17265 River Road Killona, LA 70066 W3F1 -2004-0026 April 22, 2004 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001

Subject:

Annual Radiological Environmental Operating Report - 2003 Waterford Steam Electric Station, Unit 3 (Waterford 3)

Docket No. 50-382 License No. NPF-38

Dear Sir or Madam:

Attached is the Annual Radiological Environmental Operating Report for the period of January 1 through December 31, 2003. This report is submitted pursuant to the requirements of Waterford 3 Technical Specification Section 6.9.1.7.

If there are any questions please contact T.M. Manzella at (504) 739-6882.

There are no new commitments contained in this submittal.

Sincerely, G. Sen Licensing Manager GS/TMM/cbh Attachment(s)

- 1'_4 -,),s

W3F1-2004-0026 Page 2 cc: Mr. Bruce S. Mallett Regional Administrator U. S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 NRC Senior Resident Inspector Waterford Steam Electric Station Unit 3 P.O. Box 822 Killona, LA 70066-0751 U. S. Nuclear Regulatory Commission Attn: Mr. N. Kalyanam Mail Stop 0-07D1 Washington, DC 20555-0001 Wise, Carter, Child & Caraway ATTN: J. Smith P.O. Box 651 Jackson, MS 39205 Winston & Strawn ATTN: N.S. Reynolds 1400 L Street, NW Washington, DC 20005-3502

Attachment 1 W3FI -2004-0026 Annual Radiological Environmental Operating Report - 2003

-- E er A

'0 IS' -

  • 3* S m

I January 1, 2003 - December 31, 2003 I AT M I q

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Originator: a6?M. tt1?il do- 2e99'1 Ann V. Dubois, Chemistry Technician Date Reviewed By: Z//g/Oc- /a GlennM. ie ChemistryS rvisor Date Approved By: Lf-/9q-OL Glenn M. Pierce, Chemistry Superintendent Date

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station TABLE OF CONTENTS

SUMMARY

I

1.0 INTRODUCTION

5 1.1 Radiological Environmental Monitoring Program 5 1.2 Pathways Monitored 5 1.3 Land Use Census 5 2.0 INTERPRETATION AND TRENDS OF RESULTS 20 2.1 Air Particulate and Radioiodine Sample Results 20 2.2 Thermoluminescent DosimetrySample Results 20 2.3 Water Sample Results 21 2.4 Sediment Sample Results 22 2.5 Milk Sample Results 22 2.6 Fish Sample Results 22 2.7 Broad Leaf Vegetation Sample Results 22 2.8 Land Use Census Results 22 2.9 Interlaboratory Comparison Results 23 3.0 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

26 3.1 2003 Program Results Summary 26

- i-

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station LIST OF TABLES TABLE 1.1 RADIOLOGICAL ENVIRONMENTAL SAMPLING PROGRAM 6 TABLE 2.1 BIANNUAL LAND USE CENSUS RESULTS 24 TABLE 3.1 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

27

- ii -

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station LIST OF FIGURES FIGURE 1-1 REMP SAMPLES WITHIN 2 MILES OF WATERFORD 3 17 FIGURE 1-2 REMP SAMPLES WITHIN 10 MILES OF WATERFORD 3 18 FIGURE 1-3 REMP SAMPLES WITHIN 50 MILES OF WATERFORD 3 19 FIGURE 2-1 TLD RADIATION DOSE COMPARISON (BY YEAR) 25

- iii -

Annual Radiological 2003 Environmental Operatinq Report Waterford 3 Steam Electric Station LIST OF ATTACHMENTS ATTACHMENT I 2003 RADIOLOGICAL MONITORING REPORT

SUMMARY

OF MONITORING RESULTS 31 ATTACHMENT 2 STATISTICAL COMPARISONS 49 ATTACHMENT 3 2003 REVISED TRM TABLES 57

- iv -

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Summary The Annual Radiological Environmental Operating Report presents data obtained through analyses of environmental samples collected for Waterford 3's (W3) Radiological Environmental Monitoring Program (REMP) for the period January 1 through December 31, 2003. This report fulfills the requirements of W3 Technical Specification 6.9.1.7.

During 2003, gross beta radioactivity was detected in air and drinking water/surface water locations.

Results obtained at the indicator locations were similar to those obtained at the control location.

Therefore, levels continue to remain at background.

Tritium was detected in one sample at location SWK-1. Tritium was routinely released as measured in effluent sampling analysis via this pathway until March 2003. Tritium is no longer released via this pathway.

Radiological Environmental Monitorinq Program W3 established the REMP prior to the station becoming operational (1985) to provide data on background radiation and radioactivity normally present in the area. W3 has continued to monitor the environment by sampling air, water, sediment, milk, fish and broadleaf vegetation, as well as measuring radiation directly.

The REMP includes sampling indicator and control locations within a 40-mile radius of the plant. The REMP utilizes indicator locations near the site to show any increases or buildup of radioactivity that might occur due to station operation, and control locations farther away from the site to indicate the presence of only naturally occurring radioactivity. W3 compares indicator results with control, preoperational, and previous years operational results to assess any impact W3 might have on the surrounding environment.

In 2003, W3 collected environmental samples for radiological analysis. Based on the comparison results of indicator locations with control locations and previous studies, it was concluded that overall W3 operations had no significant impact on plant environs with the exception of surface water tritium where a direct correlation from plant operations exists below the reporting level. The review of 2003 data, in many cases, showed undetectable radiation levels in the environment and near background level in significant pathways associated with W3.

Harmful Effects or Irreversible Damage The REMP did not detect any harmful effects or evidence of irreversible damage in 2003. Therefore, no analysis or planned course of action to alleviate problems was necessary.

I

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Reporting Levels W3's review indicates that no samples equaled or exceeded reporting levels for radioactivity concentration in environmental samples, as outlined in Technical Requirements Manual (TRM)

Table 3.12-2 when averaged over any calendar quarter, due to W3 effluents. Therefore, 2003 results did not trigger any Radiological Monitoring Program Special Reports.

Radioactivity Not Attributable to W3 The W3 REMP detected radioactivity attributable to other sources twice. These include the 25th Chinese nuclear test explosion in 1980, and the radioactivity plume release due to reactor core degradation at the Chernobyl Nuclear Power Plant in 1986.

Comparison to State Program W3 compared REMP data to the monitoring program of the Environmental Radiological Laboratory -

Department of Environmental Quality Laboratory Services Division (ERL-DEQLSD). The ERL-DEQLSD and the W3 REMP entail similar radiological environmental monitoring program requirements. Both programs have obtained similar results over previous years.

Sample Deviations

  • Milk Samples Four milk samples were unavailable from indicator location MKQ-5 due to owner selling cows.

Four milk samples were unavailable from indicator location MKE-3 due to cows not producing enough milk. With the absence of milk samples at these locations, broadleaf vegetation sampling was performed as required by TRM Table 3.12-1.

  • Air Samples The air sample locations listed below failed to meet the requirement for sample continuity. As described in footnote (1) of TRM Table 3.12-1, deviations are permitted from the required sampling schedule due to malfunction of sampling equipment and other legitimate reasons.

Location Sample period Explanation of Deviation APE-30 12/30/02 - 01/14/03 GFI breaker trip APF-1 04/21/03 - 05105/03 Failed cal check and flow rate APE-30 04121/03 - 05/05/03 Loss of power APQ-1 08/11103 - 08/25/03 Sample pump tripped APE-30 12/01/03- 12/15/03 Failed cal check and flow rate 2

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station

  • Water Samples The drinking/surface water sample location listed below failed to meet the requirement for sample continuity. However, required LLDs were achieved. As described in footnote (1) of TRM Table 3.12-1, deviations are permitted from the required sampling schedule due to malfunction of sampling equipment and other legitimate reasons.

Location Sample period Explanation of Deviation SWK-1 02125/03 - 03/24/03 Low water in canal SWK-1 05/19/03 - 06/16103 Leak in hose SWK-1 10/06/03 - 11/03103 Replaced power converter

  • TLDs Station Q-1 was missing one TLD during the first quarter. The remaining TLD was left in place and read at the end of the quarter. Station B-4 TLDs were missing during the fourth quarter TLD inspection. Another set of TLDs were placed at this location and read at the end of the quarter.
  • Missed Samples TLDs located at station GA were missing at the time of the third quarter TLD exchange. TLDs located at station H-8 were missing at the time of the fourth quarter exchange.
  • Required Lower Limit of Detection (LLD) Values LLDs for Ba-1 40 for milk and water samples were not met for quarters 2, 3 and 4 of 2003.

Background fluctuation in samples rendered these LLDs unachieveable. However, it should be recognized that the LLD, a priori limit, representing the capability of a measurement system, did achieve the required LLDs. All other LLDs during this reporting period were within the acceptable limits required by the W3 TRM.

  • Unavailable Results W3 received analytical results in adequate time for inclusion in this report. In addition, W3's review identified no missing results.

Program Modifications The following changes were made to the TRM in accordance with NUREG 1301/Branch Technical Position during 2003:

  • The reporting level for tritium was changed from 20,000 pCi/I to 30,000 pCi/l if no drinking water pathway exists.
  • The reporting level for 1-131 in water was changed from 2 pCi/I to 20 pCi/I if no drinking water pathway exists.
  • The LLD for tritium was changed from 2,000 pCi/l to 3,000 pCiI if no drinking water pathway exists.
  • The LLD for 1-131 in water was changed from 1 pCi/l to 15 pCi/l if no drinking water pathway exists.
  • The LLD for Zr-95 was changed from 30 pCi/I to 15 pCi/I.
  • The LLD for Ba-140 was changed from 60 pCi/l in water and milk to 15 pCill in water and milk.

Copies of the affected TRM tables are included in this report in Attachment 3.

3

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Attachments contains results of air, TLD, water, sediment, milk, fish and broadleaf vegetation collected in 2003. TLDs were analyzed by Waterford-3 Dosimetry. All remaining samples were analyzed by the River Bend (RBS) Environmental Laboratory. Attachment 1 also contains River Bend's participation in the interlaboratory comparison program during 2003. contains statistical comparisons of:

  • TLD measurements from stations grouped by distance
  • TLD radiation dose to historical data by location
  • Gross beta activity measurements on air particulate filters
  • Gross beta activity measurements in surface/drinking water samples contains 2003 revised TRM tables.

