Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20085B862 + (Followup Final Deficiency Rept,Item M-32,re Incomplete Hydraulic Analysis of Control Rod Drive Piping.Sargent & Lundy Engineers Evaluation Determined Piping to Be within ASME Code Allowables If Installed Per Design Drawings)
- IR 05000482/1985029 + (Followup Insp Rept 50-482/85-29 on 850624-28.Deviation Noted:Failure to Meet Commitment for Indoctrination of Visitors & Failure to Retain Monthly Communication Procedure Checklist)
- ML022390422 + (Followup Inspection for a Potential Old Design Issue Red Finding)
- TXX-6091, Followup Interim Deficiency Rept CP-86-54 Re Original Design & Installation of Control Room Ceiling.Initially Reported on 861003.Physical Const of New Ceiling Complete.Qc Verification Scheduled for Completion by 861128 + (Followup Interim Deficiency Rept CP-86-54 Re Original Design & Installation of Control Room Ceiling.Initially Reported on 861003.Physical Const of New Ceiling Complete.Qc Verification Scheduled for Completion by 861128)
- TXX-6207, Followup Interim Deficiency Rept CP-86-72 Re Scope of Plant Mods Resulting from Pipe Support Reverification Program. Initially Reported on 860609.List of Mods Issued to Date Encl.Next Rept Will Be Submitted on 870220 + (Followup Interim Deficiency Rept CP-86-72 Re Scope of Plant Mods Resulting from Pipe Support Reverification Program. Initially Reported on 860609.List of Mods Issued to Date Encl.Next Rept Will Be Submitted on 870220)
- ML20024B784 + (Followup Interim Rept Re Potential Deficiency in 5HK Switchgear Supplied by Brown Boveri.Circuit Breaker Inadvertently Closed & Tripped Following Spring Charging. Light Spring Added to Close Latch)
- ML20069F507 + (Followup Interrogatories & Requests to Produce Re Palmetto Contentions 6,7,8,16,27 & 44.Certificate of Svc Encl.Related Correspondence)
- ML19323D742 + (Followup Interrogatories Directed to Intervenor TMI Alert. Requests Technical Justification for Synergistic Effect Claim Re Gaseous Radioactive Releases.Certificate of Svc & Related Correspondence Encl)
- ML19323H757 + (Followup Interrogatories Directed to Licensee.Requests Documentation & Causes of Pipes Cracking in Borated Water Sys.Certificate of Svc Encl.Related Correspondence)
- ML19321B106 + (Followup Interrogatories Directed to Licensee.Requests Complete Narration of Events Leading to 800627 Accident Involving Leak of 10,000 Gallons of Contaminated Water. Certificate of Svc Encl)
- ML20071H064 + (Followup Interrogatories Re Des Contentions 11,17 & 19. Certificate of Svc Encl.Related Correspondence)
- ML20031D736 + (Followup Interrogatories to Applicant Re Matl Released by Applicant After 810610.Certificate of Svc Encl)
- ML20073T125 + (Followup Interrogatories to Palmetto Alliance Contentions 6, 7,8,16 & 27.Answer Must Be Filed by 830520.Certificate of Svc Encl.Related Correspondence)
- ML20005B523 + (Followup Interrogatories to Univ of CA Further Answers to Committee to Bridge the Gap First Set of Interrogatories. Responses Should Include All Info Available to Applicant. Certificate of Svc Encl)
- 05000318/LER-1983-007, Followup LER 83-007/01T-0:on 830203,de-energization of Reactor Protection Sys (RPS) Channels Caused PORV & Pressurizer Quench Tank Rupture Disk to Open.Caused by Blown Fuse in RPS Channel a Due to Crossed Leads in Inverter 21 + (Followup LER 83-007/01T-0:on 830203,de-energization of Reactor Protection Sys (RPS) Channels Caused PORV & Pressurizer Quench Tank Rupture Disk to Open.Caused by Blown Fuse in RPS Channel a Due to Crossed Leads in Inverter 21)
- 05000278/LER-1983-008, Followup LER 83-008/01X-1:on 830214,during Refueling Outage, Surveillance Testing Indicated Combined Leakage for Listed Valves Exceeded Limits or Failed to Meet Requirements.Caused by Seat Surface Degradation + (Followup LER 83-008/01X-1:on 830214,during Refueling Outage, Surveillance Testing Indicated Combined Leakage for Listed Valves Exceeded Limits or Failed to Meet Requirements.Caused by Seat Surface Degradation)
- 05000271/LER-1983-009, Followup LER 83-009/01T-0:on 830321,primary Containment Isolation Sys Isolation of Containment Ventilation Sys Occurred.Caused by Mods to Reactor Protection Sys Motor Generator.Fuel Handling Activities Suspended + (Followup LER 83-009/01T-0:on 830321,primary Containment Isolation Sys Isolation of Containment Ventilation Sys Occurred.Caused by Mods to Reactor Protection Sys Motor Generator.Fuel Handling Activities Suspended)
