ML17228B033: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
(3 intermediate revisions by the same user not shown)
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:St.LucieUnit1andUnit2DocketNos.50-335and50-389ProposedLicenseAmendmentsContainmentAirLockAutomaticTesterATTACHMENT3ST~LUCIEUNIT1MARKED-UPTECHNICALSPECIFICATIONPAGESPage3/46-1195030l0194950222PDRADOCK05000335PPDR CONTAINMENTSYSTEMSCONTAINMENTAIRLOCKSSURVEILLANCEREUIREMENTSContinuedl.Forthepersonnelairlock,greaterthanorequaltoPa,39.6psigforatleast15minutes>notesewtteaoscse.2.Fortheemergencyairlock,greaterthanorequaltoforatleast15minutes.b.Byconductingoverallairlockleakagetestsatnotlesspsig,andverifyingtheoverallairlockleakagerateislimit:10.0psigthanPa,39.6withinitsl.Atleastonceper6months,>>and2.PriortoestablishingCONTAINMENTINTEGRITYwhenmaintenancehasbeenperformedontheairlockthatcouldaffecttheairlocksealingcapability.*c.Atleastonceper6monthsbyverifyingthatonlyonedoorineachairlockcanbeopenedatatime.>>TheprovisionsofSpecification4.0.2arenotapplicable.*ThisconstitutesanexemptiontoAppendixJof10CFR50.ST.LUGIE-UNIT13/46-11AmendmentNo.
{{#Wiki_filter:St. Lucie Unit  1 and Unit 2 Docket Nos. 50-335 and 50-389 Proposed License Amendments Containment Air Lock Automatic Tester ATTACHMENT 3 ST ~ LUCIE UNIT 1 MARKED-UP TECHNICAL SPECIFICATION PAGES Page  3/4 6-11 95030l0194 950222 PDR  ADOCK  05000335 P                PDR
Q St.LucieUnit1andUnit2DocketNos.50-335and50-389ProposedLicenseAmendmentsContainmentAirLockAutomaticTesterATTACHMENT4ST~LUCIEUNIT2MARKED-UPTECHNICALSPECIFICATIONPAGESPage3/46-10 CONTAINMENTSYSTEMSSURVEILLANCEREUIREMENTS4.6.1.3EachcontainmentairlockshallbedemonstratedOPERABLE:a0Within72hoursfollowingeachclosing,exceptwhentheairlockisbeingusedformultipleentries,thenatleastonceper72hours,byverifyingthesealleakageis<0.01Lasdeterminedbyprecisionflowmeasurementwhenthevolumebetweenthedoorsealsispres-surizedtogreaterthanorequalto:1.Forthepersonnelairlock,greaterthanoreualtoP,41.8psigforatleast15minutes~eutomb.2.Fortheemergencyairlock,greaterthanorequalto41.8psigforatleast15minutes.ByconductingoverallairlockleakagetestsatnotlessthanP,41.8psig,andverifyingtheoverallairlockleakagerateiswfthinitslimit:l.Atleastonceper6months,andC.2.PriortoestablishingCONTAINMENTINTEGRITYwhenmaintenancehasbeenperformedontheairlockthatcouldaffecttheairlocksealingcapability.*Atleastonceper6monthsbyverifyingthatonlyonedoorineachairlockcanbeopenedatatime.TheprovisionsofSpecification4.0.2arenotapplicable.*ThisconstitutesanexemptiontoAppendixJof10CFR50.ST.LUCIE-UNIT23/46-10Amendmentno./B k,Y>Mt'I~%V%'0P~~...,a/p,~~L,s.~>}}
 
CONTAINMENT SYSTEMS CONTAINMENT  AIR  LOCKS SURVEILLANCE RE UIREMENTS        Continued
: l. For the personnel  air lock, greater than or equal to Pa, 39.6 psig foratleast15minutes        > no tese  wt tea      o    sc    se.
: 2. For the emergency air lock, greater    than or equal to 10.0 psig for at least  15  minutes.
: b. By conducting overall air lock leakage tests at not less than Pa, 39.6 psig,  and verifying the overall air lock leakage rate is within its limit:
: l. At least once per    6 months,>> and
: 2. Prior to establishing    CONTAINMENT INTEGRITY when maintenance  has been performed on    the air lock that could affect the air lock sealing capability.*
: c. At least once per 6 months by verifying that only one door in each air lock can be opened at a time.
>>The provisions of Specification 4.0.2 are not applicable.
*This constitutes an exemption to Appendix J of 10 CFR 50.
ST. LUG IE  - UNIT  1              3/4 6-11          Amendment No.
 