4

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station 1.0 Introduction 1.1 Radiological Environmental Monitoring Program W3 established the REMP to ensure that plant operating controls properly function to minimize any associated radiation endangerment to human health or the environment. The REMP is designed for:

  • Analyzing important pathways for anticipated types and quantities of radionuclides released into the environment.
  • Considering the possibility of a buildup of long-lived radionuclides in the environment and identifying physical and biological accumulations that may contribute to human exposures.
  • Considering the potential radiation exposure to plant and animal life in the environment surrounding W3.
  • Correlating levels of radiation and radioactivity in the environment with radioactive releases from station operation.

1.2 Pathways Monitored The airborne, direct radiation, waterborne and ingestion pathways are monitored as required by W3 TRM Table 3.12-1. A description of the W3 REMP utilized to monitor the exposure pathways is described in Table 1.1 and shown in Figures 1-1, 1-2 and 1-3.

Section 2.0 of this report provides a discussion of 2003 sampling results with Section 3.0 providing a summary of results for the monitored exposure pathways.

1.3 Land Use Census W3 conducts a land use census biannually, as required by Section 3.12.2 of the TRM. The purpose of this census is to identify changes in uses of land within five miles of W3 that would require modifications to the REMP and the Offsite Dose Calculation Manual (ODCM). The most important criteria during this census are to determine the location in each sector of the nearest:

1) Residence
2) Animal milked for human consumption
3) Garden of greater than 50 m (500 ft2) producing broadleaf vegetation.

W3 conducts the land use census by

  • Field surveys in each meteorological sector out to five miles in order to confirm:

> Nearest permanent residence

> Nearest garden and approximate size

> Nearest beef cow

> Nearest food product

> Nearest milking animal.

  • Identifying locations on maps, measuring distances to W3 and recording results on data sheets.
  • Comparing current census results to previous results.

5

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Airbomne Radlolodine and Particulates Three samples from close to the three APQ-1 (NW, 0.81 Miles) - (West bank) Continuous sampler operation Radioiodine Canister 131 SITE BOUNDARY locations, in different Located in soybean/sugarcane field off with sample collection bi- analysis biweekly.

sectors, in or near sectors having the LA 18 approximately 0.6 miles east of LA weekly, or more frequently if highest calculated annual average 18/3141 intersection.

ground level D/Q. required by dust loading. Particulate Sampler - Gross APF-1 (ESE, 0.35 Miles) - (West bank) beta radioactivity analysis Located on north side of Secondary following filter change. Gamma Meteorological Tower. isotopic analysis of composite APC-1 (NE, 0.67 Miles) - (East bank) (by location) quarterly.

Located Inside the Little Gypsy Cooling Water Intake Structure fence enclosure.

Radlolodine and Particulates One sample from the vicinity of a APP-1 (WNW, 0.84 Miles) - (West bank) community having the highest Located In soybean/sugarcane field at calculated annual average ground level northwest comer of Short St. in Killona.

DIQ.

Radlolodine and Particulates One sample from a control location, as APE-30 (E, 25.2 Miles) - (West bank) for example 15 -30 km distant and in Located on the roof of the Entergy Office the least prevalent wind direction. building on Delaronde St. in Algiers.

(Control) 6

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Direct TLDs Radiation An inner ring of stations, one in each A-2 (N, 1.27 Miles) - (East bank) Located Quarterly Gamma dose quarterly.

meteorological sector in the general on a utility pole on LA 628 near the Zephrin area of the SITE BOUNDARY. L. Perriloux Fire House.

B-1 (NNE, 0.75 Miles) - (East bank) On fence enclosing the transmission tower 0.3 miles west (up-river) from Little Gypsy on LA 628.

C-1 (NE, 0.67 Miles) - (East bank) On fence enclosing the Little Gypsy Cooling Water Intake on LA 628 near APC-1.

D-2 (ENE, 1.24 Miles) - (East bank)

Located approximately 0.3 miles east of Little Gypsy Power Station on stop sign post located at the peak of the levee on the west entrance road through the Bonnet Carre Spillway.

7

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Direct TLDs Radiation An Inner ring of stations, one in each E-1 (E, 0.41 Miles) - (West bank) Located on Quarterly Gamma dose quarterly.

meteorological sector in the general utility pole along LA 18 approximately 0.3 area of the SITE BOUNDARY. miles east of Waterford 3 plant entrance.

F-2 (ESE, 1.15 Miles) - (West bank) Located on southeast comer of fence enclosure surrounding the Entergy sub station 0.2 miles south of LA 18 on LA 3142.

G-2 (SE, 1.26 Miles) - (West bank) Located on fence east of LA 3142 approximately 0.3 miles north of railroad overpass.

H-2 (SSE, 1.54 Miles) - (West bank) Located off LA 3142 on southwest edge of fence along shell road 0.4 miles north of LA 3127/3142 Intersection.

8

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Direct TLDs Radiation An Inner ring of stations, one in each J-2 (S, 1.38 Miles) - (West bank) Located on Quarterly Gamma dose quarterly.

meteorological sector in the general fence enclosure for valve station south of LA area of the SITE BOUNDARY. 3127 approximately 0.6 miles west of LA 3127/3142 Intersection.

K-1 (SSW, 1.06 Mlies) - (West bank) Located on stop sign at entrance to Entergy Education Center on LA 3127.

L-1 (SW, 1.06 Miles) - (West bank) Located on gated entrance off of LA 3127 approximately 1.6 miles west of LA 3127/3142 intersection.

M-1 (WSW, 0.76 Miles) - (West bank)

Located on south gate of Waterford 1 and 2 fuel oil storage tank enclosure.

N-1 (W, 0.98 Miles) - (West bank) Located on pole at comer of Railroad Avenue and School House Road.

9

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Direct TLDs Radiation An Inner ring of stations, one in each P-1 (WNW, 0.84 Miles) - (West bank) Quarterly Gamma dose quarterly.

meteorological sector in the general Located on fence enclosing air sample station area of the SITE BOUNDARY. APP-1.

Q-1 (NW, 0.81 Miles) - ((West bank) Located on fence enclosing air sample station APQ-1.

R-1 (NNW, 0.51 Miles) - (West bank) Located at Waterford 1 and 2 Cooling Water Intake Structure on east handrail approximately a quarter of the way down the catwalk.

TLDs An outer ring of stations, 1 in 10 of the A-5 (N, 4.59 Miles) - (East bank) Located on meteorological sectors in the 6- to 8- utility pole at intersection of Oswald Avenue km range from the site. and US 61.

10

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Direct TLDs Radiation An outer ring of stations, 1 in 10 of the B-4 (NNE, 3.75 Miles) - (East bank) Located Quarterly Gamma dose quarterly.

meteorological sectors in the 6- to 8- on utility pole guidewire next to transmission km range from the site. tower south of weigh station on US 61 at St.

John/St. Charles Parish line.

D-5 (ENE, 4.09 Miles) - (East bank) Located on gate on shell road approximately 0.1 miles north of US61/LA48 intersection.

F-4 (ESE, 3.53 Miles) - (West bank) Located on utility pole behind house at 646 Aquarius St. in Hahnville.

11

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and DIrectIon Collection Frequency Of Analyses Direct TLDs Radiation An outer ring of stations, 1 in 10 of the E-5 (E, 4.08 Miles) - (East bank) Located on Quarterly Gamma dose quarterly.

meteorological sectors in the 6- to 8- the Norco Substation fence enclosure at the km range from the site. end of Wesco Street off of LA 48.

G-4 (SE, 3.30 Miles) - (West bank) Located on railroad sign on LA 3160 approximately 0.1 miles north of railroad track.

H-8 (SSE, 8.13 Miles) - (West bank) Located on a road sign on south side of HWY 90 directly in front of Hahnville High School approximately 0.1 miles east of Tiger Drive.

P-6 (WNW, 5.58 Miles) - (West bank)

Located on a fence surrounding the communications tower at the LA 640/railroad track intersection.

Q-5 (NW, 5.01 Miles) - (West bank) Located on utility pole along LA 18 across from Mississippi River marker 137.

12

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Direct TLDs Radiation An outer ring of stations, 1 in 10 of the R-6 (NNW, 5.52 Miles) - (East bank) Located on Quarterly Gamma dose quarterly.

meteorological sectors in the 6- to 8- fence enclosure approximately 0.2 miles west of km range from the site. US 61 on LA 3223 near railroad crossing.

TLDs The balance of the stations to be in F-9 (ESE, 8.18 Miles) - (East bank) Located on special Interest areas such as entrance gate to Destrehan Substation just north population centers, nearby residences, of railroad tracks on Jonathan Street schools, and in I or 2 areas to serve approximately 1.5 miles east of Luling-Destrehan as control stations. Bridge, off of LA 48.

G-8 (SE, 7.74 Miles) - (West bank) Located on southern most comer of the back fence of Entergy Office in Luling.

E-15 (E, 11.7 Miles) - (East bank) Located on Kenner Substation fence enclosure on Alliance Ave approximately 0.1 miles from LA 48.

13

Annual Radiological 2003 Environmental Oneratino Report Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Direct TLDs Radiation The balance of the stations to be in J-15 (S, 11.7 Miles) - (West bank) Located on utility Quarterly Gamma dose quarterly.

special interest areas such as pole near the LA 631/Hwy 90 intersection in Des population centers, nearby residences, Allemands.

schools, and in 1 or 2 areas to serve as control stations. E-30 (E, 25.2 Miles) - (West bank) Located at entrance to the Entergy Office on Delaronde St. in Algiers. (Control)

Waterbome Surface Water One sample upstream SWP-7 (WNW, 7.37 Miles) - (West bank) Located at Composite sample over Gamma Isotopic analysis St. John Parish Waterworks off LA 18 in Edgard. one quarter period. quarterly. Composite for (Control) tritium analysis quarterly.

One sample downstream SWF-2 (ESE, 1.51 Miles) - (West bank) Located at Dow Chemical Plant drinking water canal.

SWE-5 (E, 4.59 Miles) - (East bank) Located at St.

Charles Parish Waterworks off LA 48 in New Sarpy.

SWK-1 (SSW, 0.49 Miles) - (West bank) Located at 40 Arpent Canal south of the plant. The canal is northwest of the shell access road/railroad track intersection.

14

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Pr gram Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Waterbome Drinkinn Water One sample upstream DWP-7 (WNW, 7.37 Miles) - (West bank) Located Composite sample over one 1-131 analysis on each at St. John Parish Waterworks off LA 18 in Edgard. momposite when theodose (Control) month penod when 1-131 composite when the dose analysis is performed, quarterly calculated for the consumption of One sample downstream DWF-2 (ESE, 1.51 Miles) - (West bank) Located at composite otherwise. the water is greater than one Dow Chemical Plant drinking water canal. mrem per year. Composite for DWE-5 (E,4.59 Miles) - (East bank) Located at St. gross beta and gamma isotopic Charles Parish Waterworks off of LA 48 in New analyses quarterly. Composite Sarpy. for tritium analysis quarterly.

