ML051030173

From kanterella
Jump to navigation Jump to search
Core Operating Limits Report for Cycle 7, Revisions 0 and 1
ML051030173
Person / Time
Site: Watts Bar Tennessee Valley Authority icon.png
Issue date: 04/01/2005
From: Pace P
Tennessee Valley Authority
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML051030173 (23)


Text

Tennessee Valley Authority, Post Office Box 2000, Spring City, Tennessee 37381-2000 APR O 12005 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Gentlemen:

In the Matter of the ) Docket No. 50-390 Tennessee Valley Authority WATTS BAR NUCLEAR PLANT (WBN) UNIT 1 - UNIT 1 CORE OPERATING LIMITS REPORT FOR CYCLE 7, REVISIONS 0 AND 1 The purpose of this letter is to provide the Cycle 7 Core Operating Limits Report (COLR) in accordance with WBN Technical Specification 5.9.5.d. Enclosed are Revisions 0 and 1 of the COLR. Revision 0, which was effective on March 11, 2005, was limited to Mode 6 of the Cycle 6 Refueling Outage in order to permit core load. Revision 1 of this report, effective March 18, 2005, is applicable for Cycle 7 operation."

There are no regulatory commitments associated with this submittal. If you have any questions about this letter, please contact me at (423) 365-1824.

ely, Pf.Pace Manager, Site Licensing and Industry Affairs Enclosure Cc: See Page 2 Ado\

U.S. Nuclear Regulatory Commission Page 2 APR 01 2005 Enclosure cc (Enclosures):

NRC Resident Inspector Watts Bar Nuclear Plant 1260 Nuclear Plant Road Spring City, Tennessee 37381 Mr. D. V. Pickett, Project Manager U.S. Nuclear Regulatory Commission MS 08G9 One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2738 U.S. Nuclear Regulatory Commission Region II Sam Nunn Atlanta Federal Center 61 Forsyth St., SW, Suite 23T85 Atlanta, Georgia 30303

U.S. Nuclear Regulatory Commission Page 3 APR 0 i 2005 PLP:RAS cc (Enclosures):

A. S. Bhatnagar, LP 6A-C M. F. DeRoche, ADM 1Q-WBN J. C. Fornicola, LP 6A-C J. E. Hinman, ADM 1B-WBN W. M. Justice, EQB 2A-WBN G. J. Laughlin, MOB 2R-WBN F. C. Mashburn, BR 4X-C NSRB Support, LP 5M-C K. W. Singer, LP 6A-C J. E. Semelsberger, EQB 2W-WBN E. J. Vigluicci, ET 10A-K K. W. Whittenburg, SP2B-C Sequoyah Licensing Files, OPS 4C-SQN EDMS, WT 3B-K M:\SUBMIT\COLR SUBMITTAL FOR CYCLE 7

I .

QA Record L36 050310 802 WATTS BAR NUCLEAR PLANT, UNIT 1, CYCLE 7 MODE 6 CORE OPERATING LIMITS REPORT Revision 0 March 2005 Prepared by: I / C/ '--7 /) Vt .1..I.-i Nuclear Fuel . f Date Verified by:

Nuclear Fuel Date Revie~red by:I/

ManUe, Core Design, Nuclear Fuel Date 1 Ib- Os Reactor Engineering Supervisor Date M by:

Approved g D PORC Chairman Date Plant Managed~' Date Date of PORC PORC Meeting Affected Revision Approval Number Pages Reason for Revision 0 5 / wro 46 3 All Initial issue Unit I Cycle 7 NVAIV1S BAR Page 1 of 2 Revision 0

Mode 6 COLR for Watts Bar Unit 1, Cycle 7 1.0 CORE OPERATING LIMITS REPORT This Core Operating Limits Report (COLR) for Watts Bar Unit 1 Cycle 7 has been prepared in accordance with the requirements of the Technical Specifications 5.9.5.