Q St. Lucie Unit  1 and  Unit 2 Docket Nos. 50-335 and 50-389 Proposed License Amendments Containment Air Lock Automatic Tester ATTACHMENT 4 ST ~ LUCIE UNIT 2 MARKED-UP TECHNICAL SPECIFICATION PAGES Page  3/4 6-10
 
CONTAINMENT SYSTEMS SURVEILLANCE RE UIREMENTS 4.6. 1.3  Each containment  air lock shall  be demonstrated  OPERABLE:
a0  Within 72 hours following each closing, except      when  the air lock is being used  for multiple entries,   then at least once per 72 hours, by verifying  the  seal leakage is < 0. 01 L as determined by precision flow measurement when the volume between the door seals is pres-surized to greater than or equal to:
1.
41.8 psig for at least 15 minutes eutom
                                                      ~
For the personnel air lock, greater than or    e  ual to P  ,
: 2. For the emergency  air lock, greater than or equal to 41.8 psig for at least  15 minutes.
: b. By conducting overall air lock leakage tests at not less than P ,
41.8 psig, and verifying the overall air lock leakage rate is wfthin its limit:
: l. At least    once per 6 months,   and
: 2. Prior to establishing  CONTAINMENT INTEGRITY when    maintenance has been performed on  the air lock that  could affect the  air lock sealing capability.*
C. At least once per 6 months by verifying that only one door in each air lock can be opened at a time.
The  provisions of Specification 4.0.2 are not applicable.
This constitutes an exemption to Appendix J of 10 CFR 50.
ST. LUCIE - UNIT 2                    3/4 6-10                Amendment  no./B
 
k, P ~  ~
            ~
Y >Mt 'I ...,a %
                /
V % '0 p, ~ ~ L,s. ~ >}}

Latest revision as of 12:32, 4 February 2020

Proposed TS 4.6.1.3,reflecting Deletion of Refs to Automatic Tester for Containment Personnel Air Lock
ML17228B033
Person / Time
Site: Saint Lucie  NextEra Energy icon.png
Issue date: 02/22/1995
From:
FLORIDA POWER & LIGHT CO.
To:
Shared Package
ML17228B032 List:
References
NUDOCS 9503010194
Download: ML17228B033 (6)


Text

St. Lucie Unit 1 and Unit 2 Docket Nos. 50-335 and 50-389 Proposed License Amendments Containment Air Lock Automatic Tester ATTACHMENT 3 ST ~ LUCIE UNIT 1 MARKED-UP TECHNICAL SPECIFICATION PAGES Page 3/4 6-11 95030l0194 950222 PDR ADOCK 05000335 P PDR

CONTAINMENT SYSTEMS CONTAINMENT AIR LOCKS SURVEILLANCE RE UIREMENTS Continued

l. For the personnel air lock, greater than or equal to Pa, 39.6 psig foratleast15minutes > no tese wt tea o sc se.
2. For the emergency air lock, greater than or equal to 10.0 psig for at least 15 minutes.
b. By conducting overall air lock leakage tests at not less than Pa, 39.6 psig, and verifying the overall air lock leakage rate is within its limit:
l. At least once per 6 months,>> and
2. Prior to establishing CONTAINMENT INTEGRITY when maintenance has been performed on the air lock that could affect the air lock sealing capability.*
c. At least once per 6 months by verifying that only one door in each air lock can be opened at a time.

>>The provisions of Specification 4.0.2 are not applicable.

  • This constitutes an exemption to Appendix J of 10 CFR 50.

ST. LUG IE - UNIT 1 3/4 6-11 Amendment No.

Q St. Lucie Unit 1 and Unit 2 Docket Nos. 50-335 and 50-389 Proposed License Amendments Containment Air Lock Automatic Tester ATTACHMENT 4 ST ~ LUCIE UNIT 2 MARKED-UP TECHNICAL SPECIFICATION PAGES Page 3/4 6-10

CONTAINMENT SYSTEMS SURVEILLANCE RE UIREMENTS 4.6. 1.3 Each containment air lock shall be demonstrated OPERABLE:

a0 Within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> following each closing, except when the air lock is being used for multiple entries, then at least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, by verifying the seal leakage is < 0. 01 L as determined by precision flow measurement when the volume between the door seals is pres-surized to greater than or equal to:

1.

41.8 psig for at least 15 minutes eutom

~

For the personnel air lock, greater than or e ual to P ,

2. For the emergency air lock, greater than or equal to 41.8 psig for at least 15 minutes.
b. By conducting overall air lock leakage tests at not less than P ,

41.8 psig, and verifying the overall air lock leakage rate is wfthin its limit:

l. At least once per 6 months, and
2. Prior to establishing CONTAINMENT INTEGRITY when maintenance has been performed on the air lock that could affect the air lock sealing capability.*

C. At least once per 6 months by verifying that only one door in each air lock can be opened at a time.

The provisions of Specification 4.0.2 are not applicable.

This constitutes an exemption to Appendix J of 10 CFR 50.

ST. LUCIE - UNIT 2 3/4 6-10 Amendment no./B

k, P ~ ~

~

Y >Mt 'I ...,a %

/

V % '0 p, ~ ~ L,s. ~ >