Sediment from Shoreline One sample upstream SHWQ-6 (NW, 5.99 Miles) - (East bank) Located of Annually Gamma Isotopic analysis LA 628 approximately 0.1 miles east of Reserve fery landing. (Control) annually.

One sample downstream . SHWE-3 (E,2.99 Miles) - (West bank) Located at Foot Ferry landing off LA 18 in Taft.

SHWK-1 (SSW, 0.49 Miles) - (West bank) Located at 40 Arpent Canal south of plant. The canal is northwest of the shell access road/railroad track intersection.

Ingestion Mlk Samples from milking animals inthe MKE-3 (E,2.4 Miles) - (West bank) Located at the Quarterly Gamma isotopic and 1-131 three locations within 5 km distance Zeringue's house on LA 18 in Taft. analysis quarterly.

having the highest dose potential. If .

there are none, then, one sample MKQ-5 (NW, 4.99 Miles) - (West bank) Located at from milking animals in each of the the Webres house on LA 18 across from three areas between 5 to 8 km Mississippi River marker 137.

distant where doses are calculated to be greater than 1 mrem per year.

15

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 1.1 Radiological Environmental Sampling Program Exposure Requirement Sample Point Description, Sampling and Type and Frequency Pathway Distance and Direction Collection Frequency Of Analyses Ingestion Milk One sample from milking animals at a MKR-40 (NNW, 4070 Miles) - (East bank) Located Quarterly Gamma isotopic and 1-131 control location 15 - 30 km distant and at 24254 LA Highway 442, Holden. La. (Control) analysis quarterly.

in the least prevalent wind direction.

Fish and Invertebrates One sample of each commercially and FH-2 (Distance/Direction Not Applicable) - Sample in season, or Gamma isotopic analysis recreational Important species in Downstream of the plant intake structure. annually if they are not on edible portion.

vicinity of plant discharge area. seasonal FH-3 (Distance/Direction Not Applicable)-

(Westbank) Waterways downstream of plant discharge directed to 40 Arpent Canal.

One sample of same species In area FH-1 (Distance/Direction Not Applicable) -

not influenced by plant discharge. Upstream of the plant discharge structure. (Control)

Broadleaf Samples of one to three different kinds BLQ-1 (NW, 0.83 Miles) - (West bank) Located near Quarterly Gamma isotopic and 1-131 of broadleaf vegetation grown nearest air sample station APQ-1. analysis.

each of two different off-site locations of highest predicted annual average BLB-1 (NNE, 0.81 Miles) - (East bank) Located near groundlevel D/Q if milk sampling is not transmission tower west of Little Gypsy on LA 628.

performed.

One sample of each of the similar BLE-20 (E, 19.7 Miles) - (West bank) Located on broadleaf vegetation grown 15 - 30 km property of Nine Mile Point in Westwego, LA.

distant in the least prevalent wind (Control) direction If milk sampling Is not performed.

16

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station FIGURE 1-1 17

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station FIGURE 1-2 REMP Samples Within A/ .. ,..

2 to 10 Miles of Waterford-3 R 'I N Q

- S.

r~, '

'- S<t. G e .rt Samle Ml sK H.

o2/ Wr Dtndn r _ ,- . A / I $*sbew ASample Typtem r \ \* TLD

.* FsheUn dmt 202--

4 MlsH

__U

  • o icing Water W ~ W tK j

18

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station FIGURE 1-3 19

Annual Radiological 2003 Environmental Operating Report Waterford 3Steam Electric Station 2.0 Interpretation and Trends of Results 2.1 Air Particulate and Radlolodine Sample Results Samples of airborne particulate and radioiodine were collected at four indicator locations and one control location and analyzed for gross beta radionuclides, lodine-131 and gamma radionuclides (quarterly air particulate filter composites only). W3 did not detect any gamma radionuclides in the quarterly air particulate composites or lodine-131 in the radioiodine cartridges during the reporting period, as has been the case in previous years. Indicator gross beta air particulate results for 2003 were similar to those background levels obtained in previous years of the operational REMP and well below preoperational levels as seen below.

3 Results are reported as annual average pCi/m .

Monitoring Period Result Preoperational 0.080 1983- 2002 0.019 2003 0.020 Table 3.1, which includes gross beta concentrations for 2003, provides a comparison of the indicator and control means further emphasizes that the airborne pathway continues to remain at background levels. In addition, as shown in Attachment 2, the standard "t" test was used to compare average gross beta activity from each indicator station to the average gross beta activity at the control station. The results from this test show the average activity detected at all indicator stations is statistically the same as the average activity detected at the control station. Therefore, W3 concluded that plant operations had no significant impact on this pathway during 2003.

2.2 Thermoluminescent DosimetrySample Results The average exposure rates during 2003 are consistent with those from the preoperational program and the previous five years of operation as seen in Figure 2-1. In particular, the preoperational survey indicates that exposure rates ranged between 11 and 33 mrem/standard quarter with an average of 20 mrem/standard quarter. The range during the previous five years of operation was 9 to 15 mrem/standard quarter with an average exposure rate of 12 mrem/standard quarter.

A comparison of the indicator results to the control results, as seen in Table 3.1, shows that the average indicator is slightly higher than that of the control. As shown in Attachment 1, Table 2.1, several indicator locations are higher than the control by a few mrem with a maximum difference of five mrem at one location (G-2).

As shown in Attachment 2,Table 2.1, the standard "t" test was used to compare average exposure rates for TLD stations located in groups 0-2 miles and 2-5 miles from the plant to those > 5 miles. The results indicate that the average exposure rates 0-2 miles and 2-5 miles from the plant are statistically the same as those > 5 miles.

The differences between indicator locations and the control, and TLD stations grouped by distance from the plant are expected due to a variety of factors not related to W3 plant operations that can affect background radiation in the vicinity of each TLD station. Direct radiation measurements at each TLD station have remained statistically the same in 2003 as previous years of operation as evidenced on Attachment 2, Table 2.2. In addition, Radiological Gaseous Effluents for 2003 were only a small fraction of the limits as istypical in previous years of operation and are not expected to have any impact on environmental TLD measurements.

20

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station 2.3 Water Sample Results Analytical results for 2003 drinking/surface water samples were similar to those reported in previous years.

DrinkinulSurface Water Drinking water samples also serve as surface water samples for W3. Therefore, monthly and quarterly gamma spectroscopy and tritium analyses of drinking water also satisfy the surface water sampling requirement.

Composite drinking/surface water samples were collected from two indicator and one control location and analyzed for lodine-131, gamma radionuclides and tritium. Results indicate that all measurements were below the calculated LLDs.

Although gross beta was detected in the drinking/surface water samples, results for the indicator locations were below previous operational and preoperational years as seen below.

Results are reported as annual average pCiI.

Monitoring Period Result Preoperational 7.0 1983 -2002 5.2 2003 3.0 Table 3.1, which includes gross beta concentrations for 2003, provides a comparison of the indicator and control means shows that the waterborne pathway continues to remain at background levels. In addition, as shown in Attachment 2, the standard "tn test was used to compare average gross beta activity from each indicator station to the average gross beta activity from the control station. The results from this test show average activity detected at all indicator stations is statistically the same as the average activity detected at the control station. Therefore, W3 concluded that plant operations had no significant impact on this pathway during 2003.

Surface Water Surface water samples were collected from one indicator location and analyzed for gamma radionuclides and tritium. W3 did not detect any gamma radionuclides in surface water samples during the reporting period.

Tritium concentrations detected in 2003 are higher than those from the preoperational program as seen below. Results are reported as annual average pCi/l.

Monitoring Period Result Preoperational 121 1983-2002 1064 2003 21673 Tritium is expected due to liquid effluent releases from the Turbine Building Industrial Waste Sump (TBIWS) normally being directed to the 40 Arpent canal where samples are collected.

Water from this pathway is typically discharged at a rate of approximately 20,000 gallons per day total with tritium concentration ranging from 1.81 E-6 uCi/ml to l.56E-4 uCi/ml. The plant effluent is diluted by adjoining canals and rain, which can vary significantly depending on weather conditions, prior to reaching the sample location. As a result, samples collected after periods of heavy rain can indicate concentrations below detection levels, while those collected during dry periods have the potential to approach concentrations discharged directly from the plant via the TBIWS.

21

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Minor primary to secondary leakage has resulted in a rising trend in TBIWS tritium levels.

This was identified in the 4 quarter of 2002. Actions were taken to address the rise to prevent the approach of the reporting limit for SWK-1. Tritium is no longer released via this pathway as of March 2003. Modification was installed to divert this pathway to circ water.

2.4 Sediment Sample Results Sediment samples were collected from two indicator locations and one control location and analyzed for gamma radionuclides. Results indicate that all measurements were below the calculated LLDs. Therefore, W3 concluded that plant operations had no significant impact on this pathway during 2003.

2.5 Milk Sample Results Milk samples were collected from one indicator and one control location and analyzed for lodine-131 and gamma radionuclides. Results indicate that all measurements were below the calculated LLDs. Therefore, W3 concluded that plant operations had no significant impact on this pathway during 2003.

2.6 Fish Sample Results Fish samples were collected from two indicator and one control location and analyzed for gamma radionuclides. Results indicate that all measurements were below the calculated LLDs. Therefore, W3 concluded that plant operations had no significant impact on this pathway during 2003.

2.7 Broadleaf Vegetation Sample Results Broadleaf vegetation samples were collected from two indicator and one control location and analyzed for lodine-131 and gamma radionuclides. Results indicate that all measurements were below the calculated LLDs. Therefore, W3 concluded that plant operations had no significant impact on this pathway during 2003.

2.8 Land Use Census Results In compliance with the Waterford 3 ODCM and TRM, the land use census was conducted on September 24, September 30 and October 8, 2002. The nearest residence, garden, beef cow, food product and milk animal in each sector within a five mile radius of the plant was located by visual inspection and verbal inquiry.

While garden and food product locations remained unchanged for 2002, one location of goats (sector E) and one location of milk cows (sector Q) were removed. One new resident location (sector Q), one new milk cow location (sector E) and one new beef cow location (sector E) was identified in 2002. Based upon the locations identified in this survey, the locations identified in previous surveys and the locations currently being used to calculate dose commitments from liquid and gaseous effluents released from W3, no REMP sampling location changes are necessary. Results of the 2002 biannual census are shown in Table 2.1.

