- ML19340D605 + (23:05:00, 24 December 2024)
- ML19340D604 + (23:05:01, 24 December 2024)
- ML19340D601 + (23:05:03, 24 December 2024)
- ML19340D603 + (23:05:03, 24 December 2024)
- ML19340D599 + (23:05:04, 24 December 2024)
- ML19340D600 + (23:05:04, 24 December 2024)
- 05000346/LER-1980-084-03, /03L-0:on 801128,switch PSL107D Would Not Reset After Actuating on Low Steam Pressure & Auxiliary Feedwater Sys Declared Inoperable.Caused by Defective Actuation Switch & Actuator in PSL107D.Parts Replaced + (23:05:06, 24 December 2024)
- ML19340D597 + (23:05:08, 24 December 2024)
- 05000338/LER-1980-100-03, /03L-0:on 801201,LI-1474 Steam Generator a Level Channel 1 Indicated Higher than Average of Three Channels. Caused by High Transmitter Output Due to Leaking Root Isolation Valve.Will Be Repaired in Next Refueling Outage + (23:05:09, 24 December 2024)
- ML19340D595 + (23:05:10, 24 December 2024)
- 05000338/LER-1980-103-03, /03L-0:on 801113,containment Matl Seismic Recorder ER-002 Failed Periodic Test PT-39.5.Caused by Electronic Fault in Field Sending Unit.Total Component Replaced + (23:05:11, 24 December 2024)
- ML19340D593 + (23:05:12, 24 December 2024)
- 05000346/LER-1980-085-03, /03L-0:on 801128 Borated Water Storage Tank Low Level Bistable Tripped.Apparently Caused by Loose Connection at Borated Water Storage Tank Level Transmitter.Lead Tightened + (23:05:14, 24 December 2024)
- ML19340D591 + (23:05:15, 24 December 2024)
- 05000338/LER-1980-103, Forwards LER 80-103/03L-0 + (23:05:16, 24 December 2024)
- ML19340D588 + (23:05:17, 24 December 2024)
- 05000278/LER-1980-028-01, /01T-0:on 801203,HPCI Steam Supply Valve, MO-3-23-14,failed to Fully Close.Caused by HPCI Sys Being Inoperable for Valve Insp.Valve Reassembled & Tested + (23:05:19, 24 December 2024)
- ML19340D586 + (23:05:21, 24 December 2024)
- 05000346/LER-1980-085, Forwards LER 80-085/03L-0 + (23:05:22, 24 December 2024)
- 05000278/LER-1980-028, Forwards LER 80-028/01T-0 + (23:05:23, 24 December 2024)
- 05000346/LER-1980-084, Forwards LER 80-084/03L-0 + (23:05:25, 24 December 2024)
- ML19340D579 + (23:05:27, 24 December 2024)
- 05000330/LER-1980-100, Forwards LER 80-100/03L-0 + (23:05:29, 24 December 2024)
- ML19340D574 + (23:05:29, 24 December 2024)
- 05000155/LER-1980-039-03, /03L-0:on 801127,check Valve Inside Containment in 3-inch Treated Waste Line Found Leaking in Excess of Test Criteria.Caused by Excessive Wear on Disc Pin of Tilting Disc Check Valve.Seat & Disc Components Replaced + (23:05:31, 24 December 2024)
- 05000155/LER-1980-039, Forwards LER 80-039/03L-0 + (23:05:33, 24 December 2024)
- ML19340D568 + (23:05:34, 24 December 2024)
- ML19340D567 + (23:05:35, 24 December 2024)
- ML19340D566 + (23:05:36, 24 December 2024)
- ML19340D564 + (23:05:36, 24 December 2024)
- ML19340D563 + (23:05:37, 24 December 2024)
- ML19340D562 + (23:05:41, 24 December 2024)
- ML19340D561 + (23:05:42, 24 December 2024)
- ML19340D560 + (23:05:43, 24 December 2024)
- ML19340D559 + (23:05:44, 24 December 2024)
- ML19340D557 + (23:05:46, 24 December 2024)
- ML19340D558 + (23:05:46, 24 December 2024)
- ML19340D556 + (23:05:47, 24 December 2024)
- ML19340D555 + (23:05:48, 24 December 2024)
- IR 05000344/1980027 + (23:05:49, 24 December 2024)
- ML19340D553 + (23:05:51, 24 December 2024)
- ML19340D551 + (23:05:51, 24 December 2024)
- ML19340D549 + (23:05:52, 24 December 2024)
- ML19340D548 + (23:05:53, 24 December 2024)
- ML19340D547 + (23:05:54, 24 December 2024)
- ML19340D545 + (23:05:55, 24 December 2024)
- ML19340D544 + (23:05:56, 24 December 2024)
- ML19340D543 + (23:05:57, 24 December 2024)
- ML19340D542 + (23:05:58, 24 December 2024)
- ML19340D541 + (23:05:59, 24 December 2024)
- ML19340D540 + (23:05:59, 24 December 2024)