The Technical Specifications affected by this report are listed below:

3.1.4 Moderator Temperature Coefficient (MTC) 3.1.6 Shutdown Bank Insertion 3.1.7 Control Bank Insertion Limits 3.2.1 Heat Flux Hot Channel Factor (F,(Z))

3.2.2 Nuclear Enthalpy Rise Hot Channel Factor (F,,N) 3.2.3 Axial Flux Difference (AFD) 3.5.1 Accumulators 3.5.4 Refueling Water Storage Tank (RWST) 3.9.1 Boron Concentration 2.0 OPERATING LIMITS This COLR is only valid for mode 6 activities. The COLR must be revised before entering mode 5. The cycle-specific parameter limits for specifications 3.1.4, 3.1.6, 3.1.7, 3.2.1, 3.2.2, and 3.2.3 are not applicable in mode 6 and are not provided. The parameter limits for the specifications 3.5.1, 3.5.4, and 3.9.1 are provided in the following subsections. These limits have been developed using the NRC approved methodologies specified in the Technical Specifications Section 5.9.5.

2.1 REFUELING BORON CONCENTRATION (LCO 3.9.1) 2.7.1 The refueling boron concentration shall be Z 2000 ppm.

2.2 ACCUMULATORS (LCO 3.5.1) 2.8.1 There are 240 tritium producing burnable absorber rods (TPBARs) in the reactor core for Cycle 7.

2.3 REFUELING WATER STORAGE TANK - RWST (LCO 3.5.4) 2.9.1 There are 240 tritium producing burnable absorber rods (TPBARs) in the reactor core for Cycle 7.

Unit 1 Cycle 7 WATTS BAR Page 2 of 2 Revision 0

COLR for Watts Bar Unit 1, Cycle 7 QA Record L36 050318 800 WATTS BAR NUCLEAR PLANT, UNIT 1, CYCLE 7 CORE OPERATING LIMITS REPORT Revision 1 March 2005 Prepared by:

dl5. 1' a

) Date

, /7/5 Nuclear Fuel Verified by:

Nuclear Fuel Date Re iewedby . /

fJl~ Manager, Core Design, Nuclear Fuel Date Y. a? J A X / 6'aa05 Reactor Engineering Supervisor Date Approved by: A PORC Chairman //Date Plant Manager /Date Date of PORC PORC Meeting Affected Revision Approval Number Pages Reason for Revision 0 3/11/05 4073 All Initial issue 1 XlZ1DS W6 All Revised to remove cycle 7 L _ restriction to mode 6 Unit 1 Cycle 7 WATTS BAR Page 1 of 18 Revision 1

COLR for Watts Bar Unit 1, Cycle 7 1.0 CORE OPERATING LIMITS REPORT This Core Operating Limits Report (COLR) for Watts Bar Unit 1 Cycle 7 has been prepared in accordance with the requirements of the Technical Specifications 5.9.5.

The Technical Specifications affected by this report are listed below:

3.1.4 Moderator Temperature Coefficient (MTC) 3.1.6 Shutdown Bank Insertion Limits 3.1.7 Control Bank Insertion Limits 3.2.1 Heat Flux Hot Channel Factor (FQ(Z))

3.2.2 Nuclear Enthalpy Rise Hot Channel Factor (FIIN) 3.2.3 Axial Flux Difference (AFD) 3.5.1 Accumulators 3.5.4 Refueling Water Storage Tank (RWST) 3.9.1 Boron Concentration 2.0 OPERATING LIMITS The cycle-specific parameter limits for the specifications listed in section 1.0 are presented in the following subsections. These limits have been developed using the NRC approved methodologies specified in the Technical Specifications Section 5.9.5.

The following abbreviations are used in this section:

BOL -- Beginning of Cycle Life ARO -- All Rods Out HZP -- Hot Zero Thermal Power EOL -- End of Cycle Life RTP -- Rated Thermal Power Unit 1 Cycle 7 WATTS BAR Page 2 of 18 Revision I

COLR for Watts Bar Unit 1, Cycle 7 2.1 MODERATOR TEMPERATURE COEFFICIENT - MTC (LCO 3.1.4) 2.1.1 The MTC limits are:

The BOLUAROIHZP - MTC shall be less positive than or equal to 0 Ak/c1°F (upper limit). With the measured BOUARO/HZP - MTC more positive than

-0.80 x 10' Ak/k-/JF (as-measured MTC limit), establish. control rod withdrawal limits to ensure the MTC remains less positive than or equal to 0 Ak/k/JF (upper limit) for all times In core life.