22

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station 2.9 Interlaboratory Comparison Results The River Bend Station Environmental Laboratory analyzed interlaboratory comparison samples for W3 to fulfill the requirements of Section 5.7.2 of the ODCM. Attachment I contains these results. For the sample result outside the acceptable control limit, W3 and RBS's review indicated no impact on previously reported data. Attachment 1 also provides additional discussion regarding the sample result outside the acceptable control limit.

23

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station TABLE 2.1 Biannual Land Use Census Results Sector Direction Distance from Plant in Miles Milk Beef J Food Residence Garden Cows Cows Goats Products A

A N 1.3 1.7

  • 4.6 4.6 4.1 B NNE 1.1 1.3 A A A 1.3 C NE 0.9 0.9 A A A A A A A D ENE 0.9 0.9 A E E 2.2 2.2 **2.3 2.3
  • 2.3 0.3 F ESE 3.1 2.2 A 2.3 A 0.3 G SE 4.0 4.1 A 2.4 A 0.3 H SSE A A A A A 0.3 A A A A A J S 0.5 A A A A A K SSW 0.5 L SW A A A A A 0.5 A A A M WSW 1.4 1.2 0.5 A

N W 1.0 1.1 A 1.0 0.6 P WNW 0.9 0.9 A 0.9 A 0.6 A A Q NW 0.7 1.0 0.9 0.6 A A R NNW 3.0 3.0 4.9 2.6 A Indicates that nothing was found in the Sector within a five mile radius of Waterford 3

  • Animals were located at this distance from Waterford 3, but the milk is not currently used for human consumption
    • Samples are being obtained from animals at this location (MKE-3) for REMP 24

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station FIGURE 2-1 TLD RADIATION DOSE COMPARISON (BY YEAR)

TLD Radiation Dose Comparison By Year 40 40 5- Indcator . 35 Ca A$t Upper "t Rangie -. s,.,;:.~2# ., t ', ,., nK 30 LowerRange 30 20 20 Co 0 r 0,S1.dYvv-r;~.............  :~eV.~. .......

qC~ ~,, ~ ~ ~_ a.-,l * , -...... z, ,grz S! ,,,*;ro

0. w,* #t, , . . r r ,bv.,¢am.¢4:s. \W. ','#/-lb 9ea.!iE-..!v7.E 10lb

..'rt." £ s;\ /@ '* .............. sio. r.

l^

-N s,;.

r4 Z§u; e ,A 4^x'...........;; lb£ Il,.^' 10

= ev?

3~~~~

n-.CO .4 2e/X ^ ,q1 'P, A, j_ ,jZa

.b

, Nq

, Nq ,

Nq

, Nq . ,q .q

*.q lc i  ; t,I8\.../',b'

, S.b 'b r$wjCb;

. ' ;.9 '. 4 ,; vX'..'@7;r-_

_- z: ,,  : -_ .Nq4;>*'-r t ,\ - :

  • 5 YEA YEAR 25

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station 3.0 Radiological Environmental Monitoring Program Summary 3.1 2003 Program Results Summary

- Table 3.1 summarizes the 2003 REMP results. W3 did not use values reported as less than the lower limit of detection (<LLD) when determining ranges and means for indicator and control locations.

26

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station TABLE 3.1 Radiological Environmental Monitoring Program Summarv Name of Facility: Waterford 3 SES Docket No: 50-382 Location of Facility: St. Charles, Louisiana Reporting Period: January - December 2003 Sample Type Type & Number LLD b Indicator Locations Location with Highest Annual Mean Control Number of (Units) Of Analyses a Mean (F ) c Locations Nonroutine

[Range] Mean (F)c Results e

_______ _[

_____ Range]

Mean (F) C Location d IRange I Airborne Particulates GB 130 0.01 0.019 ( 102/104) APQ-1 0.020 ( 26/26 ) 0.020 (23/26) 0 (pCi/m3) [ 0.004 - 0.030 1 (NW, 0.81 mi.) [0.007 - 0.030 ] [0.004 - 0.030 GS 20 Cs-1 34 0.05 <LLD N/A N/A <LLD 0 Cs-1 37 0.06 <LLD N/A N/A <LLD 0 Airborne Iodine 1-131 130 0.07 <LLD N/A N/A <LLD 0 (pCI/in3 )

Indicator TLDs Gamma 120 (f) 12(118/120) G-2 15.3 (4 / 4) N/A 0 (mrem/Std. Qtr) [9.0- 15.3 ] (SE, 1.26 mi.) [14.7- 15.9 1 Control TLDs Gamma 4 (f) N/A N/A N/A 10 (4/4 ) 0 (mrem/Std. Qtr) [9.4-10.5 27

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station TABLE 3.1 Radiological Environmental Monitorinq Program SummarV Name of Facility: Waterford 3 SES Docket No: 50-382 Location of Facility: St. Charles, Louisiana Reporting Period: January - December 2003 Sample Type Type & Number LLD b Indicator Location Location with Highest Annual Mean Control Number of (Units) of Analyses a Mean ( F ) c Locations Nonroutine Range Mean (F) c Results e

[ Range]

Mean(F)c Location d [ Range l Surface Water & Gross Beta 12 4 3.0 (5 / 8) DWF-2 3.6 (3 14) 2.5 (3/4) 0 Drinking Water [1.2 -6.0] (ESE, 1.51 mi.) [2.1 -6.1] [2.0 - 3.2]

(pCi/I) 1-131 52 1 <LLD N/A N/A <LLD 0 H-3 12 2000 <LLD N/A N/A <LD 0 GS 12 Mn-54 15 <LLD N/A N/A <LLD 0 Fe-59 30 <LLD N/A N/A <LLD 0 Co-58 15 <LLD N/A N/A <LLD 0 Co-60 15 <LLD N/A N/A <LLD 0 Zn-65 30 <LLD N/A N/A <LLD 0 Zr-95 15 <LLD N/A N/A <LLD 0 Nb-95 15 <LLD N/A N/A <LLD 0 Cs-1 34 15 <LLD N/A N/A <LLD 0 Cs-137 18 <LLD N/A N/A <LLD 0 Ba-140 15 <LLD N/A N/A <LLD 0 La-140 15 <LLD N/A N/A <LLD 0 28

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station TABLE 3.1 Radioloaical Environmental Monitoring Program Summarv Name of Facility: Waterford 3 SES Docket No: 50-382 Location of Facility: St. Charles, Louisiana Reporting Period: Januarv - December 2003 Sample Type Type & LLD b Indicator Locations Location with Highest Annual Mean Control Locations Number of (Units) Number Mean (F) c Mean (F) c Nonroutine of Analyses a [Range ] [Range] Results e Mean(F)c Location d [ Range ]

Surface Water H-3 4 3000 21673 (1/4) SWK-1 21673 (1/4) N/A 0 (pCI/I) [SSW, 0.49 mi.]

GS 13 Mn-54 15 <LLD N/A N/A N/A 0 Fe-59 30 <LLD N/A N/A N/A 0 Co-58 15 <LLD N/A N/A N/A 0 Co-60 15 <LLD N/A N/A N/A 0 Zn-65 30 <LLD N/A N/A N/A 0 Zr-95 15 <LLD N/A N/A N/A 0 Nb-95 15 <LLD N/A N/A N/A 0 Cs-134 15 <LLD N/A N/A N/A 0 Cs-1 37 18 <LLD N/A N/A N/A 0 Ba-1 40 15 <LLD N/A N/A N/A 0 La-1 40 15 <LLD N/A N/A N/A 0 Shoreline GS 3 Sediment Cs-1 34 150 <LLD N/A N/A N/A 0 (pCi/kg dry) Cs-1 37 180 <LLD N/A N/A N/A 0 29

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station TABLE 3.1 Radiological Environmental Monitorina Program Summary Name of Facility: Waterford 3 SES Docket No: 50-382 Location of Facility: St. Charles, Louisiana Reporting Period: January - December 2003 Sample Type Type & Number LLD b Indicator Location with Highest Annual Mean Control Number of (Units) of Analyses a Location Locations Nonroutine Mean (F) c Mean (F) C Results e

[Range] [Range]

Mean (F) c Location d [ Range ]

Milk 1-131 4 1 N/A N/A N/A <LLD 0 (pCi/I)

GS 4 Cs-134 15 N/A N/A N/A <LLD 0 Cs-1 37 18 N/A N/A N/A <LLD 0 Ba-1 40 15 N/A N/A N/A <LLD 0 La-140 15 N/A N/A N/A <LLD 0 Fish GS 14 (pCi/kg wet) Mn-54 130 <LLD N/A N/A <LLD 0 Fe-59 260 <LLD N/A N/A <LLD 0 Co-58 130 <LLD N/A N/A <LLD 0 Co-60 130 <LLD N/A N/A <LLD 0 Zn-65 260 <LLD N/A N/A <LLD 0 Cs-1 34 130 <LLD N/A N/A <LLD 0 Cs-137 150 <LLD N/A N/A <LLD 0 Broadleaf Vegetation 1-131 12 60 <LLD N/A N/A <LLD 0 (pCi/kg wet)

GS 12 Cs-1 34 60 <LLD N/A N/A <LLD 0 Cs-1 37 80 <LLD N/A N/A <LLD 0 a GB = Gross beta; 1-131 = lodine-131; H-3 = Tritium; GS = Gamma scan.

b LLD = required lower limit of detection based on Waterford 3 TRM.

c Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations Is Indicated In parenthesis (F).

d Locations are specified (1) by name and (2) degrees relative to reactor site.

e Non-routine results are those which exceed ten times the control station value. If no control station value Is available, the result Is considered non-routine If It exceeds ten times the preoperational value for the location.

f LLD Is not defined In Waterford 3 TRM.