- 05000296/LER-1984-004-01, Followup LER 84-004-01:on 840228,RHR Outboard Loop II Isolation Valve CFV-74-67 Stem Found Broken Upon Disassembly.Caused by Overloading.Valve Stem Replaced W/Stronger & More Durable Matl + (Followup LER 84-004-01:on 840228,RHR Outboard Loop II Isolation Valve CFV-74-67 Stem Found Broken Upon Disassembly.Caused by Overloading.Valve Stem Replaced W/Stronger & More Durable Matl)
- 05000259/LER-1984-007-01, Followup LER 84-007-01:on 840127,operator Observed Decreasing Pressure on Control Atmospheric Dilution Tanks. Caused by Two Isolation Valves Being in Closed Position. Operating Instructions Revised + (Followup LER 84-007-01:on 840127,operator Observed Decreasing Pressure on Control Atmospheric Dilution Tanks. Caused by Two Isolation Valves Being in Closed Position. Operating Instructions Revised)
- ML20084U038 + (Followup LER BFRO-50-296/7618:on 761117,torus Oxygen Sensor Failed to Respond Properly to Calibr Gas During Surveillance Testing.Caused by Misalignment of Sensor & Calibr Piston Assembly.Corrective Actions Not Stated)
- ML19220A816 + (Followup Ltr to 760803 Verbal Notification of RO Re Response Time.Required Response Time Will Be Revised to Be Consistent W/Time Requirements for Emergency Cooling Booster Pumps)
- ML20036A911 + (Followup NPDES Noncompliance Notification:On 930504,pH of Waste Effluent Sample Exceeded Richland Pretreatment Ph Limit & High Ph in Solution Transferred to Lagoon 5A & to Sewer.Weekly Composite Samples of Waste Will Be Taken)
- RBG-31359, Followup NPDES Noncompliance Notification:On 890724, Total Suspended Solids at Outfall 002 in Violation.Util Determined Cause to Be Leak Which Introduced Gallons of Sulfuric Acid Into Sys Sump.Analysis Underway + (Followup NPDES Noncompliance Notification:On 890724, Total Suspended Solids at Outfall 002 in Violation.Util Determined Cause to Be Leak Which Introduced Gallons of Sulfuric Acid Into Sys Sump.Analysis Underway)
- RBG-38-253, Followup NPDES Noncompliance Notification:On 930311, Discovered That Approx 500 Gallons of 12% Solution of Sodium Hypochlorite Drained from Temporary Storage Tank to Containment Basin.Test Connection Valve Removed + (Followup NPDES Noncompliance Notification:On 930311, Discovered That Approx 500 Gallons of 12% Solution of Sodium Hypochlorite Drained from Temporary Storage Tank to Containment Basin.Test Connection Valve Removed)
- ML20046A248 + (Followup NPDES Noncompliance Notification:On 930715, Concentration of Clam-Trol Exceeded Permitted Level of 0.4 Mgv/L.Addl Measures Will Be Taken to Ensure That Appropriate Flow Rate for Detox Sys Exists)
- L-PI-12-083, Followup Notification Regarding a Deleted Commitment + (Followup Notification Regarding a Deleted Commitment)
- ML20125B148 + (Followup Part 21 & Deficiency Rept Re Failure of General Motors Corp Camshaft Bearing Support Bracket on Diesel Generator 2G003.Components Replaced & Retorqued & Front Bolt Holes on Support Bracket Enlarged)
- ML20198E281 + (Followup Part 21 & Deficiency Rept Re Signal Failure Potential in Safety Injection Recirculation Path.Initially Reported on 850724.Control Logic for Valves Will Be Changed)
- ML19325E086 + (Followup Part 21 Rept Re Class 1E Battery Chargers W/ Transformers Running at Temps Exceeding Those Used in Qualification Rept When Operating at or Near Full Load Rating of Equipment.Listed Corrective Actions Underway)
- ML20234F526 + (Followup Part 21 Rept Re Defective MIS-5 Actuating Fuses. Initially Reported on 870620.All Defective Fuses Will Be Replaced W/Fuses from Subsequent Lots Before Mode 4)
- ML20086U425 + (Followup Part 21 Rept Re Defective Mechanical Snubber Capstan Springs Supplied by Pacific Scientific.Affected Utils Listed.Purchasers Have Been Notified & Advised to Work Directly W/Pacific Scientific in Disposition)
- ML20128H456 + (Followup Part 21 Rept Re Disintegration of Balston 21554-1 Automatic Drain Float & Air Piping Filter Assemblies Mfg Prior to Nov 1989.Caused by Contaminants in Air Start Sys. Customers Should Order Air Filters Mfg After Nov 1989)
- ML20076B447 + (Followup Part 21 Rept Re Emergency Diesel Generator 2B-B in Parsons-Peebles Electric Products Synchronous Generator S/N 14701228,supplied by Ge.Plants Supplied W/Generators Identified.Notification Ltr to GE Encl)
- ML20128G946 + (Followup Part 21 Rept Re Failure of Display Circuit on Control Unit of microSelectron-HDR During Ongoing Treatment. Initially Reported on 930107.Caused by Intermittent Failure of Computer Clock Oscillator.Cpu Board Replaced)