The EOL/ARO/RTP - MTC shall be less negative than or equal to

-4.5 x 10' Ak/k/0 F (lower limit).

2.1.2 The 300 ppm surveillance limit is:

The measured 300 ppm /ARO/RTP-MTC should be less negative than or equal to

-3.75 x 104 Ak/k/OF.

2.1.3 The 60 ppm surveillance limit is:

The measured 60 ppm /ARO/RTP-MTC should be less negative than or equal to

-4.28 x 104 Ak/k/ 0F.

2.2 SHUTDOWN BANK INSERTION LIMITS (LCO 3.1.6) 2.2.1 The shutdown banks shall be withdrawn to a position greater than or equal to 225 steps withdrawn.

2.3 CONTROL BANK INSERTION LIMITS (LCO 3.1.7) 2.3.1 The control banks shall be limited in physical insertion as shown in Figure 1.

2.3.2 Table 1 shows the control rod overlap positions.

Unit I Cycle 7 WATTS BAR Page 3 of 18 Revision 1

COLR for Watts Bar Unit 1, Cycle 7 2.4 HEAT FLUX HOT CHANNEL FACTOR - FQ(Z) (LCO 3.2.1)

FO(Z) < [CFQ/P]

  • K(Z) for P >0.5 FQ(Z) * [CFQ/ 0.5]
  • K(Z) for P 5 0.5 Where P = Thermal Power / Rated Thermal Power 2.4.1 CFQ = 2.50 2.4.2 K(Z) is provided in Figure 2.

2.4.3FQC(Z) =FQM(Z)

  • 1.0815 where: FQM(Z) is the measured value of FQ(Z) obtained from incore flux map results and 1.0815 is a factor that accounts for fuel manufacturing tolerances and flux map measurement uncertainty.

2.4.4 FQ'v(Z) = FQC(Z)

  • W(Z) where: W(Z) values are provided in Figures 4 through 7. The figures provide sufficient information to determine W(Z) versus core height for all cycle burnups.

2.4.5 FQw(Z) Penalty Factor The FQw(Z) penalty factor is provided In Table A.1.

Unit 1 Cycle 7 WATTS BAR Page 4 of 18 Revision 1

COLR for Watts Bar Unit 1, Cycle 7 2.5 NUCLEAR ENTHALPY RISE HOT CHANNEL FACTOR - Fw1 N (LCO 3.2.2)

FAH

  • F61RTP (I + PF * (l-P))

where P = Thermal Power / Rated Thermal Power Fu,^w = 1.65 for RFA-2 fuel, and FmH'P = 1.62 for VANTAGE+/PERFORMANCE+ fuel PF =0.3 2.6 AXIAL FLUX DIFFERENCE -AFD (LCO 3.2.3) 2.6.1 The AFD limits for Cycle 7 are provided in Figure 3.

2.7 REFUELING BORON CONCENTRATION (LCO 3.9.1) 2.7.1 The refueling boron concentration shall be 2 2000 ppm.

2.8 ACCUMULATORS (LCO 3.5.1) 2.8.1 There are 240 tritium producing burnable absorber rods (TPBARs) in the reactor core for Cycle 7.

2.9 REFUELING WATER STORAGE TANK - RWST (LCO 3.5.4) 2.9.1 There are 240 tritium producing burnable absorber rods (TPBARs) in the reactor core for Cycle 7.

Unit I Cycle 7 WATTS BAR Page 5 of 18 Revision 1

COLR for Watts Bar Unit 1, Cycle 7 250 III I fill I IIII fail (0.074, 231 225 j0:68,'22 200 4444,BANKB I HH i H H [A HH i H! i Ili i if i i i if

. .1. . . .L .F. . .H. . . . . . . . . .F.1. . ...

175 51111ITTII X m +T11 'IO-T

__ _ _01 f _ __ __ _ l l(l 1 t l l 150

/  ! l IIIIIII IIII 0

125 z

F- ___ __ _ W&, & & _ _ _1 00[1 lV z .1111 1111 LSI 1111 z 100 l'

0 m-0 cc rc 75 Z [I77, 11,1, 50 25 0

0 0.20 0.40 0.60 0.80 1.00 FRACTION OF RATED THERMAL POWER Figure 1 Control Bank Insertion Limits Versus Thermal Power Four Loop Operation

  • Fully withdrawn region shall be the condition where shutdown and control banks are at a position within the interval of 2 225 and < 231 steps withdrawn.