30

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Attachment 1 2003 Radiological Monitoring Report Summary of Monitoring Results 31

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station TABLE OF CONTENTS TABLE 1.1 AIR PARTICULATE FILTER 33 TABLE 1.2 RADIOIODINE CARTRIDGE 34 TABLE 1.3 AIR PARTICULATE FILTER 35 TABLE 2.1 THERMOLUMINESCENT DOSIMETERS 36 TABLE 3.1 DRINKINGISURFACE WATER 37 TABLE 3.2 DRINKING/SURFACE WATER 38 TABLE 3.3 DRINKING/SURFACE WATER 39 TABLE 3.4 DRINKINGISURFACE WATER 40 TABLE 3.5 SURFACE WATER 41 TABLE 4.1 SEDIMENT 42 TABLE 5.1 MILK 43 TABLE 6.1 FISH 44 TABLE 7.1 BROADLEAF VEGETATION 45 TABLE 8.1 INTERLABORATORY COMPARISON 46 32

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 1.1 Sample Type: Air Particulate Filter Analysis: Gross Beta Units: pCi/M 3 Start Date End Date APF-1 APQ-1 APP-1 APC-1 APE-30 (Indicator) (Indicator) (Indicator) (Indicator) (Control)

Required LLD 0.01 0.01 0.01 0.01 0.01 12-30-02 01-14-03 0.0255 0.0243 0.0251 0.0250 0.0300 01-14-03 01-27-03 0.0206 0.0268 0.0283 0.0267 0.0297 01-27-03 02-10-03 0.0284 0.0278 0.0284 0.0257 0.0276 02-10-03 02-25-03 0.0194 0.0208 0.0205 0.0185 0.0224 02-25-03 03-10-03 0.0153 0.0164 0.0164 0.0170 0.0179 03-10-03 03-24-03 0.0168 0.0165 0.0170 0.0160 0.0178 03-24-03 04-07-03 0.0180 0.0193 0.0178 0.0170 0.0178 04-07-03 04-21-03 0.0223 0.0201 0.0209 0.0217 0.0220 04-21-03 05-05-03 0.0094 0.0168 0.0181 0.0161 0.0049 05-05-03 05-19-03 0.0156 0.0151 0.0153 0.0154 0.0158 05-19-03 06-02-03 0.0206 0.0201 0.0206 0.0177 0.0179 06-02-03 06-16-03 0.0106 0.0109 0.0117 0.0099 0.0108 06-16-03 07-01-03 0.0069 0.0071 0.0063 0.0074 0.0037 07-01-03 07-14-03 0.0089 0.0093 0.0092 0.0086 0.0094 07-14-03 07-28-03 0.0147 0.0174 0.0163 0.0159 0.0567 07-28-03 08-11-03 0.0150 0.0147 0.0142 0.0147 0.0160 08-11-03 08-25-03 0.0069 0.0204 0.0101 0.0092 0.0111 08-25-03 09-08-03 0.0140 0.0162 0.0154 0.0142 0.0155 09-08-03 09-22-03 0.0235 0.0264 0.0258 0.0243 0.0256 09-22-03 10-06-03 0.0241 0.0257 0.0248 0.0244 0.0271 10-06-03 10-20-03 0.0248 0.0257 0.0275 0.0247 0.0260 10-20-03 11-03-03 0.0295 0.0296 0.0303 0.0297 0.0304 11-03-03 11-17-03 0.0226 0.0221 0.0210 0.0007 0.0218 11-17-03 12-01-03 0.0155 0.0162 0.0172 0.0160 0.0170 12-01-03 12-15-03 0.0237 0.0243 0.0232 0.0234 0.0293 12-15-03 12-29-03 0.0186 0.0188 0.0202 0.0179 0.0195 33

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 1.2 Sample Type: Radiolodine Cartridge Analysis: Iodine-131 Units: pCi/M 3 Start Date End Date APF-1 APQ-1 APP-1 APC-1 APE-30 (Indicator) (Indicator) (Indicator) (Indicator) (Control)

Required LLD 0.07 0.07 0.07 0.07 0.07 12-30-02 01 03 < 0.0184 <0.0188 <0.0205 <0.0143 <0.0338 01-14-03 01-27-03 < 0.0159 <0.0159 <0.0173 <0.0130 <0.0145 01-27-03 02-10-03 < 0.0154 <0.0101 <0.0120 <0.0097 <0.0167 02-10-03 02-25-03 < 0.0118 <0.0129 <0.0154 <0.0131 <0.0096 02-25-03 03-10-03 < 0.0135 <0.0177 <0.0176 <0.0106 <0.0150 03-10-03 03-24-03 < 0.0140 <0.0135 <0.0133 <0.0089 <0.0123 03-24-03 04-07-03 < 0.0159 <0.0151 <0.0169 <0.0125 <0.0142 04-07-03 04-21-03 < 0.0149 <0.0147 <0.0143 <0.0096 <0.0127 04-21-03 05-05-03 < 0.0382 <0.0145 <0.0147 <0.0120 <0.0415 05-05-03 05-19-03 <0.0116 <0.0149 <0.0129 <0.0114 <0.0154 05-19-03 06-02-03 < 0.0116 <0.0146 <0.0146 <0.0112 <0.0157 06-02-03 06-16-03 < 0.0126 <0.0135 <0.0129 <0.0118 <0.0129 06-16-03 07-01-03 < 0.0162 <0.0172 <0.0218 <0.0183 <0.0168 07-01-03 07-14-03 < 0.0140 <0.0113 <0.0148 <0.0126 <0.0140 07-14-03 07-28-03 < 0.0132 <0.0145 <0.0145 <0.0139 <0.0086 07-28-03 08-11-03 < 0.0148 <0.0107 <0.0163 <0.0100 <0.0137 08-11-03 08-25-03 < 0.0164 <0.0272 <0.0175 <0.0097 <0.0155 08-25-03 09-08-03 < 0.0162 <0.0156 <0.0159 <0.0105 <0.0215 09-08-03 09-22-03 < 0.0175 <0.0154 <0.0169 <0.0153 <0.0173 09-22-03 10-06-03 < 0.0156 <0.0136 <0.0152 <0.0102 <0.0122 10-06-03 10-20-03 < 0.0181 <0.0138 <0.0168 <0.0140 <0.0133 10-20-03 11-03-03 < 0.0116 <0.0148 <0.0141 <0.0087 <0.0112 11-03-03 11-17-03 < 0.0156 <0.0162 <0.0140 <0.0161 <0.0190 11-17-03 12-01-03 < 0.0159 <0.0122 <0.0146 <0.0105 <0.0153 12-01-03 12-15-03 < 0.0147 <0.0135 <0.0169 <0.0124 <0.0340 12-15-03 12-29-03 < 0.0156 <0.0155 <0.0156 <0.0096 <0.0125 34

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 1.3 Sample Type: Air Particulate Filter Analysis: Gamma Isotopic Units: pCil/m3 Location Quarterly Cs-1 34 Cs-1 37 Composite Required LLD -_ 0.05 0.06 APF-1 (Indicator) 1st < 0.0017 < 0.0018 APQ-1 (Indicator) 1st < 0.0019 < 0.0016 APP-1 (Indicator) 1st < 0.0020 < 0.0017 APC-1 (Indicator) 1st < 0.0017 < 0.0012 APE-30 (Control) 1st < 0.0015 < 0.0023 APF-1 (Indicator) 2nd < 0.0028 < 0.0017 APQ-1 (Indicator) 2nd < 0.0018 < 0.0015 APP-1 (Indicator) 2nd < 0.0012 < 0.0014 APC-1 (Indicator) 2nd <0.0021 <0.0009 APE-30 (Control) 2nd < 0.0029 < 0.0023 APF-1 (Indicator) 3rd <0.0021 <0.0021 APO-1 (Indicator) 3rd < 0.0022 < 0.0011 APP-1 (Indicator) 3rd < 0.0024 < 0.0012 APC-1 (Indicator) 3rd < 0.0019 < 0.0011 APE-30 (Control) 3rd < 0.0014 < 0.0012 APF-1 (Indicator) 4th < 0.0024 < 0.0025 APQ-1 (Indicator) 4th < 0.0020 < 0.0018 APP-1 (Indicator) 4th <0.0043 <0.0043 APC-1 (Indicator) 4th < 0.0019 < 0.0016 APE-30 (Control) 4th < 0.0018 < 0.0020 35

Annual Radiological 2003 Environmental Operatinq Report Waterford 3 Steam Electric Station Table 2.1 Sample Type: Thermoluminescent Dosimeters Analysis: Gamma Dose Units: mrem/Std. Qtr.

Indicator Locations Station 1st Qtr '03 2nd Qtr '03 3rd Qtr '03 4th Qtr'03 Annual Mean '03 A-2 12 13 13 12 13 A-5 11 12 12 12 12 B-1 12 12 12 13 12 B4 12 13 13 14 13 C-1 9 9 10 10 10 D-2 12 12 12 13 12 D-5 11 10 12 12 11 E-1 11 14 11 11 12 E-5 11 10 11 11 11 E-1 5 10 9 11 10 10 F-2 11 12 12 12 12 F-4 13 13 14 15 14 F-9 12 12 12 12 12 G-2* 15 15 16 16 15 G-4** 10 10 11 11 G-8 10 10 10 10 10 H-2 12 12 13 13 12 H-8** 13 12 13 12 J-2 12 12 12 12 12 J-1 5 12 12 13 13 13 K-1 11 11 12 12 12 L-1 14 13 13 13 13 M-1 12 10 11 11 11 N-1 13 12 12 13 13 P-1 9 9 9 10 9 P-6 14 13 13 13 13 Q-1 12 12 12 11 12 Q-5 11 11 11 11 11 R-1 7 8 10 10 9 R-6 10 10 10 10 10 Control Location Station 1st Qtr '03 2nd Qtr '03 3rd Qtr '03 4th Qtr '03 Annual Mean '03 E-30 10 9 10 10 10

  • Location with highest annual mean.
    • TLDs at location G4 were missing for 3Q03. TLDs at location H-8 were missing for 4Q03.

