WBL-20-022, Unit 1 Revision 0 of the Cycle 17 Core Operating Limits Report (COLR)

From kanterella
Jump to navigation Jump to search
Unit 1 Revision 0 of the Cycle 17 Core Operating Limits Report (COLR)
ML20141L521
Person / Time
Site: Watts Bar Tennessee Valley Authority icon.png
Issue date: 05/20/2020
From: Anthony Williams
Tennessee Valley Authority
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
WBL-20-022
Download: ML20141L521 (13)


Text

[iID Tennessee Valley Authority, Post Office Box 2000, Spring City, Tennessee 37381-2000 WBL-20-022 May 20, 2020 10 CFR 50.4 ATTN : Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Watts Bar Nuclear Plant, Unit 1 Facility Operating License No. NPF-90 NRC Docket No. 50-390

Subject:

UNIT 1 REVISION O OF THE CYCLE 17 CORE OPERATING LIMITS REPORT (COLR)

Pursuant to Watts Bar Nuclear Plant Technical Specifications (Tech Spec) Section 5.9.5.d, Tennessee Valley Authority (TVA) has enclosed Revision O of the Unit 1 Cycle 17 CORE OPERATING LIMITS REPORT (COLR). The analytical methods used to determine the core operating limits were previously reviewed and approved by the NRC .

There are no regulatory commitments contained in this letter or the enclosure. Should you have questions regarding this submittal, please contact Tony Brown , Site Licensing Manager at (423) 365-7720.

ny L. illiams, IV Site Vice President Watts Bar Nuclear Plant

U.S. Regulatory Commission Page 2 WBL-20-022 May 20, 2020

Enclosures:

Watts Bar Nuclear Plant, Unit 1, Cycle 17 Core Operating Limits Report, Revision 0, March 2020 cc (Enclosure):

NRC Regional Administrator - Region II NRR Project Manager NRC Senior Resident Inspector

ENCLOSURE 1 Watts Bar Nuclear Plant, Unit 1, Cycle 17 Core Operating Limits Report Revision 0 March 2020

QA Record L36 200324 801 WATTS BAR NUCLEAR PLANT, UNIT 1, CYCLE 17 CORE OPERATING LIMITS REPORT Revision 0 March 2020 Prepared by:

°"Jhlly sigMd by a.II. unwl C Be 11, Jam eI C ON:dcagov.dcwtv._dc-.min.o""~in.ou=Corponl*.D<PUstn.cn=Bell unwl c. *<Nilzj(bo-lllOtva.gov llffson: I am 1M i!Jlhor of !his doc-I

_ _ _ _ _ _ _ _ _ _ _o._,,_,202_0D_12s_oa:Ja_:29_-04_w_ _ _ _ _ _ _ / _ _ _ _ _ __

J.C. Bell, PWR Fuel Engineering Date Verified by:

---!-.~P---OJAV-etz__,*e_r.....,,,~,,,._W_~,....._ue_l....,..,...g-i-ne-e-ri-ng_ _ _ _ _ _ _ _ _ _ /

63 /~~l!oza Reviewed by:

Digitally signed by Ritchi*, John A Ritchie, John A ON: dcagov, dcatva, dc~main, ouaMain, ousCorporat,. oo~Uic11, cnaRitchi*. John A, rmaila)aritchi,Oetva.gov Reason: I have ll!Yirwed this documrnt

- - - - - - - - - - - - - - - - - - - - - I - - - Date Oare: 2020Dl.25 09-.32:lO -04'00'

-J.A. Ritchie, PWR Fuel Engineering Manager Ma Ck, Bryan Th Om aS Digitally signed by Mack, Bryan Thomas Date: 2020.03.31 16:0p:44 -04'00' B.T. Mack, Reactor Engineering Manager Date

~roved,~

-C-.L-.§_R .....

ic'+'--,P_O_R_C_C_h_a*-irm_a_n_ _ _ _ _ _ _ _ _ _ _ _ _ _ /

- - - - - - - - - - - - - - - - - - - - - - ' - - - Date T.B. Marshall, Plant Manager Date of PORC Affected Revision Aooroval Pages Reason for Revision 0 See Above All Initial Issue Unit 1 Cycle 17 WATTS BAR Page 1 of 10 Revision 0

1.0 CORE OPERATING LIMITS REPORT This Core Operating Limits Report (COLR) for Watts Bar Unit 1 Cycle 17 has been prepared in accordance with the requirements of the Technical Specifications 5.9.5.