Unit 1 Cycle 7 WATTS BAR Page 6 of 18 Revision 1

COLR for Watts Bar Unit 1, Cycle 7 1.2 -

1.1 -

1.0 _

0.9 -

0.8 I-a) 0 0.7 cs LL 0.6 _

N CZm 0.5 0

z 0.4 _

0.3 _

0.2 _

0.1 _

0 0 2 4 6 8 10 12 Core Height (feet)

Figure 2 K(Z) - Normalized FQ(Z) as a Function of Core Height Unit I Cycle 7 WATTS BAR Page 7 of 18 Revision I

COLR for Watts Bar Unit 1, Cycle 7 120 110

['12, 100) ] (6 0)_

-I 100 90 ==;/ I AI ====tiI

/ra_ CFeai n 80 0

CL 70 I II a) 60 w

a: 50 0

-0I 40

. I I I 30 I I I 20 10 v

-50 -40 -30 -20 -10 0 10 20 30 40 50 Flux Difference (Al) %

Figure 3 Axial Flux Difference Acceptable Operation Limits as a Function of Rated Thermal Power (RAQC)

Unit I Cycle 7 WATTS BAR Page 8 of 18 Revision 1

COLR for Watts Bar Unit 1, Cycle 7 Height Max.

(feet) W(z) 0.0000 1.0000 1.40 i ..................... ...... 0.2000 1.0000 0.4000 1.0000

.. . . 1 . 1 . . . 1 . 1 . 1 . 1 . 1 . 1 . 1 . . . . . 1- 11. . . . . . . . . . . . . . 0.6000 1.0000 0.8000 1.0000 1.0000 1.0000 I I I I I I I I. II I I I I I. I.. I I.

1.2000 1.2512 1.4000 1.2321 IM Mll i !M! MIMIMlllll ll 1 M M M M!!l 1.6000 1.8000 1.2157 1.1981 2.0000 1.1793 2.2000 1.1605 1.30 1111111111111111111111111111111111111111 2.4000 1.1410 2.6000 1.1210 11I I I I I I I I Ia I I I I Ia M11MMIMMIiMM1111 I Ia1111111! lll I I I I I Ia I aI I.AFF 1.11 1I I I I I ri I I I aI iI MM11111 M1III11 I I I I 2.8000 3.0000 1.1104 1.1052 3.2000 1.1019 I. . . . . . . . . . . . . . . . . . . . . . . . . . . s.. . . . . .- - - - - - - - - - - - - 1 3.4000 1.1008 3.6000 1.0998 I 111. . . . . . . . . . . . . . . ... I I. I 1 II 1 11 1 3.8000 1.1001 4.0000 1.1036 I I . I I I. I I .1 1-

. 1 . 1. . . . 1 1.1l

. 1.1 . . . . . . . . 1 .1 .1 1 1.

4.2000 1.1088 4.4000 1.1132 N 3 4.6000 1.1173

.2 .. 111 .. .. Wl . 11 1111 . .1111-. 11.1 1111

.- . .111.... 11 1.1206 4.8000 I 5.0000 1.1251 5.2000 1.1349 11 Ill11111 IllII I l N11Illi11 111111 11 ill Ill I 5.4000 5.6000 5.8000 6.0000 1.1503 1.1648 1.1804 1.1972 6.2000 1.2135 1l111MMMM1111M11111111M11MMM111111 6.4000 1.2283 6.6000 1.2416

.I . . . . . . . . 6.8000 1.2531 7.0000 1.2627

.I 111111111111111 Illllli1111111111111111111 7.2000 1.2703 7.4000 1.2756 7.6000 1.2786

.111111 11111111111111..1111111111111..111 7.8000 1.2789 8.0000 1.2765 III II I 1 11111 11 I I I III I.I.I I..I. III I. I... 8.2000 1.2714 8.4000 1.2633 II 111 ill II II 1111 I 11111111 111111 11111 111 8.6000 1.2515 II I-I I- - - - - - - - -.1 11- - - - - - -

8.8000 1.2402 9.0000 1.2362 i1.0 ................. ...........................