- ML20086C861 + (Followup Part 21 Rept Re Failure to Update Room Pressurization Calculations to Reflect Final Design Vent Paths.Reactor Bldg,Room R206C Cannot Withstand Calculated Pressurization Following Postulated High Energy Line Break)
- ML17326B550 + (Followup Part 21 Rept Re Failures of Closing Mechanisms in Two Bbc Brown Boveri,Inc,Type 5HJK250 Circuit Breakers Installed in Safety Sys at Plant.Initially Reported on 890301.Maint Procedure Will Be Revised)
- ML20080D976 + (Followup Part 21 Rept Re Insp of Monel Shafts.Tests Will Be Conducted by Vendor on 830825 Using Encl Procedure 01-009-987)
- ML20081K520 + (Followup Part 21 Rept Re Leaking Tantalum Capacitors in Class IE,SA-1 Relays (Ref IE Info Notice 83-63).Customers Given Option of Returning Relays or Performing Field Mod)
- ML20087J666 + (Followup Part 21 Rept Re Nuclear Valve/Actuator Stroking Time Possibly Lengthened Beyond 15 When Using hydrocarbon-based Lubricants.Ltrs to Affected Utils Encl)
- ML20116K089 + (Followup Part 21 Rept Re Overcompression of Power Lead Gland Assembly Sealant During Factory Assembly.Procedures Revised to Specify That Only One Coat of Threaded Lubricant Will Be Applied.Proprietary Rept Encl.Rept Withheld)
- ML20052C075 + (Followup Part 21 Rept Re Potential Defect in Starting Air Check Valve of Dsrv Standby Diesel Generator,Initially Reported 811105.Modified Valve at sub-supplier for Seismic Evaluation.Recommendation for Corrective Action by 820715)
- ET-NRC-91-3627, Followup Part 21 Rept Re Potential for Certain Westinghouse Products,Utilizing Dc Coil Assemblies,To Malfunction.Caused by Epoxy Compound Becoming semi-fluid During Svc.Initially Reported on 910624.Epoxy Check Will Be Incorporated + (Followup Part 21 Rept Re Potential for Certain Westinghouse Products,Utilizing Dc Coil Assemblies,To Malfunction.Caused by Epoxy Compound Becoming semi-fluid During Svc.Initially Reported on 910624.Epoxy Check Will Be Incorporated)
- ML17328A228 + (Followup Part 21 Rept Re Westinghouse molded-case Circuit Breakers Observed to Trip Before Allowable Time Band,Per Generic Ltr 88-10.Initially Reported on 891207.Breakers Purchased Prior to 1989 Purchase Order Not Subj to Problems)
- ML20035C627 + (Followup Part 21 Rept,Consisting of Error Notices Received from Former Software Suppliers Re NUPIPE-II Code Failing to Produce Expected Results of Multiple Response Spectra Load Cases.Listed Former Customers Not Notified)
- BSEP-84-0494, Followup RO 2-SR-84-2:in Sept 1982,Co-60 Detected in Bottom Sediments Collected in Stilling Basin.Increase in Radioactivity Probably Caused by Increased Releases of Co-60 Due to General Decontamination Effort + (Followup RO 2-SR-84-2:in Sept 1982,Co-60 Detected in Bottom Sediments Collected in Stilling Basin.Increase in Radioactivity Probably Caused by Increased Releases of Co-60 Due to General Decontamination Effort)
- ML20082L149 + (Followup RO 83-01:on 831103,fire Suppression Water Sys Declared Inoperable After Pump 1-1 Failed Testing.Mod Underway to Install New Pressure Relief Valves on Both Fire Pumps)
- ML20029A754 + (Followup RO Per 910215 Telcon:On 910215,water Level in Reactor Tank Lower than Normal.Caused by Water Running Out from Under Concrete Block Shield Surrounding Demineralizer Tank.Barrier Dam Constructed Across HX Room)
- ML20082E997 + (Followup RO Re Fire Protection Cable Separation.Fire Watches Placed Where Cable Separation Criteria Not Met & Will Remain Until Corrective Actions Implemented.Fire Blankets Installed to Correct Three Nonconformaces)
- LIC-90-0569, Followup RO Re Inoperability of Fire Door 1013-7.Since Replacement Work for Door Involves Removal of Part of Pyrocrete Wall That Surrounds Door Opening,Door Operability Delayed Until 900801.Compensatory Measures in Place + (Followup RO Re Inoperability of Fire Door 1013-7.Since Replacement Work for Door Involves Removal of Part of Pyrocrete Wall That Surrounds Door Opening,Door Operability Delayed Until 900801.Compensatory Measures in Place)
- ML20137N888 + (Followup RO Re Inoperable Fire Doors Found During Routine Surveillance in Dec 1985.Eight Latching & Seven Closure Mechanism Failures Identified.Latches & Closure Mechanisms Will Be Upgraded)
- ML17325A238 + (Followup RO Re Portion of North Outside Fire Protection Ring Header That Had Been Isolated Due to Leaking Fire Hydrant, Per 870803 Rept.Leak Due to Potable Water Supply Piping. Header Returned to Svc on 870804)