The Technical Specifications affected by this report are listed below:

3.1.4 Moderator Temperature Coefficient (MTC) 3.1.5 Rod Group Alignment Limits 3.1.6 Shutdown Bank Insertion Limits 3.1.7 Control Bank Insertion Limits 3.2.1 Heat Flux Hot Channel Factor (FQ(Z))

3.2.2 Nuclear Enthalpy Rise Hot Channel Factor (F'HN) 3.2.3 Axial Flux Difference (AFD) 3.9.1 Boron Concentration 2.0 OPERATING LIMITS The cycle-specific parameter limits for the specifications listed in section 1.0 are presented in the following subsections. These limits have been developed using the NRC approved methodologies specified in the Technical Specifications Section 5.9.5.

The following abbreviations are used in this section:

BOL -- Beginning of Cycle Life ARO -- All Rods Out HZP -- Hot Zero Thermal Power EOL -- End of Cycle Life RTP -- Rated Thermal Power 2.1 MODERATOR TEMPERATURE COEFFICIENT - MTC (LCO 3.1.4) 2.1.1 The MTC limits are:

The ARO/HZP - MTC shall be less positive than or equal to 0 'k/k/qF (upper limit).

With the measured BOL/ARO/HZP - MTC more positive than -3.553 x 10-5 k/k/°F (as-measured MTC limit), establish control rod withdrawal limits to ensure the MTC remains less positive than or equal to 0 'k/k/qF (upper limit) for all times in core life.

The EOL/ARO/RTP - MTC shall be less negative than or equal to

-4.5 x 10-4 k/k/°F (lower limit).

2.1.2 The 300 ppm surveillance limit is:

The measured 300 ppm /ARO/RTP-MTC should be less negative than or equal to

-3.75 x 10-4 k/k/°F.

2.1.3 The 60 ppm surveillance limit is:

The measured 60 ppm /ARO/RTP-MTC should be less negative than or equal to

-4.28 x 10-4 k/k/°F.

Unit 1 Cycle 17 WATTS BAR Page 2 of 10 Revision 0

2.2 SHUTDOWN MARGIN - SDM (LCO 3.1.5, 3.1.6, 3.1.7) 2.2.1 )RU766'0VKDOOEHk/k in MODE 1 and MODE 2.

2.2.2 )RU766'0VKDOOEHk/k in MODE 1 and MODE 2.

2.2.3 )RU766'0VKDOOEHk/k LQ02'(DQG02'(ZLWKNHII

2.3 SHUTDOWN BANK INSERTION LIMITS (LCO 3.1.6) 2.3.1 The shutdown banks shall be withdrawn to a position greater than or equal to 225 steps withdrawn.

2.4 CONTROL BANK INSERTION LIMITS (LCO 3.1.7) 2.4.1 The control banks are fully withdrawn or shall be limited in physical insertion as shown in Figure 1.

2.4.2 Each control bank shall be considered fully withdrawn from the core at greater than or equal to 225 steps.

2.4.3 The control banks shall be operated in sequence by withdrawal of Bank A, Bank B, Bank C, and Bank D. The control banks shall be sequenced in reverse order upon insertion.

2.4.4 Each control bank not fully withdrawn from the core shall be operated with the following overlap as a function of park position.

Park Position (steps) Bank Overlap (steps) Bank Difference (steps) 225 109 116 226 110 116 227 111 116 228 112 116 229 113 116 230 114 116 231 115 116 2.5 HEAT FLUX HOT CHANNEL FACTOR - FQ(Z) (LCO 3.2.1)

FQ(Z) d [CFQ / P]

  • K(Z) for P > 0.5 FQ(Z) d [CFQ / 0.5]
  • K(Z) for P d 0.5 Where P = Thermal Power / Rated Thermal Power 2.5.1 CFQ = 2.50 Unit 1 Cycle 17 WATTS BAR Page 3 of 10 Revision 0

2.5.2 K(Z) is provided in Figure 2.

2.5.3 FQW(Z) = FQc(Z)

  • W(Z)/P for P > 0.5 FQW(Z) = FQc =  : = IRU3

where: W(Z) values are provided in Tables A.1 and A.3. Table A.1 contains normal W(Z) factors based on the non-perturbed model. Table A.3 contains W(Z) factors based on the perturbed model.

The data in Tables A.1 and A.3 should be used independently; cross interpolation or extrapolation between W(Z) sets is prohibited.

