Forwards IE Circular 80-01, Svc Advice for GE Induction Disc Relays. No Response Required
ML19262C209
Person / Time
Site: Farley  
Issue date: 01/17/1980
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Clayton F
ALABAMA POWER CO.
References
NUDOCS 8002070327
Download: ML19262C209 (2)


Text

~~

p neo

/

UNITED STATES o

f ',3,

1* *%

NUCLEAR REGULATORY COMMISSION A ),E REGION 11 d'[

101 MARIETTA ST N.W,.SulTE 3100 o

%g.

ATLANTA, G EORGI A 30303 JAN 171923 In Reply Refer To:

R

  • Pq 50-348 i

Alabama Power Company Attn:

F. L. Clayton, Jr.

Senior Vice President Post Office Bo;t 2641 Birmingham, Alabama 35291 Centlemen:

The enclosed IE Circular No. 80-01 is forwarded to you for information and if applicable necessary action in accordance to the attached General Electric Company Service Advice 721-162.2.

No written response to this Circular is required.

If you have any questions related to the subject, please contact this office.

Sincerely,

_3,'

q----~.

~

James P. O'Reill Director

^

Enclosures:

1.

IE Circular No. 80 2.

List of Recently Issued IE Circulars 1925 315 8002070

JAK 17193; Alabama Power Company.

cc w/ enc 1:

A. R. Barton Executive Vice President

{

Post Office Box 2641 Birmingham, Alabama 35291 J. T. Young Vice President-Production Post Office Box 2641 Birmingham, Alabama 35291 C. Biddinger, Jr.

M anager-Corporate Quality Assurance Post Office Box 2641 Birmingham, Alabams 35291 H. O. Thrash Manager-Nuclear Generation Post Office Box 2641 Birmingham, Alabama 35291 H. G. Hairston, III Plant Manager Drawer 470 Ashford, Alabama 36312 R. E. Hollands, Jr.

QA Supervisor Post Office Box U Ashford, Alabama 36312 t925 316

UNITED STATES SSINS No.:

6830 NUCLEAR REGULATORY COMMISSION Accessions No.-

~

OFFICE OF INSPECTION AND ENFORCEMENT 7912190644 WASHINGTON, D.C.

20555 January 17, 1980 IE Circular No. 80-01 SERVICE ADVICE FOR GENERAL ELECTRIC INDUCTION DISC RELAYS Alabama Power Company reported to the NRC on October 16, 1979 a potential problem with certain General Electric Company induction disc type protective relays. A higher than normal pick-up value was caused by petroleum jelly lubricant which under high temperature conditions can migrate to the backstop. At room temper-ature the lubricant can become adhesive and cause pickup values to be higher than setpoint values.

General Electric (GE) laboratory confirmed some higher aan normal pickup values and recommended that users determine whether relays meeting the following criteria are in use at their facilities:

(1) Relay type:

IAC, IAV, ICR, or IJCV, AND (2) The relay date code (which is printed on a 3/4" x 3/8" sticker af fixed to the relay cradle) has a number less than 50, followed by any of the following two letter codes:

(a) Any first letter followe3 by II, J, K, L, or M; or (b) The letter combinations AN, BN, CN, DN, EN, DG, EG, FG, CG, IIG, JG, KG, LG or MG.

For example, 31GK would be considered, while 50 GK or 231IN would not be considered.

Experience has shown that the cleaning procedure recommended in GE Service Advice 721-162.1 may not in all cases remove all of the petroleum jelly wh ch is lodged in place.

Based on the above, licensees are advised to apply G.E. Service Advice 721-162.2 (Enclosure A) to all relays that fall within the above two criteria.

No written response to this Circular is required.

If you desire additional information regarding this matter contact the Director of the appropriate NRC Regional Office.

Atta cluncat:

GE Service Advice 721-162.2 DUPLICATE DOCUMENT Entire document previcusly entered into system under: