

...<n er w i

.u r u u.

DETAll 23 v.v e.. 6.<.,...,,,,so.,......,.r..

...me

....e.

r...

MD 8

9

, 3 7*

b. %.,.,

,s

,u

'f

Attcchment 6.4 QI-008 Rev. 1

(

Page 1 of 1 l(

  • 1 DWG Train or Class Symbol Channel Raceway Function d

Train "A" 19,29,30,49 IE" IE Associated" IE" Train "B" 1G, 2G, 3G, 4G IE Associated" Non "lE" NONE Train "C" IK,2K,3K,1,K,5K,6K IE" Channel I 4R, SR lE" Channel II 4W, SW IE" Channel III 4B, SB IE" Channel IV 4Y, 5Y p

Sue

'h

't.**

I;

,g

Attcchment 6.5 i

QI-008-Reve 1 Page 1 of 1 saganaTras sanges age -

t-g.'.

c osza corsa a

ee g

a come:T I.

I A I r TRAY arcatass a

sos. s m y 4

l l

l Tuzs storasses as

3. ass TaAma 5

g TRAIN & T5ht, (a) 3'ge la general E'

==== en

  • 2=as ar l

m a sortcN (M 3ege 14 Cele -

i a

sprendaag aree i

sterrow.a.

(*}$"Hd'aers t

.d..

(nse.f*'***

C sa Prefo w.

E See Pfee for egg, lengtfi of g,e,,,,

a l

~,

y-y m.3 1

M@

' ?!* S.**p$w ggL7.

h-L 76 1 - _t.. a at W (. - w-TM sittases as nam tel 3*.e* se seeeral Plaat aree Ibi 1* *4* to tante speendaag aree 4e8 Watt estu e

&* ensa.3 eseapoenge, i

'~ -

/

e e

- )

e

' 'f _ ',.,

/,

-,3 7.,. ;.-

.,,, y5, a p m,

gy

(

v.

?,

4 w-.,

Attcchment 6.6 QI-008-Rev. 1 Page'1 of I C

/

I i

e4ma t==

g mm sama Taast II' 1b 2

=v 1 Y $.=C N

s, d

X Ac

.y feasse r A

f.

dJ. ~ '

. /tlE

,t/

F

'(

hl

/

(1 w

' DETAll 45 i/

A 5 % ;ttthrJ.n. y sacall.".'.A h g.

e,,,,,,,s.'s <=wr J

nW

= * ***

m m==s DETAll 49

.. ~ ~

,y.yggg,,

.ca..._.

i =_v..

ma==r i

cau.

,s a..== n a 1%,a (NkA

},.

' *M "N"N I

-,,,.t.

s I

\\

/ (a ~.orses g,

y 1

i mas.

t,,,,

.):$adet F

J

.C*

9,.L l l2 pM'.WnY i

uN c w

U 57.n'"J'e,"u. * ""

ptaw a sueesome rm s s y

tea.= *s' d,

,C_raarrues

.k'O D

'4 ate'as ensemat suaw mana T

l I

I ipto as cans.a asenae.*

e

$ECTION 'Cd*

46ses etu asua coisa I rw I*

p

.is E'ZA'.**.'bMd*4'#.R 'er SECT 4N.h,E, es casansas6s>seeinonraa comovercaeansees messaowfA m TaAs

,, e. DETAll 47.ve.

m

.n

-=

gggnp.geng OS Stampee EI 6TSi&MIT.AE86 t=

a.gm**.'5Er",r4""~a OW 5

N w-4

... p.,s.y5."L. ;y

/..

v.

Y r.

t.,

Attcchment 6.7 c.

QI-008 Rev. 1 Page 1 of 1

(*

l

.e

= = -

\\rus, _

c 1

m.,

u-

' un-

      • C.

ea_

% Mi> tin f

==. -c l

w

.)

~~--

..+-

.s.

=

v cae6sve,

w---

x,

,, w.

.v y

6 a'~ ~~ = am ~..

a, r.

Y W. hr#.g?lL.!!J '$'F'L'?. "

DETAIL 57

' mt.

%"*.La"."Mt, g u i.

. 4L"Etr"o"* l

.iH...

... m.

(

1c.=,

p

m,J ljj))]L or

[.,.us e,u w3, i

~.t e,

s<>

t& Cose.Utf y

J (64.6me,se easv) i DETAll GOA DETAIL boc TYPDC AL amrait sca ssPa=&T10h4 T PacAL MTast pot. SEPaaAf. test asettee&asessf5 Os selg er me t 6.9MW 4 uttaseSMfD 08 efhte, Te4Ame6 Seaw SY$rdne

.r t."'J.*"J.4'i!*ta"r at %"gra e e m.co e ica-en.es er a.ca. -

a' e'eseas case? assess 4 esT ngA is C sefae8tsee4 RaftedA M

8 84

34. esc.

8 (est.6w.es.ff46v) eset Camdbu 3e 94 toit EJt80048

34. Sat 4.a,.svMa (ea,6=,sesee')

saaessa cha6s s

cAmot sw. s t 's v e

DETAll 60h DETAIL " ECD a.s o.aaic,a.r.n.a.r'.et.s. rom s.a.J.aa,aAt.te e tv.a t

e

.vv.e.ic4a.a.ra a.a.s.e.e.naa.r.asas.es4.=v c..ra.

t awa ~ -4 maa.6sc

.caram a*+saw s

c

.a

.armarie r..w.r aa.m 6..a eu avn

....w v

= =v I

l CETAll GO i

vv ca u,as.avie estiEassfee. bas m4Af tens aseepeta Ese.7b es sets a

l su.stSea. 8M&taL.& san.D e er posta paAss es wwwemassestappapmThpe N W.

te LAfu T 4 AbfG4 ft s

+.%-

g

' Tav. pd* = we

  • w D

o.

