ML20086U425

From kanterella
Jump to navigation Jump to search
Followup Part 21 Rept Re Defective Mechanical Snubber Capstan Springs Supplied by Pacific Scientific.Affected Utils Listed.Purchasers Have Been Notified & Advised to Work Directly W/Pacific Scientific in Disposition
ML20086U425
Person / Time
Site: Millstone, Davis Besse, Oyster Creek, Comanche Peak, Quad Cities, 05000000
Issue date: 02/24/1984
From: Hovi L
NPS INDUSTRIES, INC.
To: Deyoung R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
REF-PT21-84-136-000 NPSI-01-3825, NPSI-1-3825, PT21-84-136, PT21-84-136-000, NUDOCS 8403070256
Download: ML20086U425 (2)


Text

- - _ _ _

NPS Irdustries. 'nc.

300 Harmor Miadow Boulevard

  • P.O. Box 1535
  • Secaucus. NJ 07094 201/865.3SSO
  • Telex 14 1435

~

February 24, 1984 NPSI-01-3825 U.

'aclear Regulatory Commission Wast.6ngton, DC 20555 i

Attention:

Mr. Richard C. DeYoung Directory, Office of Inspection & Notification l

Subject:

Pacific Scientific 10CFR21 Notification Mechanical Snubber capstan Springs Gentlemen l

This report is a followup te you of the Part 21 notification made by I

Pacific Scientific for the above products.

Identified below are the Receiving plants and snubber serial numbers of the units shipped by NPS Industries, included on the affected serial number list furnished by Pacific Scientific:

s poucatic Nuclear Plant Serial Numbero 1.

Comanche Peak Project snubbers - Complete List available et site, or from this

'i'f 5,

't 'L office on request.-

2.

Davis-Besse Unit 1 19172, 21090, 21094, 21101, 21103, m q,,

b 21106, 24656, 24659, 24674 3.

Millstone Unit 3 18995, 18996, 19387, 19392, 19393, 19395, 19397, 19402, 19404, 19407, y

1940P, 19414, 19416, 19417, 19418,

?

t 13421, 19426, 19428, 19456, 19458, 19459, 19464, 19466, 19472, 19473, 19478, 21398, 21401, 21403, 21408 4.

Oysthr Creek 21340 7 t '\\

5.

Quad. Cities 24613',.24660, 24663, 24665, 24667 35 ' \\['

i The purchasers of those snubbers have received our notification letters as well.as the service and related information we received from Pacific Scientific, and have been advised to work directly with Pacific Scientific on +. heir dispositic.n.

e40307o256 840224 f /7 s a PDR ADOCK 05000219

//

s PDR lQ S

l_

7; l

l' L.

v t-Mr. Richard C. DeYoung February 24, 1984 Capstan Springs NPSI 3825 Page 2 p

I This report is turnished to you to permit us to close out our action file on this matter. Please contact the undersigned if you require any' additional information.

r Sincerely, NPS I STRIES, INC.

~

,-+ d w D Leo Hovi Senior Vice President LHarmg 1

=

k r-9 v

V k

k