9.2000 1.2376 0 1 2 3 4 5 6 7 8 9 10 II 32 9.4000 1.2404 BOTTOM TOP 9.6000 1.2392 CORE HEIGHT (FEET) 9.B000 1.2345 10.0000 1.2327 10.2000 1.2381 10.4000 1.2446 10.6000 1.2503 10.8000 1.2541 Figure 4 11.0000 1.0000 11.2000 1.0000 RAOC Summary of Max W(z) at 150 MWDIMTU 11.4000 1.0000 with HFP AFD Band of -12/+6 % 11.6000 1.0000 11.8000 1.0000 (Top and Bottom 10% Excluded) 12.0000 1.0000 Unit 1 Cycle 7 WATTS BAR Page 9 of 18 Revision 1

COLR for Watts Bar Unit 1, Cycle 7 Height Max.

(feet) W(z) 0.0000 1.0000 1.4 Of 0.2000 1.0000 I I. . . . . 1.

1. . 1.1 1. 1 1. 1 1. 1 1. 1. . 1. . 1. . 1. 1 1111111111 1 1 1 1 0.4000 1.0000 0.6000 1.0000 0.8000 1.0000

.. . . .. . . .. . . . ......................... 111 1§1 151 111 1.0000 1.0000 1.2000 1.2569 1.4000 1.2421 111111111111111111111111111111111111111111111111 1.6000 1.2249 llI((IIIIl IMATW0e 1.8000 1.2063 2,0000 1.1868 2.2000 1.1669

1. 3t ] 1 1g711i1] 11t 2.4000 1.1466 2.6000 1.1261 111711 ITlililill 111 ITt IlililF711111177715177711 2.8000 1.1120 ITI r n n m milTn nTTlT1rrTT I n n nm 14111 m 3.0000 1.1040

. 11 I m I I Tn rTHr 1rTrill I XTTb maTT 3.2000 1.1003

. 1L1 : 1 llT 1 I 11111111Innn 1 Illn 3.4000 1.0993 3.6000 1.0983 3.8000 1.1000

X2 i fflt++ITIllMl fme 4.0000 1.1033

. II ff I I 11177711117tl 111 I THm 4.2000 1.1059 Ll I 111 1 I I lilITIIll 1?:10 I 1 1 lXllf ITIfFICL N

1. .21 - :11 X w

.:1;

; 111 111111r17, ; ; 1X

... IIIII.II ll 111 l

+

4.4000 4.6000 4.8000 5.0000 1.1083 1.1103 1.1122 1.1130 5.2000 1.1151

+. § § F + . +I I . I : I I.I; 1; 1 .........  : 5.4000 1.12i6 5.6000 1.1378 5.8000 1.1516

+. t i I II .1 I I I I II II I II II I II I I I I 6.0000 1.1666 6.2000 1.1814 6.4000 1.1950 1~1 J.I14tTIX4

.. . . . 1.. .w . .t ........

ii t t ... . . 6.6000 6.8000 7.0000 7.2000 1.2072 1.2181 1.2273 1.2350 7.4000 1.2417 7.6000 1.2468 7.8000 1.2498 8.0000 1.2506 8.2000 1.2491 8.4000 1.2452 8.6000 1.2385 8.8000 1.2314 1.001_0 1 2 3 4 f 5 ff 6 7 8 9 10 11 12 9.0000 9.2000 9.4000 1.2310 1.2388 1.2458 BOTTOM TOP 9.6000 1.2527 CORE HEIGHT (FEET) 9.8000 1.2629 10.0000 1.2754 10.2000 1.2870 10.4000 1.2973 10.6000 1.3059 10.8000 1.3123 Figure 5 11.0000 1.0000 RAOC Summary of Max W(z) at 3000 MWDJMTU 11.2000 1.0000 11.4000 1.0000 with HFP AFD Band of -12/+6 % 11.6000 1.0000 11.8000 1.0000 (Top and Bottom 10% Excluded) 12.0000 1.0000 Unit 1 Cycle 7 WVAiTS BAR Page 10 of 18 Revision 1

COLR for Watts Bar Unit 1, Cycle 7.