Table A.1 values should be used when D-AO is in the range of -3% DQG +3%.

Table A.3 values should be used when D-AO is in the range of 0% DQG +6%.

These tables provide sufficient information to determine W(Z) versus core height for all cycle burnups.

2.5.4 Part power W(Z) values are only required to be used when the part power surveillance is performed using the moveable incore detector system.

2.5.5 FQW(Z) Penalty Factor The FQW(Z) penalty factor is provided in Table A.2.

2.6 NUCLEAR ENTHALPY RISE HOT CHANNEL FACTOR - F'HN (LCO 3.2.2)

F'HN d F'HRTP * ( 1 + PF * ( 1-P))

where P = Thermal Power / Rated Thermal Power F'HRTP = 1.65 for RFA-2 fuel, and PF = 0.3 2.7 AXIAL FLUX DIFFERENCE - AFD (LCO 3.2.3) 2.7.1 The AFD limits for Cycle 17 are provided in Figure 3.

2.8 REFUELING BORON CONCENTRATION (LCO 3.9.1) 2.8.1 The refueling boron concentration shall be t 2000 ppm.

3.0 NUMBER OF TPBARS IN REACTOR CORE (TS 4.2.1) 3.0.1 There are 1792 tritium producing burnable absorber rods (TPBARs) in the reactor core for Cycle 17.

Unit 1 Cycle 17 WATTS BAR Page 4 of 10 Revision 0

250

~ BANK A H (ALL POWERS, 225) 225 , ~

I/ (0.197, 225) / I (0.703, 225) I

, ~

,, ;jr' 200

j BANK B I I

, ~

I (1.0, 177) r ROD BANK STEP POSITION (STEPS WITHDRAWN)

,J 175 I l (0.0, 180) I ,,

, , r' 150

, , ,J I/

I/

L BANK C I

,, ;jr' 125 ,

, "r'

,, I/

~

100

, ~

I BANK D I 75

, ~

, ~

(0.0, 64) I I

, ;j r' 50

, ,J 25

- - 4 (0.227, 0)

I I ,,,

I I I 0 -

0.0 0.2 0.4 0.6 0.8 1.0 FRACTION OF RATED THERMAL POWER Figure 1 Control Bank Insertion Limits Versus Thermal Power Four Loop Operation Note: Fully withdrawn region shall be the condition where shutdown and control banks are at a position within the interval of t 225 and d 231 steps withdrawn.

Unit 1 Cycle 17 WATTS BAR Page 5 of 10 Revision 0

1.2 1.1 1.0 0.9 0.8 Normalized FQ

  • Power 0.7 0.6 Core Height K(Z) -

0.000 1.000 6.000 1.000 12.000 0.9256 0.5 0.4 0.3 0.2 0.1 0

0 2 4 6 8 10 12 Core Height (feet)

Figure 2 K(Z) - Normalized FQ(Z) as a Function of Core Height Unit 1 Cycle 17 WATTS BAR Page 6 of 10 Revision 0

120 110 I (-12, 100) 1 1 (7, 100) I 100 I \

I 90 I

Acceptable Operation

'\

80 -

Unacceptable I \ Unacceptable -

Operation I \ Operation

% of Rated Thermal Power 70 J \

I \

60 I \

I 50 I

I

(-28, 50) I I

' \

(21, 50) I 40 30 20 10 Figure 3 Axial Flux Difference Acceptable Operation Limits as a Function of Rated Thermal Power (RAOC) 0

-50 -40 -30 -20 -10 0 10 20 30 40 50 Flux Difference ('I) %

Figure 3 Axial Flux Difference Acceptable Operation Limits as a function of Rated Thermal Power (RAOC)

Unit 1 Cycle 17 WATTS BAR Page 7 of 10 Revision 0

Table A.1 RAOC W(Z) Surveillance Factors (Normal Model) for D-AO of -DQG

Max W(z) Max W(z) Max W(z) Max W(z) Max W(z) Max W(z) Max W(z) Max W(z) Max W(z) at 150 at 150 at 150 at 4000 at 6000 at 8000 at 12000 at 16000 at 18000 Height MWD/MTU MWD/MTU MWD/MTU MWD/MTU MWD/MTU MWD/MTU MWD/MTU MWD/MTU MWD/MTU (ft)

