W3F1-2022-0019, WAT-2022-02 Post Exam Analysis

From kanterella
Jump to navigation Jump to search
WAT-2022-02 Post Exam Analysis
ML22081A030
Person / Time
Site: Waterford Entergy icon.png
Issue date: 03/09/2022
From: Ledet R
Entergy Operations
To:
NRC Region 4
References
W3F1-2022-0019
Download: ML22081A030 (7)


Text

Questions asked After Grading (Post Exam Review Questions)

Question 21. (Name redacted)- He stated that the requirements given in the stem are not all of things that have to be verified. Why didnt we list them all in the stem? He was told that he was given a partial listing and choices only related to what was provided in the stem. He asked about Iodine not being mentioned and was told that Iodine was also not a choice for a distractor. The information related to iodine removal was not required to identify the correct answer from the choices given.

Question 37. (name redacted) - Questioned the logic for the pump start based on initiation of the EFW signal. A logic diagram, from the referenced lesson plan, was used to explain why the provided answer is correct. Student was satisfied with the response.