Height Max.

(feet) IV(z) 0.0000 1.0000 I IlI II I I I I I I I I I I I II I I 0.2000 1.0000 1.40 I III I I I 0.4000 1.0000 0.6000 1.0000 0.8000 1.0000 1.0000 1.0000 lLAHL LlTUT L 1.2000 1.4000 1.2850 1.2734 g4X W lilTllT Jliili1-1IT1l 1.6000 1.8000 1.2595 1.2441 X4 04X MII~ITIIIHTIIIII 2.0000 2.2000 1.2279 1.2112 3t 4n- _igiE_.itE4 _ _ ._. 2.4000 1.1941 2.6000 1.1768 2.8000 1.1588 rTITiT1 Ti hl I _i .111 ri T IT T 1:1 ____I 3.0000 1.1486 3.2000 1.1459 r _T r T T.... _.r.T...T._._._._.. _._._._._...... I I.. 3.4000 1.1426 3.6000 1.1388 3.8000 1.1349

. i gi ii iR i. .. .. 4.0000 4.2000 1.1319 1.1305 4.4000 1.1302

...t._.t t.t

. ... tt .. t

._..t t. ..

_. l 4.6000 1.1291 N 1.20 4.8000 1.1287 ii ii .. hi. :11 ii iiiiii :1 . i - ..... ii .... ... 5.0000 1.1281 5.2000 1.1291 5.4000 1.1391 5.6000 1.1495

. tt

... . _. . _. . . . ._.. . 5.8000 1.1589

. t . _t. .t . . .r. . . . .

6.0000 1.1673 6.2000 1.1746 in :III 6.4000 1.1806

i n i InzIn niE fn nIn: : n:n:n:nn 6.6000 1.1854

. ttttll.ttttt. ... _. ................ 6.8000 7.0000 1.1887 1.1910

.I tI _ 1 t ..1t i: t ii -.jl - 11tI tl:  : t._._.

._. 7.2000 1.1925 7.4000 1.1928 1.1914

.11 11 lII I I ll 111I jIllI I ill ll 111ll 7.6000 7.8000 1.1883 8.0000 1.1833

. . . . . . .. . ... . . . . . . 1 . . .. 1 . . .  : . . .. . 8.2000 1.1767 8.4000 1.1702

.. - ... t t ... _vt ... - t ...t t... t- I............. 8.6000 1.1654 8.8000 1.1637 9.0000 1.1644 noI .I.

_ . C I.!!!!II s H . _

11 1111 1III 11111 1I11I1!1111 1 III iI 1ili

,L1

_E 9.2000 1.1690 0

1 2 3 4 5 6 7 8 9 10 11 12 9.4000 1.1717 BOTTOM TOP 9.6000 1.1730 CORE HEIGHT (FEET) 9.8000 1.1720 10.0000 1.1708 10.2000 1.1708 10.4000 1.1688 10.6000 1.1665 10.8000 1.1659 Figure 6 11.0000 1.0000 11.2000 1.0000 RAOC Summary of Max W(z) at 10000 MWD/MTU 11.4000 1.0000 with HFP AFD Band of -124+6 % 11.6000 1.0000 11.8000 1.0000 (Top and Bottom 10% Excluded) 12.0000 1.0000 Unit 1 Cycle 7 WATTS BAR Page ll of 18 Revision 1

COLR for Watts Bar Unit 1, Cycle 7 Height Max.

(feet) W(z) 0.0000 1.0000 1.40j 0.2000 1.0000

........................ 1

............ -------- 0.4000 1.0000 0.6000 1.0000 I

I I I I I I I I. I.II.II.II.II.II II II II I I I I I I .1- 1 0.8000 1.0000 1.0000 1.0000 1.2000 1.2430 MiMMM I 111111111111 MMM ....... 1.4000 1.6000 1.8000 1.2337 1.2227 1.2108 2.0000 1.1986 2.2000 t.30 ........ 2.4000 1.1862 1.1735 2.6000 1.1606

.I... . . .. . . . . .. .. . .. . ... . .. . -

2.8000 1.1514 I 3.0000 1.1495 II II I IIII I IIIII I I I.II I II I III IIIT III 3.2000 3.4000 1.1518 1.1525 3.6000 1.1528 I FF ~~~. . ._. ..........