36

Annual Radiological 2003 Environmental Operatinq Report Waterford 3 Steam Electric Station Table 3.1 Sample Type: Drinking/Surface Water Analysis: Gross Beta Units: pCi/A Quarterly DWFISWF-2 DWE/SWE-5 DWPISWP-7 Composite (Indicator) (Indicator) (Control)

Required LLD _ 4 4 4 1st 2.11 <1.68 2.00 2nd 2.74 1.19 2.36 3rd 6.09 3.02 3.15 4th <3.67 <3.72 <3.58 37

Annual Radiological 2003 Environmental Operating Report . Waterford 3 Steam Electric Station Table 3.2 Sample Type: DrlnkinglSurface Water Analysis: Iodine-131 Units: pCi/I Collection SWK-1 DWF/SWF-2 DWEISWE-5 DWP/SWP-7 Date (Indicator) (Indicator) (Indicator) (Control)

LLD 1 I a1 a1 12-30-02 < 6.39 < 0.88 < 0.88 < 0.89 01-27-03 < 5.26 < 0.85 < 0.84 < 0.90 02-25-03 < 5.06 < 0.86 < 0.82 < 0.85 03-24-03 <12.69 < 0.79 < 0.89 < 0.77 04-21-03 < 5.71 < 0.82 <0.81 < 0.88 05-19-03 < 5.48 < 0.89 < 0.74 < 0.90 06-16-03 < 5.75 < 0.77 < 0.86 < 0.78 07-14-03 < 4.59 <0.81 < 0.88 < 0.74 08-11-03 < 6.64 < 0.87 < 0.89 < 0.78 09-08-03 <10.40 < 0.88 < 0.89 < 0.69 10-06-03 < 4.63 < 0.81 < 0.90 < 0.88 11-03-03 < 4.99 < 0.78 <0.84 <0.81 12-01-03 < 5.95 < 0.81 < 0.90 < 0.90 38

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 3.3 Sample Type: Drinking/Surface Water Analysis: Gamma Isotopic Units: pCiAi Location Collection Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 Cs-134 Cs-137 Ba-140 La-140 Date Required LLD O 15 15 30 15 30 15 15 15 18 15 15 DWFISWF-2 (Indicator) 03-24-03 <3.69 <3.84 <7.96 <2.26 < 5.26 <5.23 < 7.28 < 3.25 <4.54 <13.11 <6.24 DWEISWE-5 (Indicator) 03-24-03 <3.82 <4.29 <8.63 <4.39 < 9.32 <4.55 < 8.77 < 6.45 <6.02 <23.68 <5.72 DWP/SWP-7 (Control) 03-24-03 <5.24 <3.75 <9.45 <4.23 <12.58 <4.99 < 7.86 < 5.77 <3.66 <25.53 <7.52 DWFISWF-2 (Indicator) 06-16-03 <4.09 <4.15 < 6.70 <4.83 < 9.31 <4.65 < 8.66 < 4.19 <6.41 <18.70* <3.41 DWE/SWE-5 (Indicator) 06-16-03 <3.50 <4.80 < 8.20 <5.19 < 7.80 <5.43 < 6.87 < 5.15 <4.46 <20.40* <7.39 DWPISWP-7 (Control) 06-16-03 <4.13 <5.29 <12.8 <2.44 < 8.07 <7.08 < 8.03 < 6.69 <6.07 <19.80* <9.35 DWFISWF-2 (Indicator) 09-08-03 <3.08 <5.36 <10.80 <4.18 < 7.23 <2.91 < 9.51 < 5.18 <5.76 <22.90* <4.10 DWEISWE-5 (Indicator) 09-08-03 <4.65 <4.57 < 8.13 <3.53 < 7.52 <4.61 < 7.46 < 4.67 <3.91 <13.00 <3.66 DWPISWP-7 (Control) 09-08-03 <6.26 <5.78 <7.35 <3.96 < 8.94 <6.22 < 6.83 < 4.47 <5.60 <12.80 <6.07 DWFISWF-2 (Indicator) 12-01-03 <5.12 <4.06 <10.50 <4.86 < 9.47 <6.00 < 8.19 < 5.20 <4.24 <27.10* <9.69 DWEISWE-5 (Indicator) 12-01-03 <3.90 <3.55 < 8.48 <3.96 < 6.88 <5.46 < 7.80 < 3.74 <4.44 <20.00* <5.87 DWP/SWP-7 (Control) 12-01-03 <5.73 <4.83 <11.20 <5.73 <12.80 <4.87 <10.40 < 5.57 <5.39 <26.30* <6.74

  • See page 3 for details 39

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 3.4 Sample Type: Drinking/Surface Water Analysis: Tritium Units: pCiA Quarter DWFISWF-2 DWEISWE-5 SWK-1 DWPISWP-7 (Indicator) (Indicator) (Indicator) (Control)

Required LLD -_ 2000 2000 3000 2000 1st < 575.92 < 574.93 *21673.00 < 571.19 2nd < 583.77 < 569.29 < 578.87 < 580.39 3rd < 585.52 < 576.46 < 584.37 < 576.67 4 th < 588.91 < 576.77 < 576.69 < 578.21

  • See page 21 for details.

40

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 3.5 Sample Type: Surface Water Analysis: Gamma Isotopic Units: pCiA Location Collection Mn-54 Co-58 Fe-59 Co-60 Zn-65 Nb-95 Zr-95 Cs-134 Cs-137 Ba-140 La-140 Date Required LLD *O 15 15 30 15 30 15 15 15 18 15 15 SWK-1 01-27-03 < 4.92 < 4.94 < 9.97 <3.80 < 9.61 < 5.30 < 6.23 < 4.40 < 5.01 < 15.30 < 4.48 (Indicator) 01-27-03* < 5.25 < 4.35 <10.70 <6.95 < 13.80 < 4.57 < 10.30 < 4.16 < 6.76 <30.40 < 8.86 02-25-03 < 3.13 < 3.98 < 9.10 <3.66 < 3.66 < 4.77 < 7.30 < 4.24 < 4.54 <13.90 < 5.97 03-24-03 <12.60 <11.66 <23.92 <5.12 <27.88 <11.07 <15.77 <14.13 <13.85 <49.84 <11.77 04-21-03 < 6.50 < 3.45 < 7.33 <4.23 < 10.80 < 6.06 < 9.49 < 5.78 < 4.71 < 19.40* < 7.94 05-19-03 < 5.41 < 3.75 < 9.80 <5.58 < 8.06 < 4.72 < 7.14 < 6.03 < 5.79 <20.10* < 5.06 06-16-03 < 4.39 < 3.99 <10.33 <4.39 <12.40 < 2.14 < 8.75 < 4.22 < 5.69 <14.78 < 6.12 07-14-03 < 5.59 < 5.04 < 8.74 <7.30 < 8.56 < 5.66 < 3.17 < 4.39 < 6.12 <16.10* < 5.96 08-11-03 < 5.31 < 6.37 <11.20 <4.39 <10.40 < 6.57 <10.30 < 6.57 < 6.41 <21.70* < 5.90 09-08-03 < 7.92 <10.50 <13.40 <2.71 <15.20 < 8.44 < 3.61 < 8.15 < 7.63 <33.80* <11.90 10-06-03 < 4.00 < 5.06 < 8.92 <4.22 < 10.60 < 2.95 < 6.82 < 4.89 < 4.64 <13.40 < 5.64 11-03-03 < 2.98 < 3.48 < 8.98 <3.99 < 8.17 < 4.31 < 5.23 < 3.50 < 3.02 <12.90 < 4.17 12-01-03 < 5.09 < 4.11 < 8.29 <5.96 <13.90 < 5.26 < 7.42 < 5.30 < 6.14 <12.80 < 4.44

  • See page 3 for details Duplicate sample 41

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 4.1 Sample Type: Sediment Analysis: Gamma Isotopic Units: pCi/kg (dry)

Location Collection Mn-54 Co-58 Co-60 Cs-1 34 Cs-1 37 Date Required LLD n/a n/a n/a 150 180 SHWK-1 (Indicator) 04-28-03 < 25.3 < 20.4 < 24.7 < 25.5 < 34.1 SHWE-3 (Indicator) 04-28-03 < 28.5 < 27.9 < 30.5 < 23.8 < 25.8 SHWQ-6 (Control) 04-28-03 <27.8 <25.9 <32.8 <26.4 <35.2 42

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 5.1 Sample Type: Milk Analysis: lodine-131 and Gamma Isotopic Units: pCi/l Location Collection 1-131 Cs-134 Cs-137 Ba-140 La-140 Date Required LLD I 15 18 15 15

-MKE-3 (Indicator) 03-18-03 n/a n/a n/a n/a n/a

'MKQ-5(Indicator) 03-18-03 n/a n/a n/a n/a n/a MKR-40 (Control) 03-17-03 <0.89 <6.23 < 11.8 <29.3 < 6.85 MKE-3 (Indicator) 06-17-03 n/a n/a n/a n/a n/a

  • -MKQ-5 (Indicator) 06-17-03 n/a n/a n/a n/a n/a MKR-40 (Control) 06-16-03 <0.76 <6.64 < 9.83 <28.0 < 5.83
  • MKE-3 (Indicator) 09-16-03 n/a n/a n/a n/a n/a
      • MKQ-5 (Indicator) 09-16-03 n/a n/a n/a n/a n/a MKR-40 (Control) 09-15-03 <0.67 <6.65 < 9.09 <24.5^ < 7.34
    • MKE-3 (Indicator) 12-16-03 n/a n/a n/a n/a n/a
  • -MKQ-5 (Indicator) 12-16-03 n/a n/a n/a n/a n/a MKR-40 (Control) 12-15-03 <0.83 <6.69 < 8.80 <22.0- < 6.63
  • See page 3 for details
  • ^ Sample not available. Cow not producing enough milk.
    • Removing from the program; owner sold cows 43

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 6.1 Sample Type: Fish Analysis: Gamma Isotopic Units: pCi/kg (dry)

Location Collection Species Mn-54 Fe-59 Co-58 Co-60 Zn-65 Cs-134 Cs-137 Date Required LLD 130 260 130 130 260 130 150 FH-1 (Control) 10-14-03 Buffalo < 19.58 < 17.15 <89.64 < 18.54 < 59.68 <13.47 < 14.88 FH-1 (Control) 10-14-03 Carp < 14.67 < 18.35 < 71.38 < 18.91 < 36.61 < 12.82 < 10.55 FH-1 (Control) 10-22-03 Catfish < 28.99 < 37.80 < 129.79 < 45.03 < 96.64 < 30.37 < 28.81 FH-1 (Control) 10-14-03 Shad <11.40 <17.36 <58.27 <15.88 <29.95 <11.12 <10.82 FH-1 (Control) 10-14-03 Mullet <15.14 <17.02 < 8.41 <15.88 <46.93 <12.38 <12.39 FH-2 (Indicator) 11-06-03 Buffalo <12.32 <15.46 <31.91 < 8.21 <33.99 <11.93 <10.72 FH-2 (Indicator) 11-06-03 Carp < 6.56 < 8.40 <27.54 <10.14 <20.56 < 8.12 < 5.44 FH-2 (Indicator) 11-06-03 Shad < 18.92 < 26.20 < 30.78 < 14.60 < 38.03 < 17.10 < 14.00 FH-2 (Indicator) 11-06-03 Mullet < 14.52 < 21.26 < 50.99 < 19.05 < 41.27 < 13.66 < 11.90 FH-3 (Indicator) 10-30-03 Buffalo < 14.12 < 17.54 < 60.35 < 18.78 < 34.69 < 16.12 < 11.02 FH-3 (Indicator) 10-30-03 Carp <11.82 <15.37 <41.03 <17.31 <43.44 <10.45 <11.69 FH-3 (indicator) 10-30-03 Catfish < 9.84 <10.84 <42.74 <14.90 <34.15 <14.05 <11.22 FH-3 (Indicator) 10-30-03 Mullet < 14.36 < 18.56 < 59.03 < 19.95 < 33.32 < 11.16 < 15.99 FH-3 (Indicator) 10-30-03 Shad < 9.41 < 16.05 <44.97 <13.08 < 38.42 < 9.60 <10.75 44

