U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Gentlemen:
In the Matter of the
)
Docket No. 50-390 Tennessee Valley Authority
)
WATTS BAR NUCLEAR PLANT (WBN) UNIT 1 - CORE OPERATING LIMITS REPORT (COLR) FOR CYCLE 9, REVISION 0 The purpose of this letter is to provide Revision 0 of the Cycle 9 COLR in accordance with WBN Technical Specification 5.9.5.d. This revision was effective as of March 5, 2008.
There are no regulatory commitments associated with this submittal. If you have any questions concerning this letter, please contact me at (423) 365-1824.
Sincerely, M. K. Brandon Manager, Site Licensing and Industry Affairs
Enclosure:
Watts Bar Nuclear Plant Unit 1, Cycle 9 Core Operating Limits Report, Revision 0 cc: See Page 2 March 12, 2008 Original signed by C. Riedl for
U.S. Nuclear Regulatory Commission Page 2 Enclosure cc (Enclosure):
NRC Resident Inspector Watts Bar Nuclear Plant 1260 Nuclear Plant Road Spring City, Tennessee 37381 ATTN: Margaret H. Chernoff, Senior Project Manager U.S. Nuclear Regulatory Commission Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation MS O-8 H4-A Washington, DC 20555-0001 U.S. Nuclear Regulatory Commission Region II Sam Nunn Atlanta Federal Center 61 Forsyth St., SW, Suite 23T85 Atlanta, Georgia 30303 March 12, 2008
Enclosure Watts Bar Nuclear Plant Unit 1 Cycle 9 Core Operating Limits Report, Revision 0
COLR for Watts Bar Unit 1, Cycle 9 Unit 1 Cycle 9 WATTS BAR Page 2 of 10 Revision 0 1.0 CORE OPERATING LIMITS REPORT This Core Operating Limits Report (COLR) for Watts Bar Unit 1 Cycle 9 has been prepared in accordance with the requirements of the Technical Specifications 5.9.5.
The Technical Specifications affected by this report are listed below:
3.1.4 Moderator Temperature Coefficient (MTC) 3.1.6 Shutdown Bank Insertion Limits 3.1.7 Control Bank Insertion Limits 3.2.1 Heat Flux Hot Channel Factor (FQ(Z))
3.2.2 Nuclear Enthalpy Rise Hot Channel Factor (F'H N) 3.2.3 Axial Flux Difference (AFD) 3.5.1 Accumulators 3.5.4 Refueling Water Storage Tank (RWST) 3.9.1 Boron Concentration 2.0 OPERATING LIMITS The cycle-specific parameter limits for the specifications listed in section 1.0 are presented in the following subsections. These limits have been developed using the NRC approved methodologies specified in the Technical Specifications Section 5.9.5.
The following abbreviations are used in this section:
BOL Beginning of Cycle Life ARO All Rods Out HZP Hot Zero Thermal Power EOL End of Cycle Life RTP Rated Thermal Power
COLR for Watts Bar Unit 1, Cycle 9 Unit 1 Cycle 9 WATTS BAR Page 3 of 10 Revision 0 2.1 MODERATOR TEMPERATURE COEFFICIENT - MTC (LCO 3.1.4) 2.1.1 The MTC limits are:
The BOL/ARO/HZP - MTC shall be less positive than or equal to 0 'k/k/qF (upper limit). With the measured BOL/ARO/HZP - MTC more positive than -1.00 x 10-5
'k/k/qF (as-measured MTC limit), establish control rod withdrawal limits to ensure the MTC remains less positive than or equal to 0 'k/k/qF (upper limit) for all times in core life.
The EOL/ARO/RTP - MTC shall be less negative than or equal to
-4.5 x 10-4 'k/k/qF (lower limit).
2.1.2 The 300 ppm surveillance limit is:
The measured 300 ppm /ARO/RTP-MTC should be less negative than or equal to
-3.75 x 10-4 'k/k/qF.
2.1.3 The 60 ppm surveillance limit is:
The measured 60 ppm /ARO/RTP-MTC should be less negative than or equal to
-4.28 x 10-4 'k/k/qF.
2.2 SHUTDOWN BANK INSERTION LIMITS (LCO 3.1.6) 2.2.1 The shutdown banks shall be withdrawn to a position greater than or equal to 225 steps withdrawn.
2.3 CONTROL BANK INSERTION LIMITS (LCO 3.1.7) 2.3.1 The control banks are fully withdrawn or shall be limited in physical insertion as shown in Figure 1.
2.3.2 Each control bank shall be considered fully withdrawn from the core at greater than or equal to 225 steps.
COLR for Watts Bar Unit 1, Cycle 9 Unit 1 Cycle 9 WATTS BAR Page 4 of 10 Revision 0 2.3.3 The control banks shall be operated in sequence by withdrawal of Bank A, Bank B, Bank C, and Bank D. The control banks shall be sequenced in reverse order upon insertion.