_.___. .... I..-11...II 3.8000 1.1566 4.0000 1.1621 1

..... .. _....III.. 4.2000 1.1661 I11-

. _..._._._... 4.4000 1.1693 ts1.203 ____._ _t5 - lTT 4.6000 4.8000 1.1715 1.1729 I I 4 z 1 1111 M 5.0000 5.2000 1.1731 1.1753 5.4000 1.1880 5.6000 1.1985 5.8000 1.2070 6.0000 1.2142 6.2000 1.2196 6.4000 1.2234 6.6000 1.2254 6.8000 1.2256 1.310 - 4_ _TX 7.0000 1.2247 7.2000 1.2229 7.4000 1.2190 7.6000 1.2130 7.8000 1.2053 8.0000 1.1951 8.2000 1.1845 8.4000 1.1773 8.6000 1.1701 8.8000 1.1651

.4 . . . . . .. '1111111111 9.0000 1.1598 1.001 I 9.2000 1.1547 0 1 2 3 5 6 7 8 9 10 11 12 9.4000 1.1571 BOT~TOM TOP 9.6000 1.1614 CORE HEIGHT (FEET) 9.8000 1.1653 10.0000 1.1686 10.2000 1.1727 10.4000 1.1781 10.6000 1.1829 10.8000 1.1845 Figure 7 11.0000 1.0000 RAOC Summary of Max W(z) at 16000 MWD/MTU 11.2000 1.0000 11.4000 1.0000 with HFP AFD Band of -12/+6 % 11.6000 1.0000 11.8000 1.0000 (Top and Bottom 10% Excluded) 12.0000 1.0000 Unit 1 Cycle 7 WATTS BAR Page 12 of 18 Revision 1

COLR for Watts Bar Unit 1, Cycle 7 Table A.1 FQW(Z) Penalty Factor Core FQW(Z2) 3urnup Penalty (MWDMr Factor All burnups 1.0200 Note:

1. The Penalty Factor, which Is applied to FQ'(Z) for compliance with Surveillance Requirement 3.2.1.2.a, is the maximum factor by which FQ',(Z) is expected to increase per 31 Effective Full Power Days (EFPD) starting from the burnup at which the FQW(Z) was determined.

Unit 1 Cycle 7 WATTS BAR Page 13 of 18 Revision 1

I COLR for Watts Bar Unit 1, Cycle 7 Table 1: Control Rod Overlap Band A Bank B Bank C Bank D Bank Band A Bank B Bank C Bank D Bank Overlap Overlap Counter Counter (steps) (steps) 72 ___

0 0 72 72 2 2 74 74 4 4 76 76 6 6 78 78 8 8 80 80 10 10 82 82 12 12 84 84 14 14 86 86 16 16 88 88 18 18 90 90 20 20 92 92 22 22 94 94 24 24 96 96 26 26 98 98 28 28 100 100 30 30 102 102 32 32 104 104 34 34 106 106 36 36 108 108 38 38 110 110 40 40 112 112 42 42 114 114 44 44 116 116 46 46 118 118 48 48 120 120 50 50 122 122 52 52 124 124 54 54 126 126 56 56 128 128 0 58 58 130 130 2 60 60 132 132 4 62 62 134 134 6 64 64 136 136 8 66 66 138 138 10 68 68 140 140, 12 70 70 142 142 14 Unit 1 Cycle 7 WATTS BAR Page.14 of 18 Revision 1