Annual Radiological 2003 Environmental Operatinq Report Waterford 3 Steam Electric Station Table 7.1 Sample Type: Broad Leaf Vegetation Analysis: Iodine-131 and Gamma Isotopic Units: pCi/kg (wet)

Location Collection 1-131 Cs-134 Cs-137 Date Required LLD 60 60 80 BLQ-1 (Indicator) 03-03-03 < 43.1 < 51.6 < 47.5 BLQ-1 (Indicator) 06-02-03 < 49.8 < 40.0 < 56.3 BLQ-1 (Indicator) 09-09-03 < 58.3 < 37.7 < 38.6 BLO-1 (Indicator) 12-02-03 < 60.0 < 30.9 < 38.2 BLB-1 (Indicator) 03-03-03 < 58.3 < 41.6 < 46.6 BLB-1 (Indicator) 06-02-03 < 56.6 < 39.3 < 40.8 BLB-1 (Indicator) 09-09-03 < 55.7 < 43.7 < 38.4 BLB-1 (Indicator) 12-02-03 < 57.7 < 31.0 < 31.7 BLE-20 (Control) 03-03-03 < 43.6 < 29.3 < 38.2 BLE-20 (Control) 06-02-03 < 52.5 < 44.1 < 37.3 BLE-20 (Control) 09-09-03 < 57.0 < 40.8 < 41.4 BLE-20 (Control) 12-02-03 < 54.6 < 31.3 < 28.7 45

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 8.1 Sample Type: Interlaboratory Comparison Analysis: Gross Beta, Iodine-1 31, Tritium and Gamma Isotopic Sample Type Study Date Analysis RBS RBS RBS (units> 'Known Yalue Value N-DEVb N-RANGEr Charcoal E3757-125 6/12/03 1-131 62.0 +/- 10.7 62.3 0.09 0.095 Cartridge (fCI/cartridge)

Water E3756-125 6/12/03 BETA 268 +/- 69.6 224 -1.90 0.029 (pCl/liter) E3755-125 6112/03 CR-51 213 +/- 36.9 210 -0.24 0.638 MN-54 166 +/- 28.8 177 1.17 0.107 CO-58 83 +/-14.4 86 0.63 0.142 FE-59 88 +/-15.2 96.3 1.64 0.201 CO-60 118 +/- 20.4 127 1.27 0.250 ZN-65 162 +/- 28.1 178 1.75 0.547 1-131 81 +/-14 95.3 3.06d 0.438 CS-134 92 +/- 15.9 90.7 -0.25 0.257 CS-137 206+/- 35.7 218 1.01 0.057 CE-141 253+/- 43.8 260 0.50 0.117 E4034125 12111/03 H-3 2290 +/-397 2154 -1.03 0.500 Air Filter E4032-125 12/11/03 BETA 28 +/- 4.85 30.3 1.40 0.401 (pCi/filter) E4035-125 12/11/03 CR-51 272 +/- 47.1 260 -0.79 1.060 MN-54 168+/- 29.1 173 0.52 0.180 CO-58 107+/-18.5 109 0.27 0.220 FE-59 99 +/-17.2 107 1.34 0.180 CO-60 150 +/- 26 149 -0.08 0.320 ZN-65 191 +/- 33.1 200 0.82 0.220 CS-134 132 +/- 22.9 126 -0.74 0.080 CS-137 126 +/-21.8 124 -0.32 0.141 CE-141 196 +/- 34 196 0.03 0.271 Sediment E4033-125 12/11/03 CR-51 0.208 +/- 0.036 0.201 -0.611 0.341 (pCi/gram) MN-54 0.128 +/- 0.022 0.126 -0.226 0.231 CO-58 0.082 +/- 0.014 0.075 -1.549 0.360 FE-59 0.076 +/- 0.013 0.074 -0.380 0.855 CO-60 0.115 +/- 0.020 0.111 -0.602 0.719 ZN-65 0.146 +/- 0.025 0.149 0.395 0.769 CS-134 0.100 +/- 0.017 0.099 -0.173 0.473 CS-137 0.202 +/- 0.035 0.203 0.057 0.205 CE-141 0.149 +/- 0.026 0.146 -0.387 0.674 46

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Table 8.1 Sample Type: Interlaboratorv ComDarison Analysis: Gamma Isotopic Sample Tvpe Study Date Analysis RBS RBS RBS (units "Known" Value Value N-DEVb N-RANGEc Milk E3758-125 6/12/03 CR-51 239+/-41.4 230 -0.68 0.618 (pCi/liter) MN-54 186+/- 32.2 192 0.59 0.095 CO-58 93 +/-16.1 92.3 -0.12 0.191 FE-59 99 +/-17.2 107 1.34 0.537 CO-60 132 +/-22.9 141 1.22 0.134 ZN-65 181 +/- 31.4 189 0.80 0.261 1-131 103+/- 17.8 97.7 -0.90 0.057 CS-134 103 +/-17.8 101 -0.39 0.229 CS-137 230 +/- 39.8 234 0.33 0.077 CE-141 283 +/-49 280 -0.20 0.146 NOTES:

(a) The *known- values are listed with a range reflecting control (3 sigma) limits.

(b) The normalized deviation from the 'known' value Is computed from the deviation and the standard error of the mean; +/-2.000 is the warning limit and +/-3.000 Is the control limit. This Is a measure of accuracy of the analytical methods.

(c) The normalized range Is computed from the mean range, the control limit, and the standard error of the range;

+2.000 is the warning limit and +3.000 Is the control limit. This is a measure of precision of the analytical methods.

(d) The results reported were out of the control limits.

47

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Interlaboratorv Comparison Program Exceptions There was one result outside the control limits for accuracy in the 2003 cross check program participation studies. This result was in a gamma isotopic analysis of a water sample.

The result outside the control limits for accuracy was in the analysis of the nuclide 1-131 in sample study E3755-125 of 6/12/2003. RBS normalized-deviation for the analysis was +3.06 with control limits of +3.00. This high bias result is considered conservative and is considered as having no impact on past results of the program. 1-131 results were all within control limits in other cross check samples for the year 2003.

48

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station ATTACHMENT 2 Statistical Comparisons 49

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station TABLE OF CONTENTS TABLE 2.1 STATISTICAL COMPARISON OF 2003 TLD MEASUREMENTS FROM STATIONS GROUPED BY DISTANCE 53 TABLE 2.2 STATISTICAL COMPARISON OF 2003 TLD RADIATION DOSE TO HISTORICAL DATA BY LOCATION 54 TABLE 2.3 STATISTICAL COMPARISON OF 2003 GROSS BETA ACTIVITY MEASUREMENTS ON AIR PARTICULATE FILTERS 55 TABLE 2.4 STATISTICAL COMPARISON OF 2003 GROSS BETA ACTIVITY MEASUREMENTS IN DRINKING/SURFACE WATER SAMPLES 56 50

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station Statistical Analyses

  • Calculation of the Mean and Standard Deviation The mean and standard deviation for different groups of analyses are calculated using the following equations:

n X = E Xi

, Z n and

0.5 where

X = mean of sample population, S = standard deviation of sample population, n = number of samples in sample population, and Xi = value of the i'th sample.

51

Annual Radiological 2003 Environmental Operating Report Waterford 3 Steam Electric Station

  • Comparing Two Sample Population Means The means of two sample populations are compared for statistical difference using the standard "t" test. The use of the test requires the assumption that the data within the populations are normally distributed and that the true standard deviations of the mean are equal for both populations. The standard "t" test tests the hypothesis that the true means of both populations are equal. The "t" value can be calculated from the equation below (obtained from the CRC Standard Mathematical Tables, 26th Edition (1981)):

x-Y 05.

L(nx _ 2 S)YJ n,,+ny-2 ) n. n where:

t = calculated "t"value, X = mean of first data set, Y = mean of second data set, 77 = number of variables in first data set, S x = standard deviation of first data set, j7 y= number of variables in second data set, and S Y= standard deviation of second data set.

The calculated "t"value is used to test the hypothesis that the true mean of the first population (mx)is equal to the true mean of the second population (m y) assuming that the true standard deviation of both populations are equal (m x = m y). The calculated "t" value is compared to a tabular "t" value such that:

a if t > t p,, then reject the hypothesis when m x> m y,

b. if t < -t pn then reject the hypothesis when m <' m y,
c. if t > t P/2,n then reject the hypothesis when m x = m y, where t P/2,n and t pu are the tabular "t' values, with a preselected error (5%), confidence level (1- p) or (1-p,2), and degrees of freedom n = nx + ny - 2. Tabular values of the "t" were obtained from the CRC Standard Mathematical Tables, 26th Edition (1981).

52

Annual Radiological 2003 Cn-,r-nmontnl narnt-nn 0 -nn. IAIM.f4- §1 Cf-on M-44tn (t24fin CllVII~lilil~lildl VpL~ldtillQ RUV~lt V .1fullUI o t~llCtUII;Jdl TABLE 2.1 STATISTICAL COMPARISON OF 2003 TLD MEASUREMENTS FROM

- STATIONS GROUPED BY DISTANCE

- Stations Located 0-2 Stations Located 2-5 - Stations Located more than

____-_;;_'_-___ Miles from the Plant' -Miles from the Plant - 5 iles from the Plant Mean 11.77 11.79 11.39 (mRemlstd.qtr.)

Standard Deviation 1.64 1.21 1.24 (mRemlstd. qtr.)

Number in Sample 64 27 27 Calculated 't" Value 1.11 1.22 NA*

(comparison of stations 0-2 and 2-5 miles from the plant to stations >5 miles from the plant)

Tabular at" Value at 1.990(a) 2.008(a) NA*

95% Confidence(t0 .02 5,1)

(a) Results indicate the mean for stations located 0-2 miles and 2-5 miles from the plant are statistically identical to the mean for stations located more than 5 miles from the plant.