2.3.4. Each control bank not fully withdrawn from the core shall be operated with the following overlap as a function of park position.
Park Position (steps)
Bank Overlap (steps)
Bank Difference(steps) 225 109 116 226 110 116 227 111 116 228 112 116 229 113 116 230 114 116 231 115 116 2.4 HEAT FLUX HOT CHANNEL FACTOR - FQ(Z) (LCO 3.2.1)
FQ(Z) d [CFQ / P]
- K(Z) for P > 0.5 FQ(Z) d [CFQ / 0.5]
- K(Z) for P d 0.5 Where P = Thermal Power / Rated Thermal Power 2.4.1 CFQ = 2.50 2.4.2 K(Z) is provided in Figure 2.
2.4.3 FQ C(Z) = FQ M(Z)
- 1.0815 where: FQ M(Z) is the measured value of FQ(Z) obtained from incore flux map results and 1.0815 is a factor that accounts for fuel manufacturing tolerances and flux map measurement uncertainty.
2.4.4 FQ W(Z) = FQ C(Z)
- W(Z) where: W(Z) values are provided in Table A.1. The table provides sufficient information to determine W(Z) versus core height for all cycle burnups.
COLR for Watts Bar Unit 1, Cycle 9 Unit 1 Cycle 9 WATTS BAR Page 5 of 10 Revision 0 2.4.5 FQ W(Z) Penalty Factor The FQ W(Z) penalty factor is provided in Table A.2.
2.5 NUCLEAR ENTHALPY RISE HOT CHANNEL FACTOR - F'H N (LCO 3.2.2)
F'H N d F'H RTP * ( 1 + PF * ( 1-P))
where P = Thermal Power / Rated Thermal Power F'H RTP = 1.65 for RFA-2 fuel, and PF = 0.3 2.6 AXIAL FLUX DIFFERENCE - AFD (LCO 3.2.3) 2.6.1 The AFD limits for Cycle 9 are provided in Figure 3.
2.7 REFUELING BORON CONCENTRATION (LCO 3.9.1) 2.7.1 The refueling boron concentration shall be t 2000 ppm.
2.8 ACCUMULATORS (LCO 3.5.1) 2.8.1 There are 368 tritium producing burnable absorber rods (TPBARs) in the reactor core for Cycle 9.
2.9 REFUELING WATER STORAGE TANK - RWST (LCO 3.5.4) 2.9.1 There are 368 tritium producing burnable absorber rods (TPBARs) in the reactor core for Cycle 9.
COLR for Watts Bar Unit 1, Cycle 9 Unit 1 Cycle 9 WATTS BAR Page 6 of 10 Revision 0 (0.0, 180)
(0.197, 225)
(0.703, 225)
(0.0, 64)
(1.0, 177)
(0.227, 0)
BANK D BANK C BANK B 0
25 50 75 100 125 150 175 200 225 250 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 FRACTIONAL OF RATED THERMAL POWER ROD BANK STEP POSITION (STEPS WITHDRAWN)
Figure 1 Control Bank Insertion Limits Versus Thermal Power Four Loop Operation Fully withdrawn region shall be the condition where shutdown and control banks are at a position within the interval of t 225 and d 231 steps withdrawn.
COLR for Watts Bar Unit 1, Cycle 9 Unit 1 Cycle 9 WATTS BAR Page 7 of 10 Revision 0 Figure 2 K(Z) - Normalized FQ(Z) as a Function of Core Height 0
2 4
6 8
10 12 0
0.2 0.4 0.1 0.3 0.5 0.6 0.7 0.9 1.1 0.8 1.0 1.2 Core Height K(Z) 0.000 1.000 6.000 1.000 12.000 0.9256 Core Height (feet)
Normalized FQ
- Power
COLR for Watts Bar Unit 1, Cycle 9 Unit 1 Cycle 9 WATTS BAR Page 8 of 10 Revision 0 Figure 3 Figure 3 Axial Flux Difference Acceptable Operation Limits as a Function of Rated Thermal Power (RAOC) 0 10 20 30 40 50 60 70 80 90 100 110 120
-50
-40
-30
-20
-10 0
10 20 30 40 50 Flux Difference ('I) %
% of Rated Thermal Power (7, 100)
(-12, 100)
(-28, 50)
Unacceptable Operation Acceptable Operation (21, 50)
Unacceptable Operation
COLR for Watts Bar Unit 1, Cycle 9 Unit 1 Cycle 9 WATTS BAR Page 9 of 10 Revision 0 Table A.1 FQ W(Z) = FQ C(Z)
