W3F1-2023-0056, Owner'S Activity Report Form for Inservice Inspection Performed During Operating Cycle 24 / Refuel 24

From kanterella
Jump to navigation Jump to search
Owner'S Activity Report Form for Inservice Inspection Performed During Operating Cycle 24 / Refuel 24
ML23353A245
Person / Time
Site: Waterford Entergy icon.png
Issue date: 12/19/2023
From: Twarog J
Entergy Operations
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
W3F1-2023-0056
Download: ML23353A245 (1)


Text

entergy John Twarog Manager Regulatory Assurance 504-739-6747 W3F1 -2023-0056 December 19, 2023 Attn: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

Subject:

Owner's Activity Report Form for lnservice Inspection Performed During Operating Cycle 24 I Refuel 24 Waterford Steam Electric Station, Unit 3 Docket No. 50-382 Renewed Facility Operating License No. NPF-38

Reference:

Entergy Operations, Inc. Letter to U.S. Nuclear Regulatory Commission, "Submittal of Owner's Activity Report Form for lnservice Inspection Performed During Operation Cycle 24/Refuel 24," (ADAMS Accession No. ML22220A306), dated August 8, 2022.

In the referenced letter, Entergy Operations, Inc. (EOI) provided the Waterford Steam Electric Station, Unit 3 (WF3) Owner's Activity Report (OAR) for Operating Cycle 24/Refuel 24.

Following submittal of that letter, EOI identified components that were omitted from Table 1 (items with flaws or relevant conditions that required evaluation for continued service) of the OAR. This issue has been entered into the WF3 corrective action program. The enclosure provides a revised OAR that includes an updated Table 1 with components that did not meet the VT-3 acceptance criteria provided by ASME Section XI. These components were evaluated for acceptability in accordance with the 2007 Edition through the 2008 Addenda of ASME Section XI, Subsection IWF-3122.3. Table 2 (abstract of repair/replacement activities required for continued service) of the OAR provided in the referenced letter remains unchanged.

There are no new commitments contained in this submittal.

Please contact me at (504) 739-6747 should you have any questions regarding this submittal.

Respectfully, JT/llb Entergy Operations, Inc., 17265 River Road Killona, LA 70057-3093

W3F1-2023-0056 Page 2 of 2

Enclosure:

Updated Owner's Activity Report for lnservice Inspection Performed During Operating Cycle 24/ Refuel 24.

cc: NRC Region IV Regional Administrator NRC Senior Resident Inspector - Waterford 3 NRC Project Manager - Waterford 3 Mr. Daniel H. Wallis Office of the State Fire Marshall 8181 Independence Blvd.

Baton Rouge, LA 70806

Enclosure to W3F 1-2023-0056 Re-Submittal of Owner's Activity Report for lnservice Inspection Performed During Operating Cycle 24/Refuel 24

ATTACHMENT 7.2 Program Section No: CEP-RR-001 Page No.: l of 3 Revision No.: 318 FORM OAR-1 OWNERS ACTIVITY REPORT R eport Number: W3F l -2023-005 6 Page _!_ of _J_

Plant: __W-'-'-"a"'te,,,r' .:.;fo"'rd.,, ""'St""' e""::, n E...: l, e"" c""tr:.:.. ic"-'St"" a.,,, til°"lO...,.'"""l...7,:..:6"'5'""'R a t:.:.::.. ive

..=..:...: -=.c.._

r -=- R:.a: a=-d,_, K=-=

o:..:: i llo

"" ""'n.,_,a=1 -"L'""a"-. "-

70:c-0=5"-'7'--

Unit N o: ___,3:.----_ Commercial Service Da te: 0 9/24/1985 Refueling Outage No .: ___,2::...4,____

(if applicable)

Current Inspection Interval: __4'-th_I=S:..:I--=I= n=terv "--'a"' l'---______

( I st. 2nd. 3rd. 4th. Other)

Current Inspection Period: ___,2::..."- .,_P"" er,_,_i"'" od =--------------

( I st, 2nd, 3rd)

