List of results
- 05000271/LER-1980-006-01, /01T-0:on 800122,received Low Flow Alarm on Off Gas Sampling Sys.Flow Disturbance Rendered Both Radiation Monitors 17-150A & B Inoperable.Apparently Caused by Flow Blockage.Flow Increased,Clearing Blockage + (13:59:25, 3 January 2025)
- 05000271/LER-1980-006, Forwards LER 80-006/01T-0 + (13:59:33, 3 January 2025)
- ML19262C268 + (13:59:35, 3 January 2025)
- 05000285/LER-1980-001-03, /03L-0:800102,while Operating at Approx 98% Power, Breaker Feeding Containment Cooling Fan Motor VA-3B Tripped.Caused by Trip Units Out of Calibr.Units A&C Were Replaced,Calibr & Tested Satisfactorily + (14:00:09, 3 January 2025)
- ML19262C265 + (14:00:11, 3 January 2025)
- 05000285/LER-1980-001, Forwards LER 80-001/03L-0 + (14:00:36, 3 January 2025)
- ML19262C260 + (14:00:44, 3 January 2025)
- 05000271/LER-1980-004-03, /03L-0:on 800109,power Supply Overheated & Failed, Resulting in Loss of All Rod Position Indication,Rpis Alarm,All Rod Drift Alarms,Rwm Rod Block & Overtravel Alarm. Caused by Failure of Cooling Fan in Power Supply + (14:00:48, 3 January 2025)
- ML19262C257 + (14:00:52, 3 January 2025)
- ML19262C253 + (14:00:54, 3 January 2025)
- 05000271/LER-1980-004, Forwards LER 80-004/03L-0 + (14:00:56, 3 January 2025)
- ML19262C244 + (14:00:58, 3 January 2025)
- ML19262C241 + (14:01:00, 3 January 2025)
- 05000334/LER-1980-002-01, /01T-0:on 800117,during Operational Mode 5,w/RCS Temp at 100 F & Atmospheric Pressure & RCS Level mid-loop W/ RHR Flow at 1,700 Gpm,Reactor Vessel Vent Educator Was in Svc,Causing Negative Pressure + (14:01:02, 3 January 2025)
- ML19262C239 + (14:01:04, 3 January 2025)
- 05000334/LER-1980-002, Forwards LER 80-002/01T-0 + (14:01:13, 3 January 2025)
- ML19262C236 + (14:01:14, 3 January 2025)
- ML19262C235 + (14:01:16, 3 January 2025)
- 05000259/LER-1980-003-03, /03L-0:on 800112,while Performing Local Leak Rate Testing During Refueling Shutdown,Path Leakage Through MSIVs for 3 of 4 Main Steam Lines Exceeded Leak Rate Per Tech Specs.Caused by Normal Wear & Erosion + (14:01:19, 3 January 2025)
- ML19262C233 + (14:01:21, 3 January 2025)
- 05000259/LER-1980-003, Forwards LER 80-003/03L-0 + (14:01:23, 3 January 2025)
- 05000271/LER-1980-003-03, /03L-0:on 800107,discovered That Air Sample Station 3.3 Was Not Drawing Continuous Sample.No Sample Obtained 791230-800107.Caused by Tygon Tube Being Disconnected from Gas Flow Meter to Air Sampling Head + (14:01:27, 3 January 2025)
- IR 05000213/1979006 + (14:01:56, 3 January 2025)
- 05000271/LER-1980-003, Forwards LER 80-003/03L-0 + (14:02:01, 3 January 2025)
- ML19262C226 + (14:02:05, 3 January 2025)
- ML19262C224 + (14:02:08, 3 January 2025)
- ML19262C223 + (14:02:09, 3 January 2025)
- ML19262C222 + (14:02:10, 3 January 2025)
- ML19262C221 + (14:02:11, 3 January 2025)
- 05000348/LER-1980-003-03, /03L-0:on 800104,determined Surveillance Test FNP-1-STP-109 Re Power Range Neutron Flux Channel Calibr Not Performed During Required Interval.Caused by Personnel Error.Test Performed & Personnel Instructed + (14:02:14, 3 January 2025)
- 05000348/LER-1980-001-03, /03L-0:on 800106,fuel Storage Pool Area Radiation Monitor Declared Inoperable Due to hi-alarm Being Set Above Tech Specs.Caused by Setpoint Drift.Instrument Recalibr + (14:02:18, 3 January 2025)
- ML19262C217 + (14:02:20, 3 January 2025)
- ML19262C216 + (14:02:22, 3 January 2025)
- ML19262C215 + (14:02:24, 3 January 2025)
- ML19262C214 + (14:02:29, 3 January 2025)
- ML19262C213 + (14:02:31, 3 January 2025)
- ML19262C212 + (14:02:34, 3 January 2025)
- ML19262C211 + (14:02:36, 3 January 2025)
- ML19262C210 + (14:02:37, 3 January 2025)
- ML19262C209 + (14:02:39, 3 January 2025)
- ML19262C206 + (14:02:42, 3 January 2025)
- ML19262C204 + (14:02:43, 3 January 2025)
- ML19262C203 + (14:02:44, 3 January 2025)
- ML19262C202 + (14:02:45, 3 January 2025)
- ML19262C200 + (14:02:47, 3 January 2025)
- ML19262C199 + (14:02:49, 3 January 2025)
- ML19262C198 + (14:02:52, 3 January 2025)
- ML19262C196 + (14:02:53, 3 January 2025)
- ML19262C195 + (14:02:57, 3 January 2025)
- ML19262C193 + (14:02:59, 3 January 2025)
- TXX-3071, Responds to NRC Re Violations Noted in IE Insp Repts 50-445/79-18 & 50-446/79-18.Corrective Actions: Improvements Made in Site Training Program to Emphasize Insp Methods & Techniques & QA Procedures Revised + (14:03:01, 3 January 2025)