- W(Z)
Height (ft)
Max W(z) at 150 MWD/MTU Max W(z) at 2000 MWD/MTU Max W(z) at 4000 MWD/MTU Max W(z) at 10000 MWD/MTU Max W(z) at 18000 MWD/MTU 12.0000 1.0000 1.0000 1.0000 1.0000 1.0000 11.8000 1.0000 1.0000 1.0000 1.0000 1.0000 11.6000 1.0000 1.0000 1.0000 1.0000 1.0000 11.4000 1.0000 1.0000 1.0000 1.0000 1.0000 11.2000 1.0000 1.0000 1.0000 1.0000 1.0000 11.0000 1.0000 1.0000 1.0000 1.0000 1.0000 10.8000 1.3158 1.3647 1.3317 1.2020 1.1787 10.6000 1.3136 1.3556 1.3261 1.1932 1.1745 10.4000 1.3103 1.3436 1.3177 1.1854 1.1703 10.2000 1.3090 1.3295 1.3089 1.1793 1.1644 10.0000 1.3033 1.3142 1.2978 1.1723 1.1600 9.8000 1.2973 1.2965 1.2842 1.1678 1.1558 9.6000 1.2904 1.2817 1.2710 1.1641 1.1555 9.4000 1.2801 1.2715 1.2619 1.1604 1.1590 9.2000 1.2679 1.2609 1.2571 1.1592 1.1620 9.0000 1.2575 1.2502 1.2509 1.1584 1.1728 8.8000 1.2542 1.2447 1.2475 1.1628 1.1843 8.6000 1.2550 1.2454 1.2475 1.1741 1.2001 8.4000 1.2601 1.2480 1.2471 1.1861 1.2220 8.2000 1.2620 1.2479 1.2438 1.1970 1.2399 8.0000 1.2619 1.2460 1.2381 1.2057 1.2553 7.8000 1.2597 1.2422 1.2319 1.2121 1.2682 7.6000 1.2554 1.2367 1.2282 1.2164 1.2781 7.4000 1.2491 1.2293 1.2269 1.2184 1.2851 7.2000 1.2409 1.2203 1.2228 1.2183 1.2893 7.0000 1.2341 1.2131 1.2168 1.2161 1.2906 6.8000 1.2283 1.2067 1.2095 1.2125 1.2892 6.6000 1.2214 1.1991 1.2007 1.2074 1.2850 6.4000 1.2123 1.1896 1.1902 1.2006 1.2783 6.2000 1.2016 1.1785 1.1782 1.1921 1.2691 6.0000 1.1915 1.1699 1.1688 1.1816 1.2573 5.8000 1.1816 1.1610 1.1589 1.1721 1.2437 5.6000 1.1725 1.1518 1.1485 1.1649 1.2268 5.4000 1.1644 1.1457 1.1417 1.1587 1.2095 5.2000 1.1560 1.1425 1.1395 1.1538 1.2027 5.0000 1.1520 1.1405 1.1380 1.1522 1.2031 4.8000 1.1500 1.1384 1.1369 1.1539 1.2041 4.6000 1.1470 1.1354 1.1360 1.1593 1.2030 4.4000 1.1433 1.1319 1.1343 1.1633 1.2009 4.2000 1.1390 1.1277 1.1321 1.1669 1.1975 4.0000 1.1342 1.1233 1.1296 1.1703 1.1936 3.8000 1.1287 1.1179 1.1265 1.1727 1.1876 3.6000 1.1243 1.1142 1.1252 1.1765 1.1841 3.4000 1.1225 1.1136 1.1285 1.1847 1.1874 3.2000 1.1261 1.1164 1.1336 1.1928 1.1902 3.0000 1.1289 1.1259 1.1411 1.2001 1.1986 2.8000 1.1405 1.1423 1.1574 1.2160 1.2086 2.6000 1.1631 1.1622 1.1811 1.2403 1.2199 2.4000 1.1858 1.1829 1.2040 1.2628 1.2384 2.2000 1.2086 1.2057 1.2271 1.2851 1.2564 2.0000 1.2313 1.2286 1.2500 1.3069 1.2736 1.8000 1.2528 1.2507 1.2725 1.3276 1.2904 1.6000 1.2746 1.2719 1.2940 1.3470 1.3063 1.4000 1.3005 1.2912 1.3136 1.3643 1.3205 1.2000 1.3291 1.3078 1.3303 1.3785 1.3320 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 0.8000 1.0000 1.0000 1.0000 1.0000 1.0000 0.6000 1.0000 1.0000 1.0000 1.0000 1.0000 0.4000 1.0000 1.0000 1.0000 1.0000 1.0000 0.2000 1.0000 1.0000 1.0000 1.0000 1.0000 0.0000 1.0000 1.0000 1.0000 1.0000 1.0000
COLR for Watts Bar Unit 1, Cycle 9 Unit 1 Cycle 9 WATTS BAR Page 10 of 10 Revision 0 Table A.2 FQ W(Z) Penalty Factor Note:
1.
The Penalty Factor, which is applied to FQ W(Z) for compliance with Surveillance Requirement 3.2.1.2.a, is the maximum factor by which FQ W(Z) is expected to increase per 31 Effective Full Power Days (EFPD) starting from the burnup at which the FQ W(Z) was determined.
Core FQ W(Z)
Burnup Penalty (MWD/MTU)
Factor All Burnups 1.0200