Edition and Addenda of Section XI applicable to the Inspection P lans: 2007 Edition Through 2008 Addenda Date and R evision of Inspection Plans: 10 /13/2021 Revision 11 of SEP-ISI-104 Edition and Addenda of Section XI applicable to repair/replacement activities, if different than the Inspection Plans:

Code Cases used for inspection and evaluation: ______,N -5:..:.3:..::2:....:-5"----------

c...:.....e (if applicable. including cases modified by Case N-532 and later revisions)

CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report arc correct; (b) the examinations and tests meet the Inspection P lan as required hy the ASME Code,Section XI; and (c) the repair/replacement activities and evaluations supporti ng the completion of R efue l 24 conform to the requ irements of Section XI.

(Refueling 01 gc number)

Signed: Seth Bratton Welding/Repair R eplacement Engineer wner or Owner's Dcsignce. Tille CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid co mmission issued hy the Nation a l Board of Boiler and Pressu re Ve ssel Inspectors and employed by The Hartford Steam Boiler Inspection and Insurance Company of Connecticut have inspected the items described in this Owner 's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represente d hy this report in accordance with the requ irements of Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expresse d or implied, conce rning the repair/ replace ment activities and evaluation described in this report. Furthermor e, neither the Inspector nor his employer shall he liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Commissions: ____1_2_0_8_5_N*l,_R_____

Date: December 08, 2023

ATTACHMENT 7.2 Program Section No: CEP-RR-001 Page No.: 2 of 3 Re,*ision No.: 318 FORM OAR-1 OWNERS ACTIVITY REPORT Report Number: W3Fl-2023-0056 Plant: Waterford Steam Electric Station. 1765 Ri\L:r Road. Killona. La. 70057 Unit No: .1, Commercial Sen ii:e Date: 09/2..J./1985 Refueling Outagi: Nll.: _H_

tif applic*ahkJ TABLE I:

1*1 EIS Wn II FI.-\\\ s OR REI.I*.\.\'.\ I' Cm,llITIOS TII-\T RE(Jl'IREI> E\' \l.l'-\'I'IO'i ['()I{ CoSTISl'l*,ll SE In ICE b.aminalion Item De,i:riplion I:\ aluatinn Dccription Category and 11..:m Number F-A f-UOA CCRR-mn., RIGID RESTRAINT EC lJ2738 l'\'aluated the ,upport a" an:eptahll' 10 rl'main in ,en*i..:e.

ReferetH.:e \V -ISI-EV-22-006 F-A FUOB ACR-1027 RIGID RESTRAINT EC 9276..J. e\ aluatecl the suppnrt a acceplahle to remain in ,en ice.

Reference W-ISI-EY-22-!Hl.5 F-A F l.30;\ ACR-106-t RIGID RESTRAINT EC LJ2775 e, aluated the ,upport a-. ai:ceptable to remain in sen*ice.

Rekrencc W-ISI-EV-22-00-t F-A r:1.20A FWRR-0017 RIGID RESTRAINT EC 5-tll70627 e, aluated the "upport a, ai:L*eptablc 111 remain in sen il'L'. \\'-ISI-EY-22-00.1,,

1-'-A Fl.2013 F\\'RR-0005 Rl(i!D RESTRAINT EC LJ27.1,LJ c, a\uat..:d the uppllrt a, ,11.:i:eptabk to rL'lllain in en ii:e Reference \\'-ISI-EY-22-002

  • This report is being re\'isecl to include the items above to the RF-2.J Owners i\ctivit) Report.

Rel'crencc CR-\\'FJ-2023-1671.J.

TABLE 2:

ABSTH.-\Cl' OF REP.-\IIUREPL\CE;\IE:'\T ACTI\'ITIES REQl'IREn FOil Co:--TI:\l'ED SER\'ICE Code Item Dccriptiun Dc,cription or Work Date Repair/Replacement Class Completed Plan Number Items on this table are listed in NRC correspondence letter #

W3Fl-2022-0037.

3