Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20214X282 + (04:28:18, 4 December 2024)
- 05000374/LER-1987-004-08, :on 870401,53 Safety Related Snubbers Failed to Meet Functional Test Acceptance Limits During Tech Spec Surveillance.Causes & Corrective Actions for Each Snubber Listed + (04:28:21, 4 December 2024)
- ML20214X278 + (04:28:21, 4 December 2024)
- ML20214X276 + (04:28:22, 4 December 2024)
- ML20214X274 + (04:28:23, 4 December 2024)
- ML20214X275 + (04:28:23, 4 December 2024)
- ML20214X272 + (04:28:24, 4 December 2024)
- 05000410/LER-1986-002-01, :on 861104,four Source Range Monitors (Srms) Downscale Channels Placed in Bypassed State When Jumpers Installed to Clear SRM Downscale Rod Blocks.Caused by Human Error & Procedure Deficiency.Procedure Revised + (04:28:26, 4 December 2024)
- ML20214X269 + (04:28:26, 4 December 2024)
- ML20214X267 + (04:28:27, 4 December 2024)
- ML20214X265 + (04:28:28, 4 December 2024)
- ML20214X263 + (04:28:29, 4 December 2024)
- ML20214X259 + (04:28:30, 4 December 2024)
- IR 05000341/1987023 + (04:28:31, 4 December 2024)
- ML20214X257 + (04:28:32, 4 December 2024)
- ML20214X250 + (04:28:33, 4 December 2024)
- ML20214X253 + (04:28:33, 4 December 2024)
- PLA-2857, Responds to Generic Ltr 87-06, Periodic Verification of Leak Tight Integrity of Pressure Isolation Valves. Leakage Rate Testing Frequencies & Acceptance Criteria Provided in Tech Spec 3/4.4.3.2 + (04:28:34, 4 December 2024)
- IR 05000362/1987013 + (04:28:35, 4 December 2024)
- IR 05000413/1986035 + (04:28:37, 4 December 2024)
- ML20214X242 + (04:28:38, 4 December 2024)
- ML20214X236 + (04:28:39, 4 December 2024)
- ML20214X234 + (04:28:40, 4 December 2024)
- ML20214X231 + (04:28:41, 4 December 2024)
- ML20214X232 + (04:28:41, 4 December 2024)
- ML20214X228 + (04:28:42, 4 December 2024)
- ML20214X223 + (04:28:43, 4 December 2024)
- ML20214X222 + (04:28:43, 4 December 2024)
- ML20214X219 + (04:28:44, 4 December 2024)
- ML20214X218 + (04:28:45, 4 December 2024)
- 05000424/LER-1987-026, :on 870510,main Feedwater Isolation & Turbine Trip Occurred Resulting in Actuation of Both motor-driven Auxiliary Feedwater Pumps.Caused by Inadequate Procedure. Operating Procedure Revised + (04:28:46, 4 December 2024)
- ML20214X214 + (04:28:47, 4 December 2024)
- ML20214X213 + (04:28:48, 4 December 2024)
- 05000302/LER-1985-034, :on 850809,RCS Pressure Raised Above 750 Psig W/O Meeting Required Operability Surveillances Per Tech Spec 3.5.1.a.Caused by Inadequate Procedure.Procedure Revised.W/ + (04:28:50, 4 December 2024)
- ML20214X211 + (04:28:50, 4 December 2024)
- IR 05000277/1986023 + (04:28:52, 4 December 2024)
- ML20214X207 + (04:28:52, 4 December 2024)
- 3F0687-05, Documents Supplemental Info Re Relief Request 140 Concerning Reactor Vessel Support Skirt Weld Exam.Visual Exam of Weld Root Would Be Equivalent to Exam of Weld Crown & Satisfies Requirement to Perform Visual Exam of Reactor Vessel Weld + (04:28:54, 4 December 2024)
- ML20214X196 + (04:28:55, 4 December 2024)
- ML20214X197 + (04:28:55, 4 December 2024)
- ML20214X195 + (04:28:56, 4 December 2024)
- 05000440/LER-1987-030, :on 870501,manual Reactor Scram Initiated Due to Loss of Reactor Feedwater.Caused by Failure of Air Lines for Condensate Flow Control Valve from Vibration.Metal Air Lines,Addl Valve & Pipe Supports Will Be Installed + (04:28:58, 4 December 2024)
- IR 05000336/1985098 + (04:29:27, 4 December 2024)
- ML20214X190 + (04:29:28, 4 December 2024)
- ML20214X187 + (04:29:31, 4 December 2024)
- ML20214X180 + (04:30:05, 4 December 2024)
- ML20214X184 + (04:30:05, 4 December 2024)
- ML20214X177 + (04:30:06, 4 December 2024)
- ML20214X176 + (04:30:07, 4 December 2024)
- ML20214X175 + (04:30:07, 4 December 2024)
- ML20214X173 + (04:30:08, 4 December 2024)
- 05000440/LER-1987-029, :on 870501,during Containment Venting,Operators Overrode Interlock to Maintain RCIC Suction Transfer W/O Reducing Suppression Pool,Violating Interlock Time Per Tech Spec.Operators Counseled.Design Change Planned + (04:30:10, 4 December 2024)