(30% (75% (100% (100% (100% (100% (100% (100% (100%

Power) Power) Power) Power) Power) Power) Power) Power) Power) 12.0740 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 11.8728 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 11.6715 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 11.4703 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 11.2691 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 11.0678 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 10.8666 1.4763 1.4704 1.2823 1.3044 1.2570 1.1906 1.1504 1.1418 1.1588 10.6654 1.4314 1.4256 1.2785 1.2982 1.2522 1.1884 1.1484 1.1400 1.1573 10.4641 1.3870 1.3792 1.2719 1.2891 1.2447 1.1859 1.1440 1.1356 1.1532 10.2629 1.3406 1.3293 1.2631 1.2781 1.2386 1.1825 1.1380 1.1300 1.1474 10.0617 1.3038 1.2890 1.2531 1.2657 1.2315 1.1780 1.1308 1.1217 1.1407 9.8604 1.2698 1.2510 1.2418 1.2615 1.2220 1.1748 1.1235 1.1183 1.1330 9.6592 1.2363 1.2165 1.2307 1.2630 1.2115 1.1740 1.1201 1.1222 1.1274 9.4580 1.2079 1.1898 1.2245 1.2598 1.2064 1.1743 1.1225 1.1243 1.1273 9.2567 1.1925 1.1782 1.2307 1.2557 1.2043 1.1702 1.1238 1.1294 1.1335 9.0555 1.1804 1.1739 1.2384 1.2499 1.2020 1.1662 1.1243 1.1336 1.1421 8.8543 1.1650 1.1692 1.2415 1.2409 1.1973 1.1637 1.1277 1.1357 1.1492 8.6530 1.1491 1.1639 1.2427 1.2314 1.1938 1.1637 1.1370 1.1400 1.1555 8.4518 1.1313 1.1572 1.2415 1.2253 1.1955 1.1689 1.1514 1.1499 1.1659 8.2506 1.1121 1.1502 1.2385 1.2182 1.1954 1.1723 1.1637 1.1605 1.1771 8.0493 1.0932 1.1427 1.2336 1.2107 1.1931 1.1734 1.1737 1.1721 1.1893 7.8481 1.0743 1.1351 1.2274 1.2040 1.1894 1.1734 1.1820 1.1834 1.2009 7.6469 1.0572 1.1281 1.2206 1.1973 1.1842 1.1715 1.1881 1.1922 1.2099 7.4456 1.0422 1.1218 1.2137 1.1893 1.1775 1.1680 1.1923 1.1990 1.2166 7.2444 1.0277 1.1148 1.2052 1.1801 1.1694 1.1684 1.1945 1.2037 1.2212 7.0432 1.0160 1.1086 1.1970 1.1719 1.1604 1.1689 1.1948 1.2064 1.2236 6.8419 1.0074 1.1043 1.1902 1.1666 1.1551 1.1673 1.1933 1.2070 1.2237 6.6407 1.0034 1.1024 1.1855 1.1631 1.1543 1.1647 1.1903 1.2058 1.2219 6.4395 1.0023 1.1022 1.1821 1.1581 1.1516 1.1609 1.1859 1.2033 1.2186 6.2382 1.0013 1.1007 1.1769 1.1531 1.1477 1.1552 1.1797 1.1990 1.2134 6.0370 1.0031 1.1011 1.1734 1.1490 1.1453 1.1502 1.1718 1.1928 1.2062 5.8358 1.0073 1.1026 1.1708 1.1445 1.1433 1.1491 1.1629 1.1849 1.1972 5.6345 1.0105 1.1027 1.1662 1.1390 1.1397 1.1514 1.1564 1.1754 1.1865 5.4333 1.0136 1.1020 1.1605 1.1341 1.1363 1.1518 1.1551 1.1665 1.1756 5.2321 1.0190 1.1031 1.1565 1.1304 1.1366 1.1511 1.1558 1.1652 1.1701 5.0308 1.0255 1.1045 1.1528 1.1264 1.1370 1.1497 1.1583 1.1648 1.1704 4.8296 1.0322 1.1060 1.1483 1.1215 1.1362 1.1470 1.1610 1.1648 1.1721 4.6284 1.0389 1.1066 1.1431 1.1162 1.1349 1.1449 1.1628 1.1658 1.1723 4.4271 1.0455 1.1063 1.1372 1.1104 1.1331 1.1459 1.1650 1.1669 1.1718 4.2259 1.0524 1.1055 1.1308 1.1043 1.1308 1.1467 1.1680 1.1674 1.1705 4.0247 1.0593 1.1041 1.1238 1.0977 1.1281 1.1470 1.1710 1.1675 1.1689 3.8234 1.0667 1.1026 1.1166 1.0922 1.1251 1.1470 1.1735 1.1679 1.1662 3.6222 1.0734 1.1007 1.1090 1.0885 1.1222 1.1468 1.1760 1.1699 1.1653 3.4210 1.0814 1.1004 1.1029 1.0852 1.1209 1.1467 1.1798 1.1780 1.1713 3.2197 1.0978 1.1085 1.1050 1.0854 1.1226 1.1467 1.1874 1.1854 1.1774 3.0185 1.1157 1.1173 1.1074 1.0903 1.1331 1.1528 1.1979 1.1938 1.1839 2.8173 1.1382 1.1298 1.1132 1.1032 1.1508 1.1694 1.2144 1.2085 1.1947 2.6160 1.1685 1.1494 1.1264 1.1198 1.1699 1.1892 1.2369 1.2293 1.2090 2.4148 1.1996 1.1688 1.1397 1.1364 1.1890 1.2088 1.2582 1.2488 1.2223 2.2136 1.2314 1.1878 1.1528 1.1531 1.2077 1.2282 1.2789 1.2676 1.2387 2.0123 1.2634 1.2070 1.1653 1.1694 1.2257 1.2470 1.2988 1.2856 1.2556 1.8111 1.2958 1.2261 1.1771 1.1851 1.2427 1.2647 1.3173 1.3023 1.2713 1.6099 1.3278 1.2440 1.1879 1.1997 1.2583 1.2811 1.3342 1.3176 1.2858 1.4086 1.3592 1.2597 1.1965 1.2122 1.2714 1.2949 1.3483 1.3302 1.2978 1.2074 1.3891 1.2718 1.2013 1.2210 1.2806 1.3048 1.3580 1.3384 1.3057 1.0062 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 0.8049 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 0.6037 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 0.4025 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 0.2012 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 0.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 Unit 1 Cycle 17 WATTS BAR Page 8 of 10 Revision 0