  • Not Applicable 53

Annual Radiological 2003

=nArnmtn$nl ln~rtffnn DPnnr4 Wnforfnri4 ' tfonm Morftrnn Qtstinn TABLE 2.2

- . STATISTICAL COMPARISON OF 2003 TLD RADIATION DOSE TO HISTORICAL DATA BY LOCATION'

, . ., Units: mrem,,Std. Qtr.

ffi a-Station 1990 -2002 Avg!. 1990-2002 Std. Dev."on .1990-2002 Range**. [ "2003 Avg** -.-. 2003 Std Devl' ,:: 2003 Ranges' A-2 14 1.4 11 18 13 0.6 12 13 A-5 13 1.5 10 17 12 . 0.5 11 12 B-1 13 1.6 11 19 12 0.5 12 13 B-4 13 1.2 12 17 13 0.8 12 14 C-1 9 1.4 7 13 10 0.6 9 10 D-2 12 2.2 8 19 12 0.5 12 13 D-5 12 1.7 9 18 11 1.0 10 12 E-1 11 1.3 10 16 12 1.5 11 14 E-5 12 1.7 9 17 11 0.5 10 11 E-15 11 1.9 8 16 10 0.8 9 11 E-30* 11 1.8 8 17 10 0.5 9 10 F-2 12 1.3 10 17 12 0.5 11 12 F-4 14 1.6 11 19 14 1.0 13 15 F-9 13 1.7 7 17 12 0.0 12 12 G-2 15 1.3 12 19 16 0.6 15 16 G4 11 1.5 9 16 10 0.6 10 11 G-9 12 2.1 9 19 10 0.0 10 10 H-2 13 1.2 11 18 13 0.6 12 13 H-6 12 1.3 10 17 13 0.6 12 13 J-2 13 1.3 11 17 12 0.0 12 12 J-15 13 1.6 11 17 13 0.6 12 13 K-1 11 1.4 9 16 12 0.6 11 12 L-1 13 1.4 10 16 13 0.5 13 14 M-1 12 1.6 10 18 11 0.8 10 12 N- 13 1.7 8 18 13 0.6 12 13 P-11 0 1.4 8 15 9 0.5 9 10 P-6 14 1.6 11 19 13 0.5 13 14 Q-1 12 1.3 10 16 12 0.5 11 12 Q-5 14 2.0 9 18 11 0.0 11 11 R-1 11 1.6 6 15 9 1.5 7 10 R-6 13 2.7 9 18 10 0.0 10 10

  • Control Location
    • Significant outliers were removed from data sets.

PERS data indicates an average of 20 mrem for all indicator locations with a range of 11to 33 and an average control of 18 mrem.

54

Annual Radiological 2003 9InAronmtnntn rlnnmtlnn IOnn~rfr

.__-....... .. ... _111 - 1-1 TABLE 2.3 STAISTCALCOMPARISON OF 2003 GROSS BETA ACT TY MEASUREMENTS ON AIR PARTICULATE FILTERS SA T PTIE N APF-1 P- A PP-IA C- PE 3 Mean 18.6 19.7 19.4 18.4 20.1 (10 3pCl/M 3)

Standard Deviation 6.17 5.68 6.18 5.98 7.22 (10 3pCl1M 3)

Number inSample 25 26 26 25 23 Calculated "t" Value 0.76 0.21 0.38 0.87 NA*

(comparison of the Indicator stations to the control station)

Tabular "t" Value at 2.015(a) 2.014(a) 2.014(a) 2.015(a) NA*

95% Confidence(tO.0251, )

(a) Results indicate the mean for the indicator stations isstatistically identical to the mean for the control station.

  • Not Applicable 55

Annual Radiological 2003 Environmental

.. ... ... ... ...Oneratin Renort

^, . ._.. .._ .; , . . Waterford 3 Steam Electric Station TABLE 2.4

-STATISTICAL 'COMPARISON'OF.2003 GROSS BETA'ACTIViTY ,,:"'.,, ,,,',,,, ,,-

~~~~~~:!: ; r,-,, .s 't-" , IN DRINKINGISURFACE WATER SAMPLES ',.::'."':E,':'

't9v..s'MEASUREMENTS U'!',-

~

  • DWF-2 '-;. DWPE, Mean 3.6 2.1 2.5 (pCilliter)

Standard Deviation 1.7 0.9 0.5 (pCilliter)

Number In Sample 3 2 3 Calculated "t" Value 1.09 0.55 NA*

(comparison of the indicator stations to the control station)

Tabular "t" Value at 2.776(a) 3.182(a) NA*

95% Confldence(to.02sn)

(a) Results indicate the mean for the indicator stations is statistically identical to the mean for the control station.

  • Not Applicable 56

Annual Radiological 2003 PnL'irn-mentl Onproatin PRnnrt Wntprf'nrte'A I Ztpinm 11P~pt-t4r Vtntinn ATTACHMENT 3 2003 REVISED TRM TABLES 57

Annual Radiological 2003 Environmental Oneratiny Renort Waterford 3 Steam Electric Station (DRN 02-216, Am. 51)

TABLE 3.12-2 (See note below)

I (DRN 02-216, Am. 51)

REPORTING LEVELS FOR RADIOACTIVITY CONCENTRATIONS IN ENVIRONMENTAL SAMPLES Reporting Levels AIRBORNE FOOD PARTICULATE FISH PRODUCTS WATER OR GASES (pCi/kg, MILK (pCi/kg, ANALYSIS (pCi/L) (pCi/M 3 ) wet) fpCi/I wet)

(DRN 03-255. Am. 73)

H-3 20,000*

I (DM'J 03-255. Am.73)

Mn-54 1,000 30,000 Fe-59 400 10,000 Co-58 1,000 30,000 Co-60 300 10,000 Zn-65 300 20,000 Zr-95 400 Nb-95 400 (DRN 03-255, Am 73) 1-131 0.9 3 100 I (DRN 03.255, Am 73)

Cs-134 30 10 1,000 60 1,000 Cs-137 50 20 2,000 70 2,000 Ba-140 200 300 La-140 200 300 (DRN 02-216, Am. 51)

NOTE: TRM Table 3.12-2 is part of the Offsite Dose Calculation Manual (ODCM), reference UNT-005-014. Revision of this TRM Table requires the approval of the General Manager Plant Operations (GMPO) in accordance with Technical Specification 6.14.

(DRN02-216,An 51)

(DRN 03-255, Am. 73)

  • For drinking water samples. This is 40CFR Part 141 value. If no drinking water pathway exists, a value of 30,000 pCi/l may be used. IqjJ
    • If no drinking water pathway exists, a value of 20 pCi/l may be used.

I (DRN03-255, Am 73) 3/4 12-10 AMENDMENT NO. 6, 73 58

Annual Radiological 2003 Envirnnmental Oneratincy Rennrt Waterford 3 Steam Electric Station (DRN 02-216, Am. 51)

TABLE 4.12-1 (See note below)

I (DRN 02-216. Am. 51)

DETECTION CAPABILITIES FOR ENVIRONMENTAL SAMPLE ANALYSIS (DRN 03-255, Am. 73)

LOWER LIMITS OF DETECTION (LLD)a"b"cc I (DRN 03-255, Am. 73)

AIRBORNE FOOD PARTICULAT FISH PRODUCTS SEDIMENT E

WATER OR GASES (pCi/kg, MILK (pCi/kg, (pCi/kg, ANALYSIS (pCi/I) (pCi/M 3 ) wvet) (pCi/l) wyet) dory Gross 4 0.01 Beta 0 (DRN 03-255, Am. 73)

H-3 2,000' I 0 I (DRN 03-255. Am. 73)

Mn-54 15 130 Fe-59 30 260 Co-58 15 130 Co-60 15 130 Zn-65 30 260 D (DUN 03-255. Am. 73)

Zr-95 15 I 0~

I (DRN 03-255, AnL 73)

Nb-95 15 1-131 0.07 I 60 Cs-134 15 0.05 130 15 60 150 Cs-137 18 0.06 150 18 80 180 D N03-255. Am 73)

Ba-140 I (DRN 03-255, Am. 73) 15 15 Q$

La-140 15 15 (DRN 02-216, Am. 51)

NOTE: TRM Table 4.12-1 is part of the Offsite Dose Calculation Manual (ODCM), reference UNT-005-014. Revision of this TRM Table requires the approval of the General Manager Plant Operations (GMPO) in accordance with Technical Specification 6.14.

l (DRN 02-216, A. 51) 3/4 12-11 AMENDMENT NO. 02,51-, 73 59

Annual Radiological 2003 Envirnnmpntal Onerntintv Rennrt v.....as v s

.as V- Waterford 3 Steam Electric Station (DRN 02-216, Am. 51)

TABLE 4.12-1 (See note below)

I (DRN 02-216, Am. 51)

TABLE NOTATIONS

a. This list does not mean that only these nuclides are to be considered Other peaks that are identifiable, together with those of the above nuclides, shall also be analyzed and reported in the Annual Radiological Environmental Operating Report pursuant to Technical Specification 6.9.1.7.
b. Required detection capabilities for thermoluminescent dosimeters used for environmental measurements shall be in accordance with the recommendations of Regulatory Guide 4.13.
c. Analyses shall be performed in such a manner that the stated LLDs will be achieved under routine conditions. Occasionally background fluctuations, unavoidable small sample sizes, the presence of interfering nuclides, or other uncontrollable circumstances may render these LLDs unachievable. In such cases, the contributing factors shall be identified and described in the Annual Radiological Environmental Operating Report pursuant to Technical Specification 6.9.1.7.

(DRN 03-255. Am. 73)

d. LLD for drinking water samples. If no drinking water pathway exists, a value of 15 pCi/I may I -

be used.

I (DRN03-255. Am 73)

e. The LLD is defined in the ODCM.

(DRN 03-255. Am 73)

f. If no drinking water pathway exists, a value of 3000 pCi/I may be used.

I (DRN 03-255. AN. 73) 1<_

(DRN 02-216. Am. 1)

NOTE: TRM Table 4.12-1 is part of the Offsite Dose Calculation Manual (ODCM), reference UNT-005-014. Revision of this TRM Table requires the approval of the General Manager Plant Operations (GMPO) in accordance with Technical Specification 6.14.

I (DRN02-216.Am 51) 3/4 12-11 AMENDMENT NO. 02, 1-, 73 60