Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19350F108 + (23:58:04, 23 December 2024)
- ML19350F106 + (23:58:06, 23 December 2024)
- ML19350F105 + (23:58:07, 23 December 2024)
- ML19350F104 + (23:58:08, 23 December 2024)
- ML19350F103 + (23:58:09, 23 December 2024)
- 05000277/LER-1981-031-03, /03L-0:on 810518,reactor Coolant Temp Exceeded Tech Spec Limit Before Shutdown Cooling,Secured to Permit Maint of Valve MO-17,could Be re-established.Caused by Lack of Timely Coordination Between Operations & Maint Personnel + (23:58:11, 23 December 2024)
- IR 05000352/1981001 + (23:58:13, 23 December 2024)
- ML19350F099 + (23:58:15, 23 December 2024)
- ML19350F098 + (23:58:16, 23 December 2024)
- ML19350F097 + (23:58:17, 23 December 2024)
- ML19350F095 + (23:58:19, 23 December 2024)
- ML19350F094 + (23:58:19, 23 December 2024)
- ML19350F093 + (23:58:20, 23 December 2024)
- 05000325/LER-1981-040-03, /03L-0:on 810602,found Required Surveillance for ECCS Reactor Low Pressure Channel Calibr & Functional Test Not Performed for Actuation Instruments by 810524.Caused by Personnel Error.Personnel Counseled + (23:58:24, 23 December 2024)
- 05000325/LER-1981-040, Forwards LER 81-040/03L-0 + (23:58:27, 23 December 2024)
- ML19350F089 + (23:58:40, 23 December 2024)
- ML19350F088 + (23:58:43, 23 December 2024)
- 05000327/LER-1981-061-03, /03L-0:on 810522,RHR Loop a Miniflow Valve, 1-FCV-74-12,declared Inoperable.Caused by Geared Limit Drive Hypoid Gear Cocked on Drive Sleeve,Out of Step W/Geared Limit Switch.Gear Realigned & Properly Installed on 810523 + (23:58:45, 23 December 2024)
- 05000327/LER-1981-061, Forwards LER 81-061/03L-0 + (23:58:49, 23 December 2024)
- ML19350F084 + (23:58:50, 23 December 2024)
- ML19350F083 + (23:58:52, 23 December 2024)
- ML19350F082 + (23:58:53, 23 December 2024)
- ML19350F081 + (23:58:55, 23 December 2024)
- ML19350F080 + (23:58:56, 23 December 2024)
- ML19350F079 + (23:58:58, 23 December 2024)
- ML19350F078 + (23:59:02, 23 December 2024)
- ML19350F077 + (23:59:03, 23 December 2024)
- ML19350F076 + (23:59:05, 23 December 2024)
- ML19350F075 + (23:59:06, 23 December 2024)
- ML19350F074 + (23:59:07, 23 December 2024)
- ML19350F073 + (23:59:08, 23 December 2024)
- ML19350F072 + (23:59:09, 23 December 2024)
- ML19350F071 + (23:59:11, 23 December 2024)
- ML19350F070 + (23:59:12, 23 December 2024)
- ML19350F069 + (23:59:13, 23 December 2024)
- 05000296/LER-1981-027-03, /03L-0:on 810525,reactor Water Level Instruments Indicated Full Upscale & Were Declared Inoperable.Caused by Loss of Ref Leg on Water Column for Undetermined Reasons. Water Leg Backfilled & Instruments Returned to Operation + (23:59:15, 23 December 2024)
- ML19350F067 + (23:59:17, 23 December 2024)
- 05000296/LER-1981-027, Forwards LER 81-027/03L-0 + (23:59:19, 23 December 2024)
- 05000259/LER-1981-024-03, /03L-0:on 810518,train C to Flow Switch for Standby Gas Treatment Sys Was Found Inoperable During Calibr of Switches.Caused by Electronic Failure of Dwyer Photohelic Pressure Switch.Switch Replaced + (23:59:21, 23 December 2024)
- 05000339/LER-1981-042-03, /03L-0:on 810522,boric Acid Storage Tank Concentration Was Below Required Limit.Caused by Blender Valve FCV-2113A Mistakenly Being Operated in Auto Allowing Water to Backflow Into Sys.Tank Concentration Restored + (23:59:25, 23 December 2024)
- 05000259/LER-1981-024, Forwards LER 81-024/03L-0 + (23:59:28, 23 December 2024)
- 05000339/LER-1981-042, Forwards LER 81-042/03L-0 + (23:59:30, 23 December 2024)
- ML19350F058 + (23:59:32, 23 December 2024)
- ML19350F057 + (23:59:33, 23 December 2024)
- ML19350F055 + (23:59:34, 23 December 2024)
- ML19350F056 + (23:59:34, 23 December 2024)
- BSEP-81-1203, Forwards Monthly Operating Repts for May 1981 + (23:59:35, 23 December 2024)
- ML19350F052 + (23:59:38, 23 December 2024)
- ML19350F051 + (23:59:40, 23 December 2024)
- ML19350F050 + (23:59:41, 23 December 2024)
- ML19350F048 + (23:59:42, 23 December 2024)