Table A.2 FQW(Z) Penalty Factor Cycle Burnup

() Penalty Factor (MWD/MTU) 909 1.0200 1099 1.0204 1289 1.0200 1479 1.0200 1668 1.0212 1858 1.0223 2048 1.0230 2238 1.0232 2428 1.0228 2618 1.0218 2807 1.0203 2997 1.0200 8502 1.0200 8691 1.0202 8881 1.0210 9071 1.0216 9261 1.0222 9451 1.0227 9641 1.0231 9830 1.0233 10020 1.0200 Note:

1. The Penalty Factor, which is applied to FQW(Z) for compliance with Surveillance Requirement 3.2.1.2, is the maximum factor by which FQW(Z) is expected to increase per 31 Effective Full Power Days (EFPD) starting from the burnup at which the FQW(Z) was determined. This Penalty Factor is applicable for both sets of W(Z) Surveillance Factors provided in Tables A.1 and A.3.

Unit 1 Cycle 17 WATTS BAR Page 9 of 10 Revision 0

Table A.3 RAOC W(Z) Surveillance Factors (Perturbed Model) for D-AO of 0DQG

Max W(z) at Max W(z) at Max W(z) at Max W(z) at Max W(z) at Max W(z) at Max W(z) at 150 4000 6000 8000 12000 16000 18000 MWD/MTU MWD/MTU MWD/MTU MWD/MTU MWD/MTU MWD/MTU MWD/MTU Height (ft) (100% Power) (100% Power) (100% Power) (100% Power) (100% Power) (100% Power) (100% Power) 12.0740 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 11.8728 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 11.6715 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 11.4703 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 11.2691 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 11.0678 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 10.8666 1.1965 1.2605 1.2049 1.1293 1.0978 1.1049 1.1425 10.6654 1.2017 1.2558 1.2019 1.1274 1.0973 1.1032 1.1337 10.4641 1.2032 1.2484 1.1963 1.1231 1.0946 1.0990 1.1248 10.2629 1.2025 1.2393 1.1889 1.1201 1.0905 1.0928 1.1088 10.0617 1.1990 1.2311 1.1807 1.1185 1.0854 1.0890 1.0929 9.8604 1.1956 1.2230 1.1707 1.1181 1.0810 1.0885 1.0845 9.6592 1.1937 1.2123 1.1622 1.1217 1.0793 1.0881 1.0849 9.4580 1.1905 1.2007 1.1600 1.1293 1.0796 1.0860 1.0912 9.2567 1.1869 1.2002 1.1607 1.1295 1.0828 1.0881 1.0989 9.0555 1.1880 1.2017 1.1606 1.1291 1.0887 1.0939 1.1074 8.8543 1.1939 1.1981 1.1573 1.1300 1.0963 1.0999 1.1146 8.6530 1.2009 1.1945 1.1545 1.1312 1.1070 1.1060 1.1240 8.4518 1.2067 1.1963 1.1588 1.1385 1.1223 1.1163 1.1423 8.2506 1.2100 1.1963 1.1627 1.1440 1.1358 1.1287 1.1587 8.0493 1.2108 1.1938 1.1649 1.1473 1.1471 1.1421 