Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML17331A729 + (19:22:33, 7 January 2025)
- ML17331A727 + (19:22:33, 7 January 2025)
- ML17331A726 + (19:22:34, 7 January 2025)
- ML17331A724 + (19:22:35, 7 January 2025)
- ML17331A720 + (19:22:36, 7 January 2025)
- 05000315/LER-1981-011-03, /03L-0:on 810413,while Examining Test Data from Type B & C Leak Rate Tests,Jul 1980 Test for Unit 1 Found to Have Exceeded Allowable Value of Tech Specs.Caused by Faulty NESW Check Valves.Valves Repaired + (19:22:37, 7 January 2025)
- ML17331A718 + (19:22:38, 7 January 2025)
- ML17331A716 + (19:22:40, 7 January 2025)
- NUREG-0674, Advises That Guard Training & Qualification Plan Does Not Meet Requirements of 10CFR73,App B.Requests Revision to 790817 Plan to Replace Pages 1-9 Through 1-17 Re Training Commitments.Response Should Be Submitted within 60 Days + (19:22:41, 7 January 2025)
- ML17331A714 + (19:22:46, 7 January 2025)
- ML17331A710 + (19:22:47, 7 January 2025)
- ML17331A711 + (19:22:47, 7 January 2025)
- ML17331A708 + (19:22:48, 7 January 2025)
- ML17331A707 + (19:22:51, 7 January 2025)
- ML17331A706 + (19:22:52, 7 January 2025)
- IR 05000338/2018301 + (19:22:53, 7 January 2025)
- 05000315/LER-1981-008-03, /03L-0:on 810317,large Piece of Herculite Found Securely Fastened in Canopy Fashion Over Walkway & Plastic Pail Found in Vicinity of Lower Ice Condenser Access Door. Cause Not Determined.Canopy Disassembled & Bucket Removed + (19:22:55, 7 January 2025)
- ML17331A702 + (19:22:56, 7 January 2025)
- ML17331A701 + (19:22:56, 7 January 2025)
- 05000316/LER-1981-007-03, /03L-0:on 810315 During Operation of 2CD Emergency Diesel in Preparation for Surveillance,Hot Starting Air Line Observed.Caused by Valve Damage & Exhaust Expansion Joint Inner Liner Failure.Intake & Exhaust Valves Replaced + (19:22:57, 7 January 2025)
- 05000316/LER-1981-006-03, /03L-0:on 810316,during Automatic Load Sequence Surveillance Test,Safety Injection Sys Relay Timers Exceeded Tolerance Allowed by Tech Specs.Caused by Instrument Drift. Component Cooling Water Pump 2E Timer Replaced + (19:22:59, 7 January 2025)
- ML17331A692 + (19:23:00, 7 January 2025)
- ML17331A691 + (19:23:00, 7 January 2025)
- 05000316/LER-1981-005-01, /01T-0:on 810331,spray Additive Tank Level Found Below Tech Spec Limit During Removal of Magnetrol for 18 Month Surveillance.Caused by Absence of Alarm Due to Contacts Wired Backwards.Tank Refilled + (19:23:02, 7 January 2025)
- ML17331A687 + (19:23:03, 7 January 2025)
- ML17331A688 + (19:23:03, 7 January 2025)
- ML17331A685 + (19:23:04, 7 January 2025)
- ML17331A686 + (19:23:04, 7 January 2025)
- ML17331A684 + (19:23:05, 7 January 2025)
- ML17331A682 + (19:23:06, 7 January 2025)
- ML17331A681 + (19:23:06, 7 January 2025)
- IR 05000315/1980024 + (19:23:07, 7 January 2025)
- ML17331A677 + (19:23:08, 7 January 2025)
- ML17331A676 + (19:23:10, 7 January 2025)
- ML17331A675 + (19:23:11, 7 January 2025)
- ML17331A673 + (19:23:12, 7 January 2025)
- 05000316/LER-1980-039-03, /03L-0:on 800728,low Pressure Alarm Failed to Clear W/Increased Nitrogen Pressure.Cause Not Stated.Refs Encl Response to IE Insp Repts 50-315/80-15 & 50-316/80-14 + (19:23:13, 7 January 2025)
- 05000316/LER-1980-034-03, Containment Isolation Valve NCR-252 Found Not Fully Seated W/Shut Indication in Control Room During Mode 5.Cause Undetermined.Valve Stroke Adjusted + (19:23:15, 7 January 2025)
- 05000315/LER-1980-039, Forwards LER 80-039/03L-0,updated LER 80-034/03X-2 & + (19:23:16, 7 January 2025)
- 05000316/LER-1981-001-04, No Apparent Flow Observed Through Radiation Monitor R-19 from Steam Generator 21. Caused by Bad Diaphragm in roto-meter Flow Regulator.Flow Meters to Radiation Monitor to Be Modified + (19:23:18, 7 January 2025)
- ML17331A664 + (19:23:19, 7 January 2025)
- ML17331A661 + (19:23:20, 7 January 2025)
- ML17331A660 + (19:23:21, 7 January 2025)
- ML17331A659 + (19:23:22, 7 January 2025)
- ML17331A658 + (19:23:23, 7 January 2025)
- ML17331A657 + (19:23:24, 7 January 2025)
- 05000316/LER-1980-035-03, Rod Position Indication for Rod N-9 Did Not Respond Properly While Pulling Shutdown Control Rods in Preparation for Going Critical.Connector on Top of Rod Position Detector Assembly Appeared Stepped on + (19:23:25, 7 January 2025)
- IR 05000315/1980022 + (19:23:27, 7 January 2025)
- ML17331A650 + (19:23:28, 7 January 2025)
- IR 05000315/1980019 + (19:23:30, 7 January 2025)
- ML17331A646 + (19:23:31, 7 January 2025)
- ML17331A644 + (19:23:33, 7 January 2025)