. ra L

  • Qud ;k gy u.

x

.s

,a3 s

t

, - -. ~

L...

Attcchment 6.8 j

QI-008 2

Rev. 1 q

Page 1 of 1 1-C 1

ss v e

..,g.,u,y.

4.gg,,,,,,,

sf EA

    • X wh5**A

[wv.,,"' ]

,,Y, P'*""'*

sj oc a

>c.ia.a,,,=,,

e r

- -.u C"o"n'.EE)a gT#,M,,,,a "

".'"sT. inw I

I's (

u M".bj."I WJ:"'.f.l5t."m*.'

n I

Ly tes),,,

,c i

f,

/

  • t DETAll. swam = W, 53 vv e u.a^".!.#.!.%

I.

QETAIL 52 is 6. cam..t x

i

.g. m. c.

v

. rb.. Jet'.ftiga.*;'em"..Mi'"ig

w...

r.

.v" 7

',)S****w.

ad 4.

4 w...

w as...

.r

. m...,

,...,. -.,....=v._,.,. a v..v..

c r.hi.'"4

.,r

,2,

J

',s,-

9-g.a.

..asi r, a..,.=

.s.r...,...

_s...s.,

a 13.

..... m

,,a 4

-(( 6 3..

o..

1

.. ~

,.u.

<c r...

.e.

a.

~.

4%L. 5. 4.

.).:..

.a... ~a

_D,ETAI ea.

wa e

e3 a.

Sgaf,M'7.'M&'8,"j 2w.,=

h y..~.r g

r.......ay w.m <.

.s. us m

<v i

s

<= = '. * >

l

6. &

t

.w...,

.*..m.s A*M.

O A g

4

".M.a sie.

,. 84 u. s *.

/

DETAIL 55 g.u.

2.[ t.=ou w =.Avien (rit as"

"""'.W.'1 vF,la/M 4}

2

.4 ; ma r-vsT

~

},

' V **sA%

E y t 4-Q%

' "f

,., _ g x ;d y s.m.}-

8.;;

  • ; +y

.+

q--. 9 s

o e

+

Attcchesnt 6.9 e

QI-008 Rev. 1 i

Page 1 of 2 f

COMANCNE PEAR REVIEW TEAM CHECELIST PortuTION DESCRIPTION POP. 140.

DATE Ceeduit FACE 1 0F 2 REIIISPECTION h IRilf O'

D DOCISIENPREVIEWC COPMON AREA C

PACE OP EQUIPMENT IERE/ TAG NO.

EQU1P/5 AMPLE DESCRIPTION VE11PICAT10N PEC. NO.

VERIPICATION EDtARKS ATTRISCTE ACCEPT REJECT DATE (special instr. deviation me. etc.)

1) Sise e

A b

X'/

\\ \\/)

2) Identification a b

\\\\A e

/T

\\ */

t \\TI V

v

3) Origin and Destinatien Ah

(

A) Pittinge a

b A

NW

~

c 5 kN

\\/

d

\\ h\\

1

("Af

5) Espenetoo i %

V Pittings g

I 6>

s..d.

v i

7) Length and Pull Pointe FREPARED BY DATE AP PROVG 81 DATE APPROV G SY DATE DISCIPLINE ENGR.

REINSP. ENCR. SL'PRV.

REVIEW TEAM LEADER PROCE5 SED 31 DATE APPROVG SY DATE j

DISCIPLINE EECR.

LEAD DISCIPLINE EhCR.

INSFEsans af DATE POP. INSPECT. PROC D.

APP 30V G SY DATE i

REV.t DATE t

INSPECTOR

' E^n IN5FECTOR COP-qAI-003.1 6/ss 5037-C(0)o6/26/ss 1

s

.., -/

v up, h.e.

U k

T Vg

f.J*

s Attcetusent 6.9 QI-008

.J f

Rev. I i

Page 2 of 2

?

CONANCNE FEAR REVIEW TEAN CNECKLIST POPUIAT10ll DESCRIPTION POP. 110.

DATE:

Ceedwit PACE 2 0F 2 REIIISPECTION O DIIIT O

DOCIMENT REVIEVO C.oi. TON AREA m

e, 54U1PMENT WAAK/ TAC MO.

EQUIP /SANFLE DESC11PTICII VER1FICAT10N PEG. No.

VERI ricATION REMARKS ATTR19UTE ACCEPT REJECT DATE (special instr. deviation no. etc.)

0) Flesible Conduit a

/%

b A

X"f e

\\\\

v 4

h XX A I. A

\\ V/

q G

V

9) Cable Trey V

Interface e

A

~

b i

X XT ATA\\

V k

10) Clearance a

b A

\\ \\M

((N M

!!) Fire Stops and Seals el O a2 1 ('

31 bi A_

T b2

.11 4 ~1

12) Separation al bl W

c1 c2 j

c3 ce di d2 el et

/

s CQF-QAI-003.la 6/05 5037-C(0)06/26/05

,,'i ;*

.,. 4..I s'/,. [ 's '..$.$Y w I'

+

s

'.1 e

~;_

e p :;q *;., y y e ;-

'^ !

__