COLR for Watts Bar Unit 1, Cycle 7 Table 1: Control Rod Overlap Band A Bank B Bank C Bank D Bank Band A Bank B Bank C Bank D Bank Overlap Overlap Counter Counter (steps) (steps) 144 144 16 220 220 92 146 146 18 222 222 94 148 148 20 224 224 96 150 150 22 226 226 98 152 152 24 228 228 100 154 154 26 230 230 102 156 156 28 232 232 104 158 158 30 234 106 160 160 32 236 108 162 162 34 238 110 164 164 36 240 112 166 166 38 242 114 168 168 40 244 116 170 170 42 246 118 172 172 44 248 120 174 174 46 250 122 176 176 48 252 124 178 178 50 254 126 180 180 52 256 128 0 182 182 54 258 130 2 184 184 56 260 132 4 186 186 58 262 134 6 188 188 60 264 136 8 190 190 62 266 138 10 192 192 64 268 140 12 194 194 66 270 142 14 196 196 68 272 144 16 198 198 70 274 146 18 200 200 72 276 148 20 202 202 74 278 150 22 204 204 76 280 152 24 206 206 78 282 154 26 208 208 80 284 156 28 210 210 82 286 158 30 212 212 84 288 160 32 214 214 86 290 162 34 216 216 88 292 164 36 218 218 90 294 166 38 Unit 1 Cycle 7 WATTS BAR Page 15 of 18 Revision 1

COLR for Watts Bar Unit 1, Cycle 7 Table 1: Control Rod Overlap Band A Bank B Bank C Bank D Bank Band A Bank B Bank C Bank D Bank Overlap Overlap Counter Counter (steps) (steps) _

296 168 40 370 1 114 298 170 42 372 116 300 172 44 374 118 302 174 46 376 120 304 176 48 378 122 306 178 50 380 124 308 180 52 382 126 310 182 54 384 128 0 312 184 56 386 130 2 314 186 58 388 132 4 316 188 60 390 134 6 318 190 62 392 136 8 320 192 64 394 138 10 322 194 66 396 140 12 324 196 68 _ 398 142 14 326 198 70 400 144 16 328 200 72 402 146 18 330 202 74 404 148 20 332 204 76 406 150 22 334 206 78 408 152 24 336 208 80 410 154 26 338 210 82 412 156 28 340 212 84 414 158 30 342 214 86 416 160 32 344 216 88 418 162 34 346 218 90 420 164 36 348 220 92 422 166 38 350 222 94 424 168 40 352 224 96 426 170 42 354 226 98 428 172 44 356 228 100 430 174 46 358 230 102 432 176 48 360 232 104 434 178 50 362 106 436 180 52 364 108 438 182 54 366 110 440 184 56 368 112 442 186 58 Unit 1 Cycle 7 WATITS BAR Page 16 of 18 Revision I

COLR for Watts Bar Unit 1, Cycle 7 Table 1: Control Rod Overlap Band A Bank B Bank C Bank D Bank Band A Bank B Bank C Bank D Bank Overlap Overlap Counter Counter (steps) (steps) 134 444 188 60 518 134 446 190 62 520 136 448 192 64 522 138 450 194 66 524 140 452 196 68 526 142 454 198 70 528 144 456 200 72 530 146 458 202 74 532 148 460 204 76 534 150 462 206 78 536 152 464 208 80 538 154 466 210 82 540 156 468 212 84 542 158 470 214 86 544 160 472 216 88 546 162 474 218 90 548 164 476 220 92 550 166 478 222 94 552 168 480 224 96 554 170 482 226 98 556 172 484 228 100 558 174 486 230 102 560 176 488 232 104 562 178 490 106 564 -180 492 108 566 182 494 110 568 184 496 112 570 186 498 114 572 188 500 116 574 190 502 118 576 192 504 120 578 194 506 122 580 196 508 124 582 198 510 126 584 200 512 128 586 202 514 130 588 204 516 132 590 206 Unit 1 Cycle 7 WATTS BAR Page 17 of 18 Revision 1

COLR for Watts Bar Unit 1, Cycle 7 Table 1: Control Rod Overlap Band A Bank B Bank C Bank D Bank Overlap Counter (steps) 592 208 594 210 596 212 598 214 600 216 602 218 604 220 606 222 608 224 610 226 612 228 614 230 616 232 This information is provided in 2 step increments. One step increments can be derived by interpolation. Fully withdrawn region shall be the condition where shutdown and control banks are at a position within the interval of 2225 and *231 steps withdrawn. The Table indicates a maximum step of 232 to be consistent with 2 step increments.

Unit 1 Cycle 7 WAITS BAR Page 18 of 18 Revision 1