Byron: Difference between revisions

From kanterella
Jump to navigation Jump to search
No edit summary
No edit summary
 
(One intermediate revision by the same user not shown)
Line 2: Line 2:
|name=Byron
|name=Byron
|acronym=BYR
|acronym=BYR
|full name=Byron Nuclear Generating Station
|site type=Plant
|site type=Plant
|region=3
|region=3
Line 8: Line 9:
|ISFSI docket=07200068
|ISFSI docket=07200068
|mapping location=42° 4' 36.26" N, 89° 16' 52.14" W
|mapping location=42° 4' 36.26" N, 89° 16' 52.14" W
|company=Exelon
|company=Constellation
|company history={{company history
|transfer from=Exelon
|transfer to=Constellation
|transfer date=February 2, 2022
|transfer record=ML22021B659
}}
|wikipedia=Byron Nuclear Generating Station
|wikipedia=Byron Nuclear Generating Station
|site unit={{Site unit
|site unit={{Site unit
|Unit number=1
|Unit number=1
|Power=3645
|Power=3645 MWt
|Docket=05000454
|Docket=05000454
|is cancelled=No
|is cancelled=No
|License=NPF–37
|Commission date=02/14/1985
|Reactor type=Westinghouse PWR 4-Loop
|Reactor type=Westinghouse PWR 4-Loop
|Containment type=Ambient Pressure
|Containment type=Ambient Pressure
|Ultimate heat sink=Cooling Tower
|url=https://www.nrc.gov/info-finder/reactors/byro1.html
|url=https://www.nrc.gov/info-finder/reactors/byro1.html
}}{{Site unit
}}{{Site unit
|Unit number=2
|Unit number=2
|Power=3645
|Power=3645 MWt
|Docket=05000455
|Docket=05000455
|is cancelled=No
|is cancelled=No
|License=NPF–66
|Commission date=01/30/1987
|Reactor type=Westinghouse PWR 4-Loop
|Reactor type=Westinghouse PWR 4-Loop
|Containment type=Ambient Pressure
|Containment type=Ambient Pressure
|Ultimate heat sink=Cooling Tower
|url=https://www.nrc.gov/info-finder/reactors/byro2.html
|url=https://www.nrc.gov/info-finder/reactors/byro2.html
}}
}}
}}
}}

Latest revision as of 19:06, 22 March 2022

Byron (BYR)
Byron Nuclear Generating Station
Plant
Company ConstellationConstellation icon.png
Where Rock River, Illinois
Regulatory
Region NRC Region 3
ISFSI docket 07200068
Company History
Exelon->Constellation (February 2, 2022)
wikipedia link
Reactor Unit 1
Docket 05000454
License NPF–37
Licensed Power Level (Thermal) 3645 MWt
Unit type Westinghouse PWR 4-Loop
Containment Ambient Pressure
Ultimate Heat Sink Cooling Tower
Status
Commission 02/14/1985
NRC Website
Reactor Unit 2
Docket 05000455
License NPF–66
Licensed Power Level (Thermal) 3645 MWt
Unit type Westinghouse PWR 4-Loop
Containment Ambient Pressure
Ultimate Heat Sink Cooling Tower
Status
Commission 01/30/1987