Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000281/LER-1988-017-02, :on 880730,failure of Recirculation Spray Svc Water MOVs Due to Premature Actuation of Torque Switch. Both Valves Declared Inoperable & Tech Spec 3.0.1 Entered on Basis That Both Subsystems Were Inoperable + (00:43:57, 6 January 2025)
- ML18152B110 + (00:43:58, 6 January 2025)
- IR 05000280/1988027 + (00:44:00, 6 January 2025)
- ML18152B107 + (00:44:01, 6 January 2025)
- ML18152B106 + (00:44:02, 6 January 2025)
- ML18152B104 + (00:44:03, 6 January 2025)
- ML18152B103 + (00:44:04, 6 January 2025)
- ML18152B102 + (00:44:05, 6 January 2025)
- IR 05000280/1988031 + (00:44:06, 6 January 2025)
- ML18152B099 + (00:44:08, 6 January 2025)
- ML18152B098 + (00:44:08, 6 January 2025)
- 05000280/LER-1988-008-01, :on 880309,low Head Safety Injection Pump Inoperable Due to Failed Motor Leads Caused by Improper Splicing.Leads Repaired & Motor Replaced & Tested Satisfactorily + (00:44:10, 6 January 2025)
- ML18152B096 + (00:44:11, 6 January 2025)
- ML18152B095 + (00:44:12, 6 January 2025)
- ML18152B094 + (00:44:13, 6 January 2025)
- IR 05000338/1988003 + (00:44:21, 6 January 2025)
- ML18152B091 + (00:44:22, 6 January 2025)
- IR 05000280/1988020 + (00:44:25, 6 January 2025)
- ML18152B088 + (00:44:26, 6 January 2025)
- ML18152B087 + (00:44:27, 6 January 2025)
- ML18152B085 + (00:44:27, 6 January 2025)
- ML18152B083 + (00:44:29, 6 January 2025)
- 05000280/LER-1988-024, :on 880711,16 Individual Rod Position Indicators for Eight Rods in Each Shutdown Bank a & B Differed from Group Demand Step Counter by Greater than 12 Steps.Caused by Drift in Subj Indicators + (00:44:30, 6 January 2025)
- 05000280/LER-1988-026, :on 880714,inoperable Individual Rod Position Indicators (Irpi) Noted.Caused by Instrument Drift.Affected Irpis Adjusted to Required Tech Spec Tolerance + (00:44:32, 6 January 2025)
- IR 05000280/1988024 + (00:44:36, 6 January 2025)
- ML18152B078 + (00:44:38, 6 January 2025)
- IR 05000280/1988018 + (00:44:44, 6 January 2025)
- ML18152B075 + (00:44:46, 6 January 2025)
- 05000280/LER-1988-022, :on 880710,unit Ramped Down to Shutdown.Caused by MOV-CS-101B Leakage Due to Lost Motion in Shaft & Linkage Between Motor Operator & Shaft.Valve Disassembled & Valve Seat & O-rings Replaced + (00:44:47, 6 January 2025)
- TAC:42867 + (00:44:49, 6 January 2025)
- ML18152B073 + (00:44:49, 6 January 2025)
- ML18152B072 + (00:44:51, 6 January 2025)
- 05000280/LER-1988-027, :on 880714,Tech Spec That Required Sampling Had Not Been Performed within Required Time Frame.Caused by Step 3 of Svc Water Contamination Analysis Procedure Being Performed on Old Data.Samples Obtained + (00:44:52, 6 January 2025)
- ML18152B070 + (00:44:53, 6 January 2025)
- ML18152B068 + (00:44:54, 6 January 2025)
- ML18152B067 + (00:44:55, 6 January 2025)
- 05000280/LER-1988-019-01, :on 880625,emergency Diesel Generator 1 Unintentionally Started.Caused by Technician Accidentally Shorting Fast Start Relay.Electrician Counseled to Proceed Cautiously When Installing Jumpers + (00:44:56, 6 January 2025)
- ML18152B061 + (00:44:57, 6 January 2025)
- ML18152B059 + (00:44:58, 6 January 2025)
- ML18152B060 + (00:44:58, 6 January 2025)
- ML18152B057 + (00:44:59, 6 January 2025)
- ML18152B055 + (00:45:00, 6 January 2025)
- ML18152B053 + (00:45:02, 6 January 2025)
- ML18152B052 + (00:45:02, 6 January 2025)
- ML18152B047 + (00:45:03, 6 January 2025)
- ML18152B048 + (00:45:03, 6 January 2025)
- ML18152B046 + (00:45:04, 6 January 2025)
- ML18152B044 + (00:45:05, 6 January 2025)
- ML18152B042 + (00:45:06, 6 January 2025)
- 05000280/LER-1988-017-01, :on 880606,discovered Debris in Temporary Discharge Cone Strainer & Recirculation Spray Sump Pumps. Caused by Inadequate Insp Program.Containment Sump & Pump Screen Surveillance Will Be Implemented + (00:45:07, 6 January 2025)
- ML18152B039 + (00:45:09, 6 January 2025)