1.1725 7.8481 1.2096 1.1899 1.1661 1.1495 1.1569 1.1549 1.1848 7.6469 1.2064 1.1844 1.1659 1.1513 1.1649 1.1656 1.1949 7.4456 1.2013 1.1773 1.1644 1.1545 1.1710 1.1745 1.2029 7.2444 1.1941 1.1682 1.1617 1.1580 1.1754 1.1814 1.2088 7.0432 1.1879 1.1613 1.1577 1.1601 1.1779 1.1866 1.2126 6.8419 1.1841 1.1584 1.1552 1.1607 1.1788 1.1898 1.2142 6.6407 1.1820 1.1570 1.1546 1.1603 1.1784 1.1914 1.2140 6.4395 1.1808 1.1540 1.1522 1.1585 1.1766 1.1918 1.2125 6.2382 1.1783 1.1499 1.1493 1.1549 1.1732 1.1905 1.2090 6.0370 1.1736 1.1473 1.1477 1.1519 1.1678 1.1874 1.2036 5.8358 1.1697 1.1447 1.1455 1.1518 1.1624 1.1828 1.1963 5.6345 1.1674 1.1410 1.1432 1.1538 1.1597 1.1762 1.1874 5.4333 1.1641 1.1390 1.1440 1.1553 1.1594 1.1691 1.1788 5.2321 1.1634 1.1391 1.1448 1.1566 1.1586 1.1697 1.1748 5.0308 1.1627 1.1389 1.1464 1.1574 1.1619 1.1708 1.1746 4.8296 1.1607 1.1377 1.1482 1.1565 1.1705 1.1712 1.1768 4.6284 1.1581 1.1360 1.1491 1.1560 1.1786 1.1742 1.1806 4.4271 1.1548 1.1338 1.1494 1.1598 1.1864 1.1795 1.1849 4.2259 1.1508 1.1311 1.1492 1.1637 1.1937 1.1846 1.1887 4.0247 1.1464 1.1284 1.1486 1.1679 1.2007 1.1883 1.1915 3.8234 1.1412 1.1247 1.1480 1.1730 1.2075 1.1956 1.1953 3.6222 1.1363 1.1224 1.1483 1.1793 1.2141 1.2086 1.2016 3.4210 1.1336 1.1257 1.1534 1.1867 1.2206 1.2213 1.2096 3.2197 1.1347 1.1292 1.1589 1.1933 1.2262 1.2336 1.2172 3.0185 1.1438 1.1341 1.1695 1.2036 1.2367 1.2448 1.2243 2.8173 1.1606 1.1458 1.1865 1.2190 1.2560 1.2625 1.2313 2.6160 1.1764 1.1645 1.2065 1.2383 1.2810 1.2885 1.2432 2.4148 1.1953 1.1836 1.2261 1.2607 1.3047 1.3126 1.2651 2.2136 1.2138 1.2023 1.2455 1.2824 1.3277 1.3358 1.2863 2.0123 1.2313 1.2204 1.2641 1.3030 1.3495 1.3577 1.3058 1.8111 1.2480 1.2375 1.2818 1.3225 1.3699 1.3781 1.3243 1.6099 1.2632 1.2531 1.2979 1.3401 1.3884 1.3966 1.3412 1.4086 1.2760 1.2663 1.3115 1.3550 1.4040 1.4121 1.3552 1.2074 1.2846 1.2757 1.3212 1.3657 1.4149 1.4228 1.3648 1.0062 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 0.8049 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 0.6037 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 0.4025 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 0.2012 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 0.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 Unit 1 Cycle 17 WATTS BAR Page 10 of 10 Revision 0