ML19350F079

From kanterella
Jump to navigation Jump to search
Forwards Request for Addl Info for Review of SEP Topics III-2 Re Wind & Tornado loadings,III-7.B Re Design Codes, Design Criteria,Load Combinations & Reactor Cavity Design & III-6 Re Seismic Design Considerations
ML19350F079
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
Issue date: 06/17/1981
From: Crutchfield D
Office of Nuclear Reactor Regulation
To: Hoffman D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
References
TASK-03-02, TASK-03-06, TASK-03-07.B, TASK-RR LSO5-81-06-064, NUDOCS 8106240175
Download: ML19350F079 (5)


Text

.

~

~.

g.

g.

June 17,1981 4

' Docket No. 50-155 e

4 LS05-81 06-064 0

~

g$

Lb 5 2 3198 l

t

  • "'4 % - - 1 s Mr. David P. Hoffman

/

Nuclear Licensing Administrator

[

\\

Consumers Power Company 1945 W Parnall Road t

Jackson, Michigan 49201

Dear Mr. Hoffman:

SUBJECT:

SYSTEMATIC EVALUATION PROGRAM TOPICS, III-2, WIND AND TORNADO LOADINGS, III-7.B. DESIGN CODES, DESIGN CRITERIA, LOAD CO M INATIONS AND REACTOR CAVITY DESIGN AND III-6, SEISMIC DESIGN CONSIDERATIONS - BIG ROCK POINT We are continuing our review of the above topics and require the additional information described in the enclosures. The information will be used to review the capability of your plant to resist seismic loads in combination l

with other loads and to resist tornado wird and pressure loads.

It will also allow us to identify structural elements affected by code changes.

The information is required by NRC contractors who are performing analyses on tha above subjects.

In order for thr. contractors to maintain their schedules, please provida a copy of your responses directty to the contrac-tors as indicated below and one copy to the NRC.

You are requested to submit the additional infonnation described in the enclosure within 30 days of your receipt of this letter. Please refer to the topic numbers in your response.

Mail the responses to Enclosure 1 to:

Ting Lo Lawrence Livemore Laboratory Mail Station L-90 P. O. Box 808 Livermore, California 94550 l

Mail the responses to Enclosure 2 to:

Franklin Research Center Division of the Franklin Institute Benjamin Franklin Parkway 8106240l7f Philadelphia, Pa.

19103 g

ATTENTION:

D. Barrett I M **l3 e,,.c p J

DATE) oc re.u re ie son.= v c2" OFFICIAL RECORD COPY

'e '*- =

N-5 Y

(

l

[

f..

Mail one copy of all responses to:

U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Sincerely, Dennis i Crutchfield, Chief Operating. e ctors Branch No. 5 Division of Licensing

Enclosures:

As stated cc w/ enclosures:

See next page SEP

/

PYC

/

6//r/81 r'. ~ d A

hI a

emerM. SEP, S:DLN.....S..E.PB :DL...F SEPB :D.l'. ' 8f...

ORBd5,.:.n.(:.PMOR(

A A:DL DL

.g,

' * * ' >..CPe.rs.i.nko.: dk,8Hermann,

WR.us,s,elj...,,

3*WPaulson..

Ddr. chfield G tnas

../l /,81 6/..b.../. 81 om>

6./.1.6../. 81.....

. 6. /.. '. c../. 81......

6../..(, L../. 81..

6./.4.f../81 6

i c.'c reau 24 s.io sor saev czao OFFICIAL RECORD COPY

. e m-m2 d

B j

),'

^

UNITED STATES y ) g(, i NUCLEAR REGULATORY COMMISSION C

WASHINGTON, D. C 20555

  • /- gi June 17,1931--

Docket No. 50-155-LS05-81 06-064 Mr. David P. Hoffman Nuclear. Licensing Administrator -

Consumers Power Company 1945 W Parnall Road Jackson, Michigan 49201

Dear Mr. Hoffman:

SUBJECT:

SYSTEMATIC EVALUATION PROGRAM TOPICS, III-2, WIND AND TORNADO LOADINGS,-III-7.B,. DESIGN CODES, DESIGN CRITERIA, LOAD COMBINATIONS AND REACTOR CAVITY DESIGN AND III-6, SEISMIC DESIGN CONSIDERATIONS - BIG ROCK POINT We ire continuing our review of the above topics and require the additional information described in the enclosures. The information will be used to review the capability of your plant to resist seismic loads in combination with other loads and to resist tornado wind and pressure loads.

It will also allow us to identify structural elements affected by code changes.

The information is required by NRC contractors who are performing analyses on the above subjects.

In order for the contractors to maintain their schedules, please provide a copy of your responses directly to the -contrac-tors as indicated below and one copy to the NRC.

You are requested to submit the additional information described in the enclosure within 30 days of your receipt of this letter.

Please refer to the topic numbers in your response.

Mail the responses to Enclosure 1 to Ting Lo Lawrence Livermore Laboratory Mail Station L-90 P. O. Box 808 Livermore, California 94550 Mail the responses to Enclosure 2 to:

Franklin Research Center Division of the Franklin Institute Benjamin Franklin Parkway Philadelphia, Pa.

19103 ATTENTION:

D. Barrett T. Stilwell m

p

_,,i w

g

,7--3*

--*m'-g w-w

-wy s-T W

--y e-g

. c..

.... S e-

. Mail one copy of. all.- responses to:

U. S. Nuclear Regulatory Conunission -

~ ~

Washington, D.C.

20555

(

.. Sincerely,

. Dennis M. Crutchfield, Chief Operating.Reacto'rs Branch No. 5

~

Division of Licensing

Enclosures:

As. stated.

