- ML17317B288 + (21:56:54, 7 January 2025)
- ML17317B282 + (21:56:55, 7 January 2025)
- ML17317B278 + (21:56:56, 7 January 2025)
- ML17317B277 + (21:56:57, 7 January 2025)
- ML17317B276 + (21:56:58, 7 January 2025)
- 05000316/LER-1979-019-01, /01X-1 on 790519:small Leaks Found in Feedwater Piping to Steam Generator.No Further Description + (21:57:00, 7 January 2025)
- ML17317B274 + (21:57:01, 7 January 2025)
- 05000316/LER-1979-019, Forwards LER 79-019/01X-1 + (21:57:03, 7 January 2025)
- ML17317B270 + (21:57:04, 7 January 2025)
- ML17317B269 + (21:57:04, 7 January 2025)
- ML17317B267 + (21:57:05, 7 January 2025)
- ML17317B266 + (21:57:06, 7 January 2025)
- ML17317B265 + (21:57:07, 7 January 2025)
- 05000315/LER-1979-019-01, /01T-0 on 790519:cracks Found in 16-inch Feedwater Elbows Adjacent to Nozzle Welds Caused Buildup of Nonradioactive Water in Containment Sump.Caused Being Determined.Elbows in Generators Being Replaced + (21:57:09, 7 January 2025)
- 05000315/LER-1979-019, Forwards LER 79-019/01T-0 + (21:57:11, 7 January 2025)
- ML17317B261 + (21:57:12, 7 January 2025)
- ML17317B258 + (21:57:14, 7 January 2025)
- ML17317B259 + (21:57:14, 7 January 2025)
- ML17317B256 + (21:57:15, 7 January 2025)
- ML17317B255 + (21:57:16, 7 January 2025)
- 05000315/LER-1979-033-03, /03L-0 on 790308:monthly Functional Tests for Containment Area Monitor,Containment atmosphere-particulate & Containment atmosphere-gaseous Monitors Were Not Performed.Caused by Daily Assignment Error + (21:57:18, 7 January 2025)
- 05000315/LER-1979-033, Forwards LER 79-033/03L-0 + (21:57:20, 7 January 2025)
- ML17317B250 + (21:57:22, 7 January 2025)
- ML17317B248 + (21:57:22, 7 January 2025)
- ML17317B247 + (21:57:24, 7 January 2025)
- ML17317B246 + (21:57:25, 7 January 2025)
- ML17317B244 + (21:57:26, 7 January 2025)
- ML17317B243 + (21:57:26, 7 January 2025)
- ML17317B242 + (21:57:27, 7 January 2025)
- 05000316/LER-1979-018-03, /03L-0 on 790423:during Investigation of Periodic Alarms for Steam Generator High Steam Line Flow,Controller 2 Py 506B (Turbine Impulse Pressure) Was in Manual Control. Caused by Controller Not Being Returned to Automatic + (21:57:28, 7 January 2025)
- 05000316/LER-1979-018, Forwards LER 79-018/03L-0 + (21:57:30, 7 January 2025)
- ML17317B238 + (21:57:31, 7 January 2025)
- ML17317B236 + (21:57:32, 7 January 2025)
- ML17317B235 + (21:57:33, 7 January 2025)
- ML17317B224 + (21:57:34, 7 January 2025)
- ML17317B223 + (21:57:34, 7 January 2025)
- ML17317B221 + (21:57:35, 7 January 2025)
- ML17317B222 + (21:57:35, 7 January 2025)
- ML17317B220 + (21:57:36, 7 January 2025)
- ML17317B219 + (21:57:37, 7 January 2025)
- ML17317B217 + (21:57:38, 7 January 2025)
- ML17317B216 + (21:57:38, 7 January 2025)
- 05000316/LER-1979-017-03, /03L-0 on 790423:while Performing STP 022, Essential Svc water-142, Essential Svc Valve to 2 Cd Diesel Did Not Seat Properly.Caused by Excessive Wear of Split Disc Hinge Points.Stainless Steel Discs Were Substituted + (21:57:40, 7 January 2025)
- 05000316/LER-1979-017, Forwards LER 79-017/03L-0 + (21:57:42, 7 January 2025)
- 05000315/LER-1979-032-03, /03L-0 on 790416:during Routine Channel Calibr, Bistable FB-510B Trip Point Was Nonconservative W/Respect to Tech Spec Limit.Caused by Excess Drift.Bistable Recalibr + (21:57:43, 7 January 2025)
- 05000315/LER-1979-031-03, /03L-0 on 790419:during Routine Channel Calibr, Bistable Trip Value Discovered Nonconservative W/Respect to Tech Spec Limits.Caused by Excess Drift.Bistable Will Be Repaired + (21:57:46, 7 January 2025)
- 05000315/LER-1979-030-03, /03L-0 on 790417:while Performing Routine Surveillance Test on AB Diesel Generator,Load Conservation Circuitry Did Not Fully Function as Design.Cause Under Investigation + (21:57:48, 7 January 2025)
- ML17317B208 + (21:57:49, 7 January 2025)
- 05000315/LER-1979-029-03, /03L-0 on 790414:cracks Discovered in Divider Barrier Seal.Caused by Excessive Compression of Seal Matl by Steel Plates.Work in Progress to Replace Cracked Sections + (21:57:51, 7 January 2025)
- 05000315/LER-1979-029, Forwards LER 79-029/03L-0 + (21:57:53, 7 January 2025)
- ML17317B203 + (21:57:54, 7 January 2025)