~

. cc w/ enclosures:

-- See next page t

+

4 k

I f

1 i

w t

4 e

t i

g:

I 4

r a

t i 4 e-yr-#w-v=%&%y=-,+

-v we g

ern er <,i-wea v,%p,r, wm ween www-wrg ~ --,- p + cyg, +y e

  • get w g, w g. y-g *wwg wg, y e epw w =

,g--

e-9--w,,

y, g -ym y yw q%3, n

,g, 9-y -ewn m.m.9,, w~r wiyg

a Mr.- David P. Hoffman cc.

Mr. Paul' A. Perry, Secretary U.' S. Environmental Protection 1

Consumers Power Cocpany Agency 212 West Michi_gan Avenue Federal Activities Branch Jackson, Michigan 49201 Region V Office ATTN: EIS COORDINATOR Judd L. Bacon, Esquire 230 South Dearborn Street Consumers Power Cocpany Chicago, Illinois 60604 212 West Michigan Avenue Jackson, Michigan 49201 Ferbert Grossman, Esq., Chaircun Atomic Safety and Licensing Board Joseph Gallo, Esquire U. S. Nuclear Regulatory Comission Isham, Lincoln & Beale Washington, D. C.

20555 1120 Connecticut Avenue Room 325 Dr. Oscar H. Paris Washington, D. C.

20036 Atomic Safety and Licensing Board

'U. S. Nuclear Regulatory Comission Peter W. Steketee, Esquire Washington, D. C.

20555 505 Peoples Suilding Grand Rapids, Michigan 49503 Mr. Frederick J. Shon Atomic Safety and Licensing Board Alan 5. Rosenthal, Esq., Chairman U. S. Nuclear Regulatory Comission-Atomic Safety & Licensing Appeal Board Washington, D. C.

20555 U. S. Nuclear Regulatory Comission Washington, D. C.

20555 Big Rock Point Nuclear. Power Plant ATTN: Mr. C. J. Hartman Mr. John O'Neill,11 Plant Superintendent Route 2. Box 44 Charlevoix, Michigan 49720 Maple City, Michigan 49564 Christa-Maria Charlevoix Public Library Route 2, Box 10SC l

107 Clinton Street Charlevoix, Michigan 49720

' Charlevoix, Michigan l

William J. Scanlon, Esquire l

Chairman 2034 Pauline Boulevard County Board of Supervisors Ann Arbor, Michigan 48103 l

Charlevoix County L

Charlevoix, Michigan 49720 Ret ' jent Inspector

[

Big Rock Point Plant Office of the Governor (2) c/o U.S. NRC l

Room 1 - Capitol Building RR #3, Box 600 Lansing, Michigan 48913 Charlevoie, Michigan 49720 Director, Criteria and Standards Mr. Jim E. Mills Division Reute 2, Box 10SC l

Office of Radiation Programs Charlevoix, Michigan 49720 (ANR-460)

U. S. Environmental Protection Theras S. M: ore Agency Atomic Safety & Licensing Appeal Board l

Washington, D. C.

20460 U. S. Nuclear Regulatory Comission t

Washington, D. C.

20555 P00R M Ei n

ENCLOSURE 1 Containment (Rerctor Building) Structure

'l.

Drawing index including titles (or descriptions) and corresponding drawing numbers.

2.

Layout and structural drawings with sufficient structural information on the containment and its support and of the internal structures so that a dynamic analysis model can be constructed.. Detailed drawings should also be included for rebar, liner, liner anchors, columns,-bracing, areas of discontinuity (excluding penetrations) such as dome-wall or dome-ring girder-wall, and wall base slab.

3.

Detailed structural drawingt of footings, basemats and piles (if applicable).

4.

Equipment location s.trrang(ment) drawings, center of gravity, and mass,

information (including mass moment of inertia) for major heavy equipment such'as reactor vessel, steam generator, tanks, cranes, condensers, steam drums, etc.

If the reactor coolant loop was coupled with the structure in the analysis, provide the simp 1.ified reactor coolant loop model (e.g.,

computer input listing and input descriptions) if available; otherwise, supply mass and mass location 'information.

5.

If the seismic reanalysis of the containment structure has been performed, provide the model-(mass properties, member stiffnesses, soil stiffnesses if applicable, etc.) used and the results.

l l

l l

w

- =

+y y

,_e.,.

-w-

-#7%94y,,

pp

...,c-

%-,a,

  • eay

- +

e

,nw.

e

=w-,

,,w, w,..

y 9, - - - _,.

p-g

5 ENCLOSURE 2 4

The following information is required for the load combination Topic III-7.8 and Wind and Tornado Loadings, Topic.III-2 Containment (Reactor Building) Structure Drawing index including titles (or' descriptions) and corresponding 1.

drawing numbers.

Layout and structural drawings with structural information on the

-2.

Detailed. drawings should also be. included containment and,its support.

for rebar, liner, liner anchors, columns, bracing, areas of -discontinuity (excluding' penetrations) such as dome-wall or dome-ring girder-wall, and wall-base slab.

3.

Detailed structural drawings of footings, basemats and piles (if-applicable).

~

All Other Safety-Related Structures Structural drawings with sufficient detail to determine the structural 1.

elements and structural systems -employed in the design of your plant-including those. relied on to resist tornado loads -(horizcntal wind and pressure differential).

t

_ Equipment location drawings and mass information for heavy equipment.

2.

b i

l i

t l

j..

t I

i

+

.v

---n.

.e

-n

.rm-en,,

,,-n

,ww-.

+w+.,.e

-s.-,

g-,m r-